You are on page 1of 2

TENSILE TEST REPORT

CUSTOMER NAME & ADDRESS: Work order CMSS/18/659


Test Report No CMSS/TT/18/503
ENERTECH ENGINEERING Date of Receipt of test Item 22-05-2018
PVT.LTD Date of testing 30-05-2018
PLOT#66 TO 77,PHASE-III,
Material EN 755 Gr.6005-T6
IDA,CHERLAPALLY,R.R.DIST,
Sample Description 4010 Al. Door Section
HYDERABAD-51. T.S. INDIA.
4010 Al. Door Section
Identification of the sample
SSQAG/4010/M
Test procedure ASTM-B-557-2015
MACHINE DETAILS
Name of the machine ADT-400KN CALIBRATED DATE 05-08-2017
S.NO. 475-2017 NEXT DUE DATE 04-08-2018

TEST DETAILS
Initial & Final parameters Observed data Specified Values
Specimen type FLAT Ultimate load( kN) 8.08
Initial Width in (mm) 13.36 UTS (N/mm2 ) 267.606 250 Min
Specimen Thickness(mm) 2.26 Elongation (%) 6.8 6 Min
2
Cross sectional area(mm ) 30.19 0.2%Proof Stress( N/mm2) 254.358 200 Min
original gauge length(mm) 49.83 0.2%Proof Load( kN) 7.68
final gauge length (mm) 53.20
Extensometer (GL) 25

Result: The test results conforms to the above specification EN 755 Gr.6005-T6 Condition
Note: Attached Load Vs displacement & Stress Vs Strain with 0.2%proof line Curve in Annexure A

Verified by Witnessed by for CRYSTAL METALLURGICAL SERVICES & SOLUTIONS

Authorized Signature
P.NAVEEN KUMAR
Format No CMSS/FM/48D(TT)
Technical Manager
Rev No.00: DT; 10-08-2017

Page2 of 2
ANNEXURE –A
Report No: CMSS/TT/18/503; Dated: 30-05-2018
Identification of the sample: 4010 Al. Door Section SSQAG/4010/M

Fig 1: Load(kN) Vs Displacement (mm), & Stress (N/mm2) Vs Strain with 0.2% proof line

for CRYSTAL METALLURGICAL SERVICES & SOLUTIONS

Authorized Signature

P.NAVEEN KUMAR
Technical Manager

Page2 of 2