You are on page 1of 1

TENSILE TEST REPORT

CUSTOMER NAME & ADDRESS: Work order CMSS/19/0600


Test Report No CMSS/TT19/003
Date of Receipt of test Item 09-04-2019
Date of testing 09-04-2019
CMR IT CAMPUS
KANDLAKOYA Material Aluminium alloy with 4%SIC
Sample Description Casted Al Alloy
Identification of the sample Aluminium alloy with 4%SIC
Test procedure ASTM B 557-15
Machine details /Exp date ADT-400KN/04-08-2019

TEST DETAILS
Initial & Final parameters Observed data
Specimen type Round Ultimate load( kN) 11.32
Initial Diameter in (mm) 12.24 UTS (MPa ) 96.20
Final Diameter (mm) 12.16 Elongation (%) 2.32
Cross sectional area(mm2) 117.67 Yield Stress (MPa) --
Original Gauge Length (mm) 50.01 Yield Load ( kN) --
Final Gauge Length (mm) 51.17
Extensometer (GL) 25.00

Results & Observations: The sample has failed before attaining the yield load because of porosity in
the material

Verified by Witnessed by for CRYSTAL METALLURGICAL SERVICES & SOLUTIONS

Authorized Signature
P.NAVEEN KUMAR
Format No CMSS/FM/48D(TT)
Technical Manager
Rev No.00: DT; 10-08-2017

Page 1 of 1