MC-LF-04-03

ANALYTICAL PROCEDURE USED: MCL/001, MCL/006 PREPARATION PROCEDURE USED:SAM. PREP.001

REFERENCE MATERIAL USED: AMIS 0388 AND INHOUSE QC

REPORT OF ANALYSIS TO AJ DIAMOND


DISPATCH NO: REPORT NUMBER D18408-D18409 DATE RECEIVED 06-May
CUSTOMER NAME: RIAAN BOTHA 082 552 1471 MATERIAL TYPE: Silica
ajdiamonds7@gmail.com WAYBILL NUMBER:

(*Part of SANAS Accreditation )


CHEMICAL ANALYSIS

Fire Assay Wet Chem ICP calc ICP ICP Wet Chem ICP NCS Fire Assay
ELEMENTS
*4E PGM *Cr2O3 *FeO Cr:Fe SiO2 Al2O3 Mn P S Au
SAMPLE ID SAMPLE DATE LAB ID Dry Masskg g/t % % calc % % % % % %
SITE 1(BLESBOK) 05-May D18408 4.40 1.38 0.00 73.38
SITE2(WITPOORT) 05-May D18409 0.60 0.80 0.00 91.94

Declaration
We, Metchem Laboratory, hereby certify that, for the product as described above,
1.Metchem Laboratory is not responsible for the sampling activity related to this sample
2. The measurements are traceable to national and international standards.
3. The results relate only to the items tested and are reported on the dry basis.
4 . Control Charts for the QC's are updated and kept for each sample analysed by the laboratory
5. Any deviations outside the estimated uncertainty on each element analysed and reported will be stated. T0731
6.Any opinions and interpretations expressed herein are outside the scope of sanas accreditation.
Approval of certificate

Patrick Nkobongo Patrick Nkobongo 07-May-21


Technical Signatory Laboratory Manager/Chemist