You are on page 1of 2

ACCREDITED TEST LABORATORY BY PERUVIAN

ACCREDITATION BODY INACAL-DA WITH REGISTER N° LE-


031

Inspectorate Services Perú S.A.C.


Av. Elmer Faucett N° 444, Prov. Const. del Callao, Perú

Test Report with Official Value N° LMP2018393


CLIENT INFORMATION
NEXA RESOURCES CAJAMARQUILLA S.A.
Car. Central Nro. 9.5 Cajamarquilla,Lurigancho,

JOB INFORMATION METHOD INFORMATION


Job Number LMP2018393 METHOD CODE METHOD DESCRIPTION
Report Date 12/Mar/2020 ISP-757 Uniform method of measurement of the density of bulk
cargoes. IMSBC Code MSC/Circ.908: 2018
Commodity Zinc Concentrate
ISP-758 Alternative or shipboard test method to be used or the
Vessel determination of the angle of repose when the tilting box is
Sampling Date 11/Mar/2020 not available. IMSC Code Appendix 2, Subsection 2.2:
2018
Sample Quantity 1
Job Type FMP/TML Test ISP-759 Flow Table Test procedure. IMSC Code Appendix 2,
Subsection 1.1: 2018. Copper, lead, and zinc sulfide
Sample Presentation Plastic envelopes concentrates — Determination of transportable moisture
limits — Flow-table method. ISO 12742:2007 6.2.3
Sample Source Carahuacra
Tamping pressure. Table 2
Samples Sealed
Date Received 11/Mar/2020
Analysis Start Date 11/Mar/2020
Reporting Lab

COMMENTS AUTHORIZED SIGNATURE


* Indicated methods have not been accredited by INACAL-DA
The test results are only valid for the samples tested and must not be used as a certification in accordance
with product standards or as a certificate of the quality system of the entity that produces it. The company is
not responsible for the origin or source from which the samples have been taken.
Bureau Veritas does not accept responsibility for samples left at the laboratory
after 90 days without prior written instructions for sample storage or return.
The Commodity information, client information, vessel name, Weight / Unit, Lot Reference, sample sealed and Raul Enrique Laura, Eng. Laboratory
sample sources have been provided by the client. The Laboratory is not responsible when the information Head. CIP No 139335
provided by the client may affect the validity of the results.

The sample was taken and sent by INSPECTORATE SERVICES PERU S.A.C. from Perubar S.A. Av. Nestor
Gambeta 983 - Callao. NTP-ISO 12743:2017, F-OMM-008. (OPS-020332/20-EMB)
Reporting Lab: Miller Prep Site: Street Juan Miller 249, Urb. Industrial la Chalaca Callao.

All services are rendered in accordance with Bureau Veritas' s General Terms and Conditions of Business, Page 1 of 2
available on request or at http://www.bureauveritas.com/wps/wcm/connect/bv_com/group/home/about-us/our-
business/commodities/about-us/inspectorate-terms-and-conditions
ACCREDITED TEST LABORATORY BY PERUVIAN
ACCREDITATION BODY INACAL-DA WITH REGISTER N° LE-
031

Inspectorate Services Perú S.A.C.


Av. Elmer Faucett N° 444, Prov. Const. del Callao, Perú

Test Report with Official Value N° LMP2018393


Job Number LMP2018393
Report Date 12/Mar/2020
Commodity Zinc Concentrate

Method ISP-757 ISP-758 ISP-759 ISP-759


Analyte Stowage Angle of TML FMP
Factor Repose
Sample Lot Ref Sample State Weight/Unit M³/t ° % %
ID
001 IMO 2,366.510 As Received 0.48 41.08 8.28 9.20
TMH

All services are rendered in accordance with Bureau Veritas' s General Terms and Conditions of Business, Page 2 of 2
available on request or at http://www.bureauveritas.com/wps/wcm/connect/bv_com/group/home/about-us/our-
business/commodities/about-us/inspectorate-terms-and-conditions

You might also like