Professional Documents
Culture Documents
PT PETROLAB SERVICES
Jl. Jend Sudirman No. 874 Komp. UT Stalkuda Balikpapan 76114
Telp 0542-762873 fax. 0542-765019; petrolab@cbn.net.id; www.petrolab.co.id No. 23174/BPN/11/21
Company Name : PT. BORNEO ENERGI GEMILANG Unit Model : NOT GIVEN Oil Matrix : MOBIL DTE 846
To Customer : PT. BORNEO ENERGI GEMILANG Unit Number : 2 Serial Number :
Address : Component : TURBIN Make/Brand : NOT GIVEN
Location : Component Matrix : TB S Sample From :
Physical Test Unit Method Test Value Min | Max Min | Max
Visc@40C cSt ASTM D7279-20 38.2 | 46.6 33.9 | 50.9
Visc@100C cSt ASTM D7279-20 5.58 | 6.82 4.96 | 7.44
Visccosity Index *) - ASTM D2270-10e1
Contaminant
Water Content By KF ppm ASTM D6304 59 1000 2000
Others Parameters
4 um Particles/ml 7165
6 um Particles/ml 1712
14 um Particles/ml 48
ISO CODE ISO 4406-17 20/18/13 / B /16/13 0/18/15
Source of Abnormality
HASIL ANALISA ATTENTION. Indikasi tingkat kebersihan pelumas (Cleanliness) rendah, masih dalam batas toleransi.
Action to be Taken
Cek seal, oil filler plug, inspection plug, breather pastikan dalam kondisi baik. Perhatikan kebersihan tool sampling dan cara pengambilan sampel. Lanjutkan sampling pada
jadwal service berikutnya.
Note:
- Data analisa hanya berlaku untuk sample yang di uji di laboratorium PT. Petrolab Services
- Report tidak boleh digandakan tanpa persetujuan tertulis dari laboratorium
- Laboratorium PT. Petrolab Services tidak bertanggung jawab terhadap kegiatan sampling
Disetujui