Professional Documents
Culture Documents
Electrical Drawing
00
Document realized with version : 2019.0.5.114
1 2 3 4 5 6 7 8 9 10
-Q1
N 02-1
L1 Red 02-1
L2 Blue
L3 Yellow
PE 02-1
-CB1
-CB2
-CB5
6A
16A
10A
-CB3
6A
Black
Red
8
02-1
10
A1
-T1 A2
24V AC
4A
-C2 -C3
A2 24V 0V A1
1
A1 L1 L2 L3
RS 1
209-6384
2
-C1 N
Injection Brake A2 T1 T2 T3
C
Module
U1
2.2kW 9 9
02-1
V1
D
95
-OL/2
-CB4
10 -OL/1
96
2
02-1
-M3 -M5
M 0.18kW
705rpm
M 0.75kW
1395rpm
-M4
0.18kW M
1320rpm
Rear Front
Blade Motor Blade Motor Waste Conveyor
0V
02-1
REVISION
Electrical Drawing 0
REV. DATE NAME CHANGES SCHEME
CONTRACT:
LOCATION:
+L1 Main electrical closet 01
Document realized with version : 2019.0.5.114
1 2 3 4 5 6 7 8 9 10
N
01-10 03-1
L1
01-10 03-1
PE
01-10 03-1
03-1
Panel
0V E-STOP
01-10
-S3
1 2
2
01-10
RESET
-S8
4 12 16
-CR1
XPS-AL 4 6 12
-S1
-S2
6
A2 L1 L2 L3 13 31
5 7
Stop Start
A1 T1 T2 T3 14 32
7 13
8 9
4 5
-S4
-S5
-S6
-S7
4 4 4
3 4
8
01-10 03-1
9
01-10
REVISION
Electrical Drawing 0
REV. DATE NAME CHANGES SCHEME
CONTRACT:
LOCATION:
+L1 Main electrical closet 02
Document realized with version : 2019.0.5.114
1 2 3 4 5 6 7 8 9 10
N
02-10
L1
02-10
PE
02-10
-CB6
-CB7
6A
6A
-R1 2.2Kohm
0.18kW 0.18kW
-VFD1 -VFD2
COM Blue Red COM
Yellow Yellow
AI1 AI1
1 +24 Blue +24
LI1 +5V LI1 3
2 4
13 A1 0 0 A1 13
-K9 -K10
5 6
14 A2 A2 14
-M1 -M2
M 0.18kW M 0.18kW
8
02-10
0
02-10
REVISION
Electrical Drawing 0
REV. DATE NAME CHANGES SCHEME
CONTRACT:
LOCATION:
+L1+New electrical closet 03
Document realized with version : 2019.0.5.114