You are on page 1of 1

SKY WALK

(B10)
ITEM ITEM U/P T/P
UNIT QTY.
No. DESCRIPTION LE LE

1 PLUMBING FIXTURES
a Supply,install ,connect ,plumbing fixtures trim and accessories complete
including mixers, faucets, water supplies connections , drainage
connections, stop angle valves, ablution faucets, ..etc. All as per specified To be out of
by architect and as shown on drawings. scope as per
owner
Lavatory No. 14 requirements
Water Closet No. 10
Urinal No. 2

2 PIPING SYSTEM
a DOMESTIC COLD WATER PIPING SYSTEM
Supply, install, connect, and test of(PPR) piping(inner diameter/PN 16)
systems for Domestic cold water systems complete with water hammer
arrestors, including fittings , supports , hangars and fittings and all other
accessories and as shown on drawings.
- 15 mm diam . Piping M. 40 50 2,000
- 20 mm diam . Piping M. 120 60 7,200
- 25 mm diam . Piping M. 20 70 1,400
- 32 mm diam . Piping M. 85 80 6,800
- 40 mm diam . Piping M. 52 90 4,680
- 50 mm diam . Piping M. 12 100 1,200
0
b DOMESTIC HOT WATER PIPING WITH INSULATION 0
Supply, install, connect, and test of (PPR composit layer type) piping(inner 0
diameter/PN20) systems for Domestic hot water systems complete with
- 15 mm diam . Piping M. 35 50 1,750
water hammer arrestors, including fittings , supports , hangars, insulation ,
- 20 mm diam
aluminium . Piping
covers, balancing valves,expansion connections and fittings M. 12 60 720
- 25 mm diam . Piping M. 6 70 420
0
3 DRAINAGE ABOVEGROUND PIPING SYSTEM 0
Supply, install, connect and test all soil, waste and vent (UPVC) 0
(PN.10/inner diameter) vertical & horizontal aboveground piping system
- 50 mm diam.Piping M. 60 70 4,200 DIN 8061-8062
from all plumbing fixtures to outside the building complete including clean
-outs
75 mm diam.Piping
fittings, roof vent caps, couplings, supports, insulation and sound M. 150 85 12,750 DIN 8061-8062
- 100 mm diam.Piping M. 45 120 5,400 DIN 8061-8062
0
4 HEATING SYSTEM 0
INDIVIDUAL ELECTRICAL WATER HEATER 0
Supply, install, connect, test and commissioning of individual storage 0
electric
E.W.H (water heater
60 Liter ) , including glass lined tank, heating coil ,controller, No. 4 300 1,200
thermostatic controller , sacrificial rod, isolating valves , relief valves ,
check valves , Expansion tank ,pipes, fittings, flanges,and all other 0
5 ROOF VENT CAP 0
Supply, install, connect and test of roof vent cap cast iron type.including 0
all
75mmnecessary required for the installation.all as specified in specifications
Dia. R.V.C No. 12 250 3,000
and as shown on drawing.
100mm Dia. R.V.C No. 2 300 600
0
6 ROOF DRAINS 0
-Side Roof Drain 75 mm diam. No. 10 250 2,500
7 WALL CLEAN OUT 0
- 75 mm diam. No. 6 150 900
8 FLOOR CLEAN OUT 0
- 75 mm diam. No. 2 250 500
9 FLOOR DRAIN 0
-50 mm diam. No. 16 250 4,000
0
10 CONTROL VALVES 0

Supply, install, connect and test of Isolation gate valves including but not
limited to fittings, unions, dismantle joints and all necessary required for 0
the installation. All as specified in specifications and as shown on drawing.

a GATE VALVES 0
- 20 mm diam. No. 10 100 1,000
- 32 mm diam. No. 4 120 480
11 AUTOMATIC AIR VENT 0

Supply, install, connect and test of automatic air vent completet including
but not limited to fittings and all necessary required for the installation . all No. 3 120 360
as specified in specifications and as shown on drawings.

0
12 HB (Hose Bibbs) 0

Supply, install, connect and test of Hose Bibb complet including but not
limited to isolating valve, fittings and all necessary required for the No. 1 150 150
installation . all as specified in specifications and as shown on drawings.

TOTAL 63,210

REV.: 00 DATE: July 2022 Page 1 of BOQ