SERVICE REPORT
Date : 17-Jul-23
No : ________________
Technician
Name : _____Maryadi. M.EL Transfer to Repair/Save/Install1
Phone : ________________ General Check Regular Check/Preventive2
Email : ________________ Repair3
Asset Data
GEA SMALL CHILLE
Status RO / RN / S / I Voltage1,3 220V
Manufacturer GEA Frequency 1,3
50Hz
Model/Source FD30 Power1,3 800 W
S/N AB1156207499000518
Category Showcase Location Af.1 Equipment Condition: Bad ( Fault Compressor System )
Complain & Problem
No Cooling
Solution/Replacement
General Cheked, Found Compressor Fault ( Off ), Thermostat Fault, PTC, Overload Down,Fan cooler
ABASSA TECHNIC
Apa Bae Bisa
compresso
machine serial number fan cooler