You are on page 1of 3

enta100 GD

LAYOUT
Counter weight rear Machine room plan
without traction machine

Shaft Vertical Section


Machine room>=2500

Machine room depth


M.C.B

Front Min. Extn. 1000


Controller
Overhead height

Machine room width

Lift Plan

Shaft width
Travel height

Shaft depth
Car depth

Car width
COP

Door width
Pit depth

Above illustration is of
Automatic Center Opening
10
enta100 GD

TECHNICAL SPECIFICATIONS
RATED PAX DOOR DOOR WIDTH CAR WIDTH CAR DEPTH SHAFT WIDTH SHAFT DEPTH
LOAD (KG) CAPACITY TYPE (DW) (MM) (CW) (MM) (CD) (MM) MIN MAX (MM) MIN MAX (MM)

ACO 700 1100 800 1550 1915 1350 1600


340 5
ATO 700 1100 800 1400 1915 1425 1675

ACO 700 1000 1000 1570 1865 1375 NA


408 6
ATO 700 1000 1000 1510 1865 1450 NA

ACO 700 1250 1050 1550 2065 1600 1850

544 8 ACO 800 1350 1000 1750 2165 1550 1800

ATO 800 1200 1100 1500 2015 1725 1975

 In case of recess mounted landing doors, shaft depth is reduced by 50 mm


 Machine room front extension is mandatory. In case of side counterweight customer has to provide left/right side extension as shown in GAD

GENERAL PLANNING DATA


Abbreviations:
FEATURES DESCRIPTION CW: Car width, CD: Car depth, CH: Car height (Car inside clear height),
DW: Door width, DH: Door height, SW: Shaft width, SD: Shaft depth, ACO:
Automatic center opening, ATO: Automatic telescopic opening, FTFH:
Car inside clear height (CH) 2100 Floor to floor height, TH: Travel height, OH: Overhead, PD: Pit depth, MR:
Machine room, MRW: Machine room width, MRD: Machine room depth,
2000 MRH: Machine room height
Standard door height

Minimum pit height 1400

Minimum overhead height 4200

Minimum machine room height 2200

Minimum floor height 2600

*All dimensions in mm

11
enta100 GD

FUNCTION LIST
STANDARD/
CATEGORY NO. FUNCTION
OPTION

1 ACVVF drive S

2 Automatic operation for car fan & light S

Enhanced Car
Functions 3 Full load by-pass S

4 Simplex down collective control S

5 Simplex full collective selective control O

6 Alarm button in COP with battery back-up S

7 Emergency light in COP S

8 Light curtain for car door S


Safety and
Emergency 9 Overload function with audio-visual indication in COP S
Functions
10 Phase failure and phase reversal protection S

11 Auto Rescue Device (ARD) in case of power failure O

12 Fireman Operation O

13 Door open and Door close buttons in COP S


Human Machine
Interface
14 Voice announcement system (VAS) (English language only) O

Monitoring and
15 3 way intercom O
Tele-service

Group/Duplex control 16 Duplex full collective selective control O

Note: S – Standard O – Optional

All product specifications and parameters specified in this brochure are recorded according to the data valid at the time it was prepared. TK Elevator (India) is entitled to,
upon its sole discretion, adjust the relevant technical specifications and / or other parameters according to the actual production situation. Please kindly contact the local
representative or the nearest sales branch of TK Elevator when purchasing our products. TK Elevator (India) reserves the sale and exclusive interpretation right on any and
all content in this brochure.