300 kW to 1200 kW
Enhanced Design and Improved Efficiency
Enabling Tomorrow’s
CRITICAL EDGE
INFRASTRUCTURE
2
Liebert® eXLTM S1
300 kW to 1200 kW
Enhanced Design and Improved Efficiency
Liebert® eXLTM the New T-free Monolithic UPS Generation Delivering Secure
Power and Maximized Energy Saving
Liebert® eXLTM, the new generation of Liebert® eXLTM can operate with both
HIGHLIGHTS 80-NET UPS, delivers unsurpassed standard VRLA and new Li-ion batteries
performance to medium-large data thus adapting to all possible
• Extraordinary double conversion centers as a result of proven track requirements in terms of runtime, life
efficiency up to 97% record, successes, a reliable large expectancy and TCO, and showing
installed base and more than 10 years extreme flexibility.
• Intelligent ECO mode efficiency of acquired experience with the
above 99% 80-NETtechnology. Furthermore, its higher power density
in a minimum footprint optimizes the
• Intelligent paralleling feature The new Liebert® eXLTM is a monolithic availability of IT space and reduces
optimizes efficiency at partial product that features a transformer-free related costs.
load design with a full IGBT three-level
topology, providing extraordinary Liebert® eXLTM, available from 100 to
• Maximized active power at unity features including a double conversion 1200 kW, delivers secure power while
power factor efficiency of up to 97% plus intelligent providing first class load protection
paralleling to optimize efficiency at and maximum energy saving for
• Compact footprint for optimum partial load, thus achieving superior missioncritical applications.
space utilization running cost savings as well as
reduced TCO and CO2 emissions.
• Backward compatibility with
previous 80-NET generation
>2.5
GW
WORLDWIDE
3
Liebert® eXLTM S1
300 kW to 1200 kW
Enhanced Design and Improved Efficiency
100%
- THDi < 3% protection, cabling and transformers.
20
kVA
• Automatic output power upgrade Flexibility and Compatibility Cosφ 1
of up to +10% Liebert® eXLTM can be fully adapted to 0
25 50 75 100% kW
meet diverse system requirements in
kVA
20
• Output PF diagram symmetrical terms of power capacity and redun-
1 00 %
respect to zero dancy allowing for different system 40
designs, thus ensuring maximum Cosφ 0.9
• Three and four wire electrical flexibility: 60
compatibility Cosφ 0.8
• Output Power Factor up to 1 80
• Centralized and distributed Cosφ 0.5
parallel capabilities • Output Power Factor diagram 100
10 0 %
kVA
symmetrical respect to zero
• Seismic compliance Lagging
• Permanent 100% kVA - no derating
with any load (lagging or leading)
4
Liebert® eXLTM S1
300 kW to 1200 kW
Enhanced Design and Improved Efficiency
Improved Efficiency
Liebert® eXLTM delivers an outstanding Liebert® eXLTM levels of efficiency and Fast transfer technology ensures the
double conversion efficiency of up to consequent electricity cost savings quickest response time under various
97%, consequently reducing operating can be attribuited to: conditions:
costs and energy dissipation (kW) to a
minimum. This significantly minimizes • Latest generation IGBT • Network fault (voltage variation,
the consumption of the cooling • Adoption of a three-level NPC2 high/low impedance mains failures)
system, providing an overall TCO topology for both rectifier and
reduction and rapid payback time. inverter • Load fault (short circuit downstream
• DC controlled fan speed of the UPS)
Furthermore, through its intelligent • Intelligent paralleling mode
ECO mode efficiency and the intelli- • Advanced digital technology and fast • Type of load connected (PDU
gent paralleling feature Liebert® eXLTM transfer transformer)
can optimize efficiency even at partial
load achieving additional superior cost The seamless activation of Liebert® The unit is able to discriminate
savings. eXLTM functioning modes ensures the between various types of interferences
highest level of efficiency without and rapidly respond, while at the same
compromising power quality and time ensuring compatibility with
availability. downstream equipment such as
servers, transformers, STS or
mechanical loads.
Manual Bypass
Batteries
LOAD
Batteries
5
Liebert® eXLTM S1
300 kW to 1200 kW
Enhanced Design and Improved Efficiency
Intelligent Paralleling
Liebert® eXLTM Intelligent Paralleling
Feature
33%
Four units at 33% load each = 96%
efficiency.
65%
Liebert EXL Intelligent Paralleling:
two units at 65% load each = 96.8%
efficiency
6
Liebert® eXLTM S1
300 kW to 1200 kW
Enhanced Design and Improved Efficiency
Parallel Configurations
The Liebert® eXLTM can be connected with up to 8 units in parallel, where single units can be serviced while the remaining
units continue to power the load. A Liebert® eXLTM unit continues to operate even while it’s being upgraded to a parallel
system due to the upgrade occurring via software settings. Furthermore, Liebert® eXLTM is backward compatible with the
previous 80-NET generation, so as to facilitate any legacy system power upgrade. Liebert® eXLTM can support both distrib-
uted and centralized parallel configurations providing maximum energy saving via double conversion and intelligent ECO
mode, allowing to operate with a system efficiency of up to 99%.
Load
7
Liebert® eXLTM S1
300 kW to 1200 kW
Enhanced Design and Improved Efficiency
Measurements
Voltage, current and frequency values
of each internal functional block.
8
Liebert® eXLTM S1
300 kW to 1200 kW
Enhanced Design and Improved Efficiency
Reduced TCO
97% CO2
maximize the number of racks and
servers housed in their data center,
thus granting more space for IT
equipment.
Double Conversion 950 tons The Liebert® eXLTM technology, has
of CO2 saved every year brought extraordinary benefits in terms
of:
• Reduced TCO
9
Liebert® eXLTM S1
300 kW to 1200 kW
Enhanced Design and Improved Efficiency
10
Liebert® eXLTM S1
300 kW to 1200 kW
Enhanced Design and Improved Efficiency
• High security access with separate Liebert® Nform™ will monitor the Vertiv’s Trellis platform is a
password levels for users and Liebert® eXLTM via SNMP protocol. realtime infrastructure optimization
service engineers Authenticated alarm management, platform that enables the unified
trend analysis and event notification management of data centre IT
• User-friendly graphical interface delivers a comprehensive monitoring and facilities infrastructure.
solution. Available in a variety of
• Single-line mimic diagram showing versions to suit anything from small The Trellis platform software can
system status computer rooms to multiple location manage capacity, track inventory,
distributed IT networks, Liebert Nform plan changes, visualize configura-
• Dedicated warning/fault and event enables: tions, analyze and calculate energy
log page used to monitor USP usage, and optimize cooling and
status and important events • Condition based system state power equipment.
recording
• Dedicated measurements page for The Trellis platform monitors the
all UPS internal functional blocks • Alarm event exporting to disk data center, providing a thorough
understanding of system depend-
Hardware Connectivity • SMTP email encies to help IT and facilities
organizations keep the data center
Liebert® eXLTM allows for the • Execution of external program running at peak performance. This
monitoring and control of networked unified and complete solution,
UPS, through different protocol • Shut down clients delivers the power to see the real
options: situation in your data center, make
Liebert SiteScan® is a centralized site the right decision and take action
• The integration of UPS with Building monitoring system which ensures with confidence.
Monitoring and Automation maximum visibility and availability of
Systems via MODBUS RTU, MOD critical operations. Liebert SiteScan
BUS/TCP or JBUS protocols Web allows users to virtually monitor
and control any piece of critical
• The integration of UPS in Network support equipment. Its features include
Management Systems through real-time monitoring and control, data
SNMP protocol analysis, trend reporting, and event
management.
• Two slots for additional connectivity
cards are available for specific
protocol requirements.
11
Liebert® eXLTM S1
300 kW to 1200 kW
Enhanced Design and Improved Efficiency
Customer Experience Center to 1.2 MVA of capacity. Testing Our Customer Experience Center
includes individual modules, as well offers three validation experiences:
Vertiv™ state-of-the-art Customer as complete power systems, with the • Demo - carried out on new products
Experience Center located in added possibility of the customer’s to demonstrate UPS performance
Castel Guelfo (Bologna - Italy), switchgear support systems being • Standard - validation test showing
enables our customers to connected, thus guaranteeing smooth, UPS standard technical perfor
experience first-hand a wide rapid installation and commissioning of mances in compliance with UPS
variety of data center large power systems. catalogue and IEC 62040-3
technologies, supported by standards
constant consultation from R&D Testing is also customized based on • Customized - session tailored to
and engineering specialists. the complexity, size and number of validating customer’s specific
UPS components in the configuration. technical performance needs.
12
Liebert® eXLTM S1
300 kW to 1200 kW
Enhanced Design and Improved Efficiency
7
3 1 5
UPS
Liebert® Trinergy™ Cube 3.4 MW 2
•
the industry: 98.5%
• Unprecedented levels of installation
flexibility
• Hot scalability up to 3.4 MW.
4
Liebert® EXL 1200 kW
•
Remote Diagnostics
of up to 97% plus intelligent paralleling Vertiv™ LIFE™ Services
• Remote Diagnostic and
above 99% Preventive Monitoring
• Enhanced energy density and compact With Vertiv LIFE Services
footprint you will benefit from:
• Uptime assurance
• Parallel system configuration up to 8
units with both centralized and • First time fix rate
distributed parallel capabilities.
• Proactive analysis
centers.
7 DC Power
14