N Control Recommended Control Jan- Feb- Mar- Apr- May- Jul- Aug- Sep- Oct- Nov- Dec-

SEG Jun-23
o Measure Measures 23 23 23 23 23 23 23 23 23 23 23
To fix loose muffles, leaky To be
exhausts, and rusty parts. replace
d with
To install enclosure to the new
Engineering
engine/motor. one
Regular maintenance and
servicing equipment.
Administrativ Duration of exposure (less than
e 3 hours 10 minutes per day.
PHP (Personal Hearing
Grass
Protector)
1 Cutter PHP
Operator Inspection and maintenance of
PHP.
Audiometric
testing Audiometric testing annually
program
Training Annual training program
Signage “HEARING
Hearing PROTECTION ZONE”.
protection
zone To indicate noise level to be
shown on the grass cutter.
Administrativ
e
Adequate maintenance
Training Annual training program
Tractor
2 Signage “HEARING
Driver Hearing PROTECTION ZONE”.
protection
zone To indicate noise level to be
shown on the engine tractor.
N Control Recommended Control Jan- Feb- Mar- Apr- May- Jul- Aug- Sep- Oct- Nov- Dec-
SEG Jun-23
o Measure Measures 23 23 23 23 23 23 23 23 23 23 23
To fix loose muffles, leaky To be
exhausts, and rusty parts. replace
To install silencer or muffler to d with
Engineering the engine exhaust outlet or new
pipe connection. one

Regular maintenance and


servicing equipment.
Administrativ Duration of exposure (less than
e 2 hours 31 minutes per day.
PHP (Personal Hearing
Fogging Protector)
3
Operator PHP
Inspection and maintenance of
PHP.
Audiometric
testing Audiometric testing annually
program
Training Annual training program
Signage “HEARING
Hearing PROTECTION ZONE”.
protection
zone To indicate noise level to be
shown on the fogging machine.

N Control Recommended Control Jan- Feb- Mar- Apr- May- Jul- Aug- Sep- Oct- Nov- Dec-
SEG Jun-23
o Measure Measures 23 23 23 23 23 23 23 23 23 23 23
To fix loose muffles, leaky
exhausts, and rusty parts.
To enclose the motor in a To be
sound proofing cover with replace
Engineering sound absorbing material and d with
ventilated. new
one
To substitute with battery-
operated earth auger which
produce lower noise.
Administrativ Duration of exposure (less than
Earth e 2 hours 31 minutes per day.
4 Auger PHP (Personal Hearing
Operator Protector)
PHP
Inspection and maintenance of
PHP.
Audiometric
testing Audiometric testing annually
program
Training Annual training program
Signage “HEARING
Hearing PROTECTION ZONE”.
protection
zone To indicate noise level to be
shown on the earth auger
N Control Recommended Control Jan- Feb- Mar- Apr- May- Jun- Jul- Aug- Sep- Oct- Nov- Dec-
SEG
o Measure Measures 23 23 23 23 23 23 23 23 23 23 23 23
Air Compressor
To do general maintenance by
checking the belt tension,
lubricating and regularly
changing filters and oil.
To enclose the motor in a sound
proofing cabinet with sound
absorbing panels and
Engineering
ventilated.
To install rubber grommet on
the motor mounting bracket on
the frame.
Mechani
5 Impact wrench
c
To reduce the pressure in the
air line by using a regulator to
the minimum needed.
Administrativ
e
Adequate maintenance
Training Annual training program
Signage “HEARING
PROTECTION ZONE”.
Hearing
protection To indicate noise level to be
zone shown on the power tools,
impact wrench, and air
compressor.