DOC–JL Burner
DOC-JL Burner
P-SPEC SHEET 3 DOC WFB 10 PT_Layout 1 10/19/11 3:47 PM Page 2
DOC-JL Burner
20.0 6.0
18.0 5.0
16.0 4.0
14.0 3.0
12.0 2.0
10.0 1.0
With proper placement, Praxair’s DOC-JL burners Length Width-Min Width-Max
minimize alkali volatilization and particulate formation 8.0 0.0
from the glass melt which significantly reduce furnace 4 5 6 7 8 9 10 11
refractory corrosion and promote longer furnace life. Input rate, MMBtu/h
In addition, the burner can operate with a variety of Figure 2. DOC-JL flame length and width as a function
gaseous, liquid, and solid fuels. of firing rate
Benefits Praxair understands the impact of oxygen supply
No burner cooling required parameters (including pressure and purity) on com-
• Minimal maintenance bustion system design, performance, and cost. As
your oxygen supplier, we are uniquely positioned to
• Oxygen staging allows:
work with your engineers and procurement special-
– flame stability ists to design a fully integrated package that meets
– flame length and temperature profile adjustments your specific oxy-fuel combustion needs.
– atmosphere stratification control
– Ultra-low NOx operation
*(US Patents 5267850, 5411395, 5449286, 5601425,
• Multi-fuel burner 5814125, 5823762, 5931654, 6096261, 6125133,
• Volatilization control 6139310, 6132204, 6142764, 6394790, 6171544)