Professional Documents
Culture Documents
34' 3'-6"
DESIGN NOTES:
1. GRADE OF CONCRETE CONFIRMING TO IS
456:2000 IS :
NOTES:
1. ALL DIMENSIONS ARE IN FEET AND INCHES,
UNLESS OTHERWISE MENTIONED.
2. DIMENSIONS ARE NOT TO BE SCALED. ONLY
WRITTEN DIMENSIONS ARE TO BE FOLLOWED.
3. THIS DRAWING SHALL BE READ IN
CONJUNCTION WITH RELEVANT
ARCHITECTURAL, STRUCTURAL AND
ELECTRICAL DRAWINGS AND ALL RELEVANT
SECTIONS OF THE SPECIFICATIONS, IF
APPLICABLE.
4. ANY DISCREPANCY, ERROR OR AMBIGUITY
SHALL BE IMMEDIATELY REFERRED TO THE
ENGINEER-IN-CHARGE FOR CLARIFICATION.
.
PLINTH AREA
36'
20' WIDE ROAD 26' X 36'
54'
REVISION:
14'-6"
RELEASED FOR: DIRECTION:
INFORMATION
TENTATIVE
REVIEW
N
CONSTRUCTION
CLIENT:
G.S.REDDY
PROJECT:
RESIDENTIAL BUILDING
REVISION:
DESIGN NOTES:
1. GRADE OF CONCRETE CONFIRMING TO IS
456:2000 IS :
2. THE STRUCTURAL STEEL SHALL BE HIGH
YIELD STRENGTH DEFORMED BAR
CONFIRMING TO IS 1786:2008 IS :
3. S.B.C OF SOIL IS TAKEN AS :
4. STRUCTURE IS DESIGNED FOR:
V
NOTES:
1. ALL DIMENSIONS ARE IN FEET AND INCHES,
UNLESS OTHERWISE MENTIONED.
TOILET 2. DIMENSIONS ARE NOT TO BE SCALED. ONLY
7'0"X4'0" WRITTEN DIMENSIONS ARE TO BE FOLLOWED.
3. THIS DRAWING SHALL BE READ IN
CONJUNCTION WITH RELEVANT
ARCHITECTURAL, STRUCTURAL AND
ELECTRICAL DRAWINGS AND ALL RELEVANT
SECTIONS OF THE SPECIFICATIONS, IF
C.BED ROOM APPLICABLE.
M.BED ROOM W1
9'4"X12'0" 4. ANY DISCREPANCY, ERROR OR AMBIGUITY
SHALL BE IMMEDIATELY REFERRED TO THE
W2 11'0"X12'0" ENGINEER-IN-CHARGE FOR CLARIFICATION.
.
TOILET
V 6'6"X4'0" TOILET V
7'0"X4'0"
G.BED ROOM
11'0"X10'0"
W1
REVISION:
LIVING ROOM
13'8"X18'4" W2
KITCHEN
11'0"X8'0"
POOJA
4'0"X1'6"
RELEASED FOR: DIRECTION:
W2
LANDING
INFORMATION
UP
TENTATIVE
REVIEW
N
CONSTRUCTION
MAIN GATE
CLIENT:
G.S.REDDY
PROJECT:
RESIDENTIAL BUILDING
TITLE:
G+1 STOREY BUILDING
GATE DESIGN DRAWN CHECKED APPROVED
A.V.R A.V.R B.S.R B.S.R
DATE: 16/06/2021 SCALE: N/A
REVISION:
DESIGN NOTES:
1. GRADE OF CONCRETE CONFIRMING TO IS
456:2000 IS :
2. THE STRUCTURAL STEEL SHALL BE HIGH
YIELD STRENGTH DEFORMED BAR
BALCONY BALCONY CONFIRMING TO IS 1786:2008 IS :
3. S.B.C OF SOIL IS TAKEN AS :
11'2"X3'2" 13'10"X3'2" 4. STRUCTURE IS DESIGNED FOR:
V
NOTES:
1. ALL DIMENSIONS ARE IN FEET AND INCHES,
UNLESS OTHERWISE MENTIONED.
TOILET 2. DIMENSIONS ARE NOT TO BE SCALED. ONLY
7'0"X4'0" WRITTEN DIMENSIONS ARE TO BE FOLLOWED.
3. THIS DRAWING SHALL BE READ IN
CONJUNCTION WITH RELEVANT
ARCHITECTURAL, STRUCTURAL AND
ELECTRICAL DRAWINGS AND ALL RELEVANT
SECTIONS OF THE SPECIFICATIONS, IF
C.BED ROOM APPLICABLE.
M.BED ROOM W1 4. ANY DISCREPANCY, ERROR OR AMBIGUITY
9'4"X12'0" SHALL BE IMMEDIATELY REFERRED TO THE
W2 11'0"X12'0" ENGINEER-IN-CHARGE FOR CLARIFICATION.
.
TOILET
V 6'6"X4'0" TOILET V
7'0"X4'0"
G.BED ROOM
11'0"X10'0"
W1
REVISION:
LIVING ROOM
13'8"X18'4" W2
KITCHEN
11'0"X8'0"
POOJA
4'0"X1'6" DIRECTION:
RELEASED FOR:
W2
INFORMATION
LANDING
UP
5' WIDE CORRIDOR
TENTATIVE
REVIEW
N
CONSTRUCTION
CLIENT:
MAIN GATE
G.S.REDDY
PROJECT:
RESIDENTIAL BUILDING
TITLE:
G+1 STOREY BUILDING
GATE DESIGN DRAWN CHECKED APPROVED
A.V.R A.V.R B.S.R B.S.R
DATE: 16/06/2021 SCALE: N/A
REVISION: