You are on page 1of 3

© BHAVANAM'S C 2 C

THIS DOCUMENT SHOULD NOT BE RELIED ON


OR USED IN CIRCUMSTANCES OTHER THAN
THOSE FOR WHICH IT WAS ORIGINALLY
PREPARED AND FOR WHICH BHAVANAM C2C
WAS COMMISIONED. BHAVANAM C2C ACCEPTS
NO RESPONSIBILITY FOR THIS DOCUMENT TO
ANY OTHER PARTY OTHER THAN THE PERSON
BY WHOM IT WAS COMMISIONED.

34' 3'-6"
DESIGN NOTES:
1. GRADE OF CONCRETE CONFIRMING TO IS
456:2000 IS :

3'-6" 26' 4'-6" 2. THE STRUCTURAL STEEL SHALL BE HIGH


YIELD STRENGTH DEFORMED
CONFIRMING TO IS 1786:2008 IS :
BAR

3. S.B.C OF SOIL IS TAKEN AS :


4. STRUCTURE IS DESIGNED FOR:

NOTES:
1. ALL DIMENSIONS ARE IN FEET AND INCHES,
UNLESS OTHERWISE MENTIONED.
2. DIMENSIONS ARE NOT TO BE SCALED. ONLY
WRITTEN DIMENSIONS ARE TO BE FOLLOWED.
3. THIS DRAWING SHALL BE READ IN
CONJUNCTION WITH RELEVANT
ARCHITECTURAL, STRUCTURAL AND
ELECTRICAL DRAWINGS AND ALL RELEVANT
SECTIONS OF THE SPECIFICATIONS, IF
APPLICABLE.
4. ANY DISCREPANCY, ERROR OR AMBIGUITY
SHALL BE IMMEDIATELY REFERRED TO THE
ENGINEER-IN-CHARGE FOR CLARIFICATION.
.

PLINTH AREA

36'
20' WIDE ROAD 26' X 36'

54'
REVISION:

14'-6"
RELEASED FOR: DIRECTION:

INFORMATION
TENTATIVE
REVIEW
N
CONSTRUCTION

CLIENT:

G.S.REDDY

PROJECT:

RESIDENTIAL BUILDING

20' WIDE ROAD TITLE:


G+1 STOREY BUILDING

DESIGN DRAWN CHECKED APPROVED


A.V.R A.V.R B.S.R B.S.R
DATE: 16/06/2021 SCALE: N/A

DRG. No: SITE LAYOUT PLAN

REVISION:

SITE LAYOUT CONSULTANT:


..\Bhavanam's\BHAVANAM'S LOGO\BHAVANAM'S Sandeep R1.png

ARCHITECTS, ENGINEERS & INTERIOR DESIGNERS


Visakhapatnam.
Contact No: +91 9110-363-544.
EMAIL ID: wewillhelpyou007@gmail.com
© BHAVANAM'S C 2 C
THIS DOCUMENT SHOULD NOT BE RELIED ON
OR USED IN CIRCUMSTANCES OTHER THAN
THOSE FOR WHICH IT WAS ORIGINALLY
PREPARED AND FOR WHICH BHAVANAM C2C
WAS COMMISIONED. BHAVANAM C2C ACCEPTS
NO RESPONSIBILITY FOR THIS DOCUMENT TO
ANY OTHER PARTY OTHER THAN THE PERSON
BY WHOM IT WAS COMMISIONED.

DESIGN NOTES:
1. GRADE OF CONCRETE CONFIRMING TO IS
456:2000 IS :
2. THE STRUCTURAL STEEL SHALL BE HIGH
YIELD STRENGTH DEFORMED BAR
CONFIRMING TO IS 1786:2008 IS :
3. S.B.C OF SOIL IS TAKEN AS :
4. STRUCTURE IS DESIGNED FOR:
V

NOTES:
1. ALL DIMENSIONS ARE IN FEET AND INCHES,
UNLESS OTHERWISE MENTIONED.
TOILET 2. DIMENSIONS ARE NOT TO BE SCALED. ONLY
7'0"X4'0" WRITTEN DIMENSIONS ARE TO BE FOLLOWED.
3. THIS DRAWING SHALL BE READ IN
CONJUNCTION WITH RELEVANT
ARCHITECTURAL, STRUCTURAL AND
ELECTRICAL DRAWINGS AND ALL RELEVANT
SECTIONS OF THE SPECIFICATIONS, IF
C.BED ROOM APPLICABLE.
M.BED ROOM W1
9'4"X12'0" 4. ANY DISCREPANCY, ERROR OR AMBIGUITY
SHALL BE IMMEDIATELY REFERRED TO THE
W2 11'0"X12'0" ENGINEER-IN-CHARGE FOR CLARIFICATION.
.

TOILET
V 6'6"X4'0" TOILET V
7'0"X4'0"

G.BED ROOM
11'0"X10'0"

W1
REVISION:

LIVING ROOM
13'8"X18'4" W2

KITCHEN
11'0"X8'0"
POOJA
4'0"X1'6"
RELEASED FOR: DIRECTION:
W2
LANDING

INFORMATION

UP
TENTATIVE
REVIEW
N
CONSTRUCTION
MAIN GATE

CLIENT:

G.S.REDDY

PROJECT:

RESIDENTIAL BUILDING
TITLE:
G+1 STOREY BUILDING
GATE DESIGN DRAWN CHECKED APPROVED
A.V.R A.V.R B.S.R B.S.R
DATE: 16/06/2021 SCALE: N/A

DRG. No: GROUND FLOOR PLAN

REVISION:

GROUND FLOOR CONSULTANT:


..\Bhavanam's\BHAVANAM'S LOGO\BHAVANAM'S Sandeep R1.png

ARCHITECTS, ENGINEERS & INTERIOR DESIGNERS


Visakhapatnam.
Contact No: +91 9110-363-544.
EMAIL ID: wewillhelpyou007@gmail.com
© BHAVANAM'S C 2 C
THIS DOCUMENT SHOULD NOT BE RELIED ON
OR USED IN CIRCUMSTANCES OTHER THAN
THOSE FOR WHICH IT WAS ORIGINALLY
PREPARED AND FOR WHICH BHAVANAM C2C
WAS COMMISIONED. BHAVANAM C2C ACCEPTS
NO RESPONSIBILITY FOR THIS DOCUMENT TO
ANY OTHER PARTY OTHER THAN THE PERSON
BY WHOM IT WAS COMMISIONED.

DESIGN NOTES:
1. GRADE OF CONCRETE CONFIRMING TO IS
456:2000 IS :
2. THE STRUCTURAL STEEL SHALL BE HIGH
YIELD STRENGTH DEFORMED BAR
BALCONY BALCONY CONFIRMING TO IS 1786:2008 IS :
3. S.B.C OF SOIL IS TAKEN AS :
11'2"X3'2" 13'10"X3'2" 4. STRUCTURE IS DESIGNED FOR:
V

NOTES:
1. ALL DIMENSIONS ARE IN FEET AND INCHES,
UNLESS OTHERWISE MENTIONED.
TOILET 2. DIMENSIONS ARE NOT TO BE SCALED. ONLY
7'0"X4'0" WRITTEN DIMENSIONS ARE TO BE FOLLOWED.
3. THIS DRAWING SHALL BE READ IN
CONJUNCTION WITH RELEVANT
ARCHITECTURAL, STRUCTURAL AND
ELECTRICAL DRAWINGS AND ALL RELEVANT
SECTIONS OF THE SPECIFICATIONS, IF
C.BED ROOM APPLICABLE.
M.BED ROOM W1 4. ANY DISCREPANCY, ERROR OR AMBIGUITY
9'4"X12'0" SHALL BE IMMEDIATELY REFERRED TO THE
W2 11'0"X12'0" ENGINEER-IN-CHARGE FOR CLARIFICATION.
.

TOILET
V 6'6"X4'0" TOILET V
7'0"X4'0"

G.BED ROOM
11'0"X10'0"

W1
REVISION:

LIVING ROOM
13'8"X18'4" W2

KITCHEN
11'0"X8'0"
POOJA
4'0"X1'6" DIRECTION:
RELEASED FOR:
W2
INFORMATION
LANDING

UP
5' WIDE CORRIDOR
TENTATIVE
REVIEW
N
CONSTRUCTION

CLIENT:
MAIN GATE

G.S.REDDY

PROJECT:

RESIDENTIAL BUILDING
TITLE:
G+1 STOREY BUILDING
GATE DESIGN DRAWN CHECKED APPROVED
A.V.R A.V.R B.S.R B.S.R
DATE: 16/06/2021 SCALE: N/A

DRG. No: FIRST FLOOR PLAN

REVISION:

FIRST FLOOR CONSULTANT:


..\Bhavanam's\BHAVANAM'S LOGO\BHAVANAM'S Sandeep R1.png

ARCHITECTS, ENGINEERS & INTERIOR DESIGNERS


Visakhapatnam.
Contact No: +91 9110-363-544.
EMAIL ID: wewillhelpyou007@gmail.com

You might also like