You are on page 1of 1

NOTE:

1. ALL DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS


UNLESS OTHER WISE NOTED.
2. DIMENSIONS SHALL NOT BE SCALED FROM THE DRAWING.
ONLY WRITTEN DIMENSIONS SHALL BE FOLLOWED.
D D D D 3. CONCRETE GRADE :M35
4. REINFORCING STEEL SHALL BE THERMO-MECHANICALLY TREATED
REINFORCEMENT BARS OF GRADE 500 D CONFIRMING TO IS:1786
5. CLEAR COVER TO REINFORCEMENT : PIER-50mm & PILE CAP-75mm
6. BENDING OF REINFORCEMENT BARS SHALL BE AS PER IS:2502-1963
7. ANCHORAGE LENGTH, LAP LENGTH, BAR SPACING'S AND OTHER
FOR CRASH BARRIER DETAILS FOR CRASH BARRIER DETAILS REINFORCEMENT REQUIREMENT SHALL COMPLY WITH
REFER SEPARATE DRAWING REFER SEPARATE DRAWING SPECIFICATIONS GIVEN IN IRS-CBC CLAUSE 15.9.6.6.

DIAMETER OF BAR.
9. NOT MORE THAN 50% OF THE BAR SHALL BE LAPPED AT
ANY LOCATION.

BETWEEN ADJACENT BAR.


11. THIS DRAWING SHALL BE READ IN CONJUNCTION WITH ALL
RELEVANT DRAWING.
12. WELDING OF REINFORCEMENT SHALL NOT BE PERMITTED.
13. ALL DIMENSIONS ARE TO BE READ AND NOT MESURED NITHER ON
DRAWINGS NOR ON ELECTRONIC COPY.

REFERENCE DRAWINGS:
MEGA-STUP-ST-NS-APM-PK1-FDN-001 ..... CO-ORDINATES OF COLUMN
& PILE FOR APMC STATION

MEGA-STUP-ST-NS-APM-PK1-FDN-002 ..... DETAILS OF PILE FOUNDATION


FOR COLUMN AT GRID C2 TO C9
OF APMC STATION

MEGA-STUP-ST-NS-APM-PK1-MSC-001 .....TYPICAL DETAILS OF


CRASH BARRIER FOR
RECTANGULAR COLUMN

SECTION A-A MEGA-STUP-ST-NS-APM-PK1-SUB-001 .....REINFORCEMENT DETAILS OF

(SCALE 1:50) SECTION B-B COLUMN C2 TO C9


(SCALE 1:50)

LONGITUDINAL DIRECTION LEGEND:


REINFORCEMENT AT TOP
OF COLUMN / PILE CAP
REINFORCEMENT AT BOTTOM

C B

ISSUE RECORD GOOD FOR CONSTRUCTION


GOOD FOR CONSTRUCTION PRELIMINARY DESIGN
DESIGN DEVELOPMENT TENDER DRAWINGS
REVISION CONTROL
OF COLUMN / PILE CAP
TRANSVERSE DIRECTION

R0 22/02/2016 FOR APPROVAL


REV. DATE DESCRIPTION OF CHANGES /CLOUDING

A A NO OBJECTION FOR CONSTRUCTION

MANAGER (DC)

GM/SYS GM/S&T GM (P&D)

GENERAL ENGINEERING CONSULTANT


CONSORTIUM OF SYSTRA-RITES-OCG-AECOM
THE DESIGN AND DRAWING AS CERTIFIED AND SUBMITTED BY THE DETAILED DESIGNER
CONSULTANT HAVE BEEN PROOF CHECKED BY GENERAL ENGINEERING CONSULTANTS
AND IS RECOMMENDED FOR NO OBJECTION BY MEGA

CSE CTE CTRAE CIE

CDA CSDE CDE (E & M) PD (DY. P.D.)


C CLIENT :
METROLINK EXPRESS GANDHINAGAR AND AHMEDABAD
B DETAILED DESIGN CONSULTANT (DDC) :

STUP Consultants Pvt. Ltd.


REINF. DETAILS OF PILE CAP SECTION C-C REGISTERED OFFICE: 1004-5
RAHEJA CHAMBERS NARIMAN POINT
(SCALE 1:50) (SCALE 1:50) MUMBAI 400 021

PROJECT NAME :
DETAILED DESIGN CONSULTANCY SERVICES FOR VIADUCT
CORRIDOR-NORTH SOUTH (APMC TO MOTERA STATION) ALL ELEVATED
SCHEDULE OF REINFORCEMENT VIADUCT PORTIONS FOR METRO LINK EXPRESS FOR GANDHINAGR AND
LONGITUDINAL DIRECTION AHMEDABAD (MEGA) COMPANY LIMITED
CONTRACT ID : MEGA/DDC/VDT/N-S/1
DRAWING NAME/TITLE :

REINFORCEMENT DETAILS OF PILE CAP


TRANSVERSE DIRECTION

AND COLUMN STARTER


AT LOCATION C2 TO C9 OF APMC STATION
DRAWING NO. : REV.

MEGA-STUP-ST-NS-APM-PK1-FDN-04 R0
DATE : 18/02/2016 SCALE : 1:50 SHEET NO. : -

IT IS CERTIFIED THAT DETAILED DESIGN PREPARED IS COMPLIED WITH THE TERM


& CONDITION OF CONTRACT AND WE OWN FULL RESPONSIBILITY FOR DESIGN,
ADEQUACY & MEETING FUNCTIONAL, PERFORMANCE AND OPERATIONAL
REQUIREMENTS INCLUDING CONSIDERATION FOR INTERFACE REQUIREMENT OF
OTHER CONCERNED DESIGNER/ CONTRACTOR AND COMPLIANCE TO STANDARDS,
NORMS, SAFETY AND STATUTORY RULES & REGULATIONS.

SECTION D-D 20/02/206 20/02/206 20/02/206


(SCALE 1:50)
P.B. KAMATE D.C. ATHAVALE A. SENGUPTA P.K. CHOUDHARY

PREPARED BY CHECKED BY APPROVED BY ISSUED BY


FILE NAME: O:\8108\WORKING\02 STATIONS\01 EDD\01 APMC STATION\MEGA-STUP-ST-NS-APM-PK1-FDN-04 R0.DWG SHEET SIZE: A1 PLOTTING SCALE 1:1