1. DISCREPENCY AMONGST THIS STRUCTURAL DRG. THE CORRES-
PONDING ARCHITECTURAL DRAWINGS AND THE AGREEMENT ITEM IF ANY, SHALL BE GOT RECONCILED BEFORE EXECUTION. 2. ALL DIMENSIONS ARE IN MM UNLESS OTHERWISE SPECIFIED. 3. NO DIMENSION ARE TO BE SCALED OUT FROM DRAWING, ONLY FIGURE WRITTEN DIAMENSIONS SHALL BE FOLLOWED. 4. DIAMENSION ARE TO BE VERIFIED AT SITE BEFORE EXECUTION OF WORK. 5. VARIOUS APPLICABLE PROVISIONS OF I.S. :456-2000 SHALL BE FOLLOWED FOR R.C.C WORK. 6. CEMENT CONCRETE MIX SHALL BE OF DESIGN MIX OF M-25 FOR ALL STRUCTURAL WORK AS PER CPWD SPECIFICATIONS AND RELEVENT I.S. CODE AND AGREEMENT. 7. ALL REINFORCEMENT SHALL BE OF HIGH YIELD STRENGTH THERMO MECHANICALLY TREATED BARS.(Fe-500D) TMT CONFORMING TO IS-1786. 8. REINFORCEMENT SHALL HAVE NOMINAL COVER EXCLUDING PLASTER OR OTHER DECORATIVE FINISH AS FOLLOWS :- a) FOR PILE SHAFT :- 50MM b) FOR COLUMN :- 40MM c) FOR BEAM :- 30MM d) FOR PILE CAP :- 75MM NOMINAL COVER TO REINFORCEMENT SHALL BE THICKNESS OF CONCRETE COVER TO ALL STEEL REINF INCLUDING TYPICAL SECTION OF SLAB SECONDARY REINF ALSO. 9. NOT MORE THAN 50% OF BARS SHALL BE SPLICED AT ONE SECTION IN COLUMNS AND BEAMS. 10. THE TOP OF ALL GRADE BEAMS SHALL BE AT 150MM ABOVE FORMATIONG/FINISHED GROUND LEVEL. 11. IF ANY ACTUAL SUB SOIL CONDITION DURING EXCAVATION DIFFER FROM AS REPORTED OR LOOSE STRATA FOUND THE SAME MAY BE REPORTED TO THIS OFFICE BEFORE EXECUTION. 12. LOAD CARRYING CAPACITY OF PILE HAS BEEN ADOPTED AS 510 KN FOR 500 MM DIA PILE AS PER SOIL TEST REPORT. A) PILE SHOULD PROJECT 50MM MIN. INTO THE PILE CAP. B) LENGTH OF PILE IS 25.00M BELOW BOTTOM LEVEL OF PILE CAP. 13. NOT MORE THAN ONE THIRD OF TOTAL NOS OF MAIN BARS SHALL BE OVER LAPPED AT ANY SECTION OF COLUMN. d d 14. DEVELOPMENT LENGTH OF REINFORCEMENT BARS SHALL BE IN TENSION-- 49X DIA. OF BAR. IN COMPRESION -- 39X DIA. OF BAR LAP LENGTH--- 49 X DIA. OF BAR. 15. LAP SHALL BE STAGGERED AND AVOIDED AT THE POINTS OF MAXIMUM BENDING. 16. ALL BRICK WALLS SHALL BE RAISED AFTER THE SHUTTERING OF HOOP SPACING d/4 OR 8 d b BEAM AND SLAB BELOW ARE REMOVED. WHICHEVER IS LESS 17. LAP SPLICE SHALL BE IN CENTRAL HALF OF COLUMN LENGTH AND SHALL PROPORTIONED AS TENSION SPLICE. CLEAR SPAN (L) d b = DIAMETER OF LONGITUDINAL BAR 18. TIES/STIRRUS SPACING IN ENTIRE SPLICE LENGTH IN COLUMN SHALL NOT EXCEED 100 C/C. 19. MINIMUM LENGTH OF THE BARS USED IN THE SLAB AS REINFORCEMENT SHALL BE 2Ld, WHERE 'Ld' IS THE DEVE- -LOPMENT LENGTH OF THE BAR. 20. LAP SHALL NOT BE PROVIDED IN A BEAM WITHIN A DISTANCE OF 2d FROM JOINT FACE. 21. BOTTOM MOST LAYER OF REINFORCEMENT IN FOOTING SHALL BE PLACED ALONG THE SIDE WHICH ONE IS HAVING LARGER OUTSTAND BEYOND THE COLUMN/ PEDESTAL FACE. 22. IN COLUMN REINFORCEMENT, LARGER DIAMETER REINFORCEMENT BAR SHALL BE PLACED AT CORNER WHENEVER TWO DIFFERENT DIA OF BAR ARE USED. 24. DETAILING OF REINFORCEMENT SHALL BE AS PER SP-34, IS-456-2000 & IS-13920-2016. 10$ @ 150 C/C BOTH WAYS 75 115 2NOS-12$ MAX 600 150 2L-8$ @ 90 C/C O/o THE CHIEF ENGINEER TYP. REINFORCEMENT DET. OF 600 WIDE CPWD, AGARTALA. 2NOS-12$ RCC SHELF IN KITCHEN CHECKED BY :- RE-CHECKED BY :- APPROVED BY :- 230 2NOS-12$ 2L-8$ @ 90 C/C A.E.E./CPWD E.E./CPWD CE/CPWD/AGARTALA. 150 PROJECT :- C/o 'A' TYPE SCHOOL BUILDING FOR 3NOS-12$ 60° KV AT LAMPHELPATE, IMPHAL JOB :- STRUCTURAL DRAWING. (BEAM BARS & STIRRUPS NOT TITLE :- GENERAL NOTES & TYPICAL (STIRRUP NOT SHOWN) SHOWN FOR CLARITY) DETAILS. DRG.NO. :- CE/AGT/KV/LAMPHAL/G+2/ 00 (A) PREPARED BY. :- CIVIL ENGINEERING DEPARTMENT GUWAHATI