You are on page 1of 1

GENERAL NOTES:

1. ALL SANITARY WORKS INCLUDED HEREIN SHALL BE EXECUTED ACCORDING TO THE PROVISIONS OF THE NATIONAL
BUILDING CODE OF THE PHILIPPINES, THE NATIONAL PLUMBING CODE OF THE PHILIPPINES AND ITS IMPLEMENTING
RULES AND REGULATIONS.

S IT E 2. COORDINATE THE DRAWING WITH OTHER RELATED DRAWINGS AND SPECIFICATION THE ARCHITECT OR ENGINEER
SHALL BE NOTIFIED IMMEDIATELY OF ANY DISCREPANCY FOUND THEREIN.

3. ALL PIPES SHALL BE INSTALLED AS INDICATED, ANY RELOCATION REQUIRED FOR PROPER EXECUTION OF OTHER
TRADES SHALL BE WITH PRIOR APPROVAL OF THE ARCHITECT.

4. PROPOSED SANITARY UTILITIES SHALL CONFORM TO THE ACTUAL LOCATION, DEPTH AND INVERT ELEVATION OF
EXISTING PIPES AND STRUCTURES AS VERIFIED BY THE CONTRACTOR.

5. THE CONTRACTOR SHALL VERIFY ALL EXISTING UTILITIES AT THE SITE AND COORDINATE THE WORKS WITH THE
SEWER DISPOSAL POINTS AND WATERLINE CONNECTING POINTS.

6. ALL SLOPES FOR THE HORIZONTAL DRAINAGE SHALL MAINTAIN ONE PERCENT AS MINIMUM UNLESS OTHERWISE
SPECIFIED.

7. SIZE OF WATER SUPPLY PIPES TO FIXTURES SHALL BE IN ACCORDANCE WITH THE MANUFACTURE'S INSTRUCTIONS.

8. ALL DOWN SPOUT SHALL BE P.V.C. POLYVINYL CHLORIDE UNLESS OTHERWISE SPECIFIED BY THE ARCHITECT AND

VICINITY MAP ENGINEER.

SCALE NTS 9. ALL SIZES ARE IN MILLIMETER AND ALL DIMENSION IN METERS UNLESS OTHERWISE SPECIFIED.

10. ALL WORKS TO BE DONE SHALL BE WITH DIRECT SUPERVISION OF A REGISTERED SANITARY ENGINEER OR MASTER
PLAUMBER.
PROPERTY LINE
ROOFING

LEGEND:
SEWER LINE L. LAVATORY SINK
STORM DRAINAGE W.C. WATER CLOSET
STORM DRAINAGE MH. MANHOLE
G.V. GATE VALVE C.B. CATCH BASIN
MAIN GATE W.M. WATER METER R.D. ROOF DRAIN
C.V. CHECK VALVE VSTR. VENT STACK THRU ROOF
F FAUCET S. SINK
S.T. SEPTIC TANK D.S. DOWN SPOUT
SETBACK
500

SITE DEVELOPMENT PLAN


SCALE 1:100 MTRS.

PREPARED BY: LICENSES: PROJECT TITLE AND LOCATION: CHECKED : RECOMMENDING APPROVAL : APPROVED : SHEET CONTENTS: S H E E T NO.:

PRC REG. NO. 0001491


PTR NO. 0700933
EDGECOMM INCORPORATED
GENERAL NOTES
VICINITY MAP
P-1
SITE DEVELOPMENT PLAN
ERMELO R. PONDEVIDA
DATE ISSUED
PLACE ISSUED
FEB. 25, 2023
QUEZON CITY
LEGEND 3
JAN. 11, 2021
SANITARY ENGINEER T.I.N. LOCATION : 33 RUSIA ST., PARAÑAQUE METRO MANILA CAD BY: