Content
1. Warnings··
·········
···········
···········
···········
···········
··········2
3. Wiring diagram········
·········
···········
···········
···········
·········4
1
AUTOMATIZACIÓN DE SISTEMAS Y PROCESOS INDUSTRIALES ASM S.A. DE C.V
RFC.: ASP100409TR2
asmx
DE LAS DUNAS #44 COL. RESIDENCIAL ACUEDUCTO C.P. 07279 MÉXICO D.F.
Tel: (55)5367-5105; (55)6363-8971
EMAIL: info@asmx.com.mx
MR
www.asmx.com.mx
Wiring
C1 B1 A1 C2 B2 A2 C3 B3 A3 ① ② ③ ④ ⑤ ⑥ ⑦ ⑧ ⑨ ⑩ ⑪ ⑫
Pluse
Pluse Bsignal
Relayー1output Relayー2output Relayー3output +12V COM2
A
Control loop terminal (abnormal) (open arrival) (close arrival)
signalarrival signal
Open
Close arrival
Safe inductor
Open shift signal
Close shift signal
COM1
‘Open’comand
‘Close’ comand
signal
signal
signal
ENCODER
+
RS485
-
+
RS485
-
Communicate Short connect the last terminals
terminal (never connect)
2
AUTOMATIZACIÓN DE SISTEMAS Y PROCESOS INDUSTRIALES ASM S.A. DE C.V
RFC.: ASP100409TR2
asmx
DE LAS DUNAS #44 COL. RESIDENCIAL ACUEDUCTO C.P. 07279 MÉXICO D.F.
Tel: (55)5367-5105; (55)6363-8971
EMAIL: info@asmx.com.mx
MR
www.asmx.com.mx
(2) After checking, set the controller under the inspection signal N16, make the
elevator door have a full “open and close” run by hand to observe the
inspection signal during the process. When the “door open”, open to the
position 3, indicator of open deceleration 6 on. When the “door closed”, close
to position 4, indicator of close deceleration 7 on.. If the display status of
inspection signal is error, change wiring terminal or replace the magnistor
position.
Ensure the logic of input signal is correct, otherwise, the following procedure could
not be done.
Inspection signal N16 as the figure below:
6 5 4 3 2 1
9 8 7
Output signal
C1 B1 A1 C2 B2 A2 C3 B3 A3
3
AUTOMATIZACIÓN DE SISTEMAS Y PROCESOS INDUSTRIALES ASM S.A. DE C.V
RFC.: ASP100409TR2
asmx
DE LAS DUNAS #44 COL. RESIDENCIAL ACUEDUCTO C.P. 07279 MÉXICO D.F.
Tel: (55)5367-5105; (55)6363-8971
EMAIL: info@asmx.com.mx
MR
www.asmx.com.mx
All the four switches are normal open, consider as positive logic. Make the elevator
door have a full “open and close” run by hand. If magic steel pass switch 6 or arrival
at switch 3 during opening, the switch is close; If magic steel pass switch 7 or arrival
at switch 4 during closing, the switch is close. Otherwise it is negative logic.
7 4 6 3
door deceleration door closed door deceleration door open
on closing on opening
4
AUTOMATIZACIÓN DE SISTEMAS Y PROCESOS INDUSTRIALES ASM S.A. DE C.V
RFC.: ASP100409TR2
asmx
DE LAS DUNAS #44 COL. RESIDENCIAL ACUEDUCTO C.P. 07279 MÉXICO D.F.
Tel: (55)5367-5105; (55)6363-8971
EMAIL: info@asmx.com.mx
MR
www.asmx.com.mx
Debugging
Note: each parameter has been initial set EX-work. Basically you don’t need to set the
parameter any more. But if you need to adjust the running curve or set the parameters,
you may refer to the following parameter type and recommended parameter values.
Para Refere
Para Range of
meter nce description Note
meter setting
type value
0,1 panel operate;
U01 p08 2.0 Chose running command 0~3
2 outside control
0 panel operate; 4 door
control in SW
U02 p09 4.0 Frequency set signal 0~6 mode(normal); 5 door
control in SW
mode(repeat);
It should not be too higher.
Otherwise, lead to
U03 p05 13 Torque upgrade (%) 0~40
excessive electrical
current, heat overload.
Opening period. Pre-speed
U04 d20 6.0 Open frequency 6 ( Hz) 0.05~250
period of door open
Door open holding
U05 d43 3.0 0.5~250
stand-by frequency ( Hz)
Closing period. Pre-speed
U06 d27 6.0 Close frequency 6 ( Hz) 0.05~250
period of door close.
Adjust the degree of cam
retraction, when closing. It
Door closed holding should not be too higher.
U07 d14 2.0 0.05~250
frequency ( Hz) Otherwise, lead to
excessive electrical
current, heat overload.
Door closed holding
U08 d44 2.0 0.5~250
stand-by frequency ( Hz)
Open accelerating and Opening period. Time
U09 d33 1.0 0.1~999
decelerating time 6 (S) value of decelerating.
Close accelerating and Closing period. Time
U10 d39 1.2 0.1~999
decelerating time 6 (S) value of decelerating.
5
AUTOMATIZACIÓN DE SISTEMAS Y PROCESOS INDUSTRIALES ASM S.A. DE C.V
RFC.: ASP100409TR2
asmx
DE LAS DUNAS #44 COL. RESIDENCIAL ACUEDUCTO C.P. 07279 MÉXICO D.F.
Tel: (55)5367-5105; (55)6363-8971
EMAIL: info@asmx.com.mx
MR
www.asmx.com.mx
data change
u01 p05 12
Comfirm
MODE SET distributive
SET SET u02 MODE 000
function at NO.: display
present.region next
u10 shows the point 13 user-defined
behind (p,d). Variable data parameter NO.
2) Avoiding to set too much parameters, we advice you to adjust the parameters
in the table. If the door running curve is normal, you needn’t set other
parameters. So we lock the function area d,p. If you need to adjust the
parameter in function area d,p, remember the password is 001 and follow the
step below:
MODE SET
p06
MODE SET
d21
3) Adjust the curve after entering p,d area: please set p08=1, and set p09=5.
P63=0 P67=0
Please adjust the curve by SW mode and refer to the step (5). Before elevator
door controller control the door running, please set p08 to 2 and set p09 to 4.
6
AUTOMATIZACIÓN DE SISTEMAS Y PROCESOS INDUSTRIALES ASM S.A. DE C.V
RFC.: ASP100409TR2
asmx
DE LAS DUNAS #44 COL. RESIDENCIAL ACUEDUCTO C.P. 07279 MÉXICO D.F.
Tel: (55)5367-5105; (55)6363-8971
EMAIL: info@asmx.com.mx
MR
www.asmx.com.mx
Setting value
A contact input="0": When SW(switch) signal is closed (terminal level is "L"),
NO is detected.
B contact input="1": When SW(switch) signal is opened (terminal level is "H"),
NO is detected.
Setting method
Convert 0 to 4 bits to decimal numbers and input.
Input the total value of the setting value×the additional value for the setting
data.
(Example) When CLOSE speed change signal (4bits) and OPEN speed change
signal (3bits) is B contact input.
Setting data=(1×16)+(1×8)+(0×4)+(0×2)+(0×1)=24
4bit 3bit 2bit 1bit 0bit=24
Note: The logics of the OPEN signal and CLOSE signal cannot be changed. "A
contact input" is a fixed value.
7
AUTOMATIZACIÓN DE SISTEMAS Y PROCESOS INDUSTRIALES ASM S.A. DE C.V
RFC.: ASP100409TR2
asmx
DE LAS DUNAS #44 COL. RESIDENCIAL ACUEDUCTO C.P. 07279 MÉXICO D.F.
Tel: (55)5367-5105; (55)6363-8971
EMAIL: info@asmx.com.mx
MR
www.asmx.com.mx
d17
d19 Open hold
Hold
current
d32 wait
d29 timer d40
Frequency
d30 d33 d45 Holding operation
Curve
d28 d16 d20
d15 d43
d47 d48 P02 d21
DOOR Area 0 1 2 3 5 6 7
OPEN signal
ON
CLOSE signal
ON
OPEN arrival
Signal ON
Open speed
change signal ON
Close speed
change signal ON Note: The speed change does not occur
with the CLOSE speed change signal
CLOSE arrival
signal ON
Start timer
d47
Deceleration timer
d48
Deceleration timer
d50
8
AUTOMATIZACIÓN DE SISTEMAS Y PROCESOS INDUSTRIALES ASM S.A. DE C.V
RFC.: ASP100409TR2
asmx
DE LAS DUNAS #44 COL. RESIDENCIAL ACUEDUCTO C.P. 07279 MÉXICO D.F.
Tel: (55)5367-5105; (55)6363-8971
EMAIL: info@asmx.com.mx
MR
www.asmx.com.mx
9
AUTOMATIZACIÓN DE SISTEMAS Y PROCESOS INDUSTRIALES ASM S.A. DE C.V
RFC.: ASP100409TR2
asmx
DE LAS DUNAS #44 COL. RESIDENCIAL ACUEDUCTO C.P. 07279 MÉXICO D.F.
Tel: (55)5367-5105; (55)6363-8971
EMAIL: info@asmx.com.mx
MR
www.asmx.com.mx
Note:
1、 The change of all the parameters is relevant, if you increase or decrease even much, the
negative problem will appear.
2、 All the electric debugging is based on the mechanism that installation is good.
10