You are on page 1of 4

Installation and Setup Instructions

FAS80xx Systems with I/O Expansion Modules

1 Prepare for installation (Choose option A or B below) 1 2 3 4 5

A For Clustered Data ONTAP B For 7-Mode, HA

Storage / HA cable Storage / HA cable


In the box: Power cables In the box: Power cables
Starter network cable Starter network cable

Configuration
Serial cable Serial cable
10 GbE cable worksheet not needed for 10 GbE cable
this configuration

You provide: You provide:

Microsoft Windows client Additional network cables


Rack space - 6U For connecting your storage to your network
Runs the software to configure
Rack space - 6U switch and Microsoft® Windows® client
your storage system

Serial console connection


Connection to DB9 serial console port
Additional network cables or USB-to-DB9 converter to laptop
For connecting your storage to your network
switch and Microsoft® Windows® client Screwdriver Screwdriver

• System Setup Software • System configuration worksheet


http://support.netapp.com/NOW/public/system_setup/ http://support.netapp.com/documentation/
• OnCommand System Manager productlibrary/index.html?productID=30092
Download: http://support.netapp.com/NOW/cgi-bin/software/ Download: • OnCommand System Manager
http://support.netapp.com/NOW/cgi-bin/software/
• Config Advisor
http://support.netapp.com/NOW/download/tools/config_advisor/ • Config Advisor
http://support.netapp.com/NOW/download/tools/config_advisor/

210-06544+A0
2 Install hardware
1 3
1 2 3 4 5

2 4

BACK VIEW OF SYSTEM FRONT VIEW OF SYSTEM


1 3
Gigabit Ethernet
PCIe expansion slots NVRAM ports (e0i-e0l)
2 LED 4
LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK NV

0a 0b 0c 0d 1
e0a e0b e0c e0d
1 e0e 0e e0f 0f e0g 0g e0h 0h 3
3 e0i e0j e0k e0l

2 4
2 4

LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK NV

Console port
0a 0b 0c 0d e0a e0b e0c e0d e0e 0e e0f 0f e0g 0g e0h 0h e0i e0j e0k e0l (Setting:
9600 N-8-1)
LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK NV

0a 0b 0c 0d e0a e0b e0c e0d e0e 0e e0f 0f e0g 0g e0h 0h e0i e0j e0k e0l

LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK NV

0a 0b 0c 0d e0a
1 e0b e0c e0d e0e 0e
5
e0f 0f e0g 0g e0h 0h
3e0i 9
e0j e0k e0l
A B

SAS ports 6 10
ACP port
(0a-0d) 2 4 (locked wrench icon)
7 11

8 12
Remote/Node A B
Management port
LNK LNK (wrench icon) Power LED
ib0a HA ib0b
A B Controller A and B
Bezel
LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK NV
activity LEDs
HA ports Attention LED
I/O expansion (ib0a-ib0b)
0a 0b 0c 0d e0a e0b e0c e0d e0e 0e e0f 0f e0g 0g e0h 0h e0i e0j e0k e0l
module
10 Gigabit Ethernet attention LED
PCIe expansion
ports (e0a-e0d) slots
10 Gigabit Etnernet ports (e0e-e0h) or
Fibre Channel ports (0e-0h) (SFP dependent)

OPTIONAL 2-POST Handles and


1 Install system MID-MOUNT BRACKETS cable management device

• Rack the system. CAUTIO N LIFTING HAZARD

Rail kit: Follow instructions in the rail kit.


OR System cabinet: install in the system cabinet. 115 lbs. (52.2 kg)
No PCIe cards in System

• Place the bezel on the front of the system.

2 Cable controller to switches and power (Choose option A or B below)


See your network administrator for help connecting to your switch.

1 Attach cable management tray.


(Not shown)
A Clustered Data ONTAP, two node switchless cluster
4 TO MANAGEMENT NETWORK SWITCH
2 HA cables

Connect HA ports ib0a to ib0a


1 3 1 3

2 4
3 2 4

and ib0b to ib0b.


LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK NV LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK NV

3 10GbE Network cables


0a 0b 0c 0d e0a e0b e0c e0d e0e 0e e0f 0f e0g 0g e0h 0h e0i e0j e0k e0l 0a 0b 0c 0d e0a e0b e0c e0d e0e 0e e0f 0f e0g 0g e0h 0h e0i e0j e0k e0l

5 9 5 9

OPTION A: Connect the cluster 8


6 10 6 10

interconnect e0a to e0a, e0c to 7

8
11

12
7

8
11

12

e0c. Optional - e0b to e0b, and LNK

ib0a HA ib0b
LNK LNK

ib0a HA ib0b
LNK

e0d to e0d ports on both con- 2

trollers.
5 TO GbE DATA NETWORK SWITCHES
OPTION B: Connect e0a and 6 TO DATA NETWORK SWITCHES
e0d to switches. Optional - con-
nect e0b and e0d to switches.
4 Network cables B 7-Mode and clustered Data ONTAP, Switched HA configuration
Connect wrench ports to the 4 TO MANAGEMENT NETWORK SWITCH

management switch. 1 3 1 3

2 4 2 4

5 Network cables

Connect GbE ports e0i and e0k LNK

0a
LNK

0b
LNK

0c
LNK

0d
LNK

e0a
LNK

e0b
LNK

e0c
LNK

e0d
LNK

e0e 0e
LNK

e0f 0f
LNK LNK

e0g 0g e0h 0h
NV

e0i e0j e0k e0l


LNK

0a
LNK

0b
LNK

0c
LNK

0d
LNK

e0a
LNK

e0b
LNK

e0c
LNK

e0d
LNK

e0e 0e
LNK

e0f 0f
LNK LNK

e0g 0g e0h 0h
NV

e0i e0j e0k e0l

to GbE data network switches. 5 9 5 9


8
6 10 6 10

6 10GbE Network cables 7 11 7 11

Connect ports e0e|0e and


8 12 8 12

LNK LNK LNK LNK

e0g|0g to data switch.


ib0a HA ib0b ib0a HA ib0b

7 Strap the cables to the cable 5 TO GbE DATA NETWORK SWITCHES


management tray. (Not shown)
SWITCH 6 TO DATA NETWORK SWITCHES
7-Mode data switch 3
8 Power cables
or
Cable both power supplies Cluster interconnect switches

for each chassis.


ALL power cords MUST DO NOT power on system at this point.
be used for all units.
3 Cable storage (Choose option A or B below) 1 2 3 4 5

A HA configuration with DS424x disk shelves


1 2 3
Storage cables 1 3 1 3

2 4 2 4

1 Daisy chain SAS ports.


2 Connect first SAS ports.
LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK NV LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK NV

0a 0b 0c 0d e0a e0b e0c e0d e0e 0e e0f 0f e0g 0g e0h 0h e0i e0j e0k e0l 0a 0b 0c 0d e0a e0b e0c e0d e0e 0e e0f 0f e0g 0g e0h 0h e0i e0j e0k e0l

3 Connect last SAS ports. 5 9 5 9

6 10 6 10

7 11 7 11

4 Network cables 8 12 8 12

Connect ACP ports LNK

ib0a HA ib0b
LNK LNK

ib0a HA ib0b
LNK

on controllers to
the disk shelves and N
IOM6
N
IOM6

LINK

LINK

LINK

LINK
1 2 1 2
3 4 3 4
Disconnect all Disconnect all
supply power for supply power for

shelf-to-shelf ACP ports.


complete isolation. complete isolation.

IOM6 IOM6

complete isolation. complete isolation.


supply power for supply power for
Disconnect all Disconnect all
4 3 4 3
2 1 2 1

N N

N N
IOM6 IOM6

LINK

LINK

LINK

LINK
1 2 1 2
3 4 3 4
Disconnect all Disconnect all
supply power for supply power for
complete isolation. complete isolation.
IOM6 IOM6

complete isolation. complete isolation.


supply power for supply power for
Disconnect all Disconnect all
4 3 4 3
2 1 2 1

N N

N N
IOM6 IOM6
LINK

LINK

LINK

LINK
1 2 1 2
3 4 3 4
Disconnect all Disconnect all
supply power for supply power for
complete isolation. complete isolation.

IOM6 IOM6

complete isolation. complete isolation.


supply power for supply power for
Disconnect all Disconnect all
4 3 4 3
2 1 2 1

N N

N N
IOM6 IOM6
LINK

LINK

LINK

LINK
1 2 1 2
3 4 3 4
Disconnect all Disconnect all
supply power for supply power for
complete isolation. complete isolation.
IOM6 IOM6

complete isolation. complete isolation.


supply power for supply power for
Disconnect all Disconnect all
4 3 4 3
2 1 2 1

N N

N N
IOM6 IOM6
LINK

LINK

LINK

LINK
1 2 1 2
3 4 3 4
Disconnect all Disconnect all
supply power for supply power for
complete isolation. complete isolation.

IOM6 IOM6

complete isolation. complete isolation.


supply power for supply power for
Disconnect all Disconnect all
4 3 4 3
2 1 2 1

N N

N N
IOM6 IOM6
LINK

LINK

LINK

LINK
1 2 1 2
3 4 3 4
Disconnect all Disconnect all
supply power for supply power for
complete isolation. complete isolation.
IOM6 IOM6

complete isolation. complete isolation.


supply power for supply power for
Disconnect all Disconnect all
4 3 4 3
2 1 2 1

N N

B HA configuration with DS2246 disk shelves

1 2 3
1 3 1 3
Storage cables
2 4 2 4

1 Daisy chain SAS ports.


2
LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK

Cable first SAS ports.


NV NV

0a 0b 0c 0d e0a e0b e0c e0d e0e 0e e0f 0f e0g 0g e0h 0h e0i e0j e0k e0l 0a 0b 0c 0d e0a e0b e0c e0d e0e 0e e0f 0f e0g 0g e0h 0h e0i e0j e0k e0l

3 Cable last SAS ports.


5 9 5 9

6 10 6 10

7 11 7 11

4 Network cables 8 12 8 12

Cable ACP ports


LNK LNK LNK LNK

ib0a HA ib0b ib0a HA ib0b

on controllers to
the disk shelves and IOM6 IOM6 IOM6 IOM6
LINK

LINK

LINK

LINK

LINK

LINK

LINK

LINK

IOM6 IOM6 IOM6 IOM6

shelf-to-shelf ACP ports. AC


1
AC AC
1
AC

2 2

IOM6 IOM6 IOM6 IOM6


LINK

LINK

LINK

LINK

LINK

LINK

LINK

LINK

IOM6 IOM6 IOM6 IOM6

AC AC AC AC
1 1

2 2

IOM6 IOM6 IOM6 IOM6


LINK

LINK

LINK

LINK

LINK

LINK

LINK

LINK

IOM6 IOM6 IOM6 IOM6

AC AC AC AC
1 1

2 2

For additional configurations, see HELPFUL LINKS.


4 Complete System Setup (Choose option A or B below) 1 2 3 4 5

A For Clustered Data ONTAP B For 7-Mode, HA


1 Complete configuration worksheet 1 Complete configuration worksheet
From http://support.netapp.com/NOW/ From http://support.netapp.com/documentation/
public/system_setup/ productlibrary/index.html?productID=30092
and select your version of the Data ONTAP Software
Setup Guide for your system
2 Cable Windows client to same
network as your controllers FAS80xx
SYSTEM
2 Cable serial console
WINDOWS CLIENT 1

2
3

Serial cable
VLAN
LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK NV

0a 0b 0c 0d e0a e0b e0c e0d e0e 0e e0f 0f e0g 0g e0h 0h e0i e0j e0k e0l

1 3

2 4

1 3 5 7 9 11 13 15
1 3
LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK NV

1 3 5 7 9 11 13 15
1000/100/10M
LNK / 0a 0b 0c 0d e0a e0b e0c e0d e0e 0e e0f 0f e0g 0g e0h 0h e0i e0j e0k e0l

2 4
2 4 6 8 10 12 14 16
1000/100/10M
LNK /
2 4 6 8 10 12 14 16

MANAGEMENT SUBNET

LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK NV

0a 0b 0c 0d e0a e0b e0c e0d e0e 0e e0f 0f e0g 0g e0h 0h e0i e0j e0k e0l

3 Power on all disk shelves ONLY 1 3

and check IDs 2


LNK
4
LNK
IOM6
A LNK LNK
IOM6

B IOM6

4 Install and run System Setup software 3 Power on all disk shelves,
LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK LNK NV

DC AC DC AC
IOM6
0a 0b 0c 0d e0a e0b e0c e0d e0e 0e e0f 0f e0g 0g e0h 0h e0i e0j e0k e0l
1

*If you cannot use System Setup, see the Data ONTAP Software Setup Guide. x2
2
check IDs, and then 2 x2
2

• Install System Setup software. power on the controllers.


• Do not power on your system until directed ALL power supplies MUST be powered on.

by System Setup software.


Both power supplies MUST be powered on.

• the system. 4 Complete initial


Wait for discover to complete. network configuration
• Enter the values from the configuration worksheet Enter the values from the configuration
into System Setup.* workbook worksheets when prompted by setup script.

5 Complete configuration 1 2 3 4 5

1 Register at support.netapp.com
• Create an account and register your system.
• Get your license keys.

2 Download and run Config Advisor


From http://support.netapp.com/NOW/download/tools/config_advisor/

3 Download OnCommand System Manager


From http://support.netapp.com/NOW/cgi-bin/software/
• Provision more storage.
• Configure other protocols, data protection, and AutoSupport.
• Set up Service Processor and Remote Support Agent.

HELPFUL LINKS
Visit the NetApp web site for more information.
• System Setup information: http://support.netapp.com/NOW/public/system_setup/
support site

• Data ONTAP 8 library: http://support.netapp.com/documentation/productlibrary/index.html?productID=30092


NetApp

• Licenses: http://support.netapp.com/eservice/agree.do?moduleName=PROTOCOL
• Controller and configuration examples; Universal SAS and ACP Cabling Guide: https://library.netapp.com/ecm/ecm_download_file/ECMM1280392
• OnCommand System Manager documentation set: http://support.netapp.com/documentation/productlibrary/index.html?productID=61372
• Data ONTAP Express Guides for your version of Data ONTAP: http://support.netapp.com/documentation/productlibrary/index.html?productID=30092

You might also like