Communications Manual

Printer Communications Manual

Model T7
Revision 2.0.0
Software Version E 9.9.2.21
Hardware Version T-M-6.0.0

Version 2.0.0 Page 1


Communications Manual

TROY T-SERIES INK JET PRINTER

Communications Manual

CONTENTS

CHAPTER 1 RS232 - PCB Settings 2

CHAPTER 2 RS232 - Connection 2

CHAPTER 3 RS232 – Printer Settings 3

CHAPTER 4 Command Summary 4

CHAPTER 5 Message command description 6

Version 2.0.0 Page 2


Communications Manual

CHAPTER 1 RS232 - PCB Settings

DSW2 Serial Mode Set


No. Mode Set-up
1 RS232

2 RS485

3 LAN

CHAPTER 2 RS232 - Connection

CN11 - RS232 Connection PC


Pin1 - Transmit → Pin2 - Receive
Pin2 - Receive → Pin3 - Transmit
Pin3 - Ground → Pin5 - Round

Version 2.0.0 Page 3


Communications Manual

CHAPTER 3 RS232 – Printer Settings

Setting communication environment

Step: Main (M) > System (M3) > Device (M3-5) > RS232

BoudRate DataBit StopBit ParityBit Flow


115200 8 1 NONE HARDWARE
① Close : Close the Window

Setting communication ID

Step: Main (M) > System (M3) > Setting

Change the administrator setting code. ( Administrator’s password: 1111 )

Communication ID : setting ID number to be used for communication ( default value : 0 )

Version 2.0.0 Page 4


Communications Manual

CHAPTER 4 Command Summary

COMMAND EXAMPLES NAME OPTION DETAIL

Examples ID = communication ID in setting menu

ECHO ID,ECHO<CRLF> echo None Check communication


JTST ID,JTST<CRLF> Jet Start None Start
JTSP ID,JTSP<CRLF> Jet Stop None Stop
FSSP ID,FSSP<CRLF> Flush Stop None Flush stop
ATPT ID,ATPT,0,<CRLF> Auto Print 0/1 On or Off for auto print
ATTE ID,ATTE,1,<CRLF> Auto Print Time 1~100 Setting space in auto print
DLON ID,DLON,1,<CRLF> Delay On 0/1 Delay On
DLVE ID,DLVE,1,<CRLF> Delay Value 0~100 Delay Value
SPON ID,SPON,1,<CRLF> Speed On 0/1 Speed On
SPVE ID,SPVE,1,<CRLF> Speed Value 0~100 Speed Value
DRON ID,DRON,1,<CRLF> Direction On 0/1 Direction On
DRVE ID,DRVE,1,<CRLF> Direction Value 0~3 Direction Value
MSLT ID,MSLT<CRLF> Message List None Message List
MSST ID,MSST,1,<CRLF> Message Select Number Message Select
NMMD ID,NMMD,1,abc^2,def<CRLF> Message Modify Field No Current printing msg modify
message
NMIF ID,NMIF,<CRLF> Message info None Current msg info
SMFI ID,SMFI,3,<CRLF> Selected msg info Msg No. Selected msg info
SMFM ID,SMFM,………<CRLF> Selected msg Modify Selected msg Modify
SMFD ID,SMFD,1,<CRLF> Selected msg field Field no Selected msg field delete
del
NMWT ID,NMWT,abc,<CRLF> New msg write Msg name New msg write
NFWT ID,NFWT,<CRLF> New Field write New Field write
GRLT ID,GRLT,<CRLF> Graphic list None Receiving graphic list
MSDT ID,MSDT,1,<CRLF> Message Delete Number Msg delete
DATE ID,DATE,2000,01,01,<CRLF> Date Y,M,D Setting current date
TIME ID,TIME,24,50,50,<CRLF> Time H,M,S Setting current time
ENCD ID,ENCD,1,1,1,<CRLF> Encoder 0/1,0~100,1 Setting encoder
HIVT ID,HIVT,0,<CRLF> High Voltage Set 0~15 Setting high voltage
HIVS ID,HIVS,10,<CRLF> High Voltage 0~15 Setting sensitivity of high
Sensitivity voltage
GUTS ID,GUTS,3800,<CRLF> Gutter Sensitivity 0~4000 Gutter sensitivity
GTOS ID,GTOS,100,<CRLF> Gutter Off set 0~500 Gutter off set
CHRG ID,CHRG,80,<CRLF> Charge 0~200 Charge

Version 2.0.0 Page 5


Communications Manual

PATT ID,PATT,80,<CRLF> Phage Detect Patten 0~200 Phase detector pattern


setting
DUMY ID,DUMY,6,<CRLF> Dummy 0~15 Product value
VISV ID,VISV,50,<CRLF> Viscometer Set 0~200 Viscometer setting
FREQ ID,FREQ,0,<CRLF> Frequency Set 0~15 Frequency setting
MODL ID,MODL,0,<CRLF> Modulation Set 0~500 Modulation setting
RPTP ID,RPTP,1,10,<CRLF> Repeat Print 0/1,0~100 Repeat print setting
BCDO ID,BCDO,1,<CRLF> BCD On 0/1 BCD on
PHOT ID,PHOT,0,1,0,<CRLF> Photo Sense Set 1/2,0/1,0~4 Photo sensor setting
SAVE ID,SAVE<CRLF> Save Information None Save Setting, log, SD card
SLED ID,SLED,1,<CRLF> strobe led 0/1 Strobe LED ON/OFF
PSGL ID,PSGL,<CRLF> Print Signal None Print signal
BCLN ID,BCLN,<CRLF> Back Clean None Start back cleaning
LRRD ID,LRRD,<CRLF> Direction Change None Left/right direction change
CYCO ID,CYCO,<CRLF> Cycle 0/1 Basic cycle operation
PEEC ID,PEEC,1,<CRLF> Setting echo 0/1 Result after communication
PAUS ID,PAUS,0<CRLF> Pause set 0/1 Pause setting
MST1 ID,MST1<CRLF> Printer status None Receive Printer status
MST2 ID,MST2<CRLF> Printer status None Receive Printer status
NMCC ID,NMCC,1<CRLF> Counter 0~1000000 Initial counter value setting
NMCS ID,NMCS,10,30<CRLF> Counter 0~1000000, Counter initial value, end
0~1000000 value
NMCV ID,NMCV<CRLF> Return Counter Value None Check counter value
CTRS ID,CTRS<CRLF> Counter Reset None Counter Reset
SMCM ID,SMCM<CRLF> Modify Selection None Modify selected message
Message Counter counter
RTTC ID,RTTC<CRLF> Total Counter Return None Return the total counter
NERS ID,NERS<CRLF> Check Error None Check the error status
RPMV ID,RPMV,2000<CRLF> RPM Set RPM setting
PSIV ID,PSIV,25<CRLF> PSI Set PSI setting
BCDR ID,BCDR<CRLF> BCD RESET None Reset internal BCD
PHOS ID,PHOS,8<CRLF> Phase offset 0~15 Offset the phase
PCNT ID,PCNT<CRLF> Return Count Value None Check the print quantity
INKS ID,INKS,1000<CRLF> Ink Sensitivity Ink Sensitivity
MKUS ID,MKUS,1000<CRLF> Makeup Sensitivity Makeup Sensitivity

Version 2.0.0 Page 6


Communications Manual

CHAPTER 5 Message Command Description

ID will indicate the communication identification.

<CRLF> will indicate the Carriage Return+Line Feed character ( hex 0D 0A, decimal 13 10 ).

→ : send

 : feedback

Notice : Message 1 & Message 2 are default message, cannot be modified and deleted.

Command : ECHO Format : ID,Command<CRLF>


Description : Communication link status
PC Sequence T7
0,ECHO<CRLF> →
 0,ECHO<CRLF>

Command : PEEC Format : ID,Command,OPTION,<CRLF>


Description : Result after communication
OPTION : [ 0 ] accept, [ 1 ] no accept
PC Sequence T7
0,PEEC,1,<CRLF> →
 0,PEEC,1,<CRLF>

Command : MSLT Format : ID,Command<CRLF>


Description : Receive msg list
PC Sequence T7
0,MSLT<CRLF> →
 Format : ID,Message No(3),Field Cnt(2),message name<CRLF>

0,001,03,Default Message
0,002,06,Setting Message

Version 2.0.0 Page 7


Communications Manual

Command : MSST Format : ID,Command,Message No,<CRLF>


Description : Select printing msg
Sample : change msg 2 from msg 1 for printing
PC Sequence T7
0,MSST,2,<CRLF> →
 0,OK<CRLF>

Command : NMIF Format : ID,Command,<CRLF>


Description : Current printing msg field info
Message content : Field 1 ‘abc’, field 2 ‘def’
PC Sequence T7
0,NMIF,<CRLF> →
 Format : ID,[M:Field No(2)/Field
Cnt(2)][Ffont(2),Bbold(1),Sspace(2),X:position(4),Y:position(2)][Field Type,Field String]

0,[M:01/02][F08,B1,S01,X:0000,Y:00][TEXT,abc]
0,[M:02/02][F08,B1,S01,X:0000,Y:17][TEXT,def]

Command : SMFI Format : ID,Command,message No,<CRLF>


Description : Selected msg field info
Message no. 3 content : Field 1 ‘abc’, field 2 ‘def’
PC Sequence T7
0,SMFI,3,<CRLF> →
 Format : ID,[M:Field No(2)/Field
Cnt(2)][Ffont(2),Bbold(1),Sspace(2),X:position(4),Y:position(2)][Field Type,Field String]

0,[M:01/02][F08,B1,S01,X:0000,Y:00][TEXT,abc]
0,[M:02/02][F08,B1,S01,X:0000,Y:17][TEXT,def]

Version 2.0.0 Page 8


Communications Manual

Command : NMMD Format : ID,Command,Field No,TEXT^Field No,TEXT<CRLF>


* Special character to distinguish field in Format is ‘^’
Description : Modify current printing msg
Msg content : Field 1 ‘abc’, field 2 ‘def’, field 3 ‘ghi’
PC Sequence T7
Sample 1 : change content of field 1 as 123
0,NMMD,1,123<CRLF> →
 0,FDOK<CRLF>
Sample 2 : change content of field 2 as 456
0,NMMD,2,456<CRLF> →
 0,FDOK<CRLF>
Sample 3 : change content of field 1 as 123, AND change content of field 3 as 78
0,NMMD,1,123^3,78<CRLF> →
 0,FDOK<CRLF>

Command : SMFD Format : ID,Command,message No(3),Field No(2),<CRLF>


Description : Delete selected field of selected msg
Sample : delete field 2 from msg 3
PC Sequence T7
0,SMFD,003,02,<CRLF> →
 0,OK<CRLF>

Command : MSDT Format : ID,Command,message No,<CRLF>


Description : Delete selected msg
Sample : delete msg 3
PC Sequence T7
0,MSDT,3,<CRLF> →
 0,OK<CRLF>

Command : NMWT Format : ID,Command,message name,<CRLF>


Description : Write new msg ( only msg name without field))
Sample : write msg name ‘TT’
PC Sequence T7
0,NMWT,TT,<CRLF> →
 0,NMOK<CRLF>

Version 2.0.0 Page 9


Communications Manual

Command : SMFM
Format : ID,Command,Message No(3),Field No(2),Font(2),Bold(1),Space(2),X coordinate(4),Y coordinate(2),Field
Type,Field content<CRLF>
Description : Modify selected field of selected msg
Message&Field attribute
Msg no. 003 ( 3digits ) Field X coordinate 0000 ( 4digits )
Field no. 01 ( 2digits ) Field Y coordinate 00 ( 2digits )
Field font 16dots (08) (2digit) Field type TEXT
Field bold 1 ( 1digit ) Field contents Banana
Field space 01 ( 2digits )
Font-specific attribute description in Field
Attribute Font meaning Attribute Font meaning
00 5x5 09 16x12
02 7x5 10 19x14
04 9x7 12 24x18
06 12x8 14 32x20
07 14x8 15 32x24
08 16x10

Sample 1 Changes field 1 in msg 3 from Banana to


PC SEND 0,SMFM,003,01,08,1,01,0000,00,TEXT,Apple<CRLF>
Feedback 0,FDOK<CRLF>

Sample 2 Move X coordinate to 10 of field 1 in msg 3


PC SEND 0,SMFM,003,01,08,1,01,0010,00,TEXT,Banana<CRLF>
Feedback 0,FDOK<CRLF>

Sample 3 Change font to 24X18 of field 1 in msg 3


PC SEND 0,SMFM,003,01,12,1,01,0000,00,TEXT,Banana<CRLF>
Feedback 0,FDOK<CRLF>

Sample 4 Change bold to 2, Y coordinate to 5, content to Orange of field 1 in msg 3


PC SEND 0,SMFM,003,01,08,2,01,0000,05,TEXT,Orange<CRLF>
Feedback 0,FDOK<CRLF>

Version 2.0.0 Page 10


Communications Manual

Command : NFWT
Format : ID,Command,Message No(3),Font(2),Bold(1),Space(2),X coordinate(4),Y coordinate(2),Field type,Field
content<CRLF>
Description : Add new field
Message&Field attribute
Message no. 003 ( 3digits ) Field X coordinate 0100 ( 4 digits )
Field font 16dots(08) (2 digits) Field Y coordinate 00 ( 2 digits )
Field bold 1 ( 1 digits ) Field type TEXT
Field space 01 ( 2 digits ) Field contents Banana

Sample Add new field as above in msg 3


PC SEND 0,NFWT,003,08,1,01,0100,00,TEXT,Banana<CRLF>
Feedback 0,NFOK<CRLF>

Version 2.0.0 Page 11