PARAMETER LIST LC100

ORDER: 15-1337
SCHEMATIC NR.: 1337TEL0915
CUSTOMER: TELECOMPLET
OBJECT: TECH PARK – L2
DATE: 13.10.2015

Factory setting
TYPE Parameter Description Possible value
INIT User
A-1 Number of stops 2-40 5
GENERAL PARAMETERS TYPE

A-2 Number of elevators 1-8 1


A-3 Elevator marking A-H A
A-4 Evacuation program 0-2 1
A-5 Configuration LC100 I, VFD, Y, SR VFD
A

A-6 Configuration LC100 K, K2, V, V2 K, V2


A-7 Configuration LC100-E 0-7 0
A-8 Configuration LC100 ADL, ELG ADL
A-9 LC100-P, M, L A, B A
A-10 Type LC100-E 0-7 ---
B-1 Call process type 0-4 1
B-2 Priority time for car call 0-25 s 3.0
B-3 Program multiplex 1-2 1
B-4 Program A/B side 0-1 0
B-5 Program lift boy 0-1 0
CALL PROCESSING TYPE B

B-6 Main stop 1-A1 1


B-7 Fire stop zone 1 0-A1 0A
B-8 Fire stop zone 2 0-A1 0A
B-9 Fire stop zone 3 0-A1 0A
B-10 Fire stop zone 4 0-A1 0A
B-11 False calls erasing 0-A1 0
B-12 Parking type program 1-2 1
B-13 Parking stop 1 0-A1 0
B-14 Time for praking 1 0-41:40min 2:00
B-15 Parking stop 2 0-A1 0
B-16 Time for parking 2 0-41:40min 0:00
B-17 Call denied 0-232 0:00
B-18 Cancel cabine calls 0/1 0
C-1 Main drive type 1-4 3
C-2 Speed V1 VMRPI V
C-3 Speed V2 VMRPI ---
C-4 Speed V3 VMRPI ---
C-5 Stopping speed VMRPI ---
C-6 Relevelling speed VMRPI ---
C-7 Inspection speed 1 VMRPI M
C-8 Inspection speed 2 0-2,5 s ---
C-9 Time for switching off the drive contactors 0-25 s 0.0
MAIN DRIVE TYPE C

C-10 Time for switching on the brake contactor 0-2,5 s 0.0


C-11 Time for switching off the brake contactor 0-2,5 s 0.0
C-12 Time for brake holding voltage 0-25 s 2.0
C-13 Working time for main drive fan 0-250 s 30
C-14 Starting time for motor pump 0-25 s 2.0
C-15 Inspection speed 0-1 0
C-16 Time for valve UP function 0-2,5 s 0.00
C-17 Additional time for motor pump 0-2,5 s 0.00
C-18 Relevelling 0-2 0
C-19 Additional time for relevelling 0-2,5 s 0.00
C-20 Open brake time in evacuation 0-2,5 s 0.02
C-21 Closed brake time in evacuation 0-2,5 s 0.00
C-22 I-valve delay UP 0-2,5 s 0.00
C-23 I-valve delay DOWN 0-2,5 s 0.00
Factory setting
TYPE Parameter Description Possible value
INIT User
D-1 Car door 0-2 1
D-2 A-side door for stops 1-8 1-8 ---
D-3 A-side door for stops 9-16 9-16 ---
D-4 A-side door for stops 17-24 17-24 ---
D-5 A-side door for stops 25-32 25-32 ---
D-6 A-side door for stops 33-40 33-40 ---
D-7 B-side door for stops 1-8 1-8 ---
D-8 B-side door for stops 9-16 9-16 ---
D-9 B-side door for stops 17-24 17-24 ---
D-10 B-side door for stops 25-32 25-32 ---
D-11 B-side door for stops 33-40 33-40 ---
D-12 Orders door A ABCDEF AC
D-13 A-side door opening time 0-25 s 4.0
D-14 A-side landing door type 0-3 1
D-15 A-side automatic door open in stops 1-8 1-8 ---
D-16 A-side automatic door open in stops 9-16 9-16 ---
DOORS TYPE D

D-17 A-side automatic door open in stops 17-24 17-24 ---


D-18 A-side automatic door open in stops 25-32 25-32 ---
D-19 A-side automatic door open in stops 33-40 33-40 ---
D-20 Orders door B ABCDEF ---
D-21 B-side door opening time 0-25 s 4
D-22 B-side landing door 0-3 0
D-23 B-side automatic door open in stops 1-8 1-8 ---
D-24 B-side automatic door open in stops 9-16 9-16 ---
D-25 B-side automatic door open in stops 17-24 17-24 ---
D-26 B-side automatic door open in stops 25-32 25-32 ---
D-27 B-side automatic door open in stops 33-40 33-40 ---
D-28 Preopening 0-1 0
D-29 Preopening delay 0-2,5 s 0.00
D-30 Passenger passing time 0-25 s 5.0
D-31 Passenger passing time after photocell 0-25 s 2.0
D-32 Passenger passing time after cabin call 1-25 s 1.0
D-33 Door deceleration time 0-25 s 1.0
D-34 Door reversing time 0-2,5 s 0.05
D-35 Door resistors time 0-25 s 0.0
D-36 Door locking time 0-2,5 s 1
E-1 Positioning type 1-5 4
E-2 First drive direction 0-1 0
E-3 Decelerating zone correction 0-250imp 0
E-4 Preopening speed 0-100imp/s 0
E-5 Stopping delay in direction UP 0-2,5 s 0.00
POSITIONING TYPE E

E-6 Stopping delay in direction DOWN 0-2,5 s 0.00


E-7 Short floor distance 1-8 1-8 ---
E-8 Short floor distance 9-16 9-16 ---
E-9 Short floor distance 17-24 17-24 ---
E-10 Short floor distance 25-32 25-32 ---
E-11 Short floor distance 33-40 33-40 ---
E-12 Deceleration zone for V2 0-100imp 1
E-13 Deceleration zone for V3 0-100imp 1
E-14 Condition for V2 0-100imp 1
E-15 Condition for V3 0-100imp 1
E-16 Learning drive 0-3 0
Factory setting
TYPE Parameter Description Possible value
INIT User
F-X Stopping correction for stop x 2-2,55 s 0s
Stopping correction is intialy set to 0 s, user sets the values:
F-01 F-11 F-21 F-31
F-02 F-12 F-22 F-32
STOPPIN TYPE F

F-03 F-13 F-23 F-33


F-04 F-14 F-24 F-34
F-05 F-15 F-25 F-35
F-06 F-16 F-26 F-36
F-07 F-17 F-27 F-37
F-08 F-18 F-28 F-38
F-09 F-19 F-29 F-39
F-10 F-20 F-30 F-40
G-X Stop marking 0-9, A-Z, a-z, +, -, …
G-00 S G-10 G-20 G-30
G-01 0 G-11 G-21 G-31
G-02 1 G-12 G-22 G-32
G-03 2 G-13 G-23 G-33
TYPE G

G-04 3 G-14 G-24 G-34


G-05 4 G-15 G-25 G-35
G-06 G-16 G-26 G-36
G-07 G-17 G-27 G-37
G-08 G-18 G-28 G-38
G-09 G-19 G-29 G-39
H-1 Car fan type 1-2 1
H-2 Working time for car fan 0-250s 30
H-3 Car light type 1-2 1
H-4 Working time for car light 0-250s 30
H-5 OFF time for shaft light 0-250s 10:00
H-6 Programable relay T1 --- ---
TIMERS TYPE H

H-8 Programable relay T2 --- ---


H-10 GONG signal duration 0-2,55s 0,03
H-11 UNLOCKING signal duration 0-25s 0.0
H-12 PHOTOCELL signal activation 0-250s 20
H-13 CLOSING OBSTACLES signal activation 0-250s 30
H-14 STOP signal activation 0-41:40min 3:20
H-15 LANDING DOOR signal activation 0-41:40min 10:00
H-16 Energy saving mode 0-1 1
H-17 Energy saving time 0-250s 10:00
H-18 Delay off for function 58 0-3s 0
H-19 Acceleration time (for time positioning) 0-20s
0-9999W0- 0
I-1 Cold state PTC resistance 9999W0-
0-9999W0- 700
I-2 Warm state PTC resistance 9999W0-9999W
9999W0- 1620
I-3 Normal travel max. Time 9999W0-9999W
0-250s 20
I-4 Leveling max. Time 0-250s 20
PROTECTION TYPE I

I-5 Releveling max. Time 0-250s 20


I-6 Evacuation max. Time 0-250s 120
I-7 Maximal time for door opening 0-25s 10.0
I-8 Maximal time for door closing 0-25s 10.0
I-9 Maximal time for locking the doors 0-25s 3.0
I-10 Temperature for switching off the control board 0-85°C 0
I-11 Temperature for switching on the control board 0-85°C 0
I-12 Temperature for switching the control board fan ON 0-85°C 50
I-13 Temperature for switching the control board fan OFF 0-85°C 40
Description Description

Boar
TYP
Pin Pin

d
E ID; Parameter: Pol: ID; Parameter: Pol:
XC5.1 NO XC8.1 NO
XC5.2 NO XC10.1 NOR
XC5.3 NO XC10.2 FO-032; SHAFT LIGHT NOR
CONFIGURATION TYPE N

XC5.4 NO XC10.3 NOR


XC5.5 NO XC10.4 NOR
XC5.6 NO XC10.5 NOR
LC100-C

XC5.7 FI-207; Evacuation NO XC10.6 NOR


XC5.8 NO XC10.7 NOR
XC5.9 NO XC10.8 NOR
XC5.10 FI-210; Fire program zone 1 NC
XC6.1 FI-201; Recall program NC
XC6.2 FI-202; Recall up NO
XC6.3 FI-203; Recall down NO
Board

TYP Description Description


Pin Pin
E ID; Parameter: Pol: ID; Parameter: Pol:
XK4.1 NO XK9.1 FO-051; CAR LIGHT ORDER INV
XK4.2 NO XK9.2 FO-050; CAR FAN ORDER NOR
XK4.3 NO XK9.3 FO-040; OPENING DOOR A NOR
XK5.1 FI-235; Inspection drive NC XK9.4 FO-041; CLOSING DOOR A NOR
CONFIGURATION TYPE N

XK5.2 FI-236; Inspection drive UP NO XK9.5 FO-053; ALARM ENABLE INV


XK5.3 FI-237; Inspection drive DOWN NO XK9.6 NOR
XK6.1 FI-250; Reference UP 1 NO XK9.7 NOR
LC100-K

XK6.2 FI-252; Reference DOWN 1 NO XK9.8 NOR


XK6.4 NO XK10.1 FI-260; Opening limit door A NC
XK6.5 NO XK10.2 FI-261; Closing limit door A NC
XK6.7 FI-256; Stopping UP NO XK10.3 FI-262; Obstacle door A NO
XK6.8 NO XK10.6 FI-263; Photocell door A NO
XK6.9 NO XK11.1 NC
XK11.2 NC
XK11.3 NO
XK11.6 NO
Board

TYP Description Description


Pin Pin
E ID; Parameter: Pol: ID; Parameter: Pol:
XE3.1 FA-401; Cabin call 1A NO XE4.1 NO
XE3.2 FA-402; Cabin call 2A NO XE4.2 NO
XE3.3 FA-403; Cabin call 3A NO XE4.3 NO
XE3.4 FA-404; Cabin call 4A NO XE4.4 NO
CONFIGURATION TYPE N

XE3.5 FA-405; Cabin call 5A NO XE4.5 FA-561; Car fan NO


XE3.6 NO XE4.6 FI-264; Open button door A NO
XE3.7 NO XE4.7 FI-265; Close button door A NO
LC100-E0

XE3.8 NO XE4.8 NO
XE5.1 NO XE6.1 NO
XE5.2 NO XE6.2 NO
XE5.3 NO XE6.3 NO
XE5.4 NO XE6.4 NO
XE5.5 NO XE6.5 NO
XE6.6 NO
XE6.7 NO
XE6.8 NO
Board

TYP Description Description


Pin Pin
E ID; Parameter: Pol: ID; Parameter: Pol:
CONFIGURATION TYPE N

XF3.1 NO XF4.1 NO
XF3.2 NO XF4.2 NO
LC100-FC(E0)

XF3.3 NO XF4.3 NO
XF3.4 NO XF4.4 NO
XF3.5 NO XF4.5 NO
XF3.6 NO XF4.6 NO
XF3.7 NO XF4.7 NO
XF3.8 NO XF4.8 NO
Board
TYP Description Descritption
Pin Pin
E ID; Parameter: Pol: ID; Parameter: Pol:
XE3.1 NO XE4.1 NO
XE3.2 NO XE4.2 NO
XE3.3 NO XE4.3 NO
XE3.4 NO XE4.4 NO
CONFIGURATION TYPE N

XE3.5 NO XE4.5 NO
XE3.6 NO XE4.6 NO
XE3.7 NO XE4.7 NO
LC100-E1

XE3.8 NO XE4.8 NO
XE5.1 NO XE6.1 NO
XE5.2 NO XE6.2 NO
XE5.3 NO XE6.3 NO
XE5.4 NO XE6.4 NO
XE5.5 NO XE6.5 NO
XE6.6 NO
XE6.7 NO
XE6.8 NO
Board

TYP Description Description


Pin Pin
E ID; Parameter: Pol: ID; Parameter: Pol:
CONFIGURATION TYPE N

XF3.1 NO XF4.1 NO
XF3.2 NO XF4.2 NO
LC100-FC(E1)

XF3.3 NO XF4.3 NO
XF3.4 NO XF4.4 NO
XF3.5 NO XF4.5 NO
XF3.6 NO XF4.6 NO
XF3.7 NO XF4.7 NO
XF3.8 NO XF4.8 NO
Board

TYP Description Description


Pin Pin
E ID; Parameter: Pol: ID; Parameter: Pol:
XI3.3 NO XI6.2 NOR
XI3.4 NO XI6.3 NOR
CONFIGURATION TYPE N

XI3.5 NO XI6.4 NOR


XI3.6 NO XI6.5 NOR
XI3.7 NO XI6.6 NOR
LC100-I

XI3.8 NO XI6.7 NOR


XI3.9 NO XI6.8 NOR
XI3.10 NO XI6.9 NOR
XI4.1,2 NOR
XI4.3,4 NOR
XI4.5,6 NOR
XI4.7,8 NOR

Description Descritption
Boar

TYP
Pin Pin
d

E ID; Parameter: Pol: ID; Parameter: Pol:


X7.1,2 FO-019; SUPPLY CONTACTOR NO X7.5,6 NO
VFD

N
X7.3,4 FO-020; UPS CONTACTOR NO X7.7,8 NO
Factory setting
TYPE Parameter Description Possible value
INIT User
P-xx Configuration P or M module A-H, V
P-00 –configuration for car module, P-xx – configuration for landing modules
P-00 ABDFG F-10 AB F-20 AB F-30 AB
PML MODULE TYPE P

P-01 AB F-11 AB F-21 AB F-31 AB


P-02 AB F-12 AB F-22 AB F-32 AB
P-03 AB F-13 AB F-23 AB F-33 AB
P-04 AB F-14 AB F-24 AB F-34 AB
P-05 AB F-15 AB F-25 AB F-35 AB
P-06 AB F-16 AB F-26 AB F-36 AB
P-07 AB F-17 AB F-27 AB F-37 AB
P-08 AB F-18 AB F-28 AB F-38 AB
P-09 AB F-19 AB F-29 AB F-39 AB

Factory setting
TYPE Parameter Description Possible value
INIT User
T-01 Standard 1-3 1
T-02 Time for starting the inverter 0-25s 5s
T-03 Time for powering the main supply contactor 0-25s 5s
T-04 Time for powering the UPS contactor 0-25s 5s
T-05 Time for start motor conntactors 0-2s 1s
T-06 Next service DAY 0-31 0
T-07 Next service MONTH 0-12 0
T-08 Next service YEAR 0-99 0
T-09 Monitoring type 0/1 1
FACTORY TYPE T

T-10 Baud rate CAN 0/1 0


T-11 Factory settings A-H ---
T-12 Output tables bing/gray codes 0/1, 0/1 0,1
T-13 Simulator enable 0/1 0
T-14 Control time valve down A3 0–2,5 s 0,5
T-15 Delay on order direction ALGI 0–2,5 s 0,5
T-16 ADL configuration A-H ---
T-17 Stop NORM 2454-2 0-40 0
T-18 Drive NORM 2454-2 0-100 0
T-19 VFD config A-H ---
T-20 Factory settings A-H ---
T-21 Reserved 0-255 0
T-22 Reserved 0-255 0
T-23 Impulse resolution 0-60000 0