Lesson 6 Updated
Lesson 6 Updated
2
Introduction
4
NOTICE (WN)
• The WARNING signal word is appropriate for signs placed outside of the area.
.مناسبة لإلشارات الموضوعة خارج المنطقة كلمة إشارة تحذير
5
• Indicates a potentially hazardous situation which, if not avoided.
إذا لم يتم تجنبه،• يشير إلى موقف يحتمل أن يكون خطرا
6
Indicates a statement of company policy directly or indirectly
related to the safety of personnel or protection of property
يشير إلى بيان لسياسة الشركة يتعلق بشكل مباشر أو غير مباشر بسالمة الموظفين أو حماية
الممتلكات
7
• Used to indicate general instructions relative to safe work practices.
.تستخدم لإلشارة إلى التعليمات العامة المتعلقة بممارسات العمل اآلمنة
• Remind of proper safety procedures.
.تذكير إجراءات السالمة المناسبة
• Indicate the location of safety equipment.
.تحدد موقع معدات السالمة
8
• used to indicate the location of emergency firefighting equipment.
تستخدم لإلشارة إلى موقع معدات مكافحة الحرائق في حاالت الطوارئ
9
High voltage area
منطقة جهد عالي
Electricity hazards
مخاطر كهربية
Bio hazards
مخاطر بيولوجية
Fire exits
مخرج في حال الحريق
Where are fire extinguisher
أين توجد طفايات الحريق
Restricted areas or employees only
منطقة محظورة أو للموظفين فقط
No smoking
10
ممنوع التدخين
Best Sign Story
فيديو
2015 NFPA 70E- Safe Electrical Work Practices
12
13
Sign Type And Content Selection Flow Chart
14
15
SAFETY BARRIER: (SB)
16
Barriers help keep people or products inside and help keep non employees out.
العوائق تساعد على إبقاء الناس أو المنتجات في الداخل وتساعد على إبقاء غير الموظفين خارج.
17
1- HV TEST BARRIERS
حواجز الختبارات الجهد العالي
19
They are Yellow and Black, and used with signs to define the
boundaries of the permit area.
تكون صفراء مع أسود و تستخدم مع اإلشارات لتحدد الحدود للمنطقة المسموح
فيها
20
They are Orange.
يكون لونها برتقالي
21
حاجز خارج (قفص الجهد العالي)
22
حاجز في (منطقة عمل معينة)
23
Demarcation
24
Electrical Equipment
25
Fire Equipment
26
Stacking and Storage
27
Outside Storage
28
WORK AREAS
29
STAIRS
• The edge of each step should be clearly demarcated with a standard width (5cm)
yellow demarcation line to indicate a change in level,
(5cm) خطوط
صفراء
30
31
DOORS
32
Work at Height
33
Work at Height
34
Work at Height
Barriers and warning signs must be posted while lifting materials or carrying
out in high places in order to avoid the fall of an
Workers are required to use safety belts and straps when working at the top
of poles, steel structures, ladders.
35
Work at Height
Workers who stay down shall have to monitor the work going on at
high level places and shall take caution and care to avoid the danger
of falling objects.
Those who have acrophobia must not carry out works at height .
36
Work at Height
37
Ladders
38
Ladders
Ladders
1- Portable Ladders
39
LADDERS
40
LADDERS
41
Ladders
Ladders used to reach the roof must extend for at least one meter above
the supporting point.
42
Ladders
1- Portable Ladders
The horizontal distance between the wall and the ladder foot must be
about one quarter of the extended length of the ladder.
43
Ladders
Insulated ladders must be used in all electric works.
44
Scaffolds
45
Scaffolds
Scaffolds must be able to support without failure, a load equals 4 times the
maximum intended load.
46
47
Scaffolds
Scaffolds and other similar devices must be maintained in a safe condition and must
not be changed or horizontally moved when in use.
48
Scaffolds
Before using the scaffold, it must be examined and checked by the safety section.
49
Scaffolds
All planking- الواح خشبية-of platforms shall be overlapped (minimum 30 cm), or
secured from movement.
Employees are not allowed to work on scaffolds during unstable weather conditions.
50
Scaffolds
Wires or fiber ropes for scaffolds must be able to support at least six (6) times
the intended load.
51
Excavation Works
52
Excavation Works
Must be very careful when excavating in areas with underground facilities and the
excavation must be manually when approaching to the facilities.
Do not use mechanical excavation equipment except in the areas that have no
danger of contacting electrical cables or damaging other facilities.
53