Condiciones para la bomba 1.

Q [L/s]= 120 hf [m]= 5.2 E [mm]= 0.0015


Q [m^3/s]= 0.12 L [m]= 286 E [m]= 0.0000015

v [m^2/s]= 0.00000117 D [pul]= 4 HT [m]= 37


D [m]= 0.1016

H sistema H bomba
Q [m^3/s] Re E/D F H [m] H [m]
0 0 0.00001476 0 37.0 850
0.01 107110.1306 0.00001476 0.017817238 41.3 833.8833
0.02 214220.2612 0.00001476 0.017817261 54.2 814.6732
0.03 321330.3919 0.00001476 0.015337225 70.8 792.3697
0.04 428440.5225 0.00001476 0.01435233 93.6 766.9728
0.05 535550.6531 0.00001476 0.013668544 121.7 738.4825
0.06 642660.7837 0.00001476 0.013176115 155.1 706.8988
0.07 749770.9144 0.00001476 0.012795668 193.6 672.2217
0.08 856881.045 0.00001476 0.012489613 237.3 634.4512
0.09 963991.1756 0.00001476 0.012235938 286.0 593.5873
0.1 1071101.306 0.00001476 0.012020921 339.7 549.63
0.11 1178211.437 0.00001476 0.01183546 398.4 502.5793
0.12 1285321.567 0.00001476 0.011673239 462.0 452.4352
0.13 1392431.698 0.00001476 0.011529707 530.5 399.1977
0.14 1499541.829 0.00001476 0.011401488 603.8 342.8668

Q vs H
900.0
800.0
700.0
600.0
500.0
H [m]

400.0 Ec. sistema


300.0 Ec. Bomba
200.0
100.0
0.0
0 0.02 0.04 0.06 0.08 0.1 0.12 0.14 0.16
Q [m^3/s]
Condiciones para la bomba 2.

Q [L/s]= 120 hf [m]= 5.2 E [mm]= 0.0015


Q [m^3/s]= 0.12 L [m]= 286 E [m]= 0.0000015

v [m^2/s]= 0.00000117 D [pul]= 6 HT [m]= 37


D [m]= 0.1524

H sistema H bomba
Q [m^3/s] Re E/D F H [m] H [m]
0 0 0.00000984 0 37.0 180
0.01 71406.75375 0.00000984 0.019364956 37.6 178.631
0.02 142813.5075 0.00000984 0.019364969 39.5 176.312
0.03 214220.2612 0.00000984 0.016524774 42.0 173.043
0.04 285627.015 0.00000984 0.015410099 45.4 168.824
0.05 357033.7687 0.00000984 0.014628122 49.5 163.655
0.06 428440.5225 0.00000984 0.014063322 54.4 157.536
0.07 499847.2762 0.00000984 0.013624914 60.1 150.467
0.08 571254.03 0.00000984 0.01327065 66.5 142.448
0.09 642660.7837 0.00000984 0.012975678 73.7 133.479
0.1 714067.5375 0.00000984 0.012724519 81.5 123.56
0.11 785474.2912 0.00000984 0.012506903 90.1 112.691
0.12 856881.045 0.00000984 0.012315698 99.4 100.872
0.13 928287.7987 0.00000984 0.012145768 109.5 88.103
0.14 999694.5525 0.00000984 0.011993297 120.2 74.384

Q vs H
200.0
180.0
160.0
140.0
120.0
H [m]

100.0
80.0 Ec. sistema
60.0 Ec. Bomba
40.0
20.0
0.0
0 0.05 0.1 0.15
Q [m^3/s]
Condiciones para la bomba 3.

Q [L/s]= 120 hf [m]= 5.2 E [mm]= 0.0015


Q [m^3/s]= 0.12 L [m]= 286 E [m]= 0.0000015

v [m^2/s]= 0.00000117 D [pul]= 8 HT [m]= 37


D [m]= 0.2032

H sistema H bomba
Q [m^3/s] Re E/D F H [m] H [m]
0 0 0.00000738 0 37.0 87
0.01 53555.06531 0.00000738 0.020602549 37.2 86.7628
0.02 107110.1306 0.00000738 0.020602557 37.7 86.0566
0.03 160665.1959 0.00000738 0.017479537 38.3 84.8814
0.04 214220.2612 0.00000738 0.016267096 39.2 83.2372
0.05 267775.3266 0.00000738 0.015412077 40.3 81.124
0.06 321330.3919 0.00000738 0.014794555 41.5 78.5418
0.07 374885.4572 0.00000738 0.014314598 43.0 75.4906
0.08 428440.5225 0.00000738 0.013926282 44.7 71.9704
0.09 481995.5878 0.00000738 0.013602519 46.6 67.9812
0.1 535550.6531 0.00000738 0.013326454 48.6 63.523
0.11 589105.7184 0.00000738 0.013086908 50.9 58.5958
0.12 642660.7837 0.00000738 0.012876119 53.3 53.1996
0.13 696215.849 0.00000738 0.012688496 55.9 47.3344
0.14 749770.9144 0.00000738 0.012519891 58.7 41.0002

Q vs H
100.0
90.0
80.0
70.0
60.0
H [m]

50.0
Ec. sistema
40.0
30.0 Ec. Bomba
20.0
10.0
0.0
0 0.05 0.1 0.15
Q [m^3/s]
Desde el punto de vista hidráulico, se pueden tomar las determinaciones correspondientes a partir
de los siguientes criterios.

Caudal: El caudal es la cantidad de líquido que la bomba puede mover en un determinado período
de tiempo. Es importante elegir una bomba con un caudal adecuado para las necesidades del
sistema.

Altura de elevación: La altura de elevación es la distancia vertical entre la superficie del líquido y el
punto más alto de la tubería. Es importante elegir una bomba con una altura de elevación
suficiente para alcanzar la altura requerida en el sistema.

Presión: La presión es la fuerza por unidad de área que ejerce el líquido. Es importante elegir una
bomba que pueda proporcionar la presión adecuada para el sistema.

Eficiencia: La eficiencia de una bomba es la relación entre la potencia de salida y la potencia de


entrada. Es importante elegir una bomba que tenga una alta eficiencia para minimizar los costos

Por lo anteriormente expuesto, se puede determinar que la mejor condición que contiene la
relación adecuada de calidad y precio, corresponde a la bomba con diámetro 8 pulgadas.