You are on page 1of 22

FINE AUTOMATION

BY-PASS LEVEL INDICATOR


TEL: 886-2-26894607, 26886025 FAX: 886-2-26894533, 26883318
http: //www.fineautomation.com e-mail: L2923@m s15.hinet. net

Introduction Applications And Features

The By-Pass Level Indicator is installed outside of a ves 1. Applicable in environments with high temp., high pres-
sel or tank. The liquid level in the tank can easily be sure, strong acid, strong alkali and hazardous locations.
obtained by reading the flag color. The magnetic The structure is simple but durable and reliable. It is
switches and level transducer are option for electrical sig also with various optional devices for upgrade in use.
nal output and level transmitting for remote control. 2. A Level Transducer or Magnetic Switches can be
installed and adjusted with no need to stop any process.
3. It is not operated by electricity and with not be affected
by power failure.
Principle
4. The flag display is scaled by a piece of color, division
every 10cm, one can easily read the levels height.
By bypassing a liquid to the outside chamber, taking
advantage of a float inside the chamber with a magnet 5. Multiple applications for textile dyeing, sewage water
inserted as well as in the color flags, one can reveal the processing, power generating, hot coal oil boiler and pet-
level of the liquid in a tank as the flags turn and change rochemical industries.
color by magnetic attraction to the float.

Flag

By-pass
Chamber

Magnet

Float

1
PRODUCT WITH PATENT RECOMMENDATION

1.) Magnetic Switch


* The plastic miniature magnetic switch is anti-corrosive
and with IP67 rating. It's the smallest magnetic switch TYPE:BP-9-B1L
in the world.
* The mini switch is with ease of setting up and real time
adjustment.

2.) Innovative Bottom End and the


Connecting Flange
* The lower center duct is at the bottom end of the cham-
ber, when the liquid in the tank drains, there will be no
remainder in the chamber unit.
* This is suitable for productions require frequent materi- Patent No.:135002
als modification or not mixture allowed during the pro-
cess.

3.) Removable Duct and


Connecting Flange
1
* The flanges setting is close to the two ends of chamber, Innovative Bottom End and the
"C-C" distance is maximized in length. Connecting Flange
* It is strengthened in the structure by large phase weld.
* While in installation, it is available to adjust the flange
to fit the mounting holes, with ease of mounting.

Patent No.:137824

Magnetic Switch 3
2
Patent No.:149292
DE: L97230220.4
CN: Nr 298 01 501.3

2
Plastic Standard Type
BP999B1H BP999B1K BP999B2K BP999B7H
1/2"plug 1/2"plug
1/2"plug 1/2"plug

100

100
100

100
95 80
95
267

C-C
C-C
C-C

C-C
140
140

140
140

120
120

1/2"plug
1/2"plug
1/2"PT
1/2"PT

Specifications:
TYPE
Description BP999B1H BP999B1K BP999B2K BP999B7H

Top End Flat top with 1/2"PT plug

Dual flange Dual flange


Bottom End Dual flange with 1/2" drain valve
with 1/2"PT plug with 1/2"PT plug
3/4" or 1"PT 3/4" x10kg/cm2
Connecting 3/4" x10kg/cm2 (Flange) (Screw) (Ball Valve)

C-C Distance Min. 150mm; Max. 3800mm

Operation Pressure 5kg/cm2

Operation Temp. PP: 80BC, PVDF: 120BC

Chamber PP: f60.5 x 3.8t, PVDF: f63 x 3.2t

Float Type BPB-2500/2510 (see page 8)

Material PP/PVDF

Flag Indicator BPB-0700/0720 (see page 10)

Ruler BPA-2130/2140 (see page 13)

3
BY-PASS LEVEL INDICATOR TYPICAL INSTALLATION

BP999C1H
1/2"plug
100

95
C-C
140

1/2"plug

STYLE A1L (ANGEL PIPE)

BP999C1H
Dual flange
with 1/2"PT plug
Dual flange
with 1/2"PT plug

3/4" x10kg/cm2 (Flange)

Min. 150mm;
Max. 3800mm

5kg/cm2

PP: 80BC, PVDF: 120BC STYLE A5M (TANK TOP)

PP: f60.5 x 3.8t,


PVDF:f63 x 3.2t
BPB-2500/2510
(see page 8)
STYLE CIH (SIDE FLANGE)
PP/PVDF

BPB-0700/0720
(see page 10)
BPA-2130/2140
(see page 13)

4
Metal Standard Type
BPA99A1H BPA99A5M BPA99B1H BPA99B1K
1/2"plug
1/2"plug

100
100

100

100
95 95
95

C-C
C-C

C-C
160

160
160

160
3" Pipe
B

120
1/2"plug
1/2"plug
1/2" Valve

Specifications:
TYPE
Description
BPA99A1H BPA99A5M BPA99B1H BPA99B1K

Top End Cap Flat top with 1/2"PT plug

Dual flange Dual flange with Dual flange Dual flange


Bottom End with 1/2"PT plug 3"shield pipe with 1/2"PT plug with 1/2" drain valve

Bottom Flange 1-1/2" x 5kg/cm2 3" x 5kg/cm2 1-1/2" x 5kg/cm2

Connecting 3/4" x10kg/cm2 (Flange) 2-1/2" (Hole) 3/4" x10kg/cm2 (Flange)

C-C Distance Min. 150mm; Min. 150mm; Min. 150mm; Max. 5800mm
Flag Display Length(L) Max. 5800mm Max. 2000mm

Operation Pressure 25kg/cm2 (Max. 50kg/cm2) 20kg/cm2

SUS304: 140BC, 200BC, 400BC SUS304: 140BC, 200BC,350BC


Operation Temp.
SUS316: 140BC, 200BC, 400BC SUS316: 140BC, 200BC,350BC

Chamber f60.5 x 2.8t

Float Type BPB-2560 (see page 9)

Material SUS304/SUS316

Flag Indicator BPB-0700/0720 Max. 200BC, BPB-0710/0730 Max. 400BC (see page 10)

Ruler BPA-2110/2120 (see page 13)

5
Metal Standard Type
BPA99B2K BPA99B7H BPA99C1H BPA99C8H

1/2"plug 1/2"plug 1/2"plug 1/2"plug

100
100

1/2"plug

100

100
95 215
95 95
C-C

C-C

C-C

C-C
160

1/2"plug

160

160
160
120

1/2"plug 1/2"plug 1/2"plug


1/2" Valve

Specifications:
TYPE BPA99B2K BPA99B7H BPA99C1H BPA99C8H
Description

Top End Flat top with 1/2"PT plug Dual flange with 1/2"PT plug

Dual flange
Bottom End with 1/2" drain valve Dual flange with 1/2"PT plug

Bottom Flange 1-1/2" x 5kg/cm2 2-1/2" x 5kg/cm2

Connecting 3/4"PT or 1"PT (Screw) 3/4" x10kg/cm2 (Flange) 1-1/4"x10kg/cm2(Flange)

C-C Distance Min. 150mm; Max. 5800mm

Operation Pressure 20kg/cm2 10kg/cm2 25kg/cm2 (Max. 50kg/cm2)

SUS304: 140BC, 200BC, 350BC SUS304: 140BC, 200BC,400BC SUS304: 140BC, 200BC,350BC
Operation Temp. SUS316: 140BC, 200BC,400BC SUS316: 140BC, 200BC,350BC
SUS316: 140BC, 200BC, 350BC
Jacket f76 x 3.0t
Chamber f60.5 x 2.8t
1/2"PT plug

Float Type BPB-2560 (see page 9)

Material SUS304/SUS316

Flag Indicator BPB-0700/0720 Max. 200BC, BPB-0710/0730 Max. 400BC (see page 10)

Ruler BPA-2110/2120 (see page 13)

6
Metal For Dyeing Type Metal High Pressure Type
BPC99B1L BP-99C1H
1/2"plug
1/2"plug
100

100
95 95

C-C
C-C

140
150

1-1/2"35kg/cm2
1/2"plug

Specifications:
TYPE
Description BPC99B1L BP-99C1H
Dual flange
Top End Flat top with 1/2"PT plug
with 1/2"PT plug
Dual flange
Bottom End Dual flange with 1/2"PT plug
with angle pipe

Connecting 3/4" x10kg/cm2 (Flange) 3/4" x 600Lb (Flange)

C-C Distance Min. 400mm; Max. 5800mm Min. 150mm; Max. 5800mm

Operation Pressure 25kg/cm2 100kg/cm2

SUS304: 140BC, 200BC SUS304: 140BC


Operation Temp.
SUS316: 140BC, 200BC SUS316: 140BC

Chamber f60.5 x 2.8t f65 x 3.5t

Float Type BPB-2580 (see page 9) BPB-2600 (see page 9)

Material SUS304/SUS316

Flag Indicator BPB-0700/0720 Max. 200BC BPB-0710/0720 Max. 200BC (see page10)

Ruler BPA-2110 /2120 (see page 13)

7
PLASTIC FLOAT SPECIFICATIONS

Specifications:
Spec.
Operation Temp. Max. Pressure Dimension S.G. Float length Material Weight
Type

BPB-2500 120 BC 5 kg/cm2 f 51x174 0.75 112 mm PVDF 200 g

BPB-2510 80 BC 5 kg/cm2 f 48x150 0.7 108 mm PP 188 g

*Specified S.G. are available made to order.

f51

f48
174

150
112

108

TYPE: BPB-2500 (PVDF) TYPE: BPB-2510 (PP)

8
METAL FLOAT SPECIFICATIONS

Specifications:
Spec.
Type Operation Temp. Max. Pressure Dimension S.G. Float length Material Weight

BPB-2540 400BC 30 kg/cm


2
f50x200 0.7 140 mm SUS316 227 g
BPB-2560 400BC 30 kg/cm
2
f50x175 0.75 131 mm SUS316 220 g
2
BPB-2580 400BC 40 kg/cm f50x150 0.87 130 mm SUS316 207 g

BPB-2591 400BC kg/cm 2


f50x177 0.87 124 mm SUS316 210 g

2
BPB-2600 400BC 40 kg/cm f50x140 0.6 180 mm SUS316 276 g
2
BPB-2620 400BC 25 kg/cm f50x140 0.6 84 mm Titanium 129 g

f50
f50

f50
200

175

150
130

120

105

TYPE: BPB-2540 TYPE: BPB-2560 TYPE: BPB-2580


f50

f50

f50
27

300

140
150

255
124

100

TYPE: BPB-2591 TYPE: BPB-2600 TYPE: BPB-2620


*The dotted line is the Magnet location.

9
FLAG DISPLAY

TYPE: BPB-0700 16.5


18
1. Housing material : SUS 304 10
f4.3
2. Flag Material : Engineer plastic
3. Flag Color : Red / White; Green / White
faco
4. Cover Material : Engineering plastics
5. Operate Temp. : -20~200BC
6. Standard Unit : 50mm

L=5800(MAX.)
TYPE: BPB-0710
1. Housing material : SUS 304
2. Flag Material : Copper
3. Flag Color : Golden / Silver
4. Cover Material : Glass
5. Operate Temp. : -20~400BC faco 8

6. Standard Unit : 50mm 14


9
26.5

TYPE: BPB-0720
21
1. Housing material : Aluminum f6.5
2. Flag Material : Engineer plastic
3. Flag Color : Red / White; Green / White
faco
4. Cover Material : Engineering plastics
5. Operate Temp. : -20~200BC
6. Standard Unit : 50mm
L=5800(MAX.)

TYPE: BPB-0730
5.5
1. Housing material : Aluminum
2. Flag Material : Copper 9.8

3. Flag Color : Golden / Silver


faco 10
4. Cover Material : Glass
5. Operate Temp. : -20~400BC 18 10.5
6. Standard Unit : 50mm 14 12

45 23

10
BALL VALVE

TYPE: LN-010 TYPE: LN-029


90 PART LN-010 LN-021 LN-022
1 Body Material SUS316 PP PVDF
42
2

1/2"PT
Working Temp. 150BC 80BC 120BC
1/2"PT

3 Connecting 1/2"PT 1/2"PT


2 2
57 152 4 Working Pres. 20kg/cm 5kg/cm

TYPE: LN-9 30
PART LN-930
DIMENSIONS
SIZE 1 BODY MATERIAL SUS304
3/4" 1"
D CODE
A, B ACCORDING TO JIS 10K 2 WORKING TEMP. 150BC
E C 120 130
D 90 90 3 WORKING PRES. 10kg/cm2
A
E 21.8 25
B
LN -9 30
C
4 CONNECTING 2: 3/4" JIS 10K
3: 1" JIS 10K

TYPE: LN-9 49
PART LN-941 LN-942
DIMENSIONS
SIZE 1 BODY MATERIAL PP PVDF
CODE 3/4" 1"
D
A, B ACCORDING TO JIS 10K 2 WORKING TEMP. 80BC 120BC

C 172 187 3 WORKING PRES. 5kg/cm


2

A
B D 18 23
C LN 9 49
4 CONNECTING 2: 3/4" JIS 10K
3: 1" JIS 10K

High Temp. Control Valve

TYPE: LN-950 TYPE: LN-960


PART LN-950 LN-960
1 Body Material SUS316 SUS316
2 Working Temp. 350BC 350BC
2 2
3 Working Pres. 25kg/cm 25kg/cm

4 Connecting LN -9 50 LN -9 60
2: 3/4"PT 2: DN15 PN16
3: 1"PT 3: DN20 PN16

11
OPTIONS

As shown below the optional devices can be attached to a By- B. Level Transducer (see page 15, 16)
Pass Level Indicator to monitor and control level of the liquid. 1) 3 wires Standard Type : BPB-3910
2) 2 wires Standard Type : BPB-3920
A. Magnetic Switch (see page 14) 3) 3 wires Explosion-proof Type : BPB-3930
1) Economy Type : BPB-1200 series 4) 2 wires Explosion-proof Type : BPB-3940
2) Standard Type : BPB-1250 series 5) 2 wires Reversible Type : BPB-3950
3) Explosion-proof Type : BPB-1300 series
4) Adjustable Type : BPB-1400 series C. Ruler (see page 13)
1) Stainless steel in cm : BPA-2110
2) Stainless steel in inch : BPA-2120
3) Plastic in cm : BPA-2130
4) Plastic in inch : BPA-2140

1/2"PT plug
A.
Top end Magnetic Switch
Connecting
Flange

16

15 BPB-1220
14 (Economy Type)
13
B. 12
Level Transducer
11

10

9
8

7
Chamber
6

5 BPB-1250
4 (Standard Type)
3

C. BPB-1300
Ruler (Explosion-Proof Type)

Flag Indicator BPB-1400


(Adjustable Type)
Bottom end

12
RULER

TYPE: BPA-2110 (unit: cm) 2M 10ft

TYPE: BPA-2120 (unit: inch)


1. Dimension : 35(W)x1.5(t)xL
L L
2. Material : SUS 304 10 4

3. Color : Black word


5 2
4. Operate Temp. : -20~400BC
0 0
5. Length : 5.8M (228")
35 35

BPA-2110 BPA-2120

TYPE: BPA-2130 (unit: cm) 2M 20ft

TYPE: BPA-2140 (unit: inch)


1. Dimension : 26(W)x3(t)xL
L L
2. Material : Plastic 10 4
3
3. Color : Red word 2
5
4. Operate Temp. : -20~80BC 1

0 0
5. Length : 5.8M (228")
26 26

* Custom-made scale is available. BPA-2130 BPA-2140

13
MAGNETIC SWITCH

TYPE: BPB-1220 / 1230 [ Economy type ] 28


23 25
1. Contact Element : Reed Switch 18 21
2. Switch Form : BPB-1220, 1AB Hold type
BPB-1230, 1AB Normal type
3. Contact Capacity : 1A /30W / 200VDC
4. Housing Material : Aluminum 90 Contact Color :
Black COM
5. Operation Temp. : -20~200 BC 52
38 Brown NC
6. Protection : IP67 Blue NO
7. Cable Length : 1M (Silicon Cable) Yellow/Green GND

TYPE: BPB-1250 / 1260 [ Standard type ]


84
1. Contact Element : Reed switch
2. Switch Form : BPB-1250, 1AB Hold type
BPB-1260, 1AB Normal type
Contact Color :
3. Contact Capacity : 1A / 30W / 200VDC 88 Red COM,
4. Housing Material : Aluminum While NO
90 (BPB-1400/ 1410 / 1450)
5. Operation Temp. : -20~150BC (max. 250BC )
Black COM,
6. Protection : IP65 Red NC
White NO (BPB-1420 / 1430)
1/2"PF

TYPE: BPB-1300 / 1310 [ Explosion-Proof type ]


1. Contact Element : Reed switch 105
2. Switch Form : BPB-1300, 1AB Hold type 20

BPB-1310, 1AB Normal type


Contact Color :
3. Contact Capacity : 1A / 30W / 200VDC
80 Red COM,
4. Housing Material : Aluminum While NO
5. Operation Temp. : -20~85BC (max. 250BC ) 90 (BPB-1400/ 1410 / 1450)
Black COM
6. Protection : EEx d IIC T6
Red NC
White NO (BPB-1420 / 1430)
1/2"NPT
28

TYPE: BPB-1499 [ Adjustable type ]


1. Contact Element : Reed Switch
2. Switch Form : BPB-1400, 1A Hold t ype
BPB-1410, 1A Normal t ype
BPB-1420, 1AB Hold type 20

BPB-1430, 1AB Normal type


f13
BPB-1450, 1A Hold t ype (LED display) Contact Color :
Red COM,
3. Contact Capacity : 1A / 30W / 200VDC
While NO
4. Housing Material : PP 43 (BPB-1400/ 1410 / 1450)
15 10
5. Operation Temp. : -20~140BC Black COM
Red NC
6. Protection : IP67
White NO (BPB-1420 / 1430)
7. Cable Length : 2M (PVC Cable)

14
LEVEL TRANSDUCER

TYPE: BPB-3910 55 30 78 LEVEL SENSOR


EXC IN COM
1. Housing material : PC(IP65) 75(W)x80(H)x55(D) 83 83
2. Tube : f12.7mm / f17.2 (length over 3M)
SUS 304 or SUS 316
3. Accuracy : A6.35mm
PG16

L=0.15~3M
4. Output : approx. 0~1MW three-wire
5. Power : 2.5~36VDC
6. Measuring Range : 0.15~3M / 3~5.8M (f17.2)
7. Ambient Temp. : -10~85BC

f12.7

METER
13~36VDC
55 30 78
TYPE: BPB-3920 / BPB-3950
83 83
1. Housing material : PC(IP65) 75(W)x80(H)x55(D) PCM-1531 24V/DC
TRANSMITTER O/P
2. Tube : f12.7mm /f17.2 (length over 3M)
EXC IN COM
SUS 304 or SUS 316
3. Accuracy : A6.35mm PG16 L=0.15~3M
4. Output : 4~20mA two-wire
5. Power : 13~36VDC
6. Measuring Range : 0.15~3M / 3~5.8M (f17.2)
7. Ambient Temp. : -10~85BC

f12.7 LEVEL SENSOR

Terminal Arrangement

BPB-3910 BPB-3950 BPB-3920

EXC IN COM

TRANSMITTER
83
83

83

PCM-1532
(see page 17)

ZERO SPAN

EXC IN COM +24V O/P

78 78 78

15
TRANSMITTER

TYPE: PCM-1531
1. Power : 13~36VDC 5. Output Resistance : (Vs-13V) / 20mA
2. Input : Level sensor / three-wire 6. Accuracy : K0.1%
3. Input Resistance : 1K~1M W 7. Operation Temp. : -10~80BC
4. Output Current : 4~20mA / two-wire 8. Protection : Ex ia T6

Terminal Arrangement Wiring Configuration


LEVEL
TRANSDUCER

34
EXC IN COM

ZERO SPAN
ZERO SPAN

+24VDC O/P
45.5

POWER SUPPLY
13~36VDC

4~20mA
TYPE: PCM-1532 METER

1. Supply Voltage : 13~36VDC 5. Adjustable Range : 30%


2. Input Signal : 0~1MW 6. Accuracy : A0.1%
3. Phasing Output : 4~20mA 7. Output Resistance : (Vs-13V) / 20mA
4. Inverse Phase Output : 20~4mA 8. Operating Temp. : -10~80BC

Wiring Configuration

PHASING OUTPUT INVERSE PHASE OUTPUT


65

full

full

70
ZERO SPAN ZERO SPAN
empty

empty
COM

COM
EXC
EXC

Power supply Power supply


IN
IN

13~36VDC 13~36VDC

4~20mA 4~20mA
METER METER

17
LEVEL TRANSDUCER WIRING DIAGRAMS

Level transducer (resistance output) connected with Level transducer (4~20mA output) connected with
analog meter for level monitoring. 4~20mA analog meter for level monitoring.

POWER
POWER
SUPPLY
SUPPLY
DC +10V 0V
DC +24V 0V

EXC
Ampere Meter
4~20mA
Volt Meter
0~10V
IN
+24V

COM

Level transducer (4~20mA output) connected with Level transducer (resistance output) connected with
digital meter (PM-Series) for level control. digital meter (PM-Series) for level control.

PM Series PM Series
Panel Meter Panel Meter
SP SP
6 6
5 5
4 4
3 3
2 2
1 1

% %

FINE AUTOMATION FINE AUTOMATION

4~20mA Signal
4 Relay Output 4 Relay Output
Control Output: Resistance Signal Control Output:
Hi-Low setting (SPDT32) Hi-Low setting (SPDT32)
HH, Hi, Lo, LL setting (SPDT34) HH, Hi, Lo, LL setting (SPDT34)

PM Series PM Series
Panel Meter Panel Meter
G 1 19 Signal
1 19
2 20 2 20
3 21 G 3 21
4 22 4 22
F 5 23
F 5 23
6 24 6 24
7 7
8 8

9 25 9 25
10 26 10 26
11 27 11 27
12 28 12 28
13 29 13 29
14 30 14 30
15 31 15 31
16 32 16 32
17 33 17 33
18 34 18 34
35 35
36 36

18
TYPICAL ASSEMBLE

1. Represents a By-pass Level indi- 2. Represents a By-pass Level In- 3. Represents a By-pass Level Indi-
cator with the standard magnetic dicator with explosion-proof mag- cator with adjustable magnetic
switches (Aluminum Alloy) and liq- netic switches. It is applicable switches and SUS304 ruler. It can
uid level transmitter. It is suitable for explosive & hazardous envi- be assembled with upward
for outdoor or moist environment ronments for its housing protec- /downward movable multiple mag-
for its housing protection IP65. tion EEx d IIC T6. netic switches on a riding rod.

1M

90

80

70

60

50

40

30

20

10

fig. 1 fig. 2 fig. 3

19
IMPORTANCE FOR INSTALLATION

1. Because the magnetic switch is a sensitive component, any


extreme shock to the switch will cause a malfunction. Position Orientation Of
2. Make sure there is no external magnetic field or source
Magnetic Switches
within 10 centimeters of the switch to avoid magnetic inter-
ference. Flag display
3. Make sure the wire of the magnetic switch is pointing down.
4. Do not contact any high temperature material with unit's 60
60
cables while wiring.
5. When using magnetic switch to control inductive or capaci-
tive load, a RC protective circuit should be used to ensure
long life of the switch contact.
Magnetic switch
6. The magnetic switch (BPB-1299 & 9BPB-1399) is to be
placed on a chamber, then fasten the magnetic switch to
the chamber with a hose clamp. (see fig.1A and page 19 -
fig.1, fig.2) positioning orientation of magnetic switches as
fig.2A.
7. The magnetic switch must be located near the flag display
and the surface of it is as close to the outer chamber wall
fig. 2A
as possible.
8. Before actuating, be sure all wiring is done correctly.
9. The magnetic switch (BPB-14 series) is to be placed on a
riding rod, then fastened the riding rod to the chamber with
two hose clamps. (see page 19 - fig.3)
10. The install direction of mounting holes see fig.3A

fig. 1A

fig. 3A

20
ORDER INFORMATION

Top End Type


Flat top Dual flange Flat top
A Cap B +Plug C +Plug D +Top mounting flange

Dual flange Flat top Dual flange Dual flange


E +Top mounting flange F +Control valve G +Control valve N +Angle pipe

Connection
Screw Screw Control
1 Flange 2 (bolt type) 3 (nut type) 4 Slip pipe 5 N/A 7 value 8 Jacket

Bottom End Type


Dual flange Dual flange Dual flange
H Dual flange+Plug I +Top mounting flange J +Angel pipe+Plug K +Control valve

Dual flange Dual flange


L +Angle pipe M +Top mounting pipe

21
HOW TO MAKE YOUR ORDER

BP A 1 1 A1H - 1 J 3
Float type (see page 8, 9)
1 : BPB-2 500 (PVDF) C: BPB-2 580 (SUS316)
2 : BPB-2 510 (PP) D : BPB-26 00 (SUS316)
3: BPB-254 0 (SUS316) E : BPB-262 0 (TITANIUM)
A: BPB-256 0 (SUS316) G : BPB-263 0 (TITANIUM)

Chamber
1: SUS304 -- 140BC 6: PP -- 80BC
2: SUS304 -- 400BC (350BC) 7: PVDF -- 120BC
3: SUS316 -- 140BC 8: SUS304 -- 200BC
4: SUS316 -- 400BC (350BC) 9: SUS316 -- 200BC

Flag Display (see page 10)


1: BPB - 0700
2: BPB - 0710
3: BPB - 0720
4: BPB - 0730

End / Connection type (see page 21)


Top end Type Connection Bottom end Type
A : Cap 1: Flange H : Dual flange+Plug
B : Flat top+Plug 2: Screw (bolt type) I : Dual flange
C: Dual flange+Plug 3: Screw (nut type) +Top mounting flange
D: Flat top 4: Slip pipe J : Dual flange+angel pipe
+Top mounting flange 5: N/A +Plug
E : Dual flange 7: Control value K : Dual flange+control valve
+Top mounting flange 8: Jacket L : Dual flange+angle pipe
F : Fla t top+Control valve M: Dual flange
G: Dual flange+Control valve +Top mounting pipe
N: Dual flange+angle pipe

Operating Pressure range


1: -1~ 10kg/cm2
2: -1~ 25kg/cm2
3: -1~ 50kg/cm2
4: -1~100kg/cm2

Magnetic Switch (see page 14) Quantity


A: BPB -1220 G: BPB -1400 1~ 4
B: BPB -1230 H : BPB -1410
C: BPB -1250 I : BPB -1420
D: BPB -1260 J : BPB -1430
E : BPB -1300 K : BPB -1450
F : BPB -1310

22

You might also like