3. CONDUIT AND WIRING RUNS ARE SCHEMATIC ACTUAL RUNS LIGHTING OUTLET PANEL BOX EXTERIOR INTERIOR 4" THK. CHB WALL
SHALL BE 2200mm
DETERMINED DURING CONSTRUCTION. CONVENIENCE OUTLET SERVICE ENTRANCE
4. CONDUCTORS SHALL BE IN PVC PIPE (MOLDFLEX FLEXIBLE) POWER LINE M KILOWATT HOUR METER
CONCEALED TELEPHONE MODULAR
OUTLET @ INTERIOR
INSIDE CEILING OR EMBEDDED IN CONCRETES FLOORS, SWITCH LINE ACU AIRCONTIONING OUTLET
COLUMNS, AND WALLS
EXCEPTS SERVICE CONDUCTORS SHALL BE IN RIGID STEEL
CONDUIT. 300mm
5. PROVIDE JUNCTION BOX WHENEVER DEEMED NECESSARY. FIN. GROUND FLR. LINE
6. POWER SUPPLY SHALL BE SINGLE PHASE 230 VOLTS, 60 HZ, 1D, 2W.
MAIN BREAKER: FIN. GRADE LINE
10mmØ REBAR:
FOR SERVICE DROP
5 6 ATTACHMENT
2
USE: 2-14MM THHN WIRE 7 8 5-12mmØ REBARS. E.S
B.W.
800mm
2
1-8.0MM THHN WIRE 300X200mm (BASE) R.C. ELEC. PRIVATE
POLE. (R.C. COL. LOC. WHERE
APPLICABLE)
250mm TO 300mm
TYPICAL DETAIL OF
ELECTRIC PRIVATE POLE
SCALE: NTS
CLIENT'S GOVERNMENT
CONSTRUCTION
APPROVAL APPROVAL
E-3