1. ALL ELECTRICAL INSTALLATION WORKS HEREIN SHALL BE DONE IN ACCORDANCE WITH THESE PLANS AND SERVICE ENTRANCE POWER PANEL BOARD
SPECIFICATIONS, THE APPLICABLE PROVISIONS OF THE LATEST EDITION OF THE P.E.C. THE RULES AND
REGULATIONS OF THE LOCAL ENFORCING AUTHORITY AND THE REQUIREMENTS OF THE LOCAL POWER
COMPANIES,THE ELECTRICAL WORKS SHALL BE UNDER THE IMMEDIATE SUPERVISION OF A DULY LICENSED CIRCUIT BREAKER
REGISTERED ELECTRICAL ENGINEER. MAIN DISTRIBUTION PANEL BOARD
2. THE ELECTRICAL SERVICE VOLTAGE SHALL BE THREE-PHASE, 4-WIRE + G,
400/230 VOLTS, 60 HZ, 1POLE LINE TO NEUTRAL.
CIRCUIT HOMERUN
KILOWATT-HOUR METER
3. THE ELECTRICAL WIRING INSTALLATION SHALL BE DONE IN IMC CONDUIT. FLEXIBLE CONDUIT SHALL BE USED
WHERE REQUIRED MINIMUM SIZE FOR ALL CONDUITS SHALL BE 20 mm DIA. ELECTRICAL TRADE SIZE, CONDUITS
GROUND LINE
SHALL BE INTERMEDIATE METAL CONDUITS ( IMC) AND SHALL BE USED IN MAIN SERVICE ENTRANCE.
4. ALL WIRES SHALL BE COPPER AND THERMOPLASTIC INSULATED TYPE "THHN" OR"THW" UNLESS OTHERWISE PINLIGHT Sa ONE GANG SWITCH
INDICATED, THE MINIMUM SIZE FOR POWER AND LIGHTING SHALL BE 3.5 SQ.MM THE CONTROL WIRES SHALL BE
AS INDICATED OR SPECIFIED ELSEWHERE ON PLANS.
CONVENIENCE OUTLET 2Sab TWO GANG SWITCH
5. THE CONTRACTOR SHALL VERIFY AND ORIENT THE ACTUAL LOCATION OF SERVICE ENTRANCE FOR PLATE COVER
CONNECTION TO THE POWER SUPPLY. MODERN PLATE,
ELEC. WATER HEATER COLOR BY ARCHITECT
6. ALL SERVICE ENTRANCE EQUIPMENT, SWITCHES, PANEL BOARDS, LIGHTING FIXTURES AND ALL
3Sabc THREE GANG SWITCH
NON-CURRENT CARRYING METAL PARTS SHALL BE PROPERLY GROUNDED IN ACCORDANCE WITH THE CONV. OUTLET, RATED UTILITY BOX, GA. 18
PHILIPPINE ELECTRICAL CODE. REF. OUTLET 20A, 250V, PARALLEL DEEP TYPE
SLOT WITH GROUND
7. ANY DISCREPANCY IN LOCATION AND RATINGS OF EQUIPMENT AND APPARATUS SHALL BE VERIFIED WITH THE
OWNER OR ANY OF HIS REPRESENTATIVES AND CHANGES SHALL BE MADE ACCORDINGLY.
LOCKNUT W/
0.30 MTS.
0.30 MTS.
8. ALL MATERIALS TO BE USED AND THE EQUIPMENT TO BE INSTALLED SHALL BE BRAND NEW A ND MUST BE BUSHING
OF THE APPROVED TYPE FOR THE PARTICULAR LOCATION AND PROPOSED INTENDED.
1.40 MTS.
(BY NATIONAL)
1.40 MTS.
PLATE COVER
MODERN PLATE,
COLOR BY ARCHITECT
NOTE: FIN. FLR. LINE
FIN. FLR. LINE
These drawings are the ELECTRICAL ENGINEER: PROJECT TITLE: OWNER: SHEET CONTENT: REVISION: SHEET NO.
intellectual property of the said
contractor and as such must not DATE:
be recopied or reproduced in
whole or in part without the ELECTRICAL ENGINEER: PURPOSE 1
written or direct permisson from
the owner. Violation of the law
under the Republic Act ( R.A
PRC. REG. No.
PTR. No.
LOCATION: LOCATION:
E
9266.Art.111,Sec-20#4 ) is
UNLAWFUL punishable by law
DATE
ISSUED AT
4
LAUNDRY
AREA
g
Sh h
Sg
f e d
KITCHEN BEDROOM 1 BEDROOM 2
Se Sd
2Sef Sc CKT.
a 2
f
Sf c c
e
DINING
AREA
d d g g 2Sab
OPEN
Sg b
BELOW a
g
MASTERS
d BEDROOM
LIVING
AREA g g
2Sab d 2Sdc d a a
GARAGE
b b BALCONY
c PORCH c
a a a a
CKT.
1
These drawings are the ELECTRICAL ENGINEER: PROJECT TITLE: OWNER: SHEET CONTENT: REVISION: SHEET NO.
intellectual property of the said
contractor and as such must not DATE:
be recopied or reproduced in
whole or in part without the ELECTRICAL ENGINEER: PURPOSE 2
written or direct permisson from
the owner. Violation of the law
under the Republic Act ( R.A
PRC. REG. No.
PTR. No.
LOCATION: LOCATION:
E
9266.Art.111,Sec-20#4 ) is
UNLAWFUL punishable by law
DATE
ISSUED AT
4
LAUNDRY
AREA
WASHING
CKT.
11
CKT. CKT.
6 REF
5
EWH
CKT. CKT.
8 9
ACU
ACU
BEDROOM 1 BEDROOM 2
KITCHEN
DINING
AREA
OPEN
CKT. BELOW
4
MASTERS
BEDROOM CKT.
LIVING ACU 10
AREA
CKT.
3
GARAGE
BALCONY
CKT.
7
PORCH
W.PUMP
8-OUTLET 7-OUTLET
These drawings are the ELECTRICAL ENGINEER: PROJECT TITLE: OWNER: SHEET CONTENT: REVISION: SHEET NO.
intellectual property of the said
contractor and as such must not DATE:
be recopied or reproduced in
whole or in part without the ELECTRICAL ENGINEER: PURPOSE 3
written or direct permisson from
the owner. Violation of the law
under the Republic Act ( R.A
PRC. REG. No.
PTR. No.
LOCATION: LOCATION:
E
9266.Art.111,Sec-20#4 ) is
UNLAWFUL punishable by law
DATE
ISSUED AT
4
OVERHEAD SERVICE DROP
USE 38mm2 Aluminum Wire
SERVICE
ENTRANCE
M 2-30mm2 THHN in 63mm uPVC CONDUIT
TERMINAL BOX
M METER CENTER
5 6
7 8
4-Ø12 LONG'L. BARS
ELECTRICITY PROVIDER
800 NGL
11 12
200
200
800
GROUND ROD
FOOTING LINE
PLAN 3 RISER DIAGRAM
2 PANEL BOARD DIAGRAM E 4 NOT DRAWN TO SCALE
NGL
E 4 NOT DRAWN TO SCALE
VERIFY
PANEL BOARD 1
BOT. OF FOOTING
CONDUIT
CIRCUIT NO. OF NO. OF DIAMETER
4-Ø16 BOT. BARS EQUALLY LOAD DESCRIPTION VOLTS WATTS AMPERE BREAKER WIRE SIZE
800 NO. OUTLET POLE (mm)
SPACED BOTH WAYS
1. LIGHTNING LOAD 17 230 1700 7.39 2P 20AT 2- 3.5mm² THHN & 1- 2.0mm² Ø20mm PVC
WELL COMPACTED BASE 50mm THICK LEAN
CONCRETE (SEE NOTE 1)
2. LIGHTNING LOAD 15 230 1500 6.52 2P 20AT 2- 3.5mm² THHN & 1- 2.0mm² Ø20mm PVC
SECTION
NOTE:
3. CONVENIENCE OUTLET 8 230 1440 6.26 2P 20AT 2- 3.5mm² THHN & 1- 2.0mm² Ø20mm PVC
1.A WELL COMPACTED AND PROPERLY LEVELED GRAVEL BEDDING 4. CONVENIENCE OUTLET 7 230 1260 5.47 2P 20AT 2- 3.5mm² THHN & 1- 2.0mm² Ø20mm PVC
(100MM THICK) CAN BE USED IN LIEU OF THE LEAN CONCRETE. 5. REFRIGERATOR 1 230 1100 4.78 2P 30AT 2- 3.5mm² THHN & 1- 2.0mm² Ø20mm PVC
2. VERIFY THE CORRECTNESS OF THIS STANDARD DRAWING TO THE 6. ELEC. WATER HEATER 1 230 1100 4.78 2P 30AT 2- 3.5mm² THHN & 1- 2.0mm² Ø20mm PVC
STANDARD REQUIREMENTS OF THE LOCAL ELECTRICITY PROVIDER
PRIOR TO CONSTRUCTION OF THE POLE STRUCTURE. ANY 7. WATER PUMP 1 230 1840 8.0 2P 30AT 2- 3.5mm² THHN & 1- 2.0mm² Ø20mm PVC
DISCREPANCY SHALL BE NOTIFIED TO THE ENGINEER FOR
RESOLUTION AND/OR REVISIONS. 8. 1 HP ACU 1 230 1100 4.78 2P 20AT 2- 3.5mm² THHN & 1- 2.0mm² Ø20mm PVC
9. 1 HP ACU 1 230 1100 4.78 2P 30AT 2- 3.5mm² THHN & 1- 2.0mm² Ø20mm PVC
10. 1.5 HP ACU 1 230 1840 8.0 2P 30AT 2- 3.5mm² THHN & 1- 2.0mm² Ø20mm PVC
1 SERVICE ENTRANCE/METER POLE DET. 11. WASHING MACHINE 1 230 1100 4.78 2P 30AT 2- 3.5mm² THHN & 1- 2.0mm² Ø20mm PVC
These drawings are the ELECTRICAL ENGINEER: PROJECT TITLE: OWNER: SHEET CONTENT: REVISION: SHEET NO.
intellectual property of the said
contractor and as such must not DATE:
be recopied or reproduced in
whole or in part without the ELECTRICAL ENGINEER: PURPOSE 4
written or direct permisson from
the owner. Violation of the law
under the Republic Act ( R.A
PRC. REG. No.
PTR. No.
LOCATION: LOCATION:
E
9266.Art.111,Sec-20#4 ) is
UNLAWFUL punishable by law
DATE
ISSUED AT
4