LOAD COMPUTATION & SCHEDULE

ELECTRICAL GENERAL NOTES PB-1 PANEL FLUSH MOUNTED, NEMA 1 ENCLOSURE WITH GROUND TERMINAL
ALL ELECTRICAL WORKS HEREIN SHALL COMPLY WITH THE PROVISIONS OF THE LATEST EDITION OF 2 - 14mm 2THHN
THE PHILIPPINE ELECTRICAL CODE (PEC) WITH THE RULES & REGULATIONS OF THE NATIONAL & 1 - 5.5mm2 THHN
LOCAL AUTHORITIES CONCERNED IN THE ENFORCEMENT OF ELECTRICAL LAWS AND ORDINANCES OF 25mmØ RSC
THE LOCAL UTILITY COMPANIES CONCERNED;
ALL MATERIALS TO BE USED SHALL BE NEW AND OF THE APPROVED TYPE FOR BOTH LOCATION
AND PURPOSES INTENDED;
MAIN
ALL EQUIPMENTS SUCH AS DISTRIBUTION PANEL, LIGHTING AND POWER PANEL, ETC. SHALL BE 60AT,2P
PROPERLY GROUNDED IN ACCORDANCE WITH THE REQUIREMENTS OF THE PHILIPPINE ELECTRICAL
MOUNTING HEIGHTS SHALL BE AS FOLLOWS (APPROVED BY THE ARCHITECT): 1P/20AT 1P/20AT
A. LIGHT CONTROL SWITCHES - 1.40M ABOVE FLR. FIN. AT THE CENTER; LIGHTING 1 2 LIGHTING
B. TELEPHONE, INTERCOM AND CONVENIENCE OUTLETS - 0.30M ABOVE FLR.FIN AT THE CENTER 1P/20AT 1P/30AT
C. DESK TOP, COUNTERTOP CONV. OUTLET - 0.30M ABOVE WORKING COUNTER AT THE CENTER
D. PANEL BOARDS, CABINETS AND DISCONNECT SWITCHES AS REQUIRED; LIGHTING 3 4 C.O.
1P/30AT 1P/30AT
FLOURESCENT-TYPE REQUIREMENT AS FOLLOWS: 6 C.O.
A. ALL FLOURESCENT FIXTURES SHOULD HAVE A METAL CASING;
C.O. 5
B. PROVIDE MICA TUBING INSULATION OF NOT MORE THAN 12" LENGTH ON ALL FLOURESCENT
1P/30AT 1P/30AT
AND PINLIGHT TERMINATION FOR PROPER CONNECTION; REF 7 8 RANGE
C. ALL FLOURESCENT AND PINLIGHT BALLAST SHALL BE OF HIGH POWER FACTOR AND ENCLOSED 1P/30AT 1P/30AT
IN A METALLIC BOX;
D. ALL ELECTRICAL WIRINGS AND INSTALLATIONS FROM PANEL TO FIXTURES SHALL HEVE AN EMT ACU 9 10 ACU
CONDUIT OR RSC PIPES; 1P/30AT 1P/30AT
E. OPEN WIRING AND FLAT CHORD WIRES ARE BOT ALLOWED;
SPARE 9 10 SPARE
OTHER REQUIREMENTS:
NEUTRAL BUS BAR G.L.
A. PROVIDE AUTOMATIC CIRCUIT BREAKER FOR ELECTRICAL CONTROL;
B. BX WIRES OR FLEXIBLE CONDUIT ARE NOT ALLOWED;
C. USE METAL COVER FOR ALL JUNCTION AND PULL BOXES;
D. PROVISION FOR PILOT LIGHTS;
E. ELEC. LOAD SHALL NOT EXCEED THE CAPACITY OF THE MAIN CIRCUIT BREAKER AND THE GROUND WIRE
FEEDER WIRE DESIGNATED FOR THE AREA;
1 SINGLE LINE DIAGRAM
SPECIFICATIONS OF PANELBOARD AND MDP: E 1 Scale NTS
1. SEE LOAD SCHEDULE AND COMPUTATIONS FOR MORE DETAIL.
2. ALL PANELS WITH GROUNDING BUS, ALL GROUND BUS TERMINAL SHALL BE LUGS TYPE AND
SHALL BE THE NUMBER OF BRANCH CIRCUITS IS THE NUMBER OF TERMINAL LUGS.
3. MATERIAL NOMINAL THICKNESS COVER -GAUGE 14 AND ONLY ONE TYPE OF CIRCUIT BREAKER MAIN FEEDER LINE
4. ENCLOSURE TYPE INDOOR USE, WALL MOUNTED AND ALL PANEL SHALL BE BOLTED TYPE, G.I.
/B.I. SHEET AND POWDER COAT PAINT FINISH BEIGE COLOR.
5. ALL CIRCUIT BREAKER SHALL BE MITSUBISHI BRAND/SQUARE D,SIEMENS,ABB, BOLT-ON TYPE.
BEING USE.
6. CVMK CONVENTIONAL METERING OR UL LISTED SHALL BE INSTALLED AT MAIN DISTRIBUTION PANEL. M
7. ALL MAIN CIRCUIT BREAKERS,INDIVIDUAL BRANCH CIRCUITS TERMINAL SHALL HAVE FULLY
SILVER TIN COATED AND HAVE A BAKELITE INSULATOR.
8. ACCREDITED PANELBOARD FABRICATOR SHALL BE EDISON ELECTRIC , LJ INDUSTRIAL 2 - 14mm² THHN
FABRICATION, POWER BOX FABRICATION AND ALL BETTER BOX MATSUDA & ALLIED CONTROL. 1 - 5.5mm² THHN
9. ALL HOLE OF BUSBAR SHALL BE SAME AS THE SIZE OF BOLT. BOLT SHALL BE TIGHT THE 60 AT 25mmØ RSC
CONNECTION OF BUSBAR TO BUSBAR AND BUSBAR TO BREAKER. 60AT,2P
10. ALL BUSBAR SHALL HAVE HEAT SHRINKABLE, L1= RED, L2= YELLOW.
11. PROVIDE MARKING TORQUE FOR THE TERMINATION OF BUSBAR AND BREAKER. PB
12. SUBMIT SHOP DRAWING FOR EVALUATION AND APPROVAL OF AN ELECTRICAL CONSULTANT.
2 ELECTRICAL RISER DIAGRAM
E 1 Scale NTS
Drawings and Specifications duly signed, stamped
or sealed, as instruments of service are the
intellectual properties and documents of the
ELECTRICAL GENERAL NOTES
ENGINEER / ARCHITECT , whether SPECIFICATION OF PANEL BOARD AND MDP E-1
the object for which they are made is executed or
PROPOSED SINGLE STOREY RESIDENTIAL BLDG SINGLE LINE DIAGRAM
MRS. ALICE EBAL
not. It shall be unlawful for any person, without the
PROFESSIONAL ELECTRICAL ENGINEER consent of the ENGINEER / ARCHITECT ELECTRICAL RISER DIAGRAM
or author of said documents, to duplicate or to
make copies of said documents for use in the
repetition of and for other projects or buildings,
whether executed partly or in whole.
BRGY. MALABON, CANDELARIA, ZAMBALES 9 / 14