5. No revision in the design shall be done without written consent of the signing PANEL BOX fan line
professional Electrical Engineer, only revision done without such approval shall CIRCUIT HOMERUN power line
cause responsibility of the pee to cease as a whole. SERVICE ENTRANCE circuit number
6. Mounting heights (from horizontal centerline) shall be. CIRCUITRY RUN THRU CEILING switch line
Panel Board = 1370mm (4'-0") CIRCUITRY RUN THRU WALL ceiling fan
Switches = 1370mm (4'-0") CIRCUIT BREAKER SF switch for fan
Outlet = 460mm (18")
KWHM = 1520mm (5'-0")
7. All materials shall be new and approved type circuit breakers General Electric "GE".
8. PVC and uPVC shall be moldex or equivalent approved quality.
9. Panel board shall be approved type, with copper busbar.
SCHEDULE OF LOADS
PB G/F
LOCATION: GROUND FLOOR
CKT. No. of
NO. DESCRIPTION OUTLET WATTS VOLTS AMPS CB SIZE OF WIRE & CONDUIT
PANEL BOX
1 LIGHTING OUTLET 11 1100 230 4.78 20AT 3.5mm² THHN +2.0TW gnd, 20mmØ PVC
2 LIGHTING OUTLET 9 900 3.91 20AT 3.5mm² THHN +2.0TW gnd, 20mmØ PVC
3 LIGHTING OUTLET 10 1000 4.35 20AT 3.5mm² THHN +2.0TW gnd, 20mmØ PVC
4 LIGHTING OUTLET 10 1000 4.35 20AT 3.5mm² THHN +2.0TW gnd, 20mmØ PVC
5
6 LIGHTING OUTLET 7 700 3.04 20AT 3.5mm² THHN +2.0TW gnd, 20mmØ PVC
7 CONVENIENCE OUTLET 5 900 3.91 20AT
8 CONVENIENCE OUTLET 4 720 3.13 20AT
9 SPARE 1 2000 20AT
10 SPARE 1 2000
TOTAL 11820 230 33.99
PROJECT TITLE: DRAFTED BY: CHECKED BY: RECOMMENDING APPROVAL: APPROVED BY: SHEET CONTENT: SHEET NO.:
1'
1 co
co
co
7
co PB
co
co
co
3 co
8
3'
POWER LAYOUT
SCALE 1:75
PROJECT TITLE: DRAFTED BY: CHECKED BY: RECOMMENDING APPROVAL: APPROVED BY: SHEET CONTENT: SHEET NO.:
j j j
1' h Sf
f e
Sh g
Sg j
1 i Se
Shij
h
4
i
Sabc
Sci PB-GF a b c
d a
Sgf
c
Sd 1 d
g f
e
Sabj
2 j
h c LAV
e e
g f
d
b d a
g b Sed Sgf
a b c
2
f a Sabc
Sfgh Sabc Shij
3 b
h 3 i
j
3'
j j j
6
LIGHTING LAYOUT
SCALE 1:75
PROJECT TITLE: DRAFTED BY: CHECKED BY: RECOMMENDING APPROVAL: APPROVED BY: SHEET CONTENT: SHEET NO.:
CO DIGESTIVE CHAMBER
A MANHOLE MANHOLE MANHOLE
A 0.50 1.50 2.00 1.50 2.00 1.50 DIGESTIVE CHAMBER
CHAMBER CHAMBER
LEACHING LEACHING
INLET
CO CO
OUTLET
B
1.50 0.75 0.75 1.50 0.75 0.75 1.50
USE 4''CHB With plastered on single face
3.00 3.00
PROJECT TITLE: DRAFTED BY: CHECKED BY: RECOMMENDING APPROVAL: APPROVED BY: SHEET CONTENT: SHEET NO.:
1'
SH SH
1 F
SEPTIC
TANK
1/2"Ø CWP
F
WC
1/2"Ø CWP SH
3/4"Ø CWP DL
2
SH F
3/4"Ø CWP DL
SH
WC
3
3'
3/4"Ø CWP DL
To Water Storage Tank
WATER LAYOUT
SCALE 1:75
PROJECT TITLE: DRAFTED BY: CHECKED BY: RECOMMENDING APPROVAL: APPROVED BY: SHEET CONTENT: SHEET NO.:
C.B.
C.B.
1'
C.B.
DS
FD
FD FD
1 LAV
SEPTIC
TANK
6"Ø RCP
6"Ø RCP
LAV
WC
FD
C.B.
DS
FD LAV FD
WC WC
6"Ø RCP
LAV
3
3'
C.B.
DS
PLUMBING LAYOUT
SCALE 1:75
PROJECT TITLE: DRAFTED BY: CHECKED BY: RECOMMENDING APPROVAL: APPROVED BY: SHEET CONTENT: SHEET NO.:
0.60 0.80
0.20
SCHEDULE OF FOOTINGS
THK. SIZE (m) BOTTOM BARS DEPTH OF
MARK (mm) REMARKS
WIDTH LENGTH BAR 'S' BAR 'L' EXCAVATION 3 - 10mmØ Longi. Bars
F1 200 1.20 2.40 8 - 12mmØ 16 - 12mmØ 1.20m from NGL COMBINED FOOTING & 10mmØ Lateral Ties
F2 200 1.20 1.20 6 - 12mmØ 6 - 12mmØ 1.20m from NGL ISOLATED FOOTING 0.40
@ 0.30m o.c.
VERIFY FOUNDATION PLAN
WALL FOOTING DETAIL
NOT TO SCALE
0.30
PROJECT TITLE: DRAFTED BY: CHECKED BY: RECOMMENDING APPROVAL: APPROVED BY: SHEET CONTENT: SHEET NO.:
13.00
0.85
RAFTER
1'
1.50 1.50
1 0.80
1.50
0.70
3.50 3.50
1.00
1.00
2 9.70 10.00
1.00
1.00
3.50 3.50
1.50
3
1.20 1.50
3'
C PURLINS
USE:
1. 0.4mm thk. Rib Type Roofing,
Gutter & Flashing.
2. 3 - 50mm x 150mm Good Lumber
for Rafter. 1.20 4.80 1.50 4.35
3. 50mm x 75mm Good Lumber
spaced @ 0.60m o.c. 6.00 5.85 1.15
4. 25mm x 25mm Good Lumber for
Fascia 13.00
6. 3/4" thk. Marine Plywood for Fascia
PROJECT TITLE: DRAFTED BY: CHECKED BY: RECOMMENDING APPROVAL: APPROVED BY: SHEET CONTENT: SHEET NO.:
13.00
ROOFLINE
B2 B2 B2
1'
1.50 B1 B1 B1 B1 1.50
B1 B1 B1 B1 B1
1
3.50 B1 B1 B1 B1 B1 B1 3.50
B1 B1 B1 B1 B1
2 10.00 10.00
3.50 B1 B1 B1 B1 B1 B1 3.50
B1 B1 B1 B1 B1
3
B1 B1 B1 B1
1.50 1.50
3' B2 B2 B2
13.00
PROJECT TITLE: DRAFTED BY: CHECKED BY: RECOMMENDING APPROVAL: APPROVED BY: SHEET CONTENT: SHEET NO.:
13.00
ROOFLINE
1' WF WF WF WF
1.50 Elev. = 0.60m Elev. = 0.60m 1.50
C1/F2 C1/F1 C1/F2
TB TB
1
Use: 10mmØ DRB spaced @
3.50 TB 0.30m o.c. bothways. & 100mm TB TB Elev. = 0.60m TB 3.50
thk. Slab Finished Floor.
Elev. = 0.60m
C1/F2 C1/F1 C1/F2
2 10.00 WF TB TB
10.00
Elev. = 0.60m
3.50 TB TB TB Elev. = 0.60m TB 3.50
3.00 13.00
FOUNDATION PLAN
SCALE: 1:100
PROJECT TITLE: DRAFTED BY: CHECKED BY: RECOMMENDING APPROVAL: APPROVED BY: SHEET CONTENT: SHEET NO.:
13.00
0.85
ROOFLINE
1'
1.40 1.00 FF2 FF2 1.50
1 FF1
0.40 0.80
1.50
FF1 0.70
3.50 FF1 3.50
FF2 2.00
FF1
FF3
2 9.60 10.00
13.00
PROJECT TITLE: DRAFTED BY: CHECKED BY: RECOMMENDING APPROVAL: APPROVED BY: SHEET CONTENT: SHEET NO.:
13.00
0.85
1'
1.50 1.10 1.50
1 0.40 0.80
1.50
0.70
3.50 3.50
1.00
1.00
2 10.00 10.00
1.00
1.00
3.50 3.50
1.50
3
1.50 1.50
3'
USE:
1. 50mm x 50mm Good Lumber
spaced @ 0.60m o.c bothways. 1.20 4.80 1.50 4.35
2. 1/4" thk. Marine Plywood.
3. 4' x 8' Steel Matting 6.00 5.85 1.15
13.00
PROJECT TITLE: DRAFTED BY: CHECKED BY: RECOMMENDING APPROVAL: APPROVED BY: SHEET CONTENT: SHEET NO.:
1.65 Use:
1. 6mm thk. x 50mm x 50mm Angle Bar for Steel Frame.
2. 20mmØ Round Bar for Horizontal & Vertical Supports.
FLOOR LINE
Description : Window Grilles 2 Description : Window Grilles 3 Description : Window Grilles 4 Description : Window Grilles 5 Description : Window Grilles 6 Description : Window Grilles 7
Location : Floor Plan Location : Floor Plan Location : Floor Plan Location : Floor Plan Location : Floor Plan Location : Floor Plan
Required : 2 Sets Required : 1 Set Required : 2 Sets Required : 2 Sets Required : 1 Set Required : 2 Sets
0.95
SG1 SG2 SG3
2.00 5800mm 3100mm 1300mm
WG1
5800mm
1.65 Use:
1. 6mm thk. x 50mm x 50mm Angle Bar for Steel Frame.
2. 20mmØ Round Bar for Horizontal & Vertical Supports.
0.60
FLOOR LINE
Description : Steel Grilles 1 Description : Steel Grilles 2 Description : Steel Grilles 3 Description : Window Grilles 1
Location : Floor Plan Location : Floor Plan Location : Floor Plan Location : Floor Plan
Required : 1 Set Required : 1 Set Required : 1 Set Required : 1 Set
Use:
1. 150mm Rectangular
Tube for Steel Frame.
2. 20mmØ Round Bar Use:
for Horizontal & 1. 50mm x 50mm Angle
D1 D2 D3 D4 SD Vertical Supports.
DG Bar for Steel Frame.
2.15 1500mm
2.15 900mm
2.15 800mm
2.15 2.15 1000mm
3. Heavy Duty Sliding 2.15 900mm
2. 20mmØ Round Bar for
800mm Track & Accessories Horizontal & Vertical
Supports
3. 6mm thk. Steel Plate
FLOOR LINE
SCHEDULE OF DOORS & WINDOWS Description : Double Swing Aluminum Description : Flushed Type Door Description : Flushed Type Door Description : PVC Door with Louver Description : Steel Sliding Door Description : Door Grilles
Glass Door Location : See Floor Plan Location : See Floor Plan Location : See Floor Plan Location : Floor Plan Location : Floor Plan
SCALE: 1:100 Location : See Floor Plan Required : 3 Sets Required : 1 Set Required : 5 Sets Required : 3 Sets Required : 2 Sets
Required : 1 Set
D C B A
TOP OF ROOF 0.40
1.35 WG2
5300mm
WG6
1300mm
WG1
5800mm
5.00 5.00
3.00 3.00
1.65
GFL 6" CHB with Fine 6" CHB with Fine
Plastered Finish Plastered Finish
0.60 NGL 0.40 0.60
0.20
PROJECT TITLE: DRAFTED BY: CHECKED BY: RECOMMENDING APPROVAL: APPROVED BY: SHEET CONTENT: SHEET NO.:
WG2
5300mm
1.35
5.00 SG1 SG3 5.00
3.00 5800mm 1300mm
3.00
1.05
6" CHB with Fine 6" CHB with Fine GFL 0.60
Plastered Finish Plastered Finish
0.60 0.40 NGL 0.60
0.20
1 2 3 3 2 1
0.40
0.20
10.00 10.00
REAR ELEVATION
FRONT ELEVATION SCALE: 1:100
SCALE: 1:100
PROJECT TITLE: DRAFTED BY: CHECKED BY: RECOMMENDING APPROVAL: APPROVED BY: SHEET CONTENT: SHEET NO.:
3.00 13.00
ROOFLINE
WG1 WG6 WG2
5800mm 1300mm 5300mm
1' T&B
1.50 1.10 D4 D4
DOFFING 1.50
800mm
800mm
AREA
UP PERSONNEL
1 RAMP PANTRY
D2
900mm
BARRACK D3
800mm
D2
900mm
0.80
UP PHARMACY
SD
HIGH CONTAGOUS 1.50
1000mm WARD 0.70
D1 D4 WG4
3.50 1500mm
RECORDS
800mm 3100mm 3.50
H
PWD
REGISTRATION A T&B 2.00
L
AREA
2 10.00 D2
900mm
L
W
10.00
PWD A PWD
T&B Y T&B 2.00
SG2 WG3 D4 WG4
3.50 3100mm 3300mm 800mm 3100mm 3.50
LOW D4 SD MEDIUM CONTAGOUS
DONNING 800mm
AREA CONTAGOUS 1000mm
WARD
WARD 1.50
DG SD
3 900mm
WG5
1000mm
WG5
1750mm 1750mm
1.50 DG
900mm
HALLWAY WG7
1200mm
1.50
3' SG1 SG3 WG2
5800mm 1300mm 5300mm
3.00 13.00
FLOOR PLAN
SCALE 1:100
PROJECT TITLE: DRAFTED BY: CHECKED BY: RECOMMENDING APPROVAL: APPROVED BY: SHEET CONTENT: SHEET NO.:
A
1 TABLE OF CONTENTS
DEPARTMENT OF PUBLIC WORKS & HIGHWAYS
OFFICE OF THE BUILDING OFFICIAL
ARE
BAYUGAN CITY
PY TECHNICAL DESCRIPTION
AM
SW 1
63.9 LINE BEARING DISTANCE SHT. NO. DESCRIPTION LAND USED & ZONING
VICINITY MAP
CE
1-2 97.77 m 1
TER
FEN
S 17° 63' E 16
SITE DEVELOPMENT PLAN
PERSPECTIVE
ST
IME
PER
ARY
RIM
GP
2
EXIS
TIN
2-3 S 77° 14' W 64.19 m 16
ARCHITECTURAL DRAWINGS
ENC
E
ST 3
DAR
YP
ERIM
ETE
RF
3-4 N 17° 45' W 90.00 m 16
ARCHITECTURAL DRAWINGS
LINE & GRADE
EXIS
N
ECO
4 EXIS
TIN
G S
TING
EXIS
48.8
4-1 63.91 m ARCHITECTURAL DRAWINGS
EXIS
OF N 70° 17' E 16
PRIM
ION
TING
TING BUILDI
UCT ING 2
8
R
T 5
SEC
ARY
S IL
CON AIL BU
OND
ARCHITECTURAL DRAWINGS
ING
A J
TIELINE FROM BLLM No. 1, PLS-450-0
PER
16
TWO NG 1
ARE - GO TOREY
ARY
ED ON S
POS
IME
-
TWO
PER
TER
- ST
IME
FEN
S
DEV GRAM D
ORE
FE
O ARCHITECTURAL
CE
PR LIHOO 7
NCE
LIVE IVITIES m)
Y JA
STRUCTURAL DRAWINGS
ACT x 17.00 16
10.0
00m OF
IL
(10. ION T
N
UCT
STR LL COU
R 8 STRUCTURAL DRAWINGS
O BA 16
0m
C
P O SED ASKET
PRO ERED B 9
COV
wide 97.77
EXIS
PER
ENT ATE
ND ARY
ECO
GS
10
PRIM
TIN
EXIS STRUCTURAL
Roa
RAN
STRUCTURAL DRAWINGS
46.6
16
ARY
CE
PER
11
6
d
PLUMBING DRAWINGS
IME
REA 16
TER
DA E
GAT
OSE ATION FEN
C E
12
FEN
O P L TER
PR ISO PER
IME
PLUMBING DRAWINGS
FOR ACILITY 0m)
CE
ARY
F .0 TING
SEC
OND
16
x 22
IN
EXIS ADM F
TING
00m EXIS ICE (ST
AF
13
(10. OFF FFICE)
O PLUMBING DRAWINGS
mx
6.00
m
16 SANITARY
5.10
PRO
VISIO
PRO
15 ELECTRICAL DRAWINGS
NO
SWA
PER
16
F PR
T
16
90.0
IMA
Y LI
ELECTRICAL DRAWINGS
RY
MPY
16
NE
48.8
PER
ELECTRICAL
0
IME
TER
8
ARE
FEN
CE
A
EA
PY AR
SWAM
VICINITY MAP
PRO
MECHANICAL
VIS
ION
NOT TO SCALE
OF
PRIM
ARY
43.3
PER
IME
4
TER
FEN
FIRE SAFETY
CE
OF P
RIM ARY PER
IMET
ER FE
NCE
2
ISION
PROV
E
FENC
ETER
PERIM
RIM ARY
OF P
ISION RECOMMENDING APPROVAL:
PROV
64.19
PY AREA
3 SWAM
APPROVED:
PROJECT TITLE: DRAFTED BY: CHECKED BY: RECOMMENDING APPROVAL: APPROVED BY: SHEET CONTENT: SHEET NO.: