PRINCIPLE FEATURES
RF-Capacitance level Transmitter utilizes the 4~20mA 2 wire Loop power
capacitance formed between the sensing probe and Low consumption of power (20mA Max)
the reference probe which is the metallic vessel wall to High accuracy of linearity ( A1% FS)
calculate the level of the liquid/medium inside the Temperature compensation, low temperature
vessel according to the capacitance theory that the effect (A1% FS / 30BC).
capacitance and vessel are proportional increased. Easy calibration (Any 2 points for calibration)
Wide measuring range for capacitance
RF-Capacitance level Transmitter utilizes RC (0~2000PF)
oscillating circuit to create a high frequency signal in No blind distance, ideal for different tanks.
which the frequency is reverse proportionate to the Suitable for high temperature, high pressure
capacitance C where the microprocessor is applied to and corrosive environment.
measure the frequency for calculating the capacitance
and corresponding to the level in order to control the
current volume of 2 wire loop power.

APPLICATION
Brewery Plant
Paint Manufacturing Plant
Cement Plant
Food Processing Plant
Flour Mill
Glass Industry
Water And Waste Water Treatment
Medical Plant
Power Plant
Tar Factory
Beverage Plant
Level
Plastic Plant

PB Series Recorder
Bargraphic 4~20mA
display
Panel Meter

EB RF-Capacitance level Transmitter

PM Series
digital display Panel Meter

1
FlneTek
STANDARD SPECIFICATION

f113 f113
f113
1/2"NPT 1/2"NPT
1/2"NPT
108 108
108
f88
45 1-1/2"PT 50 1-1/2"PT
25 3"x5kg/cm2 25 1-1/2"x5kg/cm
2
45 1-1/2"PT
f180 f120
25 3"x5kg/cm
2

f145 f180 f95


f20 f19 f15
f145 f20
L=50M (Max.)

f20 f19
Dimensions

L=50M (Max.)
(unit:mm)

L=4M (Max.)
f9.5 wire

Ceramic f9.5 wire


f12.7
Ceramic
114
114
64
64

Model No. EB2100 Wire Probe EB2101 Hi-Temp Wire Probe EB2200 Rod Probe

Probe material SUS304 SUS304 SUS304/316

Weight material CERAMIC CERAMIC

Ambient
-40~80BC -40~80BC -40~80BC
Temperature
Operating
0~100BC 0~200BC 0~100BC
temperature

Tensile strength 3500Kgf 3500Kgf

Operation
12~36Vdc 12~36Vdc 12~36Vdc
voltage

Output current 4 ~20mA 4 ~20mA 4 ~20mA

Measuring
0~2000pF 0~2000pF 0~2000pF
Range

Accuracy A1%FS A1%FS A1%FS

Housing IP
IP65 IP65 IP65
Degree
1-1/2"x5kg/cm2
Connection 3"x5kg/cm2 or 1-1/2"PT Screw 3"x5kg/cm2 or 1-1/2"PT Screw
or 1-1/2"PT Screw

Weight Approx. 3.7kg(1M) Approx. 4.2kg(1M) Approx. 2.3kg(1M)

Operating
15kg/cm2 15kg/cm2 15kg/cm2
pressure

2
FlneTek
STANDARD SPECIFICATION

f113 f113
f113
1/2"NPT 1/2"NPT
1/2"NPT
108 108
108
f88 f88
50 50
45
1-1/2"PT 45
25 1-1/2"x5kg/cm
2 1-1/2"PT
f120 f20
1-1/2"PT
f20
f95

L=50M (Max.)
f20 f15

L=50M (Max.)
Dimensions
(unit:mm) f9.5 wire
L=4M (Max.)

f9.5 wire

SUS 304
SUS304
f12.7 150
150
f38
f38

Model No. EB2201 Hi-Temp Rod Probe EB2300 Wire Probe EB2301 Hi-Temp Wire Probe

Probe material SUS304/316 SUS304 SUS304

Weight material SUS304 SUS304

Ambient
-40~80BC -40~80BC -40~80BC
Temperature
Operating
0~200BC 0~100BC 0~200BC
temperature

Tensile strength 3500Kgf 3500Kgf

Operation
12~36Vdc 12~36Vdc 12~36Vdc
voltage

Output current 4 ~20mA 4 ~20mA 4 ~20mA

Measuring
0~2000pF 0~2000pF 0~2000pF
Range

Accuracy A1%FS A1%FS A1%FS

Housing IP
IP65 IP65 IP65
Degree
1-1/2"x5kg/cm2
Connection 1-1/2"PT 1-1/2"PT
or 1-1/2"PT Screw

Weight Approx. 2.8kg(1M) Approx. 2.3kg(1M) Approx. 2.8kg(1M)

Operating
15kg/cm2 15kg/cm2 15kg/cm2
pressure

3
FlneTek
STANDARD SPECIFICATION

f113 f113

1/2"NPT 1/2"NPT

108 108

1-1/2"PT 1-1/2"PT
25 1-1/2"x5kg/cm
2

f120
f95 f20

L=50M (Max.)
f15
L=4M (Max.)

Dimensions
Wire
f8
(unit:mm) FEP Coating
f12

PTFE
f16
150

f38

EB2400 --- PVDF Coating EB2510 --- Nylon Coating


EB2420 --- PP Coating EB2520 --- PP Coating
EB2430 --- FEP Coating EB2530 --- FEP Coating

Model No. EB2400/20/30 Anti-Corrosion EB2510/20/30 Anti-Corrosion

Probe material SUS304+Coating SUS304+Coating

Weight material SUS304+PTFE

Ambient
-40~80BC -40~80BC
Temperature
Operating
0~100BC 0~100BC
temperature

Tensile strength 1200Kgf

Operation
12~36Vdc 12~36Vdc
voltage

Output current 4 ~20mA 4 ~20mA

Measuring
0~2000pF 0~2000pF
Range

Accuracy A1%FS A1%FS

Housing IP
IP65 IP65
Degree

Connection 1-1/2"x5kg/cm2 1-1/2"PT

Weight Approx. 2.3kg(1M) Approx. 2.3kg(1M)

Operating
15kg/cm2 15kg/cm2
pressure

4
FlneTek
SETTING FLOWCHART FOR EACH FUNCTION

A: B: C: D: E: F: G: H: I: J:
K: L: M: N: O: P: Q: R: S: T:
U: V: W: X: Y: Z:

Setting for decimal:


using shifts digit position from 0~3.

View preset value, preset value is 0.

Setting for 4mA corresponding value:


using changes the setting value.

View preset value, preset value is 0

Setting for 20mA corresponding value:


using change the setting value.

View preset value, preset valueis100.

Calibration for low level display:


using changes the setting value.

View preset value, preset value is 0.

Calibration for high level display:


using changes the setting value.

View preset value, preset value is 100.

5
FlneTek
INSTALLATION

1. The rod probe or cable probe (depending upon which


one you purchased ) should be parallel to the tank
wall and be positioned as close as possible to the
tank wall. Make sure the medium does not stick in
between the probe and the tank wall. Metal strap

2. If the tank is not electrically conductive, a metal


strap should be added outside of tank wall (fig. 1) for
either liquid or non-liquid medium. Or place a metal
tube, usually made out of stainless steel, around the
rod (fig. 2) for liquid medium. This metal tube should
come with a vent hole at top of the tube to allow the Rod probe
medium to go up inside of the tube.
3. If the container is irregular shaped, such as a
cylindrical, and the medium is liquid with low
viscosity, the rod should be place inside a metal tube
with vent hole at the top. (fig. 2)
4. The cable probe should be routed through the
Fig. 1
ceramic insulator and tightened with the fixing bolt,
finally it should be routed through the silo and firmly
attached to the cable nut. (fig. 3)
5. Make sure to fix the rod probe or cable probe to the
container wall with non-conductive supporting
material. If an agitator is in place (see fig. 4). This Tube Vent hole
will prevent the deformation of the rod probe and
tangling of the cable probe around the agitator.
6. If the medium is conductive, make sure to coat the
rod probe or cable probe with PVDF or PP material.
7. During the installation, the process connection
should be grounded. An installation without proper
grounding will not guarantee normal operation of the
device later on. Fig. 2 Rod probe
8. When all electrical connections inside of a
Capacitance Level Transducer housing are finished,
the housing cover and the conduit opening should be
sealed and tightened to prevent moisture from
ruining it.

Cable probe
Isolate supporter

Rod probe
Agitator

Ceramic isolator

Fig. 3 Fig. 4

6
FlneTek
CODE NAME INFORMATION

EB

EB2100 --- Wire-probe with Ceramic weight


EB2 20 0 --- Rod Type
EB2300 --- Wire-probe weight Type
EB2499-- Anti-Corrosion
(2400: PVDF 2420: PP 2430: FEP)
EB2599-- Anti-Corrosion with Wire-probe weight
(2510: Nylon 2520: PP 2530: FEP)

Connecting
B---1/2" M---5kg/cm 2
C---3/4" N---10kg/cm 2
D---1" O---150 Lbs
E---1-1/2" P---300 Lbs
F---2" Q---PT pipe thread
G---2-1/2" R---PF pipe thread
H---3" T---BSP pipe thread
I---4" U---NPT pipe thread
J---5" V---G pipe thread
K---6" S---Special spec.
S---Special spec.

Length L (UNIT: mm)

* Tolerance of the total product length is 65mm


* Characteristics, specifications and dimensions are subject to change without notice.
* Please contact your nearest distributing office for further informations.