lighting circuit
individual branch circuits
all of the choices are correct
small appliances circuits
Monitor for over and undervoltage, overcurrent, over and under frequency reverse power and earth
faults.
When two compound generators are connected in parallel, when load current in generator 1 is increased
__________
current transformer
buck-boost transformer
control transformer
potential transformer
Overloading
Overvoltage
All of the choices are correct
Over speed
Electrical conduits and other non-current-carrying metal equipment are grounded to ________.
Overvoltage
Over speed
All of the choices are correct
Overloading
of 10,000 volts
equal to 150% of the system voltage
equal to the system voltage
equal to or greater than the system voltage
In electrical distribution systems helps prevent accidents to personnel and damage to property caused by
fire in case of lightning; a breakdown between primary and secondary windings of transformers; or
accidental contact of high-voltage wires and low- voltage wires.
Is a phenomenon in which an electric current pass through the air or another insulating medium,
creating a
luminous electrical discharge.
latching
arcing
grounding
earthing
External characteristics
Internal characteristics
Both internal and external characteristics
It doesn't depend on load sharing
When a ground-fault protector is being installed on the supply conductors, it must __________.
latching
arcing
relay
contactor
_________ is electrical power that is provided by commercial generating systems to the facility.
utility power
diesel power
single or one-line diagram
none of the choices are correct
safety valves
current increasers
current reducers
testing devices
GCI
GFCI
GFC
ICFG
This occurs when the generator produces a voltage higher than the rated or expected value.
Over speed
All of the choices are correct
Overvoltage
Overloading
_________ of a distribution system is a simple and easy-to-read diagram showing power supplies, loads,
and major
components in the distribution system.
utility power
single or one-line diagram
diesel power
none of the choices are correct
The function of a ship's distribution system is to safely convey the general electrical power to every item
of consumer equipment connected to it. The most obvious element in the system is the _______, i.e.,
the ship's main
switchboard.
main board
main distribution system
protection
transformer
Designed to cause the prompt removal of any part of a power system that might cause damage or
interfere with the
effective and continuous operation of the rest of the system.
Interconnect the high voltage and low voltage distribution sections of the system.
short circuits
overcurrent
leakage currents
high voltages
While connecting two DC generators in parallel, which of the following is not a desirable condition?
The primary distribution system consist of the wiring between the ________.
utility power
single or one-line diagram
none of the choices are correct
diesel power
transformer
main board
main distribution system
protection
It is an electrical component or device that functions as a switch to control the flow of electric current
within an
electrical circuit.
contactor
arcing
relay
latching
It happens when the generator is forced to deliver more electrical power (current) than it is designed to
handle safely. This can lead to overheating, increased wear and tear, and potential damage to the
generator components.
Over speed
Overvoltage
Overloading
All of the choices are correct
When two DC series motors are connected in parallel, the resultant speed is __________.
Normal speed
Loss than the normal speed
Zero
More than the normal speed
_______ supplies bulk power motor group starter boards, section boards and distribution boards.
transformer
main distribution system
main board
protection
Refers to a state in which a device or circuit maintains its current state or position without requiring a
continuous
external signal to keep it in that state.
relay
earthing
arcing
latching
Electrical hazards include shock, electrical arcs and blasts, and _____or faulty equipment.
Select the correct response:
Secure
Polished
Double-insulated
Broken
One of the main functions of personal protective grounds is to provide a _______ impedance path for a
short circuit.
Select the correct response:
Smooth
Low
Adequate
High
Which of the following is the main reason to affect the DC motor speed?
Select the correct response:
Back emf
Flux
Load
Armature current
What is the function of a starter in a DC motor?
Select the correct response:
It reduces the motor speed
It restricts the starting current for protecting
It stops the motor
It controls the motor speed
Acceptable standards of safety are issued by various bodies, including national governments,
international governmental organizations such as:
Select the correct response:
IEE
SOLAS
Lloyd's Register
BS and IEC
____ gives a stray current somewhere to go and keeps workers from becoming part of the circuit.
Select the correct response:
De-energizing
Grounding
Energizing
Guarding
Which of the following is used to restrict the maximum torque in the DC motor?
Select the correct response:
Speed
Heating
Armature current
Commutation
Specially designed PPE for electrical work includes _____ insulating gloves, matting, blankets, and covers.
Select the correct response:
Wood
Plastic
Steel
Rubber
The amount of force acting on a current-carrying conductor in a magnetic field is proportional to ____.
Select the correct response:
all of the choices are correct
and amount of current flowing in the conductor
the strength of the main flux
the length of the conductor within the field
This type of DC motor is constructed such that the field is not connected to the armature. This type of DC
motor is
not normally used.
Select the correct response:
Compound Wound DC Motor
Externally-excited DC motor
Shunt Wound DC Motor
Series Wound DC Motor