The premise for fantastic solutions
Nicotra Gebhardt employs around 1000 mem- Our activities are based on our core compe-
bers of the staff in nine production sites and tences:
has sales organisations in France, Belgium, the J erodynamics
A
United Kingdom, Sweden, Spain, India, China, J Acoustics
Thailand, Singapore, Malaysia, Australia, and the J Drive Technologies
USA. In addition, our sales agents and distribu- J Controls
tors are active in more than thirty countries for
Ongoing product improvements, highest quali-
keeping in contact with our customers.
fication of our R&D Teams, intensive quality con-
We offer high performance fan systems based trol, and most modern manufacturing methods
on Centrifugal, Roof, Axial, and Process Air Fans ensure the consistent high standards of our
both for series requirements and for single pro- products.
ject business.
1988-1992
Singapore - Thailand - Malaysia - UK Spain - Netzschkau DE
Headquarter in
Germany Motors production
1993
Motors production
1994-1997
Industrial Process Fans
Nicotra Gebhardt Singapore & Malaysia
GmbH
2003
Gebhardtstrasse 19-25 China - India USA
Germany
2
Aerodynamics – Acoustics – Drive Technologies – Controls
Our laborarories, powered by test equipment There are numerous patents and protective rights
which complies with all international directives which confirm the innovative activities of our en-
and the most modern standards, are the centre gineers.
of research and development manned by highly All this, an outstanding expertise, highest quality
qualified employees. standards, and an exemplary mind for cost effec-
We hold core competences in the field of aerody- tiveness make us one of the leading manufactur-
namics and acoustics related to our products as ers of fan systems.
well as in drive technologies and the dedicated
controls.
Noise measurements
to DIN 45 635-38
„Noise Measurement
of Machines: Fans“
3
Belt Driven Centrifugal Fans
ASH / AS
J s izes 0160 up to 1000
J t win fan arrangement
series ADH-G2
J s ingle inlet centrifugal
fan series ASH
J s eries AS with inch di-
mensions from 7/7
up to 30/28 RDH-G2
4
Highest system
Performance areas 5000
Pa RZR/RER
RDH/RSH
1000
ADH/ASH
AT/AS performance
500
and best energy
psF
efficiency!
100
100 1000 10.000 100.000
qV m³/h
RZR RER
Belt driven centrifugal fan with double inlet. Belt driven centrifugal fan with single inlet.
Data according to tolerance class 1 Data according to tolerance class 1
RZR-BIG
5
Direct Driven Centrifugal Fans
DDM / DDMB DD
The thousand times proven direct driven centrifugal The thousand times proven direct driven centrifugal
fans for compact ventilations and air handling units. fans for compact ventilations and air handling units.
J automated manufacture of compact scroll J automated manufacture of compact scroll
J automated manufacture of impeller with forward- J automated manufacture of impeller with forward-
curved blades curved blades
J built-in, optimised external rotor motor J built-in, optimised internal rotor motor
J motor with AC or brushless DC technology J low vibration and low-noise
J low vibration and low-noise J ready to connect, compact and maintenance free
J ready to connect, compact and maintenance free
SAIR SAI
Single inlet fan with built-in external rotor motor Single inlet fan with built-in internal rotor motor
6
Performance areas 2000 5000
Pa Pa
RZM/REM/RLM/TEM
1000
RZA/RZP
SAI 1000
DD(B) RLE
DDM(B)
SAIR 500
psF
psF
100 100
100 1000 10.000 100 1000 10.000 100.000
qV m³/h qV m³/h
RZM RLE EV O
Double inlet fan with coupled IEC standard motor Plug fan with brushless DC external rotor motor
with integrated control electronics
RZM
RLE E3
REM / TEM
Single inlet fan with flanged IEC standard motor
JR EM: Impeller with backward curved blades
JT EM: Impeller with forward curved blades
7
Industrial Process Fans
P2M P4M
compact and universal – the ideal direct driven fan for powerful and versatile – the logical extension of the
many process air applications: P2M series with impeller diameters up to 1600.
P4K
with coupling
8
Performance areas 8000 8000
Pa Pa
P2M P4M P4R
5000 5000
Q2M
P4M
P4K
psF
psF
1000 1000
1000 10.000 100.000 1000 10.000 100.000
qV m³/h qV m³/h
For more than 15 years we have been successfully active in the field of process air technology. With the knowledge of the requirements of your
branch our specialists can combine it with their own fan expertise to offer advice and solutions. Our industrial products stand for highest quality
and reliability. We offer and supply in a short time and cost effective customer specific process air fan solutions.
P4R Q2M
the belt driven series of the P4 - range with impeller Direct driven plug fans without scroll available in various
diameters up to 1600. models with impeller diameters up to 1400.
9
Roof Extract Fans
RGA RKM
Efficient technology, high quality workmanship, and an The RKA/RKM is the crowning glory of any roof.
ergonomical design make the RGA a highly attractive The roof extract fan was designed by a design studio
roof extract fan choice. so architectural integration of the fan can be guaran-
The RGA offers a new interpretation of the classical teed
cowl roof extract fan at specially attractive prices. J casing made of galvanised steel sheet
Je xternal rotor motor J IEC-standard motor RKM
Jh orizontal discharge J vertical discharge
Jc owl made of plastic J high throw protects the roof
J iF design award 2003
RFM RKA
Through its outstanding and beautiful pyramid shape J external rotor motor
the RFM gives a special note to every roof. J vertical discharge
J IEC-standard motor J high throw protects the roof
Jh orizontal discharge J iF design award 2003
Jc owl made of
galvanised steel sheet
FDA
J cubic styled roof extract
fans equipped with
highly efficient lining
reduces the discharge
sound level
KDM
J plastic roof extract fans particularly suitable for ex-
hausting aggressive gases or vapours
10
Performance areas Pa Pa
RDM
1000 1000
RDA
RFM RGA
KDM RKA
100 RKM 100
psF FDA
psF
10 10
100 1000 10.000 100 1000 10.000
qV m³/h qV m³/h
RDA / RDM
Roof extract fans genovent® The genovent® is saving cash at all levels:
The genovent® in every respect is a premium product: J because of extremely high value specification without
It’s convincing by its powerful design, its corrosion extra cost
resistant aluminium casing and multiple other technical J because of reducing heat losses.
refinements. J because of long lasting maintenance free operation.
J because of easy fitting without special tools.
J by simply fixing down the casing.
RDA 31
RDA 31/32
J external rotor motor
J stylish sealed casing manufactured from aluminium
J automatic backdraught shutters at discharge RDM 31/32
J vertically directed discharge - considerable throw
J integrated sound absorbing lining for series RDA 32
RDA 21
J horizontal discharge RDM 31/32
J IEC-standard motor out of airstream
J stylish sealed casing manufactured from aluminium
J automatic backdraught shutters at discharge
J vertically directed discharge - considerable throw
J integrated sound absorbing lining for series RDM 32
RDA 21
11
Smoke Extract Fans
REM
Smoke Extract Centrifugal Fans
Single inlet, with direct drive, suitable for smoke extrac-
tion in the case of fire up to
RDM max. +600 °C - 120 minutes,
Smoke Extract Roof Fans certified for installation outside of buildings,
ensuring a turbulence free discharge and suitable for tested to DIN EN 12101-3, and CE certified.
smoke extraction in the case of fire up to Can be used as a standard ventilation fan up to max.
max. +600 °C - 120 minutes, +100 °C.
tested to DIN EN 12101-3, snow load class require- REM BI (not illustrated)
ments SL 1000 assigned and CE certified. with insulating enclosure, certified for installation inside
Assigned for mounting above heated and unheated of buildings – outside room with fire risk
rooms. J Flow rate up to 31.000 m³/h
Can be used as a standard ventilation fan up to max. J Pressure up to 1.500 Pa
+80 °C.
JF low rate up to 58.000 m³/h
J Pressure up to 2.000 Pa
without insulat-
ing enclosure
RWM RER
Smoke Extract Wall Fans Smoke Extract Centrifugal Fans
suitable for smoke extraction in the case of fire up to single inlet belt drive, suitable for smoke extraction in
max. +600 °C - 120 minutes, tested to the case of fire up to max. +400 °C - 120 minutes,
DIN EN 12101-3, and CE certified for installation outside of buildings, tested to
certified. Can be used as DIN EN 12101-3, and CE certified. Can be used as a
a standard ventilation fan standard ventilation fan up to max. +80 °C.
up to max. +80 °C. Optionally with insulation
JF low rate up to housing for installation
37.000 m³/h inside of buildings, out-
JP ressure up to side room with fire risk
1.000 Pa J Flow rate up to
150.000 m³/h
J Pressure up to
3.000 Pa
12
Cleaner air for underground car parks
The Jetfan is the ideal solution for increased safety in underground Smoke flow simulation for perfect planning
car parks and underpasses. Choose the ultimate system for safer and
more aesthetic underground constructions
Centrifugal-Jetfan RGM We recommend the use of an airflow-simulation for large car parks
powerful standard product with centrifugal impeller, available in 2 sizes, with difficult geometries. It offers maximum planning dependability and
series RGM 96 for preventing CO-gas concentration, up to +40° C. is an invaluable tool for assessing the entire system.
AGM RGM
Axial Smoke Extract Impulse Jetfan Centrifugal Smoke Extract Induction Jetfan
suitable for smoke extraction in the case of fire up to suitable for smoke extraction in the case of fire up to
max. 300 °C – 120 minutes, max. 300 °C – 120 minutes,
tested to DIN EN 12101-3, and CE certified. tested to DIN EN 12101-3 and CE certified.
J Thrust up to 52 N J Thrust up to 75 N
AGM 02/12
AGM SLCS
Axial Smoke Extract Impulse Jetfan Smoke Extract Axial Fans
suitable for smoke extraction in the case of fire suitable for smoke extraction in the case of fire
up to max. 300 °C – 120 minutes, tested to SLCS 300 °C – 120 min.
DIN EN 12101-3, and CE certified. SLCS 400 °C – 120 min.
J Thrust up to 52 N J Flow rate up to 75.000 m³/h
AGM 01/11
13
FFU, Cabinet Fans, Axial Fans
FFU
Fan Filter Units
Construction materials:
J galvanised steel sheet
J aluminium zinc coated
J aluminium
J stainless steel
Network Topology:
J G BUS
J Modbus-RTU
J LONWORKS®
14
Network Topology: FFU Fire Alarm Printer SMS E-Mail Control OPC Worldwide
Dry Contact Paging Client Client Remote
Gateway Access
The Nicotra Gebhardt Router
Repeater
FFU Monitoring and
Digital Input Module
Control System consists Temperature Sensor Ethernet, 10/100 Mbps
of a FFU control network Network Terminator
connected to a compu FFU Control Centre
terised FFU Control cen-
tre. This FFU System is
LONWORKS® G BUS
especially made for the
high demands of clean
room applications. Lonworks FTT-10 A, 78 kbps Ethernet, 10/100 Mbps
The FFU Control centre
allows control of a large Hub/Switch
quantity of FFUs in a very Ethernet, 10 Mbps
flexible and future ori-
ented way.
At the heart of the system
is a control centre (server) Handheld
service tool RS485, 9600 bps
which contains network
management, process
control and web server as
main parts.
15
Nicotra Gebhardt worldwide
SPAIN
Ctra. Alcalá-Villar del Olmo, Km. 2,830
28810 Villalbilla-Madrid
Phone +34 918-846110
Fax +34 918-859450
E-mail info@nicotra.es
BELGIUM
Haeghensgoed, 13 - 00/01
9270 Laarne
Phone +32 (0)9-336-00-01
Fax +32 (0)9-336-00-05
E-mail info.nicotra@nicotra.be
FRANCE
Leader's Park Bat A1
3 chemin des Cytises
69340 Francheville
Phone +33 (0)4 72 79 01 20
Fax +33 (0)4 72 79 01 21
E-mail g.cauche@nicotra-gebhardt.com
16