You are on page 1of 1

1 PROJECT DESCRPTION & DETAILS

2.2 SUB-STRUCTURE DETAILS

 The foundation system shall be of Open type for the main buildings and other ancillary buildings according
to the Geotechnical report. Isolated and combined footing had been adopted for this building.

 The soil springs shall be considered as per Geotechnical report.

2 ANALYSIS AND DESIGN METHODOLOGY


The structural analysis is to be carried out using ETABS for both vertical (Dead & Live loads) and lateral
loads (Seismic and wind loads) for different load combinations. Response spectrum analysis shall be
done for structural performance of the building. Foundation shall be designed in spreadsheets or
SAFE software.
All concrete design shall conform to IS: 456-2000, IS: 13920-2016, IS: 1893 (Part1)-2016 and all other
relevant codes as applicable. The structural system is designed to resist the total design force in
proportion to their lateral stiffness considering the interaction each floor levels.
The structural system will have column beam frame arrangement with suspended slabs supported
over beams. Shear walls shall be provided for resisting lateral forces according to the design
requirement.