You are on page 1of 4

MAINTENANCE MANUAL AS532MK1

Air data systems - Servicing


301 Circuit bleeding
A. References
34-00-00-301 ................................. General instructions
20-02-06-402 MTC
20-02-06-409 MTC
B. Special Tools

ICO 91.50.00.02.020 .................... hydraulic system tool kit


Airborne kit ................................... static pressure port protective cover
Airborne kit ................................... pitot head protective cover

C. Consumable Materials
CM 776 ......................................... Lockwire
CM 780 ......................................... Snap wire
CM 683 ......................................... Locking compound
D. Routine Replacement Parts
None

E. Preliminary steps
(1) Open and/or remove:

(a) LH forward bottom structure inspection door under copilot cabin floor,

(b) electrical cabinet,


(c) small cabin floor panel in front of electrical cabinet,

(d) static port and pitot head protective covers [ Airborne kit].

F. Procedure
(1) Switch static and dynamic pressure circuit shut-off valves (1) - (2) to "N".

(2) Switch static pressure [ Airborne kit] selector valves (3) to "N".
(3) Disconnect the air data unit, AP (5), landing gear microswitch (6) and according to
version, compensated airspeed indicator/generator (14).

(4) Plug the disconnected pipes.

(5) Disconnect static and dynamic pressure hoses (8) - (10) at pilot and copilot manifolds (7)
- (11) behing the instrument panel.
(6) Connect nitrogen cylinder hose to the static and dynamic pressure lines (8) - (10) in turn.

(7) Adjust pressure to 1 bar (14.5 psi) then blast the circuit with nitrogen:

(a) check that the nitrogen escapes from static port and pitot head (4) - (13) orifices,
(b) push in drain valves (12) and check that nitrogen escapes,

34-11-00-301 Page 301


2013.07.18
MAINTENANCE MANUAL AS532MK1

(8) Close static and dynamic shut-off valves (1) - (2).

(9) Push in drain valves (12):


(a) nitrogen should not escape.

(10) Open shut-off valves (1) - (2), drop the nitrogen pressure.

G. Final steps

(1) - Disconnect the AP air data unit, the landing gear microswitch blanking covers and,
according to version, compensated airspeed indicator generator (14).
PRE MOD 0726357:

- Connect all static and dynamic pressure lines and wirelock.


POST MOD 0726357:

- Coat the unions with Locking compound CM 683 as per MTC and connect all the
static and dynamic pressure lines (8) - (10).
- Fit snap wire to shut-off valves.
- Checks for leaks.
- Install protective covers.
- Install and close the floor and inspection doors.

34-11-00-301 Page 302


2013.07.18
MAINTENANCE MANUAL AS532MK1

Figure 301

34-11-00-301 Page 303


END OF MODULE 2013.07.18
34-11-00-301 Page 304