Editorial
• is the software selected for the analysis appropriate for the given
application?
• how will the structure resist all loads and where are the load paths?
• It is important to verify the results from the model and for the more
experienced engineer this may be by “gut feel” and a review of the
deflected shape produced by the model. For the less experienced, the
very minimum should be self-checking by simple hand calculations.
common sense and experience are that designers do not make use of Benefits of CROSS
also needed as it is important to available published information to
understand the background of the establish initial sizes before inputting • Share lessons learned to
software and its limitations. data into modelling programs. For prevent future failures
example, the Guide to Long-Span • Spurs the development of
In a real structure, the behaviour of
Concrete Floors> published by the safety improvements
individual elements under load can be
Cement and Concrete Association • Unique source of information
complex, depending on the materials
of Australia (CCAA), which is
used and many other factors. In • Improved quality of design
free to download and should be
analysis, idealised models of the and constructon
taken into account. The reporter
frame or structure are developed to • Possible reduction in injuries
further recommends the Institution
simulate how the real structure may and fatalities
of Structural Engineers two-day
behave. However, it is important
online course on Understanding • Lower costs to the industry
to remember that they are just
structural design> which extends the
mathematical models and engineers
(especially those less experienced)
principles developed in the earlier Supporters of
Understanding Structural Behaviour>
should ask themselves the following: CROSS-AUS
course to more complex, real
• is the model correct and does it structures and the all-important skills • Australasian Certification
correctly and appropriately represent of approximate analysis for checking Authority for Reinforcing and
the structure under analysis? computer output and member sizing. Structural Steels (ACRS)
• how will the structure resist all loads On a multi-storey project reviewed by • Consult Australia
and where are the load paths? the reporter, the concrete cores were • Engineers Australia (EA)
assumed to be cantilevered from the • Engineering New Zealand
• was a second opinion obtained
basement and to resist all the lateral (ENZ)
within their office on the model they
load from wind and earthquake.
have adopted? • Institution of Structural
However, the cores were laterally
Engineers (IStructE)
• did they model some alternatives in restrained by the ground floor which
case the original assumptions are in turn was acting as a diaphragm • Structural Engineering Society
not correct? connected back to concrete retaining New Zealand (SESOC)
walls. It is more probable that the
• how did they model large
cores were cantilevering above
penetrations in floors for stairs and
the ground floor and not from the
the like?
basement as assumed. Furthermore,
As an example of incorrect modelling, in reality, significant additional
the reporter has reviewed several horizontal loads would be applied to
projects where deflections of concrete the retaining walls.
floors were an issue, particularly for
When modelling the effects of lateral
buildings designed in the 1970s and
load, it is important to understand
1980s. Based on the modelling, these
the role of all vertical elements. For
floors appeared to be satisfactory but
example, it is often not sufficient
based on real-life performance they
to ignore the effects of other load-
were not. This highlights that there is
bearing elements (such as precast
no substitute for a critical review of
panels or columns) as they may
the results.
take some portion of lateral load
depending on the relative stiffness of
each element.
There is no
The reporter points out that clause
substitute for a 5.2.3 of the Australian Earthquake
critical review of Standard for buildings AS 1170.4
requires that all stiff components be
the results considered as part of the seismic
force-resisting system and designed
accordingly unless they are separated
such that no interaction can take place
Deflection of concrete floors has
as it undergoes deflection due to
been a vexed question for many
earthquake effects. Yet the reporter has
years (particularly for reinforced
seen projects where load-bearing pre-
concrete floors) and the reporter
fabricated concrete walls and columns
notes that deflection limitations in
have not been included in the analysis
Australian Standard AS 3600 are
and all of the actions are assumed to
minimal requirements and may
be taken by the central core.
not be appropriate for all projects.
The reporter is also concerned
C Expert Panel
It is important to verify the results News & Information
from the model and for the more
Comments experienced engineer this may be by CROSS-AUS Presentations:
“gut feel” and a review of the deflected Colin Caprani, Director CROSS-
Today’s structural engineers have a shape produced by the model. For the AUS gave a presentation
wide range of tools available that less experienced, the very minimum on CROSS in June to the
allow fast and detailed analysis of should be self-checking by simple hand Association of Consulting
different structural forms. However, calculations to check that the results Structural Engineers Victoria
it is important to clearly understand (e.g. span/depth ratios) are of the (ACSEV)>. As Colin notes “it
the assumptions, simplifications and right order, and that the total support was extraordinarily positive
the basis of any software being used reactions are equal to the overall loads and I derived great satisfaction
for modelling the structure. As the applied. For complex structures, a very from seeing how positively
reporter points out, the software used simplified model may be used as a our work is received”. If your
for structural analysis is based on comparison to check the expected load organisation or workplace
an idealised mathematical model of path and to provide a “sense check” for would like to learn more about
the structure. There are limits to how the more complicated model with all CROSS drop us a line at team.
accurately the models can represent the elements included. aus@cross-safety.org>
real structure in its real environment. It is well established that human
When correctly used, structural errors are the cause of most structural
modelling can provide the engineer failures and a European research
with a solid grasp of the upper and project - The human factor in Professional Registration
lower bounds to any design on which structural engineering: A source of in Australia:
they are working. Simple models can uncertainty and reduced structural
safety> - has studied how subjective If you are seeking professional
be used to understand the results
decisions, individual knowledge and registration status in the
of more complex models and all
the use of advanced tools and codes states of Queensland or
modelling should be considerate
affect structural safety and structural Victoria you can apply via the
of likely construction tolerances,
design. This research revealed a large IStructE’s assessment schemes.
secondary effects, and serviceability
variation (around 300%) in results Membership of the IStructE is
implications (vibrations, accelerations,
when a common design task was not necessary.
line of sight, etc.). It is also important
to consider the effect on structural carried out by different engineers Full details of the application
behaviour from temperature changes, and introduces the term Engineering requirements, assessment
concrete shrinkage, and the possibility Modelling Uncertainty (EMU). process and application
of unexpected loads (robustness). If Further examples of incorrect modelling forms can be found on the
the material response is ductile the of structures that may go undetected Queensland> or Victoria>
consequences of overlooking such are outlined in two investigations of pages of the IStructE website.
effects may be limited, but if the existing bridge capacities that make
material response is brittle, these sobering reading:
effects may lead to failure.
• The UK Highways Agency Contract
2/419 Technical Audit of the Engineering New Zealand:
Application of BA79 A Review of Te Ao Rangahau has initiated
Inherent Bridge Assessment Failures on a new programme called
Pritchard and Heywood: Bridge These risks can be mitigated as follows: CROSS-AUS report 960 “The
Analysis: are we data managers myth of quality assurance”>
• ensure the competency level of the
or engineers?> TMR conducted has generated some lively
modelling and analysis software
an audit of around 500 desk- discussion in both LinkedIn>
operator is adequate for the task;
top bridge assessments that had and Engineers Australia’s
been carried out by different • undertake suitable quality control EAX> on the role of the design
consultants. This found a range based on level of risk; engineer during construction
of errors including errors in the and who should be
• undertake independent verification
use of 3D models, inappropriate responsible for certifying that
and validation based on the level
software defaults and incorrect the finished works comply with
of risk; and
load application. the design.
• having a quality control system
The CROSS Topic Paper Reflective
in place that incorporates the
thinking> discusses similar concerns.
modelling, analysis and
Reflective thinking is a constant
model transfers.
drive to ask questions and to make Attention is drawn to a recent
appropriate responses to them. It is The CROSS> database contains other report from the Insurance
characterised by a healthy scepticism examples of the problems associated Council of Australia (ICA):
about all inputs to processes, the with incorrect modelling. Attention Climate Change Impact Series:
processes themselves and about the is drawn to the recent report 1073 Tropical Cyclones and Future
outcomes from processes. Concern over modelling of concrete Risks>. Prepared for the ICA
frame building for construction by James Cook University
To summarise, the risks associated
stage>. This report stresses the Cyclone Testing Station in
with inadequate modelling include:
importance of considering the effect association with Risk Frontiers,
• models with assumptions about that the construction sequence may the report outlines the changes
boundary conditions, element have on the design and the need to required to building codes
interaction and unrealistic design the structure through all stages and construction standards to
structural behaviour; of its life. Failure to ensure that the improve the cyclone resilience
design and proposed construction of new homes, and calls for
• designers not understanding the
methodology are compatible may greater investment in the
limitations of software;
lead to a structure which is unsafe to retrofitting of old homes to
• inadequate time assigned build or indeed unsafe in use. protect property and lives.
to checking of models and
independent rudimentary first
principle checking for logical
Submit Report
output; and
The Bushfire & Natural
• standards and guidelines may Submit Feedback Hazards CRC has published its
not be suitable to cover the Hazard Note 112: The benefits
developments in software or of strengthening buildings
communications between designer, against earthquakes>.
detailer, fabricator or builder etc. Researchers at the University
of Adelaide and Geoscience
Australia identified the two
most vulnerable forms of
construction commonly used
in Australia – unreinforced
masonry buildings and low-
ductility reinforced concrete
buildings – and then examined
the most cost-effective
techniques available to
mitigate fatalities, damage,
business interruption and
heritage structure impacts.
• Promote transparency in the reporting of testing • Inform the regulator of deficiencies with test
procedures and results certificates, including how they are presented by
product manufacturers
• Ensure that manufacturer’s instructions are followed
for the installation of testing specimens
Section C (Fire Resistance) of the NCC requires that this Through their position, the reporter noted test certificates
Group Number is determined in accordance with AS where the Group Number of PVC or uPVC internal
5637.1:2015 Determination of fire hazard properties—Wall wall linings was derived “in accordance” with AS/NZS
and ceiling linings. This sets the decision pathway to choose 3837:1998. Based on the argument above, this can be
between the two available test methods: misleading as it does not follow the guidance outlined in
AS 5637.1:2015. These certificates are then provided to
• The first one is AS ISO 9705-2003 Fire tests—Full-scale
architects, builders, engineers, and building certifiers.
room test for surface products. A room of standard
Because these end-users look only for a test certificate that
dimensions is constructed from the lining to be tested.
references AS 5637.1:2015 at the top, they may be accepted
Following certain criteria, a Group Number can then
as valid without further questioning.
be derived. (CROSS panel’s note: ISO 9705 is a system
specific testing method, and that the results from an ISO The reporter has found that how test certificates are worded
9705 test cannot – in general – lead to a blanket Group can vary between test houses. It was also noted that some
Number assignment which is independent of the specific companies are quoting British or American Standards
jointing, mounting, and fixing methods employed in the without any evidence of expert assessments accompanying
test. This means that product-specific Group Number these certificates, which should state that the foreign
assignments are not strictly possible, unless the product is certificates are the same or better than the Australian
only used in the configuration employed when conducting Standard or test method.
the ISO 9705 test).
The reporter is worried that if the concern they raise is
• The second one is a smaller scale, oxygen calorimeter correct, some buildings in Australia have been lined with
test. Both the standards AS/NZS 3837:1998 Method of a material that may not necessarily be compliant with the
test for heat and smoke release rates for materials and fire requirements set out in the NCC. If that is the case, the
products using an oxygen consumption calorimeter or ISO reporter considers it vital to see all industry stakeholders
5660-1 Heat release rate (cone calorimeter method) and educated further on this topic, and some action put in place
smoke production rate (dynamic method) can be used. to catch ‘bad’ certificates.
with building professionals relying on such material for Designers, specifiers, producers, and certifiers should also
their designs. Professionals must satisfy themselves with consider what is actually being assessed via any given
the suitability of the chosen solution by using more robust regulatory/compliance fire testing method, and decide if
evidence than what may be available in marketing literature. the fundamental thermal physical underpinnings of the test
method may be violated by any particular building product.
The specific concerns raised in this report regarding
Many such test methods may have originally been derived
incorrect test application for establishing the Group Number
to assess specific materials or surface treatments, however,
of wall linings have previously been raised by the Australian
they may now be applied to products which have the
Building Codes Board (ABCB) and are covered in their
potential to violate various aspects of the testing philosophy.
guidance note>.
The distinction between ‘materials’, ‘products’, and ‘systems’
AS 5637.1:2015 is very clear on the decision pathway it should always be borne carefully in mind.
outlines. However, this is stated as “guidance”, and the
In conclusion, the panel considers that given the guidance
option is available to adopt cone calorimeter results when
from the ABCB on this matter, all building professionals
the Group Number can be “confidently predicted” with an
should be aware of the risks entailed when accepting a
appropriate mathematical model. Under this standard,
Group Number obtained through the cone calorimeter
the reporting of the Group Number results using the cone
results that do not satisfy the relevant sections of AS
calorimeter only requires a statement “that it was valid to
5637.1:2015. Where this is the case, they should be
test the material in the cone calorimeter for the assignment
requesting a clear robust explanation from the testing
of the NCC group number”. The panel is of the opinion that a
authority as to their justification and what empirical testing
more detailed statement setting out how it was determined
was used to form the basis of the prediction, otherwise only
would be more transparent. It is also observed that the
an AS ISO 9705 test – suitably limited in application based
Group Number certificates provided to CROSS by the
on the forming, mounting and fixing methods actually used
reporter do not contain this statement.
in the test, as is explicitly required by the ISO 9705 testing
To the panel’s knowledge, the current trend is that Certifiers standard – should be accepted. It is important that the
are increasingly aware of this problem, with some only process of setting up tests is open and that test results are
permitting the use of test results obtained through AS stated as being system specific.
ISO 9705 testing. However, more awareness is no doubt
The CROSS panel would encourage further reporting on
necessary and associations for accredited certifiers and
this subject.
building surveyors are encouraged to do more to raise this
issue with their members.
This report highlights the difficulty of inspecting continuously threaded reinforcing bars to
ensure that they have been adequately inserted into the cast-in ferrules.
When using such devices, it is very important to follow the manufacturer’s advice
and recommendations.
required performance, and the specification should require CROSS report 993 The use of cast-in ferrules as
the bars to be clearly marked at the required distance back structural connections> raises several issues with this
from the end of the bar. It would appear that this had not type of connection and notes that when cast-in ferrules
been done in the examples found by the reporter. and similar threaded inserts are used to make structural
connections using threaded reinforcing bar, the failure
When determining the required performance of the mode may be brittle. In this case, the design may not
connection, designers should take into account the particular comply with relevant AS/NZS Standards, such as the
location. For example, at floor slab-to-wall joints the bars ductility requirements in AS3600. Furthermore, AS 3850.1:
are likely to be subject to a combination of shear and axial Prefabricated concrete elements, makes it quite clear
loads as they transfer bending moments to the walls. that only bolts should be fixed into such ferrules for fixing
items such as lightweight architectural framing, temporary
As the reporter notes, winding in these bars is a labour- bracing, and the like.
intensive operation and any grit or cement dust on the
threads or inside the ferrule can make them difficult to National Precast Concrete Association Australia (NPCAA)
install to the full depth. Keeping protective plugs in the has produced a very informative Tech Talk (Webinar): Code
ferrules until just before they are used and keeping the Compliant Reinforcing Connections> (February 2022) on
threads of the bars well protected will go a long way to this subject.
eliminating this particular problem.
As the Steel Reinforcement Institute of Australia (SRIA)
Threaded reinforcing bars notes in its newsletter bearing issue number 43/4 of
December 2017 on “Mechanical Splices for Joining
It is important to differentiate between continuously Reinforcement”: ‘There are a number of proprietary
threaded bars which provide full capacity of the bar and systems available to mechanically splice reinforcing bars
those which rely upon a cut thread which reduces the bar in Australia, including both coupler and coupling sleeve
capacity unless a proprietary system is used, such as Ancon systems (both mechanically bolted and grouted), and
reinforcing bar couplers>. Again, it is very important to specific design and detailing parameters for the various
follow the manufacturer’s recommendations when using systems can be found via the links on our web site to our
such items. Associate Member manufacturers of these products.
Detailers should consult the manufacturer’s websites and
CROSS report 844 Defects in tapered thread examine the details to satisfy themselves on the type and
reinforcement bars for coupling> highlights the detail they should use and how to specify them. In some
importance of good quality control procedures on site for cases, mechanical splices are designed specifically for
the inspection of safety critical elements being delivered proprietary bar types, or to splice proprietary bars to
to ensure they meet the required standard. In this report ‘normal’ deformed reinforcing bars.’
reinforcing bars were observed to have visually different
tapered threads cut into the bars after delivery to site and
the reporter recommends the removal of couplers and
visual inspection of threads for randomly sampled bars Submit Report
when delivered to site.
Submit Feedback
This report describes a situation where site testing of post-installed fasteners in concrete
was undertaken by a contractor as an alternative to adopting the design data from the
manufacturer in an attempt to justify an increased design capacity for the fasteners. This led
to proposed design capacities which were about 3 to 5 times greater than the safe design
capacities determined in accordance with AS5216. Since these fasteners are located in a
safety-critical application, the reporter considered whether this may have resulted in an
unsafe condition.
The reporter encountered an issue where site testing of ETA assessment usually involves the testing of a large
post-installed fasteners in concrete was undertaken by number of specimens under various conditions over a
a contractor as an alternative to design data produced minimum period of 3 months, some of which are mandatory
by the manufacturer. This was undertaken to justify and some which are optional to qualify the product. For
increased design capacities for the fasteners which were example, the mandatory conditions include testing for
approximately 3 to 5 times greater than the safe design sustained load, variable loads, robustness and changed
capacities determined in accordance with AS5216: Design environmental conditions. These are extremely difficult to
of post-installed and cast-in fastenings in concrete. Since replicate on-site, and on-site testing cannot produce the
these fasteners are located in a safety critical application the same rigorous requirements as laboratory testing.
reporter considered whether this may have resulted in an The reporter notes that site testing, including ULS proof
unsafe condition. testing, is generally undertaken to identify any gross
A contractor had substituted post-installed chemically errors in the quality of the installation of the anchor.
anchored threaded rods in place of cast-in holding However, in order to address the shortfall in design
down bolts specified in the design documentation. When capacity the contractor in this case used the results of
the design capacity of the post-installed anchors was the on-site installation tests as the basis for establishing
subsequently checked using design data supplied by the the design capacity of the post-installed anchors. This
manufacturer of the fasteners, the values were found to be resulted in calculations for the design capacities of the
inadequate. The design capacities provided by the fastener fastener which exceeded the values of capacity based on
the manufacturer’s Technical Data Sheet (TDS) and/or ETA The reporter also notes that the requirement for post-
by a factor of between 3 and 5. installed fasteners to comply with AS5216 is relatively
new (that is circa 2019), and there appears to be little
Independent opinions were sought from two professional
awareness of the testing and qualifications of anchors
chartered engineers who also expressed the opinion that
required to satisfy AS5216 to ensure the safety and
the site testing could be relied upon as prototype testing
reliability of post-installed fasteners.
to AS1170.0 Appendix B to permit the use of a design
capacity 3 to 5 times higher than the design capacity In summary the reporter notes:
established by the manufacturer’s ETA. However, the
• Appendix A of AS5216 as referenced by the NCC2019 is
reporter notes that these site tests are not equivalent
a normative (i.e. mandatory) requirement which requires
to the suite of tests that are required by the European
that the testing of post-installed fasteners for suitability
Assessment Document EAD330499, which includes
and admissible service conditions be performed in
assessing effects of concrete cracking, epoxy aging, long
accordance with EAD330449;
term loading, etc.
• guidelines in AS1170.0 and AS4100 for the use of test data
The reporter notes that the Australian Engineered
for design are not satisfactory evidence of compliance
Fasteners and Anchors Council (AEFAC) Technical Note
with AS5216 (and NCC2019). These guidelines advise that
AEFAC-TN05-Site-testing-Vol 3> advises that the
there are several qualifications for the use of test data
characteristic strength obtained from site testing should
obtained in accordance with these referenced standards
not exceed capacities determined in the ETA; and that
which require variables or conditions not covered by test
clause B1.4 Determination of structural resistance of
procedures to AS1170.0 and AS4100 to be taken into
materials and forms of construction> in the National
account separately. These additional effects are explicitly
Construction Code NCC2019, Volume 1, Amendment
included in the EAD330499 approach required by AS5216
1, requires that post-installed and cast-in fastenings
(and NCC2019) and include:
comply with AS5216: Design of post-installed and cast-in
fastenings in concrete. • loading scenarios (such as dynamic, sustained and
combined loading);
Appendix A to AS5216 sets out the mandatory
requirements for testing and assessment of fasteners, • substrate conditions (such as cracked and
and requires these to be assessed in accordance with uncracked concrete);
the European Assessment Documents EAD330232
• durability and effects of aging;
(Mechanical Fasteners for Use in Concrete)> and
EAD330499 (Bonded Fasteners for Use in Concrete)>. • age and duration of loading;
Clause 1.1.2 Application in AS5216 also notes that “the
• environmental conditions; and
design parameters and product specifications required
for use with this Standard may also be obtained from a • in accordance with the advice from the Australian
current European Technical Approval/Assessment for Engineered Fasteners and Anchors Council (AEFAC) it is
the relevant fastener”. Alternatively, the same suite of recommended that characteristic strengths obtained from
tests that would be required by the European Assessment site testing should not exceed capacities determined in
Document EAD330499 can be undertaken by a Registered the ETA.
Testing Authority (RTA) in Australia and assessed by an
The reporter further recommends that the design resistance
Assessment Body which should be independent of both the
of an anchor should not exceed the values of design
manufacturer of the fastener and the RTA. This involves a
capacities published by the manufacturer without approval
large suite of tests and would not normally be undertaken
from that manufacturer.
at project level.
In conclusion, the reporter considers that the simplest way to
The higher design capacities based on site testing of ULS
ensure safe design of post-installed fasteners and compliance
if adopted would, in the reporter’s opinion, result in the
with NCC2019 and AS5216 is to specify a fastener selection
use of unsafe design capacities not compliant with the
for which a current European Technical Approval/Assessment
minimum safety requirements of NCC2019.
(ETA) is available for the fastener and installation method,
When a site pull-out test of an anchor is undertaken it and to adopt the design parameters documented in the ETA
is easy to understand how these test results might be for the design of the post-installed fastener.
accepted as representing an accurate assessment of
the anchor capacity accounting for the specific project
site conditions. However, these site tests are generally C Expert Panel Comments
undertaken in uncracked concrete for loads of short
duration without aging and environmental effects, and are The Panel fully endorses the reporter’s comments along
unlikely to represent the true design conditions. with the recommendations contained in the report.
The reporter notes that although the provisions for
prototype testing in AS1170.0 mention that these effects Concrete cracks under all types of loading including
must be taken into account using separate factors, there restrained concrete shrinkage, thermal loads, foundation
appears to be less awareness of the extent to which these settlement, dynamic loads, and extreme live loading.
affect the design capacity of post-installed fasteners. Testing anchors after installation is a poor indicator of their
capacity at the time when the anchor may be subjected to
critical loading. It is considered that the primary purpose of
the pull-out test [as envisaged by AS5216] is to verify that
there have been no gross errors in the physical installation In addition, particular attention needs to be paid to the
of the anchor, not as an abrogation of the responsibility to acceptability of chemical anchors in fire conditions, and in
design the anchor. such a situation as indicated by the reporter (i.e. change from
cast-in to post-fixed anchors), an application to the building
Anchor design in accordance with design values certifier for material change in system may be warranted.
provided by the manufacturer makes assumptions on
several variables (e.g. concrete strength), and assumes It is the considered opinion of the Panel that any decision
unreinforced conditions. If the anchor is found to require to circumvent compliance with AS5216 (as described in
additional capacity, it may be possible to refine the this case by the reporter) may create unacceptable and
accuracy of the variables whilst maintaining the integrity of avoidable risk, which, in the very worst-case scenario, may
the standard design process lead to injuries and/or fatalities.
Contact CROSS-AUS>
We publish and share safety reports, newsletters, any other publications and other documents,
information or content in a PDF format (the PDF Published Content). Such PDF Published Content does
not constitute commercial or professional advice. You should seek appropriate professional advice
before acting (or not acting) in reliance on any such PDF Published Content. So far as permissible by
law, we will not accept any liability to any person relating to the use of any such PDF Published Content.