11 y 12 [FC2]
11 y 12 Properties
General
Name 11 y 12 Number 2 Type FC Language LAD
Numbering Automatic
Information
Title Author Comment Family
Version 0.1 User-defined ID

Name Data type Offset Default value Comment


Input
Output
InOut
Temp
Constant
Return
11 y 12 Void

Network 1:

%I4.0 %M4.6 %Q4.7


"ENTRADA_CARRO" "PARO" "HORA"

%Q4.7
"HORA"

Network 2:

%DB1
"IEC_Timer_0_DB"
TON
%Q4.7 Time %M4.6
"HORA" "PARO"
INQ
T#60sPTETT#0MS

Network 3:

%DB1.DBD8
"IEC_Timer_0_ DB".ET
%Q4.3
>
"Led_time"
Time
T#40s

Network 4:

%DB1.DBD8
"IEC_Timer_0_ DB".ET
%M4.4
>
"Led_time_60"
Time
T#50S

Network 5:

%I4.0 %M4.0
"ENTRADA_CARRO" "M_PLUMA"
S

%I4.1
"SALIDA_CARRO"

Network 6:
Totally Integrated
Automation Portal

%M4.0 %Q4.2
"M_PLUMA" "LEDPLUMA"

Network 7:

%DB3
"PLUMA"
TON
%M4.0 Time %M4.1
"M_PLUMA" "M_PLUMA2"
INQ
T#4SPTETT#0MS

Network 8:

%M4.1 %M4.0
"M_PLUMA2" "M_PLUMA"
R