Training Manual
Chapter 16
Lights
Table of contents
16.1 Position Lights ................................................................. 4
16.2 Anti-Collision Light.......................................................... 6
16.3 Landing Light ................................................................... 8
16.4 Instrument Lighting ....................................................... 10
16.5 Passenger and Cargo Compartment Lighting ............ 12
16.6 Emergency Exit Light .................................................... 14
3
16 – Lights EC135 P3H / T3H
16.1 Position Lights B1
Training Manual
Position Lights
at approx. 43 times per minute while at the same time preventing pulse per minutes (+/- 4%).
loading of the aircraft electrical system. A power supply is integrated in The electronic system of light includes the current regulators, the clock
the light housing. The light is attached to the structure using mounting generator and switches. LEDs are soldered on an aluminum printed
hex nut and anti-twist pin. circuit board which is mounted on a thermal dissipation cylinder.
Anti-Collision Light
Landing Light Fixed in Nose Cover or Cross Tube Power Supply / Operation
Mounted
essential bus 2 via the circuit breaker LDGLT on the overhead console
General and the switch LDG LT installed to the control panel of the pilot’s and
copilot’s collective lever.
landing light is installed to the nose cover. If the light is switched on, the informaion message LDG LIGHT
The light is relocated to the RH or LH side of the forward crosstube in illuminates in the FND master list.
Landing Lights
General
The instrument lighting system installed to the helicopter helps to
Instrument Lighting
General Location
The emergency exit lights (LED EXIT sign lights) are installed in the
when there is a malfunction in the electrical supply system or during forward roof paneling above the sliding doors left and right. The Step
an emergency landing. exit lights are installed underneath the sliding doors left and right.
The emergency exit lighting allows the passengers to leave the The switch IMPACT is installed in the forward roof area. The EPSU is
The emergency exit lighting consists of the emergency exit lights (LED installed in the overhead pane. It has three positions: OFF, ARM and
EXIT sign lights) and step exit lights, which can be additionally added. ON.