( Reaffirmed 2003 )
Indian Standard
SPECIFICATION FOR
PLIERS FOR EXTERNAL CIRCLIPS
scope --Covers requirements for pliers for external circlips conforming to IS : 3075-1966
bimensions for circlips ‘,
!. Dimensions
TVPE A TYPE B
CYLINDRICAL CONICAL
ENLARGE0 OETAIL AT X
For Ex-ternal
Nom Tol
---
8 to 10
-‘- - -.-
20 to 25
----_ -....___
50 38 14 2’5 It;., 100 19 to 60
*Indicates the mlnlmum size of clrclip for which the plier shall be used.
tConformlng to IS : 3075-1965.
--_-_. ._._._._--_-_..____
3. Hardness - The hardness of the jaws shall be 440 f 60 HV5 ( ~44 f 5 HRC ).
4. General Requirements- The material, manufacture, workmanship, finish, preservation and packing
and sampling shall conform to IS : 2615-1964 ’ General requirements for pliers, -pincers and nippers’,
6. Test-The pliers shall be tested by opening five times the number and size of external circUpas
indiceted below and on the completion of test the pliers shall show no sign of deformation:
10 r i
ii P
100
105 :
‘300 1
+Conformlng to IS : 3975-1965.
tFor testing of pliers of nomlnal size, up to and lkludlng
40 mm, the two circllps shall be soldered together.
7. Marking - The pliers shall be marked with the type, nominal size and ~manufacturer’s name,
initials and/or recognized trade-mark.
7.1 IS/ Certification Marking - Details available with the Indian Standards institution.
EXPLANATORV NOTE
While preparing this standard, assistance has been derived from DIN 6264-1966 ’ Zengen fur
Sicheruhgssinge fur wellen ( Pliers for retaining rings for shafts ) ’ issued by Deutsches lnstitut fur
Normung.
2
Reproduced by~Reprography Unit, ISI, New Oelhl