Professional Documents
Culture Documents
1 Scope (mandatory)
Preparation of acid chloride of acetylated caffeic acid using oxalyl chloride and reaction. Followed by
preparation of acetylated caffeic acid phenethyl ester by the reaction of the acid chloride with
phenylethanol.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any amendments)
applies.
COSHH – Health and Safety Executive, “Control of substances hazardous to health (Sixth
edition)”, Health and Safety Executive, Stationery Office, Norwich 2013.
EH40/2005 – “Workplace exposure limits - (Fourth Edition)”, Health and Safety Executive,
Stationery Office, Norwich, 2020
HSG65 – “Managing for health and safety (Third edition)”, Health and Safety Executive,
Stationery Office, Norwich 2013.
Before any solvent is added to any bottle, pour the molecular sieve type 4A into each bottle to be
used to a depth of 10 mm.
The solvent N,N-dimethylformamide readily absorbs water and along with pyridine should be
transferred via air tight syringe and needle, with nitrogen filled balloon. The bottle used are shown
in Figure 1.
The types of bottles to be used and solvent type are shown in Table 1 and further details for
purchasing are set out in Table 8.
Dry dichloromethane
Dry toluene
Dry pyridine
Dry N,N-dimethyformide
Each fume cupboard to be used by students will need one bottle of each of the follow:
Dry dichloromethane
Dry toluene
Dry N,N-dimethyformide
Dry pyridine
To reduce moisture ingress, it is ideal that once solvents have been used in the lab session, they are
collected in by demonstrators and their lids checked.
Date received: Date at which the pack was received from the supplier
Date opened: Date at which the seal on the pack was broken
Table 2 Additional details
Date of fill: Date when the bottle was filled from the supplier's pack.
Technician: The person carrying out the filling.
Supplier: The name of the supplier of the raw material.
Supplier ID: The catalogue ID used to purchase the raw material from the supplier.
Supplier lot: / The unique serial number used by the supplier to distinguish production runs.
batch number:
Table 3 Additional labelling requirements for pharmacy student bottles
8 Drying tubes
Drying tubes are made up of an angled “Quickfit” drying tube, MF23/1 with desiccant and held in
place with glass wool. All the components required can be purchased from fisher scientific and are
listed in Table 8. The items are assembled as shown in Figure 2. The drying tube are kept in the
“Technicians Drying Oven”, shown in Figure 3.
Figure 2 Example of a drying tube, with a B14 connector, with desiccant trapped by glass wool
Once the reaction has run to completion, recover the solid material by vacuum filtration using a
Buchner funnel and flask. Wash the solid on the filter paper with a small amount of ice-cold
Deionised water. Dry the material using the Buchner funnel and then record the crude yield and the
appearance of your product. Whilst crude product is drying on the Buchner apparatus, heat 500 mL
of ethanol to boiling.
The filtrate still contains acetic anhydride and needs another 13 g of sodium hydroxide pellets to
neutralise it and make safe for disposal to the sink.
Re-crystallise the crude material using the boiling ethanol. After the solid has dissolved, remove it
from the heat and allow the solution to cool to room temperature. The crystals should form over a
period of 20 minutes. The crystallisation process is completed in an ice bath. Isolate the purified
product by Buchner filtration. Dry the product in the technician's drying oven shown in Figure 3.
Dispose of the ethanol filtrate to the non-halogenated waste.
Once the acetylated product is dry, run IR, melting point and nmr to confirm synthesis.Figure 3
Location of drying tubes
In addition, the safety, requiring students to tell the demonstrator the volume of oxalyl chloride they
need, “builds quality” in the multi-step synthesis. Using the mass of acetylated caffeic acid recorded
by the students the amount of oxalyl chloride can be read off from a simple “ready reckoner” to
check student calculations, (see section 11 Quantities per student).
During the lab a fresh bottle of oxalyl chloride should be placed in a large Gartrell's tray in a fume
cupboard. The bottle should only be opened while stood in the tray, this is to prevent any spillage
going direct to drain. Once the bottle has been opened and seal broken the top should be screwed
back on. The bottle should then be placed in a large 1 L beaker within the tray. To prevent the
bottle moving within the beaker it can be surrounded by tissue. The tissue also helps to clean up any
odd drops that fall when pipetting.
Normally transferring a liquid direct from a bottle is considered poor practice, but in the case of
oxalyl chloride the hazards outstrip this, so transfer direct from the bottle to student flask is carried
out. The tray should be used to transport oxalyl chloride from fume cupboard to fume cupboard.
The students should be asked to clear a space in their fume cupboard to allow the tray to be set
A 1000 microlitre autopipette with disposable tips are used to transfer the oxalyl chloride. A clean
pipette tip should be used for each transfer to minimise the risk of contamination of the oxalyl
chloride. After transfer the pipette tip should be ejected in to the 100 ml beaker containing 80 mL of
tap water.
Just as with oxalyl chloride, a 1000 microlitre autopipette with disposable tips are used to transfer
the phenethyl alcohol. A clean pipette tip should be used for each transfer. There is no need to
dispose of the tip in to water, simple disposal in the used “pipette tips and Pasteur pipettes” beaker
is fine.
Acetic anhydride
Formula: C13H12O6
Element amu Atoms
C 12.01 4 48.04
H 1.01 6 6.06
O 16.00 3 48.00
Mr: 102.09
Oxalyl chloride
Formula: C2Cl2O2
Element amu Atoms
C 12.01 2 24.02
Cl 35.45 2 70.91
O 16.00 2 32.00
Mr: 126.93 Density = 1.48 g/mL
Phenylethanol
Formula: C8H10O
Element amu Atoms
C 12.01 8 96.08
H 1.01 10 10.08
O 16.00 1 16.00
Mr: 122.16
15.14
Convert mmols to mols ¿ =0.01514 mols
1000
Mass of oxalyl chloride ¿ 0.01514 × 126.93=1.9215 g
mass 1.9215
Volume of oxalyl chloride required ¿ = =1.298 mL
density 1.48
Auto pipettes deliver volume in units of 5 microlitres
The lab script asks students to weigh the amount of diacetyl caffeic acid chloride produced and
calculate the addition of phenylethanol assuming 0.9 equivalence.
mass 2.1397
mols of diacetyl caffeic acid chloride ¿ =mols= =0.007569 mols
Mr 282.69
Convert mols to mmols ¿ 0.007569 ×1000=7.569 mmols
6.812
Convert mmols to mols ¿ =0.006812 mols
1000
Mass of Phenylethanol ¿ 0.006812 ×122.16=0.8321 g
mass 0.8321
Volume of Phenylethanol required ¿ = =0.8159 mL
density 1.02
Auto pipettes deliver volume in units of 5 microlitres
Converting mL to microliters and rounding ¿ 1.298 ×1000=815 μL
13 Materials to be purchased
All the items listed in Table 8 are taken from the Fisher scientific catalogue, selected as suitable for
this particular lab.