Sea Water System Design

1. Technology of Desalination :Reverse Osmosis


2. Plant Capacity :10,000 m3/d
3. Raw Water :Open Sea (Red Sea)
4. Candidate Membrane Element :SW30 HR LE 400 (13m3/d)
High active surface area
High rejection
Low energy
5. One stage system
6. Feed Temperature 25 °C
7. Percent recovery 40%

8. .If a higher recovery is required ……e.g. 45%

Modify the system array for this effect .


Selection of RO System Array

1. Number of Elements Required 770 element

2. Number of Pressure Vessels, if plant foot


print has no restriction, 7 elements – pressure vessels are selected

3. Array 110 pressure vessels in one stage

4. For increasing the system array to ………….45%

The array should be increased to……………..(130)7

The array may be also increased to lower the feed pressure to suit the original pump
pressure .