You are on page 1of 1

HPR_DN800 PN40_min zeta .

xlsx NeedleV-HydraulicChar

PLUNGER VALVE: flow analysis and cavitation check Rev 6.12


Upstream and downstream reservoirs at constant level

2
FLOW RATE CAVITATION CHECK
Cavitation value
Beginning of cavitation
Valve specification 2 Limit for light cavitation
Case A
Project HPR Existing
Case B
Nom.diam. DN 14
Nom.press. PN 40 3 1,00 1 1 0 No cavitation
1
Obturator type 2 150 20 200
Description DN 800 PN 40 - Standard (C) 35
Water temperature 20 °C 50
A B 1 75
1
Flow rate Q 1,39 1,39 3 100
1390 1390 [l/s] 150
Upstream pressure (dynamic) Pin 172,50 172,50 2 Controllo K cestello 0 172,50 172,50
1

Cavitation value sigma [---]


Downstream pressure (dynamic) Pout (*) 170,80 170,80 [m] 170,80 170,80
Pressure drop (valve) DP,v 1,70 1,70 [m]

Flow rate [m3/s]


Flow velocity v 2,77 2,77 [m/s] Vel. Limite condotta 6 m/s
Approx.valve opening a 100% 100% Error Max/Min
1 grado apertura
1 1
(*) Downstream the dissipating plate
Pipe press.drop coeff.
Upstream pipe xin / KvIn 0,00 [--]/[m3/h]
Downstream pipe xout/KvOut 0,00 [--]/[m3/h] 1 0,1
Upstream reservoir level P1 172,50 [m]
Downstream reservoir level P2 170,80 [m]

Valve pressure drop (valve 100% open) 0

Pressure drop coeff. (100% open) x 4,36 [---]


Flow coefficient (100% open) Kvs 12139 [m3/h]
Pressure drop (100% open) DP100% 1,70 1,70 [m] 0
Cavitation risk
Flow rate
Dissipating plate (optional) K,p 0 Case A
Pressure drop (diss.plate) DP,p 0,00 0,00 [m] Case B
0 0,01
Valve installation position 1 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
Outlet jet vel. 4,69 4,69 [m/s]
Valve opening degree [%] Valve opening degree [%]
Axial thrust max 8,39,E+05 [N]
(+ flow direction) min 8,37,E+05 [N] Pressure
Note Air intake Case B
1,0 Case A
Air intake 2,00 No 0,9

Pressure air intake [m]


Cavitation value s = Pout / (DP + v^2/2g) 0,8
xin
Pressure drop . DP = x v^2/2g 0,7
Pressure [mwh]; flow velocity [m/s] 0,6
0,5
0,4
Flow rate@100% opening 1,390 m3/s 0,3
0,2 73,8
xout Max emitted sound power 73,8 dB(A) 0,1 0,0
Actual noise level depends upon e.g. piping, distance 0,0
from the valve, presence of other noise source 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
Standard IEC 534-8-4 Valve opening degree [%]