You are on page 1of 11
eas . JIRUI ELECTRONICS TECHNOLOGY PTE LTD 232 Woodlands Industial Park ES Woodlands Bichub, $757298. Tel: (65) 6908 8918 Fax: (65) 6908 8919 Company UEN & GST Register No: 201538160R Tirui Electronics Technology Pte Lid Page No. [I ol Tee See Yau Date | 24 January 2022 IR-WPS-02 Revision No. 0 ‘Supporting PQR No. TR-PQR-02 Revision No. 0 [Welding Process (es) ‘GTAW (Autogenous) Type (s) ‘Automatic [Other (s) Not Applicable Q [Joint Design Square But Ts sss aaa aes Bevel Angle @) 00 v th [Groove Angle @) 0.0) x Root Face (mm) 00) aS Diameter [Root Spacing (mm) No Gap Backing No SIS Root Spacing ~ Backing Material (Type) Noi Applicable Groove Design of Test Coupon BASE METALS (QW-403) P-No (9). [Group No. 8 1 to e T ‘OR eae eon ASTM Az snes Deed wo | ASTM oes Caled Nambering System No.) 330403 to Se OR [Chemical Raye Not Applicable to ‘Not Applicable Mechanfeat Properties Not Applicable to Not Applicable [ase Meta [Groove | 150 10 422 (005971001667 [Fillet Not Applicable 50.8 t0 152.40 ( 2.00" to 6.00") max. [Not Applicable Other FILLER METALS (QW-404) POSITIONS (QW-405) Not Applicable Position 6) of Groove 36 [Welding Progression Uphill and Downhill Position (6) of Fillet Not Applicable [Other © ‘Not Applicable Form No. : WIPQRIIBEIZOI6- Revd ‘Job No. 99715 Report No. ‘SO9TTS- 5008 se 4 ¢ JIRUI ELECTRONICS TECHNOLOGY PTE LTD 252 Woodlands Industrial Park ES Woodlands Bichub. S757288. Tek (65) 6908 8918 Fax: (65) 6908 $919 Company LEN & GST Register No: 201538169R merce (Organization Tirui Eleetronies Technology Pte Led Page No. [2 of By Lee See Yau Date | 24 January 202: [WPS No. TR-WPS-02, Revision No. 0 [Supporting PQR No. IR-PQROD Revision No. 0 PREHEAT (QW-406) [Start Temperatore CO) ‘an Bo Interpass Temperature CQ [ma Not Applicable Preheat Maintenance ‘Not Applicable [Other (5) Not Applicable POST WELD HEAT TREATMENT (QW-407) Temperature Range CO) Not Applicable 10 Not Applicable [Time Range (hrs) ‘Not Applicable to Not Applicable [Other (=) Not Applicable ‘GAS (QW-408) ‘Composition Gas) Mixture (%) Flow Rate (LPM) [Shielding ‘Argon 99,999 (min.) 15.010 25.0 [Trailing Not Applicable Not Applicable Not Applicable Backing Argon 99.999 (min) 7.0 1025.0 (Other (s) Pre & Post Purging with Argon Gas Each For 30 Seconds Each (min) TECHNIQUE (QW-410) String or Weave Bead String [Orifice, Nozzle or Gas Cup Size Not Applicable Initial and Interpass Cleaning Brushing, [Method of Back Gouging Not Applicable Multiple or Single Pass (Per Side) Single Muitiple or Single Electrodes Single Peening Not Applicable [Other (9) Pulsing Current ‘Not Applicable ELECTRICAL CHARACTERISTICS (QW-409) Not Applicable wat] resin [rmicoven| acxcwrme [rou] FR] PCR ] moor | ratagew | consign el tan” [ene cmps]Ramzecamps | acroe | PHS | PaBE | to Tine ee) Prepared Byx, Approved By ( a catego Ay si act (Lee See Yau) ~~ fectronic Technology Pte Ltd) oe 4 ¢ JIRUI ELECTRONICS TECHNOLOGY PTE LTD 232 Woodlands Industral Park ES Woodlauds Bizhab, $757298, Tel: (65) 6908 8918 Fax: (65) 6908 8919 ‘Company UEN & GST Register No: 201538109R Jirui Electronics Technology Pte Lid Page No.] 1 of3 y Tee See Vau Date | 24 January 2022 POR No. TR-PQR-02 Revision No. 0 Welding Process (es) GTAW (Autogenous) Type (9) Automatic TOINTS (QW) NJoint Design Square Butt ewig Bevel Angle () 0.0 st aera ve [Groove Angle () 0.0 x ; [Root Spacing (mm) No Gap [Backing No SE Root Spacing x [Backing Material (Typo) Not Applicable Groove Design of Fest Coupon BASE METALS (QW-W05) Material Specification) [TypeGrde@] ASTM A269 | TP304L | to | ASIMA29 | IP30IL Untied Numbering System No () 30403 o 30803 PNo.) [Group No.6) 3 1 o. 3 7 [Chemical Analysis Not Applicable to ‘Nat Applicable [Mechanical Properties Not Applicable ©. ‘Not Applicable Thickness of Text Coupon, mim Gc 2.11 (0.083) to 2.11 (0.083) [Diamcer of Test Co 101-60 4.00) [Maximum Pasy Thickness mm (nc) Not Applicable [Other (9): Heat No (9). 3655363 to | 3650363 FILLER METALS (QW-404) Not Applicable POSITION (QW-405) Position @) 3G Weld Progression Uphill and Downhill Other G) Not Applicable PREREAT (QW-406) tart/ Preheat Temperature 25.0 Interpass Temperature CO) [max Not Applicable Other @ Not Applicable POSTWELD HEAT TREATMENT (OW-107) Holding Temperature CO) ‘Not Applicable Holding Time (hrs) Not Applicable (Other (9) Not Applicable Fora No: W/PQRIISITI016- Resa Job No. 99715 Report No. S99715- S007 se 4 ¢ JIRUI ELECTRONICS TECHNOLOGY PTE LTD 232 Woodlands Indusral Park ES Woodlaads Bichub, $737298, Tel: (68) 6808 8918 Fas: (65) 6908 8919 ‘Company VEN & GST Register No: 201538109R mere IR-PQR-02 [Revision No. 0 GAS (QW-408) Gase (es) Mixture (%) Flow Rate (LPM) TECHNIQUE (QW-410) wait Trnicuneat] wc coren [OT] ent rae Jy tor | Prtspeed | Dowa Stone ave] Prem) tse campo] Ranger) | pM | Nsey [BCR Pubes] yy] ture | Mamet Form No. WIPORI TB016- Revd ‘Job No. 99175 Report No, S9971S-S007 4 ¢ JIRUI ELECTRONICS TECHNOLOGY PTE LTD 232 Woodlands Industral Park ES Woodlands Bichub, 8787298, Tek: (65) 6908 8918. Fax: (65) 6508 8919 Company UEN & GST Register No: 201538169R anerre Jirui Electronics Technology Pte Ltd Page No.] 3.0f3 Lee See Yau Date | 24 January 2022 TR-POROD Revision No. 0 ‘VISUAL EXAMINATION Please refer to Report No. ‘Not Applicable Results Satisfactory [Remarks Not Applicable RADIOGRAPHY EXAMINATION _ [Please refer to Report No. '$99715- 4002 Results Satisfactory Remarks [Not Applicable IQUID PENETRANT INSPECTION (LPI[Please refer to Report No. ‘SB9715 - 4005 Ike Satisfacto Remarks Not Applicable ESTRUCTIVE TESTS TENSILE TEST (QW-150) Please Refer to Report N 'SHOT1S - 106 Specimen No] With oom) | Ticks (om) [Area em) imate Total Lad A) | Uitimate Unit Stes OPa) | Type of Faure & Location Ti | 90s [201 | 3835 23.05 601 Ductile | Weld Metal | 1902 [1.94 [36.90 2.4 600 Ductile | Weld Metal GUIDED BEND TEST (QW-160) __ [Please Refer to Report No. 99715 - 1002 Seecimene] Type Reull Fr Face factory F2_| Face ‘Satisfactory No Defect Was Observed RI] Root Satisfactory ‘No Defect Was Observed R2_[ Root Satisfactory No Defect Was Observed ing Operator's Name Lee Chin Hoe [Fin No. FISXXXXGL [Tests Conducted By Professional Testing Services Pte, Lid We certify thatthe statements Tn this record are correct and thatthe tests welds were prepared, welded, and tested In laccordance with the requirements of Section IX of the ASME Boiler and Pressure Vessel Code 2021 [Organization Professional Testing Services Pte. Li [Certified By ee See Yau Date 2a January 2022 Prepared By, ‘Approved By (Lee See Yau) (Jirui Electronics Technology Pte Ltd) Form Nox: WIFORIISTIZ016- Rev.0 JobNo. 99715 ReportNo. S99715-5007 % ¢ JIRUI ELECTRONICS TECHNOLOGY PTE LTD 232 Woodlands Industrial ask ES Woodlands Bich, $757298, ‘el: (65) 6908 8918 Fax (65) 6908 $919 ‘Company UEN & GST Register No: 201538169R merce WELDING OPERATOR PERFORMANCE QUALIFICATION (WOPQ) TEST according ASME INTORT [Welder's Name+ Lee Chin Hoe Identification No. FISXXXX3L. Identification of WPS: IR-WPS-02 Revision No. 0 Material Specification (9): ASTM A269 to ‘ASTM A269 [TyperGrade TP30aL to TP30aL. [UNS No. of Base Metal 330003 to '$30803 TESTING VARIABLES AND QUALIFICATION LIMITS aa] Variables ‘Actual Values Range Qualified [Welding Process es) GTAW (Autogenous) GTAW (Autozenous) ‘Automatic ‘Automatic : Without Backing Without Backing [Diameter of Pipe inches (mm) + 400(101.6) 2.87 (73.0) min. Pw 3 Sor Approved Equivalent lo Base Metal P-Number = 8 Bor Approved Equivalent Filer Metal or Electrode Speciation fy (FAMIaf Onl) Fier Metal or Fecrade Clasieation an Oi ber) Not Applicable ot Applicable [Consumable sere: rouet Form [Deposit Thiekness inches (am) = (0.083 2.11) 0.166 (4.22) man. 3G 56, Up& Down Up & Down Type of Fuel Gas: Not Applicable Not Applicable as Bucking (% Composition): Ar(99.999%) Ar(99.999%0 min) Transfer Mode = ‘Nat Applicable Not Applicable [Current Type oF Polarity DC-EN DC-EN {sual Examination of Completed Weld (QW-2024) Satisfactory Report No.: Not Applicable [Votumetic Examination Results (QW-191) = Satisfactory Report No. S99715 - 4002 Flom Eyaluated By: Roslan of Professional Testing Services Pte Lid [Welding Supervised By Lee See Yau cone tha the statements ‘of Seton 1X ofthe ASME Boiler and Pressure Vessel Code 2021 [Name of Organization Issuing Certca this eco and ha the est coupons wore prepared, welded, and ested in ascordance with he vequiremen Professional Testing Services Pte. Lid, Certified by Lee See Yau AWS-CWI Ceriication Number: 13101601 Date: 2a January 2025, (Lee See Yau) PORISII2016- Revd ‘Job No. 99715 Report No. S9971S- 5009 Form Novi wn, LZ Professional Testing Services Pte Ltd SS Pre cieci 32 Kian Teck Road, Singapore 628779. JASNA eae Tol:6778 1271 Fax: 6690 3920 Email quotations@plspicom 7S SSAC SINGLAS Wob Site: htip:tivww.ptspl.com Co. Reg No.: 00774/1985-K timteen RADIOGRAPHIC TEST REPORT Page 1 of 1 Laboratory Testo. : S 99715 ~ 4002 Report Dato; 21 January 2022 Customer Jirui Electronies Technology Pte Lid Date Tested — 20 January 2022 232 Woodlands Industrial Park ES, Date Received: 20 January 2022 ‘Woodlands Bizhub, PTS Rot 00-J15-B Singapore 757298 PO Order No. - Your Ret = Site Location PTS Laboratory Subject (as received) One (01) welded stainless steel pipe (Size: OD. 4", Thickness: 2.1 Imm) test sample, marked: WPS No.: JR-WPS-02, Process: Orbital GTAW (Autogenous), Position: 5G (Uphill and Downhill), Welding Operator's Name: Lee Chin Hoe, Welders FIN No.: FI3XXXX3L, Material Grade: ASTM A269 TP304L, for Radiographic Inspection Test (RT). ‘Technique Method Dwsl-13 Flim Type | Kodak MX125 - Class | Single Load Procedure No. PTS-ASMENDT-OO1 Rev. 1 Size | 10.4 | Quantity | 4 ‘Acceptance Criteria ‘ASME SEC IX -2019 Pb Sereen | 0.125mm | Density XRay__[Sensitiviy) Wire #5 (020mm) ai Type FFD | 609.6mm XReyiky OK. 3mA Designation FoD | _605.4%mm Focal Size ‘rm [OI Placement (OF 1m Fim Identification Position | 0D | _W.T+Reinforcoment | Interpretation | Accepted | Rejected Ca Zita [NON [7 7 [NbN im NDN v 3 —— NDN 7 [_ PCN T FOSLANE: SARIMIN ‘werd. or/PCN Conducted By Interpreted BY = Ri Sarinin) Approved By + Ray NDT Level NoTLeel + PCMag} Nbr Lee! + PCL evsfh Date : Date +21 January 2022 Date + 21 NeHubigpaoae: AS ARCSTRIKE KT TRANSVERSE CRACK BT-BURN THROUGH LACK OF INTER-RUN FUSION eee eee EC- ELONGATED CAVITIES SMG - ORINDING MARK LLP INCOMPLETE ROOT PENETRATION ER - EXCESSIVE REINFORCEMENT SRC ROOT CONCAVITIY P -GAS PORE LR LACK OF ROOT FUSION SSP SPATTER IN- SLAG INCLUSION LS LACK OF SIDE FUSION SU - SURFACE UNDERCUT IT TUNGSTEN INCLUSION NDN-NODISCONTINUITY NOTED SNP EXCESS PENETRATION BEAD KC-CRATER CRACK, G - POROSITY Sin LAL neareengel KE-EDOE CRACK RU -ROOT UNDERCUT RECOMMENDED LONGITUDINAL CRACK SED- EXCESSIVE DRESSING WHE WORMHOLE Professional Testing Services Pte Ltd 32 Kian Teck Road, Singapore 628779, Kix Tel: 678.1271 Fax: 6680 3320 Email: quotations@ptspl.com SAC-SINGLAS Web Site: http:tiwww.ptspl.com Co. Reg No.: 00774/1985-K pacar LIQUID PENETRANT TEST REPORT Pago 1 of 2 Laboratory TestNo. : S 99715 ~ 4005 Report Date 21 January 2 Customer Jirui Electronics Technology Pte Lid Date Tested 21 January 2022 232 Woodlands Industrial Park E5, Date Received = 20 January 2 Woodlands Bizhub, PTS Ret 00 - 15-8, Singapore 757298 PO/ Order No. - Your Ref a Site Location PTS Laboratory ‘Subject (as received) : ‘One (01) welded stainless steel pipe (Size: OD. 4", Thickness: 2.1 1mm) test sample, marked: WPS No.: JR-WPS-02, Process: Orbital GTAW (Autogenous), Position: 5G (Uphill and Downhill), Welding Operator's Name: Lee Chin Hoe, Welder’s FIN No.: FI3XXXX3L, Material Grade: ASTM A269 TP304L, for Liquid Penetrant Inspection (LPN. Test Method Visible Dye Sohvent Removable Method Procedure No. DDT-004 Rev. 6 ‘Acceptance Criteria SECAX- 2019 es (Test Temperature Ambient Tempera Surface Preparation Cleaned By Solvent Light Source ‘White Light Light Source Model/Serial Nox] —__LF-900, PTS-WL-OL [ Light meter Light intensity Model Lutron ‘White Light intensity |_ Min 1076 Lux 1650 Lux Serial No. (Waas07 Black Light intensity | in 1000 pen 7 Chemical Details Brand Code No. BatchNo. _[Ghemical Application] Expiry Date Penetrant Andeox ove 231975899) Spraying 06122 Remover Ardrox PRS 200616-1 | Sprasing & Wiping 0623 Developer Andeox NOL C23203909% Spraying 1022 Duell Time 15 Mins [| Biying Time 5 Mins Developing Time TO Mins Purpose of napection : To dotct the presence of any surface discontinuities in the test sample ‘Area Inspected 100% on the weld and HAZ ofthe est sample panes indication was observed on the examined surfaces of test sample(s) atthe time of inspection esut The tes result was ACCEPTED according to the acceptance criteria TestConductes 8y —: Ahmsam Bin Rasman (NDT Level 1) Test Witnessed By = Test Approved 8y + fun Bin Baharudin (PCN Level tt Remarks e Approved 8 Infun in Baharwin ‘NDT Deparment Professional Testing Services Pte Ltd 82 Kian Teck Road, Singapore 628779. Frccrecited teboratory Tel: 6778 1271 Fax: 6690 3320 Email: quotations@ptspl.com ZS SACSINGLAS Web Site: htipmacptsplcom Co, Reg No.: O0774/1985-K ES er} LIQUID PENETRANT TEST REPORT Page 2of2 Laboratory Test No, > S 99715 ~ 4005 Report Date 21 January 2022 Photographs), Documentation of Test Sample(s) Approved 8 Irfan Bia Baharudin ‘NDT Deseret aon, Professional Testing Services Pte Ltd 32 Kian Teck Road, Singapore 628779. toboratory Tol 6778 1271 Fax: 6690 3320 Email: quotations@ptspl.com SAC*SINGLAS Web Site: http:iwww.ptspl.com Co. Reg No.: 00774/1985-K TEST REPORT Laboratory Test No. ; S 99715 - 1002 Roport Date: 25 January 2022 Customer + Jirui Electronics Technology Pte Ltd Date Tested: 24 January 2022 232 Woodlands Industrial Park ES Date Received: 20 January 2022 Woodlands Bizhub PTS Ret 7 00 -J15-B ‘Singapore 757298 PO / Order No, Reference Code: ASME IX-2019 Your Ref tHe Subject (as received) : One welded stainless steel tube (Size: OD 4” x 2.11mm WT, Material: ASTM A269 TP304L) test sample, marked: WPS Noz: JR-WPS-02, Process: Orbital GTAW (Autogenous), Position: 5G (Uphill and Downhill), Welder Name: Lee Chin Hoe, FIN No.: FI3XXXX3L, for Welding Procedure Qualification Test. Test Method: ASME IX-2019 Test Temperature; *21°C Tensile Test: Reduced Section Transverse Weld Tensile Test Specimen Number Tr = T2 ‘Measured Diameter ~ = = = [Measured Thickness om [ 2.01 = 194 Measured Width = 19.08 = 19.02 Effective Arca om 38.35 = 36.90, Yield Load ow = = = Yield Stress © wan = = Fi (Ultimate Tensile Load on 23.03 22.14 [Ultimate Tensile Stess aan 601 = 600 (Gauge Length oo s S 7 Elongation oo = 7 = Reduction of Area ” = ns 7 Location of Faire = Broke at Weld Metal [ype of Fare Ductile Failure = Ductite Failure = Tost Conducted By ‘Damien Looi Engineer In Charged: Damien Looi Test Witnessed By Remarks Approved Signatory [Kew ect Department aot, Professional Testing Services Pte Ltd PSS 22 Kian Tek Road, Singapore 628779. jaG=MRA Tei. 6778 1271 Fax: 6660 3820 Ema: quotalons@plsplcom Za ‘Web Ste: ntpyamw.ptspLeom Go, Reg No: 00774/1985.K MES ines TEST REPORT Page 2 of2 Laboraton Testo. ; $ 99715 - 1002 Ropor Dato; 25 anvary 2022 Customer Jin Electonics Technology te Lid Date Tested =; 24 January 2022 232 Woodlands industrial Prk E5 Date Received; 20 January 2022 Woodlands Bizhub Pisret —; OO -JISB Singapore 757298 PO! Order No, Reference Code: ASME IX-2019 Your Ref a Subject (as receivea) =~ (One welded stainless steel tube (Size: OD 4" x 2.11mm WT, Material: ASTM A269 TP304L) test sample, marked: WPS No.: JR-WPS-02, Process: Orbital GTAW (Autogenous), Position: 5G (Uphill and Downhill), Welder Name: Lee Chin Hoe, FIN No.: FISXXXX3L, for Welding Procedure Qualification Test Test Method: ASMEIX-2019 Bond Test Test Temperature: 21°C Test Specimen Width =: «19mm Bend Angle etelan ite Test Specimen Thickness : 2.1 mm Former Diameter, : = 8 mm [Specimen No. | Type of Bend | Result Remarks FL Face Bend | Accepted No Defect Was Observed RI Root Bend | Accepted No Defeet Was Observed F2 Face Bend | Accepted No Defect Was Observed R2 Root Bend | Accepted No Defect Was Observed Test Conducted By: Nor Hezti Engineer In Charged : Damien Looi Tost Witnessed By; Remarks Seto Mechdnical Department

You might also like