VRF OUTDOOR UNITS

TECHNICAL CATALOG New Release Form FAN-2209 201709

INVERTER-DRIVEN
MULTI-SPLIT SYSTEM HEAT RECOVERY
AIR CONDITIONERS

Models:
< 3~, 460V/60Hz > < 3~/N, 380V/60Hz > < 3~, 220V/60Hz >
< Base Unit > < Base Unit > < Base Unit >
JTOR080VPEUBS1 JTOR080VPEFBS1 JTOR080VPERBS1
JTOR100VPEUBS1 JTOR100VPEFBS1 JTOR100VPERBS1
JTOR120VPEUBS1 JTOR120VPEFBS1 JTOR120VPERBS1
JTOR140VPEUBS1 JTOR140VPEFBS1 JTOR140VPERBS1
JTOR160VPEUBS1 JTOR160VPEFBS1 JTOR160VPERBS1
JTOR180VPEUBS1 JTOR180VPEFBS1 JTOR180VPERBS1
JTOR200VPEUBS1 JTOR200VPEFBS1 JTOR200VPERBS1
JTOR220VPEUBS1 JTOR220VPEFBS1 JTOR220VPERBS1
JTOR240VPEUBS1 JTOR240VPEFBS1 JTOR240VPERBS1

< Combination Unit > < Combination Unit > < Combination Unit >
JTOR260VAEUBS1 JTOR260VAEFBS1 JTOR260VAERBS1
JTOR280VAEUBS1 JTOR280VAEFBS1 JTOR280VAERBS1
JTOR300VAEUBS1 JTOR300VAEFBS1 JTOR300VAERBS1
JTOR320VAEUBS1 JTOR320VAEFBS1 JTOR320VAERBS1
JTOR340VAEUBS1 JTOR340VAEFBS1 JTOR340VAERBS1
JTOR360VAEUBS1 JTOR360VAEFBS1 JTOR360VAERBS1
JTOR380VAEUBS1 JTOR380VAEFBS1 JTOR380VAERBS1
JTOR400VAEUBS1 JTOR400VAEFBS1 JTOR400VAERBS1
JTOR420VAEUBS1 JTOR420VAEFBS1 JTOR420VAERBS1
JTOR440VAEUBS1 JTOR440VAEFBS1 JTOR440VAERBS1
JTOR460VAEUBS1 JTOR460VAEFBS1 JTOR460VAERBS1
JTOR480VAEUBS1 JTOR480VAEFBS1 JTOR480VAERBS1
JTOR500VAEUBS1 JTOR500VAEFBS1 JTOR500VAERBS1
JTOR520VAEUBS1 JTOR520VAEFBS1 JTOR520VAERBS1
JTOR540VAEUBS1 JTOR540VAEFBS1 JTOR540VAERBS1

Issue Date:
XX. Oct. 2017
IMPORTANT NOTICE

l YORK pursues a policy of continuing improvement in design and performance of products.


The right is therefore reserved to vary specifications without notice.
l YORK cannot anticipate every possible circumstance that might involve a potential hazard.
l This heat recovery air conditioner is designed for standard air conditioning only. Do not use this heat
recovery air conditioner for other purpose such as drying clothes, refrigerating foods or for any other
cooling or heating process.
l Do not install the unit in the following places. It may cause a fire, deformation, corrosion or failure.
* Places where oil (including machinery oil).
* Places where a lot of sulfide gas drifts such as in hot spring.
* Places where inflammable gas may generate or flow.
* Places where strong salty wind blows such as coast regions.
* Places with an atmosphere of acidity or alkalinity.
l Do not install the unit in the place where silicon gas drifts. If the silicon gas attaches to the surface of heat
exchanger, the fin surface repels water. As a result, drain water splashes outside of the drain pan and
splashed water runs inside of electrical box. In the end, water leakage or electrical devices failure may
occur.
l Pay attention to the following points when the unit is installed in a hospital or other facilities where
electromagnetic wave generates from medical equipment.
* Do not install the unit in the place where the electromagnetic wave is directly radiated to the electrical
box, controller cable or wired controller.
* Install the unit at least 3 meters away from electromagnetic wave such as a radio.
l Do not install the unit in the place where the breeze directly catches the animals and plants. It could
adversely affect the animals and plants.
l We strongly suggest to select the units with considering performance deterioration, as well as servicing,
maintenance and periodic electrical parts replacement if install the units to the altitude above 2,000m. We
also would like to request announcement of the fact to dealers.
l The installer and system specialist shall secure against leakage according to local regulations or
standards. The following standards may be applicable, if local regulations are not available.
International Organization for Standardization, ISO5149 or European Standard, EN378 or Japan Standard,
KHKS0010.
l No part of this manual may be reproduced without written permission.
l It is assumed that this heat recovery air conditioner will be operated and serviced by English speaking
people.
If this is not the case, the customer should be add safety, caution and operating signs in the native
language.
l If you have any questions, contact your distributor or dealer of YORK.
l This manual gives a common description and information for this heat recovery air conditioner which you
operate as well for other models.

FAN-2209 201709 i
l This heat recovery air conditioner has been designed for the following temperatures. Operate the heat
recovery air conditioner within this range.
l This system can provide Heat Recovery System.

Temperature (°C)
Cooling and Heating Operation
Cooling Operation Heating Operation
Cooling Heating
Indoor Air Inlet
15 to 23°C WB 15 to 27°C DB 15 to 23°C WB 15 to 27°C DB
Temperature

-5 to 24°C DB
-5 to 48°C DB
-6 to 15°C WB
Outdoor Air Inlet
With Low Ambient Setting* -20 to 15°C WB With Low Ambient Setting*
Temperature
-10 to 24°C DB
-10 to 48°C DB
-11 to 15°C WB
DB: Dry Bulb, WB: Wet Bulb

(*) NOTES:
1. Cooling operation at maximum 48°C DB should be available only if the outdoor air inlet temperature
increase temporarily according to the installation condition.
2. If install the units to the place where exceed ambient temperature 48°C DB continuously, the combination
ratio must be lower 130% and not to operate all of the indoor unit simultaneously.
3. The cooling capacity is deteriorated at high ambient temperature. Select the larger capacity outdoor unit
than compatible building heat load.
4. The appropriate amount (100%) of refrigerant must be charged. Excessive charging of refrigerant is
forbidden.
5. It must be avoided to install the units where affected by direct sunlight reflection and short circuit. There may
be the possibility to activate protection control and alarm system if install the units to inappropriate place.
Also the life time of the products and parts must be considerably shortened.
6. Periodic maintenance (1/certain month) must be applied to the heat exchanger fin to avoid adhesion of dirt
and clogging of sand to the outdoor unit heat exchanger.

* In case cooling operation or simultaneous operation under the inlet air temperature -5°C or lower the conditions
below must be considered at the time of installation.
● Make sure to apply Snow Protection Hood (Optional Parts).
● The minimum capacity of connectable indoor unit is 2.5HP.
● Set the function “Cooling Operation under Low Load Operation” (DSW6) from the outdoor unit
(If multiple outdoor units are connected in a system, set the function only for outdoor unit A).
● Make sure to apply new CH-Box (Optional Parts). The “Low Ambient Setting” is not available if the system is
connected with current CH unit.

This manual should be considered as a permanent part of the air conditioning equipment and should
remain with the air conditioning equipment.

ii FAN-2209 201709
SAFETY SUMMARY

< Signal Words >


● Signal words are used to identify levels of hazard seriousness.
Definitions for identifying hazard levels are provided below with their respective signal words.

DANGER : DANGER indicates a hazardous situation which, if not avoided,


will result in death or serious injury.

WARNING : WARNING indicates a hazardous situation which, if not avoided,


could result in death or serious injury.

CAUTION : CAUTION, used with the safety alert symbol, indicates a hazardous situation which,
if not avoided, could result in minor or moderate injury.

NOTICE : NOTICE is used to address practices not related to personal injury.

NOTE : NOTE is useful information for operation and/or maintenance.

FAN-2209 201709 iii


SAFETY SUMMARY

DANGER
● Do not perform installation work, refrigerant piping work, drain pump, drain piping and electrical wiring
connection without referring to our installation manual. If the instructions are not followed, it may result in
a water leakage, electric shock or a fire.
● Use the specified non-flammable refrigerant (R410A) to the outdoor unit in the refrigerant cycle.
Do not charge material other than R410A into the unit such as hydrocarbon refrigerants (propane or etc.),
oxygen, flammable gases (acetylene or etc.) or poisonous gases when installing, maintaining and moving.
These flammables are extremely dangerous and may cause an explosion, a fire, and injury.
● Do not pour water into the indoor or outdoor unit. These products are equipped with electrical parts.
If poured, it will cause a serious electrical shock.
● Do not open the service cover or access panel for the indoor or outdoor units without turning OFF the main
power supply.
● Do not touch or adjust safety devices inside the indoor unit or outdoor units. If these devices are touched
or readjusted, it may cause a serious accident.
● Refrigerant leakage can cause difficulty with breathing due to insufficient air. Turn OFF the main switch,
extinguish any naked flames and contact your service contractor, if refrigerant leakage occurs.
● Make sure that the refrigerant leakage test should be performed.
Refrigerant (Fluorocarbon) for this unit is incombustible, non-toxic and odorless.
However if the refrigerant is leaked and is contacted with fire, toxic gas will generate.
Also because the fluorocarbon is heavier than air, the floor surface will be filled with it, which could cause
suffocation.
● The installer and system specialist shall secure safety against refrigerant leakage according to local
regulations or standards.
● Use an ELB (Earth Leakage Breaker).
In the event of fault, there is danger of an electric shock or a fire if it is not used.
● Do not install the outdoor unit where there is high level of oil mist, flammable gases, salty air or harmful
gases such as sulfur.
● For installation, firmly connect the refrigerant pipe before the compressor starts operating.
For maintenance, relocation and disposal, remove the refrigerant pipe after the compressor stops.
● Do not perform a short-circuit of the protection device such as a pressure switch when operating.
It may cause a fire and explosion.

iv FAN-2209 201709
SAFETY SUMMARY

WARNING
● Do not use any sprays such as insecticide, lacquer, hair spray or other flammable gases within
approximately one (1) meter from the system.
● If circuit breaker or fuse is often activated, stop the system and contact your service contractor.
● Check that the ground wire is securely connected. If the unit is not correctly grounded, it lead electric
shock. Do not connect the ground wiring to gas piping, water piping, lighting conductor or ground wiring
for telephone.
● Connect a fuse of specified capacity.
● Before performing any brazing work, check to ensure that there is no flammable material around.
When using refrigerant be sure to wear leather gloves to prevent cold injuries.
● Protect the wires, electrical parts, etc. from rats or other small animals.
If not protected, rats may gnaw at unprotected parts and which may lead to a fire.
● Fix the cables securely. External forces on the terminals could lead to a fire.
● Provide a sufficiently strong foundation. If not, the unit may fall down and it may lead to injuries.
● Do not install the unit in a place where oil, vapor, organic solvent and corrosive gas (ammonia, sulfur
compound and acid) may be present in quantities.
It may cause refrigerant leakage due to corrosion, electrical shock, deteriorated performance and
breakage.
● Perform electrical work according to Installation Manual and all the relevant regulation and standards.
If the instructions are not followed, an electrical shock and fire may occur due to insufficient capacity and
inadequate performance.
● Use specified cables between units and choose the cables correctly. If not, an electrical shock or fire may
occur.
● Ensure that the wiring terminals are tightened securely with the specified torques. If not, generating fire or
electrical shock at the terminal connection part may occur.

CAUTION
● Do not step or put any material on the product.
● Do not put any foreign material on the unit or inside the unit.
● Provide a strong and correct foundation so that;
a. The outdoor unit is not on an incline.
b. Abnormal sound dose not occur.
c. The outdoor unit will not fall down due to a strong wind or earthquake.

FAN-2209 201709 v
SAFETY SUMMARY

NOTICE
● Do not install the indoor unit, outdoor unit, remote control switch and cable within approximately 3 meters
from strong electromagnetic wave radiators such as medical equipment.
● Supply electrical power to the system to energize the oil heater for 12 hours before startup after a long
shutdown.
● Make sure that the outdoor unit is not covered with snow or ice, before operation.
● In some cases, the packaged air conditioner may not be operated normally under the following cases.
* In case that electrical power for the packaged air conditioner is supplied from the same power
transformer as the device*.
* In case that the power source wires for the device* and the packaged air conditioner are located close to
each other.
Device*: (Ex) Lift, container crane, rectifier for electric railway, inverter power device, arc furnace,
electric furnace, large-sized induction motor and large-sized switch.
It consumes a large quantity of electrical power.

Regarding the cases mentioned above, surge voltage may be inducted in the power supply wiring for the
packaged air conditioner due to a rapid change in power consumption of the device and an activation of
switch.
Therefore, check the field regulations and standards before performing electrical work in order to protect
the power supply for the packaged air conditioner.

NOTE
● It is recommended that the room will be ventilated every 3 to 4 hours.
● The heating capacity of the heat recovery unit is decreased according to the outdoor air temperature.
Therefore, it is recommended that auxiliary heating equipment be used in the field when the units is
installed in a low temperature region.

vi FAN-2209 201709
- CONTENTS -
< Technical Data >
1. Features...................................................................................................................................................... 1-5
2. General Data............................................................................................................................................... 1-35
2.1 Outdoor Units..................................................................................................................................... 1-35
2.2 CH-Box............................................................................................................................................... 1-43
3. Component Data......................................................................................................................................... 1-44
4. Dimensional Data........................................................................................................................................ 1-47
4.1 Outdoor Units..................................................................................................................................... 1-47
4.2 CH-Box............................................................................................................................................... 1-50
5. Structure..................................................................................................................................................... 1-53
5.1 Outdoor Units..................................................................................................................................... 1-53
5.2 CH-Box............................................................................................................................................... 1-57
6. Selection Data............................................................................................................................................. 1-60
6.1 Selection Guide.................................................................................................................................. 1-60
6.2 Capacity Characteristic Curve............................................................................................................ 1-67
6.3 Outdoor Unit Capacity According to Temperature Condition and Connected IDU Capacity Ratio
(Part Load Data)................................................................................................................................. 1-110
6.4 Correction Factor According to Piping Length.................................................................................... 1-110
6.5 Correction Factor According to Defrosting Operation......................................................................... 1-113
6.6 Correction Factor According to Altitude.............................................................................................. 1-114
7. Electrical Data............................................................................................................................................. 1-115
8. Sound Data................................................................................................................................................. 1-118
8.1 Outdoor Units..................................................................................................................................... 1-118
8.2 CH-Box............................................................................................................................................... 1-124
9. Center of Gravity......................................................................................................................................... 1-126
10. Working Range........................................................................................................................................... 1-127
11. Optional Accessories.................................................................................................................................. 1-129
11.1 Piping Connection Kit......................................................................................................................... 1-129
11.2 CH-Box............................................................................................................................................... 1-130
11.3 Multi-Kit.............................................................................................................................................. 1-131
11.4 Drain Boss.......................................................................................................................................... 1-132
11.5 Air Inlet Grille...................................................................................................................................... 1-133
11.6 Protection Net..................................................................................................................................... 1-134

FAN-2209 201709 vii


- CONTENTS -
< Technical Data >
12. Control System........................................................................................................................................... 1-135
12.1 Refrigeration Cycle............................................................................................................................. 1-135
12.1.1 Outdoor Units............................................................................................................................ 1-135
12.1.2 CH-Box..................................................................................................................................... 1-137
12.2 Control System................................................................................................................................... 1-140
12.3 Standard Operation Sequence........................................................................................................... 1-152
12.4 Safety and Control Device Setting..................................................................................................... 1-168
12.5 Electrical Wiring Diagram................................................................................................................... 1-169
12.5.1 Outdoor Units............................................................................................................................ 1-169
12.5.2 CH-Box..................................................................................................................................... 1-181
13. Miscellaneous Notes................................................................................................................................... 1-186
14. Standard Specifications.............................................................................................................................. 1-187
15. Caution on Refrigerant Leakage................................................................................................................. 1-188
15.1 Maximum Permissible Concentration of HFC Gas............................................................................. 1-188
15.2 Calculation of Refrigerant Concentration........................................................................................... 1-188

< Installation and Operation >


● Outdoor Units (FAN-2208 201709)............................................................................................................. 2-3
● Piping Connection Kit <3 pipes>: MC-NP20 - 30SX (P5417030)............................................................... 2-95
● Multi-Kit (Line Branch) <3 pipes>: MW-NP142 - 902X3 (P5416979).......................................................... 2-100
● Multi-Kit (Line Branch) <2 pipes>: MW-NP282 - 902A3 (P5416978).......................................................... 2-106
● Multi-Kit (Header Branch) <3 pipes>: JMH-NP280X (FAN-1593 201607 <P5416738>)............................ 2-111
● Multi-Kit (Header Branch) <2 pipes>: JMH-NP224A, 280A (FAN-1591 201607 <P5416736>).................. 2-115
● Drain Boss: DBS-TP10A (P5414717)......................................................................................................... 2-119
● Air Inlet Grille: PSN-TP20** (P5416988 - P5416991)................................................................................. 2-121
● Protection Net: PN-TP20** (P5416992 - P5416995).................................................................................. 2-133
● CH-Box <Single Branch Type> (FAN-2212 201711 <P5417023>)............................................................. 2-146
● CH-Box <Multiple Branch Type> (FAN-2213 201711 <P5417025>)........................................................... 2-173

< Appendix >


1. Cooling Capacity Part Load Data........................................................................................................A-2
2. Heating Capacity Part Load Data........................................................................................................A-74

viii FAN-2209 201709


Technical Data

FAN-2209 201709 1-1


1-2 FAN-2209 201709
- CONTENTS -

1. Features...................................................................................................................................................... 1-5
2. General Data............................................................................................................................................... 1-35
2.1 Outdoor Units..................................................................................................................................... 1-35
2.2 CH-Box............................................................................................................................................... 1-43
3. Component Data......................................................................................................................................... 1-44
4. Dimensional Data........................................................................................................................................ 1-47
4.1 Outdoor Units..................................................................................................................................... 1-47
4.2 CH-Box............................................................................................................................................... 1-50
5. Structure..................................................................................................................................................... 1-53
5.1 Outdoor Units..................................................................................................................................... 1-53
5.2 CH-Box............................................................................................................................................... 1-57
6. Selection Data............................................................................................................................................. 1-60
6.1 Selection Guide.................................................................................................................................. 1-60
6.2 Capacity Characteristic Curve............................................................................................................ 1-67
6.3 Outdoor Unit Capacity According to Temperature Condition and Connected IDU Capacity Ratio
(Part Load Data)................................................................................................................................. 1-110
6.4 Correction Factor According to Piping Length.................................................................................... 1-110
6.5 Correction Factor According to Defrosting Operation......................................................................... 1-113
6.6 Correction Factor According to Altitude.............................................................................................. 1-114
7. Electrical Data............................................................................................................................................. 1-115
8. Sound Data................................................................................................................................................. 1-118
8.1 Outdoor Units..................................................................................................................................... 1-118
8.2 CH-Box............................................................................................................................................... 1-124
9. Center of Gravity......................................................................................................................................... 1-126
10. Working Range........................................................................................................................................... 1-127
11. Optional Accessories.................................................................................................................................. 1-129
11.1 Piping Connection Kit......................................................................................................................... 1-129
11.2 CH-Box............................................................................................................................................... 1-130
11.3 Multi-Kit.............................................................................................................................................. 1-131
11.4 Drain Boss.......................................................................................................................................... 1-132
11.5 Air Inlet Grille...................................................................................................................................... 1-133
11.6 Protection Net..................................................................................................................................... 1-134

FAN-2209 201709 1-3


- CONTENTS -

12. Control System........................................................................................................................................... 1-135


12.1 Refrigeration Cycle............................................................................................................................. 1-135
12.1.1 Outdoor Units............................................................................................................................ 1-135
12.1.2 CH-Box..................................................................................................................................... 1-137
12.2 Control System................................................................................................................................... 1-140
12.3 Standard Operation Sequence........................................................................................................... 1-152
12.4 Safety and Control Device Setting..................................................................................................... 1-168
12.5 Electrical Wiring Diagram................................................................................................................... 1-169
12.5.1 Outdoor Units............................................................................................................................ 1-169
12.5.2 CH-Box..................................................................................................................................... 1-181
13. Miscellaneous Notes................................................................................................................................... 1-186
14. Standard Specifications.............................................................................................................................. 1-187
15. Caution on Refrigerant Leakage................................................................................................................. 1-188
15.1 Maximum Permissible Concentration of HFC Gas............................................................................. 1-188
15.2 Calculation of Refrigerant Concentration........................................................................................... 1-188

1-4 FAN-2209 201709


FEATURES

1. Features
Outdoor Unit
YORK proudly introduces the New Outdoor Unit series, the highly-efficient and reliable air-conditioning
system. Recently, increased numbers of buildings are requiring "Intelligent" facilities - communication
networks, office automation, and a comfortable environment. Particularly, comfortable space is required all
the day through the year in office buildings.
This multi-split system air conditioner can meet these requirements. The proven combination of the scroll
compressor and the inverter provides the best air conditioning for small/medium office buildings.

■ Wide Product Range of Outdoor Units


Space, structure and necessary functions, in line with evolution in building design, the requirements for air
conditioning have also diversified.
New Outdoor Unit series offers 9 module outdoor units, respectively.
Because the most suitable unit can be selected from a wide range of models, you can create a custom air
conditioning environment to satisfy your specific building conditions.

FAN-2209 201709 1-5


FEATURES

(1) Series Configuration


• Expand single module range

HP
Series
5 6 8 10 12 14 16 18 20 22 24 26 28
Current Model
- - ● ● ● ● ● ○ ○ ○ ○ ○ ○
[Heat Pump/Heat Recovery]
New Model
- - H H H H H H H H H I I
[Heat Recovery]
HP
Series
30 32 34 36 38 40 42 44 46 48 50 52 54
Current Model
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
[Heat Pump/Heat Recovery]
New Model
I I I I I I I I I I I I I
[Heat Recovery]
● Current Line-up (Single Module) ○ Current Line-up (Combination) - Not available
H New Line-up (Single Module) I New Line-up (Combination)

<ALL INVERTER Compressor Model (All Models)>


Current Model Inverter + Constant
New Model Inverter

<New CH-Box>
Single Multiple
Series
˂6HP 6.1HP - 10HP 4 Branch 8 Branch 12 Branch 16 Branch
Current Model
● ● - - - -
(CH Unit)
New Model
H H H H H H
(CH-Box)

● Current Line-up H New Line-up - Not available


NOTE:
Refer to the below figure for the interchangeability between Current CH Unit and New CH-Box.

Interchangeability between Current CH Unit and New CH-Boxes


(1) The product name has been changed to CH-Box for the new product
(2) New CH-Box and current CH Unit are compatible for the new outdoor units. However, only the
current CH-unit is compatible for the current outdoor unit.

4: Available
4
4
Current CH Unit Current VRF (Heat Recovery)
×: Not Available
×
4
4
New CH-Box New VRF (Heat Recovery)
4
4

(3) The current CH Unit and the new CH-Boxes can not be used in the same system together.
(4) The production of current CH Unit shall be discontinued, however, it will be supplied for servicing
and maintenance until further notice. Contact us if there are order request for the current CH Unit

1-6 FAN-2209 201709


FEATURES

Capacity Range (HP) 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54

JTOR080VPE(U,F,R)BS1
JTOR100VPE(U,F,R)BS1
JTOR120VPE(U,F,R)BS1

JTOR140VPE(U,F,R)BS1
Base Units JTOR160VPE(U,F,R)BS1
JTOR180VPE(U,F,R)BS1

JTOR200VPE(U,F,R)BS1
JTOR220VPE(U,F,R)BS1
JTOR240VPE(U,F,R)BS1

JTOR260VAE(U,F,R)BS1
JTOR280VAE(U,F,R)BS1
JTOR300VAE(U,F,R)BS1

JTOR320VAE(U,F,R)BS1
JTOR340VAE(U,F,R)BS1
JTOR360VAE(U,F,R)BS1

JTOR380VAE(U,F,R)BS1
Combination of
JTOR400VAE(U,F,R)BS1
Base Units
JTOR420VAE(U,F,R)BS1

JTOR440VAE(U,F,R)BS1

JTOR460VAE(U,F,R)BS1
JTOR480VAE(U,F,R)BS1

JTOR500VAE(U,F,R)BS1
JTOR520VAE(U,F,R)BS1
JTOR540VAE(U,F,R)BS1

FAN-2209 201709 1-7


FEATURES

System Configuration / Appearance

Heat Recovery System

Refrigerant Piping (3 Pipes)


Outdoor Unit
Transmission Line (H-LINK III)

Indoor Unit Refrigerant Piping (2 Pipes)


System /
Appearance CH-Box

Piping Connection Kit (3 Pipes) Refrigerant Piping (3 Pipes)

Optional
Optional Air Panel for Other
Indoor Unit + Remote Control + +
Cassette Type Optional Parts
Switch

NEW CH-Box

Optional Multi-Kit For Branch Connection of Indoor Units

Other Optional Parts


System Device Outdoor Unit + (Drain Boss, Air Inlet Grille, Protection Net and
Air Outlet Duct-Kit, etc.)

For Branch Connection of Outdoor Units


Piping Connection Kit Applicable for 26HP to 54HP Outdoor Unit

: Necessary Equipments for System


: Necessary Equipments depending on Usage Purpose

1-8 FAN-2209 201709


FEATURES

■ Line-Up
● Outdoor Unit
This outdoor unit series “JTOR***VPEUBS1”, “JTOR***VPERBS1” and “JTOR***VPEFBS1” can build
the capacity from 8 to 54HP by combining maximum 3 outdoor units from 8 to 24HP.

J T O R 080 V P E R B S 1
Version
Factory
S: Shimizu, Japan
Generation
Power Supply
U: 3~, 460V/60Hz
F: 3~/N, 380V/60Hz
R: 3~, 220V/60Hz
Refrigerant
E: R410A
Module and Combination
A: All Inverter Combination
P: All Inverter Module
Air Discharge
V: Vertical
Capacity
HP x 10 (Example: 080 = 8HP)
Application
R: Heat Recovery
Heat Source
O: Air Source
Market Position
T: Tier-1 Commercial VRF
Brand
J: York Brand

FAN-2209 201709 1-9


FEATURES

■ for 3~, 460V/60Hz


< Base Unit >
HP 8 10 12 14 16
Model JTOR080VPEUBS1 JTOR100VPEUBS1 JTOR120VPEUBS1 JTOR140VPEUBS1 JTOR160VPEUBS1

HP 18 20 22 24
Model JTOR180VPEUBS1 JTOR200VPEUBS1 JTOR220VPEUBS1 JTOR240VPEUBS1
< Combination of Base Units > T
HP 26 28 30 32 34
Model JTOR260VAEUBS1 JTOR280VAEUBS1 JTOR300VAEUBS1 JTOR320VAEUBS1 JTOR340VAEUBS1
JTOR120VPEUBS1 JTOR120VPEUBS1 JTOR120VPEUBS1 JTOR140VPEUBS1 JTOR160VPEUBS1
Combination
JTOR140VPEUBS1 JTOR160VPEUBS1 JTOR180VPEUBS1 JTOR180VPEUBS1 JTOR180VPEUBS1

HP 36 38 40 42 44
Model JTOR360VAEUBS1 JTOR380VAEUBS1 JTOR400VAEUBS1 JTOR420VAEUBS1 JTOR440VAEUBS1
JTOR180VPEUBS1 JTOR140VPEUBS1 JTOR180VPEUBS1 JTOR180VPEUBS1 JTOR220VPEUBS1
Combination
JTOR180VPEUBS1 JTOR240VPEUBS1 JTOR220VPEUBS1 JTOR240VPEUBS1 JTOR220VPEUBS1

HP 46 48 50 52 54
Model JTOR460VAEUBS1 JTOR480VAEUBS1 JTOR500VAEUBS1 JTOR520VAEUBS1 JTOR540VAEUBS1
JTOR220VPEUBS1 JTOR240VPEUBS1 JTOR140VPEUBS1 JTOR160VPEUBS1 JTOR180VPEUBS1
Combination JTOR240VPEUBS1 JTOR240VPEUBS1 JTOR180VPEUBS1 JTOR180VPEUBS1 JTOR180VPEUBS1
- - JTOR180VPEUBS1 JTOR180VPEUBS1 JTOR180VPEUBS1

■ for 3~/N, 380V/60Hz


< Base Unit >
HP 8 10 12 14 16
Model JTOR080VPEFBS1 JTOR100VPEFBS1 JTOR120VPEFBS1 JTOR140VPEFBS1 JTOR160VPEFBS1

HP 18 20 22 24
Model JTOR180VPEFBS1 JTOR200VPEFBS1 JTOR220VPEFBS1 JTOR240VPEFBS1
< Combination of Base Units > T
HP 26 28 30 32 34
Model JTOR260VAEFBS1 JTOR280VAEFBS1 JTOR300VAEFBS1 JTOR320VAEFBS1 JTOR340VAEFBS1
JTOR120VPEFBS1 JTOR120VPEFBS1 JTOR120VPEFBS1 JTOR140VPEFBS1 JTOR160VPEFBS1
Combination
JTOR140VPEFBS1 JTOR160VPEFBS1 JTOR180VPEFBS1 JTOR180VPEFBS1 JTOR180VPEFBS1

HP 36 38 40 42 44
Model JTOR360VAEFBS1 JTOR380VAEFBS1 JTOR400VAEFBS1 JTOR420VAEFBS1 JTOR440VAEFBS1
JTOR180VPEFBS1 JTOR140VPEFBS1 JTOR180VPEFBS1 JTOR180VPEFBS1 JTOR220VPEFBS1
Combination
JTOR180VPEFBS1 JTOR240VPEFBS1 JTOR220VPEFBS1 JTOR240VPEFBS1 JTOR220VPEFBS1

HP 46 48 50 52 54
Model JTOR460VAEFBS1 JTOR480VAEFBS1 JTOR500VAEFBS1 JTOR520VAEFBS1 JTOR540VAEFBS1
JTOR220VPEFBS1 JTOR240VPEFBS1 JTOR140VPEFBS1 JTOR160VPEFBS1 JTOR180VPEFBS1
Combination JTOR240VPEFBS1 JTOR240VPEFBS1 JTOR180VPEFBS1 JTOR180VPEFBS1 JTOR180VPEFBS1
- - JTOR180VPEFBS1 JTOR180VPEFBS1 JTOR180VPEFBS1

T: The outdoor unit from 26 to 54HP consists of the combination of 2 to 3 base units.
The combinations other than listed in above table is prohibited.
NOTE:
Refer to the “Caution about Outdoor Unit Installation”.

1-10 FAN-2209 201709


FEATURES

■ for 3~, 220V/60Hz


< Base Unit >
HP 8 10 12 14 16
Model JTOR080VPERBS1 JTOR100VPERBS1 JTOR120VPERBS1 JTOR140VPERBS1 JTOR160VPERBS1

HP 18 20 22 24
Model JTOR180VPERBS1 JTOR200VPERBS1 JTOR220VPERBS1 JTOR240VPERBS1
< Combination of Base Units > T
HP 26 28 30 32 34
Model JTOR260VAERBS1 JTOR280VAERBS1 JTOR300VAERBS1 JTOR320VAERBS1 JTOR340VAERBS1
JTOR120VPERBS1 JTOR120VPERBS1 JTOR120VPERBS1 JTOR140VPERBS1 JTOR160VPERBS1
Combination
JTOR140VPERBS1 JTOR160VPERBS1 JTOR180VPERBS1 JTOR180VPERBS1 JTOR180VPERBS1

HP 36 38 40 42 44
Model JTOR360VAERBS1 JTOR380VAERBS1 JTOR400VAERBS1 JTOR420VAERBS1 JTOR440VAERBS1
JTOR180VPERBS1 JTOR140VPERBS1 JTOR180VPERBS1 JTOR180VPERBS1 JTOR220VPERBS1
Combination
JTOR180VPERBS1 JTOR240VPERBS1 JTOR220VPERBS1 JTOR240VPERBS1 JTOR220VPERBS1

HP 46 48 50 52 54
Model JTOR460VAERBS1 JTOR480VAERBS1 JTOR500VAERBS1 JTOR520VAERBS1 JTOR540VAERBS1
JTOR220VPERBS1 JTOR240VPERBS1 JTOR140VPERBS1 JTOR160VPERBS1 JTOR180VPERBS1
Combination JTOR240VPERBS1 JTOR240VPERBS1 JTOR180VPERBS1 JTOR180VPERBS1 JTOR180VPERBS1
- - JTOR180VPERBS1 JTOR180VPERBS1 JTOR180VPERBS1

T: The outdoor unit from 26 to 54HP consists of the combination of 2 to 3 base units.
The combinations other than listed in above table is prohibited.
NOTE:
Refer to the “Caution about Outdoor Unit Installation”.

FAN-2209 201709 1-11


FEATURES

< Base Unit >


8HP - 12HP 14HP - 18HP 20HP - 24HP
Outer Dimension: Outer Dimension: Outer Dimension:
W950 x D765 x H1675 mm W1210 x D765 x H1675 mm W1600 x D765 x H1675 mm

< Combination of Base Units >


26HP - 30HP 32HP - 36HP 38HP - 42HP

44HP - 48HP 50HP - 54HP

1-12 FAN-2209 201709


FEATURES

● Piping Connection Kit


MC - NP 21 SX
Applicable System
SX: for Heat Recovery System (3 Pipes)
Corresponding Outdoor Units Capacity
21: 26 - 48HP
30: 50 - 54HP

Refrigerant Type
NP: R410A
Unit Type
MC: Multi Connection Kit for Outdoor Units

Applicable Outdoor Unit


Item Connectivity Model Remarks
HP
Number
for Low Pressure Gas: 1
26 - 48 2 MC-NP21SX for High/Low Pressure Gas: 1
Piping for Liquid: 1
Connection
Kit for Low Pressure Gas: 2
50 - 54 3 MC-NP30SX for High/Low Pressure Gas: 2
for Liquid: 2
NOTE:
The old model (MC-TTX1) is not available.

● Multi-Kit
MW - NP 14 2 X 3
Type of Generation
Applicable System
X: for 3 Pipes
A: for 2 Pipes
No. of Branches
Corresponding Outdoor Units Capacity
14: 5HP 56: 18, 20HP
28: 6 - 10HP 69: 22, 24HP
45: 12 - 16HP 90: 26 - 54HP
Refrigerant Type
NP: R410A
Unit Type
MW: Line Branch Multi-Kit for Outdoor Units
MH: Header Branch Multi-Kit for Outdoor Units

FAN-2209 201709 1-13


FEATURES

< Line Branch >


First Branch
Outdoor Unit HP Model Remarks
5 MW-NP142X3
6 - 10 MW-NP282X3
12 - 16 MW-NP452X3
For 3 pipes
18, 20 MW-NP562X3
22, 24 MW-NP692X3
26 - 54 MW-NP902X3

Multi-Kit after First Branch


Diameter (mm)
Total Indoor Unit HP High/Low Pressure Model Remarks
Gas Pipe Liquid Pipe
Gas Pipe
<6 f15.88 f12.7 f9.52 MW-NP142X3
6 - 8.99 f19.05 f15.88 f9.52
MW-NP282X3
9 - 11.99 f22.2 f19.05 f9.52
12 - 15.99 f25.4 f22.2 f12.7
MW-NP452X3
16 - 17.99 f28.58 f22.2 f12.7 For 3 pipes
18 - 21.99 f28.58 f22.2 f15.88 MW-NP562X3
22 - 25.99 f28.58 f25.4 f15.88 MW-NP692X3
26 - 35.99 f31.75 f28.58 f19.05
MW-NP902X3
> 36 f38.1 f31.75 f19.05
<6 f15.88 f9.52
6 - 8.99 f19.05 f9.52 MW-NP282A3
9 - 11.99 f22.2 f9.52
12 - 15.99 f25.4 f12.7
- MW-NP452A3 For 2 pipes
16 - 17.99 f28.58 f12.7
18 - 25.99 f28.58 f15.88 MW-NP692A3
26 - 35.99 f31.75 f19.05
MW-NP902A3
> 36 f38.1 f19.05

< Header Branch >


Total Indoor Unit HP No. of Header Branches Model
5 - 10 8 JMH-NP288X
5-8 4 JMH-NP224A
5 - 10 8 JMH-NP288A

1-14 FAN-2209 201709


FEATURES

● CH-Box
<Single>
J CH - AP 160 SSX

Applicable System
SSX: for Heat Recovery System (3 Pipes System)
Maximum Connectable Indoor Unit Capacity (HP)
160: 6.0HP
280: 6.1HP - 10.0HP
Refrigerant Type
AP: R410A
Unit Type
CH: Cooling/Heating Change-Over Box
Brand
York Brand
Connectable Indoor Unit Number of Connectable
Model Branch
Total Capacity Indoor Unit(*1)
JCH-AP160SSX 1 6.0HP or less (Max. 16kW) 1-7
JCH-AP280SSX 1 6.1HP - 10.0HP (Max. 28kW) 1-8
( 1)
* When multiple indoor units are connected to the same CH-Box, they are controlled within
the same operation mode.

<Multiple>
J CH - AP 16 M SSX
Applicable System
SSX: for Heat Recovery System (3 Pipes System)
Multiple
Branch
04: 4 Branch
08: 8 Branch
12: 12 Branch
16: 16 Branch
Refrigerant Type
AP: R410A
Unit Type
CH: Cooling/Heating Change-Over Box
Brand
York Brand
Connectable Indoor Unit Number of Connectable
Model Branch
Total Capacity Indoor Unit per Branch(*2)
JCH-AP04MSSX 4 16.0HP or less (Max. 44.8kW) 1-6
JCH-AP08MSSX 8 30.0HP or less (Max. 85kW) 1-6
JCH-AP12MSSX 12 30.0HP or less (Max. 85kW) 1-6
JCH-AP16MSSX 16 30.0HP or less (Max. 85kW) 1-6
( 2)
* The indoor units connected to the same branch of the CH-Box are controlled within the
same operation mode.

FAN-2209 201709 1-15


FEATURES

<CH-Box>

<Single>

JCH-AP160SSX JCH-AP280SSX
Outer Dimension: W301 x D214 x H191 mm Outer Dimension: W301 x D214 x H191 mm

<Multiple>

JCH-AP04MSSX JCH-AP08MSSX
Outer Dimension: W303 x D352 x H260mm Outer Dimension: W543 x D352x H260 mm

JCH-AP12MSSX JCH-AP16MSSX
Outer Dimension: W783 x D352 x H260 mm Outer Dimension: W1,023 x 352 x H260 mm

1-16 FAN-2209 201709


FEATURES

Various Indoor Units and Combinations

The line-up of new YORK VRF series indoor units has been extended up to 7 types of indoor units to meet
various building requirements. (0.6HP through 10HP)

Nominal Capacity (HP)


Indoor Unit Type
0.6 0.8 1.0 1.3 1.5 1.8 2.0 2.3 2.5 3.0 3.3 4.0 5.0 6.0 8.0 10.0
In-the-Ceiling
4-Way Cassette
4-Way Cassette
Compact
2-Way Cassette
Wall
Floor Concealed
Ceiling
: Available

• The number of indoor units connectable to outdoor unit is as follows.


Comply with the following conditions when installing the unit.
• A maximum total capacity of 130% and a minimum total capacity of 50% against the nominal outdoor unit
capacity can be obtained by combination of the indoor units.

FAN-2209 201709 1-17


FEATURES

Able to Connect a Set of Outdoor Unit with up to 64 Indoor Units

Min. Capacity Recommended Range of Total Length between


Outdoor Unit Max. Number of
at Individual Number of Combination Each I.U. and
(HP) Connectable I.U.
Operation Connectable I.U. Capacity Expansion Valve Kit (*)
8 13 8
40m
10 16 10
12 19 10 60m
14 23 16 70m
16 26 16
80m
18 26 16
20 33 18
22 36 20 120m
24 40 26
26 43 26
28 47 32 50 to 130% *1 150m
30 0.6HP *3 50 32 (In case the
32 (1.6kW) 53 32 combination ratio
34 56 32 exceed 130%) *2 180m
36 59 32
38 64 38
40 64 38
42 64 38
44 64 38
46 64 38 200m
48 64 38
50 64 38
52 64 38
54 64 38
*1: There might be the possibility of insufficient capacity of 130% combination ratio if the capacity of combination ratio
of indoor units exceed 100% capacity of outdoor unit. Please refer to the technical catalog.
*2: Contact your distributer or dealer if the capacity of combination ratio exceed 130%.
The system configuration exceed standard combination ratio (130%) without consultation with distributer or dealer is
not acceptable. It may cause activation of alarm and operation failure.
*3: In case of setting low ambient temperature at cooling operation, the minimum capacity of connectable indoor unit
should be 2.5 HP.

NOTES:
1. The connectable indoor unit capacity ratio can be calculated as follows.
Connectable Indoor Unit Capacity Ratio = Total Indoor Unit Capacity / Total Outdoor Unit Capacity
2. For the system under which all the indoor units are supposed to operate simultaneously, the total indoor unit capacity
should be less than outdoor unit capacity. Otherwise, it may cause a decrease of operating performance and operating
limit in overload operation.
3. For the system under which all the indoor units are not supposed to operate simultaneously, the total indoor unit
capacity is available up to 130% against the outdoor unit capacity.
4. Maximum number of connectable indoor units differs depending on the model, capacity, environment and installation
place of connected indoor units. Refer to “Technical Catalog” for the selection.
5. When operating the outdoor unit in cold areas with temperatures of -10oC, or under the high heating load conditions,
the total indoor unit capacity should be less than 100% against the outdoor unit capacity and the total piping length
should be less than 300m.
6. The air flow volume for indoor units of 1.0HP or less is set higher than that for indoor units of 1.5HP or more. Make
sure to select appropriate indoor units when installing indoor units where cold draft may occur during heating operation.
If installing indoor units in such places, refer to the recommended number of connectable indoor units.
7. (*): For connecting Wall Type with the Expansion Valve Kit, the number of connectable indoor unit is limited according
to the total piping length between the expansion valve and the indoor unit. The total piping length must be less than
the length indicated in the table.
The load capacity per hour or the possibility of all indoor units simultaneous operation is unknown at the design stage,
the total capacity of combined indoor units should be not over 100% against the outdoor unit capacity.

1-18 FAN-2209 201709


FEATURES

High Efficiency and Energy Saving


(1) High EER/COP Design
The new SET FREE has achieved high EER/COP and considerable energy saving by improving the
performance of compressor and optimizing refrigerant cycle system.

(EER)
EER (COP)
COP
7.00 7.00

6.00 5.21 6.00 5.34 5.11


4.76 4.90 4.94
5.00 4.46 4.21 5.00
4.15
3.70 3.75 3.55 3.93 4.10 4.09 3.92 3.84
4.00 4.00 3.43
3.00 3.00
2.00 2.00
1.00 1.00
8 10 12 14 16 18 20 22 24 8 10 12 14 16 18 20 22 24
(HP) (HP)

NOTE:
The above values indicate the EER/COP per outdoor unit when it is combined with specified indoor
units.

Nominal Capacity and Efficiency

HP 8 10 12 14 16 18 20 22 24 26 28 30
Capacity 22.4 28.0 33.5 40.0 45.0 50.0 56.0 61.5 67.0 73.0 77.5 85.0
Cooling

(kW)

EER 5.21 4.76 4.90 4.15 4.46 4.21 3.70 3.75 3.55 4.49 4.71 4.39

Capacity 25.0 31.5 37.5 45.0 50.0 56.0 63.0 69.0 77.5 82.5 90.0 95.0
Heating

(kW)

COP 5.34 5.11 4.94 3.93 4.10 4.09 3.92 3.43 3.84 4.33 4.30 4.33

HP 32 34 36 38 40 42 44 46 48 50 52 54
Capacity 90.0 95.0 100.0 106.0 112.0 118.0 122.0 128.0 136.0 140.0 145.0 150.0
Cooling

(kW)

EER 4.18 4.32 4.21 3.79 3.92 3.77 3.79 3.66 3.54 4.19 4.28 4.21

Capacity 100.0 106.0 112.0 118.0 125.0 132.0 140.0 145.0 150.0 155.0 160.0 165.0
Heating

(kW)

COP 4.06 4.10 4.10 4.04 3.74 3.90 3.39 3.67 3.85 4.10 4.15 4.17

NOTES:
1. The cooling and heating performances are the value s when combined with our specified indoor units.
Cooling Operation Conditions Heating Operation Conditions
Indoor Air Inlet Temperature: 27°C DB (80°F DB) Indoor Air Inlet Temperature: 20°C DB (68°F DB)
19.0°C WB (66.2°F WB) Outdoor Air Inlet Temperature: 7°C DB (45°F DB)
Outdoor Air Inlet Temperature: 35°C DB (95°F DB) 6°C WB (43°F WB)
Piping Length: Refer to each General Specification for details. Piping Lift: 0 Meter
2. The above values indicate the EER/COP per outdoor unit when it is combined with specified indoor units.

FAN-2209 201709 1-19


FEATURES

(2) Energy Saving Technology

Bell-mouth Compressor

˂Long Bell-mouth Structure˃ ˂Improve Compressor Efficiency at


Create smooth air flow and reduce Low Load Operation˃
fan input by adopting multi-stage Optimize oil rate by improving oil
enhanced structure. distribution to the compressor and
expand operation range at low load
Long Blade Propeller Fan operation
Multi-stage
Enhanced Structure
Smooth air flow by
distributing multipolar
vortex.

Long Bell-mouth
Suppress leakage
and effectively operate
in wide range.

Heat Exchanger
˂Improve Efficiency at Low Load Cooling Operation with New Path Structure˃
Adopt best effective heat exchanger path structure during low load cooling operation. Divide heat exchanger
to upper and lower parts and modify path shape to be narrower as it reaches lower part and increase
refrigerant flow speed to improve thermal conductivity. Improved energy efficiency and cooling capacity.

● Operation Condition at Low Load Cooling Operation ● Ʃ Shape Heat Exchanger: ≥14HP Type
Adopt two fan structure for improve efficiency
at low load operation. Adopt Σ shape heat
Improve cooling capacity and energy exchanger to maximize the effect of the two fan
efficiency by adopting new path structure to
increase refrigerant flow speed. structure for better energy saving.
(ph Diagram Conceptual Drawing)

Sturation Curve
Condense

Pressure: p
(Mpa) Expand Compress

Evaporate

Cooling Capacity
Enthalpy: h(kJ/kg)

1-20 FAN-2209 201709


FEATURES

New Operation Control

■ Smooth Drive Control System


Calculate the amount of refrigerant to charge based on the load information from the indoor units. Control
inverter compressor rotation speed and charge proper amount of refrigerant to indoor unit at each loading
condition. Suppress compressor switching ON/OFF at low load operation for better energy efficiency with
smooth operation.

■ Concept of Smooth Drive Control ■ Comparison at Low Load Operation


Charge proper amount of refrigerant. Refrigerant Flow Current New
Piping Supress switching
Repeat switching
ON/OFF and operate
ON/OFF operation.
smoothly.

Rotation Rotation
Speed Speed

Indoor Unit Indoor Unit


Room Room
Inverter Temp. Temp.
Compressor Transmit Transmit
Setting Temp. Setting Temp.
Load Load
Information Information Operation Hour Operation Hour
Outdoor Unit (Conceptual Drawing at Cooling Operation)
Transmission Line
(Conceptual Drawing)

Calculate proper amount of refrigerant to charge according to the load information.

● Verification Result of Energy Saving Effect from Smooth Drive Control


The verification result of energy saving effect at part load testing chamber is shown below. The
“Smooth Drive Control System” suppress the compressor switching ON/OFF operation and keep
room temperature stable. The reduction of power consumption has been verified.
▪ Current Control System ▪ New Control SYstem (Smooth Drive Control)
(at Cooling Operation, Load Factor: Approx.33%) (at Cooling Operation, Load Factor: Approx.33%)
Power Consumption: 1.49kW Reduce
Power Consumption: 2.46kW
(Approx.61% of current system) Approx.
Indoor Unit 30 30
39%
Inlet Temp.
(oC) 25 25
Unstable Temperature
Caused by Frequent Switching ON/OFF Operation. Stable Temperature
20 20

15 15

10 Energy Loss Caused by Switching ON/OFF Operation. 10 Suppress Switching ON/OFF Operation

Power 5 5
Consumption
(kW)
0 0
0 60 120 180 0 60 120 180
Time (min.) Time (min.)

The verification test has been implemented with the combination of current Japanese domestic
model VRF outdoor unit (RAS-AP280DG3) and two Japanese domestic model VRF 4-way cassette
indoor units (RCI-AP140K5)
<Testing Condition>
• Indoor Unit Inlet Temperature: 27oC (Dry Bulb) / 19oC (Wet Bulb)
• Ambient Temperature at Air Volume “High”: 23oC (Dry Bulb)
• Piping Length between Indoor Unit and Outdoor Unit: 15m
• Testing Location: Environment Testing Facility at Kansai Denryoku (power supply company)

FAN-2209 201709 1-21


FEATURES

Improvement of Energy-Saving by Schedule Setting of


“Self-Demand Function” from Central Station Mini, EX, DX and NT
“Self-Demand Function(*)” can be set per outdoor unit from Central Station Mini, EZ, DX and NT.
For small and medium buildings, it facilitates the power saving. The energy-saving operation can be adjusted
according to an operating environment and individual needs.
(*): Self-Demand Function: It saves the capacity in order not to exceed the demand current control according
to the electric power information which the air conditioner detects.

< Self-Demand Function (Image) >


Excessive power supply consumption
exceeding the power setting range
Power Consumption

is restricted.

Power Setting
Selectable from 100%,
Maximum efficiency is secured 80%, 70%, 60% and 40% of
within the power setting range. the rated power consumption
for cooling operation.
Morning Daytime Night
Operating Hours

< Setting Example: Schedule Setting for Each Group by Central Station DX >

Group A Group B

Group A Various operating methods


Power Setting

Power Setting: 80% are available depending on


purpose and needs.
Group B

Power Setting: 60%


8 A.M. 12 P.M. 3 P.M. 6 P.M. Time
Central Station DX
The specific outdoor unit and the period of time can be set from
Central Station DX.

NOTES:
1. The demand current control (%) is indicated by approximate values. The value in this control which is
calculated by the current is different precision from the value in the wattmeter.
If it is required that the maximum power consumption is managed precisely, a field-supplied demand
controller should be used.
2. The range may temporarily be higher than the power setting range (%) depending on the operating
control condition such as protection control.
3. When the above self-demand control is set, the performance is restricted because the rotation
frequency of compressor is forcibly decreased.

1-22 FAN-2209 201709


FEATURES

Flexibility of Facility Design


■ Improvement of Piping Installation
Height difference between the outdoor units and indoor units and height difference between the indoor
units have been changed as shown below.

Item Heat Recovery System

Height Difference Outdoor Unit is Higher < 50m (Standard)


between Outdoor Units
and Indoor Units NEW < 110m (*1)

Height Difference between Indoor Units < 15m

Outdoor Units
Max. Piping Length: 10m
Height Difference: 0.1m

Max. Height Difference


between Outdoor Units and Indoor Units:
• O.U. is Higher: 50m Max. Height Difference
110m*1 between CH-Box and
• O.U. is Lower: 40m Indoor Units: 15m

Max. Piping Length between


Max. Height Difference of
Branch from Indoor Unit: 40m (30m)*3
CH-Boxes: 15m

Max. Height Difference: 4m


(Same Branch of CH-Box)

Max. Height Difference of


Indoor Units: 15m
Piping Length between
CH-Box and Indoor Unit:
Total Piping Length: 40m

Piping Length between Outdoor Unit


Max. Piping Length of First Branch from and Indoor Unit:
Each Indoor Unit: 90m (40m)*3 Max. Piping Length: 165m
Max. Total Piping Length: 1000m (300m)*2, *3

NOTES:
*1: Contact your distributor or dealer if the height difference is over 50m.
*2: When the total piping length is over 300m, the maximum additional refrigerant charge is restricted.
The maximum additional refrigerant charge (table below) should not exceed the total field additional
charge (refrigerant pipe + indoor unit).
HP 5 to 10 12 14 to 18 20, 22 24 26 to 54
Max. Additional Refrigerant Charge (kg) 28.0 36.0 40.0 51.0 52.0 63.0

*3: If the piping length exceeds figure in ( )*, the connectable indoor units number should be less than
recommended number.

FAN-2209 201709 1-23


FEATURES

■ Lifting Limits on Main Piping Branch Numbers ()


No Limit for the Number of Main Piping Branch
No limit for the number of main piping branch is realized under the following restriction.
Piping Length from the Multi-Kit at the first branch
to the terminal Indoor Unit is within 40 ~ 90m
In the case that the piping length L2 from the L2

Multi-Kit at the first branch to the farthest indoor a b c e


d f
unit is over 40m, follow the instructions below
First Branch Terminal
when performing the field-supplied piping work. Multi-Kit The Closest Indoor Unit Indoor Unit
from the First Branch‫ޓ‬
L2
g
j Terminal
h Indoor Unit
i k

The Farthest Indoor Unit


Installation with Main Piping Branch () from the First Branch‫ޓ‬

(1) In the case that L2 is over 40m, the size of gas and liquid lines “b” or “g” should be increased by one
size with reducers (field-supplied).
* If (a) is one size smaller than (b, g) after increasing the size, increase the size of (a) to the same size
as (b, g).
* If (a) is two sizes smaller than (b, g) after increasing the size, increase (a) one size and reduce (b, g)
one size to be the same size. (L2 will be over 40m, the size of (b, g) should not be increased.)
(2) The difference between the piping length from the first branch to the farthest indoor unit and the piping
length from the first branch to the closest indoor unit must be within 40m.
* (g+h+j)-(b+d)<40m
(): Main Piping Branch: Both of the pipes branched from a Multi-Kit are connected to the next Multi-Kits.

■ Wide Range of Indoor Unit Connection


The number of connectable indoor unit with outdoor unit is as follows.
Comply with the condition as follows when installation.

Maximum Number of Connectable Indoor Units and Rang of Combination Capacity


Outdoor Unit Capacity
5 6 8 10 12 14 16, 18 20 22 24 26 28 30 32 34 36 38 - 54
(HP)
Range of Combination
50 to 130% (In case the combination ratio exceed 130%) (*1)
Capacity
Connectable
8 9 13 16 19 23 26 33 36 40 43 47 50 53 56 59 64
Indoor Units Q’ty
Recommended Connectable
5 8 10 16 18 20 26 32 38
Indoor Units Q’ty

NOTES:
1. The connectable indoor unit capacity ratio can be calculated as follows.
Connectable Indoor Unit Capacity Ratio = Total Indoor Unit Capacity / Total Outdoor Unit Capacity
2. For the system under which all the indoor units are supposed to operate simultaneously, the total indoor
unit capacity should be less than outdoor unit capacity. Otherwise, it may cause a decrease of operating
performance and operating limit in overload operation.
3. For the system under which all the indoor units are not supposed to operate simultaneously, the total indoor
unit capacity is available up to 130% against the outdoor unit capacity.
4. When operating the outdoor unit in cold areas with temperatures of -10°C, or under the high heating load
conditions, the total indoor unit capacity should be less than 100% against the outdoor unit capacity and the
total piping length should be less than 300m.
5. The air flow volume for indoor units of 0.4 and 1.0HP is set higher than that for indoor units of 1.5HP or more.
Make sure to select appropriate indoor units when installing indoor units where cold draft may occur during
heating operation. If installing indoor units in such places, refer to the recommended number of connectable
indoor units.
6. For connecting Tempclean Indoor Unit and Outdoor Air Processing Air Conditioner, the number of the indoor
units should be within recommended connectable indoor units number.
(*1) If combination capacity of indoor units exceed 100% of outdoor unit capacity, there might be the possibility
of insufficient capacity of 130% combination ratio. If combination capacity exceed 130% contact your
distributer or dealer.

1-24 FAN-2209 201709


FEATURES

■ Installation Flexibility for Expand External Static Pressure


For installation spaces such as a balcony or a floor where an external static pressure such as a louver or
a duct is required to secure, the 3 steps external static pressure (80Pa, 60Pa and 30Pa) by the dip switch
setting (DSW8) is newly adopted (current model is 60Pa only).

< Installation Example for Air Outlet Duct Kit >

Balcony Building

Setting for DSW8


External Static Pressure #1 #2
30Pa ON OFF
Installation of 60Pa OFF ON
outdoor units 80Pa ON ON
to each floor.

< Case that Open Space is Louver > < Case that Open Space is Wall >
Ceiling Wall Ceiling Wall Air Outlet Duct Kit
Air Outlet Duct Kit
(Field-Supplied)
(Field-Supplied)

Duct
(Field-Supplied)

The recommended
The air flow direction
air outlet duct kit
can be changed to
has flanged opening,
open space by using
which makes the field
air outlet duct kit.
connection work possible.

Louver Outdoor Unit Wall Outdoor Unit

NOTE:
Pay attention to the following case at the design and the installation. If the outlet air intakes by short-
circuit, the operation range is limited due to increasing high pressure in the cooling operation or
decreasing low pressure in the heating operation so that may cause failure of unit.

FAN-2209 201709 1-25


FEATURES

Wide Operation Range


This unit has been designed for cooling operation under low ambient temperatures down to -5°C.
This feature enables cooling to be obtained even in winter in buildings with high internal heat gains due to
lighting, people and machines, particularly in areas such as shops, lecture rooms, data processing areas etc.
And the heating operation under low ambient temperature down to -20°C can also be performed.

Cooling Operation
55

50
48
(*1)
45
43
40
Outdoor Air Inlet Temperature (oCDB)

35

Continuous Operation Range (*2)


Heating Operation
30 20

(at Pull-down Operation)


Operation Range
25 15

Outdoor Air Inlet Temperature (oCWB)

Continuous Operation Range (*4)


20 10

15 5

10 0

5 -5

0 -10

Additional Operation Range -5 -15


with Low Ambient Setting Operation
Range (*3)
-10 -20
15 20 23 25 10 15 20 25 27 30
Indoor Air Inlet Temperature (oCWB) Indoor Air Inlet Temperature (oCDB)

Heat Recovery Operation


Cooling Operation Heating Operation
Cooling Operation Heating Operation
Indoor
15 to 23oC WB 15 to 27oC DB 15 to 23oC WB 15 to 27oC DB
Air Inlet Temperature
-5 to 24oC DB
-5 to 48oC DB (*1)
-6 to 15oC WB
Outdoor
with Low Ambient Setting (*6) -20 to 15oC WB with Low Ambient Setting (*6)
Air Inlet Temperature
-10 to 48oC DB -10 to 24oC DB
-11 to 15oC WB

NOTES:
*1. (1) Cooling operation at maximum 48oC DB is available only if the outdoor air inlet temperature
increase temporarily caused by installation condition.
(2) If install the units to the place where continuously exceed ambient temperature 48oC, the
combination ratio must be lower than 130% and not to operate all of the indoor unit simultaneously.
(3) The cooling capacity is deteriorated at high ambient temperature. Select the larger capacity outdoor
unit than compatible building heat load.
(4) The appropriate amount (100%) of refrigerant must be charged. Excessive charging of refrigerant is
forbidden.
(5) Avoid to install the units where affected by direct sunlight reflection and short circuit. There may
be the possibility to activate protection control and alarm system if install the units to inappropriate
place. The life time of the products and parts are considerably shortened.
(6) Periodic maintenance (1/certain month) must be applied to the heat exchanger fin to avoid adhesion
of dirt and clogging of sand to the outdoor unit heat exchanger.

1-26 FAN-2209 201709


FEATURES

*2. There might be the possibility of thermo-OFF when operate the outdoor unit under the low cooling
load condition and in the low outdoor air temperature (10oC DB or lower) to prevent indoor unit heat
exchanger from frost formation.
*3. Indoor air inlet temperature at heating operation from 15oC to 27oC WB is under assumption of limited
time operation such as at the time of startup in the early morning and not suitable for long time
continuous operation.
*4. There might be the possibility of thermo-OFF when operate the outdoor unit under the low heating
load condition and in the high outdoor air temperature (higher than 15oC DB) to prevent the outdoor
unit. The outdoor unit operation stops when outdoor air inlet temperature exceed 26oC DB.
*5. Operational range is different when connect to All Fresh Air Unit, Econofresh, and other special
indoor units.
*6. In case cooling operation or simultaneous operation under the inlet air temperature -5oC or lower the
conditions listed below must be considered at the time of installation.
• Make sure to apply Snow Protection Hood (Optional Part) .
• The minimum capacity of indoor unit connectable is 2.5HP
• Set the function “Cooling Operation Under Low Load Operation” (DSW6) from the outdoor unit
(If multiple outdoor units are connected in a system set the function only for outdoor unit A).
• Make sure to apply new CH-Box (Optional Part).
The “Low Ambient Setting” is not available if the system is connected with current CH unit.

FAN-2209 201709 1-27


FEATURES

Improvement of Servicing and Easy Maintenance

■ Adopting Access Door for Electrical Box Cover


Improve serviceability and maintenance performance by adopting access door to electrical box cover. This
makes possible to access PCB without opening whole electrical box cover.

<Access Door Opened>

Electrical Box Cover

Access Door

The following operations are capable from the access door.


• Checking 7-segment and alarm display
• LED operation condition NOTE:
• PSW, DSW and RSW setting for function selection 1. Be sure to close the access door
• Connectiong service checker to TB2 (transmission terminal block) and retern to the original posision.
2. Operate the switches and push the
buttons with an insulated stick
(such as a closed ball-point pen) to
avoid electrical shocking.
■ Rotational Operation to Distribute Load of Outdoor Unit
■ Backup Operation Function for Emergency

Other Advance Technologies


■ Capacity Control by 0.1Hz
The highly improved performance as well as greater energy saving is achieved by adopting newly
developed high efficiency DC inverter compressor, with outstandingly precise control technology of 0.1Hz
increments inverter frequency. Another feature is the dramatically extended working range, enabled by
expanding the compressor’s operating frequency band, both upwards and downwards.

100% 100%
12 HP 12 HP
Inverter Compressor

Inverter Compressor
Control Capacity

Control Capacity

15Hz ~ 100Hz 11Hz ~ 110Hz


85 Steps 990 Steps
(by 1Hz) (by 0.1Hz)
Inverter Inverter
Compressor Compressor

20% 10%
Max. Min. Max. Min.
Cooling Load Cooling Load

<Current Model> <New Model>

1-28 FAN-2209 201709


FEATURES

Corresponding to H-LINK II System


This outdoor units corresponds to the H-LINK II transmission system. Maximum 64 refrigerant systems and
maximum 160 indoor units can be controlled by only one central control device when the equipments (central
control device, indoor units, remote control switch) in the same transmission system all correspond to H-LINK
II.

< System Example >


Outdoor Units (*Max. 64 Refrigerant Group)

Indoor Units (*Max. Connectable Q'ty: 160)

Central Control Device


: Control Line

Item H-LINK ll
Number of Max. Ref. Group / System 64
Address Setting Range of Indoor Units / Ref. Group 0 to 63
Number of Max. Indoor Unit / System 160
Total Q'ty of Central Control Devices in the same
200
H-LINK
Max. Wiring Length Total 1,000m (5,000m*)
*: In case 4 (four) units of PSC-5HR is used.

■ H-LINK II System
The H-LINK II wiring system requires only two transmission wires to connect each indoor unit and outdoor
unit for up to 64 refrigerant cycles, and to connect wires for all indoor units and outdoor units.

<Specifications>
* Transmission Wire: 2-Wire
* Polarity of Transmission Wire: Non-Polar Wire
* Maximum Outdoor Units to be Connected: 64 Units per System
* Maximum Indoor Units to be Connected: 160 Units per H-LINK II System
* Maximum Wiring Length: Total 1,000m (including CS-NET)
* Recommended Cable: Twist-Pair Cable with Shield, over 0.75mm2 (Equivalent to KPEV-S)
* Voltage: DC5V

NOTE:
In case of applying H-LINK II system, the setting of dip switch for outdoor unit and indoor unit is required.
If the dip switches are not set or set incorrectly, the alarm may occur due to a transmission failure.

■ Setting of End Terminal Resistance


Setting of End Terminal Resistance
Before shipment, No.1 pin of DSW10 is in the "ON" position.
DSW10
In the case that the number of outdoor units in the same H-LINK is
2 or more, set No.1 pin of DSW10 at "OFF" from the 2nd unit. Before Shipment Cancellation
If only one outdoor unit is used, no setting is required. ON ON

1 2 OFF 1 2 OFF

FAN-2209 201709 1-29


FEATURES

Anti-Corrosion Type (Order Product)


■ Installation Place

Anti-Corrosion Type Heavy Anti-Corrosion Type


The place where a salt air does not blow onto the The place is affected by the salt air. (However,
outdoor unit directly. (However, a salt particles a salt water does not spatter on the outdoor unit
are contained in an ambient air.) directly.)
300m to 1000m within 300m
Installation Outdoor
Place Unit

Outdoor
Unit
Sea Sea

* The place where the outdoor unit is washed by * The place where rain is scarce.
rain. * The place where a salt air blow onto the outdoor
* The place where a salt air is not blown onto the unit directly.
Condition outdoor unit directly. * The place where the distance between
of
* The place where the distance between seacoast seacoast and the outdoor unit is within 300m.
Installation
and the outdoor unit is 300m to 1000m. * The place where the outdoor unit faces to the
Place
* The place where the outdoor unit is installed seacoast.
behind a building as shown in the figure.

■ Rough Standard of Distance from Installation Place to Seacoast


(The conditions may be changed depending on the installation environments.)

● Place where Salt Air Blows Directly


Rough Standard of Distance from Installation Place
300m 500m 1000m
Area Faces to Landlocked Bay Heavy Anti-Corrosion Anti-Corrosion
Area Faces to Broad Ocean Heavy Anti-Corrosion Anti-Corrosion
Isolated Island Heavy Anti-Corrosion

● Place where Salt Air does Not Blow Directly


Rough Standard of Distance from Installation Place
300m 500m 1000m
Area Faces to Landlocked Bay Anti-Corrosion
Area Faces to Broad Ocean Heavy Anti-Corrosion Anti-Corrosion
Isolated Island Heavy Anti-Corrosion Anti-Corrosion

1-30 FAN-2209 201709


FEATURES

■ Notice for Installation and Maintenance


● Notice for Installation (Maintenance)
The using materials and coating thickness for the anti-corrosion type and heavy anti-corrosion type are
strengthened. However, it is somewhat less than perfect against corrosion. Therefore, perform the
following installation plan and maintenance work to increase the effect of anti-corrosion.
(1) Do not install the outdoor units in a place where salt air or mist is directly blown to the units.
* Select an installing place such as behind a building.
* When the outdoor unit is faced to the seacoast, install a windbreak board to avoid direct salt air
blowing.
(2) Do not cover the outdoor unit with sunshades, etc. so as not to decrease the cleaning effect by rain for
the salt particles adhere to the outer covers of the outdoor unit.
(3) Install the outdoor unit horizontally for smooth draining. Because remained condensate on the bottom
base worsens a corrosion severely.
(4) Periodically perform maintenance work by clean water to remove salt particles, etc. on the surface of the
outdoor unit’s outer covers.
(5) Install the unit where the drainage is smooth. Especially provide the drainage around foundation
smoothly.
(6) Repair scratches which occurred during installation and maintenance work.
(7) Periodically check outdoor unit. If needed, provide again the anti-corrosion treatment or replace it with
service parts.
● Note for Maintenance
(1) Perform the maintenance work sufficiently for the outdoor unit. (Coat the outer covers of the outdoor unit
by the resin or wax that sheds water when applying anti-corrosive coating and every three months.)
(2) If the outdoor unit has not been operated for a long period such as off-season, take countermeasures to
cover the unit, etc.
T Do not install the outdoor unit where there is a high level of oil mist, flammable gases, salty air or harmful
gases such as sulphur and an acid or alkaline environment.

FAN-2209 201709 1-31


FEATURES

(1) SPECIFICATIONS OF STANDARD COATING TREATMENT


Component Material Specifications
Outer Plates Pre-coat Treatment Galvanized Steel Zinc Phosphate Coating Treatment and
Polyester Type Resin Pre-coating over Outer Surface
Total Thickness: >15µm
Alloy Processing Zinc Steel Zinc Phosphate Coating Treatment and
Baked with Acrylic Type Resin Coating over Whole Surface
Total Thickness: >15µm
Bottom Base Alloy Processing Zinc Steel Zinc Phosphate Coating Treatment and
Baked with Polyester Type Resin Coating over Whole Surface
Total Thickness: >15µm
Legs Alloy Processing Zinc Steel Zinc Phosphate Coating Treatment and
Baked with Epoxy Type Resin Coating over Whole Surface
Total Thickness: >15µm
Electrical Box Galvanized Steel ---
Attaching Plate Galvanized Steel ---
Heat Exchanger Fin Aluminum with Epoxy Type Resin
---
Coating Treatment
Heat Exchanger Side Galvanized Steel
---
Plate
Refrigeration Piping Brazing Part Copper ---
Copper Pipe Surface Copper ---
Motor Clamp Galvanized Steel ---
Motor Aluminum Die-Casting ---
Fan Blade AS-G Resin ---
Bell Mouth PP Resin ---
Air Outlet Grille Low-Carbon Steel Wire Rod Polyethylene Coating
Total Thickness: >300µm
Accumulator Carbon Steel Pipe Zinc Phosphate Coating Treatment and
Baked with Epoxy Type Resin Coating over Outer Surface
Total Thickness: >15µm
Oil Separator Copper Pipe ---
Fixing Screw for Stainless Steel
---
Outer Panel
NOTES:
1. The coating thickness of the part where a screw, hole, cut end or corner laps on a steel plate, which is not directly exposed
to the atmosphere, is thinner than the above specifications. Also, the coating thickness of a panel which is not directly
exposed to outdoor rain water is thinner than the above specifications.
2. In order to improve our products, the specifications are subject to change without notice.

1-32 FAN-2209 201709


FEATURES

(2) SPECIFICATIONS OF ANTI-CORROSIVE COATING TREATMENT


Component Material Specifications
Outer Plates Pre-coat Treatment Galvanized Steel Zinc Phosphate Coating Treatment and Polyester Type Resin
Pre-coating over Outer Surface
Baked with Polyester Type Resin Coating over Outer Surface
Total Thickness: ≥ 30µm
Bottom Base Alloy Processing Zinc Steel Zirconium Phosphate Coating Treatment and Baked with
Polyester Type Resin Coating over Whole Surface
Total Thickness: ≥ 30µm
Legs Alloy Processing Zinc Steel Zinc Phosphate Coating Treatment and Baked with Epoxy Type
Resin Coating over Whole Surface
Total Thickness: ≥ 30µm
Air Outlet Grille Low Carbon Steel Wire Rod Polyethylene Coating
Thickness: ≥ 300µm
Electrical Box Galvanized Steel ---
Attaching Plate Galvanized Steel or Zinc Phosphate Coating Treatment or Zirconium Phosphate
Alloy Processing Zinc Steel Coating Treatment and Baked with Polyester Type Resin
Coating
Total Thickness: ≥ 15µm
(Except for some small parts)
Heat Exchanger Fin Aluminum with Epoxy Type Resin
---
Coating Treatment
Heat Exchanger Side Highly Corrosion-resistant Coated
Plate Steel
---
(Hot-dip Zinc-aluminum-magnesium
Alloy-coated Steel)
Refrigeration Piping Brazing Part Copper ---
Copper Pipe Surface Copper ---
Motor Clamp Alloy Processing Zinc Steel Zinc Phosphate Coating Treatment or Zirconium Phosphate
Coating Treatment and Baked with Polyester Type Resin
Coating
Total Thickness: ≥ 15µm
Motor Aluminum Die-Casting and Polyester
---
Resin
Fan Blade AS-G Resin ---
Bell Mouth PP Resin ---
Accumulator Carbon Steel Pipe Zinc Phosphate Coating Treatment and Baked with Epoxy Type
Resin Coating over Outer Surface
Total Thickness: ≥ 60µm
Oil Separator Copper Pipe ---
Fixing Screw for Stainless Steel
---
Outer Panel
NOTES:
1. The coating thickness of the part where a screw, hole, cut end or corner laps on a steel plate, which is not directly exposed
to the atmosphere, is thinner than the above specifications. Also, the coating thickness of a panel which is not directly
exposed to outdoor rain water is thinner than the above specifications.
2. In order to improve our products, the specifications are subject to change without notice.

FAN-2209 201709 1-33


FEATURES

(3) SPECIFICATIONS OF HEAVY ANTI-CORROSIVE COATING TREATMENT


Component Material Specifications
Outer Plates Pre-coat Treatment Galvanized Steel Zinc Phosphate Coating Treatment and Polyester Type Resin
Pre-coating over Outer Surface
Baked with Polyester Type Resin Coating over Outer Surface
Total Thickness: ≥ 45µm
Bottom Base Alloy Processing Zinc Steel Zirconium Phosphate Coating Treatment and Baked with
Polyester Type Resin Coating over Whole Surface
Total Thickness: ≥ 45µm
Legs Alloy Processing Zinc Steel Zinc Phosphate Coating Treatment and Baked with Epoxy Type
Resin Coating over Whole Surface
Total Thickness: ≥ 45µm
Air Outlet Grille Low Carbon Steel Wire Rod Polyethylene Coating
Thickness: ≥ 300µm
Electrical Box Alloy Processing Zinc Steel Zinc Phosphate Coating Treatment or Zirconium Phosphate
Attaching Plate Galvanized Steel or Coating Treatment and Baked with Polyester Type Resin
Alloy Processing Zinc Steel Coating
Total Thickness: ≥ 15µm
(Except for some small parts)
Heat Exchanger Fin Aluminum with Epoxy Type Resin
---
Coating Treatment
Heat Exchanger Side Highly Corrosion-resistant Coated
Plate Steel
---
(Hot-dip Zinc-aluminum-magnesium
Alloy-coated Steel)
Refrigeration Piping Brazing Part Copper ---
Copper Pipe Surface Copper ---
Motor Clamp Alloy Processing Zinc Steel Zinc Phosphate Coating Treatment or Zirconium Phosphate
Coating Treatment and Baked with Polyester Type Resin
Coating
Total Thickness: ≥ 15µm
Motor Aluminum Die-Casting and Polyester
---
Resin
Fan Blade AS-G Resin ---
Bell Mouth PP Resin ---
Accumulator Carbon Steel Pipe Zinc Phosphate Coating Treatment and Baked with Epoxy Type
Resin Coating over Outer Surface
Total Thickness: ≥ 60µm
Oil Separator Copper Pipe ---
Fixing Screw for Stainless Steel
---
Outer Panel
NOTES:
1. The coating thickness of the part where a screw, hole, cut end or corner laps on a steel plate, which is not directly exposed
to the atmosphere, is thinner than the above specifications. Also, the coating thickness of a panel which is not directly
exposed to outdoor rain water is thinner than the above specifications.
2. In order to improve our products, the specifications are subject to change without notice.

Caution Items for Installation and Maintenance on


Anti-Corrosion and Heavy Anti-Corrosion Treatment Units

1) Do not install the units in a place where salty air or mist is directly blown to the units.
2) Install the unit so as rain can wash off salt particles onto the panels.
(ex. Do not cover the unit with sunshades.)
3) Pay attention to level of the unit so that water on the bottom base can flow smoothly because
the remained water on the bottom base of the outdoor unit worsens corrosion severely.
4) Periodically perform maintenance work by clean water to remove salt particles, etc.
5) Repair scratches which occurred during installation and maintenance work.
6) Periodically check each component. If needed, replace it with service parts.
7) Provide the drainage around foundation smoothly.

1-34 FAN-2209 201709


GENERAL DATA

2. General Data
2.1 Outdoor Units

Model

JTOR080VPE(U,F,R)BS1 JTOR100VPE(U,F,R)BS1 JTOR120VPE(U,F,R)BS1
Power Supply 3~,460V/60Hz, 3~/N,380V/60Hz, 3~,220V/60Hz
Nominal Cooling Capacity kW 22.4 28.0 33.5
Nominal Heating Capacity kW 25.0 31.5 37.5
Cabinet Color (Munsell Code) Natural Gray (1.0Y 8.5/0.5)
Sound Power Level dB(A) 80 82 82
Sound Pressure Level dB(A) 58 60 59
Outer Dimensions
Height x Width x Depth mm 1,675 x 950 x 765 1,675 x 950 x 765 1,675 x 950 x 765
Net Weight
460V/60Hz kg 200 200 220
380V/60Hz kg 195 195 215
220V/60Hz kg 190 190 210
Gross Weight
460V/60Hz kg 216 216 236
380V/60Hz kg 211 211 231
220V/60Hz kg 206 206 226
Refrigerant R410A
Flow Control Micro-Control Computer Expansion Valve
Compressor 284 + 328 + 328
Model AA50PHD AA50PHD DC80PHD
Quantity 1 1 1
Motor Output (Pole) kW 3.3 (6) 4.3 (6) 5.4 (6)
Refrigeration Oil
Type FVC68D
Charge L/Unit 6.0 6.0 6.0
Heat Exchanger Multi-Pass Cross-Finned Tube
Condenser Fan Propeller Fan
Quantity 1 1 1
Air Flow Rate m 3/min. 165 170 190
Motor Output (Pole) kW 0.26 (8) 0.28 (8) 0.42 (8)
Main Refrigerant Piping
Heat Recovery System (3 Pipes)
Liquid Line mm (in.) 9.52 (3/8) 9.52 (3/8) 12.7 (1/2)
Gas Line
Low Pressure mm (in.) 19.05 (3/4) 22.2 (7/8) 25.4 (1)
High/Low Pressure mm (in.) 15.88 (5/8) 19.05 (3/4) 22.2 (7/8)
Refrigerant Charge
kg 5.0 5.0 7.2
(before Shipment)
Packing Dimensions
Height x Width x Depth mm 1,800 x 1,030 x 810 1,800 x 1,030 x 810 1,800 x 1,030 x 810
Approximate
Packing Measurement m3 1.5 1.5 1.5
NOTES:
1. The cooling and heating performances are the values when combined with our specified indoor units.
Cooling Operation Conditions Heating Operation Conditions
Indoor Air Inlet Temperature: 27oC DB (80oF DB) Indoor Air Inlet Temperature: 20oC DB (68oF DB)
o o
19.0 C WB (66.2 F WB) Outdoor Air Inlet Temperature: 7oC DB (45oF DB)
o o
Outdoor Air Inlet Temperature: 35 C DB (95 F DB) 6oC WB (43 oF WB)
Piping Length: 7.5 Meters Piping Lift: 0 Meter
2. The sound pressure is based on the following conditions.
1 Meter from the unit service cover surface, and 1.5 Meters from floor level.
The above data is based on the cooling mode. In case of heating mode, the sound pressure level increases by approximately 1~2 dB.
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
※ The 11th digit of the model name indicate the power supply of each unit.
U: 460V/60Hz F: 380V/60Hz R: 220V/60Hz

FAN-2209 201709 1-35


GENERAL DATA

Model

JTOR140VPE(U,F,R)BS1 JTOR160VPE(U,F,R)BS1 JTOR180VPE(U,F,R)BS1
Power Supply 3~,460V/60Hz, 3~/N,380V/60Hz, 3~,220V/60Hz
Nominal Cooling Capacity kW 40.0 45.0 50.0
Nominal Heating Capacity kW 45.0 50.0 56.0
Cabinet Color (Munsell Code) Natural Gray (1.0Y 8.5/0.5)
Sound Power Level dB(A) 85 85 86
Sound Pressure Level dB(A) 63 63 65
Outer Dimensions
Height x Width x Depth mm 1,675 x 1,210 x 765 1,675 x 1,210 x 765 1,675 x 1,210 x 765
Net Weight
460V/60Hz kg 276 319 320
380V/60Hz kg 271 314 315
220V/60Hz kg 266 309 310
Gross Weight
460V/60Hz kg 294 337 338
380V/60Hz kg 289 332 333
220V/60Hz kg 284 327 328
Refrigerant R410A
Flow Control Micro-Computer Control Expansion Valve
Compressor 284 + 328 + 328
Model DC80PHD AA50PHD + AA50PHD AA50PHD + AA50PHD
Quantity 1 2 2
Motor Output (Pole) kW 8.0 (6) 4.5 (6) × 2 5.0 (6) × 2
Refrigeration Oil
Type FVC68D
Charge L/Unit 6.9 7.9 7.9
Heat Exchanger Multi-Pass Cross-Finned Tube
Condenser Fan Propeller Fan
Quantity 2 2 2
Air Flow Rate m 3/min. 239 256 256
Motor Output (Pole) kW 0.33 (8) x 2 0.39 (8) x 2 0.39 (8) x 2
Main Refrigerant Piping
Heat Recovery System (3 Pipes)
Liquid Line mm (in.) 12.7 (1/2) 12.7 (1/2) 15.88 (5/8)
Gas Line
Low Pressure mm (in.) 25.4 (1) 28.58 (1-1/8) 28.58 (1-1/8)
High/Low Pressure mm (in.) 22.2 (7/8) 22.2 (7/8) 22.2 (7/8)
Refrigerant Charge
kg 8.9 9.9 10.7
(before Shipment)
Packing Dimensions
Height x Width x Depth mm 1,800 x 1,290 x 810 1,800 x 1,290 x 810 1,800 x 1,290 x 810
Approximate
Packing Measurement m3 1.9 1.9 1.9
NOTES:
1. The cooling and heating performances are the values when combined with our specified indoor units.
Cooling Operation Conditions Heating Operation Conditions
Indoor Air Inlet Temperature: 27oC DB (80oF DB) Indoor Air Inlet Temperature: 20oC DB (68oF DB)
o o
19.0 C WB (66.2 F WB) Outdoor Air Inlet Temperature: 7oC DB (45oF DB)
o o
Outdoor Air Inlet Temperature: 35 C DB (95 F DB) 6oC WB (43 oF WB)
Piping Length: 7.5 Meters Piping Lift: 0 Meter
2. The sound pressure is based on the following conditions.
1 Meter from the unit service cover surface, and 1.5 Meters from floor level.
The above data is based on the cooling mode. In case of heating mode, the sound pressure level increases by approximately 1~2 dB.
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
※ The 11th digit of the model name indicate the power supply of each unit.
U: 460V/60Hz F: 380V/60Hz R: 220V/60Hz

1-36 FAN-2209 201709


GENERAL DATA

Model

JTOR200VPE(U,F,R)BS1 JTOR220VPE(U,F,R)BS1 JTOR240VPE(U,F,R)BS1
Power Supply 3~,460V/60Hz, 3~/N,380V/60Hz, 3~,220V/60Hz
Nominal Cooling Capacity kW 56.0 61.5 67.0
Nominal Heating Capacity kW 63.0 69.0 77.5
Cabinet Color (Munsell Code) Natural Gray (1.0Y 8.5/0.5)
Sound Power Level dB(A) 86 84 86
Sound Pressure Level dB(A) 65 64 66
Outer Dimensions
Height x Width x Depth mm 1,675 x 1,600 x 765 1,675 x 1,600 x 765 1,675 x 1,600 x 765
Net Weight
460V/60Hz kg 360 374 375
380V/60Hz kg 355 369 370
220V/60Hz kg 350 364 365
Gross Weight
460V/60Hz kg 380 394 395
380V/60Hz kg 375 389 390
220V/60Hz kg 370 384 385
Refrigerant R410A
Flow Control Micro-Computer Control Expansion Valve
Compressor
Model AA50PHD + AA50PHD DC80PHD + DC80PHD DC80PHD + DC80PHD
Quantity 2 2 2
Motor Output (Pole) kW 5.5 (6) x 2 6.7 (6) x 2 7.1 (6) x 2
Refrigeration Oil
Type FVC68D
Charge L/Unit 8.4 8.4 8.4
Heat Exchanger Multi-Pass Cross-Finned Tube
Condenser Fan Propeller Fan
Quantity 2 2 2
Air Flow Rate m 3/min. 329 329 348
Motor Output (Pole) kW 0.48 (8) x 2 0.48 (8) x 2 0.56 (8) x 2
Main Refrigerant Piping
Heat Recovery System (3 Pipes)
Liquid Line mm (in.) 15.88 (5/8) 15.88 (5/8) 15.88 (5/8)
Gas Line
Low Pressure mm (in.) 28.58 (1-1/8) 28.58 (1-1/8) 28.58 (1-1/8)
High/Low Pressure mm (in.) 22.2 (7/8) 25.4 (1) 25.4 (1)
Refrigerant Charge
kg 11.3 11.3 11.6
(before Shipment)
Packing Dimensions
Height x Width x Depth mm 1,800 x 1,680 x 810 1,800 x 1,680 x 810 1,800 x 1,680 x 810
Approximate
Packing Measurement m3 2.4 2.4 2.4
NOTES:
1. The cooling and heating performances are the values when combined with our specified indoor units.
Cooling Operation Conditions Heating Operation Conditions
Indoor Air Inlet Temperature: 27oC DB (80oF DB) Indoor Air Inlet Temperature: 20oC DB (68oF DB)
o o
19.0 C WB (66.2 F WB) Outdoor Air Inlet Temperature: 7oC DB (45oF DB)
o o
Outdoor Air Inlet Temperature: 35 C DB (95 F DB) 6oC WB (43 oF WB)
Piping Length: 10 Meters Piping Lift: 0 Meter
2. The sound pressure is based on the following conditions.
1 Meter from the unit service cover surface, and 1.5 Meters from floor level.
The above data is based on the cooling mode. In case of heating mode, the sound pressure level increases by approximately 1~2 dB.
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
※ The 11th digit of the model name indicate the power supply of each unit.
U: 460V/60Hz F: 380V/60Hz R: 220V/60Hz

FAN-2209 201709 1-37


GENERAL DATA

Model ※ JTOR260VAE(U,F,R)BS1 JTOR280VAE(U,F,R)BS1 JTOR300VAE(U,F,R)BS1


JTOR120VPE(U,F,R)BS1 JTOR120VPE(U,F,R)BS1 JTOR120VPE(U,F,R)BS1
Combination of Base Unit
JTOR140VPE(U,F,R)BS1 JTOR160VPE(U,F,R)BS1 JTOR180VPE(U,F,R)BS1
Power Supply 3~,460V/60Hz, 3~/N,380V/60Hz, 3~,220V/60Hz
Nominal Cooling Capacity kW 73.0 77.5 85.0
Nominal Heating Capacity kW 82.5 90.0 95.0
Cabinet Color (Munsell Code) Natural Gray (1.0Y 8.5/0.5)
Sound Power Level dB(A) 87 87 87
Sound Pressure Level dB(A) 64.5 64.5 66
Outer Dimensions
Height x Width x Depth mm 1,675 x 2,180 x 765 1,675 x 2,180 x 765 1,675 x 2,180 x 765
Net Weight
460V/60Hz kg 220 + 276 220 + 319 220 + 320
380V/60Hz kg 215 + 271 215 + 314 215 + 315
220V/60Hz kg 210 + 266 210 + 309 210 + 310
Gross Weight
460V/60Hz kg 236 + 294 236 + 337 236 + 338
380V/60Hz kg 231 + 289 231 + 332 231 + 333
220V/60Hz kg 226 + 284 226 + 327 226 + 328
Refrigerant R410A
Flow Control Micro-Computer Control Expansion Valve
Compressor Hermetic (Scroll)
Model DC80PHD + DC80PHD DC80PHD + AA50PHD + AA50PHD DC80PHD + AA50PHD +AA50PHD
Quantity 2 3 3
Motor Output (Pole) kW 5.4 (6) x 1 + 8.0 (6) x 1 5.4 (6) x 1 + 4.5 (6) x 2 5.4 (6) x 1 + 5.0 (6) x 2
Refrigeration Oil
Type FVC68D
Charge L/Unit 12.9 13.9 13.9
Heat Exchanger Multi-Pass Cross-Finned Tube
Condenser Fan Propeller Fan
Quantity 3 3 3
Air Flow Rate m3/min. 190 + 239 190 + 256 190 + 256
Motor Output (Pole) kW 0.42 (8) + 0.33 (8) x 2 0.42 (8) + 0.39 (8) x 2 0.42 (8) + 0.39 (8) x 2
Main Refrigerant Piping
Heat Recovery System (3 Pipes)
Liquid Line mm (in.) 19.05 (3/4) 19.05 (3/4) 19.05 (3/4)
Gas Line
Low Pressure mm (in.) 31.75 (1-1/4) 31.75 (1-1/4) 31.75 (1-1/4)
High/Low Pressure mm (in.) 25.4 (1) 28.58 (1-1/8) 28.58 (1-1/8)
Refrigerant Charge
kg 16.1 17.1 17.9
(before Shipment)
NOTES:
1. The cooling and heating performances are the values when combined with our specified indoor units.
Cooling Operation Conditions Heating Operation Conditions
Indoor Air Inlet Temperature: 27oC DB (80oF DB) Indoor Air Inlet Temperature: 20oC DB (68oF DB)
19.0oC WB (66.2 oF WB) Outdoor Air Inlet Temperature: 7oC DB (45oF DB)
Outdoor Air Inlet Temperature: 35oC DB (95oF DB) 6oC WB (43 oF WB)
Piping Length: 10 Meters Piping Lift: 0 Meter
2. The sound pressure is based on the following conditions.
1 Meter from the unit service cover surface, and 1.5 Meters from floor level.
The above data is based on the cooling mode. In case of heating mode, the sound pressure level increases by approximately 1~2 dB.
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
3. Except for the specified combination in the table (26~54HP), there is no other combination of the base unit.
4. The width of outer dimension, it is the value when each distance between the base outdoor units is specified to 20mm.
※ The 11th digit of the model name indicate the power supply of each unit.
U: 460V/60Hz F: 380V/60Hz R: 220V/60Hz

1-38 FAN-2209 201709


GENERAL DATA

Model ※ JTOR320VAE(U,F,R)BS1 JTOR340VAE(U,F,R)BS1 JTOR360VAE(U,F,R)BS1


JTOR140VPE(U,F,R)BS1 JTOR160VPE(U,F,R)BS1 JTOR180VPE(U,F,R)BS1
Combination of Base Unit
JTOR180VPE(U,F,R)BS1 JTOR180VPE(U,F,R)BS1 JTOR180VPE(U,F,R)BS1
Power Supply 3~,460V/60Hz, 3~/N,380V/60Hz, 3~,220V/60Hz
Nominal Cooling Capacity kW 90.0 95.0 100.0
Nominal Heating Capacity kW 100.0 106.0 112.0
Cabinet Color (Munsell Code) Natural Gray (1.0Y 8.5/0.5)
Sound Power Level dB(A) 89 89 89
Sound Pressure Level dB(A) 67 67 68
Outer Dimensions
Height x Width x Depth mm 1,675 x 2,440 x 765 1,675 x 2,440 x 765 1,675 x 2,440 x 765
Net Weight
460V/60Hz kg 276 + 320 319 + 320 320 + 320
380V/60Hz kg 271 + 315 314 + 315 315 + 315
220V/60Hz kg 266 + 310 309 + 310 310 + 310
Gross Weight
460V/60Hz kg 294 + 338 337 + 338 338 + 338
380V/60Hz kg 289 + 333 332 + 333 333 + 333
220V/60Hz kg 284 + 328 327 + 328 328 + 328
Refrigerant R410A
Flow Control Micro-Computer Control Expansion Valve
Compressor Hermetic (Scroll)
AA50PHD + AA50PHD AA50PHD + AA50PHD
Model DC80PHD + AA50PHD + AA50PHD + AA50PHD + AA50PHD + AA50PHD + AA50PHD
Quantity 3 4 4
Motor Output (Pole) kW 8.0 (6) x 1 + 5.0 (6) x 2 4.5 (6) x 2 + 5.0 (6) x 2 5.0 (6) x 2 + 5.0 (6) x 2
Refrigeration Oil
Type FVC68D
Charge L/Unit 14.8 15.8 15.8
Heat Exchanger Multi-Pass Cross-Finned Tube
Condenser Fan Propeller Fan
Quantity 4 4 4
Air Flow Rate m3/min. 239 + 256 256 x 2 256 x 2
Motor Output (Pole) kW 0.33 (8) x 2 + 0.39 (8) x 2 0.39 (8) x 2 + 0.39 (8) x 2 0.39 (8) x 2 + 0.39 (8) x 2
Main Refrigerant Piping
Heat Recovery System (3 Pipes)
Liquid Line mm (in.) 19.05 (3/4) 19.05 (3/4) 19.05 (3/4)
Gas Line
Low Pressure mm (in.) 31.75 (1-1/4) 31.75 (1-1/4) 38.1 (1-1/2)
High/Low Pressure mm (in.) 28.58 (1-1/8) 28.58 (1-1/8) 28.58 (1-1/8)
Refrigerant Charge
kg 19.6 20.6 21.4
(before Shipment)
NOTES:
1. The cooling and heating performances are the values when combined with our specified indoor units.
Cooling Operation Conditions Heating Operation Conditions
Indoor Air Inlet Temperature: 27oC DB (80oF DB) Indoor Air Inlet Temperature: 20oC DB (68oF DB)
o o
19.0 C WB (66.2 F WB) Outdoor Air Inlet Temperature: 7oC DB (45oF DB)
o o
Outdoor Air Inlet Temperature: 35 C DB (95 F DB) 6oC WB (43 oF WB)
Piping Length: 12.5 Meters Piping Lift: 0 Meter
2. The sound pressure is based on the following conditions.
1 Meter from the unit service cover surface, and 1.5 Meters from floor level.
The above data is based on the cooling mode. In case of heating mode, the sound pressure level increases by approximately 1~2 dB.
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
3. Except for the specified combination in the table (26~54HP), there is no other combination of the base unit.
4. The width of outer dimension, it is the value when each distance between the base outdoor units is specified to 20mm.
※ The 11th digit of the model name indicate the power supply of each unit.
U: 460V/60Hz F: 380V/60Hz R: 220V/60Hz

FAN-2209 201709 1-39


GENERAL DATA

Model ※ JTOR380VAE(U,F,R)BS1 JTOR400VAE(U,F,R)BS1 JTOR420VAE(U,F,R)BS1


JTOR140VPE(U,F,R)BS1 JTOR180VPE(U,F,R)BS1 JTOR180VPE(U,F,R)BS1
Combination of Base Unit
JTOR240VPE(U,F,R)BS1 JTOR220VPE(U,F,R)BS1 JTOR240VPE(U,F,R)BS1
Power Supply 3~,460V/60Hz, 3~/N,380V/60Hz, 3~,220V/60Hz
Nominal Cooling Capacity kW 106.0 112.0 118.0
Nominal Heating Capacity kW 118.0 125.0 132.0
Cabinet Color (Munsell Code) Natural Gray (1.0Y 8.5/0.5)
Sound Power Level dB(A) 89 88 89
Sound Pressure Level dB(A) 68 67.5 68.5
Outer Dimensions
Height x Width x Depth mm 1,675 x 2,830 x 765 1,675 x 2,830 x 765 1,675 x 2,830 x 765
Net Weight
460V/60Hz kg 276 + 375 320 + 374 320 + 375
380V/60Hz kg 271 + 370 315 + 369 315 + 370
220V/60Hz kg 266 + 365 310 + 364 310 + 365
Gross Weight
460V/60Hz kg 294 + 395 338 + 394 338 + 395
380V/60Hz kg 289 + 390 333 + 389 333 + 390
220V/60Hz kg 284 + 385 328 + 384 328 + 385
Refrigerant R410A
Flow Control Micro-Computer Control Expansion Valve
Compressor Hermetic (Scroll)
AA50PHD + AA50PHD AA50PHD + AA50PHD
Model DC80PHD + DC80PHD + DC80PHD + DC80PHD + DC80PHD + DC80PHD + DC80PHD
Quantity 3 4 4
Motor Output (Pole) kW 8.0 (6) x 1 + 7.1 (6) x 2 5.0 (6) x 2 + 6.7 (6) x 2 5.0 (6) x 2 + 7.1 (6) x 2
Refrigeration Oil
Type FVC68D
Charge L/Unit 15.3 16.3 16.3
Heat Exchanger Multi-Pass Cross-Finned Tube
Condenser Fan Propeller Fan
Quantity 4 4 4
Air Flow Rate m3/min. 239 + 348 256 + 329 256 + 348
Motor Output (Pole) kW 0.33 (8) x 2 + 0.56 (8) x 2 0.39 (8) x 2 + 0.48 (8) x 2 0.39 (8) x 2 + 0.56 (8) x 2
Main Refrigerant Piping
Heat Recovery System (3 Pipes)
Liquid Line mm (in.) 19.05 (3/4) 19.05 (3/4) 19.05 (3/4)
Gas Line
Low Pressure mm (in.) 38.1 (1-1/2) 38.1 (1-1/2) 38.1 (1-1/2)
High/Low Pressure mm (in.) 31.75 (1-1/4) 31.75 (1-1/4) 31.75 (1-1/4)
Refrigerant Charge
kg 20.5 22.0 22.3
(before Shipment)
NOTES:
1. The cooling and heating performances are the values when combined with our specified indoor units.
Cooling Operation Conditions Heating Operation Conditions
Indoor Air Inlet Temperature: 27oC DB (80oF DB) Indoor Air Inlet Temperature: 20oC DB (68oF DB)
o o
19.0 C WB (66.2 F WB) Outdoor Air Inlet Temperature: 7oC DB (45oF DB)
o o
Outdoor Air Inlet Temperature: 35 C DB (95 F DB) 6oC WB (43 oF WB)
Piping Length: 12.5 Meters Piping Lift: 0 Meter
2. The sound pressure is based on the following conditions.
1 Meter from the unit service cover surface, and 1.5 Meters from floor level.
The above data is based on the cooling mode. In case of heating mode, the sound pressure level increases by approximately 1~2 dB.
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
3. Except for the specified combination in the table (26~54HP), there is no other combination of the base unit.
4. The width of outer dimension, it is the value when each distance between the base outdoor units is specified to 20mm.
※ The 11th digit of the model name indicate the power supply of each unit.
U: 460V/60Hz F: 380V/60Hz R: 220V/60Hz

1-40 FAN-2209 201709


GENERAL DATA

Model ※ JTOR440VAE(U,F,R)BS1 JTOR460VAE(U,F,R)BS1 JTOR480VAE(U,F,R)BS1


JTOR220VPE(U,F,R)BS1 JTOR220VPE(U,F,R)BS1 JTOR240VPE(U,F,R)BS1
Combination of Base Unit
JTOR220VPE(U,F,R)BS1 JTOR240VPE(U,F,R)BS1 JTOR240VPE(U,F,R)BS1
Power Supply 3~,460V/60Hz, 3~/N,380V/60Hz, 3~,220V/60Hz
Nominal Cooling Capacity kW 122.0 128.0 136.0
Nominal Heating Capacity kW 140.0 145.0 150.0
Cabinet Color (Munsell Code) Natural Gray (1.0Y 8.5/0.5)
Sound Power Level dB(A) 87 88 89
Sound Pressure Level dB(A) 67 68 69
Outer Dimensions
Height x Width x Depth mm 1,675 x 3,220 x 765 1,675 x 3,220 x 765 1,675 x 3,220 x 765
Net Weight
460V/60Hz kg 374 + 374 374 + 375 375 + 375
380V/60Hz kg 369 + 369 369 + 370 370 + 370
220V/60Hz kg 364 + 364 364 + 365 365 + 365
Gross Weight
460V/60Hz kg 394 + 394 394 + 395 395 + 395
380V/60Hz kg 389 + 389 389 + 390 390 + 390
220V/60Hz kg 384 + 384 384 + 385 385 + 385
Refrigerant R410A
Flow Control Micro-Computer Control Expansion Valve
Compressor Hermetic (Scroll)
DC80PHD + DC80PHD DC80PHD + DC80PHD DC80PHD + DC80PHD
Model + DC80PHD + DC80PHD + DC80PHD + DC80PHD + DC80PHD + DC80PHD
Quantity 4 4 4
Motor Output (Pole) kW 6.7 (6) x 2 + 6.7 (6) x 2 6.7 (6) x 2 + 7.1 (6) x 2 7.1 (6) x 2 + 7.1 (6) x 2
Refrigeration Oil
Type FVC68D
Charge L/Unit 16.8 16.8 16.8
Heat Exchanger Multi-Pass Cross-Finned Tube
Condenser Fan Propeller Fan
Quantity 4 4 4
Air Flow Rate m3/min. 329 x 2 329 + 348 348 x 2
Motor Output (Pole) kW 0.48 (8) x 2 +0.48 (8) x 2 0.48 (8) x 2 + 0.56 (8) x 2 0.56 (8) x 2 + 0.56 (8) x 2
Main Refrigerant Piping
Heat Recovery System (3 Pipes)
Liquid Line mm (in.) 19.05 (3/4) 19.05 (3/4) 19.05 (3/4)
Gas Line
Low Pressure mm (in.) 38.1 (1-1/2) 38.1 (1-1/2) 38.1 (1-1/2)
High/Low Pressure mm (in.) 31.75 (1-1/4) 31.75 (1-1/4) 31.75 (1-1/4)
Refrigerant Charge
kg 22.6 22.9 23.2
(before Shipment)
NOTES:
1. The cooling and heating performances are the values when combined with our specified indoor units.
Cooling Operation Conditions Heating Operation Conditions
Indoor Air Inlet Temperature: 27oC DB (80oF DB) Indoor Air Inlet Temperature: 20oC DB (68oF DB)
o o
19.0 C WB (66.2 F WB) Outdoor Air Inlet Temperature: 7oC DB (45oF DB)
o o
Outdoor Air Inlet Temperature: 35 C DB (95 F DB) 6oC WB (43 oF WB)
Piping Length:12.5 Meters (for JTOR440VAE(U,F,R)BS1) Piping Lift: 0 Meter
15.0 Meters (for JTOR460VAE(U,F,R)BS1 and JTOR480VAE(U,F,R)BS1)
2. The sound pressure is based on the following conditions.
1 Meter from the unit service cover surface, and 1.5 Meters from floor level.
The above data is based on the cooling mode. In case of heating mode, the sound pressure level increases by approximately 1~2 dB.
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
3. Except for the specified combination in the table (26~54HP), there is no other combination of the base unit.
4. The width of outer dimension, it is the value when each distance between the base outdoor units is specified to 20mm.
※ The 11th digit of the model name indicate the power supply of each unit.
U: 460V/60Hz F: 380V/60Hz R: 220V/60Hz

FAN-2209 201709 1-41


GENERAL DATA

Model ※ JTOR500VAE(U,F,R)BS1 JTOR520VAE(U,F,R)BS1 JTOR540VAE(U,F,R)BS1


JTOR140VPE(U,F,R)BS1 JTOR160VPE(U,F,R)BS1 JTOR180VPE(U,F,R)BS1
Combination of Base Unit JTOR180VPE(U,F,R)BS1 JTOR180VPE(U,F,R)BS1 JTOR180VPE(U,F,R)BS1
JTOR180VPE(U,F,R)BS1 JTOR180VPE(U,F,R)BS1 JTOR180VPE(U,F,R)BS1
Power Supply 3~,460V/60Hz, 3~/N,380V/60Hz, 3~,220V/60Hz
Nominal Cooling Capacity kW 140.0 145.0 150.0
Nominal Heating Capacity kW 155.0 160.0 165.0
Cabinet Color (Munsell Code) Natural Gray (1.0Y 8.5/0.5)
Sound Power Level dB(A) 90 90 91
Sound Pressure Level dB(A) 69 69 70
Outer Dimensions
Height x Width x Depth mm 1,675 x 3,670 x 765 1,675 x 3,670 x 765 1,675 x 3,670 x 765
Net Weight
460V/60Hz kg 276 + 320 + 320 319 + 320 + 320 320 + 320 + 320
380V/60Hz kg 271 + 315 + 315 314 + 315 + 315 315 + 315 + 315
220V/60Hz kg 266 + 310 + 310 309 + 310 + 310 310 + 310 + 310
Gross Weight
460V/60Hz kg 294 + 338 + 338 337 + 338 + 338 338 + 338 + 338
380V/60Hz kg 289 + 333+ 333 332 + 333 + 333 333 + 333 + 333
220V/60Hz kg 284 + 328 + 328 327 + 328 + 328 328 + 328 + 328
Refrigerant R410A
Flow Control Micro-Computer Control Expansion Valve
Compressor Hermetic (Scroll)
DC80PHD + AA50PHD + AA50PHD AA50PHD + AA50PHD + AA50PHD AA50PHD + AA50PHD + AA50PHD
Model + AA50PHD + AA50PHD + AA50PHD + AA50PHD + AA50PHD + AA50PHD + AA50PHD + AA50PHD
Quantity 5 6 6
Motor Output (Pole) kW 8.0 (6) x 1 + 5.0 (6) x 2 + 5.0 (6) x 2 4.5 (6) x 2 + 5.0 (6) x 2 + 5.0 (6) x 2 5.0 (6) x 2 + 5.0 (6) x 2 + 5.0 (6) x 2
Refrigeration Oil
Type FVC68D
Charge L/Unit 22.7 23.7 23.7
Heat Exchanger Multi-Pass Cross-Finned Tube
Condenser Fan Propeller Fan
Quantity 6 6 6
Air Flow Rate m3/min. 239 + 256 x 2 256 x 3 256 x 3
Motor Output (Pole) kW 0.33 (8) x 2 + 0.39 (8) x 2 + 0.39 (8) x 2 0.39 (8) x 2 + 0.39 (8) x 2 + 0.39 (8) x 2 0.39 (8) x 2 + 0.39 (8) x 2 + 0.39 (8) x 2
Main Refrigerant Piping
Heat Recovery System (3 Pipes)
Liquid Line mm (in.) 19.05 (3/4) 19.05 (3/4) 19.05 (3/4)
Gas Line
Low Pressure mm (in.) 38.1 (1-1/2) 38.1 (1-1/2) 38.1 (1-1/2)
High/Low Pressure mm (in.) 31.75 (1-1/4) 31.75 (1-1/4) 31.75 (1-1/4)
Refrigerant Charge
kg 30.3 31.3 32.1
(before Shipment)
NOTES:
1. The cooling and heating performances are the values when combined with our specified indoor units.
Cooling Operation Conditions Heating Operation Conditions
Indoor Air Inlet Temperature: 27oC DB (80oF DB) Indoor Air Inlet Temperature: 20oC DB (68oF DB)
o o
19.0 C WB (66.2 F WB) Outdoor Air Inlet Temperature: 7oC DB (45oF DB)
Outdoor Air Inlet Temperature: 35oC DB (95oF DB) 6oC WB (43 oF WB)
Piping Length: 15.0 Meters Piping Lift: 0 Meter
2. The sound pressure is based on the following conditions.
1 Meter from the unit service cover surface, and 1.5 Meters from floor level.
The above data is based on the cooling mode. In case of heating mode, the sound pressure level increases by approximately 1~2 dB.
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
3. Except for the specified combination in the table (26~54HP), there is no other combination of the base unit.
4. The width of outer dimension, it is the value when each distance between the base outdoor units is specified to 20mm.
※ The 11th digit of the model name indicate the power supply of each unit.
U: 460V/60Hz F: 380V/60Hz R: 220V/60Hz

1-42 FAN-2209 201709


GENERAL DATA

2.2 CH-Box

Type Single Branch Multiple Branch

Model Name JCH-AP160SSX JCH-AP280SSX JCH-AP04MSSX JCH-AP08MSSX JCH-AP12MSSX JCH-AP16MSSX

Appearance

Power Supply 1~, 208/230V/60Hz, 220V/60Hz, 1~/N, 220V/60Hz, 220-240V/50Hz

Electrical Power Consumption W 5 5 11.2 22.4 33.6 44.8

Current A 0.1 0.1 0.2 0.4 0.6 0.8

Maximum Total Capacity Index kW 16 28 44.8 85 85 85

Number of Branches(for Indoor Unit) 1 1 4 8 12 16

Maximum Capacity Index per Branch kW - - 16 16 16 16

Maximum Connectable Indoor Units Per Branch 7 8 6 6 6 6


Dimensions
mm 191 x 301 x 214 191 x 301 x 214 260 x 303 x 352 260 x 543 x 352 260 x 783 x 352 260 x 1023 x 352
Height x Width x Depth
Refrigerant R410A
Gas Line mm
15.88 (5/8) 15.88 (5/8) 22.2 (7/8) 22.2 (7/8) 25.4 (1) 28.58 (1-1/8)
(High and Low pressure side) (in.)
Outdoor
Gas Line mm
Unit 19.05 (3/4) 19.05 (3/4) 25.4 (1) 28.58 (1-1/8) 28.58 (1-1/8) 31.75 (1-1/4)
(Suction Gas) (in.)
Side
Refrigerant mm
Liquid Line Not included Not included 12.7 (1/2) 12.7 (1/2) 15.88 (5/8) 19.05 (3/4)
Piping (in.)
mm
Indoor Gas Line 15.88 (5/8) 19.05 (3/4) 15.88 (5/8) 15.88 (5/8) 15.88 (5/8) 15.88 (5/8)
(in.)
Unit
Side mm
Liquid Line Not included Not included 9.52 (3/8) 9.52 (3/8) 9.52 (3/8) 9.52 (3/8)
(in.)
Net Weight kg 6.0 6.0 14.0 25.0 36.0 47.0

FAN-2209 201709 1-43


COMPONENT DATA

3. Component Data

Outdoor Heat Exchanger and Fan

Model ※ JTOR080VPE(U, F, R)BS1 JTOR100VPE(U, F, R)BS1 JTOR120VPE(U, F, R)BS1 JTOR140VPE(U, F, R)BS1 JTOR160VPE(U, F, R)BS1

Heat Exchanger

Type Multi-Pass Cross Finned Tube

Tube Material Copper Tube

Outer Diameter mm 7.0 7.0 7.0 7.0 7.0

Rows 2 2 3 3 3

Number of Tube/Coil 116 116 174 174 174

Fin Material Aluminum

Pitch mm 1.7 1.7 1.7 1.7 1.7

Maximum Operating Pressure MPa 4.15 4.15 4.15 4.15 4.15

Total Face Area m2 2.36 2.36 2.36 3.12 3.12

Number of Coil/Unit 1 1 1 2 2

Outdoor Fan Large Diameter Fan (Propeller Fan)

Number/Unit 1 1 1 2 2

Outer Diameter mm 644 644 644 544 + 544 544 + 544

Revolution rpm 780 804 852 1086 + 1086 1164 + 1164

Nominal Air Flow m3/min. 165 170 190 239 256

Outdoor Fan Motor Drip-Proof Type Enclosure

Starting Method DC Motor

Nominal Output W 260 280 420 330 + 330 390 + 390

Quantity 1 1 1 2 2

Insulation Class E E E E E

※ The 11th digit of the model name indicate the power supply of each unit. U: 460V/60Hz F: 380V/60Hz R: 220V/60Hz

Model ※ JTOR180VPE(U, F, R)BS1 JTOR200VPE(U, F, R)BS1 JTOR220VPE(U, F, R)BS1 JTOR240VPE(U, F, R)BS1 JTOR260VAE(U, F, R)BS1
Heat Exchanger
Type Multi-Pass Cross Finned Tube
Tube Material Copper Tube
Outer Diameter mm 7.0 7.0 7.0 7.0 7.0
Rows 3 3 3 3 3+3
Number of Tube/Coil 174 174 174 174 174 + 174
Fin Material Aluminum
Pitch mm 1.7 1.7 1.7 1.7 1.7
Maximum Operating Pressure MPa 4.15 4.15 4.15 4.15 4.15
Total Face Area m2 3.12 3.58 3.58 3.58 2.36 + 3.12
Number of Coil/Unit 2 2 2 2 3
Outdoor Fan Large Diameter Fan (Propeller Fan)
Number/Unit 2 2 2 2 3
Outer Diameter mm 544 + 544 644 + 644 644 + 644 644 + 644 644 + 544 + 544
Revolution rpm 1164 + 1164 888 + 888 888 + 888 936 + 936 852 + 1086 + 1086
Nominal Air Flow m3/min. 256 329 329 348 190 + 239
Outdoor Fan Motor Drip-Proof Type Enclosure
Starting Method DC Motor
Nominal Output W 390 + 390 480 + 480 480 + 480 560 + 560 420 + 330 + 330
Quantity 2 2 2 2 3
Insulation Class E E E E E+E

※ The 11th digit of the model name indicate the power supply of each unit. U: 460V/60Hz F: 380V/60Hz R: 220V/60Hz

1-44 FAN-2209 201709


COMPONENT DATA

Outdoor Heat Exchanger and Fan

Model ※ JTOR280VAE(U, F, R)BS1 JTOR300VAE(U, F, R)BS1 JTOR320VAE(U, F, R)BS1 JTOR340VAE(U, F, R)BS1 JTOR360VAE(U, F, R)BS1
Heat Exchanger
Type Multi-Pass Cross Finned Tube
Tube Material Copper Tube
Outer Diameter mm 7.0 7.0 7.0 7.0 7.0
Rows 3+3 3+3 3+3 3+3 3+3
Number of Tube/Coil 174 + 174 174 + 174 174 + 174 174 + 174 174 + 174
Fin Material Aluminum
Pitch mm 1.7 1.7 1.7 1.7 1.7
Maximum Operating Pressure MPa 4.15 4.15 4.15 4.15 4.15
Total Face Area m2 2.36 + 3.12 2.36 + 3.12 3.12 + 3.12 3.12 + 3.12 3.12 + 3.12
Number of Coil/Unit 3 3 4 4 4
Outdoor Fan Large Diameter Fan (Propeller Fan)
Number/Unit 3 3 4 4 4
Outer Diameter mm 644 + 544 + 544 644 + 544 + 544 544 + 544 + 544 + 544 544 + 544 + 544 + 544 544 + 544 + 544 + 544
Revolution rpm 852 + 1164 + 1164 852 + 1164 + 1164 1086 + 1086 + 1164 + 1164 1164 + 1164 + 1164 + 1164 1164 + 1164 + 1164 + 1164
Nominal Air Flow m3/min. 190 + 256 190 + 256 239 + 256 256 + 256 256 + 256
Outdoor Fan Motor Drip-Proof Type Enclosure
Starting Method DC Motor
Nominal Output W 420 + 390 + 390 420 + 390 + 390 330 + 330 + 390 + 390 390 + 390 + 390 + 390 390 + 390 + 390 + 390
Quantity 3 3 4 4 4
Insulation Class E+E E+E E+E E+E E+E
※ The 11th digit of the model name indicate the power supply of each unit. U: 460V/60Hz F: 380V/60Hz R: 220V/60Hz

Model ※ JTOR380VAE(U, F, R)BS1 JTOR400VAE(U, F, R)BS1 JTOR420VAE(U, F, R)BS1 JTOR440VAE(U, F, R)BS1 JTOR460VAE(U, F, R)BS1
Heat Exchanger
Type Multi-Pass Cross Finned Tube
Tube Material Copper Tube
Outer Diameter mm 7.0 7.0 7.0 7.0 7.0
Rows 3+ 3 3+3 3+3 3+3 3+3
Number of Tube/Coil 174 + 174 174 + 174 174 + 174 174 + 174 174 + 174
Fin Material Aluminum
Pitch mm 1.7 1.7 1.7 1.7 1.7
Maximum Operating Pressure MPa 4.15 4.15 4.15 4.15 4.15
Total Face Area m2 3.12 + 3.58 3.12 + 3.58 3.12 + 3.58 3.58 + 3.58 3.58 + 3.58
Number of Coil/Unit 4 4 4 4 4
Outdoor Fan Large Diameter Fan (Propeller Fan)
Number/Unit 4 4 4 4 4
Outer Diameter mm 544 + 544 + 644 + 644 544 + 544 + 644 + 644 544 + 544 + 644 + 644 644 + 644 + 644 + 644 644 + 644 + 644 + 644
Revolution rpm 1086 + 1086 + 936 + 936 1164 + 1164 + 888 + 888 1164 + 1164 + 936 + 936 888 + 888 + 888 + 888 888 + 888 + 936 + 936
Nominal Air Flow m3/min. 239 + 348 256 + 329 256 + 348 329 + 329 329 + 348
Outdoor Fan Motor Drip-Proof Type Enclosure
Starting Method DC Motor
Nominal Output W 330 + 330 + 560 + 560 390 + 390 + 480 + 480 390 + 390 + 560 + 560 480 + 480 + 480 + 480 480 + 480 + 560 + 560
Quantity 4 4 4 4 4
Insulation Class E+E E+E E+E E+E E+E
※ The 11th digit of the model name indicate the power supply of each unit. U: 460V/60Hz F: 380V/60Hz R: 220V/60Hz

FAN-2209 201709 1-45


COMPONENT DATA

Outdoor Heat Exchanger and Fan

Model ※ JTOR480VAE(U, F, R)BS1 JTOR500VAE(U, F, R)BS1 JTOR520VAE(U, F, R)BS1 JTOR540VAE(U, F, R)BS1


Heat Exchanger
Type Multi-Pass Cross Finned Tube
Tube Material Copper Tube
Outer Diameter mm 7.0 7.0 7.0 7.0
Rows 3+3 3+3+3 3+3+3 3+3+3
Number of Tube/Coil 174 + 174 174 + 174 + 174 174 + 174 + 174 174 + 174 + 174
Fin Material Aluminum
Pitch mm 1.7 1.7 1.7 1.7
Maximum Operating Pressure MPa 4.15 4.15 4.15 4.15
Total Face Area m2 3.58 + 3.58 3.12 + 3.12 + 3.12 3.12 + 3.12 + 3.12 3.12 + 3.12 + 3.12
Number of Coil/Unit 4 6 6 6
Outdoor Fan Large Diameter Fan (Propeller Fan)
Number/Unit 4 6 6 6
544 + 544 + 544 544 + 544 + 544 544 + 544 + 544
Outer Diameter mm 644 + 644 + 644 + 644
+ 544 + 544 + 544 + 544 + 544 + 544 + 544 + 544 + 544
1086 + 1086 + 1164 1164 + 1164 + 1164 1164 + 1164 + 1164
Revolution rpm 936 + 936 + 936 + 936
+ 1164 + 1164 + 1164 + 1164 + 1164 + 1164 + 1164 + 1164 + 1164
3
Nominal Air Flow m /min. 348 + 348 239 + 256 + 256 256 + 256 + 256 256 + 256 + 256
Outdoor Fan Motor Drip-Proof Type Enclosure
Starting Method DC Motor
330 + 330 + 390 390 + 390 + 390 390 + 390 + 390
Nominal Output W 560 + 560 + 560 + 560
+ 390 + 390 + 390 + 390 + 390 + 390 + 390 + 390 + 390
Quantity 4 6 6 6
Insulation Class E+E E+E+E E+E+E E+E+E
※ The 11th digit of the model name indicate the power supply of each unit. U: 460V/60Hz F: 380V/60Hz R: 220V/60Hz

1-46 FAN-2209 201709


DIMENSIONAL DATA

4. Dimensional Data
4.1 Outdoor Units

Model: JTOR080VPE(U,F,R)BS1, JTOR100VPE(U,F,R)BS1, JTOR120VPE(U,F,R)BS1

Unit: mm

FAN-2209 201709 1-47


DIMENSIONAL DATA

Model: JTOR140VPE(U,F,R)BS1, JTOR160VPE(U,F,R)BS1, JTOR180VPE(U,F,R)BS1

Unit: mm

1-48 FAN-2209 201709


DIMENSIONAL DATA

Model: JTOR200VPE(U,F,R)BS1, JTOR220VPE(U,F,R)BS1, JTOR240VPE(U,F,R)BS1

Unit: mm

FAN-2209 201709 1-49


DIMENSIONAL DATA

4.2 CH-Box
Model: JCH-AP160SSX

Unit: mm

Model: JCH-AP280SSX
Unit: mm

1-50 FAN-2209 201709


DIMENSIONAL DATA

Model: JCH-AP04MSSX

Unit: mm

Model: JCH-AP08MSSX
Unit: mm

FAN-2209 201709 1-51


DIMENSIONAL DATA

Model: JCH-AP12MSSX

Unit: mm

Model: JCH-AP16MSSX

Unit: mm

1-52 FAN-2209 201709


STRUCTURE

5. Structure
5.1 Outdoor Units

Model: JTOR080VPE(U,F,R)BS1, JTOR100VPE(U,F,R)BS1, JTOR120VPE(U,F,R)BS1

Unit: mm

No. Part Name No. Part Name


1 Compressor (Inverter) 13 Check Joint (Low)
2 Heat Exchanger 14 Check Joint (High)
3 Propeller Fan 15 Check Joint (for Oil)
4 Fan Motor 16 Electrical Box
5 Accumulator (Pressure Vessel) 17 Low Pressure Sensor
6 Oil Separator (Not Pressure Vessel) 18 High Pressure Sensor
Micro-Computer Control Expansion Valve 19 High Pressure Switch for Protection
7
(2pcs.) 20 Strainer
8 Reversing Valve (2pcs.) 21 Check Valve
9 Stop Valve (Gas) (Low Pressure) 22 Crankcase Heater (3pcs.)
10 Stop Valve (Gas) (High/Low Pressure) 23 Double Tube Type Heat Exchanger
11 Stop Valve (Liquid) 24 Compressor Cover
12 Solenoid Valve (3pcs.) 25 TB Box (Only 460V/60Hz, 380V/60Hz)

FAN-2209 201709 1-53


STRUCTURE

Model: JTOR140VPE(U,F,R)BS1

Unit: mm

No. Part Name No. Part Name


1 Compressor (Inverter) 13 Check Joint (Low)
2 Heat Exchanger 14 Check Joint (High)
3 Propeller Fan 15 Check Joint (for Oil)
4 Fan Motor 16 Electrical Box
5 Accumulator (Pressure Vessel) 17 Low Pressure Sensor
6 Oil Separator (Not Pressure Vessel) 18 High Pressure Sensor
Micro-Computer Control Expansion Valve 19 High Pressure Switch for Protection
7
(2pcs.) 20 Strainer
8 Reversing Valve (2pcs.) 21 Check Valve
9 Stop Valve (Gas) (Low Pressure) 22 Crankcase Heater (3pcs.)
10 Stop Valve (Gas) (High/Low Pressure) 23 Double Tube Type Heat Exchanger
11 Stop Valve (Liquid) 24 Compressor Cover
12 Solenoid Valve (3pcs.) 25 TB Box (Only 460V/60Hz, 380V/60Hz)

1-54 FAN-2209 201709


STRUCTURE

Model: JTOR160VPE(U,F,R)BS1 and JTOR180VPE(U,F,R)BS1

Unit: mm

No. Part Name No. Part Name


1 Compressor (2 Inverters) 13 Check Joint (Low)
2 Heat Exchanger 14 Check Joint (High)
3 Propeller Fan 15 Check Joint (for Oil)
4 Fan Motor 16 Electrical Box
5 Accumulator (Pressure Vessel) 17 Low Pressure Sensor
6 Oil Separator (Not Pressure Vessel) 18 High Pressure Sensor
Micro-Computer Control Expansion Valve 19 High Pressure Switch for Protection (2pcs.)
7
(2pcs.) 20 Strainer
8 Reversing Valve (2pcs.) 21 Check Valve
9 Stop Valve (Gas) (Low Pressure) 22 Crankcase Heater (6pcs.)
10 Stop Valve (Gas) (High/Low Pressure) 23 Double Tube Type Heat Exchanger
11 Stop Valve (Liquid) 24 Compressor Cover
12 Solenoid Valve (3pcs.) 25 TB Box (Only 460V/60Hz, 380V/60Hz)

FAN-2209 201709 1-55


STRUCTURE

Model: JTOR200VPE(U,F,R)BS1, JTOR220VPE(U,F,R)BS1 and JTOR240VPE(U,F,R)BS1

Unit: mm

No. Part Name No. Part Name


1 Compressor (2 Inverters) 13 Check Joint (Low)
2 Heat Exchanger 14 Check Joint (High)
3 Propeller Fan 15 Check Joint (for Oil)
4 Fan Motor 16 Electrical Box
5 Accumulator (Pressure Vessel) 17 Low Pressure Sensor
6 Oil Separator (Not Pressure Vessel) 18 High Pressure Sensor
Micro-Computer Control Expansion Valve 19 High Pressure Switch for Protection (2pcs.)
7
(3pcs.) 20 Strainer
8 Reversing Valve (2pcs.) 21 Check Valve
9 Stop Valve (Gas) (Low Pressure) 22 Crankcase Heater (6pcs.)
10 Stop Valve (Gas) (High/Low Pressure) 23 Double Tube Type Heat Exchanger
11 Stop Valve (Liquid) 24 Compressor Cover
12 Solenoid Valve (3pcs.) 25 TB Box (Only 460V/60Hz, 380V/60Hz)

1-56 FAN-2209 201709


STRUCTURE

5.2 CH-Box

Model: JCH-AP160SSX
Unit: mm

Model: JCH-AP280SSX

Unit: mm

FAN-2209 201709 1-57


STRUCTURE

Model: JCH-AP04MSSX
Unit: mm

Model: JCH-AP08MSSX
Unit: mm

1-58 FAN-2209 201709


STRUCTURE

Model: JCH-AP12MSSX
Unit: mm

Model: JCH-AP16MSSX
Unit: mm

FAN-2209 201709 1-59


SELECTION DATA

6. Selection Data
6.1 Selection Guide
(1) Meaning of Model Name of Indoor Unit
Example J T KF 028 H0 P S A Q

Factory
Q: Quigdao, China
S: Shimizu, Japan
Generation
Power Supply
S: 220~240V/50Hz
220V/60Hz
Drain Pump
P: with Drain Pump
Heater
0: Not Equipped
Capacity
kW x 10
Indoor Unit Type
Market Position
T: Tier-1 Commercial VRF
Brand
J: York Brand

Unit Type
NOTE:
In-the-Ceiling Type (High Static) DH Select the indoor units and outdoor unit
In-the-Ceiling Type (Middle Static) DM so that the total indoor unit horsepower is
In-the-Ceiling Type (Low Static) DL near to the outdoor unit horsepower.
4-Way Cassette Type KF
4-Way Cassette Compact Type KM
2-Way Cassette Type KT
Wall Type HW
Floor Concealed Type FC
Ceiling Type CS

1-60 FAN-2209 201709


SELECTION DATA

(2) Nominal Capacity of Indoor Units


Horsepower
(HP) 0.4 0.6 0.8 1.0 1.5 2.0 2.5 3.0 4.0 5.0 6.0 8.0 10.0
Capacity
kW 1.1 1.6 2.2 2.8 4.0 5.6 7.1 8.0 11.2 14.0 16.0 22.4 28.0
Cooling
kcal/h 900 1,400 1,900 2,400 3,400 4,800 6,100 6,900 9,600 12,000 13,800 19,300 24,100
Capacity
Btu/h 3,700 5,500 7,500 9,600 13,600 19,100 24,200 27,300 38,200 47,800 54,600 76,400 95,500
kW 1.3 1.9 2.5 3.2 4.8 6.3 8.5 9.0 12.5 16.0 18.0 25.0 31.5
Heating
kcal/h 1,100 1,600 2,200 2,800 4,100 5,400 7,300 7,700 10,800 13,800 15,500 21,500 27,100
Capacity
Btu/h 4,400 6,500 8,500 10,900 16,400 21,500 29,000 30,700 42,600 54,600 61,400 85,300 107,500

Capacity Adjustment by Dip Switch Setting

Horsepower (HP) 1.3 1.8 2.3


Variable Capacity 1.3 1.5 1.8 2.0 2.3 2.5
kW 3.8 5.2 6.7
Cooling
kcal/h 3,300 4,500 5,800
Capacity
Btu/h 13,000 17,800 22,900
kW 4.2 5.6 7.5
Heating
kcal/h 3,600 4,800 6,500
Capacity
Btu/h 14,300 19,100 25,600
Applicable Model DH, KF, KT, HW, FC DH, KF, KT, HW, CS DH, KF, KT, CS

1.3HP 1.5HP 1.8HP 2.0HP 2.3HP 2.5HP


Indoor Unit ON ON ON ON ON ON
Dip Switch
Setting
1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4
(DSW3)
Lowered Standard Lowered Standard Lowered Standard

FAN-2209 201709 1-61


SELECTION DATA

(3) Meaning of Model Name of Outdoor Unit

J T O R 080 V P E R B S 1

Version
Factory
S: Shimizu, Japan
Generation
Power Supply
U: 3~, 460V/60Hz
F: 3~/N, 380V/60Hz
R: 3~, 220V/60Hz
Refrigerant
E: R410A
Module and Combination
A: All Inverter Combination
P: All Inverter Module
Air Discharge
V: Vertical
Capacity
HP x 10 (Example: 080 = 8HP)
Application
R: Heat Recovery
Heat Source
O: Air Source
Market Position
T: Tier-1 Commercial VRF
Brand
J: York Brand

1-62 FAN-2209 201709


SELECTION DATA

(4) Nominal Capacity of Outdoor Unit

Horsepower (HP) 8 10 12 14 16 18
kW 22.4 28.0 33.5 40.0 45.0 50.0
Cooling
kcal/h 19,300 24,100 28,800 34,400 38,700 43,000
Capacity
Btu/h 76,400 95,500 114,300 136,500 153,500 170,600
kW 25.0 31.5 37.5 45.0 50.0 56.0
Heating
kcal/h 21,500 27,100 32,200 38,700 43,000 48,100
Capacity
Btu/h 85,300 107,500 128,000 153,500 170,600 191,100

Horsepower (HP) 20 22 24 26 28 30
kW 56.0 61.5 67.0 73.0 77.5 85.0
Cooling
kcal/h 48,100 52,800 57,600 62,700 66,600 73,100
Capacity
Btu/h 191,100 210,000 228,600 249,100 264,400 290,000
kW 63.0 69.0 77.5 82.5 90.0 95.0
Heating
kcal/h 54,100 59,300 66,600 70,900 77,400 81,700
Capacity
Btu/h 215,000 235,000 264,400 281,500 307,100 324,200

Horsepower (HP) 32 34 36 38 40 42
kW 90.0 95.0 100.0 106.0 112.0 118.0
Cooling
kcal/h 77,400 81,700 86,000 91,200 96,300 101,500
Capacity
Btu/h 307,100 324,200 341,200 361,700 382,200 402,600
kW 100.0 106.0 112.0 118.0 125.0 132.0
Heating
kcal/h 86,000 91,200 96,300 101,500 107,600 113,600
Capacity
Btu/h 341,200 361,700 382,200 402,600 426,500 450,400

Horsepower (HP) 44 46 48 50 52 54
kW 122.0 128.0 136.0 140.0 145.0 150.0
Cooling
kcal/h 104,900 110,100 117,000 120,400 124,700 129,000
Capacity
Btu/h 416,400 436,800 464,000 477,700 494,700 511,800
kW 140.0 145.0 150.0 155.0 160.0 165.0
Heating
kcal/h 120,400 124,700 129,000 133,300 137,600 141,900
Capacity
Btu/h 477,700 494,700 511,800 528,800 545,900 563,000

Nominal Capacity of Outdoor Unit is under the condition that the total indoor unit horsepower is the same
as outdoor unit horsepower.

(5) Outdoor Unit Capacity at Nominal Temperature


If the total indoor unit horsepower is not the same as the outdoor unit horsepower, refer to the item 6.2
"Capacity Characteristic Curve".

FAN-2209 201709 1-63


SELECTION DATA

(6) Given Condition (Example)

Total Load for Each Room


Item Room (1) Room (2) Room (3) Room (4)
Estimated kW 4.24 5.35 5.35 6.36
Cooling Load kcal/h 3,650 4,600 4,600 5,472
Estimated kW 4.77 6.00 6.00 7.16
Heating Load kcal/h 4,100 5,160 5,160 6,160

Item Room (5) Room (6) Room (7)


Estimated kW 8.48 10.6 10.6
Cooling Load kcal/h 7,295 9,119 9,119
Estimated kW 9.54 11.9 11.9
Heating Load kcal/h 8,207 10,238 10,238

Temperature Condition
Cooling Heating
Outdoor Coil Air Inlet Outdoor Coil Air Inlet
Dry Bulb: 30oC Dry Bulb: 1oC
Indoor Coil Air Inlet Wet Bulb: 0oC
Dry Bulb: 27oC Indoor Coil Air Inlet
Wet Bulb: 19oC Dry Bulb: 20oC

< Heat Recovery System (3 Pipes) >


Equivalent Piping Length between Indoor Units and Outdoor Unit: 60m
Piping Lift: 20m
(Gas Piping Size: Normal, Refer to the item 6.7 “Correction Factor According to Piping Length”)
Correction Factor of Cooling Capacity = 0.90
Correction Factor of Heating Capacity = 0.96
Power Source: 60Hz

(7) Selecting Matching Indoor Units and Nominal Capacity

Select In-the-Ceiling Type Indoor Units (Example)


Item Room (1) Room (2) Room (3) Room (4) Room (5)
Selected Model IDU-2HP IDU-2.5HP IDU-2.5HP IDU-2.5HP IDU-4.0HP
Nominal kW 5.6 7.1 7.1 8.0 11.2
Cooling Capacity kcal/h 4,800 6,100 6,100 6,900 9,600
Nominal kW 6.3 8.5 8.5 9.0 12.5
Heating Capacity kcal/h 5,400 7,300 7,300 7,700 10,700

(1)+(2)+(3)+(4)
Item Room (6) Room (7) Outdoor
+(5)+(6)+(7)
Selected Model IDU-5.0HP IDU-5.0HP - ODU-22HP
Nominal kW 14.0 14.0 67.0 61.5
Cooling Capacity kcal/h 12,000 12,000 57,500 52,800
Nominal kW 16.0 16.0 76.8 69.0
Heating Capacity kcal/h 13,800 13,800 66,000 59,300

1-64 FAN-2209 201709


SELECTION DATA

(8) Actual Capacity


In the case of the example, the total indoor horsepower is 24HP
(=2.0HP+2.5HPx2+3.0HP+4.0HP+5.0HPx2).
Therefore, the outdoor unit capacity at the nominal temperature selected from the “Capacity Characteristic
Curve” is 61.5kW (52,890kcal/h) at the cooling operation, 69.0kW (59,340kcal/h) at
the heating operation under nominal conditions.

a) Actual Capacity of Outdoor Unit


Maximum Actual Capacity of Outdoor Unit
= [Outdoor Unit Capacity at Nominal Temperature
x Correction Factor According to Total Indoor Unit Capacity] (*1)
x Correction Factor According to Piping Length and Lift (*2)
x Correction Factor According to Temperature Condition (*3)
x Correction Factor According to Defrosting Operation (*4)
x Correction Factor According to Altitude (*5)

(*1): Refer to the table in item 6.2 for Correction Factor according to the total indoor unit capacity.
(*2): Refer to the table in item 6.4 “Correction Factor According to Piping Length”.
(*3): Refer to the table in item 6.3 for Correction Factor according to the temperature condition.
(*4): Refer to the table in item 6.5 “Correction Factor According to Defrosting Operation”.
(*5): Refer to the table in item 6.6 “Correction Factor According to Altitude”.

Actual Capacity of Outdoor Unit is


Cooling: [61.5kW (52,890kcal/h)] x 0.90 x 1.00 = 55.4kW (47,600kcal/h)
Heating: [69.0kW (59,340kcal/h)] x 0.96 x 0.91 x 1.00 = 59.6kW (51,270kcal/h)

b) Actual Capacity of Each Indoor Unit


Actual Capacity of Each Indoor Unit
= Actual Capacity of Outdoor Unit
x [Each Indoor Unit's Horsepower ÷ Summation of Each Indoor Unit Horsepower]

ex.
<IDU-2.0HP>
Cooling Capacity: 55.4x(2.0[HP]÷(2.0[HP]+2.5[HP]x2+3.0[HP]+4.0[HP]+5.0[HP]x2))=4.62kW (3,967kcal/h)
Heating Capacity: 59.6x(2.0[HP]÷(2.0[HP]+2.5[HP]x2+3.0[HP]+4.0[HP]+5.0[HP]x2))=4.97kW (4,273kcal/h)
<IDU-2.5HP>
Cooling Capacity: 55.4x(2.5[HP]÷(2.0[HP]+2.5[HP]x2+3.0[HP]+4.0[HP]+5.0[HP]x2))=5.77kW (4,958kcal/h)
Heating Capacity: 59.6x(2.5[HP]÷(2.0[HP]+2.5[HP]x2+3.0[HP]+4.0[HP]+5.0[HP]x2))=6.21kW (5,341kcal/h)
<IDU-3.0HP>
Cooling Capacity: 55.4x(3.0[HP]÷(2.0[HP]+2.5[HP]x2+3.0[HP]+4.0[HP]+5.0[HP]x2))=6.93kW (5,950kcal/h)
Heating Capacity: 59.6x(3.0[HP]÷(2.0[HP]+2.5[HP]x2+3.0[HP]+4.0[HP]+5.0[HP]x2))=7.45kW (6,409kcal/h)
<IDU-4.0HP>
Cooling Capacity: 55.4x(4.0[HP]÷(2.0[HP]+2.5[HP]x2+3.0[HP]+4.0[HP]+5.0[HP]x2))=9.23kW (7,933kcal/h)
Heating Capacity: 59.6x(4.0[HP]÷(2.0[HP]+2.5[HP]x2+3.0[HP]+4.0[HP]+5.0[HP]x2))=9.93kW (8,545kcal/h)
<IDU-5.0HP>
Cooling Capacity: 55.4x(5.0[HP]÷(2.0[HP]+2.5[HP]x2+3.0[HP]+4.0[HP]+5.0[HP]x2))=11.54kW (9,917kcal/h)
Heating Capacity: 59.6x(5.0[HP]÷(2.0[HP]+2.5[HP]x2+3.0[HP]+4.0[HP]+5.0[HP]x2))=12.42kW (10,681kcal/h)

FAN-2209 201709 1-65


SELECTION DATA

< Result >


Item Room (1) Room (2) Room (3) Room (4)
Selected Model IDU-2HP IDU-2.5HP IDU-2.5HP IDU-3.0HP
Actual Maximum kW 4.62 5.77 5.77 6.93
Actual Cooling Capacity kcal/h 3,967 4,958 4,958 5,950
Capacity Actual Maximum kW 4.97 6.21 6.21 7.45
Heating Capacity kcal/h 4,273 5,341 5,341 6,409
Estimated kW 4.24 5.35 5.35 6.36
Design Cooling Load kcal/h 3,650 4,600 4,600 5,472
Load Estimated kW 4.77 6.00 6.00 7.16
Heating Load kcal/h 4,100 5,160 5,160 6,160

(1)+(2)+(3)+(4)
Item Room (5) Room (6) Room (7)
+(5)+(6)+(7)
Selected Model IDU-4.0HP IDU-5.0HP IDU-5.0HP -
Actual Maximum kW 9.23 11.54 11.54 55.40
Actual Cooling Capacity kcal/h 7,933 9,917 9,917 47,600
Capacity Actual Maximum kW 9.93 12.42 12.42 59.61
Heating Capacity kcal/h 8,545 10,681 10,681 51,271
Estimated kW 8.48 10.6 10.6 50.98
Design Cooling Load kcal/h 7,295 9,119 9,119 43,855
Load Estimated kW 9.54 11.9 11.9 57.27
Heating Load kcal/h 8,207 10,238 10,238 49,263

1-66 FAN-2209 201709


SELECTION DATA

6.2 Capacity Characteristic Curve


The following charts show the characteristics of outdoor unit capacity which corresponds with total
horsepower of combined indoor unit, on standard condition with horizontal refrigerant piping of 7.5m in
length.

[ Standard Type ]

< Cooling Capacity >


• Condition
Indoor Air Inlet Temperature: 27.0oC DB (80.0oF DB), 19.0oC WB (66.2oF WB)
Outdoor Air Inlet Temperature: 35.0oC DB (95.0oF DB)
A x 1.06
A x 1.03
A
Cooling Capacity (kW)

A x 0.50

0 B x 0.50 B B x 1.03 B x 1.30

Standard Capacity
Allowable Capacity

Total Horsepower of Combined Indoor Units (HP)

Outdoor Unit (HP) A (kW) B (HP) Outdoor Unit (HP) A (kW) B (HP)
8 22.4 8 26 73.0 26
10 28.0 10 28 77.5 28
12 33.5 12 32 90.0 32
14 40.0 14 34 95.0 34
16 45.0 16 50 140.0 50
20 56.0 20

A x 1.03
A
Cooling Capacity (kW)

A x 0.50

0 B x 0.50 B B x 1.30

Standard Capacity
Allowable Capacity

Total Horsepower of Combined Indoor Units (HP)

Outdoor Unit (HP) A (kW) B (HP) Outdoor Unit (HP) A (kW) B (HP)
18 50.0 18 42 118.0 42
22 61.5 22 44 122.0 44
24 67.0 24 46 128.0 46
30 85.0 30 48 136.0 48
36 100.0 36 52 145.0 52
38 106.0 38 54 150.0 54
40 112.0 40

FAN-2209 201709 1-67


SELECTION DATA

< Heating Capacity >


• Condition
Indoor Air Inlet Temperature: 20.0oC DB (68.0oF DB)
Outdoor Air Inlet Temperature: 7.0oC DB (45.0oF DB), 6.0oC WB (43.0oF WB)

A x 1.04
A x 1.03
A
Heating Capacity (kW)

A x 0.50

0 B x 0.50 B B x 1.03 B x 1.30

Standard Capacity
Allowable Capacity

Total Horsepower of Combined Indoor Units (HP)

Outdoor Unit (HP) A (kW) B (HP) Outdoor Unit (HP) A (kW) B (HP)
8 25.0 8 26 82.5 26
10 31.5 10 28 90.0 28
12 37.5 12 32 100.0 32
14 45.0 14 34 106.0 34
16 50.0 16 50 155.0 50
20 56.0 18

A x 1.02
A
Heating Capacity (kW)

A x 0.50

0 B x 0.50 B B x 1.30

Standard Capacity
Allowable Capacity

Total Horsepower of Combined Indoor Units (HP)

Outdoor Unit (HP) A (kW) B (HP) Outdoor Unit (HP) A (kW) B (HP)
18 56.0 18 40 125.0 40
22 69.0 22 42 132.0 42
24 77.5 24 44 140.0 44
30 95.0 30 46 145.0 46
36 112.0 36 48 150.0 48
38 118.0 38 54 165.0 54

1-68 FAN-2209 201709


SELECTION DATA

The following 41 tables show the examples of outdoor unit capacity which corresponds with total
horsepower of combined indoor unit, according to the item 6.2 "Capacity Characteristic Curve".

Table 1. Outdoor Unit Capacity (JTOR080~120VPE(U,F,R)BS1) with Total Horsepower of Combined Indoor Unit (1)
Total Outdoor Unit Capacity: kW (×1000kcal/h)
RAS-8FSXNS
JTOR080VPE(U,F,R)BS1 RAS-10FSXNS
JTOR100VPE(U,F,R)BS1 RAS-12FSXNS
JTOR120VPE(U,F,R)BS1
Cooling Heating Cooling Heating Cooling Heating
4.0 11.20 ( 9.63 ) 12.50 ( 10.75 )
4.1 11.48 ( 9.87 ) 12.81 ( 11.02 )
4.2 11.76 ( 10.11 ) 13.13 ( 11.29 )
4.3 12.04 ( 10.35 ) 13.44 ( 11.55 )
4.4 12.32 ( 10.59 ) 13.75 ( 11.82 )
_
4.5 12.60 ( 10.83 ) 14.06 ( 12.09 )
4.6 12.88 ( 11.07 ) 14.38 ( 12.36 )
4.7 13.16 ( 11.32 ) 14.69 ( 12.63 )
4.8 13.44 ( 11.56 ) 15.00 ( 12.90 )
4.9 13.72 ( 11.80 ) 15.31 ( 13.17 )
_
5.0 14.00 ( 12.04 ) 15.63 ( 13.44 ) 14.00 ( 12.04 ) 15.75 ( 13.54 )
5.1 14.28 ( 12.28 ) 15.94 ( 13.70 ) 14.28 ( 12.28 ) 16.07 ( 13.81 )
5.2 14.56 ( 12.52 ) 16.25 ( 13.97 ) 14.56 ( 12.52 ) 16.38 ( 14.08 )
5.3 14.84 ( 12.76 ) 16.56 ( 14.24 ) 14.84 ( 12.76 ) 16.70 ( 14.36 )
5.4 15.12 ( 13.00 ) 16.88 ( 14.51 ) 15.12 ( 13.00 ) 17.01 ( 14.63 )
5.5 15.40 ( 13.24 ) 17.19 ( 14.78 ) 15.40 ( 13.24 ) 17.33 ( 14.90 )
5.6 15.68 ( 13.48 ) 17.50 ( 15.05 ) 15.68 ( 13.48 ) 17.64 ( 15.17 )
5.7 15.96 ( 13.72 ) 17.81 ( 15.32 ) 15.96 ( 13.72 ) 17.96 ( 15.44 )
5.8 16.24 ( 13.96 ) 18.13 ( 15.58 ) 16.24 ( 13.96 ) 18.27 ( 15.71 )
5.9 16.52 ( 14.20 ) 18.44 ( 15.85 ) 16.52 ( 14.20 ) 18.59 ( 15.98 )
6.0 16.80 ( 14.45 ) 18.75 ( 16.12 ) 16.80 ( 14.45 ) 18.90 ( 16.25 ) 16.75 ( 14.40 ) 18.75 ( 16.12 )
6.1 17.08 ( 14.69 ) 19.06 ( 16.39 ) 17.08 ( 14.69 ) 19.22 ( 16.52 ) 17.03 ( 14.64 ) 19.06 ( 16.39 )
6.2 17.36 ( 14.93 ) 19.38 ( 16.66 ) 17.36 ( 14.93 ) 19.53 ( 16.79 ) 17.31 ( 14.88 ) 19.38 ( 16.66 )
6.3 17.64 ( 15.17 ) 19.69 ( 16.93 ) 17.64 ( 15.17 ) 19.85 ( 17.06 ) 17.59 ( 15.12 ) 19.69 ( 16.93 )
6.4 17.92 ( 15.41 ) 20.00 ( 17.20 ) 17.92 ( 15.41 ) 20.16 ( 17.33 ) 17.87 ( 15.36 ) 20.00 ( 17.20 )
6.5 18.20 ( 15.65 ) 20.31 ( 17.47 ) 18.20 ( 15.65 ) 20.48 ( 17.61 ) 18.15 ( 15.60 ) 20.31 ( 17.47 )
6.6 18.48 ( 15.89 ) 20.63 ( 17.73 ) 18.48 ( 15.89 ) 20.79 ( 17.88 ) 18.43 ( 15.84 ) 20.63 ( 17.73 )
6.7 18.76 ( 16.13 ) 20.94 ( 18.00 ) 18.76 ( 16.13 ) 21.11 ( 18.15 ) 18.70 ( 16.08 ) 20.94 ( 18.00 )
6.8 19.04 ( 16.37 ) 21.25 ( 18.27 ) 19.04 ( 16.37 ) 21.42 ( 18.42 ) 18.98 ( 16.32 ) 21.25 ( 18.27 )
6.9 19.32 ( 16.61 ) 21.56 ( 18.54 ) 19.32 ( 16.61 ) 21.74 ( 18.69 ) 19.26 ( 16.56 ) 21.56 ( 18.54 )
7.0 19.60 ( 16.85 ) 21.88 ( 18.81 ) 19.60 ( 16.85 ) 22.05 ( 18.96 ) 19.54 ( 16.80 ) 21.88 ( 18.81 )
7.1 19.88 ( 17.09 ) 22.19 ( 19.08 ) 19.88 ( 17.09 ) 22.37 ( 19.23 ) 19.82 ( 17.04 ) 22.19 ( 19.08 )
7.2 20.16 ( 17.33 ) 22.50 ( 19.35 ) 20.16 ( 17.33 ) 22.68 ( 19.50 ) 20.10 ( 17.28 ) 22.50 ( 19.35 )
7.3 20.44 ( 17.58 ) 22.81 ( 19.62 ) 20.44 ( 17.58 ) 23.00 ( 19.77 ) 20.38 ( 17.52 ) 22.81 ( 19.62 )
7.4 20.72 ( 17.82 ) 23.13 ( 19.88 ) 20.72 ( 17.82 ) 23.31 ( 20.04 ) 20.66 ( 17.76 ) 23.13 ( 19.88 )
7.5 21.00 ( 18.06 ) 23.44 ( 20.15 ) 21.00 ( 18.06 ) 23.63 ( 20.31 ) 20.94 ( 18.00 ) 23.44 ( 20.15 )
7.6 21.28 ( 18.30 ) 23.75 ( 20.42 ) 21.28 ( 18.30 ) 23.94 ( 20.58 ) 21.22 ( 18.24 ) 23.75 ( 20.42 )
7.7 21.56 ( 18.54 ) 24.06 ( 20.69 ) 21.56 ( 18.54 ) 24.26 ( 20.86 ) 21.50 ( 18.48 ) 24.06 ( 20.69 )
7.8 21.84 ( 18.78 ) 24.38 ( 20.96 ) 21.84 ( 18.78 ) 24.57 ( 21.13 ) 21.78 ( 18.72 ) 24.38 ( 20.96 )
7.9 22.12 ( 19.02 ) 24.69 ( 21.23 ) 22.12 ( 19.02 ) 24.89 ( 21.40 ) 22.05 ( 18.96 ) 24.69 ( 21.23 )
8.0 22.40 ( 19.26 ) 25.00 ( 21.50 ) 22.40 ( 19.26 ) 25.20 ( 21.67 ) 22.33 ( 19.20 ) 25.00 ( 21.50 )
8.1 22.68 ( 19.50 ) 25.31 ( 21.76 ) 22.68 ( 19.50 ) 25.52 ( 21.94 ) 22.61 ( 19.44 ) 25.31 ( 21.76 )
8.2 22.96 ( 19.74 ) 25.63 ( 22.03 ) 22.96 ( 19.74 ) 25.83 ( 22.21 ) 22.89 ( 19.68 ) 25.63 ( 22.03 )
8.3 23.09 ( 19.85 ) 25.76 ( 22.15 ) 23.24 ( 19.98 ) 26.15 ( 22.48 ) 23.17 ( 19.92 ) 25.94 ( 22.30 )
8.4 23.12 ( 19.88 ) 25.77 ( 22.16 ) 23.52 ( 20.22 ) 26.46 ( 22.75 ) 23.45 ( 20.16 ) 26.25 ( 22.57 )
8.5 23.15 ( 19.91 ) 25.78 ( 22.17 ) 23.80 ( 20.46 ) 26.78 ( 23.02 ) 23.73 ( 20.40 ) 26.56 ( 22.84 )
8.6 23.18 ( 19.93 ) 25.79 ( 22.18 ) 24.08 ( 20.71 ) 27.09 ( 23.29 ) 24.01 ( 20.64 ) 26.87 ( 23.11 )
8.7 23.22 ( 19.96 ) 25.80 ( 22.19 ) 24.36 ( 20.95 ) 27.41 ( 23.56 ) 24.29 ( 20.88 ) 27.19 ( 23.38 )
8.8 23.25 ( 19.99 ) 25.81 ( 22.20 ) 24.64 ( 21.19 ) 27.72 ( 23.83 ) 24.57 ( 21.12 ) 27.50 ( 23.65 )
8.9 23.28 ( 20.01 ) 25.83 ( 22.21 ) 24.92 ( 21.43 ) 28.04 ( 24.11 ) 24.85 ( 21.36 ) 27.81 ( 23.91 )
9.0 23.31 ( 20.04 ) 25.84 ( 22.22 ) 25.20 ( 21.67 ) 28.35 ( 24.38 ) 25.12 ( 21.60 ) 28.12 ( 24.18 )
9.1 23.34 ( 20.07 ) 25.85 ( 22.23 ) 25.48 ( 21.91 ) 28.67 ( 24.65 ) 25.40 ( 21.84 ) 28.44 ( 24.45 )
9.2 23.37 ( 20.10 ) 25.86 ( 22.24 ) 25.76 ( 22.15 ) 28.98 ( 24.92 ) 25.68 ( 22.08 ) 28.75 ( 24.72 )
9.3 23.40 ( 20.12 ) 25.87 ( 22.25 ) 26.04 ( 22.39 ) 29.30 ( 25.19 ) 25.96 ( 22.32 ) 29.06 ( 24.99 )
9.4 23.43 ( 20.15 ) 25.88 ( 22.26 ) 26.32 ( 22.63 ) 29.61 ( 25.46 ) 26.24 ( 22.56 ) 29.37 ( 25.26 )
9.5 23.46 ( 20.18 ) 25.90 ( 22.27 ) 26.60 ( 22.87 ) 29.93 ( 25.73 ) 26.52 ( 22.80 ) 29.69 ( 25.53 )
9.6 23.50 ( 20.20 ) 25.91 ( 22.28 ) 26.88 ( 23.11 ) 30.24 ( 26.00 ) 26.80 ( 23.04 ) 30.00 ( 25.80 )
9.7 23.53 ( 20.23 ) 25.92 ( 22.29 ) 27.16 ( 23.35 ) 30.56 ( 26.27 ) 27.08 ( 23.28 ) 30.31 ( 26.06 )
9.8 23.56 ( 20.26 ) 25.93 ( 22.30 ) 27.44 ( 23.59 ) 30.87 ( 26.54 ) 27.36 ( 23.52 ) 30.62 ( 26.33 )
9.9 23.59 ( 20.28 ) 25.94 ( 22.31 ) 27.72 ( 23.83 ) 31.19 ( 26.81 ) 27.64 ( 23.76 ) 30.94 ( 26.60 )

FAN-2209 201709 1-69


SELECTION DATA

Table 2. Outdoor Unit Capacity (JTOR080~120VPE(U,F,R)BS1) with Total Horsepower of Combined Indoor Unit (2)
Total Outdoor Unit Capacity: kW (×1000kcal/h)
RAS-8FSXNS
JTOR080VPE(U,F,R)BS1 RAS-10FSXNS
JTOR100VPE(U,F,R)BS1 RAS-12FSXNS
JTOR120VPE(U,F,R)BS1
Cooling Heating Cooling Heating Cooling Heating
10.0 23.62 ( 20.31 ) 25.95 ( 22.32 ) 28.00 ( 24.08 ) 31.50 ( 27.09 ) 27.92 ( 24.00 ) 31.25 ( 26.87 )
10.1 23.65 ( 20.34 ) 25.97 ( 22.33 ) 28.28 ( 24.32 ) 31.82 ( 27.36 ) 28.20 ( 24.24 ) 31.56 ( 27.14 )
10.2 23.68 ( 20.36 ) 25.98 ( 22.34 ) 28.56 ( 24.56 ) 32.13 ( 27.63 ) 28.48 ( 24.48 ) 31.88 ( 27.41 )
10.3 23.71 ( 20.39 ) 25.99 ( 22.35 ) 28.84 ( 24.80 ) 32.45 ( 27.90 ) 28.75 ( 24.72 ) 32.19 ( 27.68 )
10.4 23.74 ( 20.42 ) 26.00 ( 22.36 ) 28.87 ( 24.82 ) 32.46 ( 27.91 ) 29.03 ( 24.96 ) 32.50 ( 27.94 )
10.5 28.90 ( 24.85 ) 32.47 ( 27.92 ) 29.31 ( 25.20 ) 32.81 ( 28.21 )
10.6 28.93 ( 24.88 ) 32.48 ( 27.93 ) 29.59 ( 25.44 ) 33.13 ( 28.48 )
10.7 28.96 ( 24.90 ) 32.49 ( 27.94 ) 29.87 ( 25.68 ) 33.44 ( 28.75 )
10.8 29.00 ( 24.93 ) 32.50 ( 27.95 ) 30.15 ( 25.92 ) 33.75 ( 29.02 )
10.9 29.03 ( 24.96 ) 32.52 ( 27.96 ) 30.43 ( 26.16 ) 34.06 ( 29.29 )
11.0 29.06 ( 24.99 ) 32.53 ( 27.97 ) 30.71 ( 26.40 ) 34.38 ( 29.56 )
11.1 29.09 ( 25.01 ) 32.54 ( 27.98 ) 30.99 ( 26.64 ) 34.69 ( 29.83 )
11.2 29.12 ( 25.04 ) 32.55 ( 27.99 ) 31.27 ( 26.88 ) 35.00 ( 30.09 )
11.3 29.15 ( 25.07 ) 32.56 ( 28.00 ) 31.55 ( 27.12 ) 35.31 ( 30.36 )
11.4 29.18 ( 25.09 ) 32.57 ( 28.01 ) 31.83 ( 27.36 ) 35.63 ( 30.63 )
11.5 29.21 ( 25.12 ) 32.59 ( 28.02 ) 32.10 ( 27.60 ) 35.94 ( 30.90 )
11.6 29.24 ( 25.15 ) 32.60 ( 28.03 ) 32.38 ( 27.84 ) 36.25 ( 31.17 )
11.7 29.28 ( 25.17 ) 32.61 ( 28.04 ) 32.66 ( 28.08 ) 36.56 ( 31.44 )
11.8 29.31 ( 25.20 ) 32.62 ( 28.05 ) 32.94 ( 28.32 ) 36.88 ( 31.71 )
11.9 29.34 ( 25.23 ) 32.63 ( 28.06 ) 33.22 ( 28.56 ) 37.19 ( 31.98 )
12.0 29.37 ( 25.25 ) 32.64 ( 28.07 ) 33.50 ( 28.80 ) 37.50 ( 32.24 )
12.1 29.40 ( 25.28 ) 32.66 ( 28.08 ) 33.78 ( 29.04 ) 37.81 ( 32.51 )
12.2 29.43 ( 25.31 ) 32.67 ( 28.09 ) 34.06 ( 29.28 ) 38.13 ( 32.78 )
12.3 29.46 ( 25.33 ) 32.68 ( 28.10 ) 34.34 ( 29.52 ) 38.44 ( 33.05 )
12.4 29.49 ( 25.36 ) 32.69 ( 28.11 ) 34.52 ( 29.68 ) 38.63 ( 33.22 )
12.5 29.52 ( 25.39 ) 32.70 ( 28.12 ) 34.55 ( 29.71 ) 38.64 ( 33.23 )
12.6 29.56 ( 25.41 ) 32.71 ( 28.13 ) 34.58 ( 29.73 ) 38.65 ( 33.24 )
12.7 29.59 ( 25.44 ) 32.73 ( 28.14 ) 34.61 ( 29.76 ) 38.66 ( 33.25 )
12.8 29.62 ( 25.47 ) 32.74 ( 28.15 ) 34.64 ( 29.79 ) 38.68 ( 33.26 )
12.9 29.65 ( 25.49 ) 32.75 ( 28.16 ) 34.67 ( 29.81 ) 38.69 ( 33.27 )
13.0 29.68 ( 25.52 ) 32.76 ( 28.17 ) 34.70 ( 29.84 ) 38.70 ( 33.28 )
_
13.1 34.73 ( 29.87 ) 38.71 ( 33.29 )
13.2 34.77 ( 29.89 ) 38.72 ( 33.30 )
13.3 34.80 ( 29.92 ) 38.73 ( 33.31 )
13.4 34.83 ( 29.95 ) 38.75 ( 33.32 )
13.5 34.86 ( 29.97 ) 38.76 ( 33.32 )
13.6 34.89 ( 30.00 ) 38.77 ( 33.33 )
13.7 34.92 ( 30.03 ) 38.78 ( 33.34 )
13.8 34.95 ( 30.05 ) 38.79 ( 33.35 )
13.9 34.98 ( 30.08 ) 38.80 ( 33.36 )
14.0 35.01 ( 30.11 ) 38.81 ( 33.37 )
14.1 35.04 ( 30.13 ) 38.83 ( 33.38 )
14.2 35.08 ( 30.16 ) 38.84 ( 33.39 )
14.3 35.11 ( 30.19 ) 38.85 ( 33.40 )
_
14.4 35.14 ( 30.21 ) 38.86 ( 33.41 )
14.5 35.17 ( 30.24 ) 38.87 ( 33.42 )
14.6 35.20 ( 30.27 ) 38.88 ( 33.43 )
14.7 35.23 ( 30.29 ) 38.90 ( 33.44 )
14.8 35.26 ( 30.32 ) 38.91 ( 33.45 )
14.9 35.29 ( 30.35 ) 38.92 ( 33.46 )
15.0 35.32 ( 30.37 ) 38.93 ( 33.47 )
15.1 35.35 ( 30.40 ) 38.94 ( 33.48 )
15.2 35.39 ( 30.43 ) 38.95 ( 33.49 )
15.3 35.42 ( 30.45 ) 38.97 ( 33.50 )
15.4 35.45 ( 30.48 ) 38.98 ( 33.51 )
15.5 35.48 ( 30.51 ) 38.99 ( 33.52 )
15.6 35.51 ( 30.53 ) 39.00 ( 33.53 )

1-70 FAN-2209 201709


SELECTION DATA

Table 3. Outdoor Unit Capacity (JTOR140~180VPE(U,F,R)BS1) with Total Horsepower of Combined Indoor Unit (1)
Total Outdoor Unit Capacity: kW (×1000kcal/h)
RAS-14FSXNS
JTOR140VPE(U,F,R)BS1 RAS-16FSXNS
JTOR160VPE(U,F,R)BS1 RAS-18FSXNS
JTOR180VPE(U,F,R)BS1
Cooling Heating Cooling Heating Cooling Heating
7.0 20.00 ( 17.20 ) 22.50 ( 19.35 )
7.1 20.29 ( 17.44 ) 22.82 ( 19.62 )
7.2 20.57 ( 17.69 ) 23.14 ( 19.90 )
7.3 20.86 ( 17.93 ) 23.46 ( 20.18 )
7.4 21.14 ( 18.18 ) 23.79 ( 20.45 )
_
7.5 21.43 ( 18.43 ) 24.11 ( 20.73 )
7.6 21.71 ( 18.67 ) 24.43 ( 21.00 )
7.7 22.00 ( 18.92 ) 24.75 ( 21.28 )
7.8 22.29 ( 19.16 ) 25.07 ( 21.56 )
7.9 22.57 ( 19.41 ) 25.39 ( 21.83 )
_
8.0 22.86 ( 19.65 ) 25.71 ( 22.11 ) 22.50 ( 19.35 ) 25.00 ( 21.50 )
8.1 23.14 ( 19.90 ) 26.04 ( 22.39 ) 22.78 ( 19.59 ) 25.31 ( 21.76 )
8.2 23.43 ( 20.14 ) 26.36 ( 22.66 ) 23.06 ( 19.83 ) 25.62 ( 22.03 )
8.3 23.71 ( 20.39 ) 26.68 ( 22.94 ) 23.34 ( 20.07 ) 25.94 ( 22.30 )
8.4 24.00 ( 20.64 ) 27.00 ( 23.22 ) 23.62 ( 20.31 ) 26.25 ( 22.57 )
8.5 24.29 ( 20.88 ) 27.32 ( 23.49 ) 23.91 ( 20.56 ) 26.56 ( 22.84 )
8.6 24.57 ( 21.13 ) 27.64 ( 23.77 ) 24.19 ( 20.80 ) 26.87 ( 23.11 )
8.7 24.86 ( 21.37 ) 27.96 ( 24.04 ) 24.47 ( 21.04 ) 27.19 ( 23.38 )
8.8 25.14 ( 21.62 ) 28.29 ( 24.32 ) 24.75 ( 21.28 ) 27.50 ( 23.65 )
8.9 25.43 ( 21.86 ) 28.61 ( 24.60 ) 25.03 ( 21.52 ) 27.81 ( 23.91 )
9.0 25.71 ( 22.11 ) 28.93 ( 24.87 ) 25.31 ( 21.76 ) 28.12 ( 24.18 ) 25.00 ( 21.50 ) 28.00 ( 24.08 )
9.1 26.00 ( 22.36 ) 29.25 ( 25.15 ) 25.59 ( 22.01 ) 28.44 ( 24.45 ) 25.28 ( 21.73 ) 28.31 ( 24.34 )
9.2 26.29 ( 22.60 ) 29.57 ( 25.43 ) 25.87 ( 22.25 ) 28.75 ( 24.72 ) 25.56 ( 21.97 ) 28.62 ( 24.61 )
9.3 26.57 ( 22.85 ) 29.89 ( 25.70 ) 26.16 ( 22.49 ) 29.06 ( 24.99 ) 25.83 ( 22.21 ) 28.93 ( 24.88 )
9.4 26.86 ( 23.09 ) 30.21 ( 25.98 ) 26.44 ( 22.73 ) 29.37 ( 25.26 ) 26.11 ( 22.45 ) 29.24 ( 25.15 )
9.5 27.14 ( 23.34 ) 30.54 ( 26.26 ) 26.72 ( 22.97 ) 29.69 ( 25.53 ) 26.39 ( 22.69 ) 29.56 ( 25.41 )
9.6 27.43 ( 23.58 ) 30.86 ( 26.53 ) 27.00 ( 23.22 ) 30.00 ( 25.80 ) 26.67 ( 22.93 ) 29.87 ( 25.68 )
9.7 27.71 ( 23.83 ) 31.18 ( 26.81 ) 27.28 ( 23.46 ) 30.31 ( 26.06 ) 26.94 ( 23.17 ) 30.18 ( 25.95 )
9.8 28.00 ( 24.08 ) 31.50 ( 27.09 ) 27.56 ( 23.70 ) 30.62 ( 26.33 ) 27.22 ( 23.41 ) 30.49 ( 26.22 )
9.9 28.29 ( 24.32 ) 31.82 ( 27.36 ) 27.84 ( 23.94 ) 30.94 ( 26.60 ) 27.50 ( 23.65 ) 30.80 ( 26.48 )
10.0 28.57 ( 24.57 ) 32.14 ( 27.64 ) 28.12 ( 24.18 ) 31.25 ( 26.87 ) 27.78 ( 23.88 ) 31.11 ( 26.75 )
10.1 28.86 ( 24.81 ) 32.46 ( 27.91 ) 28.41 ( 24.42 ) 31.56 ( 27.14 ) 28.06 ( 24.12 ) 31.42 ( 27.02 )
10.2 29.14 ( 25.06 ) 32.79 ( 28.19 ) 28.69 ( 24.67 ) 31.87 ( 27.41 ) 28.33 ( 24.36 ) 31.73 ( 27.29 )
10.3 29.43 ( 25.30 ) 33.11 ( 28.47 ) 28.97 ( 24.91 ) 32.19 ( 27.68 ) 28.61 ( 24.60 ) 32.04 ( 27.55 )
10.4 29.71 ( 25.55 ) 33.43 ( 28.74 ) 29.25 ( 25.15 ) 32.50 ( 27.94 ) 28.89 ( 24.84 ) 32.36 ( 27.82 )
10.5 30.00 ( 25.80 ) 33.75 ( 29.02 ) 29.53 ( 25.39 ) 32.81 ( 28.21 ) 29.17 ( 25.08 ) 32.67 ( 28.09 )
10.6 30.29 ( 26.04 ) 34.07 ( 29.30 ) 29.81 ( 25.63 ) 33.12 ( 28.48 ) 29.44 ( 25.32 ) 32.98 ( 28.36 )
10.7 30.57 ( 26.29 ) 34.39 ( 29.57 ) 30.09 ( 25.88 ) 33.44 ( 28.75 ) 29.72 ( 25.56 ) 33.29 ( 28.62 )
10.8 30.86 ( 26.53 ) 34.71 ( 29.85 ) 30.37 ( 26.12 ) 33.75 ( 29.02 ) 30.00 ( 25.80 ) 33.60 ( 28.89 )
10.9 31.14 ( 26.78 ) 35.04 ( 30.13 ) 30.66 ( 26.36 ) 34.06 ( 29.29 ) 30.28 ( 26.03 ) 33.91 ( 29.16 )
11.0 31.43 ( 27.02 ) 35.36 ( 30.40 ) 30.94 ( 26.60 ) 34.37 ( 29.56 ) 30.56 ( 26.27 ) 34.22 ( 29.43 )
11.1 31.71 ( 27.27 ) 35.68 ( 30.68 ) 31.22 ( 26.84 ) 34.69 ( 29.83 ) 30.83 ( 26.51 ) 34.53 ( 29.69 )
11.2 32.00 ( 27.52 ) 36.00 ( 30.95 ) 31.50 ( 27.09 ) 35.00 ( 30.09 ) 31.11 ( 26.75 ) 34.84 ( 29.96 )
11.3 32.29 ( 27.76 ) 36.32 ( 31.23 ) 31.78 ( 27.33 ) 35.31 ( 30.36 ) 31.39 ( 26.99 ) 35.16 ( 30.23 )
11.4 32.57 ( 28.01 ) 36.64 ( 31.51 ) 32.06 ( 27.57 ) 35.62 ( 30.63 ) 31.67 ( 27.23 ) 35.47 ( 30.50 )
11.5 32.86 ( 28.25 ) 36.96 ( 31.78 ) 32.34 ( 27.81 ) 35.94 ( 30.90 ) 31.94 ( 27.47 ) 35.78 ( 30.76 )
11.6 33.14 ( 28.50 ) 37.29 ( 32.06 ) 32.62 ( 28.05 ) 36.25 ( 31.17 ) 32.22 ( 27.71 ) 36.09 ( 31.03 )
11.7 33.43 ( 28.74 ) 37.61 ( 32.34 ) 32.91 ( 28.29 ) 36.56 ( 31.44 ) 32.50 ( 27.94 ) 36.40 ( 31.30 )
11.8 33.71 ( 28.99 ) 37.93 ( 32.61 ) 33.19 ( 28.54 ) 36.87 ( 31.71 ) 32.78 ( 28.18 ) 36.71 ( 31.57 )
11.9 34.00 ( 29.23 ) 38.25 ( 32.89 ) 33.47 ( 28.78 ) 37.19 ( 31.98 ) 33.06 ( 28.42 ) 37.02 ( 31.83 )
12.0 34.29 ( 29.48 ) 38.57 ( 33.17 ) 33.75 ( 29.02 ) 37.50 ( 32.24 ) 33.33 ( 28.66 ) 37.33 ( 32.10 )
12.1 34.57 ( 29.73 ) 38.89 ( 33.44 ) 34.03 ( 29.26 ) 37.81 ( 32.51 ) 33.61 ( 28.90 ) 37.64 ( 32.37 )
12.2 34.86 ( 29.97 ) 39.21 ( 33.72 ) 34.31 ( 29.50 ) 38.12 ( 32.78 ) 33.89 ( 29.14 ) 37.96 ( 32.64 )
12.3 35.14 ( 30.22 ) 39.54 ( 33.99 ) 34.59 ( 29.75 ) 38.44 ( 33.05 ) 34.17 ( 29.38 ) 38.27 ( 32.90 )
12.4 35.43 ( 30.46 ) 39.86 ( 34.27 ) 34.87 ( 29.99 ) 38.75 ( 33.32 ) 34.44 ( 29.62 ) 38.58 ( 33.17 )
12.5 35.71 ( 30.71 ) 40.18 ( 34.55 ) 35.16 ( 30.23 ) 39.06 ( 33.59 ) 34.72 ( 29.86 ) 38.89 ( 33.44 )
12.6 36.00 ( 30.95 ) 40.50 ( 34.82 ) 35.44 ( 30.47 ) 39.37 ( 33.86 ) 35.00 ( 30.09 ) 39.20 ( 33.71 )
12.7 36.29 ( 31.20 ) 40.82 ( 35.10 ) 35.72 ( 30.71 ) 39.69 ( 34.13 ) 35.28 ( 30.33 ) 39.51 ( 33.97 )
12.8 36.57 ( 31.45 ) 41.14 ( 35.38 ) 36.00 ( 30.95 ) 40.00 ( 34.39 ) 35.56 ( 30.57 ) 39.82 ( 34.24 )
12.9 36.86 ( 31.69 ) 41.46 ( 35.65 ) 36.28 ( 31.20 ) 40.31 ( 34.66 ) 35.83 ( 30.81 ) 40.13 ( 34.51 )

FAN-2209 201709 1-71


SELECTION DATA

Table 4. Outdoor Unit Capacity (JTOR140~180VPE(U,F,R)BS1) with Total Horsepower of Combined Indoor Unit (2)
Total Outdoor Unit Capacity: kW (×1000kcal/h)
RAS-14FSXNS
JTOR140VPE(U,F,R)BS1 RAS-16FSXNS
JTOR160VPE(U,F,R)BS1 RAS-18FSXNS
JTOR180VPE(U,F,R)BS1
Cooling Heating Cooling Heating Cooling Heating
13.0 37.14 ( 31.94 ) 41.79 ( 35.93 ) 36.56 ( 31.44 ) 40.62 ( 34.93 ) 36.11 ( 31.05 ) 40.44 ( 34.78 )
13.1 37.43 ( 32.18 ) 42.11 ( 36.21 ) 36.84 ( 31.68 ) 40.94 ( 35.20 ) 36.39 ( 31.29 ) 40.76 ( 35.04 )
13.2 37.71 ( 32.43 ) 42.43 ( 36.48 ) 37.12 ( 31.92 ) 41.25 ( 35.47 ) 36.67 ( 31.53 ) 41.07 ( 35.31 )
13.3 38.00 ( 32.67 ) 42.75 ( 36.76 ) 37.41 ( 32.16 ) 41.56 ( 35.74 ) 36.94 ( 31.77 ) 41.38 ( 35.58 )
13.4 38.29 ( 32.92 ) 43.07 ( 37.03 ) 37.69 ( 32.41 ) 41.87 ( 36.01 ) 37.22 ( 32.01 ) 41.69 ( 35.85 )
13.5 38.57 ( 33.17 ) 43.39 ( 37.31 ) 37.97 ( 32.65 ) 42.19 ( 36.27 ) 37.50 ( 32.24 ) 42.00 ( 36.11 )
13.6 38.86 ( 33.41 ) 43.71 ( 37.59 ) 38.25 ( 32.89 ) 42.50 ( 36.54 ) 37.78 ( 32.48 ) 42.31 ( 36.38 )
13.7 39.14 ( 33.66 ) 44.04 ( 37.86 ) 38.53 ( 33.13 ) 42.81 ( 36.81 ) 38.06 ( 32.72 ) 42.62 ( 36.65 )
13.8 39.43 ( 33.90 ) 44.36 ( 38.14 ) 38.81 ( 33.37 ) 43.12 ( 37.08 ) 38.33 ( 32.96 ) 42.93 ( 36.92 )
13.9 39.71 ( 34.15 ) 44.68 ( 38.42 ) 39.09 ( 33.61 ) 43.44 ( 37.35 ) 38.61 ( 33.20 ) 43.24 ( 37.18 )
14.0 40.00 ( 34.39 ) 45.00 ( 38.69 ) 39.37 ( 33.86 ) 43.75 ( 37.62 ) 38.89 ( 33.44 ) 43.56 ( 37.45 )
14.1 40.29 ( 34.64 ) 45.32 ( 38.97 ) 39.66 ( 34.10 ) 44.06 ( 37.89 ) 39.17 ( 33.68 ) 43.87 ( 37.72 )
14.2 40.57 ( 34.89 ) 45.64 ( 39.25 ) 39.94 ( 34.34 ) 44.38 ( 38.16 ) 39.44 ( 33.92 ) 44.18 ( 37.99 )
14.3 40.86 ( 35.13 ) 45.96 ( 39.52 ) 40.22 ( 34.58 ) 44.69 ( 38.42 ) 39.72 ( 34.15 ) 44.49 ( 38.25 )
14.4 41.14 ( 35.38 ) 46.29 ( 39.80 ) 40.50 ( 34.82 ) 45.00 ( 38.69 ) 40.00 ( 34.39 ) 44.80 ( 38.52 )
14.5 41.23 ( 35.45 ) 46.36 ( 39.86 ) 40.78 ( 35.07 ) 45.31 ( 38.96 ) 40.28 ( 34.63 ) 45.11 ( 38.79 )
14.6 41.26 ( 35.47 ) 46.37 ( 39.87 ) 41.06 ( 35.31 ) 45.63 ( 39.23 ) 40.56 ( 34.87 ) 45.42 ( 39.06 )
14.7 41.29 ( 35.50 ) 46.38 ( 39.88 ) 41.34 ( 35.55 ) 45.94 ( 39.50 ) 40.83 ( 35.11 ) 45.73 ( 39.32 )
14.8 41.32 ( 35.53 ) 46.40 ( 39.89 ) 41.63 ( 35.79 ) 46.25 ( 39.77 ) 41.11 ( 35.35 ) 46.04 ( 39.59 )
14.9 41.35 ( 35.56 ) 46.41 ( 39.90 ) 41.91 ( 36.03 ) 46.56 ( 40.04 ) 41.39 ( 35.59 ) 46.36 ( 39.86 )
15.0 41.38 ( 35.58 ) 46.42 ( 39.91 ) 42.19 ( 36.27 ) 46.88 ( 40.31 ) 41.67 ( 35.83 ) 46.67 ( 40.13 )
15.1 41.42 ( 35.61 ) 46.43 ( 39.92 ) 42.47 ( 36.52 ) 47.19 ( 40.57 ) 41.94 ( 36.07 ) 46.98 ( 40.39 )
15.2 41.45 ( 35.64 ) 46.44 ( 39.93 ) 42.75 ( 36.76 ) 47.50 ( 40.84 ) 42.22 ( 36.30 ) 47.29 ( 40.66 )
15.3 41.48 ( 35.67 ) 46.45 ( 39.94 ) 43.03 ( 37.00 ) 47.81 ( 41.11 ) 42.50 ( 36.54 ) 47.60 ( 40.93 )
15.4 41.51 ( 35.69 ) 46.47 ( 39.95 ) 43.31 ( 37.24 ) 48.13 ( 41.38 ) 42.78 ( 36.78 ) 47.91 ( 41.20 )
15.5 41.54 ( 35.72 ) 46.48 ( 39.96 ) 43.59 ( 37.48 ) 48.44 ( 41.65 ) 43.06 ( 37.02 ) 48.22 ( 41.46 )
15.6 41.57 ( 35.75 ) 46.49 ( 39.97 ) 43.88 ( 37.73 ) 48.75 ( 41.92 ) 43.33 ( 37.26 ) 48.53 ( 41.73 )
15.7 41.61 ( 35.78 ) 46.50 ( 39.98 ) 44.16 ( 37.97 ) 49.06 ( 42.19 ) 43.61 ( 37.50 ) 48.84 ( 42.00 )
15.8 41.64 ( 35.80 ) 46.51 ( 40.00 ) 44.44 ( 38.21 ) 49.38 ( 42.45 ) 43.89 ( 37.74 ) 49.16 ( 42.27 )
15.9 41.67 ( 35.83 ) 46.53 ( 40.01 ) 44.72 ( 38.45 ) 49.69 ( 42.72 ) 44.17 ( 37.98 ) 49.47 ( 42.53 )
16.0 41.70 ( 35.86 ) 46.54 ( 40.02 ) 45.00 ( 38.69 ) 50.00 ( 42.99 ) 44.44 ( 38.22 ) 49.78 ( 42.80 )
16.1 41.73 ( 35.88 ) 46.55 ( 40.03 ) 45.03 ( 38.72 ) 50.02 ( 43.01 ) 44.72 ( 38.45 ) 50.09 ( 43.07 )
16.2 41.77 ( 35.91 ) 46.56 ( 40.04 ) 45.06 ( 38.74 ) 50.04 ( 43.03 ) 45.00 ( 38.69 ) 50.40 ( 43.34 )
16.3 41.80 ( 35.94 ) 46.57 ( 40.05 ) 45.08 ( 38.77 ) 50.06 ( 43.05 ) 45.28 ( 38.93 ) 50.71 ( 43.60 )
16.4 41.83 ( 35.97 ) 46.59 ( 40.06 ) 45.11 ( 38.79 ) 50.08 ( 43.06 ) 45.56 ( 39.17 ) 51.02 ( 43.87 )
16.5 41.86 ( 35.99 ) 46.60 ( 40.07 ) 45.14 ( 38.81 ) 50.10 ( 43.08 ) 45.83 ( 39.41 ) 51.33 ( 44.14 )
16.6 41.89 ( 36.02 ) 46.61 ( 40.08 ) 45.17 ( 38.84 ) 50.13 ( 43.10 ) 46.11 ( 39.65 ) 51.64 ( 44.41 )
16.7 41.92 ( 36.05 ) 46.62 ( 40.09 ) 45.20 ( 38.86 ) 50.15 ( 43.12 ) 46.39 ( 39.89 ) 51.96 ( 44.67 )
16.8 41.96 ( 36.08 ) 46.63 ( 40.10 ) 45.23 ( 38.89 ) 50.17 ( 43.14 ) 46.67 ( 40.13 ) 52.27 ( 44.94 )
16.9 41.99 ( 36.10 ) 46.65 ( 40.11 ) 45.25 ( 38.91 ) 50.19 ( 43.15 ) 46.94 ( 40.36 ) 52.58 ( 45.21 )
17.0 42.02 ( 36.13 ) 46.66 ( 40.12 ) 45.28 ( 38.93 ) 50.21 ( 43.17 ) 47.22 ( 40.60 ) 52.89 ( 45.48 )
17.1 42.05 ( 36.16 ) 46.67 ( 40.13 ) 45.31 ( 38.96 ) 50.23 ( 43.19 ) 47.50 ( 40.84 ) 53.20 ( 45.74 )
17.2 42.08 ( 36.18 ) 46.68 ( 40.14 ) 45.34 ( 38.98 ) 50.25 ( 43.21 ) 47.78 ( 41.08 ) 53.51 ( 46.01 )
17.3 42.11 ( 36.21 ) 46.69 ( 40.15 ) 45.37 ( 39.01 ) 50.27 ( 43.23 ) 48.06 ( 41.32 ) 53.82 ( 46.28 )
17.4 42.15 ( 36.24 ) 46.70 ( 40.16 ) 45.39 ( 39.03 ) 50.29 ( 43.24 ) 48.33 ( 41.56 ) 54.13 ( 46.55 )
17.5 42.18 ( 36.27 ) 46.72 ( 40.17 ) 45.42 ( 39.06 ) 50.31 ( 43.26 ) 48.61 ( 41.80 ) 54.44 ( 46.81 )
17.6 42.21 ( 36.29 ) 46.73 ( 40.18 ) 45.45 ( 39.08 ) 50.33 ( 43.28 ) 48.89 ( 42.04 ) 54.76 ( 47.08 )
17.7 42.24 ( 36.32 ) 46.74 ( 40.19 ) 45.48 ( 39.10 ) 50.35 ( 43.30 ) 49.17 ( 42.28 ) 55.07 ( 47.35 )
17.8 42.27 ( 36.35 ) 46.75 ( 40.20 ) 45.51 ( 39.13 ) 50.38 ( 43.31 ) 49.44 ( 42.51 ) 55.38 ( 47.62 )
17.9 42.30 ( 36.38 ) 46.76 ( 40.21 ) 45.53 ( 39.15 ) 50.40 ( 43.33 ) 49.72 ( 42.75 ) 55.69 ( 47.88 )
18.0 42.34 ( 36.40 ) 46.78 ( 40.22 ) 45.56 ( 39.18 ) 50.42 ( 43.35 ) 50.00 ( 42.99 ) 56.00 ( 48.15 )
18.1 42.37 ( 36.43 ) 46.79 ( 40.23 ) 45.59 ( 39.20 ) 50.44 ( 43.37 ) 50.28 ( 43.23 ) 56.31 ( 48.42 )
18.2 42.40 ( 36.46 ) 46.80 ( 40.24 ) 45.62 ( 39.23 ) 50.46 ( 43.39 ) 50.56 ( 43.47 ) 56.62 ( 48.69 )
18.3 45.65 ( 39.25 ) 50.48 ( 43.40 ) 50.83 ( 43.71 ) 56.93 ( 48.95 )
18.4 45.68 ( 39.27 ) 50.50 ( 43.42 ) 51.11 ( 43.95 ) 57.24 ( 49.22 )
18.5 45.70 ( 39.30 ) 50.52 ( 43.44 ) 51.39 ( 44.19 ) 57.56 ( 49.49 )
18.6 _ 45.73 ( 39.32 ) 50.54 ( 43.46 ) 51.52 ( 44.30 ) 57.69 ( 49.60 )
18.7 45.76 ( 39.35 ) 50.56 ( 43.48 ) 51.55 ( 44.32 ) 57.70 ( 49.61 )
18.8 45.79 ( 39.37 ) 50.58 ( 43.49 ) 51.58 ( 44.35 ) 57.71 ( 49.62 )
18.9 45.82 ( 39.39 ) 50.60 ( 43.51 ) 51.61 ( 44.38 ) 57.72 ( 49.63 )

1-72 FAN-2209 201709


SELECTION DATA

Table 5. Outdoor Unit Capacity (JTOR140~180VPE(U,F,R)BS1) with Total Horsepower of Combined Indoor Unit (3)
Total Outdoor Unit Capacity: kW (×1000kcal/h)
RAS-14FSXNS
JTOR140VPE(U,F,R)BS1 RAS-16FSXNS
JTOR160VPE(U,F,R)BS1 RAS-18FSXNS
JTOR180VPE(U,F,R)BS1
Cooling Heating Cooling Heating Cooling Heating
19.0 45.65 ( 39.25 ) 50.48 ( 43.40 ) 51.64 ( 44.40 ) 57.73 ( 49.64 )
19.1 45.68 ( 39.27 ) 50.50 ( 43.42 ) 51.67 ( 44.43 ) 57.74 ( 49.65 )
19.2 45.70 ( 39.30 ) 50.52 ( 43.44 ) 51.70 ( 44.46 ) 57.76 ( 49.66 )
19.3 45.73 ( 39.32 ) 50.54 ( 43.46 ) 51.73 ( 44.48 ) 57.77 ( 49.67 )
19.4 45.76 ( 39.35 ) 50.56 ( 43.48 ) 51.77 ( 44.51 ) 57.78 ( 49.68 )
19.5 45.79 ( 39.37 ) 50.58 ( 43.49 ) 51.80 ( 44.54 ) 57.79 ( 49.69 )
19.6 45.82 ( 39.39 ) 50.60 ( 43.51 ) 51.83 ( 44.56 ) 57.80 ( 49.70 )
19.7 45.84 ( 39.42 ) 50.63 ( 43.53 ) 51.86 ( 44.59 ) 57.81 ( 49.71 )
19.8 45.87 ( 39.44 ) 50.65 ( 43.55 ) 51.89 ( 44.62 ) 57.83 ( 49.72 )
19.9 45.90 ( 39.47 ) 50.67 ( 43.57 ) 51.92 ( 44.64 ) 57.84 ( 49.73 )
20.0 45.93 ( 39.49 ) 50.69 ( 43.58 ) 51.95 ( 44.67 ) 57.85 ( 49.74 )
20.1 45.96 ( 39.52 ) 50.71 ( 43.60 ) 51.98 ( 44.70 ) 57.86 ( 49.75 )
20.2 45.98 ( 39.54 ) 50.73 ( 43.62 ) 52.01 ( 44.72 ) 57.87 ( 49.76 )
20.3 46.01 ( 39.56 ) 50.75 ( 43.64 ) 52.04 ( 44.75 ) 57.88 ( 49.77 )
20.4 46.04 ( 39.59 ) 50.77 ( 43.66 ) 52.07 ( 44.78 ) 57.89 ( 49.78 )
20.5 46.07 ( 39.61 ) 50.79 ( 43.67 ) 52.10 ( 44.80 ) 57.91 ( 49.79 )
20.6 46.10 ( 39.64 ) 50.81 ( 43.69 ) 52.14 ( 44.83 ) 57.92 ( 49.80 )
20.7 46.13 ( 39.66 ) 50.83 ( 43.71 ) 52.17 ( 44.86 ) 57.93 ( 49.81 )
20.8 46.15 ( 39.68 ) 50.85 ( 43.73 ) 52.20 ( 44.88 ) 57.94 ( 49.82 )
20.9 46.18 ( 39.71 ) 50.88 ( 43.74 ) 52.23 ( 44.91 ) 57.95 ( 49.83 )
21.0 46.21 ( 39.73 ) 50.90 ( 43.76 ) 52.26 ( 44.93 ) 57.96 ( 49.84 )
21.1 46.24 ( 39.76 ) 50.92 ( 43.78 ) 52.29 ( 44.96 ) 57.97 ( 49.85 )
21.2 _ 46.27 ( 39.78 ) 50.94 ( 43.80 ) 52.32 ( 44.99 ) 57.99 ( 49.86 )
21.3 46.29 ( 39.81 ) 50.96 ( 43.82 ) 52.35 ( 45.01 ) 58.00 ( 49.87 )
21.4 46.32 ( 39.83 ) 50.98 ( 43.83 ) 52.38 ( 45.04 ) 58.01 ( 49.88 )
21.5 46.35 ( 39.85 ) 51.00 ( 43.85 ) 52.41 ( 45.07 ) 58.02 ( 49.89 )
21.6 52.44 ( 45.09 ) 58.03 ( 49.90 )
21.7 52.48 ( 45.12 ) 58.04 ( 49.91 )
21.8 52.51 ( 45.15 ) 58.06 ( 49.92 )
21.9 52.54 ( 45.17 ) 58.07 ( 49.93 )
22.0 52.57 ( 45.20 ) 58.08 ( 49.94 )
22.1 52.60 ( 45.23 ) 58.09 ( 49.95 )
22.2 52.63 ( 45.25 ) 58.10 ( 49.96 )
22.3 52.66 ( 45.28 ) 58.11 ( 49.97 )
22.4 52.69 ( 45.31 ) 58.12 ( 49.98 )
22.5 _ 52.72 ( 45.33 ) 58.14 ( 49.99 )
22.6 52.75 ( 45.36 ) 58.15 ( 50.00 )
22.7 52.78 ( 45.39 ) 58.16 ( 50.01 )
22.8 52.81 ( 45.41 ) 58.17 ( 50.02 )
22.9 52.85 ( 45.44 ) 58.18 ( 50.03 )
23.0 52.88 ( 45.47 ) 58.19 ( 50.04 )
23.1 52.91 ( 45.49 ) 58.21 ( 50.05 )
23.2 52.94 ( 45.52 ) 58.22 ( 50.06 )
23.3 52.97 ( 45.55 ) 58.23 ( 50.07 )
23.4 53.00 ( 45.57 ) 58.24 ( 50.08 )

FAN-2209 201709 1-73


SELECTION DATA

Table 6. Outdoor Unit Capacity (JTOR200~240VPE(U,F,R)BS1) with Total Horsepower of Combined Indoor Unit (1)
Total Outdoor Unit Capacity: kW (×1000kcal/h)
RAS-20FSXNS
JTOR200VPE(U,F,R)BS1 RAS-22FSXNS
JTOR220VPE(U,F,R)BS1 RAS-24FSXNS
JTOR240VPE(U,F,R)BS1
Cooling Heating Cooling Heating Cooling Heating
10.0 28.00 ( 24.08 ) 31.50 ( 27.09 )
10.1 28.28 ( 24.32 ) 31.81 ( 27.36 )
10.2 28.56 ( 24.56 ) 32.13 ( 27.63 )
10.3 28.84 ( 24.80 ) 32.44 ( 27.90 )
10.4 29.12 ( 25.04 ) 32.76 ( 28.17 )
_
10.5 29.40 ( 25.28 ) 33.07 ( 28.44 )
10.6 29.68 ( 25.52 ) 33.39 ( 28.71 )
10.7 29.96 ( 25.76 ) 33.70 ( 28.98 )
10.8 30.24 ( 26.00 ) 34.02 ( 29.25 )
10.9 30.52 ( 26.24 ) 34.33 ( 29.52 )
_
11.0 30.80 ( 26.48 ) 34.65 ( 29.79 ) 30.75 ( 26.44 ) 34.50 ( 29.66 )
11.1 31.08 ( 26.72 ) 34.96 ( 30.06 ) 31.03 ( 26.68 ) 34.81 ( 29.93 )
11.2 31.36 ( 26.96 ) 35.28 ( 30.34 ) 31.31 ( 26.92 ) 35.13 ( 30.20 )
11.3 31.64 ( 27.21 ) 35.59 ( 30.61 ) 31.59 ( 27.16 ) 35.44 ( 30.47 )
11.4 31.92 ( 27.45 ) 35.91 ( 30.88 ) 31.87 ( 27.40 ) 35.75 ( 30.74 )
11.5 32.20 ( 27.69 ) 36.22 ( 31.15 ) 32.15 ( 27.64 ) 36.07 ( 31.01 )
11.6 32.48 ( 27.93 ) 36.54 ( 31.42 ) 32.43 ( 27.88 ) 36.38 ( 31.28 )
11.7 32.76 ( 28.17 ) 36.85 ( 31.69 ) 32.71 ( 28.12 ) 36.70 ( 31.55 )
11.8 33.04 ( 28.41 ) 37.17 ( 31.96 ) 32.99 ( 28.36 ) 37.01 ( 31.82 )
11.9 33.32 ( 28.65 ) 37.48 ( 32.23 ) 33.27 ( 28.60 ) 37.32 ( 32.09 )
12.0 33.60 ( 28.89 ) 37.80 ( 32.50 ) 33.55 ( 28.84 ) 37.64 ( 32.36 ) 33.50 ( 28.80 ) 38.75 ( 33.32 )
12.1 33.88 ( 29.13 ) 38.11 ( 32.77 ) 33.82 ( 29.08 ) 37.95 ( 32.63 ) 33.78 ( 29.04 ) 39.07 ( 33.60 )
12.2 34.16 ( 29.37 ) 38.43 ( 33.04 ) 34.10 ( 29.32 ) 38.26 ( 32.90 ) 34.06 ( 29.28 ) 39.40 ( 33.87 )
12.3 34.44 ( 29.61 ) 38.74 ( 33.31 ) 34.38 ( 29.56 ) 38.58 ( 33.17 ) 34.34 ( 29.52 ) 39.72 ( 34.15 )
12.4 34.72 ( 29.85 ) 39.06 ( 33.59 ) 34.66 ( 29.81 ) 38.89 ( 33.44 ) 34.62 ( 29.76 ) 40.04 ( 34.43 )
12.5 35.00 ( 30.09 ) 39.37 ( 33.86 ) 34.94 ( 30.05 ) 39.20 ( 33.71 ) 34.90 ( 30.01 ) 40.36 ( 34.71 )
12.6 35.28 ( 30.34 ) 39.69 ( 34.13 ) 35.22 ( 30.29 ) 39.52 ( 33.98 ) 35.17 ( 30.25 ) 40.69 ( 34.98 )
12.7 35.56 ( 30.58 ) 40.00 ( 34.40 ) 35.50 ( 30.53 ) 39.83 ( 34.25 ) 35.45 ( 30.49 ) 41.01 ( 35.26 )
12.8 35.84 ( 30.82 ) 40.32 ( 34.67 ) 35.78 ( 30.77 ) 40.15 ( 34.52 ) 35.73 ( 30.73 ) 41.33 ( 35.54 )
12.9 36.12 ( 31.06 ) 40.63 ( 34.94 ) 36.06 ( 31.01 ) 40.46 ( 34.79 ) 36.01 ( 30.97 ) 41.66 ( 35.82 )
13.0 36.40 ( 31.30 ) 40.95 ( 35.21 ) 36.34 ( 31.25 ) 40.77 ( 35.06 ) 36.29 ( 31.21 ) 41.98 ( 36.10 )
13.1 36.68 ( 31.54 ) 41.26 ( 35.48 ) 36.62 ( 31.49 ) 41.09 ( 35.33 ) 36.57 ( 31.45 ) 42.30 ( 36.37 )
13.2 36.96 ( 31.78 ) 41.58 ( 35.75 ) 36.90 ( 31.73 ) 41.40 ( 35.60 ) 36.85 ( 31.69 ) 42.62 ( 36.65 )
13.3 37.24 ( 32.02 ) 41.89 ( 36.02 ) 37.18 ( 31.97 ) 41.71 ( 35.87 ) 37.13 ( 31.93 ) 42.95 ( 36.93 )
13.4 37.52 ( 32.26 ) 42.21 ( 36.29 ) 37.46 ( 32.21 ) 42.03 ( 36.14 ) 37.41 ( 32.17 ) 43.27 ( 37.21 )
13.5 37.80 ( 32.50 ) 42.52 ( 36.56 ) 37.74 ( 32.45 ) 42.34 ( 36.41 ) 37.69 ( 32.41 ) 43.59 ( 37.48 )
13.6 38.08 ( 32.74 ) 42.84 ( 36.84 ) 38.02 ( 32.69 ) 42.65 ( 36.68 ) 37.97 ( 32.65 ) 43.92 ( 37.76 )
13.7 38.36 ( 32.98 ) 43.15 ( 37.11 ) 38.30 ( 32.93 ) 42.97 ( 36.95 ) 38.25 ( 32.89 ) 44.24 ( 38.04 )
13.8 38.64 ( 33.22 ) 43.47 ( 37.38 ) 38.58 ( 33.17 ) 43.28 ( 37.22 ) 38.52 ( 33.13 ) 44.56 ( 38.32 )
13.9 38.92 ( 33.47 ) 43.78 ( 37.65 ) 38.86 ( 33.41 ) 43.60 ( 37.49 ) 38.80 ( 33.37 ) 44.89 ( 38.59 )
14.0 39.20 ( 33.71 ) 44.10 ( 37.92 ) 39.14 ( 33.65 ) 43.91 ( 37.76 ) 39.08 ( 33.61 ) 45.21 ( 38.87 )
14.1 39.48 ( 33.95 ) 44.42 ( 38.19 ) 39.42 ( 33.89 ) 44.22 ( 38.02 ) 39.36 ( 33.85 ) 45.53 ( 39.15 )
14.2 39.76 ( 34.19 ) 44.73 ( 38.46 ) 39.70 ( 34.13 ) 44.54 ( 38.29 ) 39.64 ( 34.09 ) 45.85 ( 39.43 )
14.3 40.04 ( 34.43 ) 45.05 ( 38.73 ) 39.97 ( 34.37 ) 44.85 ( 38.56 ) 39.92 ( 34.33 ) 46.18 ( 39.71 )
14.4 40.32 ( 34.67 ) 45.36 ( 39.00 ) 40.25 ( 34.61 ) 45.16 ( 38.83 ) 40.20 ( 34.57 ) 46.50 ( 39.98 )
14.5 40.60 ( 34.91 ) 45.68 ( 39.27 ) 40.53 ( 34.85 ) 45.48 ( 39.10 ) 40.48 ( 34.81 ) 46.82 ( 40.26 )
14.6 40.88 ( 35.15 ) 45.99 ( 39.54 ) 40.81 ( 35.09 ) 45.79 ( 39.37 ) 40.76 ( 35.05 ) 47.15 ( 40.54 )
14.7 41.16 ( 35.39 ) 46.31 ( 39.82 ) 41.09 ( 35.33 ) 46.10 ( 39.64 ) 41.04 ( 35.29 ) 47.47 ( 40.82 )
14.8 41.44 ( 35.63 ) 46.62 ( 40.09 ) 41.37 ( 35.57 ) 46.42 ( 39.91 ) 41.32 ( 35.53 ) 47.79 ( 41.09 )
14.9 41.72 ( 35.87 ) 46.94 ( 40.36 ) 41.65 ( 35.81 ) 46.73 ( 40.18 ) 41.60 ( 35.77 ) 48.11 ( 41.37 )
15.0 42.00 ( 36.11 ) 47.25 ( 40.63 ) 41.93 ( 36.05 ) 47.05 ( 40.45 ) 41.87 ( 36.01 ) 48.44 ( 41.65 )
15.1 42.28 ( 36.35 ) 47.57 ( 40.90 ) 42.21 ( 36.30 ) 47.36 ( 40.72 ) 42.15 ( 36.25 ) 48.76 ( 41.93 )
15.2 42.56 ( 36.60 ) 47.88 ( 41.17 ) 42.49 ( 36.54 ) 47.67 ( 40.99 ) 42.43 ( 36.49 ) 49.08 ( 42.20 )
15.3 42.84 ( 36.84 ) 48.20 ( 41.44 ) 42.77 ( 36.78 ) 47.99 ( 41.26 ) 42.71 ( 36.73 ) 49.41 ( 42.48 )
15.4 43.12 ( 37.08 ) 48.51 ( 41.71 ) 43.05 ( 37.02 ) 48.30 ( 41.53 ) 42.99 ( 36.97 ) 49.73 ( 42.76 )
15.5 43.40 ( 37.32 ) 48.83 ( 41.98 ) 43.33 ( 37.26 ) 48.61 ( 41.80 ) 43.27 ( 37.21 ) 50.05 ( 43.04 )
15.6 43.68 ( 37.56 ) 49.14 ( 42.25 ) 43.61 ( 37.50 ) 48.93 ( 42.07 ) 43.55 ( 37.45 ) 50.37 ( 43.31 )
15.7 43.96 ( 37.80 ) 49.46 ( 42.52 ) 43.89 ( 37.74 ) 49.24 ( 42.34 ) 43.83 ( 37.69 ) 50.70 ( 43.59 )
15.8 44.24 ( 38.04 ) 49.77 ( 42.79 ) 44.17 ( 37.98 ) 49.55 ( 42.61 ) 44.11 ( 37.93 ) 51.02 ( 43.87 )
15.9 44.52 ( 38.28 ) 50.09 ( 43.07 ) 44.45 ( 38.22 ) 49.87 ( 42.88 ) 44.39 ( 38.17 ) 51.34 ( 44.15 )

1-74 FAN-2209 201709


SELECTION DATA

Table 7. Outdoor Unit Capacity (JTOR200~240VPE(U,F,R)BS1) with Total Horsepower of Combined Indoor Unit (2)
Total Outdoor Unit Capacity: kW (×1000kcal/h)
RAS-20FSXNS
JTOR200VPE(U,F,R)BS1 RAS-22FSXNS
JTOR220VPE(U,F,R)BS1 RAS-24FSXNS
JTOR240VPE(U,F,R)BS1
Cooling Heating Cooling Heating Cooling Heating
16.0 44.80 ( 38.52 ) 50.40 ( 43.34 ) 44.73 ( 38.46 ) 50.18 ( 43.15 ) 44.67 ( 38.41 ) 51.67 ( 44.43 )
16.1 45.08 ( 38.76 ) 50.72 ( 43.61 ) 45.01 ( 38.70 ) 50.50 ( 43.42 ) 44.95 ( 38.65 ) 51.99 ( 44.70 )
16.2 45.36 ( 39.00 ) 51.03 ( 43.88 ) 45.29 ( 38.94 ) 50.81 ( 43.69 ) 45.22 ( 38.89 ) 52.31 ( 44.98 )
16.3 45.64 ( 39.24 ) 51.35 ( 44.15 ) 45.57 ( 39.18 ) 51.12 ( 43.96 ) 45.50 ( 39.13 ) 52.64 ( 45.26 )
16.4 45.92 ( 39.48 ) 51.66 ( 44.42 ) 45.85 ( 39.42 ) 51.44 ( 44.23 ) 45.78 ( 39.37 ) 52.96 ( 45.54 )
16.5 46.20 ( 39.72 ) 51.98 ( 44.69 ) 46.12 ( 39.66 ) 51.75 ( 44.50 ) 46.06 ( 39.61 ) 53.28 ( 45.81 )
16.6 46.48 ( 39.97 ) 52.29 ( 44.96 ) 46.40 ( 39.90 ) 52.06 ( 44.77 ) 46.34 ( 39.85 ) 53.60 ( 46.09 )
16.7 46.76 ( 40.21 ) 52.61 ( 45.23 ) 46.68 ( 40.14 ) 52.38 ( 45.04 ) 46.62 ( 40.09 ) 53.93 ( 46.37 )
16.8 47.04 ( 40.45 ) 52.92 ( 45.50 ) 46.96 ( 40.38 ) 52.69 ( 45.31 ) 46.90 ( 40.33 ) 54.25 ( 46.65 )
16.9 47.32 ( 40.69 ) 53.24 ( 45.77 ) 47.24 ( 40.62 ) 53.00 ( 45.58 ) 47.18 ( 40.57 ) 54.57 ( 46.92 )
17.0 47.60 ( 40.93 ) 53.55 ( 46.04 ) 47.52 ( 40.86 ) 53.32 ( 45.85 ) 47.46 ( 40.81 ) 54.90 ( 47.20 )
17.1 47.88 ( 41.17 ) 53.87 ( 46.32 ) 47.80 ( 41.10 ) 53.63 ( 46.12 ) 47.74 ( 41.05 ) 55.22 ( 47.48 )
17.2 48.16 ( 41.41 ) 54.18 ( 46.59 ) 48.08 ( 41.34 ) 53.95 ( 46.38 ) 48.02 ( 41.29 ) 55.54 ( 47.76 )
17.3 48.44 ( 41.65 ) 54.50 ( 46.86 ) 48.36 ( 41.58 ) 54.26 ( 46.65 ) 48.30 ( 41.53 ) 55.86 ( 48.03 )
17.4 48.72 ( 41.89 ) 54.81 ( 47.13 ) 48.64 ( 41.82 ) 54.57 ( 46.92 ) 48.57 ( 41.77 ) 56.19 ( 48.31 )
17.5 49.00 ( 42.13 ) 55.13 ( 47.40 ) 48.92 ( 42.06 ) 54.89 ( 47.19 ) 48.85 ( 42.01 ) 56.51 ( 48.59 )
17.6 49.28 ( 42.37 ) 55.44 ( 47.67 ) 49.20 ( 42.30 ) 55.20 ( 47.46 ) 49.13 ( 42.25 ) 56.83 ( 48.87 )
17.7 49.56 ( 42.61 ) 55.76 ( 47.94 ) 49.48 ( 42.54 ) 55.51 ( 47.73 ) 49.41 ( 42.49 ) 57.16 ( 49.15 )
17.8 49.84 ( 42.85 ) 56.07 ( 48.21 ) 49.76 ( 42.79 ) 55.83 ( 48.00 ) 49.69 ( 42.73 ) 57.48 ( 49.42 )
17.9 50.12 ( 43.10 ) 56.39 ( 48.48 ) 50.04 ( 43.03 ) 56.14 ( 48.27 ) 49.97 ( 42.97 ) 57.80 ( 49.70 )
18.0 50.40 ( 43.34 ) 56.70 ( 48.75 ) 50.32 ( 43.27 ) 56.45 ( 48.54 ) 50.25 ( 43.21 ) 58.12 ( 49.98 )
18.1 50.68 ( 43.58 ) 57.02 ( 49.02 ) 50.60 ( 43.51 ) 56.77 ( 48.81 ) 50.53 ( 43.45 ) 58.45 ( 50.26 )
18.2 50.96 ( 43.82 ) 57.33 ( 49.29 ) 50.88 ( 43.75 ) 57.08 ( 49.08 ) 50.81 ( 43.69 ) 58.77 ( 50.53 )
18.3 51.24 ( 44.06 ) 57.65 ( 49.57 ) 51.16 ( 43.99 ) 57.40 ( 49.35 ) 51.09 ( 43.93 ) 59.09 ( 50.81 )
18.4 51.52 ( 44.30 ) 57.96 ( 49.84 ) 51.44 ( 44.23 ) 57.71 ( 49.62 ) 51.37 ( 44.17 ) 59.42 ( 51.09 )
18.5 51.80 ( 44.54 ) 58.28 ( 50.11 ) 51.72 ( 44.47 ) 58.02 ( 49.89 ) 51.65 ( 44.41 ) 59.74 ( 51.37 )
18.6 52.08 ( 44.78 ) 58.59 ( 50.38 ) 52.00 ( 44.71 ) 58.34 ( 50.16 ) 51.92 ( 44.65 ) 60.06 ( 51.64 )
18.7 52.36 ( 45.02 ) 58.91 ( 50.65 ) 52.27 ( 44.95 ) 58.65 ( 50.43 ) 52.20 ( 44.89 ) 60.39 ( 51.92 )
18.8 52.64 ( 45.26 ) 59.22 ( 50.92 ) 52.55 ( 45.19 ) 58.96 ( 50.70 ) 52.48 ( 45.13 ) 60.71 ( 52.20 )
18.9 52.92 ( 45.50 ) 59.54 ( 51.19 ) 52.83 ( 45.43 ) 59.28 ( 50.97 ) 52.76 ( 45.37 ) 61.03 ( 52.48 )
19.0 53.20 ( 45.74 ) 59.85 ( 51.46 ) 53.11 ( 45.67 ) 59.59 ( 51.24 ) 53.04 ( 45.61 ) 61.35 ( 52.76 )
19.1 53.48 ( 45.98 ) 60.17 ( 51.73 ) 53.39 ( 45.91 ) 59.90 ( 51.51 ) 53.32 ( 45.85 ) 61.68 ( 53.03 )
19.2 53.76 ( 46.23 ) 60.48 ( 52.00 ) 53.67 ( 46.15 ) 60.22 ( 51.78 ) 53.60 ( 46.09 ) 62.00 ( 53.31 )
19.3 54.04 ( 46.47 ) 60.80 ( 52.27 ) 53.95 ( 46.39 ) 60.53 ( 52.05 ) 53.88 ( 46.33 ) 62.32 ( 53.59 )
19.4 54.32 ( 46.71 ) 61.11 ( 52.55 ) 54.23 ( 46.63 ) 60.85 ( 52.32 ) 54.16 ( 46.57 ) 62.65 ( 53.87 )
19.5 54.60 ( 46.95 ) 61.43 ( 52.82 ) 54.51 ( 46.87 ) 61.16 ( 52.59 ) 54.44 ( 46.81 ) 62.97 ( 54.14 )
19.6 54.88 ( 47.19 ) 61.74 ( 53.09 ) 54.79 ( 47.11 ) 61.47 ( 52.86 ) 54.72 ( 47.05 ) 63.29 ( 54.42 )
19.7 55.16 ( 47.43 ) 62.06 ( 53.36 ) 55.07 ( 47.35 ) 61.79 ( 53.13 ) 55.00 ( 47.29 ) 63.61 ( 54.70 )
19.8 55.44 ( 47.67 ) 62.37 ( 53.63 ) 55.35 ( 47.59 ) 62.10 ( 53.40 ) 55.27 ( 47.53 ) 63.94 ( 54.98 )
19.9 55.72 ( 47.91 ) 62.69 ( 53.90 ) 55.63 ( 47.83 ) 62.41 ( 53.67 ) 55.55 ( 47.77 ) 64.26 ( 55.25 )
20.0 56.00 ( 48.15 ) 63.00 ( 54.17 ) 55.91 ( 48.07 ) 62.73 ( 53.94 ) 55.83 ( 48.01 ) 64.58 ( 55.53 )
20.1 56.28 ( 48.39 ) 63.32 ( 54.44 ) 56.19 ( 48.31 ) 63.04 ( 54.21 ) 56.11 ( 48.25 ) 64.91 ( 55.81 )
20.2 56.56 ( 48.63 ) 63.63 ( 54.71 ) 56.47 ( 48.55 ) 63.35 ( 54.48 ) 56.39 ( 48.49 ) 65.23 ( 56.09 )
20.3 56.84 ( 48.87 ) 63.95 ( 54.98 ) 56.75 ( 48.79 ) 63.67 ( 54.74 ) 56.67 ( 48.73 ) 65.55 ( 56.36 )
20.4 57.12 ( 49.11 ) 64.26 ( 55.25 ) 57.03 ( 49.03 ) 63.98 ( 55.01 ) 56.95 ( 48.97 ) 65.87 ( 56.64 )
20.5 57.40 ( 49.36 ) 64.58 ( 55.52 ) 57.31 ( 49.27 ) 64.30 ( 55.28 ) 57.23 ( 49.21 ) 66.20 ( 56.92 )
20.6 57.68 ( 49.60 ) 64.89 ( 55.80 ) 57.59 ( 49.52 ) 64.61 ( 55.55 ) 57.51 ( 49.45 ) 66.52 ( 57.20 )
20.7 57.71 ( 49.62 ) 64.90 ( 55.81 ) 57.87 ( 49.76 ) 64.92 ( 55.82 ) 57.79 ( 49.69 ) 66.84 ( 57.48 )
20.8 57.74 ( 49.65 ) 64.91 ( 55.82 ) 58.15 ( 50.00 ) 65.24 ( 56.09 ) 58.07 ( 49.93 ) 67.17 ( 57.75 )
20.9 57.77 ( 49.68 ) 64.93 ( 55.83 ) 58.43 ( 50.24 ) 65.55 ( 56.36 ) 58.35 ( 50.17 ) 67.49 ( 58.03 )
21.0 57.80 ( 49.70 ) 64.94 ( 55.84 ) 58.70 ( 50.48 ) 65.86 ( 56.63 ) 58.63 ( 50.41 ) 67.81 ( 58.31 )
21.1 57.84 ( 49.73 ) 64.95 ( 55.85 ) 58.98 ( 50.72 ) 66.18 ( 56.90 ) 58.90 ( 50.65 ) 68.14 ( 58.59 )
21.2 57.87 ( 49.76 ) 64.96 ( 55.86 ) 59.26 ( 50.96 ) 66.49 ( 57.17 ) 59.18 ( 50.89 ) 68.46 ( 58.86 )
21.3 57.90 ( 49.78 ) 64.97 ( 55.87 ) 59.54 ( 51.20 ) 66.80 ( 57.44 ) 59.46 ( 51.13 ) 68.78 ( 59.14 )
21.4 57.93 ( 49.81 ) 64.98 ( 55.88 ) 59.82 ( 51.44 ) 67.12 ( 57.71 ) 59.74 ( 51.37 ) 69.10 ( 59.42 )
21.5 57.96 ( 49.84 ) 65.00 ( 55.89 ) 60.10 ( 51.68 ) 67.43 ( 57.98 ) 60.02 ( 51.61 ) 69.43 ( 59.70 )
21.6 57.99 ( 49.86 ) 65.01 ( 55.90 ) 60.38 ( 51.92 ) 67.75 ( 58.25 ) 60.30 ( 51.85 ) 69.75 ( 59.97 )
21.7 58.02 ( 49.89 ) 65.02 ( 55.91 ) 60.66 ( 52.16 ) 68.06 ( 58.52 ) 60.58 ( 52.09 ) 70.07 ( 60.25 )
21.8 58.05 ( 49.92 ) 65.03 ( 55.92 ) 60.94 ( 52.40 ) 68.37 ( 58.79 ) 60.86 ( 52.33 ) 70.40 ( 60.53 )
21.9 58.08 ( 49.94 ) 65.04 ( 55.93 ) 61.22 ( 52.64 ) 68.69 ( 59.06 ) 61.14 ( 52.57 ) 70.72 ( 60.81 )

FAN-2209 201709 1-75


SELECTION DATA

Table 8. Outdoor Unit Capacity (JTOR200~240VPE(U,F,R)BS1) with Total Horsepower of Combined Indoor Unit (3)
Total Outdoor Unit Capacity: kW (×1000kcal/h)
RAS-20FSXNS
JTOR200VPE(U,F,R)BS1 RAS-22FSXNS
JTOR220VPE(U,F,R)BS1 RAS-24FSXNS
JTOR240VPE(U,F,R)BS1
Cooling Heating Cooling Heating Cooling Heating
22.0 58.12 ( 49.97 ) 65.05 ( 55.94 ) 61.50 ( 52.88 ) 69.00 ( 59.33 ) 61.42 ( 52.81 ) 71.04 ( 61.08 )
22.1 58.15 ( 50.00 ) 65.07 ( 55.95 ) 61.78 ( 53.12 ) 69.31 ( 59.60 ) 61.70 ( 53.05 ) 71.36 ( 61.36 )
22.2 58.18 ( 50.02 ) 65.08 ( 55.96 ) 62.06 ( 53.36 ) 69.63 ( 59.87 ) 61.98 ( 53.29 ) 71.69 ( 61.64 )
22.3 58.21 ( 50.05 ) 65.09 ( 55.97 ) 62.34 ( 53.60 ) 69.94 ( 60.14 ) 62.25 ( 53.53 ) 72.01 ( 61.92 )
22.4 58.24 ( 50.08 ) 65.10 ( 55.98 ) 62.62 ( 53.84 ) 70.25 ( 60.41 ) 62.53 ( 53.77 ) 72.33 ( 62.20 )
22.5 58.27 ( 50.10 ) 65.11 ( 55.99 ) 62.90 ( 54.08 ) 70.57 ( 60.68 ) 62.81 ( 54.01 ) 72.66 ( 62.47 )
22.6 58.30 ( 50.13 ) 65.12 ( 56.00 ) 63.18 ( 54.32 ) 70.88 ( 60.95 ) 63.09 ( 54.25 ) 72.98 ( 62.75 )
22.7 58.33 ( 50.16 ) 65.14 ( 56.01 ) 63.36 ( 54.48 ) 71.07 ( 61.11 ) 63.37 ( 54.49 ) 73.30 ( 63.03 )
22.8 58.36 ( 50.18 ) 65.15 ( 56.02 ) 63.39 ( 54.50 ) 71.09 ( 61.12 ) 63.65 ( 54.73 ) 73.63 ( 63.31 )
22.9 58.40 ( 50.21 ) 65.16 ( 56.03 ) 63.42 ( 54.53 ) 71.10 ( 61.13 ) 63.93 ( 54.97 ) 73.95 ( 63.58 )
23.0 58.43 ( 50.24 ) 65.17 ( 56.04 ) 63.45 ( 54.56 ) 71.11 ( 61.14 ) 64.21 ( 55.21 ) 74.27 ( 63.86 )
23.1 58.46 ( 50.26 ) 65.18 ( 56.05 ) 63.48 ( 54.58 ) 71.12 ( 61.15 ) 64.49 ( 55.45 ) 74.59 ( 64.14 )
23.2 58.49 ( 50.29 ) 65.19 ( 56.06 ) 63.51 ( 54.61 ) 71.13 ( 61.16 ) 64.77 ( 55.69 ) 74.92 ( 64.42 )
23.3 58.52 ( 50.32 ) 65.21 ( 56.07 ) 63.54 ( 54.64 ) 71.14 ( 61.17 ) 65.05 ( 55.93 ) 75.24 ( 64.69 )
23.4 58.55 ( 50.34 ) 65.22 ( 56.08 ) 63.57 ( 54.66 ) 71.16 ( 61.18 ) 65.33 ( 56.17 ) 75.56 ( 64.97 )
23.5 58.58 ( 50.37 ) 65.23 ( 56.09 ) 63.61 ( 54.69 ) 71.17 ( 61.19 ) 65.60 ( 56.41 ) 75.89 ( 65.25 )
23.6 58.61 ( 50.40 ) 65.24 ( 56.10 ) 63.64 ( 54.72 ) 71.18 ( 61.20 ) 65.88 ( 56.65 ) 76.21 ( 65.53 )
23.7 58.64 ( 50.43 ) 65.25 ( 56.11 ) 63.67 ( 54.74 ) 71.19 ( 61.21 ) 66.16 ( 56.89 ) 76.53 ( 65.81 )
23.8 58.68 ( 50.45 ) 65.26 ( 56.12 ) 63.70 ( 54.77 ) 71.20 ( 61.22 ) 66.44 ( 57.13 ) 76.85 ( 66.08 )
23.9 58.71 ( 50.48 ) 65.28 ( 56.13 ) 63.73 ( 54.80 ) 71.21 ( 61.23 ) 66.72 ( 57.37 ) 77.18 ( 66.36 )
24.0 58.74 ( 50.51 ) 65.29 ( 56.14 ) 63.76 ( 54.82 ) 71.23 ( 61.24 ) 67.00 ( 57.61 ) 77.50 ( 66.64 )
24.1 58.77 ( 50.53 ) 65.30 ( 56.15 ) 63.79 ( 54.85 ) 71.24 ( 61.25 ) 67.03 ( 57.63 ) 77.52 ( 66.66 )
24.2 58.80 ( 50.56 ) 65.31 ( 56.16 ) 63.82 ( 54.88 ) 71.25 ( 61.26 ) 67.06 ( 57.66 ) 77.54 ( 66.68 )
24.3 58.83 ( 50.59 ) 65.32 ( 56.17 ) 63.85 ( 54.90 ) 71.26 ( 61.27 ) 67.08 ( 57.68 ) 77.56 ( 66.69 )
24.4 58.86 ( 50.61 ) 65.33 ( 56.18 ) 63.89 ( 54.93 ) 71.27 ( 61.28 ) 67.11 ( 57.71 ) 77.59 ( 66.71 )
24.5 58.89 ( 50.64 ) 65.35 ( 56.19 ) 63.92 ( 54.96 ) 71.28 ( 61.29 ) 67.14 ( 57.73 ) 77.61 ( 66.73 )
24.6 58.92 ( 50.67 ) 65.36 ( 56.20 ) 63.95 ( 54.99 ) 71.30 ( 61.30 ) 67.17 ( 57.75 ) 77.63 ( 66.75 )
24.7 58.96 ( 50.69 ) 65.37 ( 56.21 ) 63.98 ( 55.01 ) 71.31 ( 61.31 ) 67.20 ( 57.78 ) 77.65 ( 66.77 )
24.8 58.99 ( 50.72 ) 65.38 ( 56.22 ) 64.01 ( 55.04 ) 71.32 ( 61.32 ) 67.22 ( 57.80 ) 77.67 ( 66.79 )
24.9 59.02 ( 50.75 ) 65.39 ( 56.23 ) 64.04 ( 55.07 ) 71.33 ( 61.33 ) 67.25 ( 57.83 ) 77.69 ( 66.80 )
25.0 59.05 ( 50.77 ) 65.40 ( 56.24 ) 64.07 ( 55.09 ) 71.34 ( 61.34 ) 67.28 ( 57.85 ) 77.72 ( 66.82 )
25.1 59.08 ( 50.80 ) 65.42 ( 56.25 ) 64.10 ( 55.12 ) 71.35 ( 61.35 ) 67.31 ( 57.87 ) 77.74 ( 66.84 )
25.2 59.11 ( 50.83 ) 65.43 ( 56.26 ) 64.13 ( 55.15 ) 71.37 ( 61.36 ) 67.34 ( 57.90 ) 77.76 ( 66.86 )
25.3 59.14 ( 50.85 ) 65.44 ( 56.27 ) 64.17 ( 55.17 ) 71.38 ( 61.37 ) 67.36 ( 57.92 ) 77.78 ( 66.88 )
25.4 59.17 ( 50.88 ) 65.45 ( 56.28 ) 64.20 ( 55.20 ) 71.39 ( 61.38 ) 67.39 ( 57.95 ) 77.80 ( 66.90 )
25.5 59.20 ( 50.91 ) 65.46 ( 56.29 ) 64.23 ( 55.23 ) 71.40 ( 61.39 ) 67.42 ( 57.97 ) 77.82 ( 66.92 )
25.6 59.24 ( 50.93 ) 65.47 ( 56.30 ) 64.26 ( 55.25 ) 71.41 ( 61.40 ) 67.45 ( 57.99 ) 77.84 ( 66.93 )
25.7 59.27 ( 50.96 ) 65.49 ( 56.31 ) 64.29 ( 55.28 ) 71.42 ( 61.41 ) 67.47 ( 58.02 ) 77.87 ( 66.95 )
25.8 59.30 ( 50.99 ) 65.50 ( 56.32 ) 64.32 ( 55.31 ) 71.43 ( 61.42 ) 67.50 ( 58.04 ) 77.89 ( 66.97 )
25.9 59.33 ( 51.01 ) 65.51 ( 56.33 ) 64.35 ( 55.33 ) 71.45 ( 61.43 ) 67.53 ( 58.07 ) 77.91 ( 66.99 )
26.0 59.36 ( 51.04 ) 65.52 ( 56.34 ) 64.38 ( 55.36 ) 71.46 ( 61.44 ) 67.56 ( 58.09 ) 77.93 ( 67.01 )
26.1 64.41 ( 55.39 ) 71.47 ( 61.45 ) 67.59 ( 58.11 ) 77.95 ( 67.03 )
26.2 64.44 ( 55.41 ) 71.48 ( 61.46 ) 67.61 ( 58.14 ) 77.97 ( 67.05 )
26.3 64.48 ( 55.44 ) 71.49 ( 61.47 ) 67.64 ( 58.16 ) 78.00 ( 67.06 )
26.4 64.51 ( 55.47 ) 71.50 ( 61.48 ) 67.67 ( 58.19 ) 78.02 ( 67.08 )
26.5 64.54 ( 55.49 ) 71.52 ( 61.49 ) 67.70 ( 58.21 ) 78.04 ( 67.10 )
26.6 64.57 ( 55.52 ) 71.53 ( 61.50 ) 67.73 ( 58.23 ) 78.06 ( 67.12 )
26.7 64.60 ( 55.55 ) 71.54 ( 61.51 ) 67.75 ( 58.26 ) 78.08 ( 67.14 )
26.8 64.63 ( 55.57 ) 71.55 ( 61.52 ) 67.78 ( 58.28 ) 78.10 ( 67.16 )
26.9 64.66 ( 55.60 ) 71.56 ( 61.53 ) 67.81 ( 58.31 ) 78.12 ( 67.17 )
27.0 _ 64.69 ( 55.63 ) 71.57 ( 61.54 ) 67.84 ( 58.33 ) 78.15 ( 67.19 )
27.1 64.72 ( 55.65 ) 71.59 ( 61.55 ) 67.87 ( 58.35 ) 78.17 ( 67.21 )
27.2 64.76 ( 55.68 ) 71.60 ( 61.56 ) 67.89 ( 58.38 ) 78.19 ( 67.23 )
27.3 64.79 ( 55.71 ) 71.61 ( 61.57 ) 67.92 ( 58.40 ) 78.21 ( 67.25 )
27.4 64.82 ( 55.73 ) 71.62 ( 61.58 ) 67.95 ( 58.43 ) 78.23 ( 67.27 )
27.5 64.85 ( 55.76 ) 71.63 ( 61.59 ) 67.98 ( 58.45 ) 78.25 ( 67.29 )
27.6 64.88 ( 55.79 ) 71.64 ( 61.60 ) 68.01 ( 58.47 ) 78.28 ( 67.30 )
27.7 64.91 ( 55.81 ) 71.66 ( 61.61 ) 68.03 ( 58.50 ) 78.30 ( 67.32 )
27.8 64.94 ( 55.84 ) 71.67 ( 61.62 ) 68.06 ( 58.52 ) 78.32 ( 67.34 )
27.9 64.97 ( 55.87 ) 71.68 ( 61.63 ) 68.09 ( 58.55 ) 78.34 ( 67.36 )

1-76 FAN-2209 201709


SELECTION DATA

Table 9. Outdoor Unit Capacity (JTOR200~240VPE(U,F,R)BS1) with Total Horsepower of Combined Indoor Unit (4)
Total Outdoor Unit Capacity: kW (×1000kcal/h)
RAS-20FSXNS
JTOR200VPE(U,F,R)BS1 RAS-22FSXNS
JTOR220VPE(U,F,R)BS1 RAS-24FSXNS
JTOR240VPE(U,F,R)BS1
Cooling Heating Cooling Heating Cooling Heating
28.0 65.00 ( 55.89 ) 71.69 ( 61.64 ) 68.12 ( 58.57 ) 78.36 ( 67.38 )
28.1 65.03 ( 55.92 ) 71.70 ( 61.65 ) 68.14 ( 58.59 ) 78.38 ( 67.40 )
28.2 65.07 ( 55.95 ) 71.71 ( 61.66 ) 68.17 ( 58.62 ) 78.40 ( 67.42 )
28.3 65.10 ( 55.97 ) 71.73 ( 61.67 ) 68.20 ( 58.64 ) 78.43 ( 67.43 )
28.4 65.13 ( 56.00 ) 71.74 ( 61.68 ) 68.23 ( 58.67 ) 78.45 ( 67.45 )
28.5 65.16 ( 56.03 ) 71.75 ( 61.69 ) 68.26 ( 58.69 ) 78.47 ( 67.47 )
28.6 65.19 ( 56.05 ) 71.76 ( 61.70 ) 68.28 ( 58.71 ) 78.49 ( 67.49 )
28.7 68.31 ( 58.74 ) 78.51 ( 67.51 )
28.8 68.34 ( 58.76 ) 78.53 ( 67.53 )
28.9 68.37 ( 58.79 ) 78.55 ( 67.55 )
29.0 68.40 ( 58.81 ) 78.58 ( 67.56 )
29.1 68.42 ( 58.83 ) 78.60 ( 67.58 )
29.2 68.45 ( 58.86 ) 78.62 ( 67.60 )
29.3 68.48 ( 58.88 ) 78.64 ( 67.62 )
29.4 68.51 ( 58.91 ) 78.66 ( 67.64 )
29.5 68.54 ( 58.93 ) 78.68 ( 67.66 )
29.6 _ 68.56 ( 58.95 ) 78.71 ( 67.67 )
29.7 68.59 ( 58.98 ) 78.73 ( 67.69 )
29.8 68.62 ( 59.00 ) 78.75 ( 67.71 )
29.9 68.65 ( 59.03 ) 78.77 ( 67.73 )
_
30.0 68.68 ( 59.05 ) 78.79 ( 67.75 )
30.1 68.70 ( 59.07 ) 78.81 ( 67.77 )
30.2 68.73 ( 59.10 ) 78.83 ( 67.79 )
30.3 68.76 ( 59.12 ) 78.86 ( 67.80 )
30.4 68.79 ( 59.15 ) 78.88 ( 67.82 )
30.5 68.81 ( 59.17 ) 78.90 ( 67.84 )
30.6 68.84 ( 59.19 ) 78.92 ( 67.86 )
30.7 68.87 ( 59.22 ) 78.94 ( 67.88 )
30.8 68.90 ( 59.24 ) 78.96 ( 67.90 )
30.9 68.93 ( 59.27 ) 78.99 ( 67.92 )
31.0 68.95 ( 59.29 ) 79.01 ( 67.93 )
31.1 68.98 ( 59.31 ) 79.03 ( 67.95 )
31.2 69.01 ( 59.34 ) 79.05 ( 67.97 )

FAN-2209 201709 1-77


SELECTION DATA

Table 10. Outdoor Unit Capacity (JTOR260~300VAE(U,F,R)BS1) with Total Horsepower of Combined Indoor Unit (1)
Total Outdoor Unit Capacity: kW (×1000kcal/h)
RAS-26FSXNS
JTOR260VAE(U,F,R)BS1 RAS-28FSXNS
JTOR280VAE(U,F,R)BS1 RAS-30FSXNS
JTOR300VAE(U,F,R)BS1
Cooling Heating Cooling Heating Cooling Heating
13.0 36.50 ( 31.38 ) 41.25 ( 35.47 )
13.1 36.78 ( 31.63 ) 41.57 ( 35.74 )
13.2 37.06 ( 31.87 ) 41.88 ( 36.01 )
13.3 37.34 ( 32.11 ) 42.20 ( 36.29 )
13.4 37.62 ( 32.35 ) 42.52 ( 36.56 )
_
13.5 37.90 ( 32.59 ) 42.84 ( 36.83 )
13.6 38.18 ( 32.83 ) 43.15 ( 37.11 )
13.7 38.47 ( 33.07 ) 43.47 ( 37.38 )
13.8 38.75 ( 33.32 ) 43.79 ( 37.65 )
13.9 39.03 ( 33.56 ) 44.11 ( 37.92 )
_
14.0 39.31 ( 33.80 ) 44.42 ( 38.20 ) 38.75 ( 33.32 ) 45.00 ( 38.69 )
14.1 39.59 ( 34.04 ) 44.74 ( 38.47 ) 39.03 ( 33.56 ) 45.32 ( 38.97 )
14.2 39.87 ( 34.28 ) 45.06 ( 38.74 ) 39.30 ( 33.79 ) 45.64 ( 39.25 )
14.3 40.15 ( 34.52 ) 45.38 ( 39.02 ) 39.58 ( 34.03 ) 45.96 ( 39.52 )
14.4 40.43 ( 34.76 ) 45.69 ( 39.29 ) 39.86 ( 34.27 ) 46.29 ( 39.80 )
14.5 40.71 ( 35.01 ) 46.01 ( 39.56 ) 40.13 ( 34.51 ) 46.61 ( 40.07 )
14.6 40.99 ( 35.25 ) 46.33 ( 39.83 ) 40.41 ( 34.75 ) 46.93 ( 40.35 )
14.7 41.27 ( 35.49 ) 46.64 ( 40.11 ) 40.69 ( 34.98 ) 47.25 ( 40.63 )
14.8 41.55 ( 35.73 ) 46.96 ( 40.38 ) 40.96 ( 35.22 ) 47.57 ( 40.90 )
14.9 41.83 ( 35.97 ) 47.28 ( 40.65 ) 41.24 ( 35.46 ) 47.89 ( 41.18 )
15.0 42.12 ( 36.21 ) 47.60 ( 40.93 ) 41.52 ( 35.70 ) 48.21 ( 41.46 ) 42.50 ( 36.54 ) 47.50 ( 40.84 )
15.1 42.40 ( 36.45 ) 47.91 ( 41.20 ) 41.79 ( 35.94 ) 48.54 ( 41.73 ) 42.78 ( 36.79 ) 47.82 ( 41.11 )
15.2 42.68 ( 36.70 ) 48.23 ( 41.47 ) 42.07 ( 36.17 ) 48.86 ( 42.01 ) 43.07 ( 37.03 ) 48.13 ( 41.39 )
15.3 42.96 ( 36.94 ) 48.55 ( 41.74 ) 42.35 ( 36.41 ) 49.18 ( 42.29 ) 43.35 ( 37.27 ) 48.45 ( 41.66 )
15.4 43.24 ( 37.18 ) 48.87 ( 42.02 ) 42.62 ( 36.65 ) 49.50 ( 42.56 ) 43.63 ( 37.52 ) 48.77 ( 41.93 )
15.5 43.52 ( 37.42 ) 49.18 ( 42.29 ) 42.90 ( 36.89 ) 49.82 ( 42.84 ) 43.92 ( 37.76 ) 49.08 ( 42.20 )
15.6 43.80 ( 37.66 ) 49.50 ( 42.56 ) 43.18 ( 37.13 ) 50.14 ( 43.12 ) 44.20 ( 38.01 ) 49.40 ( 42.48 )
15.7 44.08 ( 37.90 ) 49.82 ( 42.84 ) 43.46 ( 37.36 ) 50.46 ( 43.39 ) 44.48 ( 38.25 ) 49.72 ( 42.75 )
15.8 44.36 ( 38.14 ) 50.13 ( 43.11 ) 43.73 ( 37.60 ) 50.79 ( 43.67 ) 44.77 ( 38.49 ) 50.03 ( 43.02 )
15.9 44.64 ( 38.39 ) 50.45 ( 43.38 ) 44.01 ( 37.84 ) 51.11 ( 43.94 ) 45.05 ( 38.74 ) 50.35 ( 43.29 )
16.0 44.92 ( 38.63 ) 50.77 ( 43.65 ) 44.29 ( 38.08 ) 51.43 ( 44.22 ) 45.33 ( 38.98 ) 50.67 ( 43.57 )
16.1 45.20 ( 38.87 ) 51.09 ( 43.93 ) 44.56 ( 38.32 ) 51.75 ( 44.50 ) 45.62 ( 39.22 ) 50.98 ( 43.84 )
16.2 45.48 ( 39.11 ) 51.40 ( 44.20 ) 44.84 ( 38.55 ) 52.07 ( 44.77 ) 45.90 ( 39.47 ) 51.30 ( 44.11 )
16.3 45.77 ( 39.35 ) 51.72 ( 44.47 ) 45.12 ( 38.79 ) 52.39 ( 45.05 ) 46.18 ( 39.71 ) 51.62 ( 44.38 )
16.4 46.05 ( 39.59 ) 52.04 ( 44.75 ) 45.39 ( 39.03 ) 52.71 ( 45.33 ) 46.47 ( 39.95 ) 51.93 ( 44.65 )
16.5 46.33 ( 39.83 ) 52.36 ( 45.02 ) 45.67 ( 39.27 ) 53.04 ( 45.60 ) 46.75 ( 40.20 ) 52.25 ( 44.93 )
16.6 46.61 ( 40.08 ) 52.67 ( 45.29 ) 45.95 ( 39.51 ) 53.36 ( 45.88 ) 47.03 ( 40.44 ) 52.57 ( 45.20 )
16.7 46.89 ( 40.32 ) 52.99 ( 45.56 ) 46.22 ( 39.74 ) 53.68 ( 46.16 ) 47.32 ( 40.69 ) 52.88 ( 45.47 )
16.8 47.17 ( 40.56 ) 53.31 ( 45.84 ) 46.50 ( 39.98 ) 54.00 ( 46.43 ) 47.60 ( 40.93 ) 53.20 ( 45.74 )
16.9 47.45 ( 40.80 ) 53.62 ( 46.11 ) 46.78 ( 40.22 ) 54.32 ( 46.71 ) 47.88 ( 41.17 ) 53.52 ( 46.02 )
17.0 47.73 ( 41.04 ) 53.94 ( 46.38 ) 47.05 ( 40.46 ) 54.64 ( 46.98 ) 48.17 ( 41.42 ) 53.83 ( 46.29 )
17.1 48.01 ( 41.28 ) 54.26 ( 46.65 ) 47.33 ( 40.70 ) 54.96 ( 47.26 ) 48.45 ( 41.66 ) 54.15 ( 46.56 )
17.2 48.29 ( 41.52 ) 54.58 ( 46.93 ) 47.61 ( 40.93 ) 55.29 ( 47.54 ) 48.73 ( 41.90 ) 54.47 ( 46.83 )
17.3 48.57 ( 41.77 ) 54.89 ( 47.20 ) 47.88 ( 41.17 ) 55.61 ( 47.81 ) 49.02 ( 42.15 ) 54.78 ( 47.11 )
17.4 48.85 ( 42.01 ) 55.21 ( 47.47 ) 48.16 ( 41.41 ) 55.93 ( 48.09 ) 49.30 ( 42.39 ) 55.10 ( 47.38 )
17.5 49.13 ( 42.25 ) 55.53 ( 47.75 ) 48.44 ( 41.65 ) 56.25 ( 48.37 ) 49.58 ( 42.63 ) 55.42 ( 47.65 )
17.6 49.42 ( 42.49 ) 55.85 ( 48.02 ) 48.71 ( 41.89 ) 56.57 ( 48.64 ) 49.87 ( 42.88 ) 55.73 ( 47.92 )
17.7 49.70 ( 42.73 ) 56.16 ( 48.29 ) 48.99 ( 42.12 ) 56.89 ( 48.92 ) 50.15 ( 43.12 ) 56.05 ( 48.19 )
17.8 49.98 ( 42.97 ) 56.48 ( 48.56 ) 49.27 ( 42.36 ) 57.21 ( 49.20 ) 50.43 ( 43.36 ) 56.37 ( 48.47 )
17.9 50.26 ( 43.21 ) 56.80 ( 48.84 ) 49.54 ( 42.60 ) 57.54 ( 49.47 ) 50.72 ( 43.61 ) 56.68 ( 48.74 )
18.0 50.54 ( 43.46 ) 57.12 ( 49.11 ) 49.82 ( 42.84 ) 57.86 ( 49.75 ) 51.00 ( 43.85 ) 57.00 ( 49.01 )
18.1 50.82 ( 43.70 ) 57.43 ( 49.38 ) 50.10 ( 43.08 ) 58.18 ( 50.02 ) 51.28 ( 44.10 ) 57.32 ( 49.28 )
18.2 51.10 ( 43.94 ) 57.75 ( 49.66 ) 50.37 ( 43.31 ) 58.50 ( 50.30 ) 51.57 ( 44.34 ) 57.63 ( 49.56 )
18.3 51.38 ( 44.18 ) 58.07 ( 49.93 ) 50.65 ( 43.55 ) 58.82 ( 50.58 ) 51.85 ( 44.58 ) 57.95 ( 49.83 )
18.4 51.66 ( 44.42 ) 58.38 ( 50.20 ) 50.93 ( 43.79 ) 59.14 ( 50.85 ) 52.13 ( 44.83 ) 58.27 ( 50.10 )
18.5 51.94 ( 44.66 ) 58.70 ( 50.47 ) 51.21 ( 44.03 ) 59.46 ( 51.13 ) 52.42 ( 45.07 ) 58.58 ( 50.37 )
18.6 52.22 ( 44.90 ) 59.02 ( 50.75 ) 51.48 ( 44.27 ) 59.79 ( 51.41 ) 52.70 ( 45.31 ) 58.90 ( 50.64 )
18.7 52.50 ( 45.15 ) 59.34 ( 51.02 ) 51.76 ( 44.50 ) 60.11 ( 51.68 ) 52.98 ( 45.56 ) 59.22 ( 50.92 )
18.8 52.78 ( 45.39 ) 59.65 ( 51.29 ) 52.04 ( 44.74 ) 60.43 ( 51.96 ) 53.27 ( 45.80 ) 59.53 ( 51.19 )
18.9 53.07 ( 45.63 ) 59.97 ( 51.57 ) 52.31 ( 44.98 ) 60.75 ( 52.24 ) 53.55 ( 46.04 ) 59.85 ( 51.46 )

1-78 FAN-2209 201709


SELECTION DATA

Table 11. Outdoor Unit Capacity (JTOR260~300VAE(U,F,R)BS1) with Total Horsepower of Combined Indoor Unit (2)
Total Outdoor Unit Capacity: kW (×1000kcal/h)
RAS-26FSXNS
JTOR260VAE(U,F,R)BS1 RAS-28FSXNS
JTOR280VAE(U,F,R)BS1 RAS-30FSXNS
JTOR300VAE(U,F,R)BS1
Cooling Heating Cooling Heating Cooling Heating
19.0 53.35 ( 45.87 ) 60.29 ( 51.84 ) 52.59 ( 45.22 ) 61.07 ( 52.51 ) 53.83 ( 46.29 ) 60.17 ( 51.73 )
19.1 53.63 ( 46.11 ) 60.61 ( 52.11 ) 52.87 ( 45.46 ) 61.39 ( 52.79 ) 54.12 ( 46.53 ) 60.48 ( 52.01 )
19.2 53.91 ( 46.35 ) 60.92 ( 52.38 ) 53.14 ( 45.69 ) 61.71 ( 53.06 ) 54.40 ( 46.78 ) 60.80 ( 52.28 )
19.3 54.19 ( 46.59 ) 61.24 ( 52.66 ) 53.42 ( 45.93 ) 62.04 ( 53.34 ) 54.68 ( 47.02 ) 61.12 ( 52.55 )
19.4 54.47 ( 46.84 ) 61.56 ( 52.93 ) 53.70 ( 46.17 ) 62.36 ( 53.62 ) 54.97 ( 47.26 ) 61.43 ( 52.82 )
19.5 54.75 ( 47.08 ) 61.87 ( 53.20 ) 53.97 ( 46.41 ) 62.68 ( 53.89 ) 55.25 ( 47.51 ) 61.75 ( 53.10 )
19.6 55.03 ( 47.32 ) 62.19 ( 53.48 ) 54.25 ( 46.65 ) 63.00 ( 54.17 ) 55.53 ( 47.75 ) 62.07 ( 53.37 )
19.7 55.31 ( 47.56 ) 62.51 ( 53.75 ) 54.53 ( 46.88 ) 63.32 ( 54.45 ) 55.82 ( 47.99 ) 62.38 ( 53.64 )
19.8 55.59 ( 47.80 ) 62.83 ( 54.02 ) 54.80 ( 47.12 ) 63.64 ( 54.72 ) 56.10 ( 48.24 ) 62.70 ( 53.91 )
19.9 55.87 ( 48.04 ) 63.14 ( 54.29 ) 55.08 ( 47.36 ) 63.96 ( 55.00 ) 56.38 ( 48.48 ) 63.02 ( 54.18 )
20.0 56.15 ( 48.28 ) 63.46 ( 54.57 ) 55.36 ( 47.60 ) 64.29 ( 55.28 ) 56.67 ( 48.72 ) 63.33 ( 54.46 )
20.1 56.43 ( 48.53 ) 63.78 ( 54.84 ) 55.63 ( 47.84 ) 64.61 ( 55.55 ) 56.95 ( 48.97 ) 63.65 ( 54.73 )
20.2 56.72 ( 48.77 ) 64.10 ( 55.11 ) 55.91 ( 48.07 ) 64.93 ( 55.83 ) 57.23 ( 49.21 ) 63.97 ( 55.00 )
20.3 57.00 ( 49.01 ) 64.41 ( 55.39 ) 56.19 ( 48.31 ) 65.25 ( 56.10 ) 57.52 ( 49.46 ) 64.28 ( 55.27 )
20.4 57.28 ( 49.25 ) 64.73 ( 55.66 ) 56.46 ( 48.55 ) 65.57 ( 56.38 ) 57.80 ( 49.70 ) 64.60 ( 55.55 )
20.5 57.56 ( 49.49 ) 65.05 ( 55.93 ) 56.74 ( 48.79 ) 65.89 ( 56.66 ) 58.08 ( 49.94 ) 64.92 ( 55.82 )
20.6 57.84 ( 49.73 ) 65.37 ( 56.20 ) 57.02 ( 49.03 ) 66.21 ( 56.93 ) 58.37 ( 50.19 ) 65.23 ( 56.09 )
20.7 58.12 ( 49.97 ) 65.68 ( 56.48 ) 57.29 ( 49.26 ) 66.54 ( 57.21 ) 58.65 ( 50.43 ) 65.55 ( 56.36 )
20.8 58.40 ( 50.21 ) 66.00 ( 56.75 ) 57.57 ( 49.50 ) 66.86 ( 57.49 ) 58.93 ( 50.67 ) 65.87 ( 56.64 )
20.9 58.68 ( 50.46 ) 66.32 ( 57.02 ) 57.85 ( 49.74 ) 67.18 ( 57.76 ) 59.22 ( 50.92 ) 66.18 ( 56.91 )
21.0 58.96 ( 50.70 ) 66.63 ( 57.30 ) 58.12 ( 49.98 ) 67.50 ( 58.04 ) 59.50 ( 51.16 ) 66.50 ( 57.18 )
21.1 59.24 ( 50.94 ) 66.95 ( 57.57 ) 58.40 ( 50.22 ) 67.82 ( 58.32 ) 59.78 ( 51.40 ) 66.82 ( 57.45 )
21.2 59.52 ( 51.18 ) 67.27 ( 57.84 ) 58.68 ( 50.45 ) 68.14 ( 58.59 ) 60.07 ( 51.65 ) 67.13 ( 57.72 )
21.3 59.80 ( 51.42 ) 67.59 ( 58.11 ) 58.96 ( 50.69 ) 68.46 ( 58.87 ) 60.35 ( 51.89 ) 67.45 ( 58.00 )
21.4 60.08 ( 51.66 ) 67.90 ( 58.39 ) 59.23 ( 50.93 ) 68.79 ( 59.15 ) 60.63 ( 52.14 ) 67.77 ( 58.27 )
21.5 60.37 ( 51.90 ) 68.22 ( 58.66 ) 59.51 ( 51.17 ) 69.11 ( 59.42 ) 60.92 ( 52.38 ) 68.08 ( 58.54 )
21.6 60.65 ( 52.15 ) 68.54 ( 58.93 ) 59.79 ( 51.41 ) 69.43 ( 59.70 ) 61.20 ( 52.62 ) 68.40 ( 58.81 )
21.7 60.93 ( 52.39 ) 68.86 ( 59.21 ) 60.06 ( 51.64 ) 69.75 ( 59.97 ) 61.48 ( 52.87 ) 68.72 ( 59.09 )
21.8 61.21 ( 52.63 ) 69.17 ( 59.48 ) 60.34 ( 51.88 ) 70.07 ( 60.25 ) 61.77 ( 53.11 ) 69.03 ( 59.36 )
21.9 61.49 ( 52.87 ) 69.49 ( 59.75 ) 60.62 ( 52.12 ) 70.39 ( 60.53 ) 62.05 ( 53.35 ) 69.35 ( 59.63 )
22.0 61.77 ( 53.11 ) 69.81 ( 60.02 ) 60.89 ( 52.36 ) 70.71 ( 60.80 ) 62.33 ( 53.60 ) 69.67 ( 59.90 )
22.1 62.05 ( 53.35 ) 70.13 ( 60.30 ) 61.17 ( 52.60 ) 71.04 ( 61.08 ) 62.62 ( 53.84 ) 69.98 ( 60.17 )
22.2 62.33 ( 53.59 ) 70.44 ( 60.57 ) 61.45 ( 52.83 ) 71.36 ( 61.36 ) 62.90 ( 54.08 ) 70.30 ( 60.45 )
22.3 62.61 ( 53.84 ) 70.76 ( 60.84 ) 61.72 ( 53.07 ) 71.68 ( 61.63 ) 63.18 ( 54.33 ) 70.62 ( 60.72 )
22.4 62.89 ( 54.08 ) 71.08 ( 61.12 ) 62.00 ( 53.31 ) 72.00 ( 61.91 ) 63.47 ( 54.57 ) 70.93 ( 60.99 )
22.5 63.17 ( 54.32 ) 71.39 ( 61.39 ) 62.28 ( 53.55 ) 72.32 ( 62.19 ) 63.75 ( 54.82 ) 71.25 ( 61.26 )
22.6 63.45 ( 54.56 ) 71.71 ( 61.66 ) 62.55 ( 53.79 ) 72.64 ( 62.46 ) 64.03 ( 55.06 ) 71.57 ( 61.54 )
22.7 63.73 ( 54.80 ) 72.03 ( 61.93 ) 62.83 ( 54.02 ) 72.96 ( 62.74 ) 64.32 ( 55.30 ) 71.88 ( 61.81 )
22.8 64.02 ( 55.04 ) 72.35 ( 62.21 ) 63.11 ( 54.26 ) 73.29 ( 63.01 ) 64.60 ( 55.55 ) 72.20 ( 62.08 )
22.9 64.30 ( 55.28 ) 72.66 ( 62.48 ) 63.38 ( 54.50 ) 73.61 ( 63.29 ) 64.88 ( 55.79 ) 72.52 ( 62.35 )
23.0 64.58 ( 55.53 ) 72.98 ( 62.75 ) 63.66 ( 54.74 ) 73.93 ( 63.57 ) 65.17 ( 56.03 ) 72.83 ( 62.63 )
23.1 64.86 ( 55.77 ) 73.30 ( 63.03 ) 63.94 ( 54.98 ) 74.25 ( 63.84 ) 65.45 ( 56.28 ) 73.15 ( 62.90 )
23.2 65.14 ( 56.01 ) 73.62 ( 63.30 ) 64.21 ( 55.21 ) 74.57 ( 64.12 ) 65.73 ( 56.52 ) 73.47 ( 63.17 )
23.3 65.42 ( 56.25 ) 73.93 ( 63.57 ) 64.49 ( 55.45 ) 74.89 ( 64.40 ) 66.02 ( 56.76 ) 73.78 ( 63.44 )
23.4 65.70 ( 56.49 ) 74.25 ( 63.84 ) 64.77 ( 55.69 ) 75.21 ( 64.67 ) 66.30 ( 57.01 ) 74.10 ( 63.71 )
23.5 65.98 ( 56.73 ) 74.57 ( 64.12 ) 65.04 ( 55.93 ) 75.54 ( 64.95 ) 66.58 ( 57.25 ) 74.42 ( 63.99 )
23.6 66.26 ( 56.97 ) 74.88 ( 64.39 ) 65.32 ( 56.17 ) 75.86 ( 65.23 ) 66.87 ( 57.49 ) 74.73 ( 64.26 )
23.7 66.54 ( 57.22 ) 75.20 ( 64.66 ) 65.60 ( 56.40 ) 76.18 ( 65.50 ) 67.15 ( 57.74 ) 75.05 ( 64.53 )
23.8 66.82 ( 57.46 ) 75.52 ( 64.93 ) 65.87 ( 56.64 ) 76.50 ( 65.78 ) 67.43 ( 57.98 ) 75.37 ( 64.80 )
23.9 67.10 ( 57.70 ) 75.84 ( 65.21 ) 66.15 ( 56.88 ) 76.82 ( 66.05 ) 67.72 ( 58.23 ) 75.68 ( 65.08 )
24.0 67.38 ( 57.94 ) 76.15 ( 65.48 ) 66.43 ( 57.12 ) 77.14 ( 66.33 ) 68.00 ( 58.47 ) 76.00 ( 65.35 )
24.1 67.67 ( 58.18 ) 76.47 ( 65.75 ) 66.71 ( 57.36 ) 77.46 ( 66.61 ) 68.28 ( 58.71 ) 76.32 ( 65.62 )
24.2 67.95 ( 58.42 ) 76.79 ( 66.03 ) 66.98 ( 57.59 ) 77.79 ( 66.88 ) 68.57 ( 58.96 ) 76.63 ( 65.89 )
24.3 68.23 ( 58.66 ) 77.11 ( 66.30 ) 67.26 ( 57.83 ) 78.11 ( 67.16 ) 68.85 ( 59.20 ) 76.95 ( 66.17 )
24.4 68.51 ( 58.91 ) 77.42 ( 66.57 ) 67.54 ( 58.07 ) 78.43 ( 67.44 ) 69.13 ( 59.44 ) 77.27 ( 66.44 )
24.5 68.79 ( 59.15 ) 77.74 ( 66.84 ) 67.81 ( 58.31 ) 78.75 ( 67.71 ) 69.42 ( 59.69 ) 77.58 ( 66.71 )
24.6 69.07 ( 59.39 ) 78.06 ( 67.12 ) 68.09 ( 58.55 ) 79.07 ( 67.99 ) 69.70 ( 59.93 ) 77.90 ( 66.98 )
24.7 69.35 ( 59.63 ) 78.38 ( 67.39 ) 68.37 ( 58.78 ) 79.39 ( 68.27 ) 69.98 ( 60.17 ) 78.22 ( 67.25 )
24.8 69.63 ( 59.87 ) 78.69 ( 67.66 ) 68.64 ( 59.02 ) 79.71 ( 68.54 ) 70.27 ( 60.42 ) 78.53 ( 67.53 )
24.9 69.91 ( 60.11 ) 79.01 ( 67.94 ) 68.92 ( 59.26 ) 80.04 ( 68.82 ) 70.55 ( 60.66 ) 78.85 ( 67.80 )

FAN-2209 201709 1-79


SELECTION DATA

Table 12. Outdoor Unit Capacity (JTOR260~300VAE(U,F,R)BS1) with Total Horsepower of Combined Indoor Unit (3)
Total Outdoor Unit Capacity: kW (×1000kcal/h)
RAS-26FSXNS
JTOR260VAE(U,F,R)BS1 RAS-28FSXNS
JTOR280VAE(U,F,R)BS1 RAS-30FSXNS
JTOR300VAE(U,F,R)BS1
Cooling Heating Cooling Heating Cooling Heating
25.0 70.19 ( 60.35 ) 79.33 ( 68.21 ) 69.20 ( 59.50 ) 80.36 ( 69.09 ) 70.83 ( 60.91 ) 79.17 ( 68.07 )
25.1 70.47 ( 60.60 ) 79.64 ( 68.48 ) 69.47 ( 59.74 ) 80.68 ( 69.37 ) 71.12 ( 61.15 ) 79.48 ( 68.34 )
25.2 70.75 ( 60.84 ) 79.96 ( 68.75 ) 69.75 ( 59.97 ) 81.00 ( 69.65 ) 71.40 ( 61.39 ) 79.80 ( 68.62 )
25.3 71.03 ( 61.08 ) 80.28 ( 69.03 ) 70.03 ( 60.21 ) 81.32 ( 69.92 ) 71.68 ( 61.64 ) 80.12 ( 68.89 )
25.4 71.32 ( 61.32 ) 80.60 ( 69.30 ) 70.30 ( 60.45 ) 81.64 ( 70.20 ) 71.97 ( 61.88 ) 80.43 ( 69.16 )
25.5 71.60 ( 61.56 ) 80.91 ( 69.57 ) 70.58 ( 60.69 ) 81.96 ( 70.48 ) 72.25 ( 62.12 ) 80.75 ( 69.43 )
25.6 71.88 ( 61.80 ) 81.23 ( 69.85 ) 70.86 ( 60.93 ) 82.29 ( 70.75 ) 72.53 ( 62.37 ) 81.07 ( 69.70 )
25.7 72.16 ( 62.04 ) 81.55 ( 70.12 ) 71.13 ( 61.16 ) 82.61 ( 71.03 ) 72.82 ( 62.61 ) 81.38 ( 69.98 )
25.8 72.44 ( 62.29 ) 81.87 ( 70.39 ) 71.41 ( 61.40 ) 82.93 ( 71.31 ) 73.10 ( 62.85 ) 81.70 ( 70.25 )
25.9 72.72 ( 62.53 ) 82.18 ( 70.66 ) 71.69 ( 61.64 ) 83.25 ( 71.58 ) 73.38 ( 63.10 ) 82.02 ( 70.52 )
26.0 73.00 ( 62.77 ) 82.50 ( 70.94 ) 71.96 ( 61.88 ) 83.57 ( 71.86 ) 73.67 ( 63.34 ) 82.33 ( 70.79 )
26.1 73.28 ( 63.01 ) 82.82 ( 71.21 ) 72.24 ( 62.12 ) 83.89 ( 72.13 ) 73.95 ( 63.59 ) 82.65 ( 71.07 )
26.2 73.56 ( 63.25 ) 83.13 ( 71.48 ) 72.52 ( 62.35 ) 84.21 ( 72.41 ) 74.23 ( 63.83 ) 82.97 ( 71.34 )
26.3 73.84 ( 63.49 ) 83.45 ( 71.76 ) 72.79 ( 62.59 ) 84.54 ( 72.69 ) 74.52 ( 64.07 ) 83.28 ( 71.61 )
26.4 74.12 ( 63.73 ) 83.77 ( 72.03 ) 73.07 ( 62.83 ) 84.86 ( 72.96 ) 74.80 ( 64.32 ) 83.60 ( 71.88 )
26.5 74.40 ( 63.98 ) 84.09 ( 72.30 ) 73.35 ( 63.07 ) 85.18 ( 73.24 ) 75.08 ( 64.56 ) 83.92 ( 72.16 )
26.6 74.68 ( 64.22 ) 84.40 ( 72.57 ) 73.62 ( 63.31 ) 85.50 ( 73.52 ) 75.37 ( 64.80 ) 84.23 ( 72.43 )
26.7 74.97 ( 64.46 ) 84.72 ( 72.85 ) 73.90 ( 63.54 ) 85.82 ( 73.79 ) 75.65 ( 65.05 ) 84.55 ( 72.70 )
26.8 75.20 ( 64.66 ) 84.98 ( 73.07 ) 74.18 ( 63.78 ) 86.14 ( 74.07 ) 75.93 ( 65.29 ) 84.87 ( 72.97 )
26.9 75.23 ( 64.68 ) 84.99 ( 73.08 ) 74.46 ( 64.02 ) 86.46 ( 74.35 ) 76.22 ( 65.53 ) 85.18 ( 73.24 )
27.0 75.26 ( 64.71 ) 85.00 ( 73.09 ) 74.73 ( 64.26 ) 86.79 ( 74.62 ) 76.50 ( 65.78 ) 85.50 ( 73.52 )
27.1 75.29 ( 64.74 ) 85.01 ( 73.10 ) 75.01 ( 64.50 ) 87.11 ( 74.90 ) 76.78 ( 66.02 ) 85.82 ( 73.79 )
27.2 75.32 ( 64.76 ) 85.02 ( 73.11 ) 75.29 ( 64.73 ) 87.43 ( 75.18 ) 77.07 ( 66.27 ) 86.13 ( 74.06 )
27.3 75.35 ( 64.79 ) 85.04 ( 73.12 ) 75.56 ( 64.97 ) 87.75 ( 75.45 ) 77.35 ( 66.51 ) 86.45 ( 74.33 )
27.4 75.38 ( 64.82 ) 85.05 ( 73.13 ) 75.84 ( 65.21 ) 88.07 ( 75.73 ) 77.63 ( 66.75 ) 86.77 ( 74.61 )
27.5 75.41 ( 64.84 ) 85.06 ( 73.14 ) 76.12 ( 65.45 ) 88.39 ( 76.00 ) 77.92 ( 67.00 ) 87.08 ( 74.88 )
27.6 75.45 ( 64.87 ) 85.07 ( 73.15 ) 76.39 ( 65.69 ) 88.71 ( 76.28 ) 78.20 ( 67.24 ) 87.40 ( 75.15 )
27.7 75.48 ( 64.90 ) 85.08 ( 73.16 ) 76.67 ( 65.92 ) 89.04 ( 76.56 ) 78.48 ( 67.48 ) 87.72 ( 75.42 )
27.8 75.51 ( 64.93 ) 85.09 ( 73.17 ) 76.95 ( 66.16 ) 89.36 ( 76.83 ) 78.77 ( 67.73 ) 88.03 ( 75.70 )
27.9 75.54 ( 64.95 ) 85.11 ( 73.18 ) 77.22 ( 66.40 ) 89.68 ( 77.11 ) 79.05 ( 67.97 ) 88.35 ( 75.97 )
28.0 75.57 ( 64.98 ) 85.12 ( 73.19 ) 77.50 ( 66.64 ) 90.00 ( 77.39 ) 79.33 ( 68.21 ) 88.67 ( 76.24 )
28.1 75.60 ( 65.01 ) 85.13 ( 73.20 ) 77.78 ( 66.88 ) 90.32 ( 77.66 ) 79.62 ( 68.46 ) 88.98 ( 76.51 )
28.2 75.63 ( 65.03 ) 85.14 ( 73.21 ) 78.05 ( 67.11 ) 90.64 ( 77.94 ) 79.90 ( 68.70 ) 89.30 ( 76.78 )
28.3 75.66 ( 65.06 ) 85.15 ( 73.22 ) 78.33 ( 67.35 ) 90.96 ( 78.22 ) 80.18 ( 68.95 ) 89.62 ( 77.06 )
28.4 75.70 ( 65.09 ) 85.17 ( 73.23 ) 78.61 ( 67.59 ) 91.29 ( 78.49 ) 80.47 ( 69.19 ) 89.93 ( 77.33 )
28.5 75.73 ( 65.11 ) 85.18 ( 73.24 ) 78.88 ( 67.83 ) 91.61 ( 78.77 ) 80.75 ( 69.43 ) 90.25 ( 77.60 )
28.6 75.76 ( 65.14 ) 85.19 ( 73.25 ) 79.16 ( 68.07 ) 91.93 ( 79.04 ) 81.03 ( 69.68 ) 90.57 ( 77.87 )
28.7 75.79 ( 65.17 ) 85.20 ( 73.26 ) 79.44 ( 68.30 ) 92.25 ( 79.32 ) 81.32 ( 69.92 ) 90.88 ( 78.15 )
28.8 75.82 ( 65.19 ) 85.21 ( 73.27 ) 79.71 ( 68.54 ) 92.57 ( 79.60 ) 81.60 ( 70.16 ) 91.20 ( 78.42 )
28.9 75.85 ( 65.22 ) 85.22 ( 73.28 ) 79.84 ( 68.65 ) 92.71 ( 79.71 ) 81.88 ( 70.41 ) 91.52 ( 78.69 )
29.0 75.88 ( 65.25 ) 85.24 ( 73.29 ) 79.87 ( 68.68 ) 92.72 ( 79.72 ) 82.17 ( 70.65 ) 91.83 ( 78.96 )
29.1 75.91 ( 65.27 ) 85.25 ( 73.30 ) 79.90 ( 68.71 ) 92.73 ( 79.73 ) 82.45 ( 70.89 ) 92.15 ( 79.23 )
29.2 75.94 ( 65.30 ) 85.26 ( 73.31 ) 79.94 ( 68.73 ) 92.74 ( 79.74 ) 82.73 ( 71.14 ) 92.47 ( 79.51 )
29.3 75.98 ( 65.33 ) 85.27 ( 73.32 ) 79.97 ( 68.76 ) 92.75 ( 79.75 ) 83.02 ( 71.38 ) 92.78 ( 79.78 )
29.4 76.01 ( 65.35 ) 85.28 ( 73.33 ) 80.00 ( 68.79 ) 92.77 ( 79.76 ) 83.30 ( 71.63 ) 93.10 ( 80.05 )
29.5 76.04 ( 65.38 ) 85.29 ( 73.34 ) 80.03 ( 68.81 ) 92.78 ( 79.78 ) 83.58 ( 71.87 ) 93.42 ( 80.32 )
29.6 76.07 ( 65.41 ) 85.31 ( 73.35 ) 80.06 ( 68.84 ) 92.79 ( 79.79 ) 83.87 ( 72.11 ) 93.73 ( 80.60 )
29.7 76.10 ( 65.44 ) 85.32 ( 73.36 ) 80.09 ( 68.86 ) 92.80 ( 79.80 ) 84.15 ( 72.36 ) 94.05 ( 80.87 )
29.8 76.13 ( 65.46 ) 85.33 ( 73.37 ) 80.12 ( 68.89 ) 92.81 ( 79.81 ) 84.43 ( 72.60 ) 94.37 ( 81.14 )
29.9 76.16 ( 65.49 ) 85.34 ( 73.38 ) 80.15 ( 68.92 ) 92.83 ( 79.82 ) 84.72 ( 72.84 ) 94.68 ( 81.41 )
30.0 76.19 ( 65.52 ) 85.35 ( 73.39 ) 80.18 ( 68.94 ) 92.84 ( 79.83 ) 85.00 ( 73.09 ) 95.00 ( 81.69 )
30.1 76.23 ( 65.54 ) 85.37 ( 73.40 ) 80.21 ( 68.97 ) 92.85 ( 79.84 ) 85.03 ( 73.11 ) 95.02 ( 81.70 )
30.2 76.26 ( 65.57 ) 85.38 ( 73.41 ) 80.24 ( 69.00 ) 92.86 ( 79.85 ) 85.06 ( 73.14 ) 95.04 ( 81.72 )
30.3 76.29 ( 65.60 ) 85.39 ( 73.42 ) 80.27 ( 69.02 ) 92.87 ( 79.86 ) 85.09 ( 73.16 ) 95.06 ( 81.74 )
30.4 76.32 ( 65.62 ) 85.40 ( 73.43 ) 80.30 ( 69.05 ) 92.89 ( 79.87 ) 85.11 ( 73.18 ) 95.08 ( 81.76 )
30.5 76.35 ( 65.65 ) 85.41 ( 73.44 ) 80.34 ( 69.08 ) 92.90 ( 79.88 ) 85.14 ( 73.21 ) 95.11 ( 81.78 )
30.6 76.38 ( 65.68 ) 85.42 ( 73.45 ) 80.37 ( 69.10 ) 92.91 ( 79.89 ) 85.17 ( 73.23 ) 95.13 ( 81.79 )
30.7 76.41 ( 65.70 ) 85.44 ( 73.46 ) 80.40 ( 69.13 ) 92.92 ( 79.90 ) 85.20 ( 73.26 ) 95.15 ( 81.81 )
30.8 76.44 ( 65.73 ) 85.45 ( 73.47 ) 80.43 ( 69.16 ) 92.93 ( 79.91 ) 85.23 ( 73.28 ) 95.17 ( 81.83 )
30.9 76.48 ( 65.76 ) 85.46 ( 73.48 ) 80.46 ( 69.18 ) 92.95 ( 79.92 ) 85.26 ( 73.31 ) 95.19 ( 81.85 )

1-80 FAN-2209 201709


SELECTION DATA

Table 13. Outdoor Unit Capacity (JTOR260~300VAE(U,F,R)BS1) with Total Horsepower of Combined Indoor Unit (4)
Total Outdoor Unit Capacity: kW (×1000kcal/h)
RAS-26FSXNS
JTOR260VAE(U,F,R)BS1 RAS-28FSXNS
JTOR280VAE(U,F,R)BS1 RAS-30FSXNS
JTOR300VAE(U,F,R)BS1
Cooling Heating Cooling Heating Cooling Heating
31.0 76.51 ( 65.78 ) 85.47 ( 73.49 ) 80.49 ( 69.21 ) 92.96 ( 79.93 ) 85.28 ( 73.33 ) 95.21 ( 81.87 )
31.1 76.54 ( 65.81 ) 85.48 ( 73.50 ) 80.52 ( 69.23 ) 92.97 ( 79.94 ) 85.31 ( 73.35 ) 95.23 ( 81.88 )
31.2 76.57 ( 65.84 ) 85.49 ( 73.51 ) 80.55 ( 69.26 ) 92.98 ( 79.95 ) 85.34 ( 73.38 ) 95.25 ( 81.90 )
31.3 76.60 ( 65.86 ) 85.51 ( 73.52 ) 80.58 ( 69.29 ) 92.99 ( 79.96 ) 85.37 ( 73.40 ) 95.27 ( 81.92 )
31.4 76.63 ( 65.89 ) 85.52 ( 73.53 ) 80.61 ( 69.31 ) 93.00 ( 79.97 ) 85.40 ( 73.43 ) 95.30 ( 81.94 )
31.5 76.66 ( 65.92 ) 85.53 ( 73.54 ) 80.64 ( 69.34 ) 93.02 ( 79.98 ) 85.43 ( 73.45 ) 95.32 ( 81.96 )
31.6 76.69 ( 65.94 ) 85.54 ( 73.55 ) 80.67 ( 69.37 ) 93.03 ( 79.99 ) 85.45 ( 73.48 ) 95.34 ( 81.98 )
31.7 76.72 ( 65.97 ) 85.55 ( 73.56 ) 80.70 ( 69.39 ) 93.04 ( 80.00 ) 85.48 ( 73.50 ) 95.36 ( 81.99 )
31.8 76.76 ( 66.00 ) 85.56 ( 73.57 ) 80.74 ( 69.42 ) 93.05 ( 80.01 ) 85.51 ( 73.53 ) 95.38 ( 82.01 )
31.9 76.79 ( 66.03 ) 85.58 ( 73.58 ) 80.77 ( 69.45 ) 93.06 ( 80.02 ) 85.54 ( 73.55 ) 95.40 ( 82.03 )
32.0 76.82 ( 66.05 ) 85.59 ( 73.59 ) 80.80 ( 69.47 ) 93.08 ( 80.03 ) 85.57 ( 73.57 ) 95.42 ( 82.05 )
32.1 76.85 ( 66.08 ) 85.60 ( 73.60 ) 80.83 ( 69.50 ) 93.09 ( 80.04 ) 85.60 ( 73.60 ) 95.44 ( 82.07 )
32.2 76.88 ( 66.11 ) 85.61 ( 73.61 ) 80.86 ( 69.53 ) 93.10 ( 80.05 ) 85.62 ( 73.62 ) 95.46 ( 82.08 )
32.3 76.91 ( 66.13 ) 85.62 ( 73.62 ) 80.89 ( 69.55 ) 93.11 ( 80.06 ) 85.65 ( 73.65 ) 95.49 ( 82.10 )
32.4 76.94 ( 66.16 ) 85.64 ( 73.63 ) 80.92 ( 69.58 ) 93.12 ( 80.07 ) 85.68 ( 73.67 ) 95.51 ( 82.12 )
32.5 76.97 ( 66.19 ) 85.65 ( 73.64 ) 80.95 ( 69.60 ) 93.14 ( 80.08 ) 85.71 ( 73.70 ) 95.53 ( 82.14 )
32.6 77.01 ( 66.21 ) 85.66 ( 73.65 ) 80.98 ( 69.63 ) 93.15 ( 80.09 ) 85.74 ( 73.72 ) 95.55 ( 82.16 )
32.7 77.04 ( 66.24 ) 85.67 ( 73.66 ) 81.01 ( 69.66 ) 93.16 ( 80.10 ) 85.77 ( 73.74 ) 95.57 ( 82.18 )
32.8 77.07 ( 66.27 ) 85.68 ( 73.67 ) 81.04 ( 69.68 ) 93.17 ( 80.11 ) 85.79 ( 73.77 ) 95.59 ( 82.19 )
32.9 77.10 ( 66.29 ) 85.69 ( 73.68 ) 81.07 ( 69.71 ) 93.18 ( 80.12 ) 85.82 ( 73.79 ) 95.61 ( 82.21 )
33.0 77.13 ( 66.32 ) 85.71 ( 73.69 ) 81.10 ( 69.74 ) 93.20 ( 80.13 ) 85.85 ( 73.82 ) 95.63 ( 82.23 )
33.1 77.16 ( 66.35 ) 85.72 ( 73.70 ) 81.14 ( 69.76 ) 93.21 ( 80.14 ) 85.88 ( 73.84 ) 95.65 ( 82.25 )
33.2 77.19 ( 66.37 ) 85.73 ( 73.71 ) 81.17 ( 69.79 ) 93.22 ( 80.15 ) 85.91 ( 73.87 ) 95.68 ( 82.27 )
33.3 77.22 ( 66.40 ) 85.74 ( 73.72 ) 81.20 ( 69.82 ) 93.23 ( 80.16 ) 85.94 ( 73.89 ) 95.70 ( 82.28 )
33.4 77.26 ( 66.43 ) 85.75 ( 73.73 ) 81.23 ( 69.84 ) 93.24 ( 80.17 ) 85.96 ( 73.92 ) 95.72 ( 82.30 )
33.5 77.29 ( 66.45 ) 85.76 ( 73.74 ) 81.26 ( 69.87 ) 93.25 ( 80.18 ) 85.99 ( 73.94 ) 95.74 ( 82.32 )
33.6 77.32 ( 66.48 ) 85.78 ( 73.75 ) 81.29 ( 69.90 ) 93.27 ( 80.19 ) 86.02 ( 73.96 ) 95.76 ( 82.34 )
33.7 77.35 ( 66.51 ) 85.79 ( 73.76 ) 81.32 ( 69.92 ) 93.28 ( 80.21 ) 86.05 ( 73.99 ) 95.78 ( 82.36 )
33.8 77.38 ( 66.53 ) 85.80 ( 73.77 ) 81.35 ( 69.95 ) 93.29 ( 80.22 ) 86.08 ( 74.01 ) 95.80 ( 82.38 )
33.9 81.38 ( 69.98 ) 93.30 ( 80.23 ) 86.11 ( 74.04 ) 95.82 ( 82.39 )
34.0 81.41 ( 70.00 ) 93.31 ( 80.24 ) 86.13 ( 74.06 ) 95.84 ( 82.41 )
34.1 81.44 ( 70.03 ) 93.33 ( 80.25 ) 86.16 ( 74.09 ) 95.87 ( 82.43 )
34.2 81.47 ( 70.05 ) 93.34 ( 80.26 ) 86.19 ( 74.11 ) 95.89 ( 82.45 )
34.3 81.50 ( 70.08 ) 93.35 ( 80.27 ) 86.22 ( 74.13 ) 95.91 ( 82.47 )
34.4 81.53 ( 70.11 ) 93.36 ( 80.28 ) 86.25 ( 74.16 ) 95.93 ( 82.48 )
34.5 81.57 ( 70.13 ) 93.37 ( 80.29 ) 86.28 ( 74.18 ) 95.95 ( 82.50 )
34.6 81.60 ( 70.16 ) 93.39 ( 80.30 ) 86.30 ( 74.21 ) 95.97 ( 82.52 )
34.7 81.63 ( 70.19 ) 93.40 ( 80.31 ) 86.33 ( 74.23 ) 95.99 ( 82.54 )
34.8 81.66 ( 70.21 ) 93.41 ( 80.32 ) 86.36 ( 74.26 ) 96.01 ( 82.56 )
34.9 81.69 ( 70.24 ) 93.42 ( 80.33 ) 86.39 ( 74.28 ) 96.03 ( 82.57 )
35.0 81.72 ( 70.27 ) 93.43 ( 80.34 ) 86.42 ( 74.30 ) 96.06 ( 82.59 )
35.1 81.75 ( 70.29 ) 93.45 ( 80.35 ) 86.45 ( 74.33 ) 96.08 ( 82.61 )
35.2 81.78 ( 70.32 ) 93.46 ( 80.36 ) 86.47 ( 74.35 ) 96.10 ( 82.63 )
35.3 81.81 ( 70.35 ) 93.47 ( 80.37 ) 86.50 ( 74.38 ) 96.12 ( 82.65 )
35.4 _ 81.84 ( 70.37 ) 93.48 ( 80.38 ) 86.53 ( 74.40 ) 96.14 ( 82.67 )
35.5 81.87 ( 70.40 ) 93.49 ( 80.39 ) 86.56 ( 74.43 ) 96.16 ( 82.68 )
35.6 81.90 ( 70.42 ) 93.50 ( 80.40 ) 86.59 ( 74.45 ) 96.18 ( 82.70 )
35.7 81.93 ( 70.45 ) 93.52 ( 80.41 ) 86.62 ( 74.48 ) 96.20 ( 82.72 )
35.8 81.97 ( 70.48 ) 93.53 ( 80.42 ) 86.64 ( 74.50 ) 96.22 ( 82.74 )
35.9 82.00 ( 70.50 ) 93.54 ( 80.43 ) 86.67 ( 74.52 ) 96.25 ( 82.76 )
36.0 82.03 ( 70.53 ) 93.55 ( 80.44 ) 86.70 ( 74.55 ) 96.27 ( 82.77 )
36.1 82.06 ( 70.56 ) 93.56 ( 80.45 ) 86.73 ( 74.57 ) 96.29 ( 82.79 )
36.2 82.09 ( 70.58 ) 93.58 ( 80.46 ) 86.76 ( 74.60 ) 96.31 ( 82.81 )
36.3 82.12 ( 70.61 ) 93.59 ( 80.47 ) 86.79 ( 74.62 ) 96.33 ( 82.83 )
36.4 82.15 ( 70.64 ) 93.60 ( 80.48 ) 86.81 ( 74.65 ) 96.35 ( 82.85 )
36.5 86.84 ( 74.67 ) 96.37 ( 82.87 )
36.6 86.87 ( 74.69 ) 96.39 ( 82.88 )
36.7 _ 86.90 ( 74.72 ) 96.41 ( 82.90 )
36.8 86.93 ( 74.74 ) 96.44 ( 82.92 )
36.9 86.96 ( 74.77 ) 96.46 ( 82.94 )

FAN-2209 201709 1-81


SELECTION DATA

Table 14. Outdoor Unit Capacity (JTOR260~300VAE(U,F,R)BS1) with Total Horsepower of Combined Indoor Unit (5)
Total Outdoor Unit Capacity: kW (×1000kcal/h)
RAS-26FSXNS
JTOR260VAE(U,F,R)BS1 RAS-28FSXNS
JTOR280VAE(U,F,R)BS1 RAS-30FSXNS
JTOR300VAE(U,F,R)BS1
Cooling Heating Cooling Heating Cooling Heating
37.0 86.98 ( 74.79 ) 96.48 ( 82.96 )
37.1 87.01 ( 74.82 ) 96.50 ( 82.97 )
37.2 87.04 ( 74.84 ) 96.52 ( 82.99 )
37.3 87.07 ( 74.87 ) 96.54 ( 83.01 )
37.4 87.10 ( 74.89 ) 96.56 ( 83.03 )
37.5 87.13 ( 74.91 ) 96.58 ( 83.05 )
37.6 87.15 ( 74.94 ) 96.60 ( 83.06 )
37.7 87.18 ( 74.96 ) 96.63 ( 83.08 )
37.8 87.21 ( 74.99 ) 96.65 ( 83.10 )
37.9 87.24 ( 75.01 ) 96.67 ( 83.12 )
38.0 _ _ 87.27 ( 75.04 ) 96.69 ( 83.14 )
38.1 87.30 ( 75.06 ) 96.71 ( 83.16 )
38.2 87.32 ( 75.08 ) 96.73 ( 83.17 )
38.3 87.35 ( 75.11 ) 96.75 ( 83.19 )
38.4 87.38 ( 75.13 ) 96.77 ( 83.21 )
38.5 87.41 ( 75.16 ) 96.79 ( 83.23 )
38.6 87.44 ( 75.18 ) 96.82 ( 83.25 )
38.7 87.47 ( 75.21 ) 96.84 ( 83.26 )
38.8 87.49 ( 75.23 ) 96.86 ( 83.28 )
38.9 87.52 ( 75.26 ) 96.88 ( 83.30 )
39.0 87.55 ( 75.28 ) 96.90 ( 83.32 )

1-82 FAN-2209 201709


SELECTION DATA

Table 15. Outdoor Unit Capacity (JTOR320~360VAE(U,F,R)BS1) with Total Horsepower of Combined Indoor Unit (1)
Total Outdoor Unit Capacity: kW (×1000kcal/h)
RAS-32FSXNS
JTOR320VAE(U,F,R)BS1 RAS-34FSXNS
JTOR340VAE(U,F,R)BS1 RAS-36FSXNS
JTOR360VAE(U,F,R)BS1
Cooling Heating Cooling Heating Cooling Heating
16.0 45.00 ( 38.69 ) 50.00 ( 42.99 )
16.1 45.28 ( 38.93 ) 50.31 ( 43.26 )
16.2 45.56 ( 39.18 ) 50.62 ( 43.53 )
16.3 45.84 ( 39.42 ) 50.94 ( 43.80 )
16.4 46.12 ( 39.66 ) 51.25 ( 44.07 )
_
16.5 46.41 ( 39.90 ) 51.56 ( 44.34 )
16.6 46.69 ( 40.14 ) 51.87 ( 44.60 )
16.7 46.97 ( 40.39 ) 52.19 ( 44.87 )
16.8 47.25 ( 40.63 ) 52.50 ( 45.14 )
16.9 47.53 ( 40.87 ) 52.81 ( 45.41 )
_
17.0 47.81 ( 41.11 ) 53.12 ( 45.68 ) 47.50 ( 40.84 ) 53.00 ( 45.57 )
17.1 48.09 ( 41.35 ) 53.44 ( 45.95 ) 47.78 ( 41.08 ) 53.31 ( 45.84 )
17.2 48.37 ( 41.60 ) 53.75 ( 46.22 ) 48.06 ( 41.32 ) 53.62 ( 46.11 )
17.3 48.66 ( 41.84 ) 54.06 ( 46.49 ) 48.34 ( 41.56 ) 53.94 ( 46.38 )
17.4 48.94 ( 42.08 ) 54.37 ( 46.75 ) 48.62 ( 41.80 ) 54.25 ( 46.64 )
17.5 49.22 ( 42.32 ) 54.69 ( 47.02 ) 48.90 ( 42.04 ) 54.56 ( 46.91 )
17.6 49.50 ( 42.56 ) 55.00 ( 47.29 ) 49.18 ( 42.28 ) 54.87 ( 47.18 )
17.7 49.78 ( 42.80 ) 55.31 ( 47.56 ) 49.46 ( 42.52 ) 55.18 ( 47.45 )
17.8 50.06 ( 43.05 ) 55.62 ( 47.83 ) 49.74 ( 42.76 ) 55.49 ( 47.72 )
17.9 50.34 ( 43.29 ) 55.94 ( 48.10 ) 50.01 ( 43.00 ) 55.81 ( 47.98 )
18.0 50.62 ( 43.53 ) 56.25 ( 48.37 ) 50.29 ( 43.25 ) 56.12 ( 48.25 ) 50.00 ( 42.99 ) 56.00 ( 48.15 )
18.1 50.91 ( 43.77 ) 56.56 ( 48.63 ) 50.57 ( 43.49 ) 56.43 ( 48.52 ) 50.28 ( 43.23 ) 56.31 ( 48.42 )
18.2 51.19 ( 44.01 ) 56.87 ( 48.90 ) 50.85 ( 43.73 ) 56.74 ( 48.79 ) 50.56 ( 43.47 ) 56.62 ( 48.69 )
18.3 51.47 ( 44.26 ) 57.19 ( 49.17 ) 51.13 ( 43.97 ) 57.05 ( 49.06 ) 50.83 ( 43.71 ) 56.93 ( 48.95 )
18.4 51.75 ( 44.50 ) 57.50 ( 49.44 ) 51.41 ( 44.21 ) 57.36 ( 49.32 ) 51.11 ( 43.95 ) 57.24 ( 49.22 )
18.5 52.03 ( 44.74 ) 57.81 ( 49.71 ) 51.69 ( 44.45 ) 57.68 ( 49.59 ) 51.39 ( 44.19 ) 57.56 ( 49.49 )
18.6 52.31 ( 44.98 ) 58.12 ( 49.98 ) 51.97 ( 44.69 ) 57.99 ( 49.86 ) 51.67 ( 44.43 ) 57.87 ( 49.76 )
18.7 52.59 ( 45.22 ) 58.44 ( 50.25 ) 52.25 ( 44.93 ) 58.30 ( 50.13 ) 51.94 ( 44.66 ) 58.18 ( 50.02 )
18.8 52.87 ( 45.46 ) 58.75 ( 50.52 ) 52.53 ( 45.17 ) 58.61 ( 50.40 ) 52.22 ( 44.90 ) 58.49 ( 50.29 )
18.9 53.16 ( 45.71 ) 59.06 ( 50.78 ) 52.81 ( 45.41 ) 58.92 ( 50.67 ) 52.50 ( 45.14 ) 58.80 ( 50.56 )
19.0 53.44 ( 45.95 ) 59.37 ( 51.05 ) 53.09 ( 45.65 ) 59.24 ( 50.93 ) 52.78 ( 45.38 ) 59.11 ( 50.83 )
19.1 53.72 ( 46.19 ) 59.69 ( 51.32 ) 53.37 ( 45.89 ) 59.55 ( 51.20 ) 53.06 ( 45.62 ) 59.42 ( 51.09 )
19.2 54.00 ( 46.43 ) 60.00 ( 51.59 ) 53.65 ( 46.13 ) 59.86 ( 51.47 ) 53.33 ( 45.86 ) 59.73 ( 51.36 )
19.3 54.28 ( 46.67 ) 60.31 ( 51.86 ) 53.93 ( 46.37 ) 60.17 ( 51.74 ) 53.61 ( 46.10 ) 60.04 ( 51.63 )
19.4 54.56 ( 46.92 ) 60.62 ( 52.13 ) 54.21 ( 46.61 ) 60.48 ( 52.01 ) 53.89 ( 46.34 ) 60.36 ( 51.90 )
19.5 54.84 ( 47.16 ) 60.94 ( 52.40 ) 54.49 ( 46.85 ) 60.79 ( 52.27 ) 54.17 ( 46.57 ) 60.67 ( 52.16 )
19.6 55.12 ( 47.40 ) 61.25 ( 52.67 ) 54.76 ( 47.09 ) 61.11 ( 52.54 ) 54.44 ( 46.81 ) 60.98 ( 52.43 )
19.7 55.41 ( 47.64 ) 61.56 ( 52.93 ) 55.04 ( 47.33 ) 61.42 ( 52.81 ) 54.72 ( 47.05 ) 61.29 ( 52.70 )
19.8 55.69 ( 47.88 ) 61.87 ( 53.20 ) 55.32 ( 47.57 ) 61.73 ( 53.08 ) 55.00 ( 47.29 ) 61.60 ( 52.97 )
19.9 55.97 ( 48.12 ) 62.19 ( 53.47 ) 55.60 ( 47.81 ) 62.04 ( 53.35 ) 55.28 ( 47.53 ) 61.91 ( 53.23 )
20.0 56.25 ( 48.37 ) 62.50 ( 53.74 ) 55.88 ( 48.05 ) 62.35 ( 53.61 ) 55.56 ( 47.77 ) 62.22 ( 53.50 )
20.1 56.53 ( 48.61 ) 62.81 ( 54.01 ) 56.16 ( 48.29 ) 62.66 ( 53.88 ) 55.83 ( 48.01 ) 62.53 ( 53.77 )
20.2 56.81 ( 48.85 ) 63.12 ( 54.28 ) 56.44 ( 48.53 ) 62.98 ( 54.15 ) 56.11 ( 48.25 ) 62.84 ( 54.04 )
20.3 57.09 ( 49.09 ) 63.44 ( 54.55 ) 56.72 ( 48.77 ) 63.29 ( 54.42 ) 56.39 ( 48.49 ) 63.16 ( 54.30 )
20.4 57.37 ( 49.33 ) 63.75 ( 54.82 ) 57.00 ( 49.01 ) 63.60 ( 54.69 ) 56.67 ( 48.72 ) 63.47 ( 54.57 )
20.5 57.66 ( 49.58 ) 64.06 ( 55.08 ) 57.28 ( 49.25 ) 63.91 ( 54.95 ) 56.94 ( 48.96 ) 63.78 ( 54.84 )
20.6 57.94 ( 49.82 ) 64.37 ( 55.35 ) 57.56 ( 49.49 ) 64.22 ( 55.22 ) 57.22 ( 49.20 ) 64.09 ( 55.11 )
20.7 58.22 ( 50.06 ) 64.69 ( 55.62 ) 57.84 ( 49.73 ) 64.54 ( 55.49 ) 57.50 ( 49.44 ) 64.40 ( 55.37 )
20.8 58.50 ( 50.30 ) 65.00 ( 55.89 ) 58.12 ( 49.97 ) 64.85 ( 55.76 ) 57.78 ( 49.68 ) 64.71 ( 55.64 )
20.9 58.78 ( 50.54 ) 65.31 ( 56.16 ) 58.40 ( 50.21 ) 65.16 ( 56.03 ) 58.06 ( 49.92 ) 65.02 ( 55.91 )
21.0 59.06 ( 50.78 ) 65.63 ( 56.43 ) 58.68 ( 50.45 ) 65.47 ( 56.29 ) 58.33 ( 50.16 ) 65.33 ( 56.18 )
21.1 59.34 ( 51.03 ) 65.94 ( 56.70 ) 58.96 ( 50.69 ) 65.78 ( 56.56 ) 58.61 ( 50.40 ) 65.64 ( 56.44 )
21.2 59.63 ( 51.27 ) 66.25 ( 56.96 ) 59.24 ( 50.93 ) 66.09 ( 56.83 ) 58.89 ( 50.64 ) 65.96 ( 56.71 )
21.3 59.91 ( 51.51 ) 66.56 ( 57.23 ) 59.51 ( 51.17 ) 66.41 ( 57.10 ) 59.17 ( 50.87 ) 66.27 ( 56.98 )
21.4 60.19 ( 51.75 ) 66.88 ( 57.50 ) 59.79 ( 51.41 ) 66.72 ( 57.37 ) 59.44 ( 51.11 ) 66.58 ( 57.25 )
21.5 60.47 ( 51.99 ) 67.19 ( 57.77 ) 60.07 ( 51.65 ) 67.03 ( 57.63 ) 59.72 ( 51.35 ) 66.89 ( 57.51 )
21.6 60.75 ( 52.24 ) 67.50 ( 58.04 ) 60.35 ( 51.89 ) 67.34 ( 57.90 ) 60.00 ( 51.59 ) 67.20 ( 57.78 )
21.7 61.03 ( 52.48 ) 67.81 ( 58.31 ) 60.63 ( 52.13 ) 67.65 ( 58.17 ) 60.28 ( 51.83 ) 67.51 ( 58.05 )
21.8 61.31 ( 52.72 ) 68.13 ( 58.58 ) 60.91 ( 52.37 ) 67.96 ( 58.44 ) 60.56 ( 52.07 ) 67.82 ( 58.32 )
21.9 61.59 ( 52.96 ) 68.44 ( 58.85 ) 61.19 ( 52.61 ) 68.28 ( 58.71 ) 60.83 ( 52.31 ) 68.13 ( 58.58 )

FAN-2209 201709 1-83


SELECTION DATA

Table 16. Outdoor Unit Capacity (JTOR320~360VAE(U,F,R)BS1) with Total Horsepower of Combined Indoor Unit (2)
Total Outdoor Unit Capacity: kW (×1000kcal/h)
RAS-32FSXNS
JTOR320VAE(U,F,R)BS1 RAS-34FSXNS
JTOR340VAE(U,F,R)BS1 RAS-36FSXNS
JTOR360VAE(U,F,R)BS1
Cooling Heating Cooling Heating Cooling Heating
22.0 61.88 ( 53.20 ) 68.75 ( 59.11 ) 61.47 ( 52.86 ) 68.59 ( 58.98 ) 61.11 ( 52.55 ) 68.44 ( 58.85 )
22.1 62.16 ( 53.44 ) 69.06 ( 59.38 ) 61.75 ( 53.10 ) 68.90 ( 59.24 ) 61.39 ( 52.78 ) 68.76 ( 59.12 )
22.2 62.44 ( 53.69 ) 69.38 ( 59.65 ) 62.03 ( 53.34 ) 69.21 ( 59.51 ) 61.67 ( 53.02 ) 69.07 ( 59.39 )
22.3 62.72 ( 53.93 ) 69.69 ( 59.92 ) 62.31 ( 53.58 ) 69.52 ( 59.78 ) 61.94 ( 53.26 ) 69.38 ( 59.65 )
22.4 63.00 ( 54.17 ) 70.00 ( 60.19 ) 62.59 ( 53.82 ) 69.84 ( 60.05 ) 62.22 ( 53.50 ) 69.69 ( 59.92 )
22.5 63.28 ( 54.41 ) 70.31 ( 60.46 ) 62.87 ( 54.06 ) 70.15 ( 60.32 ) 62.50 ( 53.74 ) 70.00 ( 60.19 )
22.6 63.56 ( 54.65 ) 70.63 ( 60.73 ) 63.15 ( 54.30 ) 70.46 ( 60.58 ) 62.78 ( 53.98 ) 70.31 ( 60.46 )
22.7 63.84 ( 54.90 ) 70.94 ( 61.00 ) 63.43 ( 54.54 ) 70.77 ( 60.85 ) 63.06 ( 54.22 ) 70.62 ( 60.72 )
22.8 64.13 ( 55.14 ) 71.25 ( 61.26 ) 63.71 ( 54.78 ) 71.08 ( 61.12 ) 63.33 ( 54.46 ) 70.93 ( 60.99 )
22.9 64.41 ( 55.38 ) 71.56 ( 61.53 ) 63.99 ( 55.02 ) 71.39 ( 61.39 ) 63.61 ( 54.70 ) 71.24 ( 61.26 )
23.0 64.69 ( 55.62 ) 71.88 ( 61.80 ) 64.26 ( 55.26 ) 71.71 ( 61.66 ) 63.89 ( 54.93 ) 71.56 ( 61.53 )
23.1 64.97 ( 55.86 ) 72.19 ( 62.07 ) 64.54 ( 55.50 ) 72.02 ( 61.92 ) 64.17 ( 55.17 ) 71.87 ( 61.79 )
23.2 65.25 ( 56.10 ) 72.50 ( 62.34 ) 64.82 ( 55.74 ) 72.33 ( 62.19 ) 64.44 ( 55.41 ) 72.18 ( 62.06 )
23.3 65.53 ( 56.35 ) 72.81 ( 62.61 ) 65.10 ( 55.98 ) 72.64 ( 62.46 ) 64.72 ( 55.65 ) 72.49 ( 62.33 )
23.4 65.81 ( 56.59 ) 73.12 ( 62.88 ) 65.38 ( 56.22 ) 72.95 ( 62.73 ) 65.00 ( 55.89 ) 72.80 ( 62.60 )
23.5 66.09 ( 56.83 ) 73.44 ( 63.14 ) 65.66 ( 56.46 ) 73.26 ( 63.00 ) 65.28 ( 56.13 ) 73.11 ( 62.86 )
23.6 66.37 ( 57.07 ) 73.75 ( 63.41 ) 65.94 ( 56.70 ) 73.58 ( 63.26 ) 65.56 ( 56.37 ) 73.42 ( 63.13 )
23.7 66.66 ( 57.31 ) 74.06 ( 63.68 ) 66.22 ( 56.94 ) 73.89 ( 63.53 ) 65.83 ( 56.61 ) 73.73 ( 63.40 )
23.8 66.94 ( 57.56 ) 74.37 ( 63.95 ) 66.50 ( 57.18 ) 74.20 ( 63.80 ) 66.11 ( 56.85 ) 74.04 ( 63.67 )
23.9 67.22 ( 57.80 ) 74.69 ( 64.22 ) 66.78 ( 57.42 ) 74.51 ( 64.07 ) 66.39 ( 57.08 ) 74.36 ( 63.93 )
24.0 67.50 ( 58.04 ) 75.00 ( 64.49 ) 67.06 ( 57.66 ) 74.82 ( 64.34 ) 66.67 ( 57.32 ) 74.67 ( 64.20 )
24.1 67.78 ( 58.28 ) 75.31 ( 64.76 ) 67.34 ( 57.90 ) 75.14 ( 64.60 ) 66.94 ( 57.56 ) 74.98 ( 64.47 )
24.2 68.06 ( 58.52 ) 75.62 ( 65.03 ) 67.62 ( 58.14 ) 75.45 ( 64.87 ) 67.22 ( 57.80 ) 75.29 ( 64.74 )
24.3 68.34 ( 58.77 ) 75.94 ( 65.29 ) 67.90 ( 58.38 ) 75.76 ( 65.14 ) 67.50 ( 58.04 ) 75.60 ( 65.00 )
24.4 68.62 ( 59.01 ) 76.25 ( 65.56 ) 68.18 ( 58.62 ) 76.07 ( 65.41 ) 67.78 ( 58.28 ) 75.91 ( 65.27 )
24.5 68.91 ( 59.25 ) 76.56 ( 65.83 ) 68.46 ( 58.86 ) 76.38 ( 65.68 ) 68.06 ( 58.52 ) 76.22 ( 65.54 )
24.6 69.19 ( 59.49 ) 76.87 ( 66.10 ) 68.74 ( 59.10 ) 76.69 ( 65.95 ) 68.33 ( 58.76 ) 76.53 ( 65.81 )
24.7 69.47 ( 59.73 ) 77.19 ( 66.37 ) 69.01 ( 59.34 ) 77.01 ( 66.21 ) 68.61 ( 58.99 ) 76.84 ( 66.07 )
24.8 69.75 ( 59.97 ) 77.50 ( 66.64 ) 69.29 ( 59.58 ) 77.32 ( 66.48 ) 68.89 ( 59.23 ) 77.16 ( 66.34 )
24.9 70.03 ( 60.22 ) 77.81 ( 66.91 ) 69.57 ( 59.82 ) 77.63 ( 66.75 ) 69.17 ( 59.47 ) 77.47 ( 66.61 )
25.0 70.31 ( 60.46 ) 78.12 ( 67.18 ) 69.85 ( 60.06 ) 77.94 ( 67.02 ) 69.44 ( 59.71 ) 77.78 ( 66.88 )
25.1 70.59 ( 60.70 ) 78.44 ( 67.44 ) 70.13 ( 60.30 ) 78.25 ( 67.29 ) 69.72 ( 59.95 ) 78.09 ( 67.14 )
25.2 70.87 ( 60.94 ) 78.75 ( 67.71 ) 70.41 ( 60.54 ) 78.56 ( 67.55 ) 70.00 ( 60.19 ) 78.40 ( 67.41 )
25.3 71.16 ( 61.18 ) 79.06 ( 67.98 ) 70.69 ( 60.78 ) 78.88 ( 67.82 ) 70.28 ( 60.43 ) 78.71 ( 67.68 )
25.4 71.44 ( 61.43 ) 79.37 ( 68.25 ) 70.97 ( 61.02 ) 79.19 ( 68.09 ) 70.56 ( 60.67 ) 79.02 ( 67.95 )
25.5 71.72 ( 61.67 ) 79.69 ( 68.52 ) 71.25 ( 61.26 ) 79.50 ( 68.36 ) 70.83 ( 60.91 ) 79.33 ( 68.21 )
25.6 72.00 ( 61.91 ) 80.00 ( 68.79 ) 71.53 ( 61.50 ) 79.81 ( 68.63 ) 71.11 ( 61.14 ) 79.64 ( 68.48 )
25.7 72.28 ( 62.15 ) 80.31 ( 69.06 ) 71.81 ( 61.74 ) 80.12 ( 68.89 ) 71.39 ( 61.38 ) 79.96 ( 68.75 )
25.8 72.56 ( 62.39 ) 80.62 ( 69.33 ) 72.09 ( 61.98 ) 80.44 ( 69.16 ) 71.67 ( 61.62 ) 80.27 ( 69.02 )
25.9 72.84 ( 62.63 ) 80.94 ( 69.59 ) 72.37 ( 62.22 ) 80.75 ( 69.43 ) 71.94 ( 61.86 ) 80.58 ( 69.28 )
26.0 73.12 ( 62.88 ) 81.25 ( 69.86 ) 72.65 ( 62.47 ) 81.06 ( 69.70 ) 72.22 ( 62.10 ) 80.89 ( 69.55 )
26.1 73.41 ( 63.12 ) 81.56 ( 70.13 ) 72.93 ( 62.71 ) 81.37 ( 69.97 ) 72.50 ( 62.34 ) 81.20 ( 69.82 )
26.2 73.69 ( 63.36 ) 81.87 ( 70.40 ) 73.21 ( 62.95 ) 81.68 ( 70.23 ) 72.78 ( 62.58 ) 81.51 ( 70.09 )
26.3 73.97 ( 63.60 ) 82.19 ( 70.67 ) 73.49 ( 63.19 ) 81.99 ( 70.50 ) 73.06 ( 62.82 ) 81.82 ( 70.35 )
26.4 74.25 ( 63.84 ) 82.50 ( 70.94 ) 73.76 ( 63.43 ) 82.31 ( 70.77 ) 73.33 ( 63.06 ) 82.13 ( 70.62 )
26.5 74.53 ( 64.09 ) 82.81 ( 71.21 ) 74.04 ( 63.67 ) 82.62 ( 71.04 ) 73.61 ( 63.29 ) 82.44 ( 70.89 )
26.6 74.81 ( 64.33 ) 83.12 ( 71.47 ) 74.32 ( 63.91 ) 82.93 ( 71.31 ) 73.89 ( 63.53 ) 82.76 ( 71.16 )
26.7 75.09 ( 64.57 ) 83.44 ( 71.74 ) 74.60 ( 64.15 ) 83.24 ( 71.57 ) 74.17 ( 63.77 ) 83.07 ( 71.42 )
26.8 75.37 ( 64.81 ) 83.75 ( 72.01 ) 74.88 ( 64.39 ) 83.55 ( 71.84 ) 74.44 ( 64.01 ) 83.38 ( 71.69 )
26.9 75.66 ( 65.05 ) 84.06 ( 72.28 ) 75.16 ( 64.63 ) 83.86 ( 72.11 ) 74.72 ( 64.25 ) 83.69 ( 71.96 )
27.0 75.94 ( 65.29 ) 84.37 ( 72.55 ) 75.44 ( 64.87 ) 84.18 ( 72.38 ) 75.00 ( 64.49 ) 84.00 ( 72.23 )
27.1 76.22 ( 65.54 ) 84.69 ( 72.82 ) 75.72 ( 65.11 ) 84.49 ( 72.65 ) 75.28 ( 64.73 ) 84.31 ( 72.49 )
27.2 76.50 ( 65.78 ) 85.00 ( 73.09 ) 76.00 ( 65.35 ) 84.80 ( 72.91 ) 75.56 ( 64.97 ) 84.62 ( 72.76 )
27.3 76.78 ( 66.02 ) 85.31 ( 73.36 ) 76.28 ( 65.59 ) 85.11 ( 73.18 ) 75.83 ( 65.20 ) 84.93 ( 73.03 )
27.4 77.06 ( 66.26 ) 85.62 ( 73.62 ) 76.56 ( 65.83 ) 85.42 ( 73.45 ) 76.11 ( 65.44 ) 85.24 ( 73.30 )
27.5 77.34 ( 66.50 ) 85.94 ( 73.89 ) 76.84 ( 66.07 ) 85.74 ( 73.72 ) 76.39 ( 65.68 ) 85.56 ( 73.56 )
27.6 77.62 ( 66.75 ) 86.25 ( 74.16 ) 77.12 ( 66.31 ) 86.05 ( 73.99 ) 76.67 ( 65.92 ) 85.87 ( 73.83 )
27.7 77.91 ( 66.99 ) 86.56 ( 74.43 ) 77.40 ( 66.55 ) 86.36 ( 74.26 ) 76.94 ( 66.16 ) 86.18 ( 74.10 )
27.8 78.19 ( 67.23 ) 86.88 ( 74.70 ) 77.68 ( 66.79 ) 86.67 ( 74.52 ) 77.22 ( 66.40 ) 86.49 ( 74.37 )
27.9 78.47 ( 67.47 ) 87.19 ( 74.97 ) 77.96 ( 67.03 ) 86.98 ( 74.79 ) 77.50 ( 66.64 ) 86.80 ( 74.63 )

1-84 FAN-2209 201709


SELECTION DATA

Table 17. Outdoor Unit Capacity (JTOR320~360VAE(U,F,R)BS1) with Total Horsepower of Combined Indoor Unit (3)
Total Outdoor Unit Capacity: kW (×1000kcal/h)
RAS-32FSXNS
JTOR320VAE(U,F,R)BS1 RAS-34FSXNS
JTOR340VAE(U,F,R)BS1 RAS-36FSXNS
JTOR360VAE(U,F,R)BS1
Cooling Heating Cooling Heating Cooling Heating
28.0 78.75 ( 67.71 ) 87.50 ( 75.24 ) 78.24 ( 67.27 ) 87.29 ( 75.06 ) 77.78 ( 66.88 ) 87.11 ( 74.90 )
28.1 79.03 ( 67.95 ) 87.81 ( 75.51 ) 78.51 ( 67.51 ) 87.61 ( 75.33 ) 78.06 ( 67.12 ) 87.42 ( 75.17 )
28.2 79.31 ( 68.20 ) 88.13 ( 75.77 ) 78.79 ( 67.75 ) 87.92 ( 75.60 ) 78.33 ( 67.35 ) 87.73 ( 75.44 )
28.3 79.59 ( 68.44 ) 88.44 ( 76.04 ) 79.07 ( 67.99 ) 88.23 ( 75.86 ) 78.61 ( 67.59 ) 88.04 ( 75.70 )
28.4 79.88 ( 68.68 ) 88.75 ( 76.31 ) 79.35 ( 68.23 ) 88.54 ( 76.13 ) 78.89 ( 67.83 ) 88.36 ( 75.97 )
28.5 80.16 ( 68.92 ) 89.06 ( 76.58 ) 79.63 ( 68.47 ) 88.85 ( 76.40 ) 79.17 ( 68.07 ) 88.67 ( 76.24 )
28.6 80.44 ( 69.16 ) 89.38 ( 76.85 ) 79.91 ( 68.71 ) 89.16 ( 76.67 ) 79.44 ( 68.31 ) 88.98 ( 76.51 )
28.7 80.72 ( 69.41 ) 89.69 ( 77.12 ) 80.19 ( 68.95 ) 89.48 ( 76.94 ) 79.72 ( 68.55 ) 89.29 ( 76.77 )
28.8 81.00 ( 69.65 ) 90.00 ( 77.39 ) 80.47 ( 69.19 ) 89.79 ( 77.20 ) 80.00 ( 68.79 ) 89.60 ( 77.04 )
28.9 81.28 ( 69.89 ) 90.31 ( 77.65 ) 80.75 ( 69.43 ) 90.10 ( 77.47 ) 80.28 ( 69.03 ) 89.91 ( 77.31 )
29.0 81.56 ( 70.13 ) 90.63 ( 77.92 ) 81.03 ( 69.67 ) 90.41 ( 77.74 ) 80.56 ( 69.27 ) 90.22 ( 77.58 )
29.1 81.84 ( 70.37 ) 90.94 ( 78.19 ) 81.31 ( 69.91 ) 90.72 ( 78.01 ) 80.83 ( 69.50 ) 90.53 ( 77.84 )
29.2 82.13 ( 70.61 ) 91.25 ( 78.46 ) 81.59 ( 70.15 ) 91.04 ( 78.28 ) 81.11 ( 69.74 ) 90.84 ( 78.11 )
29.3 82.41 ( 70.86 ) 91.56 ( 78.73 ) 81.87 ( 70.39 ) 91.35 ( 78.54 ) 81.39 ( 69.98 ) 91.16 ( 78.38 )
29.4 82.69 ( 71.10 ) 91.88 ( 79.00 ) 82.15 ( 70.63 ) 91.66 ( 78.81 ) 81.67 ( 70.22 ) 91.47 ( 78.65 )
29.5 82.97 ( 71.34 ) 92.19 ( 79.27 ) 82.43 ( 70.87 ) 91.97 ( 79.08 ) 81.94 ( 70.46 ) 91.78 ( 78.91 )
29.6 83.25 ( 71.58 ) 92.50 ( 79.54 ) 82.71 ( 71.11 ) 92.28 ( 79.35 ) 82.22 ( 70.70 ) 92.09 ( 79.18 )
29.7 83.53 ( 71.82 ) 92.81 ( 79.80 ) 82.99 ( 71.35 ) 92.59 ( 79.62 ) 82.50 ( 70.94 ) 92.40 ( 79.45 )
29.8 83.81 ( 72.07 ) 93.13 ( 80.07 ) 83.26 ( 71.59 ) 92.91 ( 79.88 ) 82.78 ( 71.18 ) 92.71 ( 79.72 )
29.9 84.09 ( 72.31 ) 93.44 ( 80.34 ) 83.54 ( 71.84 ) 93.22 ( 80.15 ) 83.06 ( 71.41 ) 93.02 ( 79.98 )
30.0 84.38 ( 72.55 ) 93.75 ( 80.61 ) 83.82 ( 72.08 ) 93.53 ( 80.42 ) 83.33 ( 71.65 ) 93.33 ( 80.25 )
30.1 84.66 ( 72.79 ) 94.06 ( 80.88 ) 84.10 ( 72.32 ) 93.84 ( 80.69 ) 83.61 ( 71.89 ) 93.64 ( 80.52 )
30.2 84.94 ( 73.03 ) 94.38 ( 81.15 ) 84.38 ( 72.56 ) 94.15 ( 80.96 ) 83.89 ( 72.13 ) 93.96 ( 80.79 )
30.3 85.22 ( 73.27 ) 94.69 ( 81.42 ) 84.66 ( 72.80 ) 94.46 ( 81.23 ) 84.17 ( 72.37 ) 94.27 ( 81.05 )
30.4 85.50 ( 73.52 ) 95.00 ( 81.69 ) 84.94 ( 73.04 ) 94.78 ( 81.49 ) 84.44 ( 72.61 ) 94.58 ( 81.32 )
30.5 85.78 ( 73.76 ) 95.31 ( 81.95 ) 85.22 ( 73.28 ) 95.09 ( 81.76 ) 84.72 ( 72.85 ) 94.89 ( 81.59 )
30.6 86.06 ( 74.00 ) 95.63 ( 82.22 ) 85.50 ( 73.52 ) 95.40 ( 82.03 ) 85.00 ( 73.09 ) 95.20 ( 81.86 )
30.7 86.34 ( 74.24 ) 95.94 ( 82.49 ) 85.78 ( 73.76 ) 95.71 ( 82.30 ) 85.28 ( 73.33 ) 95.51 ( 82.12 )
30.8 86.63 ( 74.48 ) 96.25 ( 82.76 ) 86.06 ( 74.00 ) 96.02 ( 82.57 ) 85.56 ( 73.56 ) 95.82 ( 82.39 )
30.9 86.91 ( 74.73 ) 96.56 ( 83.03 ) 86.34 ( 74.24 ) 96.34 ( 82.83 ) 85.83 ( 73.80 ) 96.13 ( 82.66 )
31.0 87.19 ( 74.97 ) 96.88 ( 83.30 ) 86.62 ( 74.48 ) 96.65 ( 83.10 ) 86.11 ( 74.04 ) 96.44 ( 82.93 )
31.1 87.47 ( 75.21 ) 97.19 ( 83.57 ) 86.90 ( 74.72 ) 96.96 ( 83.37 ) 86.39 ( 74.28 ) 96.76 ( 83.19 )
31.2 87.75 ( 75.45 ) 97.50 ( 83.83 ) 87.18 ( 74.96 ) 97.27 ( 83.64 ) 86.67 ( 74.52 ) 97.07 ( 83.46 )
31.3 88.03 ( 75.69 ) 97.81 ( 84.10 ) 87.46 ( 75.20 ) 97.58 ( 83.91 ) 86.94 ( 74.76 ) 97.38 ( 83.73 )
31.4 88.31 ( 75.94 ) 98.13 ( 84.37 ) 87.74 ( 75.44 ) 97.89 ( 84.17 ) 87.22 ( 75.00 ) 97.69 ( 84.00 )
31.5 88.59 ( 76.18 ) 98.44 ( 84.64 ) 88.01 ( 75.68 ) 98.21 ( 84.44 ) 87.50 ( 75.24 ) 98.00 ( 84.26 )
31.6 88.88 ( 76.42 ) 98.75 ( 84.91 ) 88.29 ( 75.92 ) 98.52 ( 84.71 ) 87.78 ( 75.48 ) 98.31 ( 84.53 )
31.7 89.16 ( 76.66 ) 99.06 ( 85.18 ) 88.57 ( 76.16 ) 98.83 ( 84.98 ) 88.06 ( 75.71 ) 98.62 ( 84.80 )
31.8 89.44 ( 76.90 ) 99.38 ( 85.45 ) 88.85 ( 76.40 ) 99.14 ( 85.25 ) 88.33 ( 75.95 ) 98.93 ( 85.07 )
31.9 89.72 ( 77.14 ) 99.69 ( 85.72 ) 89.13 ( 76.64 ) 99.45 ( 85.51 ) 88.61 ( 76.19 ) 99.24 ( 85.33 )
32.0 90.00 ( 77.39 ) 100.00 ( 85.98 ) 89.41 ( 76.88 ) 99.76 ( 85.78 ) 88.89 ( 76.43 ) 99.56 ( 85.60 )
32.1 90.03 ( 77.41 ) 100.02 ( 86.00 ) 89.69 ( 77.12 ) 100.08 ( 86.05 ) 89.17 ( 76.67 ) 99.87 ( 85.87 )
32.2 90.06 ( 77.43 ) 100.04 ( 86.02 ) 89.97 ( 77.36 ) 100.39 ( 86.32 ) 89.44 ( 76.91 ) 100.18 ( 86.14 )
32.3 90.08 ( 77.46 ) 100.06 ( 86.04 ) 90.25 ( 77.60 ) 100.70 ( 86.59 ) 89.72 ( 77.15 ) 100.49 ( 86.40 )
32.4 90.11 ( 77.48 ) 100.08 ( 86.06 ) 90.53 ( 77.84 ) 101.01 ( 86.85 ) 90.00 ( 77.39 ) 100.80 ( 86.67 )
32.5 90.14 ( 77.51 ) 100.10 ( 86.07 ) 90.81 ( 78.08 ) 101.32 ( 87.12 ) 90.28 ( 77.62 ) 101.11 ( 86.94 )
32.6 90.17 ( 77.53 ) 100.13 ( 86.09 ) 91.09 ( 78.32 ) 101.64 ( 87.39 ) 90.56 ( 77.86 ) 101.42 ( 87.21 )
32.7 90.20 ( 77.56 ) 100.15 ( 86.11 ) 91.37 ( 78.56 ) 101.95 ( 87.66 ) 90.83 ( 78.10 ) 101.73 ( 87.47 )
32.8 90.23 ( 77.58 ) 100.17 ( 86.13 ) 91.65 ( 78.80 ) 102.26 ( 87.93 ) 91.11 ( 78.34 ) 102.04 ( 87.74 )
32.9 90.25 ( 77.60 ) 100.19 ( 86.15 ) 91.93 ( 79.04 ) 102.57 ( 88.19 ) 91.39 ( 78.58 ) 102.36 ( 88.01 )
33.0 90.28 ( 77.63 ) 100.21 ( 86.16 ) 92.21 ( 79.28 ) 102.88 ( 88.46 ) 91.67 ( 78.82 ) 102.67 ( 88.28 )
33.1 90.31 ( 77.65 ) 100.23 ( 86.18 ) 92.49 ( 79.52 ) 103.19 ( 88.73 ) 91.94 ( 79.06 ) 102.98 ( 88.54 )
33.2 90.34 ( 77.68 ) 100.25 ( 86.20 ) 92.76 ( 79.76 ) 103.51 ( 89.00 ) 92.22 ( 79.30 ) 103.29 ( 88.81 )
33.3 90.37 ( 77.70 ) 100.27 ( 86.22 ) 93.04 ( 80.00 ) 103.82 ( 89.27 ) 92.50 ( 79.54 ) 103.60 ( 89.08 )
33.4 90.39 ( 77.72 ) 100.29 ( 86.24 ) 93.32 ( 80.24 ) 104.13 ( 89.54 ) 92.78 ( 79.77 ) 103.91 ( 89.35 )
33.5 90.42 ( 77.75 ) 100.31 ( 86.25 ) 93.60 ( 80.48 ) 104.44 ( 89.80 ) 93.06 ( 80.01 ) 104.22 ( 89.61 )
33.6 90.45 ( 77.77 ) 100.33 ( 86.27 ) 93.88 ( 80.72 ) 104.75 ( 90.07 ) 93.33 ( 80.25 ) 104.53 ( 89.88 )
33.7 90.48 ( 77.80 ) 100.35 ( 86.29 ) 94.16 ( 80.96 ) 105.06 ( 90.34 ) 93.61 ( 80.49 ) 104.84 ( 90.15 )
33.8 90.51 ( 77.82 ) 100.38 ( 86.31 ) 94.44 ( 81.20 ) 105.38 ( 90.61 ) 93.89 ( 80.73 ) 105.16 ( 90.42 )
33.9 90.53 ( 77.85 ) 100.40 ( 86.32 ) 94.72 ( 81.45 ) 105.69 ( 90.88 ) 94.17 ( 80.97 ) 105.47 ( 90.69 )

FAN-2209 201709 1-85


SELECTION DATA

Table 18. Outdoor Unit Capacity (JTOR320~360VAE(U,F,R)BS1) with Total Horsepower of Combined Indoor Unit (4)
Total Outdoor Unit Capacity: kW (×1000kcal/h)
RAS-32FSXNS
JTOR320VAE(U,F,R)BS1 RAS-34FSXNS
JTOR340VAE(U,F,R)BS1 RAS-36FSXNS
JTOR360VAE(U,F,R)BS1
Cooling Heating Cooling Heating Cooling Heating
34.0 90.56 ( 77.87 ) 100.42 ( 86.34 ) 95.00 ( 81.69 ) 106.00 ( 91.14 ) 94.44 ( 81.21 ) 105.78 ( 90.95 )
34.1 90.59 ( 77.89 ) 100.44 ( 86.36 ) 95.28 ( 81.93 ) 106.31 ( 91.41 ) 94.72 ( 81.45 ) 106.09 ( 91.22 )
34.2 90.62 ( 77.92 ) 100.46 ( 86.38 ) 95.56 ( 82.17 ) 106.62 ( 91.68 ) 95.00 ( 81.69 ) 106.40 ( 91.49 )
34.3 90.65 ( 77.94 ) 100.48 ( 86.40 ) 95.84 ( 82.41 ) 106.94 ( 91.95 ) 95.28 ( 81.92 ) 106.71 ( 91.76 )
34.4 90.68 ( 77.97 ) 100.50 ( 86.41 ) 96.12 ( 82.65 ) 107.25 ( 92.22 ) 95.56 ( 82.16 ) 107.02 ( 92.02 )
34.5 90.70 ( 77.99 ) 100.52 ( 86.43 ) 96.40 ( 82.89 ) 107.56 ( 92.48 ) 95.83 ( 82.40 ) 107.33 ( 92.29 )
34.6 90.73 ( 78.01 ) 100.54 ( 86.45 ) 96.68 ( 83.13 ) 107.87 ( 92.75 ) 96.11 ( 82.64 ) 107.64 ( 92.56 )
34.7 90.76 ( 78.04 ) 100.56 ( 86.47 ) 96.96 ( 83.37 ) 108.18 ( 93.02 ) 96.39 ( 82.88 ) 107.96 ( 92.83 )
34.8 90.79 ( 78.06 ) 100.58 ( 86.49 ) 97.24 ( 83.61 ) 108.49 ( 93.29 ) 96.67 ( 83.12 ) 108.27 ( 93.09 )
34.9 90.82 ( 78.09 ) 100.60 ( 86.50 ) 97.51 ( 83.85 ) 108.81 ( 93.56 ) 96.94 ( 83.36 ) 108.58 ( 93.36 )
35.0 90.84 ( 78.11 ) 100.63 ( 86.52 ) 97.79 ( 84.09 ) 109.12 ( 93.82 ) 97.22 ( 83.60 ) 108.89 ( 93.63 )
35.1 90.87 ( 78.14 ) 100.65 ( 86.54 ) 97.87 ( 84.16 ) 109.19 ( 93.89 ) 97.50 ( 83.83 ) 109.20 ( 93.90 )
35.2 90.90 ( 78.16 ) 100.67 ( 86.56 ) 97.91 ( 84.18 ) 109.20 ( 93.90 ) 97.78 ( 84.07 ) 109.51 ( 94.16 )
35.3 90.93 ( 78.18 ) 100.69 ( 86.58 ) 97.94 ( 84.21 ) 109.21 ( 93.91 ) 98.06 ( 84.31 ) 109.82 ( 94.43 )
35.4 90.96 ( 78.21 ) 100.71 ( 86.59 ) 97.97 ( 84.24 ) 109.22 ( 93.92 ) 98.33 ( 84.55 ) 110.13 ( 94.70 )
35.5 90.98 ( 78.23 ) 100.73 ( 86.61 ) 98.00 ( 84.26 ) 109.24 ( 93.93 ) 98.61 ( 84.79 ) 110.44 ( 94.97 )
35.6 91.01 ( 78.26 ) 100.75 ( 86.63 ) 98.03 ( 84.29 ) 109.25 ( 93.94 ) 98.89 ( 85.03 ) 110.76 ( 95.23 )
35.7 91.04 ( 78.28 ) 100.77 ( 86.65 ) 98.06 ( 84.32 ) 109.26 ( 93.95 ) 99.17 ( 85.27 ) 111.07 ( 95.50 )
35.8 91.07 ( 78.31 ) 100.79 ( 86.67 ) 98.09 ( 84.34 ) 109.27 ( 93.96 ) 99.44 ( 85.51 ) 111.38 ( 95.77 )
35.9 91.10 ( 78.33 ) 100.81 ( 86.68 ) 98.12 ( 84.37 ) 109.28 ( 93.97 ) 99.72 ( 85.75 ) 111.69 ( 96.04 )
36.0 91.13 ( 78.35 ) 100.83 ( 86.70 ) 98.15 ( 84.40 ) 109.29 ( 93.98 ) 100.00 ( 85.98 ) 112.00 ( 96.30 )
36.1 91.15 ( 78.38 ) 100.85 ( 86.72 ) 98.19 ( 84.42 ) 109.30 ( 93.99 ) 100.28 ( 86.22 ) 112.31 ( 96.57 )
36.2 91.18 ( 78.40 ) 100.88 ( 86.74 ) 98.22 ( 84.45 ) 109.32 ( 94.00 ) 100.56 ( 86.46 ) 112.62 ( 96.84 )
36.3 91.21 ( 78.43 ) 100.90 ( 86.75 ) 98.25 ( 84.48 ) 109.33 ( 94.00 ) 100.83 ( 86.70 ) 112.93 ( 97.11 )
36.4 91.24 ( 78.45 ) 100.92 ( 86.77 ) 98.28 ( 84.50 ) 109.34 ( 94.01 ) 101.11 ( 86.94 ) 113.24 ( 97.37 )
36.5 91.27 ( 78.47 ) 100.94 ( 86.79 ) 98.31 ( 84.53 ) 109.35 ( 94.02 ) 101.39 ( 87.18 ) 113.56 ( 97.64 )
36.6 91.29 ( 78.50 ) 100.96 ( 86.81 ) 98.34 ( 84.56 ) 109.36 ( 94.03 ) 101.67 ( 87.42 ) 113.87 ( 97.91 )
36.7 91.32 ( 78.52 ) 100.98 ( 86.83 ) 98.37 ( 84.58 ) 109.37 ( 94.04 ) 101.94 ( 87.66 ) 114.18 ( 98.18 )
36.8 91.35 ( 78.55 ) 101.00 ( 86.84 ) 98.40 ( 84.61 ) 109.39 ( 94.05 ) 102.22 ( 87.90 ) 114.49 ( 98.44 )
36.9 91.38 ( 78.57 ) 101.02 ( 86.86 ) 98.43 ( 84.64 ) 109.40 ( 94.06 ) 102.50 ( 88.13 ) 114.80 ( 98.71 )
37.0 91.41 ( 78.60 ) 101.04 ( 86.88 ) 98.46 ( 84.66 ) 109.41 ( 94.07 ) 102.78 ( 88.37 ) 115.11 ( 98.98 )
37.1 91.43 ( 78.62 ) 101.06 ( 86.90 ) 98.50 ( 84.69 ) 109.42 ( 94.08 ) 103.01 ( 88.57 ) 115.36 ( 99.19 )
37.2 91.46 ( 78.64 ) 101.08 ( 86.92 ) 98.53 ( 84.72 ) 109.43 ( 94.09 ) 103.04 ( 88.60 ) 115.37 ( 99.20 )
37.3 91.49 ( 78.67 ) 101.10 ( 86.93 ) 98.56 ( 84.74 ) 109.44 ( 94.10 ) 103.07 ( 88.62 ) 115.39 ( 99.21 )
37.4 91.52 ( 78.69 ) 101.13 ( 86.95 ) 98.59 ( 84.77 ) 109.45 ( 94.11 ) 103.10 ( 88.65 ) 115.40 ( 99.22 )
37.5 91.55 ( 78.72 ) 101.15 ( 86.97 ) 98.62 ( 84.80 ) 109.47 ( 94.12 ) 103.13 ( 88.68 ) 115.41 ( 99.23 )
37.6 91.58 ( 78.74 ) 101.17 ( 86.99 ) 98.65 ( 84.82 ) 109.48 ( 94.13 ) 103.16 ( 88.70 ) 115.42 ( 99.24 )
37.7 91.60 ( 78.76 ) 101.19 ( 87.01 ) 98.68 ( 84.85 ) 109.49 ( 94.14 ) 103.19 ( 88.73 ) 115.43 ( 99.25 )
37.8 91.63 ( 78.79 ) 101.21 ( 87.02 ) 98.71 ( 84.88 ) 109.50 ( 94.15 ) 103.22 ( 88.76 ) 115.44 ( 99.26 )
37.9 91.66 ( 78.81 ) 101.23 ( 87.04 ) 98.74 ( 84.90 ) 109.51 ( 94.16 ) 103.25 ( 88.78 ) 115.45 ( 99.27 )
38.0 91.69 ( 78.84 ) 101.25 ( 87.06 ) 98.78 ( 84.93 ) 109.52 ( 94.17 ) 103.28 ( 88.81 ) 115.47 ( 99.28 )
38.1 91.72 ( 78.86 ) 101.27 ( 87.08 ) 98.81 ( 84.96 ) 109.54 ( 94.18 ) 103.31 ( 88.83 ) 115.48 ( 99.29 )
38.2 91.74 ( 78.89 ) 101.29 ( 87.10 ) 98.84 ( 84.98 ) 109.55 ( 94.19 ) 103.35 ( 88.86 ) 115.49 ( 99.30 )
38.3 91.77 ( 78.91 ) 101.31 ( 87.11 ) 98.87 ( 85.01 ) 109.56 ( 94.20 ) 103.38 ( 88.89 ) 115.50 ( 99.31 )
38.4 91.80 ( 78.93 ) 101.33 ( 87.13 ) 98.90 ( 85.04 ) 109.57 ( 94.21 ) 103.41 ( 88.91 ) 115.51 ( 99.32 )
38.5 91.83 ( 78.96 ) 101.35 ( 87.15 ) 98.93 ( 85.06 ) 109.58 ( 94.22 ) 103.44 ( 88.94 ) 115.52 ( 99.33 )
38.6 91.86 ( 78.98 ) 101.38 ( 87.17 ) 98.96 ( 85.09 ) 109.59 ( 94.23 ) 103.47 ( 88.97 ) 115.54 ( 99.34 )
38.7 91.88 ( 79.01 ) 101.40 ( 87.18 ) 98.99 ( 85.12 ) 109.60 ( 94.24 ) 103.50 ( 88.99 ) 115.55 ( 99.35 )
38.8 91.91 ( 79.03 ) 101.42 ( 87.20 ) 99.02 ( 85.14 ) 109.62 ( 94.25 ) 103.53 ( 89.02 ) 115.56 ( 99.36 )
38.9 91.94 ( 79.05 ) 101.44 ( 87.22 ) 99.05 ( 85.17 ) 109.63 ( 94.26 ) 103.56 ( 89.05 ) 115.57 ( 99.37 )
39.0 91.97 ( 79.08 ) 101.46 ( 87.24 ) 99.09 ( 85.20 ) 109.64 ( 94.27 ) 103.59 ( 89.07 ) 115.58 ( 99.38 )
39.1 92.00 ( 79.10 ) 101.48 ( 87.26 ) 99.12 ( 85.22 ) 109.65 ( 94.28 ) 103.62 ( 89.10 ) 115.59 ( 99.39 )
39.2 92.03 ( 79.13 ) 101.50 ( 87.27 ) 99.15 ( 85.25 ) 109.66 ( 94.29 ) 103.65 ( 89.13 ) 115.60 ( 99.40 )
39.3 92.05 ( 79.15 ) 101.52 ( 87.29 ) 99.18 ( 85.28 ) 109.67 ( 94.30 ) 103.69 ( 89.15 ) 115.62 ( 99.41 )
39.4 92.08 ( 79.18 ) 101.54 ( 87.31 ) 99.21 ( 85.31 ) 109.69 ( 94.31 ) 103.72 ( 89.18 ) 115.63 ( 99.42 )
39.5 92.11 ( 79.20 ) 101.56 ( 87.33 ) 99.24 ( 85.33 ) 109.70 ( 94.32 ) 103.75 ( 89.21 ) 115.64 ( 99.43 )
39.6 92.14 ( 79.22 ) 101.58 ( 87.35 ) 99.27 ( 85.36 ) 109.71 ( 94.33 ) 103.78 ( 89.23 ) 115.65 ( 99.44 )
39.7 92.17 ( 79.25 ) 101.60 ( 87.36 ) 99.30 ( 85.39 ) 109.72 ( 94.34 ) 103.81 ( 89.26 ) 115.66 ( 99.45 )
39.8 92.19 ( 79.27 ) 101.63 ( 87.38 ) 99.33 ( 85.41 ) 109.73 ( 94.35 ) 103.84 ( 89.29 ) 115.67 ( 99.46 )
39.9 92.22 ( 79.30 ) 101.65 ( 87.40 ) 99.37 ( 85.44 ) 109.74 ( 94.36 ) 103.87 ( 89.31 ) 115.68 ( 99.47 )

1-86 FAN-2209 201709


SELECTION DATA

Table 19. Outdoor Unit Capacity (JTOR320~360VAE(U,F,R)BS1) with Total Horsepower of Combined Indoor Unit (5)
Total Outdoor Unit Capacity: kW (×1000kcal/h)
RAS-32FSXNS
JTOR320VAE(U,F,R)BS1 RAS-34FSXNS
JTOR340VAE(U,F,R)BS1 RAS-36FSXNS
JTOR360VAE(U,F,R)BS1
Cooling Heating Cooling Heating Cooling Heating
40.0 92.25 ( 79.32 ) 101.67 ( 87.42 ) 99.40 ( 85.47 ) 109.76 ( 94.37 ) 103.90 ( 89.34 ) 115.70 ( 99.48 )
40.1 92.28 ( 79.34 ) 101.69 ( 87.44 ) 99.43 ( 85.49 ) 109.77 ( 94.38 ) 103.93 ( 89.37 ) 115.71 ( 99.49 )
40.2 92.31 ( 79.37 ) 101.71 ( 87.45 ) 99.46 ( 85.52 ) 109.78 ( 94.39 ) 103.96 ( 89.39 ) 115.72 ( 99.50 )
40.3 92.33 ( 79.39 ) 101.73 ( 87.47 ) 99.49 ( 85.55 ) 109.79 ( 94.40 ) 103.99 ( 89.42 ) 115.73 ( 99.51 )
40.4 92.36 ( 79.42 ) 101.75 ( 87.49 ) 99.52 ( 85.57 ) 109.80 ( 94.41 ) 104.02 ( 89.45 ) 115.74 ( 99.52 )
40.5 92.39 ( 79.44 ) 101.77 ( 87.51 ) 99.55 ( 85.60 ) 109.81 ( 94.42 ) 104.06 ( 89.47 ) 115.75 ( 99.53 )
40.6 92.42 ( 79.47 ) 101.79 ( 87.53 ) 99.58 ( 85.63 ) 109.82 ( 94.43 ) 104.09 ( 89.50 ) 115.77 ( 99.54 )
40.7 92.45 ( 79.49 ) 101.81 ( 87.54 ) 99.61 ( 85.65 ) 109.84 ( 94.44 ) 104.12 ( 89.52 ) 115.78 ( 99.55 )
40.8 92.48 ( 79.51 ) 101.83 ( 87.56 ) 99.64 ( 85.68 ) 109.85 ( 94.45 ) 104.15 ( 89.55 ) 115.79 ( 99.56 )
40.9 92.50 ( 79.54 ) 101.85 ( 87.58 ) 99.68 ( 85.71 ) 109.86 ( 94.46 ) 104.18 ( 89.58 ) 115.80 ( 99.57 )
41.0 92.53 ( 79.56 ) 101.88 ( 87.60 ) 99.71 ( 85.73 ) 109.87 ( 94.47 ) 104.21 ( 89.60 ) 115.81 ( 99.58 )
41.1 92.56 ( 79.59 ) 101.90 ( 87.61 ) 99.74 ( 85.76 ) 109.88 ( 94.48 ) 104.24 ( 89.63 ) 115.82 ( 99.59 )
41.2 92.59 ( 79.61 ) 101.92 ( 87.63 ) 99.77 ( 85.79 ) 109.89 ( 94.49 ) 104.27 ( 89.66 ) 115.83 ( 99.60 )
41.3 92.62 ( 79.64 ) 101.94 ( 87.65 ) 99.80 ( 85.81 ) 109.91 ( 94.50 ) 104.30 ( 89.68 ) 115.85 ( 99.61 )
41.4 92.64 ( 79.66 ) 101.96 ( 87.67 ) 99.83 ( 85.84 ) 109.92 ( 94.51 ) 104.33 ( 89.71 ) 115.86 ( 99.62 )
41.5 92.67 ( 79.68 ) 101.98 ( 87.69 ) 99.86 ( 85.87 ) 109.93 ( 94.52 ) 104.36 ( 89.74 ) 115.87 ( 99.63 )
41.6 92.70 ( 79.71 ) 102.00 ( 87.70 ) 99.89 ( 85.89 ) 109.94 ( 94.53 ) 104.40 ( 89.76 ) 115.88 ( 99.64 )
41.7 99.92 ( 85.92 ) 109.95 ( 94.54 ) 104.43 ( 89.79 ) 115.89 ( 99.65 )
41.8 99.95 ( 85.95 ) 109.96 ( 94.55 ) 104.46 ( 89.82 ) 115.90 ( 99.66 )
41.9 99.99 ( 85.97 ) 109.97 ( 94.56 ) 104.49 ( 89.84 ) 115.92 ( 99.67 )
42.0 100.02 ( 86.00 ) 109.99 ( 94.57 ) 104.52 ( 89.87 ) 115.93 ( 99.68 )
42.1 100.05 ( 86.03 ) 110.00 ( 94.58 ) 104.55 ( 89.90 ) 115.94 ( 99.69 )
42.2 100.08 ( 86.05 ) 110.01 ( 94.59 ) 104.58 ( 89.92 ) 115.95 ( 99.70 )
42.3 100.11 ( 86.08 ) 110.02 ( 94.60 ) 104.61 ( 89.95 ) 115.96 ( 99.71 )
42.4 100.14 ( 86.11 ) 110.03 ( 94.61 ) 104.64 ( 89.98 ) 115.97 ( 99.72 )
42.5 100.17 ( 86.13 ) 110.04 ( 94.62 ) 104.67 ( 90.00 ) 115.98 ( 99.73 )
42.6 100.20 ( 86.16 ) 110.06 ( 94.63 ) 104.70 ( 90.03 ) 116.00 ( 99.74 )
42.7 100.23 ( 86.19 ) 110.07 ( 94.64 ) 104.73 ( 90.06 ) 116.01 ( 99.75 )
42.8 100.27 ( 86.21 ) 110.08 ( 94.65 ) 104.77 ( 90.08 ) 116.02 ( 99.76 )
42.9 100.30 ( 86.24 ) 110.09 ( 94.66 ) 104.80 ( 90.11 ) 116.03 ( 99.77 )
43.0 100.33 ( 86.27 ) 110.10 ( 94.67 ) 104.83 ( 90.14 ) 116.04 ( 99.78 )
43.1 100.36 ( 86.29 ) 110.11 ( 94.68 ) 104.86 ( 90.16 ) 116.05 ( 99.79 )
43.2 100.39 ( 86.32 ) 110.12 ( 94.69 ) 104.89 ( 90.19 ) 116.07 ( 99.80 )
43.3 100.42 ( 86.35 ) 110.14 ( 94.70 ) 104.92 ( 90.21 ) 116.08 ( 99.81 )
43.4 100.45 ( 86.37 ) 110.15 ( 94.71 ) 104.95 ( 90.24 ) 116.09 ( 99.82 )
43.5 100.48 ( 86.40 ) 110.16 ( 94.72 ) 104.98 ( 90.27 ) 116.10 ( 99.83 )
43.6 100.51 ( 86.43 ) 110.17 ( 94.73 ) 105.01 ( 90.29 ) 116.11 ( 99.84 )
43.7 100.54 ( 86.45 ) 110.18 ( 94.74 ) 105.04 ( 90.32 ) 116.12 ( 99.85 )
43.8 _ 100.58 ( 86.48 ) 110.19 ( 94.75 ) 105.07 ( 90.35 ) 116.13 ( 99.86 )
43.9 100.61 ( 86.51 ) 110.21 ( 94.76 ) 105.10 ( 90.37 ) 116.15 ( 99.87 )
44.0 100.64 ( 86.53 ) 110.22 ( 94.77 ) 105.14 ( 90.40 ) 116.16 ( 99.88 )
44.1 100.67 ( 86.56 ) 110.23 ( 94.78 ) 105.17 ( 90.43 ) 116.17 ( 99.89 )
44.2 100.70 ( 86.59 ) 110.24 ( 94.79 ) 105.20 ( 90.45 ) 116.18 ( 99.90 )
44.3 105.23 ( 90.48 ) 116.19 ( 99.91 )
44.4 105.26 ( 90.51 ) 116.20 ( 99.92 )
44.5 105.29 ( 90.53 ) 116.21 ( 99.93 )
44.6 105.32 ( 90.56 ) 116.23 ( 99.94 )
44.7 105.35 ( 90.59 ) 116.24 ( 99.95 )
44.8 105.38 ( 90.61 ) 116.25 ( 99.96 )
44.9 105.41 ( 90.64 ) 116.26 ( 99.97 )
45.0 105.44 ( 90.67 ) 116.27 ( 99.98 )
45.1 _ 105.48 ( 90.69 ) 116.28 ( 99.99 )
45.2 105.51 ( 90.72 ) 116.30 ( 100.00 )
45.3 105.54 ( 90.75 ) 116.31 ( 100.01 )
45.4 105.57 ( 90.77 ) 116.32 ( 100.02 )
45.5 105.60 ( 90.80 ) 116.33 ( 100.03 )
45.6 105.63 ( 90.83 ) 116.34 ( 100.04 )
45.7 105.66 ( 90.85 ) 116.35 ( 100.05 )
45.8 105.69 ( 90.88 ) 116.36 ( 100.06 )
45.9 105.72 ( 90.90 ) 116.38 ( 100.07 )

FAN-2209 201709 1-87


SELECTION DATA

Table 20. Outdoor Unit Capacity (JTOR320~360VAE(U,F,R)BS1) with Total Horsepower of Combined Indoor Unit (6)
Total Outdoor Unit Capacity: kW (×1000kcal/h)
RAS-32FSXNS
JTOR320VAE(U,F,R)BS1 RAS-34FSXNS
JTOR340VAE(U,F,R)BS1 RAS-36FSXNS
JTOR360VAE(U,F,R)BS1
Cooling Heating Cooling Heating Cooling Heating
46.0 105.75 ( 90.93 ) 116.39 ( 100.08 )
46.1 105.78 ( 90.96 ) 116.40 ( 100.09 )
46.2 105.81 ( 90.98 ) 116.41 ( 100.10 )
46.3 105.85 ( 91.01 ) 116.42 ( 100.11 )
46.4 _ _ 105.88 ( 91.04 ) 116.43 ( 100.12 )
46.5 105.91 ( 91.06 ) 116.45 ( 100.13 )
46.6 105.94 ( 91.09 ) 116.46 ( 100.13 )
46.7 105.97 ( 91.12 ) 116.47 ( 100.14 )
46.8 106.00 ( 91.14 ) 116.48 ( 100.15 )

1-88 FAN-2209 201709


SELECTION DATA

Table 21. Outdoor Unit Capacity (JTOR380~420VAE(U,F,R)BS1) with Total Horsepower of Combined Indoor Unit (1)
Total Outdoor Unit Capacity: kW (×1000kcal/h)
RAS-38FSXNS
JTOR380VAE(U,F,R)BS1 RAS-40FSXNS
JTOR400VAE(U,F,R)BS1 RAS-42FSXNS
JTOR420VAE(U,F,R)BS1
Cooling Heating Cooling Heating Cooling Heating
19.0 53.00 ( 45.57 ) 59.00 ( 50.73 )
19.1 53.28 ( 45.81 ) 59.31 ( 51.00 )
19.2 53.56 ( 46.05 ) 59.62 ( 51.26 )
19.3 53.84 ( 46.29 ) 59.93 ( 51.53 )
19.4 54.12 ( 46.53 ) 60.24 ( 51.80 )
_
19.5 54.39 ( 46.77 ) 60.55 ( 52.07 )
19.6 54.67 ( 47.01 ) 60.86 ( 52.33 )
19.7 54.95 ( 47.25 ) 61.17 ( 52.60 )
19.8 55.23 ( 47.49 ) 61.48 ( 52.87 )
19.9 55.51 ( 47.73 ) 61.79 ( 53.13 )
_
20.0 55.79 ( 47.97 ) 62.11 ( 53.40 ) 56.00 ( 48.15 ) 62.50 ( 53.74 )
20.1 56.07 ( 48.21 ) 62.42 ( 53.67 ) 56.28 ( 48.39 ) 62.81 ( 54.01 )
20.2 56.35 ( 48.45 ) 62.73 ( 53.93 ) 56.56 ( 48.63 ) 63.12 ( 54.28 )
20.3 56.63 ( 48.69 ) 63.04 ( 54.20 ) 56.84 ( 48.87 ) 63.44 ( 54.55 )
20.4 56.91 ( 48.93 ) 63.35 ( 54.47 ) 57.12 ( 49.11 ) 63.75 ( 54.82 )
20.5 57.18 ( 49.17 ) 63.66 ( 54.74 ) 57.40 ( 49.36 ) 64.06 ( 55.08 )
20.6 57.46 ( 49.41 ) 63.97 ( 55.00 ) 57.68 ( 49.60 ) 64.37 ( 55.35 )
20.7 57.74 ( 49.65 ) 64.28 ( 55.27 ) 57.96 ( 49.84 ) 64.69 ( 55.62 )
20.8 58.02 ( 49.89 ) 64.59 ( 55.54 ) 58.24 ( 50.08 ) 65.00 ( 55.89 )
20.9 58.30 ( 50.13 ) 64.90 ( 55.80 ) 58.52 ( 50.32 ) 65.31 ( 56.16 )
21.0 58.58 ( 50.37 ) 65.21 ( 56.07 ) 58.80 ( 50.56 ) 65.63 ( 56.43 ) 59.00 ( 50.73 ) 66.00 ( 56.75 )
21.1 58.86 ( 50.61 ) 65.52 ( 56.34 ) 59.08 ( 50.80 ) 65.94 ( 56.70 ) 59.28 ( 50.97 ) 66.31 ( 57.02 )
21.2 59.14 ( 50.85 ) 65.83 ( 56.60 ) 59.36 ( 51.04 ) 66.25 ( 56.96 ) 59.56 ( 51.21 ) 66.63 ( 57.29 )
21.3 59.42 ( 51.09 ) 66.14 ( 56.87 ) 59.64 ( 51.28 ) 66.56 ( 57.23 ) 59.84 ( 51.46 ) 66.94 ( 57.56 )
21.4 59.69 ( 51.33 ) 66.45 ( 57.14 ) 59.92 ( 51.52 ) 66.88 ( 57.50 ) 60.12 ( 51.70 ) 67.26 ( 57.83 )
21.5 59.97 ( 51.57 ) 66.76 ( 57.41 ) 60.20 ( 51.76 ) 67.19 ( 57.77 ) 60.40 ( 51.94 ) 67.57 ( 58.10 )
21.6 60.25 ( 51.81 ) 67.07 ( 57.67 ) 60.48 ( 52.00 ) 67.50 ( 58.04 ) 60.69 ( 52.18 ) 67.89 ( 58.37 )
21.7 60.53 ( 52.05 ) 67.38 ( 57.94 ) 60.76 ( 52.24 ) 67.81 ( 58.31 ) 60.97 ( 52.42 ) 68.20 ( 58.64 )
21.8 60.81 ( 52.29 ) 67.69 ( 58.21 ) 61.04 ( 52.48 ) 68.12 ( 58.58 ) 61.25 ( 52.66 ) 68.51 ( 58.91 )
21.9 61.09 ( 52.53 ) 68.01 ( 58.47 ) 61.32 ( 52.73 ) 68.44 ( 58.85 ) 61.53 ( 52.91 ) 68.83 ( 59.18 )
22.0 61.37 ( 52.77 ) 68.32 ( 58.74 ) 61.60 ( 52.97 ) 68.75 ( 59.11 ) 61.81 ( 53.15 ) 69.14 ( 59.45 )
22.1 61.65 ( 53.01 ) 68.63 ( 59.01 ) 61.88 ( 53.21 ) 69.06 ( 59.38 ) 62.09 ( 53.39 ) 69.46 ( 59.72 )
22.2 61.93 ( 53.25 ) 68.94 ( 59.28 ) 62.16 ( 53.45 ) 69.37 ( 59.65 ) 62.37 ( 53.63 ) 69.77 ( 59.99 )
22.3 62.21 ( 53.49 ) 69.25 ( 59.54 ) 62.44 ( 53.69 ) 69.69 ( 59.92 ) 62.65 ( 53.87 ) 70.09 ( 60.26 )
22.4 62.48 ( 53.73 ) 69.56 ( 59.81 ) 62.72 ( 53.93 ) 70.00 ( 60.19 ) 62.93 ( 54.11 ) 70.40 ( 60.53 )
22.5 62.76 ( 53.97 ) 69.87 ( 60.08 ) 63.00 ( 54.17 ) 70.31 ( 60.46 ) 63.21 ( 54.35 ) 70.71 ( 60.80 )
22.6 63.04 ( 54.21 ) 70.18 ( 60.34 ) 63.28 ( 54.41 ) 70.62 ( 60.73 ) 63.50 ( 54.60 ) 71.03 ( 61.07 )
22.7 63.32 ( 54.45 ) 70.49 ( 60.61 ) 63.56 ( 54.65 ) 70.94 ( 61.00 ) 63.78 ( 54.84 ) 71.34 ( 61.34 )
22.8 63.60 ( 54.69 ) 70.80 ( 60.88 ) 63.84 ( 54.89 ) 71.25 ( 61.26 ) 64.06 ( 55.08 ) 71.66 ( 61.61 )
22.9 63.88 ( 54.93 ) 71.11 ( 61.14 ) 64.12 ( 55.13 ) 71.56 ( 61.53 ) 64.34 ( 55.32 ) 71.97 ( 61.88 )
23.0 64.16 ( 55.17 ) 71.42 ( 61.41 ) 64.40 ( 55.37 ) 71.87 ( 61.80 ) 64.62 ( 55.56 ) 72.29 ( 62.15 )
23.1 64.44 ( 55.41 ) 71.73 ( 61.68 ) 64.68 ( 55.61 ) 72.19 ( 62.07 ) 64.90 ( 55.80 ) 72.60 ( 62.42 )
23.2 64.72 ( 55.65 ) 72.04 ( 61.95 ) 64.96 ( 55.86 ) 72.50 ( 62.34 ) 65.18 ( 56.05 ) 72.91 ( 62.70 )
23.3 64.99 ( 55.89 ) 72.35 ( 62.21 ) 65.24 ( 56.10 ) 72.81 ( 62.61 ) 65.46 ( 56.29 ) 73.23 ( 62.97 )
23.4 65.27 ( 56.13 ) 72.66 ( 62.48 ) 65.52 ( 56.34 ) 73.12 ( 62.88 ) 65.74 ( 56.53 ) 73.54 ( 63.24 )
23.5 65.55 ( 56.37 ) 72.97 ( 62.75 ) 65.80 ( 56.58 ) 73.44 ( 63.14 ) 66.02 ( 56.77 ) 73.86 ( 63.51 )
23.6 65.83 ( 56.60 ) 73.28 ( 63.01 ) 66.08 ( 56.82 ) 73.75 ( 63.41 ) 66.30 ( 57.01 ) 74.17 ( 63.78 )
23.7 66.11 ( 56.84 ) 73.59 ( 63.28 ) 66.36 ( 57.06 ) 74.06 ( 63.68 ) 66.59 ( 57.25 ) 74.49 ( 64.05 )
23.8 66.39 ( 57.08 ) 73.91 ( 63.55 ) 66.64 ( 57.30 ) 74.37 ( 63.95 ) 66.87 ( 57.49 ) 74.80 ( 64.32 )
23.9 66.67 ( 57.32 ) 74.22 ( 63.81 ) 66.92 ( 57.54 ) 74.69 ( 64.22 ) 67.15 ( 57.74 ) 75.11 ( 64.59 )
24.0 66.95 ( 57.56 ) 74.53 ( 64.08 ) 67.20 ( 57.78 ) 75.00 ( 64.49 ) 67.43 ( 57.98 ) 75.43 ( 64.86 )
24.1 67.23 ( 57.80 ) 74.84 ( 64.35 ) 67.48 ( 58.02 ) 75.31 ( 64.76 ) 67.71 ( 58.22 ) 75.74 ( 65.13 )
24.2 67.51 ( 58.04 ) 75.15 ( 64.62 ) 67.76 ( 58.26 ) 75.62 ( 65.03 ) 67.99 ( 58.46 ) 76.06 ( 65.40 )
24.3 67.78 ( 58.28 ) 75.46 ( 64.88 ) 68.04 ( 58.50 ) 75.94 ( 65.29 ) 68.27 ( 58.70 ) 76.37 ( 65.67 )
24.4 68.06 ( 58.52 ) 75.77 ( 65.15 ) 68.32 ( 58.74 ) 76.25 ( 65.56 ) 68.55 ( 58.94 ) 76.69 ( 65.94 )
24.5 68.34 ( 58.76 ) 76.08 ( 65.42 ) 68.60 ( 58.99 ) 76.56 ( 65.83 ) 68.83 ( 59.19 ) 77.00 ( 66.21 )
24.6 68.62 ( 59.00 ) 76.39 ( 65.68 ) 68.88 ( 59.23 ) 76.87 ( 66.10 ) 69.11 ( 59.43 ) 77.31 ( 66.48 )
24.7 68.90 ( 59.24 ) 76.70 ( 65.95 ) 69.16 ( 59.47 ) 77.19 ( 66.37 ) 69.40 ( 59.67 ) 77.63 ( 66.75 )
24.8 69.18 ( 59.48 ) 77.01 ( 66.22 ) 69.44 ( 59.71 ) 77.50 ( 66.64 ) 69.68 ( 59.91 ) 77.94 ( 67.02 )
24.9 69.46 ( 59.72 ) 77.32 ( 66.48 ) 69.72 ( 59.95 ) 77.81 ( 66.91 ) 69.96 ( 60.15 ) 78.26 ( 67.29 )

FAN-2209 201709 1-89


SELECTION DATA

Table 22. Outdoor Unit Capacity (JTOR380~420VAE(U,F,R)BS1) with Total Horsepower of Combined Indoor Unit (2)
Total Outdoor Unit Capacity: kW (×1000kcal/h)
RAS-38FSXNS
JTOR380VAE(U,F,R)BS1 RAS-40FSXNS
JTOR400VAE(U,F,R)BS1 RAS-42FSXNS
JTOR420VAE(U,F,R)BS1
Cooling Heating Cooling Heating Cooling Heating
25.0 69.74 ( 59.96 ) 77.63 ( 66.75 ) 70.00 ( 60.19 ) 78.12 ( 67.18 ) 70.24 ( 60.39 ) 78.57 ( 67.56 )
25.1 70.02 ( 60.20 ) 77.94 ( 67.02 ) 70.28 ( 60.43 ) 78.44 ( 67.44 ) 70.52 ( 60.64 ) 78.89 ( 67.83 )
25.2 70.29 ( 60.44 ) 78.25 ( 67.29 ) 70.56 ( 60.67 ) 78.75 ( 67.71 ) 70.80 ( 60.88 ) 79.20 ( 68.10 )
25.3 70.57 ( 60.68 ) 78.56 ( 67.55 ) 70.84 ( 60.91 ) 79.06 ( 67.98 ) 71.08 ( 61.12 ) 79.51 ( 68.37 )
25.4 70.85 ( 60.92 ) 78.87 ( 67.82 ) 71.12 ( 61.15 ) 79.37 ( 68.25 ) 71.36 ( 61.36 ) 79.83 ( 68.64 )
25.5 71.13 ( 61.16 ) 79.18 ( 68.09 ) 71.40 ( 61.39 ) 79.69 ( 68.52 ) 71.64 ( 61.60 ) 80.14 ( 68.91 )
25.6 71.41 ( 61.40 ) 79.49 ( 68.35 ) 71.68 ( 61.63 ) 80.00 ( 68.79 ) 71.92 ( 61.84 ) 80.46 ( 69.18 )
25.7 71.69 ( 61.64 ) 79.81 ( 68.62 ) 71.96 ( 61.87 ) 80.31 ( 69.06 ) 72.20 ( 62.08 ) 80.77 ( 69.45 )
25.8 71.97 ( 61.88 ) 80.12 ( 68.89 ) 72.24 ( 62.12 ) 80.62 ( 69.33 ) 72.49 ( 62.33 ) 81.09 ( 69.72 )
25.9 72.25 ( 62.12 ) 80.43 ( 69.15 ) 72.52 ( 62.36 ) 80.94 ( 69.59 ) 72.77 ( 62.57 ) 81.40 ( 69.99 )
26.0 72.53 ( 62.36 ) 80.74 ( 69.42 ) 72.80 ( 62.60 ) 81.25 ( 69.86 ) 73.05 ( 62.81 ) 81.71 ( 70.26 )
26.1 72.81 ( 62.60 ) 81.05 ( 69.69 ) 73.08 ( 62.84 ) 81.56 ( 70.13 ) 73.33 ( 63.05 ) 82.03 ( 70.53 )
26.2 73.08 ( 62.84 ) 81.36 ( 69.96 ) 73.36 ( 63.08 ) 81.87 ( 70.40 ) 73.61 ( 63.29 ) 82.34 ( 70.80 )
26.3 73.36 ( 63.08 ) 81.67 ( 70.22 ) 73.64 ( 63.32 ) 82.19 ( 70.67 ) 73.89 ( 63.53 ) 82.66 ( 71.07 )
26.4 73.64 ( 63.32 ) 81.98 ( 70.49 ) 73.92 ( 63.56 ) 82.50 ( 70.94 ) 74.17 ( 63.78 ) 82.97 ( 71.34 )
26.5 73.92 ( 63.56 ) 82.29 ( 70.76 ) 74.20 ( 63.80 ) 82.81 ( 71.21 ) 74.45 ( 64.02 ) 83.29 ( 71.61 )
26.6 74.20 ( 63.80 ) 82.60 ( 71.02 ) 74.48 ( 64.04 ) 83.12 ( 71.47 ) 74.73 ( 64.26 ) 83.60 ( 71.88 )
26.7 74.48 ( 64.04 ) 82.91 ( 71.29 ) 74.76 ( 64.28 ) 83.44 ( 71.74 ) 75.01 ( 64.50 ) 83.91 ( 72.15 )
26.8 74.76 ( 64.28 ) 83.22 ( 71.56 ) 75.04 ( 64.52 ) 83.75 ( 72.01 ) 75.30 ( 64.74 ) 84.23 ( 72.42 )
26.9 75.04 ( 64.52 ) 83.53 ( 71.82 ) 75.32 ( 64.76 ) 84.06 ( 72.28 ) 75.58 ( 64.98 ) 84.54 ( 72.69 )
27.0 75.32 ( 64.76 ) 83.84 ( 72.09 ) 75.60 ( 65.00 ) 84.37 ( 72.55 ) 75.86 ( 65.23 ) 84.86 ( 72.96 )
27.1 75.59 ( 65.00 ) 84.15 ( 72.36 ) 75.88 ( 65.25 ) 84.69 ( 72.82 ) 76.14 ( 65.47 ) 85.17 ( 73.23 )
27.2 75.87 ( 65.24 ) 84.46 ( 72.63 ) 76.16 ( 65.49 ) 85.00 ( 73.09 ) 76.42 ( 65.71 ) 85.49 ( 73.50 )
27.3 76.15 ( 65.48 ) 84.77 ( 72.89 ) 76.44 ( 65.73 ) 85.31 ( 73.36 ) 76.70 ( 65.95 ) 85.80 ( 73.77 )
27.4 76.43 ( 65.72 ) 85.08 ( 73.16 ) 76.72 ( 65.97 ) 85.62 ( 73.62 ) 76.98 ( 66.19 ) 86.11 ( 74.04 )
27.5 76.71 ( 65.96 ) 85.39 ( 73.43 ) 77.00 ( 66.21 ) 85.94 ( 73.89 ) 77.26 ( 66.43 ) 86.43 ( 74.32 )
27.6 76.99 ( 66.20 ) 85.71 ( 73.69 ) 77.28 ( 66.45 ) 86.25 ( 74.16 ) 77.54 ( 66.67 ) 86.74 ( 74.59 )
27.7 77.27 ( 66.44 ) 86.02 ( 73.96 ) 77.56 ( 66.69 ) 86.56 ( 74.43 ) 77.82 ( 66.92 ) 87.06 ( 74.86 )
27.8 77.55 ( 66.68 ) 86.33 ( 74.23 ) 77.84 ( 66.93 ) 86.88 ( 74.70 ) 78.10 ( 67.16 ) 87.37 ( 75.13 )
27.9 77.83 ( 66.92 ) 86.64 ( 74.49 ) 78.12 ( 67.17 ) 87.19 ( 74.97 ) 78.39 ( 67.40 ) 87.69 ( 75.40 )
28.0 78.11 ( 67.16 ) 86.95 ( 74.76 ) 78.40 ( 67.41 ) 87.50 ( 75.24 ) 78.67 ( 67.64 ) 88.00 ( 75.67 )
28.1 78.38 ( 67.40 ) 87.26 ( 75.03 ) 78.68 ( 67.65 ) 87.81 ( 75.51 ) 78.95 ( 67.88 ) 88.31 ( 75.94 )
28.2 78.66 ( 67.64 ) 87.57 ( 75.30 ) 78.96 ( 67.89 ) 88.13 ( 75.77 ) 79.23 ( 68.12 ) 88.63 ( 76.21 )
28.3 78.94 ( 67.88 ) 87.88 ( 75.56 ) 79.24 ( 68.13 ) 88.44 ( 76.04 ) 79.51 ( 68.37 ) 88.94 ( 76.48 )
28.4 79.22 ( 68.12 ) 88.19 ( 75.83 ) 79.52 ( 68.37 ) 88.75 ( 76.31 ) 79.79 ( 68.61 ) 89.26 ( 76.75 )
28.5 79.50 ( 68.36 ) 88.50 ( 76.10 ) 79.80 ( 68.62 ) 89.06 ( 76.58 ) 80.07 ( 68.85 ) 89.57 ( 77.02 )
28.6 79.78 ( 68.60 ) 88.81 ( 76.36 ) 80.08 ( 68.86 ) 89.38 ( 76.85 ) 80.35 ( 69.09 ) 89.89 ( 77.29 )
28.7 80.06 ( 68.84 ) 89.12 ( 76.63 ) 80.36 ( 69.10 ) 89.69 ( 77.12 ) 80.63 ( 69.33 ) 90.20 ( 77.56 )
28.8 80.34 ( 69.08 ) 89.43 ( 76.90 ) 80.64 ( 69.34 ) 90.00 ( 77.39 ) 80.91 ( 69.57 ) 90.51 ( 77.83 )
28.9 80.62 ( 69.32 ) 89.74 ( 77.16 ) 80.92 ( 69.58 ) 90.31 ( 77.65 ) 81.20 ( 69.82 ) 90.83 ( 78.10 )
29.0 80.89 ( 69.56 ) 90.05 ( 77.43 ) 81.20 ( 69.82 ) 90.63 ( 77.92 ) 81.48 ( 70.06 ) 91.14 ( 78.37 )
29.1 81.17 ( 69.80 ) 90.36 ( 77.70 ) 81.48 ( 70.06 ) 90.94 ( 78.19 ) 81.76 ( 70.30 ) 91.46 ( 78.64 )
29.2 81.45 ( 70.04 ) 90.67 ( 77.97 ) 81.76 ( 70.30 ) 91.25 ( 78.46 ) 82.04 ( 70.54 ) 91.77 ( 78.91 )
29.3 81.73 ( 70.28 ) 90.98 ( 78.23 ) 82.04 ( 70.54 ) 91.56 ( 78.73 ) 82.32 ( 70.78 ) 92.09 ( 79.18 )
29.4 82.01 ( 70.52 ) 91.29 ( 78.50 ) 82.32 ( 70.78 ) 91.88 ( 79.00 ) 82.60 ( 71.02 ) 92.40 ( 79.45 )
29.5 82.29 ( 70.76 ) 91.61 ( 78.77 ) 82.60 ( 71.02 ) 92.19 ( 79.27 ) 82.88 ( 71.26 ) 92.71 ( 79.72 )
29.6 82.57 ( 71.00 ) 91.92 ( 79.03 ) 82.88 ( 71.26 ) 92.50 ( 79.54 ) 83.16 ( 71.51 ) 93.03 ( 79.99 )
29.7 82.85 ( 71.24 ) 92.23 ( 79.30 ) 83.16 ( 71.50 ) 92.81 ( 79.80 ) 83.44 ( 71.75 ) 93.34 ( 80.26 )
29.8 83.13 ( 71.48 ) 92.54 ( 79.57 ) 83.44 ( 71.75 ) 93.13 ( 80.07 ) 83.72 ( 71.99 ) 93.66 ( 80.53 )
29.9 83.41 ( 71.72 ) 92.85 ( 79.83 ) 83.72 ( 71.99 ) 93.44 ( 80.34 ) 84.00 ( 72.23 ) 93.97 ( 80.80 )
30.0 83.68 ( 71.96 ) 93.16 ( 80.10 ) 84.00 ( 72.23 ) 93.75 ( 80.61 ) 84.29 ( 72.47 ) 94.29 ( 81.07 )
30.1 83.96 ( 72.20 ) 93.47 ( 80.37 ) 84.28 ( 72.47 ) 94.06 ( 80.88 ) 84.57 ( 72.71 ) 94.60 ( 81.34 )
30.2 84.24 ( 72.44 ) 93.78 ( 80.64 ) 84.56 ( 72.71 ) 94.38 ( 81.15 ) 84.85 ( 72.96 ) 94.91 ( 81.61 )
30.3 84.52 ( 72.68 ) 94.09 ( 80.90 ) 84.84 ( 72.95 ) 94.69 ( 81.42 ) 85.13 ( 73.20 ) 95.23 ( 81.88 )
30.4 84.80 ( 72.91 ) 94.40 ( 81.17 ) 85.12 ( 73.19 ) 95.00 ( 81.69 ) 85.41 ( 73.44 ) 95.54 ( 82.15 )
30.5 85.08 ( 73.15 ) 94.71 ( 81.44 ) 85.40 ( 73.43 ) 95.31 ( 81.95 ) 85.69 ( 73.68 ) 95.86 ( 82.42 )
30.6 85.36 ( 73.39 ) 95.02 ( 81.70 ) 85.68 ( 73.67 ) 95.63 ( 82.22 ) 85.97 ( 73.92 ) 96.17 ( 82.69 )
30.7 85.64 ( 73.63 ) 95.33 ( 81.97 ) 85.96 ( 73.91 ) 95.94 ( 82.49 ) 86.25 ( 74.16 ) 96.49 ( 82.96 )
30.8 85.92 ( 73.87 ) 95.64 ( 82.24 ) 86.24 ( 74.15 ) 96.25 ( 82.76 ) 86.53 ( 74.41 ) 96.80 ( 83.23 )
30.9 86.19 ( 74.11 ) 95.95 ( 82.50 ) 86.52 ( 74.39 ) 96.56 ( 83.03 ) 86.81 ( 74.65 ) 97.11 ( 83.50 )

1-90 FAN-2209 201709


SELECTION DATA

Table 23. Outdoor Unit Capacity (JTOR380~420VAE(U,F,R)BS1) with Total Horsepower of Combined Indoor Unit (3)
Total Outdoor Unit Capacity: kW (×1000kcal/h)
RAS-38FSXNS
JTOR380VAE(U,F,R)BS1 RAS-40FSXNS
JTOR400VAE(U,F,R)BS1 RAS-42FSXNS
JTOR420VAE(U,F,R)BS1
Cooling Heating Cooling Heating Cooling Heating
31.0 86.47 ( 74.35 ) 96.26 ( 82.77 ) 86.80 ( 74.63 ) 96.88 ( 83.30 ) 87.10 ( 74.89 ) 97.43 ( 83.77 )
31.1 86.75 ( 74.59 ) 96.57 ( 83.04 ) 87.08 ( 74.88 ) 97.19 ( 83.57 ) 87.38 ( 75.13 ) 97.74 ( 84.04 )
31.2 87.03 ( 74.83 ) 96.88 ( 83.31 ) 87.36 ( 75.12 ) 97.50 ( 83.83 ) 87.66 ( 75.37 ) 98.06 ( 84.31 )
31.3 87.31 ( 75.07 ) 97.19 ( 83.57 ) 87.64 ( 75.36 ) 97.81 ( 84.10 ) 87.94 ( 75.61 ) 98.37 ( 84.58 )
31.4 87.59 ( 75.31 ) 97.51 ( 83.84 ) 87.92 ( 75.60 ) 98.13 ( 84.37 ) 88.22 ( 75.85 ) 98.69 ( 84.85 )
31.5 87.87 ( 75.55 ) 97.82 ( 84.11 ) 88.20 ( 75.84 ) 98.44 ( 84.64 ) 88.50 ( 76.10 ) 99.00 ( 85.12 )
31.6 88.15 ( 75.79 ) 98.13 ( 84.37 ) 88.48 ( 76.08 ) 98.75 ( 84.91 ) 88.78 ( 76.34 ) 99.31 ( 85.39 )
31.7 88.43 ( 76.03 ) 98.44 ( 84.64 ) 88.76 ( 76.32 ) 99.06 ( 85.18 ) 89.06 ( 76.58 ) 99.63 ( 85.67 )
31.8 88.71 ( 76.27 ) 98.75 ( 84.91 ) 89.04 ( 76.56 ) 99.37 ( 85.45 ) 89.34 ( 76.82 ) 99.94 ( 85.94 )
31.9 88.98 ( 76.51 ) 99.06 ( 85.17 ) 89.32 ( 76.80 ) 99.69 ( 85.72 ) 89.62 ( 77.06 ) 100.26 ( 86.21 )
32.0 89.26 ( 76.75 ) 99.37 ( 85.44 ) 89.60 ( 77.04 ) 100.00 ( 85.98 ) 89.90 ( 77.30 ) 100.57 ( 86.48 )
32.1 89.54 ( 76.99 ) 99.68 ( 85.71 ) 89.88 ( 77.28 ) 100.31 ( 86.25 ) 90.19 ( 77.55 ) 100.89 ( 86.75 )
32.2 89.82 ( 77.23 ) 99.99 ( 85.98 ) 90.16 ( 77.52 ) 100.63 ( 86.52 ) 90.47 ( 77.79 ) 101.20 ( 87.02 )
32.3 90.10 ( 77.47 ) 100.30 ( 86.24 ) 90.44 ( 77.76 ) 100.94 ( 86.79 ) 90.75 ( 78.03 ) 101.51 ( 87.29 )
32.4 90.38 ( 77.71 ) 100.61 ( 86.51 ) 90.72 ( 78.01 ) 101.25 ( 87.06 ) 91.03 ( 78.27 ) 101.83 ( 87.56 )
32.5 90.66 ( 77.95 ) 100.92 ( 86.78 ) 91.00 ( 78.25 ) 101.56 ( 87.33 ) 91.31 ( 78.51 ) 102.14 ( 87.83 )
32.6 90.94 ( 78.19 ) 101.23 ( 87.04 ) 91.28 ( 78.49 ) 101.88 ( 87.60 ) 91.59 ( 78.75 ) 102.46 ( 88.10 )
32.7 91.22 ( 78.43 ) 101.54 ( 87.31 ) 91.56 ( 78.73 ) 102.19 ( 87.87 ) 91.87 ( 79.00 ) 102.77 ( 88.37 )
32.8 91.49 ( 78.67 ) 101.85 ( 87.58 ) 91.84 ( 78.97 ) 102.50 ( 88.13 ) 92.15 ( 79.24 ) 103.09 ( 88.64 )
32.9 91.77 ( 78.91 ) 102.16 ( 87.84 ) 92.12 ( 79.21 ) 102.81 ( 88.40 ) 92.43 ( 79.48 ) 103.40 ( 88.91 )
33.0 92.05 ( 79.15 ) 102.47 ( 88.11 ) 92.40 ( 79.45 ) 103.13 ( 88.67 ) 92.71 ( 79.72 ) 103.71 ( 89.18 )
33.1 92.33 ( 79.39 ) 102.78 ( 88.38 ) 92.68 ( 79.69 ) 103.44 ( 88.94 ) 93.00 ( 79.96 ) 104.03 ( 89.45 )
33.2 92.61 ( 79.63 ) 103.09 ( 88.65 ) 92.96 ( 79.93 ) 103.75 ( 89.21 ) 93.28 ( 80.20 ) 104.34 ( 89.72 )
33.3 92.89 ( 79.87 ) 103.41 ( 88.91 ) 93.24 ( 80.17 ) 104.06 ( 89.48 ) 93.56 ( 80.44 ) 104.66 ( 89.99 )
33.4 93.17 ( 80.11 ) 103.72 ( 89.18 ) 93.52 ( 80.41 ) 104.38 ( 89.75 ) 93.84 ( 80.69 ) 104.97 ( 90.26 )
33.5 93.45 ( 80.35 ) 104.03 ( 89.45 ) 93.80 ( 80.65 ) 104.69 ( 90.02 ) 94.12 ( 80.93 ) 105.29 ( 90.53 )
33.6 93.73 ( 80.59 ) 104.34 ( 89.71 ) 94.08 ( 80.89 ) 105.00 ( 90.28 ) 94.40 ( 81.17 ) 105.60 ( 90.80 )
33.7 94.01 ( 80.83 ) 104.65 ( 89.98 ) 94.36 ( 81.13 ) 105.31 ( 90.55 ) 94.68 ( 81.41 ) 105.91 ( 91.07 )
33.8 94.28 ( 81.07 ) 104.96 ( 90.25 ) 94.64 ( 81.38 ) 105.63 ( 90.82 ) 94.96 ( 81.65 ) 106.23 ( 91.34 )
33.9 94.56 ( 81.31 ) 105.27 ( 90.51 ) 94.92 ( 81.62 ) 105.94 ( 91.09 ) 95.24 ( 81.89 ) 106.54 ( 91.61 )
34.0 94.84 ( 81.55 ) 105.58 ( 90.78 ) 95.20 ( 81.86 ) 106.25 ( 91.36 ) 95.52 ( 82.14 ) 106.86 ( 91.88 )
34.1 95.12 ( 81.79 ) 105.89 ( 91.05 ) 95.48 ( 82.10 ) 106.56 ( 91.63 ) 95.80 ( 82.38 ) 107.17 ( 92.15 )
34.2 95.40 ( 82.03 ) 106.20 ( 91.32 ) 95.76 ( 82.34 ) 106.88 ( 91.90 ) 96.09 ( 82.62 ) 107.49 ( 92.42 )
34.3 95.68 ( 82.27 ) 106.51 ( 91.58 ) 96.04 ( 82.58 ) 107.19 ( 92.16 ) 96.37 ( 82.86 ) 107.80 ( 92.69 )
34.4 95.96 ( 82.51 ) 106.82 ( 91.85 ) 96.32 ( 82.82 ) 107.50 ( 92.43 ) 96.65 ( 83.10 ) 108.11 ( 92.96 )
34.5 96.24 ( 82.75 ) 107.13 ( 92.12 ) 96.60 ( 83.06 ) 107.81 ( 92.70 ) 96.93 ( 83.34 ) 108.43 ( 93.23 )
34.6 96.52 ( 82.99 ) 107.44 ( 92.38 ) 96.88 ( 83.30 ) 108.13 ( 92.97 ) 97.21 ( 83.59 ) 108.74 ( 93.50 )
34.7 96.79 ( 83.23 ) 107.75 ( 92.65 ) 97.16 ( 83.54 ) 108.44 ( 93.24 ) 97.49 ( 83.83 ) 109.06 ( 93.77 )
34.8 97.07 ( 83.47 ) 108.06 ( 92.92 ) 97.44 ( 83.78 ) 108.75 ( 93.51 ) 97.77 ( 84.07 ) 109.37 ( 94.04 )
34.9 97.35 ( 83.71 ) 108.37 ( 93.18 ) 97.72 ( 84.02 ) 109.06 ( 93.78 ) 98.05 ( 84.31 ) 109.69 ( 94.31 )
35.0 97.63 ( 83.95 ) 108.68 ( 93.45 ) 98.00 ( 84.26 ) 109.38 ( 94.05 ) 98.33 ( 84.55 ) 110.00 ( 94.58 )
35.1 97.91 ( 84.19 ) 108.99 ( 93.72 ) 98.28 ( 84.51 ) 109.69 ( 94.31 ) 98.61 ( 84.79 ) 110.31 ( 94.85 )
35.2 98.19 ( 84.43 ) 109.31 ( 93.99 ) 98.56 ( 84.75 ) 110.00 ( 94.58 ) 98.90 ( 85.03 ) 110.63 ( 95.12 )
35.3 98.47 ( 84.67 ) 109.62 ( 94.25 ) 98.84 ( 84.99 ) 110.31 ( 94.85 ) 99.18 ( 85.28 ) 110.94 ( 95.39 )
35.4 98.75 ( 84.91 ) 109.93 ( 94.52 ) 99.12 ( 85.23 ) 110.63 ( 95.12 ) 99.46 ( 85.52 ) 111.26 ( 95.66 )
35.5 99.03 ( 85.15 ) 110.24 ( 94.79 ) 99.40 ( 85.47 ) 110.94 ( 95.39 ) 99.74 ( 85.76 ) 111.57 ( 95.93 )
35.6 99.31 ( 85.39 ) 110.55 ( 95.05 ) 99.68 ( 85.71 ) 111.25 ( 95.66 ) 100.02 ( 86.00 ) 111.89 ( 96.20 )
35.7 99.58 ( 85.63 ) 110.86 ( 95.32 ) 99.96 ( 85.95 ) 111.56 ( 95.93 ) 100.30 ( 86.24 ) 112.20 ( 96.47 )
35.8 99.86 ( 85.87 ) 111.17 ( 95.59 ) 100.24 ( 86.19 ) 111.88 ( 96.20 ) 100.58 ( 86.48 ) 112.51 ( 96.74 )
35.9 100.14 ( 86.11 ) 111.48 ( 95.85 ) 100.52 ( 86.43 ) 112.19 ( 96.46 ) 100.86 ( 86.73 ) 112.83 ( 97.02 )
36.0 100.42 ( 86.35 ) 111.79 ( 96.12 ) 100.80 ( 86.67 ) 112.50 ( 96.73 ) 101.14 ( 86.97 ) 113.14 ( 97.29 )
36.1 100.70 ( 86.59 ) 112.10 ( 96.39 ) 101.08 ( 86.91 ) 112.81 ( 97.00 ) 101.42 ( 87.21 ) 113.46 ( 97.56 )
36.2 100.98 ( 86.83 ) 112.41 ( 96.66 ) 101.36 ( 87.15 ) 113.13 ( 97.27 ) 101.70 ( 87.45 ) 113.77 ( 97.83 )
36.3 101.26 ( 87.07 ) 112.72 ( 96.92 ) 101.64 ( 87.39 ) 113.44 ( 97.54 ) 101.99 ( 87.69 ) 114.09 ( 98.10 )
36.4 101.54 ( 87.31 ) 113.03 ( 97.19 ) 101.92 ( 87.64 ) 113.75 ( 97.81 ) 102.27 ( 87.93 ) 114.40 ( 98.37 )
36.5 101.82 ( 87.55 ) 113.34 ( 97.46 ) 102.20 ( 87.88 ) 114.06 ( 98.08 ) 102.55 ( 88.18 ) 114.71 ( 98.64 )
36.6 102.09 ( 87.79 ) 113.65 ( 97.72 ) 102.48 ( 88.12 ) 114.38 ( 98.34 ) 102.83 ( 88.42 ) 115.03 ( 98.91 )
36.7 102.37 ( 88.03 ) 113.96 ( 97.99 ) 102.76 ( 88.36 ) 114.69 ( 98.61 ) 103.11 ( 88.66 ) 115.34 ( 99.18 )
36.8 102.65 ( 88.27 ) 114.27 ( 98.26 ) 103.04 ( 88.60 ) 115.00 ( 98.88 ) 103.39 ( 88.90 ) 115.66 ( 99.45 )
36.9 102.93 ( 88.51 ) 114.58 ( 98.52 ) 103.32 ( 88.84 ) 115.31 ( 99.15 ) 103.67 ( 89.14 ) 115.97 ( 99.72 )

FAN-2209 201709 1-91


SELECTION DATA

Table 24. Outdoor Unit Capacity (JTOR380~420VAE(U,F,R)BS1) with Total Horsepower of Combined Indoor Unit (4)
Total Outdoor Unit Capacity: kW (×1000kcal/h)
RAS-38FSXNS
JTOR380VAE(U,F,R)BS1 RAS-40FSXNS
JTOR400VAE(U,F,R)BS1 RAS-42FSXNS
JTOR420VAE(U,F,R)BS1
Cooling Heating Cooling Heating Cooling Heating
37.0 103.21 ( 88.75 ) 114.89 ( 98.79 ) 103.60 ( 89.08 ) 115.63 ( 99.42 ) 103.95 ( 89.38 ) 116.29 ( 99.99 )
37.1 103.49 ( 88.98 ) 115.21 ( 99.06 ) 103.88 ( 89.32 ) 115.94 ( 99.69 ) 104.23 ( 89.62 ) 116.60 ( 100.26 )
37.2 103.77 ( 89.22 ) 115.52 ( 99.33 ) 104.16 ( 89.56 ) 116.25 ( 99.96 ) 104.51 ( 89.87 ) 116.91 ( 100.53 )
37.3 104.05 ( 89.46 ) 115.83 ( 99.59 ) 104.44 ( 89.80 ) 116.56 ( 100.23 ) 104.80 ( 90.11 ) 117.23 ( 100.80 )
37.4 104.33 ( 89.70 ) 116.14 ( 99.86 ) 104.72 ( 90.04 ) 116.88 ( 100.49 ) 105.08 ( 90.35 ) 117.54 ( 101.07 )
37.5 104.61 ( 89.94 ) 116.45 ( 100.13 ) 105.00 ( 90.28 ) 117.19 ( 100.76 ) 105.36 ( 90.59 ) 117.86 ( 101.34 )
37.6 104.88 ( 90.18 ) 116.76 ( 100.39 ) 105.28 ( 90.52 ) 117.50 ( 101.03 ) 105.64 ( 90.83 ) 118.17 ( 101.61 )
37.7 105.16 ( 90.42 ) 117.07 ( 100.66 ) 105.56 ( 90.77 ) 117.81 ( 101.30 ) 105.92 ( 91.07 ) 118.49 ( 101.88 )
37.8 105.44 ( 90.66 ) 117.38 ( 100.93 ) 105.84 ( 91.01 ) 118.13 ( 101.57 ) 106.20 ( 91.32 ) 118.80 ( 102.15 )
37.9 105.72 ( 90.90 ) 117.69 ( 101.19 ) 106.12 ( 91.25 ) 118.44 ( 101.84 ) 106.48 ( 91.56 ) 119.11 ( 102.42 )
38.0 106.00 ( 91.14 ) 118.00 ( 101.46 ) 106.40 ( 91.49 ) 118.75 ( 102.11 ) 106.76 ( 91.80 ) 119.43 ( 102.69 )
38.1 106.03 ( 91.17 ) 118.02 ( 101.48 ) 106.68 ( 91.73 ) 119.06 ( 102.38 ) 107.04 ( 92.04 ) 119.74 ( 102.96 )
38.2 106.06 ( 91.19 ) 118.04 ( 101.50 ) 106.96 ( 91.97 ) 119.38 ( 102.64 ) 107.32 ( 92.28 ) 120.06 ( 103.23 )
38.3 106.08 ( 91.22 ) 118.06 ( 101.52 ) 107.24 ( 92.21 ) 119.69 ( 102.91 ) 107.60 ( 92.52 ) 120.37 ( 103.50 )
38.4 106.11 ( 91.24 ) 118.08 ( 101.53 ) 107.52 ( 92.45 ) 120.00 ( 103.18 ) 107.89 ( 92.77 ) 120.69 ( 103.77 )
38.5 106.14 ( 91.26 ) 118.10 ( 101.55 ) 107.80 ( 92.69 ) 120.31 ( 103.45 ) 108.17 ( 93.01 ) 121.00 ( 104.04 )
38.6 106.17 ( 91.29 ) 118.12 ( 101.57 ) 108.08 ( 92.93 ) 120.63 ( 103.72 ) 108.45 ( 93.25 ) 121.31 ( 104.31 )
38.7 106.20 ( 91.31 ) 118.14 ( 101.59 ) 108.36 ( 93.17 ) 120.94 ( 103.99 ) 108.73 ( 93.49 ) 121.63 ( 104.58 )
38.8 106.22 ( 91.34 ) 118.17 ( 101.60 ) 108.64 ( 93.41 ) 121.25 ( 104.26 ) 109.01 ( 93.73 ) 121.94 ( 104.85 )
38.9 106.25 ( 91.36 ) 118.19 ( 101.62 ) 108.92 ( 93.65 ) 121.56 ( 104.52 ) 109.29 ( 93.97 ) 122.26 ( 105.12 )
39.0 106.28 ( 91.38 ) 118.21 ( 101.64 ) 109.20 ( 93.90 ) 121.88 ( 104.79 ) 109.57 ( 94.21 ) 122.57 ( 105.39 )
39.1 106.31 ( 91.41 ) 118.23 ( 101.66 ) 109.48 ( 94.14 ) 122.19 ( 105.06 ) 109.85 ( 94.46 ) 122.89 ( 105.66 )
39.2 106.33 ( 91.43 ) 118.25 ( 101.68 ) 109.76 ( 94.38 ) 122.50 ( 105.33 ) 110.13 ( 94.70 ) 123.20 ( 105.93 )
39.3 106.36 ( 91.46 ) 118.27 ( 101.69 ) 110.04 ( 94.62 ) 122.81 ( 105.60 ) 110.41 ( 94.94 ) 123.51 ( 106.20 )
39.4 106.39 ( 91.48 ) 118.29 ( 101.71 ) 110.32 ( 94.86 ) 123.13 ( 105.87 ) 110.70 ( 95.18 ) 123.83 ( 106.47 )
39.5 106.42 ( 91.50 ) 118.31 ( 101.73 ) 110.60 ( 95.10 ) 123.44 ( 106.14 ) 110.98 ( 95.42 ) 124.14 ( 106.74 )
39.6 106.45 ( 91.53 ) 118.33 ( 101.75 ) 110.88 ( 95.34 ) 123.75 ( 106.41 ) 111.26 ( 95.66 ) 124.46 ( 107.01 )
39.7 106.47 ( 91.55 ) 118.35 ( 101.76 ) 111.16 ( 95.58 ) 124.06 ( 106.67 ) 111.54 ( 95.91 ) 124.77 ( 107.28 )
39.8 106.50 ( 91.58 ) 118.37 ( 101.78 ) 111.44 ( 95.82 ) 124.38 ( 106.94 ) 111.82 ( 96.15 ) 125.09 ( 107.55 )
39.9 106.53 ( 91.60 ) 118.39 ( 101.80 ) 111.72 ( 96.06 ) 124.69 ( 107.21 ) 112.10 ( 96.39 ) 125.40 ( 107.82 )
40.0 106.56 ( 91.62 ) 118.41 ( 101.82 ) 112.00 ( 96.30 ) 125.00 ( 107.48 ) 112.38 ( 96.63 ) 125.71 ( 108.09 )
40.1 106.59 ( 91.65 ) 118.43 ( 101.84 ) 112.03 ( 96.33 ) 125.02 ( 107.50 ) 112.66 ( 96.87 ) 126.03 ( 108.37 )
40.2 106.61 ( 91.67 ) 118.46 ( 101.85 ) 112.06 ( 96.35 ) 125.04 ( 107.52 ) 112.94 ( 97.11 ) 126.34 ( 108.64 )
40.3 106.64 ( 91.70 ) 118.48 ( 101.87 ) 112.08 ( 96.37 ) 125.06 ( 107.53 ) 113.22 ( 97.35 ) 126.66 ( 108.91 )
40.4 106.67 ( 91.72 ) 118.50 ( 101.89 ) 112.11 ( 96.40 ) 125.08 ( 107.55 ) 113.50 ( 97.60 ) 126.97 ( 109.18 )
40.5 106.70 ( 91.74 ) 118.52 ( 101.91 ) 112.14 ( 96.42 ) 125.10 ( 107.57 ) 113.79 ( 97.84 ) 127.29 ( 109.45 )
40.6 106.73 ( 91.77 ) 118.54 ( 101.92 ) 112.17 ( 96.45 ) 125.13 ( 107.59 ) 114.07 ( 98.08 ) 127.60 ( 109.72 )
40.7 106.75 ( 91.79 ) 118.56 ( 101.94 ) 112.20 ( 96.47 ) 125.15 ( 107.61 ) 114.35 ( 98.32 ) 127.91 ( 109.99 )
40.8 106.78 ( 91.82 ) 118.58 ( 101.96 ) 112.22 ( 96.50 ) 125.17 ( 107.62 ) 114.63 ( 98.56 ) 128.23 ( 110.26 )
40.9 106.81 ( 91.84 ) 118.60 ( 101.98 ) 112.25 ( 96.52 ) 125.19 ( 107.64 ) 114.91 ( 98.80 ) 128.54 ( 110.53 )
41.0 106.84 ( 91.86 ) 118.62 ( 102.00 ) 112.28 ( 96.54 ) 125.21 ( 107.66 ) 115.19 ( 99.05 ) 128.86 ( 110.80 )
41.1 106.86 ( 91.89 ) 118.64 ( 102.01 ) 112.31 ( 96.57 ) 125.23 ( 107.68 ) 115.47 ( 99.29 ) 129.17 ( 111.07 )
41.2 106.89 ( 91.91 ) 118.66 ( 102.03 ) 112.34 ( 96.59 ) 125.25 ( 107.70 ) 115.75 ( 99.53 ) 129.49 ( 111.34 )
41.3 106.92 ( 91.94 ) 118.68 ( 102.05 ) 112.36 ( 96.62 ) 125.27 ( 107.71 ) 116.03 ( 99.77 ) 129.80 ( 111.61 )
41.4 106.95 ( 91.96 ) 118.70 ( 102.07 ) 112.39 ( 96.64 ) 125.29 ( 107.73 ) 116.31 ( 100.01 ) 130.11 ( 111.88 )
41.5 106.98 ( 91.98 ) 118.72 ( 102.08 ) 112.42 ( 96.66 ) 125.31 ( 107.75 ) 116.60 ( 100.25 ) 130.43 ( 112.15 )
41.6 107.00 ( 92.01 ) 118.75 ( 102.10 ) 112.45 ( 96.69 ) 125.33 ( 107.77 ) 116.88 ( 100.50 ) 130.74 ( 112.42 )
41.7 107.03 ( 92.03 ) 118.77 ( 102.12 ) 112.48 ( 96.71 ) 125.35 ( 107.79 ) 117.16 ( 100.74 ) 131.06 ( 112.69 )
41.8 107.06 ( 92.06 ) 118.79 ( 102.14 ) 112.50 ( 96.74 ) 125.38 ( 107.80 ) 117.44 ( 100.98 ) 131.37 ( 112.96 )
41.9 107.09 ( 92.08 ) 118.81 ( 102.16 ) 112.53 ( 96.76 ) 125.40 ( 107.82 ) 117.72 ( 101.22 ) 131.69 ( 113.23 )
42.0 107.12 ( 92.10 ) 118.83 ( 102.17 ) 112.56 ( 96.78 ) 125.42 ( 107.84 ) 118.00 ( 101.46 ) 132.00 ( 113.50 )
42.1 107.14 ( 92.13 ) 118.85 ( 102.19 ) 112.59 ( 96.81 ) 125.44 ( 107.86 ) 118.03 ( 101.49 ) 132.02 ( 113.52 )
42.2 107.17 ( 92.15 ) 118.87 ( 102.21 ) 112.62 ( 96.83 ) 125.46 ( 107.87 ) 118.06 ( 101.51 ) 132.04 ( 113.54 )
42.3 107.20 ( 92.17 ) 118.89 ( 102.23 ) 112.64 ( 96.86 ) 125.48 ( 107.89 ) 118.08 ( 101.53 ) 132.06 ( 113.55 )
42.4 107.23 ( 92.20 ) 118.91 ( 102.24 ) 112.67 ( 96.88 ) 125.50 ( 107.91 ) 118.11 ( 101.56 ) 132.08 ( 113.57 )
42.5 107.26 ( 92.22 ) 118.93 ( 102.26 ) 112.70 ( 96.90 ) 125.52 ( 107.93 ) 118.14 ( 101.58 ) 132.10 ( 113.59 )
42.6 107.28 ( 92.25 ) 118.95 ( 102.28 ) 112.73 ( 96.93 ) 125.54 ( 107.95 ) 118.17 ( 101.61 ) 132.13 ( 113.61 )
42.7 107.31 ( 92.27 ) 118.97 ( 102.30 ) 112.76 ( 96.95 ) 125.56 ( 107.96 ) 118.20 ( 101.63 ) 132.15 ( 113.63 )
42.8 107.34 ( 92.29 ) 118.99 ( 102.32 ) 112.78 ( 96.98 ) 125.58 ( 107.98 ) 118.22 ( 101.65 ) 132.17 ( 113.64 )
42.9 107.37 ( 92.32 ) 119.01 ( 102.33 ) 112.81 ( 97.00 ) 125.60 ( 108.00 ) 118.25 ( 101.68 ) 132.19 ( 113.66 )

1-92 FAN-2209 201709


SELECTION DATA

Table 25. Outdoor Unit Capacity (JTOR380~420VAE(U,F,R)BS1) with Total Horsepower of Combined Indoor Unit (5)
Total Outdoor Unit Capacity: kW (×1000kcal/h)
RAS-38FSXNS
JTOR380VAE(U,F,R)BS1 RAS-40FSXNS
JTOR400VAE(U,F,R)BS1 RAS-42FSXNS
JTOR420VAE(U,F,R)BS1
Cooling Heating Cooling Heating Cooling Heating
43.0 107.39 ( 92.34 ) 119.04 ( 102.35 ) 112.84 ( 97.02 ) 125.63 ( 108.02 ) 118.28 ( 101.70 ) 132.21 ( 113.68 )
43.1 107.42 ( 92.37 ) 119.06 ( 102.37 ) 112.87 ( 97.05 ) 125.65 ( 108.04 ) 118.31 ( 101.73 ) 132.23 ( 113.70 )
43.2 107.45 ( 92.39 ) 119.08 ( 102.39 ) 112.90 ( 97.07 ) 125.67 ( 108.05 ) 118.34 ( 101.75 ) 132.25 ( 113.72 )
43.3 107.48 ( 92.41 ) 119.10 ( 102.41 ) 112.92 ( 97.10 ) 125.69 ( 108.07 ) 118.37 ( 101.78 ) 132.27 ( 113.73 )
43.4 107.51 ( 92.44 ) 119.12 ( 102.42 ) 112.95 ( 97.12 ) 125.71 ( 108.09 ) 118.39 ( 101.80 ) 132.29 ( 113.75 )
43.5 107.53 ( 92.46 ) 119.14 ( 102.44 ) 112.98 ( 97.15 ) 125.73 ( 108.11 ) 118.42 ( 101.82 ) 132.31 ( 113.77 )
43.6 107.56 ( 92.49 ) 119.16 ( 102.46 ) 113.01 ( 97.17 ) 125.75 ( 108.13 ) 118.45 ( 101.85 ) 132.34 ( 113.79 )
43.7 107.59 ( 92.51 ) 119.18 ( 102.48 ) 113.04 ( 97.19 ) 125.77 ( 108.14 ) 118.48 ( 101.87 ) 132.36 ( 113.81 )
43.8 107.62 ( 92.53 ) 119.20 ( 102.49 ) 113.06 ( 97.22 ) 125.79 ( 108.16 ) 118.51 ( 101.90 ) 132.38 ( 113.82 )
43.9 107.65 ( 92.56 ) 119.22 ( 102.51 ) 113.09 ( 97.24 ) 125.81 ( 108.18 ) 118.53 ( 101.92 ) 132.40 ( 113.84 )
44.0 107.67 ( 92.58 ) 119.24 ( 102.53 ) 113.12 ( 97.27 ) 125.83 ( 108.20 ) 118.56 ( 101.94 ) 132.42 ( 113.86 )
44.1 107.70 ( 92.61 ) 119.26 ( 102.55 ) 113.15 ( 97.29 ) 125.85 ( 108.22 ) 118.59 ( 101.97 ) 132.44 ( 113.88 )
44.2 107.73 ( 92.63 ) 119.28 ( 102.57 ) 113.18 ( 97.31 ) 125.88 ( 108.23 ) 118.62 ( 101.99 ) 132.46 ( 113.90 )
44.3 107.76 ( 92.65 ) 119.30 ( 102.58 ) 113.20 ( 97.34 ) 125.90 ( 108.25 ) 118.65 ( 102.02 ) 132.48 ( 113.91 )
44.4 107.79 ( 92.68 ) 119.32 ( 102.60 ) 113.23 ( 97.36 ) 125.92 ( 108.27 ) 118.67 ( 102.04 ) 132.50 ( 113.93 )
44.5 107.81 ( 92.70 ) 119.35 ( 102.62 ) 113.26 ( 97.39 ) 125.94 ( 108.29 ) 118.70 ( 102.07 ) 132.52 ( 113.95 )
44.6 107.84 ( 92.73 ) 119.37 ( 102.64 ) 113.29 ( 97.41 ) 125.96 ( 108.30 ) 118.73 ( 102.09 ) 132.54 ( 113.97 )
44.7 107.87 ( 92.75 ) 119.39 ( 102.65 ) 113.32 ( 97.43 ) 125.98 ( 108.32 ) 118.76 ( 102.11 ) 132.57 ( 113.99 )
44.8 107.90 ( 92.77 ) 119.41 ( 102.67 ) 113.34 ( 97.46 ) 126.00 ( 108.34 ) 118.79 ( 102.14 ) 132.59 ( 114.00 )
44.9 107.92 ( 92.80 ) 119.43 ( 102.69 ) 113.37 ( 97.48 ) 126.02 ( 108.36 ) 118.81 ( 102.16 ) 132.61 ( 114.02 )
45.0 107.95 ( 92.82 ) 119.45 ( 102.71 ) 113.40 ( 97.51 ) 126.04 ( 108.38 ) 118.84 ( 102.19 ) 132.63 ( 114.04 )
45.1 107.98 ( 92.85 ) 119.47 ( 102.73 ) 113.43 ( 97.53 ) 126.06 ( 108.39 ) 118.87 ( 102.21 ) 132.65 ( 114.06 )
45.2 108.01 ( 92.87 ) 119.49 ( 102.74 ) 113.46 ( 97.55 ) 126.08 ( 108.41 ) 118.90 ( 102.23 ) 132.67 ( 114.08 )
45.3 108.04 ( 92.89 ) 119.51 ( 102.76 ) 113.48 ( 97.58 ) 126.10 ( 108.43 ) 118.93 ( 102.26 ) 132.69 ( 114.09 )
45.4 108.06 ( 92.92 ) 119.53 ( 102.78 ) 113.51 ( 97.60 ) 126.13 ( 108.45 ) 118.96 ( 102.28 ) 132.71 ( 114.11 )
45.5 108.09 ( 92.94 ) 119.55 ( 102.80 ) 113.54 ( 97.63 ) 126.15 ( 108.47 ) 118.98 ( 102.31 ) 132.73 ( 114.13 )
45.6 108.12 ( 92.97 ) 119.57 ( 102.81 ) 113.57 ( 97.65 ) 126.17 ( 108.48 ) 119.01 ( 102.33 ) 132.75 ( 114.15 )
45.7 108.15 ( 92.99 ) 119.59 ( 102.83 ) 113.60 ( 97.67 ) 126.19 ( 108.50 ) 119.04 ( 102.36 ) 132.78 ( 114.17 )
45.8 108.18 ( 93.01 ) 119.61 ( 102.85 ) 113.62 ( 97.70 ) 126.21 ( 108.52 ) 119.07 ( 102.38 ) 132.80 ( 114.18 )
45.9 108.20 ( 93.04 ) 119.64 ( 102.87 ) 113.65 ( 97.72 ) 126.23 ( 108.54 ) 119.10 ( 102.40 ) 132.82 ( 114.20 )
46.0 108.23 ( 93.06 ) 119.66 ( 102.89 ) 113.68 ( 97.75 ) 126.25 ( 108.56 ) 119.12 ( 102.43 ) 132.84 ( 114.22 )
46.1 108.26 ( 93.09 ) 119.68 ( 102.90 ) 113.71 ( 97.77 ) 126.27 ( 108.57 ) 119.15 ( 102.45 ) 132.86 ( 114.24 )
46.2 108.29 ( 93.11 ) 119.70 ( 102.92 ) 113.74 ( 97.80 ) 126.29 ( 108.59 ) 119.18 ( 102.48 ) 132.88 ( 114.26 )
46.3 108.32 ( 93.13 ) 119.72 ( 102.94 ) 113.76 ( 97.82 ) 126.31 ( 108.61 ) 119.21 ( 102.50 ) 132.90 ( 114.27 )
46.4 108.34 ( 93.16 ) 119.74 ( 102.96 ) 113.79 ( 97.84 ) 126.33 ( 108.63 ) 119.24 ( 102.52 ) 132.92 ( 114.29 )
46.5 108.37 ( 93.18 ) 119.76 ( 102.97 ) 113.82 ( 97.87 ) 126.35 ( 108.65 ) 119.26 ( 102.55 ) 132.94 ( 114.31 )
46.6 108.40 ( 93.21 ) 119.78 ( 102.99 ) 113.85 ( 97.89 ) 126.38 ( 108.66 ) 119.29 ( 102.57 ) 132.96 ( 114.33 )
46.7 108.43 ( 93.23 ) 119.80 ( 103.01 ) 113.88 ( 97.92 ) 126.40 ( 108.68 ) 119.32 ( 102.60 ) 132.98 ( 114.35 )
46.8 108.45 ( 93.25 ) 119.82 ( 103.03 ) 113.90 ( 97.94 ) 126.42 ( 108.70 ) 119.35 ( 102.62 ) 133.01 ( 114.36 )
46.9 108.48 ( 93.28 ) 119.84 ( 103.05 ) 113.93 ( 97.96 ) 126.44 ( 108.72 ) 119.38 ( 102.65 ) 133.03 ( 114.38 )
47.0 108.51 ( 93.30 ) 119.86 ( 103.06 ) 113.96 ( 97.99 ) 126.46 ( 108.73 ) 119.40 ( 102.67 ) 133.05 ( 114.40 )
47.1 108.54 ( 93.33 ) 119.88 ( 103.08 ) 113.99 ( 98.01 ) 126.48 ( 108.75 ) 119.43 ( 102.69 ) 133.07 ( 114.42 )
47.2 108.57 ( 93.35 ) 119.90 ( 103.10 ) 114.02 ( 98.04 ) 126.50 ( 108.77 ) 119.46 ( 102.72 ) 133.09 ( 114.44 )
47.3 108.59 ( 93.37 ) 119.93 ( 103.12 ) 114.04 ( 98.06 ) 126.52 ( 108.79 ) 119.49 ( 102.74 ) 133.11 ( 114.45 )
47.4 108.62 ( 93.40 ) 119.95 ( 103.13 ) 114.07 ( 98.08 ) 126.54 ( 108.81 ) 119.52 ( 102.77 ) 133.13 ( 114.47 )
47.5 108.65 ( 93.42 ) 119.97 ( 103.15 ) 114.10 ( 98.11 ) 126.56 ( 108.82 ) 119.55 ( 102.79 ) 133.15 ( 114.49 )
47.6 108.68 ( 93.45 ) 119.99 ( 103.17 ) 114.13 ( 98.13 ) 126.58 ( 108.84 ) 119.57 ( 102.81 ) 133.17 ( 114.51 )
47.7 108.71 ( 93.47 ) 120.01 ( 103.19 ) 114.16 ( 98.16 ) 126.60 ( 108.86 ) 119.60 ( 102.84 ) 133.19 ( 114.53 )
47.8 108.73 ( 93.49 ) 120.03 ( 103.21 ) 114.18 ( 98.18 ) 126.63 ( 108.88 ) 119.63 ( 102.86 ) 133.22 ( 114.54 )
47.9 108.76 ( 93.52 ) 120.05 ( 103.22 ) 114.21 ( 98.20 ) 126.65 ( 108.90 ) 119.66 ( 102.89 ) 133.24 ( 114.56 )
48.0 108.79 ( 93.54 ) 120.07 ( 103.24 ) 114.24 ( 98.23 ) 126.67 ( 108.91 ) 119.69 ( 102.91 ) 133.26 ( 114.58 )
48.1 108.82 ( 93.57 ) 120.09 ( 103.26 ) 114.27 ( 98.25 ) 126.69 ( 108.93 ) 119.71 ( 102.94 ) 133.28 ( 114.60 )
48.2 108.85 ( 93.59 ) 120.11 ( 103.28 ) 114.30 ( 98.28 ) 126.71 ( 108.95 ) 119.74 ( 102.96 ) 133.30 ( 114.62 )
48.3 108.87 ( 93.61 ) 120.13 ( 103.30 ) 114.32 ( 98.30 ) 126.73 ( 108.97 ) 119.77 ( 102.98 ) 133.32 ( 114.63 )
48.4 108.90 ( 93.64 ) 120.15 ( 103.31 ) 114.35 ( 98.33 ) 126.75 ( 108.99 ) 119.80 ( 103.01 ) 133.34 ( 114.65 )
48.5 108.93 ( 93.66 ) 120.17 ( 103.33 ) 114.38 ( 98.35 ) 126.77 ( 109.00 ) 119.83 ( 103.03 ) 133.36 ( 114.67 )
48.6 108.96 ( 93.69 ) 120.19 ( 103.35 ) 114.41 ( 98.37 ) 126.79 ( 109.02 ) 119.85 ( 103.06 ) 133.38 ( 114.69 )
48.7 108.98 ( 93.71 ) 120.22 ( 103.37 ) 114.44 ( 98.40 ) 126.81 ( 109.04 ) 119.88 ( 103.08 ) 133.40 ( 114.71 )
48.8 109.01 ( 93.73 ) 120.24 ( 103.38 ) 114.46 ( 98.42 ) 126.83 ( 109.06 ) 119.91 ( 103.10 ) 133.42 ( 114.72 )
48.9 109.04 ( 93.76 ) 120.26 ( 103.40 ) 114.49 ( 98.45 ) 126.85 ( 109.07 ) 119.94 ( 103.13 ) 133.45 ( 114.74 )

FAN-2209 201709 1-93


SELECTION DATA

Table 26. Outdoor Unit Capacity (JTOR380~420VAE(U,F,R)BS1) with Total Horsepower of Combined Indoor Unit (6)
Total Outdoor Unit Capacity: kW (×1000kcal/h)
RAS-38FSXNS
JTOR380VAE(U,F,R)BS1 RAS-40FSXNS
JTOR400VAE(U,F,R)BS1 RAS-42FSXNS
JTOR420VAE(U,F,R)BS1
Cooling Heating Cooling Heating Cooling Heating
49.0 109.07 ( 93.78 ) 120.28 ( 103.42 ) 114.52 ( 98.47 ) 126.88 ( 109.09 ) 119.97 ( 103.15 ) 133.47 ( 114.76 )
49.1 109.10 ( 93.81 ) 120.30 ( 103.44 ) 114.55 ( 98.49 ) 126.90 ( 109.11 ) 119.99 ( 103.18 ) 133.49 ( 114.78 )
49.2 109.12 ( 93.83 ) 120.32 ( 103.46 ) 114.58 ( 98.52 ) 126.92 ( 109.13 ) 120.02 ( 103.20 ) 133.51 ( 114.80 )
49.3 109.15 ( 93.85 ) 120.34 ( 103.47 ) 114.60 ( 98.54 ) 126.94 ( 109.15 ) 120.05 ( 103.23 ) 133.53 ( 114.81 )
49.4 109.18 ( 93.88 ) 120.36 ( 103.49 ) 114.63 ( 98.57 ) 126.96 ( 109.16 ) 120.08 ( 103.25 ) 133.55 ( 114.83 )
49.5 114.66 ( 98.59 ) 126.98 ( 109.18 ) 120.11 ( 103.27 ) 133.57 ( 114.85 )
49.6 114.69 ( 98.61 ) 127.00 ( 109.20 ) 120.14 ( 103.30 ) 133.59 ( 114.87 )
49.7 114.72 ( 98.64 ) 127.02 ( 109.22 ) 120.16 ( 103.32 ) 133.61 ( 114.89 )
49.8 114.74 ( 98.66 ) 127.04 ( 109.24 ) 120.19 ( 103.35 ) 133.63 ( 114.90 )
49.9 114.77 ( 98.69 ) 127.06 ( 109.25 ) 120.22 ( 103.37 ) 133.66 ( 114.92 )
50.0 114.80 ( 98.71 ) 127.08 ( 109.27 ) 120.25 ( 103.39 ) 133.68 ( 114.94 )
50.1 114.83 ( 98.73 ) 127.10 ( 109.29 ) 120.28 ( 103.42 ) 133.70 ( 114.96 )
50.2 114.86 ( 98.76 ) 127.13 ( 109.31 ) 120.30 ( 103.44 ) 133.72 ( 114.98 )
50.3 114.88 ( 98.78 ) 127.15 ( 109.33 ) 120.33 ( 103.47 ) 133.74 ( 114.99 )
50.4 114.91 ( 98.81 ) 127.17 ( 109.34 ) 120.36 ( 103.49 ) 133.76 ( 115.01 )
50.5 114.94 ( 98.83 ) 127.19 ( 109.36 ) 120.39 ( 103.52 ) 133.78 ( 115.03 )
50.6 114.97 ( 98.85 ) 127.21 ( 109.38 ) 120.42 ( 103.54 ) 133.80 ( 115.05 )
50.7 115.00 ( 98.88 ) 127.23 ( 109.40 ) 120.44 ( 103.56 ) 133.82 ( 115.07 )
50.8 115.02 ( 98.90 ) 127.25 ( 109.42 ) 120.47 ( 103.59 ) 133.84 ( 115.08 )
50.9 115.05 ( 98.93 ) 127.27 ( 109.43 ) 120.50 ( 103.61 ) 133.86 ( 115.10 )
51.0 115.08 ( 98.95 ) 127.29 ( 109.45 ) 120.53 ( 103.64 ) 133.89 ( 115.12 )
51.1 115.11 ( 98.98 ) 127.31 ( 109.47 ) 120.56 ( 103.66 ) 133.91 ( 115.14 )
51.2 115.14 ( 99.00 ) 127.33 ( 109.49 ) 120.58 ( 103.68 ) 133.93 ( 115.16 )
51.3 115.16 ( 99.02 ) 127.35 ( 109.50 ) 120.61 ( 103.71 ) 133.95 ( 115.18 )
51.4 115.19 ( 99.05 ) 127.38 ( 109.52 ) 120.64 ( 103.73 ) 133.97 ( 115.19 )
51.5 115.22 ( 99.07 ) 127.40 ( 109.54 ) 120.67 ( 103.76 ) 133.99 ( 115.21 )
51.6 115.25 ( 99.10 ) 127.42 ( 109.56 ) 120.70 ( 103.78 ) 134.01 ( 115.23 )
51.7 115.28 ( 99.12 ) 127.44 ( 109.58 ) 120.73 ( 103.81 ) 134.03 ( 115.25 )
51.8 115.30 ( 99.14 ) 127.46 ( 109.59 ) 120.75 ( 103.83 ) 134.05 ( 115.27 )
51.9 115.33 ( 99.17 ) 127.48 ( 109.61 ) 120.78 ( 103.85 ) 134.07 ( 115.28 )
52.0 115.36 ( 99.19 ) 127.50 ( 109.63 ) 120.81 ( 103.88 ) 134.10 ( 115.30 )
_
52.1 120.84 ( 103.90 ) 134.12 ( 115.32 )
52.2 120.87 ( 103.93 ) 134.14 ( 115.34 )
52.3 120.89 ( 103.95 ) 134.16 ( 115.36 )
52.4 120.92 ( 103.97 ) 134.18 ( 115.37 )
52.5 120.95 ( 104.00 ) 134.20 ( 115.39 )
52.6 120.98 ( 104.02 ) 134.22 ( 115.41 )
52.7 121.01 ( 104.05 ) 134.24 ( 115.43 )
52.8 121.03 ( 104.07 ) 134.26 ( 115.45 )
52.9 121.06 ( 104.09 ) 134.28 ( 115.46 )
53.0 121.09 ( 104.12 ) 134.30 ( 115.48 )
53.1 121.12 ( 104.14 ) 134.33 ( 115.50 )
53.2 121.15 ( 104.17 ) 134.35 ( 115.52 )
53.3 121.17 ( 104.19 ) 134.37 ( 115.54 )
_
53.4 121.20 ( 104.22 ) 134.39 ( 115.55 )
53.5 121.23 ( 104.24 ) 134.41 ( 115.57 )
53.6 121.26 ( 104.26 ) 134.43 ( 115.59 )
53.7 121.29 ( 104.29 ) 134.45 ( 115.61 )
53.8 121.32 ( 104.31 ) 134.47 ( 115.63 )
53.9 121.34 ( 104.34 ) 134.49 ( 115.64 )
54.0 121.37 ( 104.36 ) 134.51 ( 115.66 )
54.1 121.40 ( 104.38 ) 134.54 ( 115.68 )
54.2 121.43 ( 104.41 ) 134.56 ( 115.70 )
54.3 121.46 ( 104.43 ) 134.58 ( 115.72 )
54.4 121.48 ( 104.46 ) 134.60 ( 115.73 )
54.5 121.51 ( 104.48 ) 134.62 ( 115.75 )
54.6 121.54 ( 104.51 ) 134.64 ( 115.77 )

1-94 FAN-2209 201709


SELECTION DATA

Table 27. Outdoor Unit Capacity (JTOR440~480VAE(U,F,R)BS1) with Total Horsepower of Combined Indoor Unit (1)
Total Outdoor Unit Capacity: kW (×1000kcal/h)
RAS-44FSXNS
JTOR440VAE(U,F,R)BS1 RAS-46FSXNS
JTOR460VAE(U,F,R)BS1 RAS-48FSXNS
JTOR480VAE(U,F,R)BS1
Cooling Heating Cooling Heating Cooling Heating
22.0 61.00 ( 52.45 ) 70.00 ( 60.19 )
22.1 61.28 ( 52.69 ) 70.32 ( 60.46 )
22.2 61.55 ( 52.93 ) 70.64 ( 60.74 )
22.3 61.83 ( 53.17 ) 70.95 ( 61.01 )
22.4 62.11 ( 53.40 ) 71.27 ( 61.28 )
_
22.5 62.39 ( 53.64 ) 71.59 ( 61.56 )
22.6 62.66 ( 53.88 ) 71.91 ( 61.83 )
22.7 62.94 ( 54.12 ) 72.23 ( 62.10 )
22.8 63.22 ( 54.36 ) 72.55 ( 62.38 )
22.9 63.50 ( 54.60 ) 72.86 ( 62.65 )
_
23.0 63.77 ( 54.83 ) 73.18 ( 62.93 ) 64.00 ( 55.03 ) 72.50 ( 62.34 )
23.1 64.05 ( 55.07 ) 73.50 ( 63.20 ) 64.28 ( 55.27 ) 72.82 ( 62.61 )
23.2 64.33 ( 55.31 ) 73.82 ( 63.47 ) 64.56 ( 55.51 ) 73.13 ( 62.88 )
23.3 64.60 ( 55.55 ) 74.14 ( 63.75 ) 64.83 ( 55.75 ) 73.45 ( 63.15 )
23.4 64.88 ( 55.79 ) 74.45 ( 64.02 ) 65.11 ( 55.99 ) 73.76 ( 63.42 )
23.5 65.16 ( 56.03 ) 74.77 ( 64.29 ) 65.39 ( 56.23 ) 74.08 ( 63.69 )
23.6 65.44 ( 56.27 ) 75.09 ( 64.57 ) 65.67 ( 56.47 ) 74.39 ( 63.97 )
23.7 65.71 ( 56.50 ) 75.41 ( 64.84 ) 65.95 ( 56.70 ) 74.71 ( 64.24 )
23.8 65.99 ( 56.74 ) 75.73 ( 65.11 ) 66.23 ( 56.94 ) 75.02 ( 64.51 )
23.9 66.27 ( 56.98 ) 76.05 ( 65.39 ) 66.50 ( 57.18 ) 75.34 ( 64.78 )
24.0 66.55 ( 57.22 ) 76.36 ( 65.66 ) 66.78 ( 57.42 ) 75.65 ( 65.05 ) 68.00 ( 58.47 ) 75.00 ( 64.49 )
24.1 66.82 ( 57.46 ) 76.68 ( 65.93 ) 67.06 ( 57.66 ) 75.97 ( 65.32 ) 68.28 ( 58.71 ) 75.31 ( 64.76 )
24.2 67.10 ( 57.70 ) 77.00 ( 66.21 ) 67.34 ( 57.90 ) 76.28 ( 65.59 ) 68.57 ( 58.96 ) 75.62 ( 65.03 )
24.3 67.38 ( 57.93 ) 77.32 ( 66.48 ) 67.62 ( 58.14 ) 76.60 ( 65.86 ) 68.85 ( 59.20 ) 75.94 ( 65.29 )
24.4 67.65 ( 58.17 ) 77.64 ( 66.76 ) 67.90 ( 58.38 ) 76.91 ( 66.13 ) 69.13 ( 59.44 ) 76.25 ( 65.56 )
24.5 67.93 ( 58.41 ) 77.95 ( 67.03 ) 68.17 ( 58.62 ) 77.23 ( 66.40 ) 69.42 ( 59.69 ) 76.56 ( 65.83 )
24.6 68.21 ( 58.65 ) 78.27 ( 67.30 ) 68.45 ( 58.86 ) 77.54 ( 66.68 ) 69.70 ( 59.93 ) 76.87 ( 66.10 )
24.7 68.49 ( 58.89 ) 78.59 ( 67.58 ) 68.73 ( 59.10 ) 77.86 ( 66.95 ) 69.98 ( 60.17 ) 77.19 ( 66.37 )
24.8 68.76 ( 59.13 ) 78.91 ( 67.85 ) 69.01 ( 59.34 ) 78.17 ( 67.22 ) 70.27 ( 60.42 ) 77.50 ( 66.64 )
24.9 69.04 ( 59.36 ) 79.23 ( 68.12 ) 69.29 ( 59.58 ) 78.49 ( 67.49 ) 70.55 ( 60.66 ) 77.81 ( 66.91 )
25.0 69.32 ( 59.60 ) 79.55 ( 68.40 ) 69.57 ( 59.82 ) 78.80 ( 67.76 ) 70.83 ( 60.91 ) 78.12 ( 67.18 )
25.1 69.60 ( 59.84 ) 79.86 ( 68.67 ) 69.84 ( 60.05 ) 79.12 ( 68.03 ) 71.12 ( 61.15 ) 78.44 ( 67.44 )
25.2 69.87 ( 60.08 ) 80.18 ( 68.94 ) 70.12 ( 60.29 ) 79.43 ( 68.30 ) 71.40 ( 61.39 ) 78.75 ( 67.71 )
25.3 70.15 ( 60.32 ) 80.50 ( 69.22 ) 70.40 ( 60.53 ) 79.75 ( 68.57 ) 71.68 ( 61.64 ) 79.06 ( 67.98 )
25.4 70.43 ( 60.56 ) 80.82 ( 69.49 ) 70.68 ( 60.77 ) 80.07 ( 68.84 ) 71.97 ( 61.88 ) 79.37 ( 68.25 )
25.5 70.70 ( 60.79 ) 81.14 ( 69.76 ) 70.96 ( 61.01 ) 80.38 ( 69.11 ) 72.25 ( 62.12 ) 79.69 ( 68.52 )
25.6 70.98 ( 61.03 ) 81.45 ( 70.04 ) 71.23 ( 61.25 ) 80.70 ( 69.39 ) 72.53 ( 62.37 ) 80.00 ( 68.79 )
25.7 71.26 ( 61.27 ) 81.77 ( 70.31 ) 71.51 ( 61.49 ) 81.01 ( 69.66 ) 72.82 ( 62.61 ) 80.31 ( 69.06 )
25.8 71.54 ( 61.51 ) 82.09 ( 70.59 ) 71.79 ( 61.73 ) 81.33 ( 69.93 ) 73.10 ( 62.85 ) 80.62 ( 69.33 )
25.9 71.81 ( 61.75 ) 82.41 ( 70.86 ) 72.07 ( 61.97 ) 81.64 ( 70.20 ) 73.38 ( 63.10 ) 80.94 ( 69.59 )
26.0 72.09 ( 61.99 ) 82.73 ( 71.13 ) 72.35 ( 62.21 ) 81.96 ( 70.47 ) 73.67 ( 63.34 ) 81.25 ( 69.86 )
26.1 72.37 ( 62.23 ) 83.05 ( 71.41 ) 72.63 ( 62.45 ) 82.27 ( 70.74 ) 73.95 ( 63.59 ) 81.56 ( 70.13 )
26.2 72.65 ( 62.46 ) 83.36 ( 71.68 ) 72.90 ( 62.69 ) 82.59 ( 71.01 ) 74.23 ( 63.83 ) 81.87 ( 70.40 )
26.3 72.92 ( 62.70 ) 83.68 ( 71.95 ) 73.18 ( 62.93 ) 82.90 ( 71.28 ) 74.52 ( 64.07 ) 82.19 ( 70.67 )
26.4 73.20 ( 62.94 ) 84.00 ( 72.23 ) 73.46 ( 63.16 ) 83.22 ( 71.55 ) 74.80 ( 64.32 ) 82.50 ( 70.94 )
26.5 73.48 ( 63.18 ) 84.32 ( 72.50 ) 73.74 ( 63.40 ) 83.53 ( 71.83 ) 75.08 ( 64.56 ) 82.81 ( 71.21 )
26.6 73.75 ( 63.42 ) 84.64 ( 72.77 ) 74.02 ( 63.64 ) 83.85 ( 72.10 ) 75.37 ( 64.80 ) 83.12 ( 71.47 )
26.7 74.03 ( 63.66 ) 84.95 ( 73.05 ) 74.30 ( 63.88 ) 84.16 ( 72.37 ) 75.65 ( 65.05 ) 83.44 ( 71.74 )
26.8 74.31 ( 63.89 ) 85.27 ( 73.32 ) 74.57 ( 64.12 ) 84.48 ( 72.64 ) 75.93 ( 65.29 ) 83.75 ( 72.01 )
26.9 74.59 ( 64.13 ) 85.59 ( 73.59 ) 74.85 ( 64.36 ) 84.79 ( 72.91 ) 76.22 ( 65.53 ) 84.06 ( 72.28 )
27.0 74.86 ( 64.37 ) 85.91 ( 73.87 ) 75.13 ( 64.60 ) 85.11 ( 73.18 ) 76.50 ( 65.78 ) 84.37 ( 72.55 )
27.1 75.14 ( 64.61 ) 86.23 ( 74.14 ) 75.41 ( 64.84 ) 85.42 ( 73.45 ) 76.78 ( 66.02 ) 84.69 ( 72.82 )
27.2 75.42 ( 64.85 ) 86.55 ( 74.42 ) 75.69 ( 65.08 ) 85.74 ( 73.72 ) 77.07 ( 66.27 ) 85.00 ( 73.09 )
27.3 75.70 ( 65.09 ) 86.86 ( 74.69 ) 75.97 ( 65.32 ) 86.05 ( 73.99 ) 77.35 ( 66.51 ) 85.31 ( 73.36 )
27.4 75.97 ( 65.32 ) 87.18 ( 74.96 ) 76.24 ( 65.56 ) 86.37 ( 74.26 ) 77.63 ( 66.75 ) 85.62 ( 73.62 )
27.5 76.25 ( 65.56 ) 87.50 ( 75.24 ) 76.52 ( 65.80 ) 86.68 ( 74.54 ) 77.92 ( 67.00 ) 85.94 ( 73.89 )
27.6 76.53 ( 65.80 ) 87.82 ( 75.51 ) 76.80 ( 66.04 ) 87.00 ( 74.81 ) 78.20 ( 67.24 ) 86.25 ( 74.16 )
27.7 76.80 ( 66.04 ) 88.14 ( 75.78 ) 77.08 ( 66.28 ) 87.32 ( 75.08 ) 78.48 ( 67.48 ) 86.56 ( 74.43 )
27.8 77.08 ( 66.28 ) 88.45 ( 76.06 ) 77.36 ( 66.51 ) 87.63 ( 75.35 ) 78.77 ( 67.73 ) 86.88 ( 74.70 )
27.9 77.36 ( 66.52 ) 88.77 ( 76.33 ) 77.63 ( 66.75 ) 87.95 ( 75.62 ) 79.05 ( 67.97 ) 87.19 ( 74.97 )

FAN-2209 201709 1-95


SELECTION DATA

Table 28. Outdoor Unit Capacity (JTOR440~480VAE(U,F,R)BS1) with Total Horsepower of Combined Indoor Unit (2)
Total Outdoor Unit Capacity: kW (×1000kcal/h)
RAS-44FSXNS
JTOR440VAE(U,F,R)BS1 RAS-46FSXNS
JTOR460VAE(U,F,R)BS1 RAS-48FSXNS
JTOR480VAE(U,F,R)BS1
Cooling Heating Cooling Heating Cooling Heating
28.0 77.64 ( 66.76 ) 89.09 ( 76.60 ) 77.91 ( 66.99 ) 88.26 ( 75.89 ) 79.33 ( 68.21 ) 87.50 ( 75.24 )
28.1 77.91 ( 66.99 ) 89.41 ( 76.88 ) 78.19 ( 67.23 ) 88.58 ( 76.16 ) 79.62 ( 68.46 ) 87.81 ( 75.51 )
28.2 78.19 ( 67.23 ) 89.73 ( 77.15 ) 78.47 ( 67.47 ) 88.89 ( 76.43 ) 79.90 ( 68.70 ) 88.13 ( 75.77 )
28.3 78.47 ( 67.47 ) 90.05 ( 77.43 ) 78.75 ( 67.71 ) 89.21 ( 76.70 ) 80.18 ( 68.95 ) 88.44 ( 76.04 )
28.4 78.75 ( 67.71 ) 90.36 ( 77.70 ) 79.03 ( 67.95 ) 89.52 ( 76.97 ) 80.47 ( 69.19 ) 88.75 ( 76.31 )
28.5 79.02 ( 67.95 ) 90.68 ( 77.97 ) 79.30 ( 68.19 ) 89.84 ( 77.25 ) 80.75 ( 69.43 ) 89.06 ( 76.58 )
28.6 79.30 ( 68.19 ) 91.00 ( 78.25 ) 79.58 ( 68.43 ) 90.15 ( 77.52 ) 81.03 ( 69.68 ) 89.38 ( 76.85 )
28.7 79.58 ( 68.42 ) 91.32 ( 78.52 ) 79.86 ( 68.67 ) 90.47 ( 77.79 ) 81.32 ( 69.92 ) 89.69 ( 77.12 )
28.8 79.85 ( 68.66 ) 91.64 ( 78.79 ) 80.14 ( 68.91 ) 90.78 ( 78.06 ) 81.60 ( 70.16 ) 90.00 ( 77.39 )
28.9 80.13 ( 68.90 ) 91.95 ( 79.07 ) 80.42 ( 69.15 ) 91.10 ( 78.33 ) 81.88 ( 70.41 ) 90.31 ( 77.65 )
29.0 80.41 ( 69.14 ) 92.27 ( 79.34 ) 80.70 ( 69.39 ) 91.41 ( 78.60 ) 82.17 ( 70.65 ) 90.63 ( 77.92 )
29.1 80.69 ( 69.38 ) 92.59 ( 79.61 ) 80.97 ( 69.63 ) 91.73 ( 78.87 ) 82.45 ( 70.89 ) 90.94 ( 78.19 )
29.2 80.96 ( 69.62 ) 92.91 ( 79.89 ) 81.25 ( 69.86 ) 92.04 ( 79.14 ) 82.73 ( 71.14 ) 91.25 ( 78.46 )
29.3 81.24 ( 69.85 ) 93.23 ( 80.16 ) 81.53 ( 70.10 ) 92.36 ( 79.41 ) 83.02 ( 71.38 ) 91.56 ( 78.73 )
29.4 81.52 ( 70.09 ) 93.55 ( 80.43 ) 81.81 ( 70.34 ) 92.67 ( 79.69 ) 83.30 ( 71.63 ) 91.88 ( 79.00 )
29.5 81.80 ( 70.33 ) 93.86 ( 80.71 ) 82.09 ( 70.58 ) 92.99 ( 79.96 ) 83.58 ( 71.87 ) 92.19 ( 79.27 )
29.6 82.07 ( 70.57 ) 94.18 ( 80.98 ) 82.37 ( 70.82 ) 93.30 ( 80.23 ) 83.87 ( 72.11 ) 92.50 ( 79.54 )
29.7 82.35 ( 70.81 ) 94.50 ( 81.26 ) 82.64 ( 71.06 ) 93.62 ( 80.50 ) 84.15 ( 72.36 ) 92.81 ( 79.80 )
29.8 82.63 ( 71.05 ) 94.82 ( 81.53 ) 82.92 ( 71.30 ) 93.93 ( 80.77 ) 84.43 ( 72.60 ) 93.13 ( 80.07 )
29.9 82.90 ( 71.29 ) 95.14 ( 81.80 ) 83.20 ( 71.54 ) 94.25 ( 81.04 ) 84.72 ( 72.84 ) 93.44 ( 80.34 )
30.0 83.18 ( 71.52 ) 95.45 ( 82.08 ) 83.48 ( 71.78 ) 94.57 ( 81.31 ) 85.00 ( 73.09 ) 93.75 ( 80.61 )
30.1 83.46 ( 71.76 ) 95.77 ( 82.35 ) 83.76 ( 72.02 ) 94.88 ( 81.58 ) 85.28 ( 73.33 ) 94.06 ( 80.88 )
30.2 83.74 ( 72.00 ) 96.09 ( 82.62 ) 84.03 ( 72.26 ) 95.20 ( 81.85 ) 85.57 ( 73.57 ) 94.38 ( 81.15 )
30.3 84.01 ( 72.24 ) 96.41 ( 82.90 ) 84.31 ( 72.50 ) 95.51 ( 82.12 ) 85.85 ( 73.82 ) 94.69 ( 81.42 )
30.4 84.29 ( 72.48 ) 96.73 ( 83.17 ) 84.59 ( 72.74 ) 95.83 ( 82.40 ) 86.13 ( 74.06 ) 95.00 ( 81.69 )
30.5 84.57 ( 72.72 ) 97.05 ( 83.44 ) 84.87 ( 72.97 ) 96.14 ( 82.67 ) 86.42 ( 74.30 ) 95.31 ( 81.95 )
30.6 84.85 ( 72.95 ) 97.36 ( 83.72 ) 85.15 ( 73.21 ) 96.46 ( 82.94 ) 86.70 ( 74.55 ) 95.62 ( 82.22 )
30.7 85.12 ( 73.19 ) 97.68 ( 83.99 ) 85.43 ( 73.45 ) 96.77 ( 83.21 ) 86.98 ( 74.79 ) 95.94 ( 82.49 )
30.8 85.40 ( 73.43 ) 98.00 ( 84.26 ) 85.70 ( 73.69 ) 97.09 ( 83.48 ) 87.27 ( 75.04 ) 96.25 ( 82.76 )
30.9 85.68 ( 73.67 ) 98.32 ( 84.54 ) 85.98 ( 73.93 ) 97.40 ( 83.75 ) 87.55 ( 75.28 ) 96.56 ( 83.03 )
31.0 85.95 ( 73.91 ) 98.64 ( 84.81 ) 86.26 ( 74.17 ) 97.72 ( 84.02 ) 87.83 ( 75.52 ) 96.87 ( 83.30 )
31.1 86.23 ( 74.15 ) 98.95 ( 85.09 ) 86.54 ( 74.41 ) 98.03 ( 84.29 ) 88.12 ( 75.77 ) 97.19 ( 83.57 )
31.2 86.51 ( 74.38 ) 99.27 ( 85.36 ) 86.82 ( 74.65 ) 98.35 ( 84.56 ) 88.40 ( 76.01 ) 97.50 ( 83.83 )
31.3 86.79 ( 74.62 ) 99.59 ( 85.63 ) 87.10 ( 74.89 ) 98.66 ( 84.83 ) 88.68 ( 76.25 ) 97.81 ( 84.10 )
31.4 87.06 ( 74.86 ) 99.91 ( 85.91 ) 87.37 ( 75.13 ) 98.98 ( 85.11 ) 88.97 ( 76.50 ) 98.12 ( 84.37 )
31.5 87.34 ( 75.10 ) 100.23 ( 86.18 ) 87.65 ( 75.37 ) 99.29 ( 85.38 ) 89.25 ( 76.74 ) 98.44 ( 84.64 )
31.6 87.62 ( 75.34 ) 100.55 ( 86.45 ) 87.93 ( 75.61 ) 99.61 ( 85.65 ) 89.53 ( 76.98 ) 98.75 ( 84.91 )
31.7 87.90 ( 75.58 ) 100.86 ( 86.73 ) 88.21 ( 75.85 ) 99.92 ( 85.92 ) 89.82 ( 77.23 ) 99.06 ( 85.18 )
31.8 88.17 ( 75.81 ) 101.18 ( 87.00 ) 88.49 ( 76.09 ) 100.24 ( 86.19 ) 90.10 ( 77.47 ) 99.37 ( 85.45 )
31.9 88.45 ( 76.05 ) 101.50 ( 87.27 ) 88.77 ( 76.32 ) 100.55 ( 86.46 ) 90.38 ( 77.72 ) 99.69 ( 85.72 )
32.0 88.73 ( 76.29 ) 101.82 ( 87.55 ) 89.04 ( 76.56 ) 100.87 ( 86.73 ) 90.67 ( 77.96 ) 100.00 ( 85.98 )
32.1 89.00 ( 76.53 ) 102.14 ( 87.82 ) 89.32 ( 76.80 ) 101.18 ( 87.00 ) 90.95 ( 78.20 ) 100.31 ( 86.25 )
32.2 89.28 ( 76.77 ) 102.45 ( 88.10 ) 89.60 ( 77.04 ) 101.50 ( 87.27 ) 91.23 ( 78.45 ) 100.63 ( 86.52 )
32.3 89.56 ( 77.01 ) 102.77 ( 88.37 ) 89.88 ( 77.28 ) 101.82 ( 87.55 ) 91.52 ( 78.69 ) 100.94 ( 86.79 )
32.4 89.84 ( 77.25 ) 103.09 ( 88.64 ) 90.16 ( 77.52 ) 102.13 ( 87.82 ) 91.80 ( 78.93 ) 101.25 ( 87.06 )
32.5 90.11 ( 77.48 ) 103.41 ( 88.92 ) 90.43 ( 77.76 ) 102.45 ( 88.09 ) 92.08 ( 79.18 ) 101.56 ( 87.33 )
32.6 90.39 ( 77.72 ) 103.73 ( 89.19 ) 90.71 ( 78.00 ) 102.76 ( 88.36 ) 92.37 ( 79.42 ) 101.88 ( 87.60 )
32.7 90.67 ( 77.96 ) 104.05 ( 89.46 ) 90.99 ( 78.24 ) 103.08 ( 88.63 ) 92.65 ( 79.66 ) 102.19 ( 87.87 )
32.8 90.95 ( 78.20 ) 104.36 ( 89.74 ) 91.27 ( 78.48 ) 103.39 ( 88.90 ) 92.93 ( 79.91 ) 102.50 ( 88.13 )
32.9 91.22 ( 78.44 ) 104.68 ( 90.01 ) 91.55 ( 78.72 ) 103.71 ( 89.17 ) 93.22 ( 80.15 ) 102.81 ( 88.40 )
33.0 91.50 ( 78.68 ) 105.00 ( 90.28 ) 91.83 ( 78.96 ) 104.02 ( 89.44 ) 93.50 ( 80.40 ) 103.13 ( 88.67 )
33.1 91.78 ( 78.91 ) 105.32 ( 90.56 ) 92.10 ( 79.20 ) 104.34 ( 89.71 ) 93.78 ( 80.64 ) 103.44 ( 88.94 )
33.2 92.05 ( 79.15 ) 105.64 ( 90.83 ) 92.38 ( 79.43 ) 104.65 ( 89.98 ) 94.07 ( 80.88 ) 103.75 ( 89.21 )
33.3 92.33 ( 79.39 ) 105.95 ( 91.10 ) 92.66 ( 79.67 ) 104.97 ( 90.26 ) 94.35 ( 81.13 ) 104.06 ( 89.48 )
33.4 92.61 ( 79.63 ) 106.27 ( 91.38 ) 92.94 ( 79.91 ) 105.28 ( 90.53 ) 94.63 ( 81.37 ) 104.38 ( 89.75 )
33.5 92.89 ( 79.87 ) 106.59 ( 91.65 ) 93.22 ( 80.15 ) 105.60 ( 90.80 ) 94.92 ( 81.61 ) 104.69 ( 90.02 )
33.6 93.16 ( 80.11 ) 106.91 ( 91.93 ) 93.50 ( 80.39 ) 105.91 ( 91.07 ) 95.20 ( 81.86 ) 105.00 ( 90.28 )
33.7 93.44 ( 80.34 ) 107.23 ( 92.20 ) 93.77 ( 80.63 ) 106.23 ( 91.34 ) 95.48 ( 82.10 ) 105.31 ( 90.55 )
33.8 93.72 ( 80.58 ) 107.55 ( 92.47 ) 94.05 ( 80.87 ) 106.54 ( 91.61 ) 95.77 ( 82.34 ) 105.63 ( 90.82 )
33.9 94.00 ( 80.82 ) 107.86 ( 92.75 ) 94.33 ( 81.11 ) 106.86 ( 91.88 ) 96.05 ( 82.59 ) 105.94 ( 91.09 )

1-96 FAN-2209 201709


SELECTION DATA

Table 29. Outdoor Unit Capacity (JTOR440~480VAE(U,F,R)BS1) with Total Horsepower of Combined Indoor Unit (3)
Total Outdoor Unit Capacity: kW (×1000kcal/h)
RAS-44FSXNS
JTOR440VAE(U,F,R)BS1 RAS-46FSXNS
JTOR460VAE(U,F,R)BS1 RAS-48FSXNS
JTOR480VAE(U,F,R)BS1
Cooling Heating Cooling Heating Cooling Heating
34.0 94.27 ( 81.06 ) 108.18 ( 93.02 ) 94.61 ( 81.35 ) 107.17 ( 92.15 ) 96.33 ( 82.83 ) 106.25 ( 91.36 )
34.1 94.55 ( 81.30 ) 108.50 ( 93.29 ) 94.89 ( 81.59 ) 107.49 ( 92.42 ) 96.62 ( 83.08 ) 106.56 ( 91.63 )
34.2 94.83 ( 81.54 ) 108.82 ( 93.57 ) 95.17 ( 81.83 ) 107.80 ( 92.70 ) 96.90 ( 83.32 ) 106.88 ( 91.90 )
34.3 95.10 ( 81.78 ) 109.14 ( 93.84 ) 95.44 ( 82.07 ) 108.12 ( 92.97 ) 97.18 ( 83.56 ) 107.19 ( 92.16 )
34.4 95.38 ( 82.01 ) 109.45 ( 94.11 ) 95.72 ( 82.31 ) 108.43 ( 93.24 ) 97.47 ( 83.81 ) 107.50 ( 92.43 )
34.5 95.66 ( 82.25 ) 109.77 ( 94.39 ) 96.00 ( 82.55 ) 108.75 ( 93.51 ) 97.75 ( 84.05 ) 107.81 ( 92.70 )
34.6 95.94 ( 82.49 ) 110.09 ( 94.66 ) 96.28 ( 82.78 ) 109.07 ( 93.78 ) 98.03 ( 84.29 ) 108.13 ( 92.97 )
34.7 96.21 ( 82.73 ) 110.41 ( 94.93 ) 96.56 ( 83.02 ) 109.38 ( 94.05 ) 98.32 ( 84.54 ) 108.44 ( 93.24 )
34.8 96.49 ( 82.97 ) 110.73 ( 95.21 ) 96.83 ( 83.26 ) 109.70 ( 94.32 ) 98.60 ( 84.78 ) 108.75 ( 93.51 )
34.9 96.77 ( 83.21 ) 111.05 ( 95.48 ) 97.11 ( 83.50 ) 110.01 ( 94.59 ) 98.88 ( 85.02 ) 109.06 ( 93.78 )
35.0 97.05 ( 83.44 ) 111.36 ( 95.76 ) 97.39 ( 83.74 ) 110.33 ( 94.86 ) 99.17 ( 85.27 ) 109.38 ( 94.05 )
35.1 97.32 ( 83.68 ) 111.68 ( 96.03 ) 97.67 ( 83.98 ) 110.64 ( 95.13 ) 99.45 ( 85.51 ) 109.69 ( 94.31 )
35.2 97.60 ( 83.92 ) 112.00 ( 96.30 ) 97.95 ( 84.22 ) 110.96 ( 95.41 ) 99.73 ( 85.76 ) 110.00 ( 94.58 )
35.3 97.88 ( 84.16 ) 112.32 ( 96.58 ) 98.23 ( 84.46 ) 111.27 ( 95.68 ) 100.02 ( 86.00 ) 110.31 ( 94.85 )
35.4 98.15 ( 84.40 ) 112.64 ( 96.85 ) 98.50 ( 84.70 ) 111.59 ( 95.95 ) 100.30 ( 86.24 ) 110.63 ( 95.12 )
35.5 98.43 ( 84.64 ) 112.95 ( 97.12 ) 98.78 ( 84.94 ) 111.90 ( 96.22 ) 100.58 ( 86.49 ) 110.94 ( 95.39 )
35.6 98.71 ( 84.87 ) 113.27 ( 97.40 ) 99.06 ( 85.18 ) 112.22 ( 96.49 ) 100.87 ( 86.73 ) 111.25 ( 95.66 )
35.7 98.99 ( 85.11 ) 113.59 ( 97.67 ) 99.34 ( 85.42 ) 112.53 ( 96.76 ) 101.15 ( 86.97 ) 111.56 ( 95.93 )
35.8 99.26 ( 85.35 ) 113.91 ( 97.94 ) 99.62 ( 85.66 ) 112.85 ( 97.03 ) 101.43 ( 87.22 ) 111.88 ( 96.20 )
35.9 99.54 ( 85.59 ) 114.23 ( 98.22 ) 99.90 ( 85.89 ) 113.16 ( 97.30 ) 101.72 ( 87.46 ) 112.19 ( 96.46 )
36.0 99.82 ( 85.83 ) 114.55 ( 98.49 ) 100.17 ( 86.13 ) 113.48 ( 97.57 ) 102.00 ( 87.70 ) 112.50 ( 96.73 )
36.1 100.10 ( 86.07 ) 114.86 ( 98.76 ) 100.45 ( 86.37 ) 113.79 ( 97.84 ) 102.28 ( 87.95 ) 112.81 ( 97.00 )
36.2 100.37 ( 86.31 ) 115.18 ( 99.04 ) 100.73 ( 86.61 ) 114.11 ( 98.12 ) 102.57 ( 88.19 ) 113.13 ( 97.27 )
36.3 100.65 ( 86.54 ) 115.50 ( 99.31 ) 101.01 ( 86.85 ) 114.42 ( 98.39 ) 102.85 ( 88.44 ) 113.44 ( 97.54 )
36.4 100.93 ( 86.78 ) 115.82 ( 99.59 ) 101.29 ( 87.09 ) 114.74 ( 98.66 ) 103.13 ( 88.68 ) 113.75 ( 97.81 )
36.5 101.20 ( 87.02 ) 116.14 ( 99.86 ) 101.57 ( 87.33 ) 115.05 ( 98.93 ) 103.42 ( 88.92 ) 114.06 ( 98.08 )
36.6 101.48 ( 87.26 ) 116.45 ( 100.13 ) 101.84 ( 87.57 ) 115.37 ( 99.20 ) 103.70 ( 89.17 ) 114.38 ( 98.34 )
36.7 101.76 ( 87.50 ) 116.77 ( 100.41 ) 102.12 ( 87.81 ) 115.68 ( 99.47 ) 103.98 ( 89.41 ) 114.69 ( 98.61 )
36.8 102.04 ( 87.74 ) 117.09 ( 100.68 ) 102.40 ( 88.05 ) 116.00 ( 99.74 ) 104.27 ( 89.65 ) 115.00 ( 98.88 )
36.9 102.31 ( 87.97 ) 117.41 ( 100.95 ) 102.68 ( 88.29 ) 116.32 ( 100.01 ) 104.55 ( 89.90 ) 115.31 ( 99.15 )
37.0 102.59 ( 88.21 ) 117.73 ( 101.23 ) 102.96 ( 88.53 ) 116.63 ( 100.28 ) 104.83 ( 90.14 ) 115.63 ( 99.42 )
37.1 102.87 ( 88.45 ) 118.05 ( 101.50 ) 103.23 ( 88.77 ) 116.95 ( 100.56 ) 105.12 ( 90.38 ) 115.94 ( 99.69 )
37.2 103.15 ( 88.69 ) 118.36 ( 101.77 ) 103.51 ( 89.01 ) 117.26 ( 100.83 ) 105.40 ( 90.63 ) 116.25 ( 99.96 )
37.3 103.42 ( 88.93 ) 118.68 ( 102.05 ) 103.79 ( 89.24 ) 117.58 ( 101.10 ) 105.68 ( 90.87 ) 116.56 ( 100.23 )
37.4 103.70 ( 89.17 ) 119.00 ( 102.32 ) 104.07 ( 89.48 ) 117.89 ( 101.37 ) 105.97 ( 91.11 ) 116.88 ( 100.49 )
37.5 103.98 ( 89.40 ) 119.32 ( 102.60 ) 104.35 ( 89.72 ) 118.21 ( 101.64 ) 106.25 ( 91.36 ) 117.19 ( 100.76 )
37.6 104.25 ( 89.64 ) 119.64 ( 102.87 ) 104.63 ( 89.96 ) 118.52 ( 101.91 ) 106.53 ( 91.60 ) 117.50 ( 101.03 )
37.7 104.53 ( 89.88 ) 119.95 ( 103.14 ) 104.90 ( 90.20 ) 118.84 ( 102.18 ) 106.82 ( 91.85 ) 117.81 ( 101.30 )
37.8 104.81 ( 90.12 ) 120.27 ( 103.42 ) 105.18 ( 90.44 ) 119.15 ( 102.45 ) 107.10 ( 92.09 ) 118.13 ( 101.57 )
37.9 105.09 ( 90.36 ) 120.59 ( 103.69 ) 105.46 ( 90.68 ) 119.47 ( 102.72 ) 107.38 ( 92.33 ) 118.44 ( 101.84 )
38.0 105.36 ( 90.60 ) 120.91 ( 103.96 ) 105.74 ( 90.92 ) 119.78 ( 102.99 ) 107.67 ( 92.58 ) 118.75 ( 102.11 )
38.1 105.64 ( 90.83 ) 121.23 ( 104.24 ) 106.02 ( 91.16 ) 120.10 ( 103.27 ) 107.95 ( 92.82 ) 119.06 ( 102.38 )
38.2 105.92 ( 91.07 ) 121.55 ( 104.51 ) 106.30 ( 91.40 ) 120.41 ( 103.54 ) 108.23 ( 93.06 ) 119.38 ( 102.64 )
38.3 106.20 ( 91.31 ) 121.86 ( 104.78 ) 106.57 ( 91.64 ) 120.73 ( 103.81 ) 108.52 ( 93.31 ) 119.69 ( 102.91 )
38.4 106.47 ( 91.55 ) 122.18 ( 105.06 ) 106.85 ( 91.88 ) 121.04 ( 104.08 ) 108.80 ( 93.55 ) 120.00 ( 103.18 )
38.5 106.75 ( 91.79 ) 122.50 ( 105.33 ) 107.13 ( 92.12 ) 121.36 ( 104.35 ) 109.08 ( 93.79 ) 120.31 ( 103.45 )
38.6 107.03 ( 92.03 ) 122.82 ( 105.60 ) 107.41 ( 92.35 ) 121.67 ( 104.62 ) 109.37 ( 94.04 ) 120.63 ( 103.72 )
38.7 107.30 ( 92.27 ) 123.14 ( 105.88 ) 107.69 ( 92.59 ) 121.99 ( 104.89 ) 109.65 ( 94.28 ) 120.94 ( 103.99 )
38.8 107.58 ( 92.50 ) 123.45 ( 106.15 ) 107.97 ( 92.83 ) 122.30 ( 105.16 ) 109.93 ( 94.53 ) 121.25 ( 104.26 )
38.9 107.86 ( 92.74 ) 123.77 ( 106.43 ) 108.24 ( 93.07 ) 122.62 ( 105.43 ) 110.22 ( 94.77 ) 121.56 ( 104.52 )
39.0 108.14 ( 92.98 ) 124.09 ( 106.70 ) 108.52 ( 93.31 ) 122.93 ( 105.70 ) 110.50 ( 95.01 ) 121.88 ( 104.79 )
39.1 108.41 ( 93.22 ) 124.41 ( 106.97 ) 108.80 ( 93.55 ) 123.25 ( 105.98 ) 110.78 ( 95.26 ) 122.19 ( 105.06 )
39.2 108.69 ( 93.46 ) 124.73 ( 107.25 ) 109.08 ( 93.79 ) 123.57 ( 106.25 ) 111.07 ( 95.50 ) 122.50 ( 105.33 )
39.3 108.97 ( 93.70 ) 125.05 ( 107.52 ) 109.36 ( 94.03 ) 123.88 ( 106.52 ) 111.35 ( 95.74 ) 122.81 ( 105.60 )
39.4 109.25 ( 93.93 ) 125.36 ( 107.79 ) 109.63 ( 94.27 ) 124.20 ( 106.79 ) 111.63 ( 95.99 ) 123.13 ( 105.87 )
39.5 109.52 ( 94.17 ) 125.68 ( 108.07 ) 109.91 ( 94.51 ) 124.51 ( 107.06 ) 111.92 ( 96.23 ) 123.44 ( 106.14 )
39.6 109.80 ( 94.41 ) 126.00 ( 108.34 ) 110.19 ( 94.75 ) 124.83 ( 107.33 ) 112.20 ( 96.47 ) 123.75 ( 106.41 )
39.7 110.08 ( 94.65 ) 126.32 ( 108.61 ) 110.47 ( 94.99 ) 125.14 ( 107.60 ) 112.48 ( 96.72 ) 124.06 ( 106.67 )
39.8 110.35 ( 94.89 ) 126.64 ( 108.89 ) 110.75 ( 95.23 ) 125.46 ( 107.87 ) 112.77 ( 96.96 ) 124.38 ( 106.94 )
39.9 110.63 ( 95.13 ) 126.95 ( 109.16 ) 111.03 ( 95.47 ) 125.77 ( 108.14 ) 113.05 ( 97.21 ) 124.69 ( 107.21 )

FAN-2209 201709 1-97


SELECTION DATA

Table 30. Outdoor Unit Capacity (JTOR440~480VAE(U,F,R)BS1) with Total Horsepower of Combined Indoor Unit (4)
Total Outdoor Unit Capacity: kW (×1000kcal/h)
RAS-44FSXNS
JTOR440VAE(U,F,R)BS1 RAS-46FSXNS
JTOR460VAE(U,F,R)BS1 RAS-48FSXNS
JTOR480VAE(U,F,R)BS1
Cooling Heating Cooling Heating Cooling Heating
40.0 110.91 ( 95.36 ) 127.27 ( 109.43 ) 111.30 ( 95.70 ) 126.09 ( 108.42 ) 113.33 ( 97.45 ) 125.00 ( 107.48 )
40.1 111.19 ( 95.60 ) 127.59 ( 109.71 ) 111.58 ( 95.94 ) 126.40 ( 108.69 ) 113.62 ( 97.69 ) 125.31 ( 107.75 )
40.2 111.46 ( 95.84 ) 127.91 ( 109.98 ) 111.86 ( 96.18 ) 126.72 ( 108.96 ) 113.90 ( 97.94 ) 125.63 ( 108.02 )
40.3 111.74 ( 96.08 ) 128.23 ( 110.26 ) 112.14 ( 96.42 ) 127.03 ( 109.23 ) 114.18 ( 98.18 ) 125.94 ( 108.29 )
40.4 112.02 ( 96.32 ) 128.55 ( 110.53 ) 112.42 ( 96.66 ) 127.35 ( 109.50 ) 114.47 ( 98.42 ) 126.25 ( 108.56 )
40.5 112.30 ( 96.56 ) 128.86 ( 110.80 ) 112.70 ( 96.90 ) 127.66 ( 109.77 ) 114.75 ( 98.67 ) 126.56 ( 108.82 )
40.6 112.57 ( 96.80 ) 129.18 ( 111.08 ) 112.97 ( 97.14 ) 127.98 ( 110.04 ) 115.03 ( 98.91 ) 126.88 ( 109.09 )
40.7 112.85 ( 97.03 ) 129.50 ( 111.35 ) 113.25 ( 97.38 ) 128.29 ( 110.31 ) 115.32 ( 99.15 ) 127.19 ( 109.36 )
40.8 113.13 ( 97.27 ) 129.82 ( 111.62 ) 113.53 ( 97.62 ) 128.61 ( 110.58 ) 115.60 ( 99.40 ) 127.50 ( 109.63 )
40.9 113.40 ( 97.51 ) 130.14 ( 111.90 ) 113.81 ( 97.86 ) 128.92 ( 110.85 ) 115.88 ( 99.64 ) 127.81 ( 109.90 )
41.0 113.68 ( 97.75 ) 130.45 ( 112.17 ) 114.09 ( 98.10 ) 129.24 ( 111.13 ) 116.17 ( 99.89 ) 128.13 ( 110.17 )
41.1 113.96 ( 97.99 ) 130.77 ( 112.44 ) 114.37 ( 98.34 ) 129.55 ( 111.40 ) 116.45 ( 100.13 ) 128.44 ( 110.44 )
41.2 114.24 ( 98.23 ) 131.09 ( 112.72 ) 114.64 ( 98.58 ) 129.87 ( 111.67 ) 116.73 ( 100.37 ) 128.75 ( 110.71 )
41.3 114.51 ( 98.46 ) 131.41 ( 112.99 ) 114.92 ( 98.81 ) 130.18 ( 111.94 ) 117.02 ( 100.62 ) 129.06 ( 110.97 )
41.4 114.79 ( 98.70 ) 131.73 ( 113.27 ) 115.20 ( 99.05 ) 130.50 ( 112.21 ) 117.30 ( 100.86 ) 129.38 ( 111.24 )
41.5 115.07 ( 98.94 ) 132.05 ( 113.54 ) 115.48 ( 99.29 ) 130.82 ( 112.48 ) 117.58 ( 101.10 ) 129.69 ( 111.51 )
41.6 115.35 ( 99.18 ) 132.36 ( 113.81 ) 115.76 ( 99.53 ) 131.13 ( 112.75 ) 117.87 ( 101.35 ) 130.00 ( 111.78 )
41.7 115.62 ( 99.42 ) 132.68 ( 114.09 ) 116.03 ( 99.77 ) 131.45 ( 113.02 ) 118.15 ( 101.59 ) 130.31 ( 112.05 )
41.8 115.90 ( 99.66 ) 133.00 ( 114.36 ) 116.31 ( 100.01 ) 131.76 ( 113.29 ) 118.43 ( 101.83 ) 130.63 ( 112.32 )
41.9 116.18 ( 99.89 ) 133.32 ( 114.63 ) 116.59 ( 100.25 ) 132.08 ( 113.56 ) 118.72 ( 102.08 ) 130.94 ( 112.59 )
42.0 116.45 ( 100.13 ) 133.64 ( 114.91 ) 116.87 ( 100.49 ) 132.39 ( 113.84 ) 119.00 ( 102.32 ) 131.25 ( 112.85 )
42.1 116.73 ( 100.37 ) 133.95 ( 115.18 ) 117.15 ( 100.73 ) 132.71 ( 114.11 ) 119.28 ( 102.57 ) 131.56 ( 113.12 )
42.2 117.01 ( 100.61 ) 134.27 ( 115.45 ) 117.43 ( 100.97 ) 133.02 ( 114.38 ) 119.57 ( 102.81 ) 131.88 ( 113.39 )
42.3 117.29 ( 100.85 ) 134.59 ( 115.73 ) 117.70 ( 101.21 ) 133.34 ( 114.65 ) 119.85 ( 103.05 ) 132.19 ( 113.66 )
42.4 117.56 ( 101.09 ) 134.91 ( 116.00 ) 117.98 ( 101.45 ) 133.65 ( 114.92 ) 120.13 ( 103.30 ) 132.50 ( 113.93 )
42.5 117.84 ( 101.32 ) 135.23 ( 116.27 ) 118.26 ( 101.69 ) 133.97 ( 115.19 ) 120.42 ( 103.54 ) 132.81 ( 114.20 )
42.6 118.12 ( 101.56 ) 135.55 ( 116.55 ) 118.54 ( 101.93 ) 134.28 ( 115.46 ) 120.70 ( 103.78 ) 133.13 ( 114.47 )
42.7 118.40 ( 101.80 ) 135.86 ( 116.82 ) 118.82 ( 102.16 ) 134.60 ( 115.73 ) 120.98 ( 104.03 ) 133.44 ( 114.74 )
42.8 118.67 ( 102.04 ) 136.18 ( 117.10 ) 119.10 ( 102.40 ) 134.91 ( 116.00 ) 121.27 ( 104.27 ) 133.75 ( 115.00 )
42.9 118.95 ( 102.28 ) 136.50 ( 117.37 ) 119.37 ( 102.64 ) 135.23 ( 116.28 ) 121.55 ( 104.51 ) 134.06 ( 115.27 )
43.0 119.23 ( 102.52 ) 136.82 ( 117.64 ) 119.65 ( 102.88 ) 135.54 ( 116.55 ) 121.83 ( 104.76 ) 134.38 ( 115.54 )
43.1 119.50 ( 102.76 ) 137.14 ( 117.92 ) 119.93 ( 103.12 ) 135.86 ( 116.82 ) 122.12 ( 105.00 ) 134.69 ( 115.81 )
43.2 119.78 ( 102.99 ) 137.45 ( 118.19 ) 120.21 ( 103.36 ) 136.17 ( 117.09 ) 122.40 ( 105.25 ) 135.00 ( 116.08 )
43.3 120.06 ( 103.23 ) 137.77 ( 118.46 ) 120.49 ( 103.60 ) 136.49 ( 117.36 ) 122.68 ( 105.49 ) 135.31 ( 116.35 )
43.4 120.34 ( 103.47 ) 138.09 ( 118.74 ) 120.77 ( 103.84 ) 136.80 ( 117.63 ) 122.97 ( 105.73 ) 135.63 ( 116.62 )
43.5 120.61 ( 103.71 ) 138.41 ( 119.01 ) 121.04 ( 104.08 ) 137.12 ( 117.90 ) 123.25 ( 105.98 ) 135.94 ( 116.89 )
43.6 120.89 ( 103.95 ) 138.73 ( 119.28 ) 121.32 ( 104.32 ) 137.43 ( 118.17 ) 123.53 ( 106.22 ) 136.25 ( 117.15 )
43.7 121.17 ( 104.19 ) 139.05 ( 119.56 ) 121.60 ( 104.56 ) 137.75 ( 118.44 ) 123.82 ( 106.46 ) 136.56 ( 117.42 )
43.8 121.45 ( 104.42 ) 139.36 ( 119.83 ) 121.88 ( 104.80 ) 138.07 ( 118.71 ) 124.10 ( 106.71 ) 136.88 ( 117.69 )
43.9 121.72 ( 104.66 ) 139.68 ( 120.10 ) 122.16 ( 105.04 ) 138.38 ( 118.99 ) 124.38 ( 106.95 ) 137.19 ( 117.96 )
44.0 122.00 ( 104.90 ) 140.00 ( 120.38 ) 122.43 ( 105.27 ) 138.70 ( 119.26 ) 124.67 ( 107.19 ) 137.50 ( 118.23 )
44.1 122.03 ( 104.92 ) 140.02 ( 120.40 ) 122.71 ( 105.51 ) 139.01 ( 119.53 ) 124.95 ( 107.44 ) 137.81 ( 118.50 )
44.2 122.06 ( 104.95 ) 140.04 ( 120.41 ) 122.99 ( 105.75 ) 139.33 ( 119.80 ) 125.23 ( 107.68 ) 138.13 ( 118.77 )
44.3 122.08 ( 104.97 ) 140.06 ( 120.43 ) 123.27 ( 105.99 ) 139.64 ( 120.07 ) 125.52 ( 107.92 ) 138.44 ( 119.03 )
44.4 122.11 ( 105.00 ) 140.08 ( 120.45 ) 123.55 ( 106.23 ) 139.96 ( 120.34 ) 125.80 ( 108.17 ) 138.75 ( 119.30 )
44.5 122.14 ( 105.02 ) 140.11 ( 120.47 ) 123.83 ( 106.47 ) 140.27 ( 120.61 ) 126.08 ( 108.41 ) 139.06 ( 119.57 )
44.6 122.17 ( 105.04 ) 140.13 ( 120.49 ) 124.10 ( 106.71 ) 140.59 ( 120.88 ) 126.37 ( 108.66 ) 139.38 ( 119.84 )
44.7 122.19 ( 105.07 ) 140.15 ( 120.51 ) 124.38 ( 106.95 ) 140.90 ( 121.15 ) 126.65 ( 108.90 ) 139.69 ( 120.11 )
44.8 122.22 ( 105.09 ) 140.17 ( 120.52 ) 124.66 ( 107.19 ) 141.22 ( 121.43 ) 126.93 ( 109.14 ) 140.00 ( 120.38 )
44.9 122.25 ( 105.12 ) 140.19 ( 120.54 ) 124.94 ( 107.43 ) 141.53 ( 121.70 ) 127.22 ( 109.39 ) 140.31 ( 120.65 )
45.0 122.28 ( 105.14 ) 140.21 ( 120.56 ) 125.22 ( 107.67 ) 141.85 ( 121.97 ) 127.50 ( 109.63 ) 140.63 ( 120.92 )
45.1 122.31 ( 105.16 ) 140.23 ( 120.58 ) 125.50 ( 107.91 ) 142.16 ( 122.24 ) 127.78 ( 109.87 ) 140.94 ( 121.18 )
45.2 122.33 ( 105.19 ) 140.25 ( 120.60 ) 125.77 ( 108.15 ) 142.48 ( 122.51 ) 128.07 ( 110.12 ) 141.25 ( 121.45 )
45.3 122.36 ( 105.21 ) 140.28 ( 120.62 ) 126.05 ( 108.39 ) 142.79 ( 122.78 ) 128.35 ( 110.36 ) 141.56 ( 121.72 )
45.4 122.39 ( 105.23 ) 140.30 ( 120.63 ) 126.33 ( 108.62 ) 143.11 ( 123.05 ) 128.63 ( 110.60 ) 141.88 ( 121.99 )
45.5 122.42 ( 105.26 ) 140.32 ( 120.65 ) 126.61 ( 108.86 ) 143.42 ( 123.32 ) 128.92 ( 110.85 ) 142.19 ( 122.26 )
45.6 122.44 ( 105.28 ) 140.34 ( 120.67 ) 126.89 ( 109.10 ) 143.74 ( 123.59 ) 129.20 ( 111.09 ) 142.50 ( 122.53 )
45.7 122.47 ( 105.31 ) 140.36 ( 120.69 ) 127.17 ( 109.34 ) 144.05 ( 123.86 ) 129.48 ( 111.34 ) 142.81 ( 122.80 )
45.8 122.50 ( 105.33 ) 140.38 ( 120.71 ) 127.44 ( 109.58 ) 144.37 ( 124.14 ) 129.77 ( 111.58 ) 143.13 ( 123.07 )
45.9 122.53 ( 105.35 ) 140.40 ( 120.72 ) 127.72 ( 109.82 ) 144.68 ( 124.41 ) 130.05 ( 111.82 ) 143.44 ( 123.33 )

1-98 FAN-2209 201709


SELECTION DATA

Table 31. Outdoor Unit Capacity (JTOR440~480VAE(U,F,R)BS1) with Total Horsepower of Combined Indoor Unit (5)
Total Outdoor Unit Capacity: kW (×1000kcal/h)
RAS-44FSXNS
JTOR440VAE(U,F,R)BS1 RAS-46FSXNS
JTOR460VAE(U,F,R)BS1 RAS-48FSXNS
JTOR480VAE(U,F,R)BS1
Cooling Heating Cooling Heating Cooling Heating
46.0 122.55 ( 105.38 ) 140.42 ( 120.74 ) 128.00 ( 110.06 ) 145.00 ( 124.68 ) 130.33 ( 112.07 ) 143.75 ( 123.60 )
46.1 122.58 ( 105.40 ) 140.45 ( 120.76 ) 128.03 ( 110.08 ) 145.02 ( 124.70 ) 130.62 ( 112.31 ) 144.06 ( 123.87 )
46.2 122.61 ( 105.43 ) 140.47 ( 120.78 ) 128.06 ( 110.11 ) 145.04 ( 124.71 ) 130.90 ( 112.55 ) 144.38 ( 124.14 )
46.3 122.64 ( 105.45 ) 140.49 ( 120.80 ) 128.08 ( 110.13 ) 145.06 ( 124.73 ) 131.18 ( 112.80 ) 144.69 ( 124.41 )
46.4 122.67 ( 105.47 ) 140.51 ( 120.82 ) 128.11 ( 110.16 ) 145.08 ( 124.75 ) 131.47 ( 113.04 ) 145.00 ( 124.68 )
46.5 122.69 ( 105.50 ) 140.53 ( 120.83 ) 128.14 ( 110.18 ) 145.11 ( 124.77 ) 131.75 ( 113.28 ) 145.31 ( 124.95 )
46.6 122.72 ( 105.52 ) 140.55 ( 120.85 ) 128.17 ( 110.20 ) 145.13 ( 124.79 ) 132.03 ( 113.53 ) 145.63 ( 125.21 )
46.7 122.75 ( 105.54 ) 140.57 ( 120.87 ) 128.19 ( 110.23 ) 145.15 ( 124.80 ) 132.32 ( 113.77 ) 145.94 ( 125.48 )
46.8 122.78 ( 105.57 ) 140.59 ( 120.89 ) 128.22 ( 110.25 ) 145.17 ( 124.82 ) 132.60 ( 114.02 ) 146.25 ( 125.75 )
46.9 122.80 ( 105.59 ) 140.62 ( 120.91 ) 128.25 ( 110.28 ) 145.19 ( 124.84 ) 132.88 ( 114.26 ) 146.56 ( 126.02 )
47.0 122.83 ( 105.62 ) 140.64 ( 120.93 ) 128.28 ( 110.30 ) 145.21 ( 124.86 ) 133.17 ( 114.50 ) 146.88 ( 126.29 )
47.1 122.86 ( 105.64 ) 140.66 ( 120.94 ) 128.31 ( 110.32 ) 145.23 ( 124.88 ) 133.45 ( 114.75 ) 147.19 ( 126.56 )
47.2 122.89 ( 105.66 ) 140.68 ( 120.96 ) 128.33 ( 110.35 ) 145.25 ( 124.89 ) 133.73 ( 114.99 ) 147.50 ( 126.83 )
47.3 122.92 ( 105.69 ) 140.70 ( 120.98 ) 128.36 ( 110.37 ) 145.27 ( 124.91 ) 134.02 ( 115.23 ) 147.81 ( 127.10 )
47.4 122.94 ( 105.71 ) 140.72 ( 121.00 ) 128.39 ( 110.40 ) 145.29 ( 124.93 ) 134.30 ( 115.48 ) 148.13 ( 127.36 )
47.5 122.97 ( 105.74 ) 140.74 ( 121.02 ) 128.42 ( 110.42 ) 145.32 ( 124.95 ) 134.58 ( 115.72 ) 148.44 ( 127.63 )
47.6 123.00 ( 105.76 ) 140.76 ( 121.03 ) 128.45 ( 110.44 ) 145.34 ( 124.97 ) 134.87 ( 115.96 ) 148.75 ( 127.90 )
47.7 123.03 ( 105.78 ) 140.78 ( 121.05 ) 128.47 ( 110.47 ) 145.36 ( 124.98 ) 135.15 ( 116.21 ) 149.06 ( 128.17 )
47.8 123.05 ( 105.81 ) 140.81 ( 121.07 ) 128.50 ( 110.49 ) 145.38 ( 125.00 ) 135.43 ( 116.45 ) 149.38 ( 128.44 )
47.9 123.08 ( 105.83 ) 140.83 ( 121.09 ) 128.53 ( 110.51 ) 145.40 ( 125.02 ) 135.72 ( 116.70 ) 149.69 ( 128.71 )
48.0 123.11 ( 105.85 ) 140.85 ( 121.11 ) 128.56 ( 110.54 ) 145.42 ( 125.04 ) 136.00 ( 116.94 ) 150.00 ( 128.98 )
48.1 123.14 ( 105.88 ) 140.87 ( 121.13 ) 128.58 ( 110.56 ) 145.44 ( 125.06 ) 136.03 ( 116.96 ) 150.02 ( 128.99 )
48.2 123.16 ( 105.90 ) 140.89 ( 121.14 ) 128.61 ( 110.59 ) 145.46 ( 125.08 ) 136.06 ( 116.99 ) 150.04 ( 129.01 )
48.3 123.19 ( 105.93 ) 140.91 ( 121.16 ) 128.64 ( 110.61 ) 145.48 ( 125.09 ) 136.09 ( 117.01 ) 150.06 ( 129.03 )
48.4 123.22 ( 105.95 ) 140.93 ( 121.18 ) 128.67 ( 110.63 ) 145.50 ( 125.11 ) 136.11 ( 117.04 ) 150.08 ( 129.05 )
48.5 123.25 ( 105.97 ) 140.95 ( 121.20 ) 128.70 ( 110.66 ) 145.53 ( 125.13 ) 136.14 ( 117.06 ) 150.10 ( 129.07 )
48.6 123.28 ( 106.00 ) 140.98 ( 121.22 ) 128.72 ( 110.68 ) 145.55 ( 125.15 ) 136.17 ( 117.09 ) 150.13 ( 129.08 )
48.7 123.30 ( 106.02 ) 141.00 ( 121.24 ) 128.75 ( 110.71 ) 145.57 ( 125.17 ) 136.20 ( 117.11 ) 150.15 ( 129.10 )
48.8 123.33 ( 106.05 ) 141.02 ( 121.25 ) 128.78 ( 110.73 ) 145.59 ( 125.18 ) 136.23 ( 117.13 ) 150.17 ( 129.12 )
48.9 123.36 ( 106.07 ) 141.04 ( 121.27 ) 128.81 ( 110.75 ) 145.61 ( 125.20 ) 136.26 ( 117.16 ) 150.19 ( 129.14 )
49.0 123.39 ( 106.09 ) 141.06 ( 121.29 ) 128.83 ( 110.78 ) 145.63 ( 125.22 ) 136.28 ( 117.18 ) 150.21 ( 129.16 )
49.1 123.41 ( 106.12 ) 141.08 ( 121.31 ) 128.86 ( 110.80 ) 145.65 ( 125.24 ) 136.31 ( 117.21 ) 150.23 ( 129.17 )
49.2 123.44 ( 106.14 ) 141.10 ( 121.33 ) 128.89 ( 110.83 ) 145.67 ( 125.26 ) 136.34 ( 117.23 ) 150.25 ( 129.19 )
49.3 123.47 ( 106.16 ) 141.12 ( 121.35 ) 128.92 ( 110.85 ) 145.69 ( 125.27 ) 136.37 ( 117.26 ) 150.27 ( 129.21 )
49.4 123.50 ( 106.19 ) 141.15 ( 121.36 ) 128.95 ( 110.87 ) 145.71 ( 125.29 ) 136.40 ( 117.28 ) 150.29 ( 129.23 )
49.5 123.53 ( 106.21 ) 141.17 ( 121.38 ) 128.97 ( 110.90 ) 145.74 ( 125.31 ) 136.43 ( 117.30 ) 150.31 ( 129.25 )
49.6 123.55 ( 106.24 ) 141.19 ( 121.40 ) 129.00 ( 110.92 ) 145.76 ( 125.33 ) 136.45 ( 117.33 ) 150.33 ( 129.26 )
49.7 123.58 ( 106.26 ) 141.21 ( 121.42 ) 129.03 ( 110.95 ) 145.78 ( 125.35 ) 136.48 ( 117.35 ) 150.35 ( 129.28 )
49.8 123.61 ( 106.28 ) 141.23 ( 121.44 ) 129.06 ( 110.97 ) 145.80 ( 125.36 ) 136.51 ( 117.38 ) 150.38 ( 129.30 )
49.9 123.64 ( 106.31 ) 141.25 ( 121.45 ) 129.09 ( 110.99 ) 145.82 ( 125.38 ) 136.54 ( 117.40 ) 150.40 ( 129.32 )
50.0 123.66 ( 106.33 ) 141.27 ( 121.47 ) 129.11 ( 111.02 ) 145.84 ( 125.40 ) 136.57 ( 117.43 ) 150.42 ( 129.34 )
50.1 123.69 ( 106.36 ) 141.29 ( 121.49 ) 129.14 ( 111.04 ) 145.86 ( 125.42 ) 136.60 ( 117.45 ) 150.44 ( 129.35 )
50.2 123.72 ( 106.38 ) 141.32 ( 121.51 ) 129.17 ( 111.07 ) 145.88 ( 125.44 ) 136.62 ( 117.47 ) 150.46 ( 129.37 )
50.3 123.75 ( 106.40 ) 141.34 ( 121.53 ) 129.20 ( 111.09 ) 145.90 ( 125.45 ) 136.65 ( 117.50 ) 150.48 ( 129.39 )
50.4 123.77 ( 106.43 ) 141.36 ( 121.55 ) 129.22 ( 111.11 ) 145.92 ( 125.47 ) 136.68 ( 117.52 ) 150.50 ( 129.41 )
50.5 123.80 ( 106.45 ) 141.38 ( 121.56 ) 129.25 ( 111.14 ) 145.95 ( 125.49 ) 136.71 ( 117.55 ) 150.52 ( 129.42 )
50.6 123.83 ( 106.47 ) 141.40 ( 121.58 ) 129.28 ( 111.16 ) 145.97 ( 125.51 ) 136.74 ( 117.57 ) 150.54 ( 129.44 )
50.7 123.86 ( 106.50 ) 141.42 ( 121.60 ) 129.31 ( 111.18 ) 145.99 ( 125.53 ) 136.77 ( 117.60 ) 150.56 ( 129.46 )
50.8 123.89 ( 106.52 ) 141.44 ( 121.62 ) 129.34 ( 111.21 ) 146.01 ( 125.54 ) 136.79 ( 117.62 ) 150.58 ( 129.48 )
50.9 123.91 ( 106.55 ) 141.46 ( 121.64 ) 129.36 ( 111.23 ) 146.03 ( 125.56 ) 136.82 ( 117.65 ) 150.60 ( 129.50 )
51.0 123.94 ( 106.57 ) 141.48 ( 121.66 ) 129.39 ( 111.26 ) 146.05 ( 125.58 ) 136.85 ( 117.67 ) 150.63 ( 129.51 )
51.1 123.97 ( 106.59 ) 141.51 ( 121.67 ) 129.42 ( 111.28 ) 146.07 ( 125.60 ) 136.88 ( 117.69 ) 150.65 ( 129.53 )
51.2 124.00 ( 106.62 ) 141.53 ( 121.69 ) 129.45 ( 111.30 ) 146.09 ( 125.62 ) 136.91 ( 117.72 ) 150.67 ( 129.55 )
51.3 124.02 ( 106.64 ) 141.55 ( 121.71 ) 129.47 ( 111.33 ) 146.11 ( 125.64 ) 136.94 ( 117.74 ) 150.69 ( 129.57 )
51.4 124.05 ( 106.67 ) 141.57 ( 121.73 ) 129.50 ( 111.35 ) 146.13 ( 125.65 ) 136.96 ( 117.77 ) 150.71 ( 129.59 )
51.5 124.08 ( 106.69 ) 141.59 ( 121.75 ) 129.53 ( 111.38 ) 146.16 ( 125.67 ) 136.99 ( 117.79 ) 150.73 ( 129.60 )
51.6 124.11 ( 106.71 ) 141.61 ( 121.76 ) 129.56 ( 111.40 ) 146.18 ( 125.69 ) 137.02 ( 117.82 ) 150.75 ( 129.62 )
51.7 124.14 ( 106.74 ) 141.63 ( 121.78 ) 129.59 ( 111.42 ) 146.20 ( 125.71 ) 137.05 ( 117.84 ) 150.77 ( 129.64 )
51.8 124.16 ( 106.76 ) 141.65 ( 121.80 ) 129.61 ( 111.45 ) 146.22 ( 125.73 ) 137.08 ( 117.86 ) 150.79 ( 129.66 )
51.9 124.19 ( 106.78 ) 141.68 ( 121.82 ) 129.64 ( 111.47 ) 146.24 ( 125.74 ) 137.11 ( 117.89 ) 150.81 ( 129.68 )

FAN-2209 201709 1-99


SELECTION DATA

Table 32. Outdoor Unit Capacity (JTOR440~480VAE(U,F,R)BS1) with Total Horsepower of Combined Indoor Unit (6)
Total Outdoor Unit Capacity: kW (×1000kcal/h)
RAS-44FSXNS
JTOR440VAE(U,F,R)BS1 RAS-46FSXNS
JTOR460VAE(U,F,R)BS1 RAS-48FSXNS
JTOR480VAE(U,F,R)BS1
Cooling Heating Cooling Heating Cooling Heating
52.0 124.22 ( 106.81 ) 141.70 ( 121.84 ) 129.67 ( 111.50 ) 146.26 ( 125.76 ) 137.13 ( 117.91 ) 150.83 ( 129.69 )
52.1 124.25 ( 106.83 ) 141.72 ( 121.86 ) 129.70 ( 111.52 ) 146.28 ( 125.78 ) 137.16 ( 117.94 ) 150.85 ( 129.71 )
52.2 124.27 ( 106.86 ) 141.74 ( 121.87 ) 129.73 ( 111.54 ) 146.30 ( 125.80 ) 137.19 ( 117.96 ) 150.88 ( 129.73 )
52.3 124.30 ( 106.88 ) 141.76 ( 121.89 ) 129.75 ( 111.57 ) 146.32 ( 125.82 ) 137.22 ( 117.99 ) 150.90 ( 129.75 )
52.4 124.33 ( 106.90 ) 141.78 ( 121.91 ) 129.78 ( 111.59 ) 146.34 ( 125.83 ) 137.25 ( 118.01 ) 150.92 ( 129.76 )
52.5 124.36 ( 106.93 ) 141.80 ( 121.93 ) 129.81 ( 111.62 ) 146.37 ( 125.85 ) 137.28 ( 118.04 ) 150.94 ( 129.78 )
52.6 124.38 ( 106.95 ) 141.82 ( 121.95 ) 129.84 ( 111.64 ) 146.39 ( 125.87 ) 137.30 ( 118.06 ) 150.96 ( 129.80 )
52.7 124.41 ( 106.98 ) 141.85 ( 121.97 ) 129.86 ( 111.66 ) 146.41 ( 125.89 ) 137.33 ( 118.08 ) 150.98 ( 129.82 )
52.8 124.44 ( 107.00 ) 141.87 ( 121.98 ) 129.89 ( 111.69 ) 146.43 ( 125.91 ) 137.36 ( 118.11 ) 151.00 ( 129.84 )
52.9 124.47 ( 107.02 ) 141.89 ( 122.00 ) 129.92 ( 111.71 ) 146.45 ( 125.92 ) 137.39 ( 118.13 ) 151.02 ( 129.85 )
53.0 124.50 ( 107.05 ) 141.91 ( 122.02 ) 129.95 ( 111.74 ) 146.47 ( 125.94 ) 137.42 ( 118.16 ) 151.04 ( 129.87 )
53.1 124.52 ( 107.07 ) 141.93 ( 122.04 ) 129.98 ( 111.76 ) 146.49 ( 125.96 ) 137.45 ( 118.18 ) 151.06 ( 129.89 )
53.2 124.55 ( 107.09 ) 141.95 ( 122.06 ) 130.00 ( 111.78 ) 146.51 ( 125.98 ) 137.47 ( 118.21 ) 151.08 ( 129.91 )
53.3 124.58 ( 107.12 ) 141.97 ( 122.07 ) 130.03 ( 111.81 ) 146.53 ( 126.00 ) 137.50 ( 118.23 ) 151.10 ( 129.93 )
53.4 124.61 ( 107.14 ) 141.99 ( 122.09 ) 130.06 ( 111.83 ) 146.56 ( 126.01 ) 137.53 ( 118.25 ) 151.13 ( 129.94 )
53.5 124.63 ( 107.17 ) 142.02 ( 122.11 ) 130.09 ( 111.85 ) 146.58 ( 126.03 ) 137.56 ( 118.28 ) 151.15 ( 129.96 )
53.6 124.66 ( 107.19 ) 142.04 ( 122.13 ) 130.11 ( 111.88 ) 146.60 ( 126.05 ) 137.59 ( 118.30 ) 151.17 ( 129.98 )
53.7 124.69 ( 107.21 ) 142.06 ( 122.15 ) 130.14 ( 111.90 ) 146.62 ( 126.07 ) 137.62 ( 118.33 ) 151.19 ( 130.00 )
53.8 124.72 ( 107.24 ) 142.08 ( 122.17 ) 130.17 ( 111.93 ) 146.64 ( 126.09 ) 137.64 ( 118.35 ) 151.21 ( 130.02 )
53.9 124.75 ( 107.26 ) 142.10 ( 122.18 ) 130.20 ( 111.95 ) 146.66 ( 126.11 ) 137.67 ( 118.38 ) 151.23 ( 130.03 )
54.0 124.77 ( 107.29 ) 142.12 ( 122.20 ) 130.23 ( 111.97 ) 146.68 ( 126.12 ) 137.70 ( 118.40 ) 151.25 ( 130.05 )
54.1 124.80 ( 107.31 ) 142.14 ( 122.22 ) 130.25 ( 112.00 ) 146.70 ( 126.14 ) 137.73 ( 118.43 ) 151.27 ( 130.07 )
54.2 124.83 ( 107.33 ) 142.16 ( 122.24 ) 130.28 ( 112.02 ) 146.72 ( 126.16 ) 137.76 ( 118.45 ) 151.29 ( 130.09 )
54.3 124.86 ( 107.36 ) 142.18 ( 122.26 ) 130.31 ( 112.05 ) 146.74 ( 126.18 ) 137.79 ( 118.47 ) 151.31 ( 130.11 )
54.4 124.88 ( 107.38 ) 142.21 ( 122.28 ) 130.34 ( 112.07 ) 146.77 ( 126.20 ) 137.81 ( 118.50 ) 151.33 ( 130.12 )
54.5 124.91 ( 107.40 ) 142.23 ( 122.29 ) 130.37 ( 112.09 ) 146.79 ( 126.21 ) 137.84 ( 118.52 ) 151.35 ( 130.14 )
54.6 124.94 ( 107.43 ) 142.25 ( 122.31 ) 130.39 ( 112.12 ) 146.81 ( 126.23 ) 137.87 ( 118.55 ) 151.38 ( 130.16 )
54.7 124.97 ( 107.45 ) 142.27 ( 122.33 ) 130.42 ( 112.14 ) 146.83 ( 126.25 ) 137.90 ( 118.57 ) 151.40 ( 130.18 )
54.8 124.99 ( 107.48 ) 142.29 ( 122.35 ) 130.45 ( 112.17 ) 146.85 ( 126.27 ) 137.93 ( 118.60 ) 151.42 ( 130.19 )
54.9 125.02 ( 107.50 ) 142.31 ( 122.37 ) 130.48 ( 112.19 ) 146.87 ( 126.29 ) 137.96 ( 118.62 ) 151.44 ( 130.21 )
55.0 125.05 ( 107.52 ) 142.33 ( 122.38 ) 130.50 ( 112.21 ) 146.89 ( 126.30 ) 137.98 ( 118.64 ) 151.46 ( 130.23 )
55.1 125.08 ( 107.55 ) 142.35 ( 122.40 ) 130.53 ( 112.24 ) 146.91 ( 126.32 ) 138.01 ( 118.67 ) 151.48 ( 130.25 )
55.2 125.11 ( 107.57 ) 142.38 ( 122.42 ) 130.56 ( 112.26 ) 146.93 ( 126.34 ) 138.04 ( 118.69 ) 151.50 ( 130.27 )
55.3 125.13 ( 107.60 ) 142.40 ( 122.44 ) 130.59 ( 112.29 ) 146.95 ( 126.36 ) 138.07 ( 118.72 ) 151.52 ( 130.28 )
55.4 125.16 ( 107.62 ) 142.42 ( 122.46 ) 130.62 ( 112.31 ) 146.98 ( 126.38 ) 138.10 ( 118.74 ) 151.54 ( 130.30 )
55.5 125.19 ( 107.64 ) 142.44 ( 122.48 ) 130.64 ( 112.33 ) 147.00 ( 126.39 ) 138.13 ( 118.77 ) 151.56 ( 130.32 )
55.6 125.22 ( 107.67 ) 142.46 ( 122.49 ) 130.67 ( 112.36 ) 147.02 ( 126.41 ) 138.15 ( 118.79 ) 151.58 ( 130.34 )
55.7 125.24 ( 107.69 ) 142.48 ( 122.51 ) 130.70 ( 112.38 ) 147.04 ( 126.43 ) 138.18 ( 118.81 ) 151.60 ( 130.36 )
55.8 125.27 ( 107.71 ) 142.50 ( 122.53 ) 130.73 ( 112.40 ) 147.06 ( 126.45 ) 138.21 ( 118.84 ) 151.63 ( 130.37 )
55.9 125.30 ( 107.74 ) 142.52 ( 122.55 ) 130.75 ( 112.43 ) 147.08 ( 126.47 ) 138.24 ( 118.86 ) 151.65 ( 130.39 )
56.0 125.33 ( 107.76 ) 142.55 ( 122.57 ) 130.78 ( 112.45 ) 147.10 ( 126.48 ) 138.27 ( 118.89 ) 151.67 ( 130.41 )
56.1 125.36 ( 107.79 ) 142.57 ( 122.59 ) 130.81 ( 112.48 ) 147.12 ( 126.50 ) 138.30 ( 118.91 ) 151.69 ( 130.43 )
56.2 125.38 ( 107.81 ) 142.59 ( 122.60 ) 130.84 ( 112.50 ) 147.14 ( 126.52 ) 138.32 ( 118.94 ) 151.71 ( 130.45 )
56.3 125.41 ( 107.83 ) 142.61 ( 122.62 ) 130.87 ( 112.52 ) 147.16 ( 126.54 ) 138.35 ( 118.96 ) 151.73 ( 130.46 )
56.4 125.44 ( 107.86 ) 142.63 ( 122.64 ) 130.89 ( 112.55 ) 147.19 ( 126.56 ) 138.38 ( 118.99 ) 151.75 ( 130.48 )
56.5 125.47 ( 107.88 ) 142.65 ( 122.66 ) 130.92 ( 112.57 ) 147.21 ( 126.57 ) 138.41 ( 119.01 ) 151.77 ( 130.50 )
56.6 125.49 ( 107.91 ) 142.67 ( 122.68 ) 130.95 ( 112.60 ) 147.23 ( 126.59 ) 138.44 ( 119.03 ) 151.79 ( 130.52 )
56.7 125.52 ( 107.93 ) 142.69 ( 122.69 ) 130.98 ( 112.62 ) 147.25 ( 126.61 ) 138.47 ( 119.06 ) 151.81 ( 130.54 )
56.8 125.55 ( 107.95 ) 142.72 ( 122.71 ) 131.01 ( 112.64 ) 147.27 ( 126.63 ) 138.49 ( 119.08 ) 151.83 ( 130.55 )
56.9 125.58 ( 107.98 ) 142.74 ( 122.73 ) 131.03 ( 112.67 ) 147.29 ( 126.65 ) 138.52 ( 119.11 ) 151.85 ( 130.57 )
57.0 125.60 ( 108.00 ) 142.76 ( 122.75 ) 131.06 ( 112.69 ) 147.31 ( 126.67 ) 138.55 ( 119.13 ) 151.88 ( 130.59 )
57.1 125.63 ( 108.02 ) 142.78 ( 122.77 ) 131.09 ( 112.72 ) 147.33 ( 126.68 ) 138.58 ( 119.16 ) 151.90 ( 130.61 )
57.2 125.66 ( 108.05 ) 142.80 ( 122.79 ) 131.12 ( 112.74 ) 147.35 ( 126.70 ) 138.61 ( 119.18 ) 151.92 ( 130.62 )
57.3 131.14 ( 112.76 ) 147.37 ( 126.72 ) 138.64 ( 119.20 ) 151.94 ( 130.64 )
57.4 131.17 ( 112.79 ) 147.40 ( 126.74 ) 138.66 ( 119.23 ) 151.96 ( 130.66 )
57.5 131.20 ( 112.81 ) 147.42 ( 126.76 ) 138.69 ( 119.25 ) 151.98 ( 130.68 )
57.6 _ 131.23 ( 112.84 ) 147.44 ( 126.77 ) 138.72 ( 119.28 ) 152.00 ( 130.70 )
57.7 131.26 ( 112.86 ) 147.46 ( 126.79 ) 138.75 ( 119.30 ) 152.02 ( 130.71 )
57.8 131.28 ( 112.88 ) 147.48 ( 126.81 ) 138.78 ( 119.33 ) 152.04 ( 130.73 )
57.9 131.31 ( 112.91 ) 147.50 ( 126.83 ) 138.81 ( 119.35 ) 152.06 ( 130.75 )

1-100 FAN-2209 201709


SELECTION DATA

Table 33. Outdoor Unit Capacity (JTOR440~480VAE(U,F,R)BS1) with Total Horsepower of Combined Indoor Unit (7)
Total Outdoor Unit Capacity: kW (×1000kcal/h)
RAS-44FSXNS
JTOR440VAE(U,F,R)BS1 RAS-46FSXNS
JTOR460VAE(U,F,R)BS1 RAS-48FSXNS
JTOR480VAE(U,F,R)BS1
Cooling Heating Cooling Heating Cooling Heating
58.0 131.34 ( 112.93 ) 147.52 ( 126.85 ) 138.83 ( 119.38 ) 152.08 ( 130.77 )
58.1 131.37 ( 112.96 ) 147.54 ( 126.86 ) 138.86 ( 119.40 ) 152.10 ( 130.79 )
58.2 131.39 ( 112.98 ) 147.56 ( 126.88 ) 138.89 ( 119.42 ) 152.13 ( 130.80 )
58.3 131.42 ( 113.00 ) 147.58 ( 126.90 ) 138.92 ( 119.45 ) 152.15 ( 130.82 )
58.4 131.45 ( 113.03 ) 147.61 ( 126.92 ) 138.95 ( 119.47 ) 152.17 ( 130.84 )
58.5 131.48 ( 113.05 ) 147.63 ( 126.94 ) 138.98 ( 119.50 ) 152.19 ( 130.86 )
58.6 131.51 ( 113.07 ) 147.65 ( 126.95 ) 139.00 ( 119.52 ) 152.21 ( 130.88 )
58.7 131.53 ( 113.10 ) 147.67 ( 126.97 ) 139.03 ( 119.55 ) 152.23 ( 130.89 )
58.8 131.56 ( 113.12 ) 147.69 ( 126.99 ) 139.06 ( 119.57 ) 152.25 ( 130.91 )
58.9 131.59 ( 113.15 ) 147.71 ( 127.01 ) 139.09 ( 119.59 ) 152.27 ( 130.93 )
59.0 131.62 ( 113.17 ) 147.73 ( 127.03 ) 139.12 ( 119.62 ) 152.29 ( 130.95 )
59.1 131.65 ( 113.19 ) 147.75 ( 127.04 ) 139.15 ( 119.64 ) 152.31 ( 130.97 )
59.2 131.67 ( 113.22 ) 147.77 ( 127.06 ) 139.17 ( 119.67 ) 152.33 ( 130.98 )
59.3 131.70 ( 113.24 ) 147.79 ( 127.08 ) 139.20 ( 119.69 ) 152.35 ( 131.00 )
59.4 131.73 ( 113.27 ) 147.82 ( 127.10 ) 139.23 ( 119.72 ) 152.38 ( 131.02 )
59.5 131.76 ( 113.29 ) 147.84 ( 127.12 ) 139.26 ( 119.74 ) 152.40 ( 131.04 )
59.6 131.78 ( 113.31 ) 147.86 ( 127.13 ) 139.29 ( 119.76 ) 152.42 ( 131.05 )
59.7 131.81 ( 113.34 ) 147.88 ( 127.15 ) 139.32 ( 119.79 ) 152.44 ( 131.07 )
59.8 131.84 ( 113.36 ) 147.90 ( 127.17 ) 139.34 ( 119.81 ) 152.46 ( 131.09 )
59.9 139.37 ( 119.84 ) 152.48 ( 131.11 )
60.0 139.40 ( 119.86 ) 152.50 ( 131.13 )
60.1 139.43 ( 119.89 ) 152.52 ( 131.14 )
60.2 _ 139.46 ( 119.91 ) 152.54 ( 131.16 )
60.3 139.49 ( 119.94 ) 152.56 ( 131.18 )
60.4 139.51 ( 119.96 ) 152.58 ( 131.20 )
60.5 139.54 ( 119.98 ) 152.60 ( 131.22 )
60.6 139.57 ( 120.01 ) 152.63 ( 131.23 )
60.7 139.60 ( 120.03 ) 152.65 ( 131.25 )
60.8 139.63 ( 120.06 ) 152.67 ( 131.27 )
60.9 139.66 ( 120.08 ) 152.69 ( 131.29 )
61.0 139.68 ( 120.11 ) 152.71 ( 131.31 )
61.1 139.71 ( 120.13 ) 152.73 ( 131.32 )
_
61.2 139.74 ( 120.15 ) 152.75 ( 131.34 )
61.3 139.77 ( 120.18 ) 152.77 ( 131.36 )
61.4 139.80 ( 120.20 ) 152.79 ( 131.38 )
61.5 139.83 ( 120.23 ) 152.81 ( 131.40 )
61.6 139.85 ( 120.25 ) 152.83 ( 131.41 )
61.7 139.88 ( 120.28 ) 152.85 ( 131.43 )
61.8 139.91 ( 120.30 ) 152.88 ( 131.45 )
61.9 139.94 ( 120.33 ) 152.90 ( 131.47 )
62.0 139.97 ( 120.35 ) 152.92 ( 131.48 )
62.1 140.00 ( 120.37 ) 152.94 ( 131.50 )
62.2 140.02 ( 120.40 ) 152.96 ( 131.52 )
62.3 140.05 ( 120.42 ) 152.98 ( 131.54 )
62.4 140.08 ( 120.45 ) 153.00 ( 131.56 )

FAN-2209 201709 1-101


SELECTION DATA

Table 34. Outdoor Unit Capacity (JTOR500~540VAE(U,F,R)BS1) with Total Horsepower of Combined Indoor Unit (1)
Total Outdoor Unit Capacity: kW (×1000kcal/h)
RAS-50FSXNS
JTOR500VAE(U,F,R)BS1 RAS-52FSXNS
JTOR520VAE(U,F,R)BS1 RAS-54FSXNS
JTOR540VAE(U,F,R)BS1
Cooling Heating Cooling Heating Cooling Heating
25.0 70.00 ( 60.19 ) 77.50 ( 66.64 )
25.1 70.28 ( 60.43 ) 77.81 ( 66.90 )
25.2 70.56 ( 60.67 ) 78.12 ( 67.17 )
25.3 70.84 ( 60.91 ) 78.43 ( 67.44 )
25.4 71.12 ( 61.15 ) 78.74 ( 67.70 )
_
25.5 71.40 ( 61.39 ) 79.05 ( 67.97 )
25.6 71.68 ( 61.63 ) 79.36 ( 68.24 )
25.7 71.96 ( 61.87 ) 79.67 ( 68.50 )
25.8 72.24 ( 62.12 ) 79.98 ( 68.77 )
25.9 72.52 ( 62.36 ) 80.29 ( 69.04 )
_
26.0 72.80 ( 62.60 ) 80.60 ( 69.30 ) 72.50 ( 62.34 ) 80.00 ( 68.79 )
26.1 73.08 ( 62.84 ) 80.91 ( 69.57 ) 72.78 ( 62.58 ) 80.31 ( 69.05 )
26.2 73.36 ( 63.08 ) 81.22 ( 69.84 ) 73.06 ( 62.82 ) 80.62 ( 69.32 )
26.3 73.64 ( 63.32 ) 81.53 ( 70.10 ) 73.34 ( 63.06 ) 80.92 ( 69.58 )
26.4 73.92 ( 63.56 ) 81.84 ( 70.37 ) 73.62 ( 63.30 ) 81.23 ( 69.85 )
26.5 74.20 ( 63.80 ) 82.15 ( 70.64 ) 73.89 ( 63.54 ) 81.54 ( 70.11 )
26.6 74.48 ( 64.04 ) 82.46 ( 70.90 ) 74.17 ( 63.78 ) 81.85 ( 70.38 )
26.7 74.76 ( 64.28 ) 82.77 ( 71.17 ) 74.45 ( 64.02 ) 82.15 ( 70.64 )
26.8 75.04 ( 64.52 ) 83.08 ( 71.44 ) 74.73 ( 64.26 ) 82.46 ( 70.90 )
26.9 75.32 ( 64.76 ) 83.39 ( 71.70 ) 75.01 ( 64.50 ) 82.77 ( 71.17 )
27.0 75.60 ( 65.00 ) 83.70 ( 71.97 ) 75.29 ( 64.74 ) 83.08 ( 71.43 ) 75.00 ( 64.49 ) 82.50 ( 70.94 )
27.1 75.88 ( 65.25 ) 84.01 ( 72.24 ) 75.57 ( 64.98 ) 83.38 ( 71.70 ) 75.28 ( 64.73 ) 82.81 ( 71.20 )
27.2 76.16 ( 65.49 ) 84.32 ( 72.50 ) 75.85 ( 65.22 ) 83.69 ( 71.96 ) 75.56 ( 64.97 ) 83.11 ( 71.46 )
27.3 76.44 ( 65.73 ) 84.63 ( 72.77 ) 76.12 ( 65.46 ) 84.00 ( 72.23 ) 75.83 ( 65.20 ) 83.42 ( 71.73 )
27.4 76.72 ( 65.97 ) 84.94 ( 73.04 ) 76.40 ( 65.70 ) 84.31 ( 72.49 ) 76.11 ( 65.44 ) 83.72 ( 71.99 )
27.5 77.00 ( 66.21 ) 85.25 ( 73.30 ) 76.68 ( 65.94 ) 84.62 ( 72.76 ) 76.39 ( 65.68 ) 84.03 ( 72.25 )
27.6 77.28 ( 66.45 ) 85.56 ( 73.57 ) 76.96 ( 66.18 ) 84.92 ( 73.02 ) 76.67 ( 65.92 ) 84.33 ( 72.51 )
27.7 77.56 ( 66.69 ) 85.87 ( 73.83 ) 77.24 ( 66.41 ) 85.23 ( 73.29 ) 76.94 ( 66.16 ) 84.64 ( 72.78 )
27.8 77.84 ( 66.93 ) 86.18 ( 74.10 ) 77.52 ( 66.65 ) 85.54 ( 73.55 ) 77.22 ( 66.40 ) 84.94 ( 73.04 )
27.9 78.12 ( 67.17 ) 86.49 ( 74.37 ) 77.80 ( 66.89 ) 85.85 ( 73.81 ) 77.50 ( 66.64 ) 85.25 ( 73.30 )
28.0 78.40 ( 67.41 ) 86.80 ( 74.63 ) 78.08 ( 67.13 ) 86.15 ( 74.08 ) 77.78 ( 66.88 ) 85.56 ( 73.56 )
28.1 78.68 ( 67.65 ) 87.11 ( 74.90 ) 78.36 ( 67.37 ) 86.46 ( 74.34 ) 78.06 ( 67.12 ) 85.86 ( 73.83 )
28.2 78.96 ( 67.89 ) 87.42 ( 75.17 ) 78.63 ( 67.61 ) 86.77 ( 74.61 ) 78.33 ( 67.35 ) 86.17 ( 74.09 )
28.3 79.24 ( 68.13 ) 87.73 ( 75.43 ) 78.91 ( 67.85 ) 87.08 ( 74.87 ) 78.61 ( 67.59 ) 86.47 ( 74.35 )
28.4 79.52 ( 68.37 ) 88.04 ( 75.70 ) 79.19 ( 68.09 ) 87.38 ( 75.14 ) 78.89 ( 67.83 ) 86.78 ( 74.62 )
28.5 79.80 ( 68.62 ) 88.35 ( 75.97 ) 79.47 ( 68.33 ) 87.69 ( 75.40 ) 79.17 ( 68.07 ) 87.08 ( 74.88 )
28.6 80.08 ( 68.86 ) 88.66 ( 76.23 ) 79.75 ( 68.57 ) 88.00 ( 75.67 ) 79.44 ( 68.31 ) 87.39 ( 75.14 )
28.7 80.36 ( 69.10 ) 88.97 ( 76.50 ) 80.03 ( 68.81 ) 88.31 ( 75.93 ) 79.72 ( 68.55 ) 87.69 ( 75.40 )
28.8 80.64 ( 69.34 ) 89.28 ( 76.77 ) 80.31 ( 69.05 ) 88.62 ( 76.20 ) 80.00 ( 68.79 ) 88.00 ( 75.67 )
28.9 80.92 ( 69.58 ) 89.59 ( 77.03 ) 80.59 ( 69.29 ) 88.92 ( 76.46 ) 80.28 ( 69.03 ) 88.31 ( 75.93 )
29.0 81.20 ( 69.82 ) 89.90 ( 77.30 ) 80.87 ( 69.53 ) 89.23 ( 76.72 ) 80.56 ( 69.27 ) 88.61 ( 76.19 )
29.1 81.48 ( 70.06 ) 90.21 ( 77.57 ) 81.14 ( 69.77 ) 89.54 ( 76.99 ) 80.83 ( 69.50 ) 88.92 ( 76.45 )
29.2 81.76 ( 70.30 ) 90.52 ( 77.83 ) 81.42 ( 70.01 ) 89.85 ( 77.25 ) 81.11 ( 69.74 ) 89.22 ( 76.72 )
29.3 82.04 ( 70.54 ) 90.83 ( 78.10 ) 81.70 ( 70.25 ) 90.15 ( 77.52 ) 81.39 ( 69.98 ) 89.53 ( 76.98 )
29.4 82.32 ( 70.78 ) 91.14 ( 78.37 ) 81.98 ( 70.49 ) 90.46 ( 77.78 ) 81.67 ( 70.22 ) 89.83 ( 77.24 )
29.5 82.60 ( 71.02 ) 91.45 ( 78.63 ) 82.26 ( 70.73 ) 90.77 ( 78.05 ) 81.94 ( 70.46 ) 90.14 ( 77.51 )
29.6 82.88 ( 71.26 ) 91.76 ( 78.90 ) 82.54 ( 70.97 ) 91.08 ( 78.31 ) 82.22 ( 70.70 ) 90.44 ( 77.77 )
29.7 83.16 ( 71.50 ) 92.07 ( 79.17 ) 82.82 ( 71.21 ) 91.38 ( 78.58 ) 82.50 ( 70.94 ) 90.75 ( 78.03 )
29.8 83.44 ( 71.75 ) 92.38 ( 79.43 ) 83.10 ( 71.45 ) 91.69 ( 78.84 ) 82.78 ( 71.18 ) 91.06 ( 78.29 )
29.9 83.72 ( 71.99 ) 92.69 ( 79.70 ) 83.37 ( 71.69 ) 92.00 ( 79.11 ) 83.06 ( 71.41 ) 91.36 ( 78.56 )
30.0 84.00 ( 72.23 ) 93.00 ( 79.97 ) 83.65 ( 71.93 ) 92.31 ( 79.37 ) 83.33 ( 71.65 ) 91.67 ( 78.82 )
30.1 84.28 ( 72.47 ) 93.31 ( 80.23 ) 83.93 ( 72.17 ) 92.62 ( 79.63 ) 83.61 ( 71.89 ) 91.97 ( 79.08 )
30.2 84.56 ( 72.71 ) 93.62 ( 80.50 ) 84.21 ( 72.41 ) 92.92 ( 79.90 ) 83.89 ( 72.13 ) 92.28 ( 79.34 )
30.3 84.84 ( 72.95 ) 93.93 ( 80.77 ) 84.49 ( 72.65 ) 93.23 ( 80.16 ) 84.17 ( 72.37 ) 92.58 ( 79.61 )
30.4 85.12 ( 73.19 ) 94.24 ( 81.03 ) 84.77 ( 72.89 ) 93.54 ( 80.43 ) 84.44 ( 72.61 ) 92.89 ( 79.87 )
30.5 85.40 ( 73.43 ) 94.55 ( 81.30 ) 85.05 ( 73.13 ) 93.85 ( 80.69 ) 84.72 ( 72.85 ) 93.19 ( 80.13 )
30.6 85.68 ( 73.67 ) 94.86 ( 81.56 ) 85.33 ( 73.37 ) 94.15 ( 80.96 ) 85.00 ( 73.09 ) 93.50 ( 80.40 )
30.7 85.96 ( 73.91 ) 95.17 ( 81.83 ) 85.61 ( 73.61 ) 94.46 ( 81.22 ) 85.28 ( 73.33 ) 93.81 ( 80.66 )
30.8 86.24 ( 74.15 ) 95.48 ( 82.10 ) 85.88 ( 73.85 ) 94.77 ( 81.49 ) 85.56 ( 73.56 ) 94.11 ( 80.92 )
30.9 86.52 ( 74.39 ) 95.79 ( 82.36 ) 86.16 ( 74.09 ) 95.08 ( 81.75 ) 85.83 ( 73.80 ) 94.42 ( 81.18 )

1-102 FAN-2209 201709


SELECTION DATA

Table 35. Outdoor Unit Capacity (JTOR500~540VAE(U,F,R)BS1) with Total Horsepower of Combined Indoor Unit (2)
Total Outdoor Unit Capacity: kW (×1000kcal/h)
RAS-50FSXNS
JTOR500VAE(U,F,R)BS1 RAS-52FSXNS
JTOR520VAE(U,F,R)BS1 RAS-54FSXNS
JTOR540VAE(U,F,R)BS1
Cooling Heating Cooling Heating Cooling Heating
31.0 86.80 ( 74.63 ) 96.10 ( 82.63 ) 86.44 ( 74.33 ) 95.38 ( 82.02 ) 86.11 ( 74.04 ) 94.72 ( 81.45 )
31.1 87.08 ( 74.88 ) 96.41 ( 82.90 ) 86.72 ( 74.57 ) 95.69 ( 82.28 ) 86.39 ( 74.28 ) 95.03 ( 81.71 )
31.2 87.36 ( 75.12 ) 96.72 ( 83.16 ) 87.00 ( 74.81 ) 96.00 ( 82.55 ) 86.67 ( 74.52 ) 95.33 ( 81.97 )
31.3 87.64 ( 75.36 ) 97.03 ( 83.43 ) 87.28 ( 75.05 ) 96.31 ( 82.81 ) 86.94 ( 74.76 ) 95.64 ( 82.23 )
31.4 87.92 ( 75.60 ) 97.34 ( 83.70 ) 87.56 ( 75.29 ) 96.62 ( 83.07 ) 87.22 ( 75.00 ) 95.94 ( 82.50 )
31.5 88.20 ( 75.84 ) 97.65 ( 83.96 ) 87.84 ( 75.53 ) 96.92 ( 83.34 ) 87.50 ( 75.24 ) 96.25 ( 82.76 )
31.6 88.48 ( 76.08 ) 97.96 ( 84.23 ) 88.12 ( 75.77 ) 97.23 ( 83.60 ) 87.78 ( 75.48 ) 96.56 ( 83.02 )
31.7 88.76 ( 76.32 ) 98.27 ( 84.50 ) 88.39 ( 76.01 ) 97.54 ( 83.87 ) 88.06 ( 75.71 ) 96.86 ( 83.29 )
31.8 89.04 ( 76.56 ) 98.58 ( 84.76 ) 88.67 ( 76.25 ) 97.85 ( 84.13 ) 88.33 ( 75.95 ) 97.17 ( 83.55 )
31.9 89.32 ( 76.80 ) 98.89 ( 85.03 ) 88.95 ( 76.48 ) 98.15 ( 84.40 ) 88.61 ( 76.19 ) 97.47 ( 83.81 )
32.0 89.60 ( 77.04 ) 99.20 ( 85.30 ) 89.23 ( 76.72 ) 98.46 ( 84.66 ) 88.89 ( 76.43 ) 97.78 ( 84.07 )
32.1 89.88 ( 77.28 ) 99.51 ( 85.56 ) 89.51 ( 76.96 ) 98.77 ( 84.93 ) 89.17 ( 76.67 ) 98.08 ( 84.34 )
32.2 90.16 ( 77.52 ) 99.82 ( 85.83 ) 89.79 ( 77.20 ) 99.08 ( 85.19 ) 89.44 ( 76.91 ) 98.39 ( 84.60 )
32.3 90.44 ( 77.76 ) 100.13 ( 86.10 ) 90.07 ( 77.44 ) 99.38 ( 85.46 ) 89.72 ( 77.15 ) 98.69 ( 84.86 )
32.4 90.72 ( 78.01 ) 100.44 ( 86.36 ) 90.35 ( 77.68 ) 99.69 ( 85.72 ) 90.00 ( 77.39 ) 99.00 ( 85.12 )
32.5 91.00 ( 78.25 ) 100.75 ( 86.63 ) 90.62 ( 77.92 ) 100.00 ( 85.98 ) 90.28 ( 77.62 ) 99.31 ( 85.39 )
32.6 91.28 ( 78.49 ) 101.06 ( 86.90 ) 90.90 ( 78.16 ) 100.31 ( 86.25 ) 90.56 ( 77.86 ) 99.61 ( 85.65 )
32.7 91.56 ( 78.73 ) 101.37 ( 87.16 ) 91.18 ( 78.40 ) 100.62 ( 86.51 ) 90.83 ( 78.10 ) 99.92 ( 85.91 )
32.8 91.84 ( 78.97 ) 101.68 ( 87.43 ) 91.46 ( 78.64 ) 100.92 ( 86.78 ) 91.11 ( 78.34 ) 100.22 ( 86.18 )
32.9 92.12 ( 79.21 ) 101.99 ( 87.70 ) 91.74 ( 78.88 ) 101.23 ( 87.04 ) 91.39 ( 78.58 ) 100.53 ( 86.44 )
33.0 92.40 ( 79.45 ) 102.30 ( 87.96 ) 92.02 ( 79.12 ) 101.54 ( 87.31 ) 91.67 ( 78.82 ) 100.83 ( 86.70 )
33.1 92.68 ( 79.69 ) 102.61 ( 88.23 ) 92.30 ( 79.36 ) 101.85 ( 87.57 ) 91.94 ( 79.06 ) 101.14 ( 86.96 )
33.2 92.96 ( 79.93 ) 102.92 ( 88.50 ) 92.58 ( 79.60 ) 102.15 ( 87.84 ) 92.22 ( 79.30 ) 101.44 ( 87.23 )
33.3 93.24 ( 80.17 ) 103.23 ( 88.76 ) 92.86 ( 79.84 ) 102.46 ( 88.10 ) 92.50 ( 79.54 ) 101.75 ( 87.49 )
33.4 93.52 ( 80.41 ) 103.54 ( 89.03 ) 93.13 ( 80.08 ) 102.77 ( 88.37 ) 92.78 ( 79.77 ) 102.06 ( 87.75 )
33.5 93.80 ( 80.65 ) 103.85 ( 89.29 ) 93.41 ( 80.32 ) 103.08 ( 88.63 ) 93.06 ( 80.01 ) 102.36 ( 88.01 )
33.6 94.08 ( 80.89 ) 104.16 ( 89.56 ) 93.69 ( 80.56 ) 103.38 ( 88.89 ) 93.33 ( 80.25 ) 102.67 ( 88.28 )
33.7 94.36 ( 81.13 ) 104.47 ( 89.83 ) 93.97 ( 80.80 ) 103.69 ( 89.16 ) 93.61 ( 80.49 ) 102.97 ( 88.54 )
33.8 94.64 ( 81.38 ) 104.78 ( 90.09 ) 94.25 ( 81.04 ) 104.00 ( 89.42 ) 93.89 ( 80.73 ) 103.28 ( 88.80 )
33.9 94.92 ( 81.62 ) 105.09 ( 90.36 ) 94.53 ( 81.28 ) 104.31 ( 89.69 ) 94.17 ( 80.97 ) 103.58 ( 89.07 )
34.0 95.20 ( 81.86 ) 105.40 ( 90.63 ) 94.81 ( 81.52 ) 104.62 ( 89.95 ) 94.44 ( 81.21 ) 103.89 ( 89.33 )
34.1 95.48 ( 82.10 ) 105.71 ( 90.89 ) 95.09 ( 81.76 ) 104.92 ( 90.22 ) 94.72 ( 81.45 ) 104.19 ( 89.59 )
34.2 95.76 ( 82.34 ) 106.02 ( 91.16 ) 95.37 ( 82.00 ) 105.23 ( 90.48 ) 95.00 ( 81.69 ) 104.50 ( 89.85 )
34.3 96.04 ( 82.58 ) 106.33 ( 91.43 ) 95.64 ( 82.24 ) 105.54 ( 90.75 ) 95.28 ( 81.92 ) 104.81 ( 90.12 )
34.4 96.32 ( 82.82 ) 106.64 ( 91.69 ) 95.92 ( 82.48 ) 105.85 ( 91.01 ) 95.56 ( 82.16 ) 105.11 ( 90.38 )
34.5 96.60 ( 83.06 ) 106.95 ( 91.96 ) 96.20 ( 82.72 ) 106.15 ( 91.28 ) 95.83 ( 82.40 ) 105.42 ( 90.64 )
34.6 96.88 ( 83.30 ) 107.26 ( 92.23 ) 96.48 ( 82.96 ) 106.46 ( 91.54 ) 96.11 ( 82.64 ) 105.72 ( 90.90 )
34.7 97.16 ( 83.54 ) 107.57 ( 92.49 ) 96.76 ( 83.20 ) 106.77 ( 91.81 ) 96.39 ( 82.88 ) 106.03 ( 91.17 )
34.8 97.44 ( 83.78 ) 107.88 ( 92.76 ) 97.04 ( 83.44 ) 107.08 ( 92.07 ) 96.67 ( 83.12 ) 106.33 ( 91.43 )
34.9 97.72 ( 84.02 ) 108.19 ( 93.03 ) 97.32 ( 83.68 ) 107.38 ( 92.33 ) 96.94 ( 83.36 ) 106.64 ( 91.69 )
35.0 98.00 ( 84.26 ) 108.50 ( 93.29 ) 97.60 ( 83.92 ) 107.69 ( 92.60 ) 97.22 ( 83.60 ) 106.94 ( 91.96 )
35.1 98.28 ( 84.51 ) 108.81 ( 93.56 ) 97.88 ( 84.16 ) 108.00 ( 92.86 ) 97.50 ( 83.83 ) 107.25 ( 92.22 )
35.2 98.56 ( 84.75 ) 109.12 ( 93.83 ) 98.15 ( 84.40 ) 108.31 ( 93.13 ) 97.78 ( 84.07 ) 107.56 ( 92.48 )
35.3 98.84 ( 84.99 ) 109.43 ( 94.09 ) 98.43 ( 84.64 ) 108.62 ( 93.39 ) 98.06 ( 84.31 ) 107.86 ( 92.74 )
35.4 99.12 ( 85.23 ) 109.74 ( 94.36 ) 98.71 ( 84.88 ) 108.92 ( 93.66 ) 98.33 ( 84.55 ) 108.17 ( 93.01 )
35.5 99.40 ( 85.47 ) 110.05 ( 94.63 ) 98.99 ( 85.12 ) 109.23 ( 93.92 ) 98.61 ( 84.79 ) 108.47 ( 93.27 )
35.6 99.68 ( 85.71 ) 110.36 ( 94.89 ) 99.27 ( 85.36 ) 109.54 ( 94.19 ) 98.89 ( 85.03 ) 108.78 ( 93.53 )
35.7 99.96 ( 85.95 ) 110.67 ( 95.16 ) 99.55 ( 85.60 ) 109.85 ( 94.45 ) 99.17 ( 85.27 ) 109.08 ( 93.79 )
35.8 100.24 ( 86.19 ) 110.98 ( 95.43 ) 99.83 ( 85.84 ) 110.15 ( 94.72 ) 99.44 ( 85.51 ) 109.39 ( 94.06 )
35.9 100.52 ( 86.43 ) 111.29 ( 95.69 ) 100.11 ( 86.08 ) 110.46 ( 94.98 ) 99.72 ( 85.75 ) 109.69 ( 94.32 )
36.0 100.80 ( 86.67 ) 111.60 ( 95.96 ) 100.38 ( 86.32 ) 110.77 ( 95.24 ) 100.00 ( 85.98 ) 110.00 ( 94.58 )
36.1 101.08 ( 86.91 ) 111.91 ( 96.23 ) 100.66 ( 86.55 ) 111.08 ( 95.51 ) 100.28 ( 86.22 ) 110.31 ( 94.85 )
36.2 101.36 ( 87.15 ) 112.22 ( 96.49 ) 100.94 ( 86.79 ) 111.38 ( 95.77 ) 100.56 ( 86.46 ) 110.61 ( 95.11 )
36.3 101.64 ( 87.39 ) 112.53 ( 96.76 ) 101.22 ( 87.03 ) 111.69 ( 96.04 ) 100.83 ( 86.70 ) 110.92 ( 95.37 )
36.4 101.92 ( 87.64 ) 112.84 ( 97.02 ) 101.50 ( 87.27 ) 112.00 ( 96.30 ) 101.11 ( 86.94 ) 111.22 ( 95.63 )
36.5 102.20 ( 87.88 ) 113.15 ( 97.29 ) 101.78 ( 87.51 ) 112.31 ( 96.57 ) 101.39 ( 87.18 ) 111.53 ( 95.90 )
36.6 102.48 ( 88.12 ) 113.46 ( 97.56 ) 102.06 ( 87.75 ) 112.62 ( 96.83 ) 101.67 ( 87.42 ) 111.83 ( 96.16 )
36.7 102.76 ( 88.36 ) 113.77 ( 97.82 ) 102.34 ( 87.99 ) 112.92 ( 97.10 ) 101.94 ( 87.66 ) 112.14 ( 96.42 )
36.8 103.04 ( 88.60 ) 114.08 ( 98.09 ) 102.62 ( 88.23 ) 113.23 ( 97.36 ) 102.22 ( 87.90 ) 112.44 ( 96.68 )
36.9 103.32 ( 88.84 ) 114.39 ( 98.36 ) 102.89 ( 88.47 ) 113.54 ( 97.63 ) 102.50 ( 88.13 ) 112.75 ( 96.95 )

FAN-2209 201709 1-103


SELECTION DATA

Table 36. Outdoor Unit Capacity (JTOR500~540VAE(U,F,R)BS1) with Total Horsepower of Combined Indoor Unit (3)
Total Outdoor Unit Capacity: kW (×1000kcal/h)
RAS-50FSXNS
JTOR500VAE(U,F,R)BS1 RAS-52FSXNS
JTOR520VAE(U,F,R)BS1 RAS-54FSXNS
JTOR540VAE(U,F,R)BS1
Cooling Heating Cooling Heating Cooling Heating
37.0 103.60 ( 89.08 ) 114.70 ( 98.62 ) 103.17 ( 88.71 ) 113.85 ( 97.89 ) 102.78 ( 88.37 ) 113.06 ( 97.21 )
37.1 103.88 ( 89.32 ) 115.01 ( 98.89 ) 103.45 ( 88.95 ) 114.15 ( 98.15 ) 103.06 ( 88.61 ) 113.36 ( 97.47 )
37.2 104.16 ( 89.56 ) 115.32 ( 99.16 ) 103.73 ( 89.19 ) 114.46 ( 98.42 ) 103.33 ( 88.85 ) 113.67 ( 97.74 )
37.3 104.44 ( 89.80 ) 115.63 ( 99.42 ) 104.01 ( 89.43 ) 114.77 ( 98.68 ) 103.61 ( 89.09 ) 113.97 ( 98.00 )
37.4 104.72 ( 90.04 ) 115.94 ( 99.69 ) 104.29 ( 89.67 ) 115.08 ( 98.95 ) 103.89 ( 89.33 ) 114.28 ( 98.26 )
37.5 105.00 ( 90.28 ) 116.25 ( 99.96 ) 104.57 ( 89.91 ) 115.38 ( 99.21 ) 104.17 ( 89.57 ) 114.58 ( 98.52 )
37.6 105.28 ( 90.52 ) 116.56 ( 100.22 ) 104.85 ( 90.15 ) 115.69 ( 99.48 ) 104.44 ( 89.81 ) 114.89 ( 98.79 )
37.7 105.56 ( 90.77 ) 116.87 ( 100.49 ) 105.13 ( 90.39 ) 116.00 ( 99.74 ) 104.72 ( 90.04 ) 115.19 ( 99.05 )
37.8 105.84 ( 91.01 ) 117.18 ( 100.76 ) 105.40 ( 90.63 ) 116.31 ( 100.01 ) 105.00 ( 90.28 ) 115.50 ( 99.31 )
37.9 106.12 ( 91.25 ) 117.49 ( 101.02 ) 105.68 ( 90.87 ) 116.62 ( 100.27 ) 105.28 ( 90.52 ) 115.81 ( 99.57 )
38.0 106.40 ( 91.49 ) 117.80 ( 101.29 ) 105.96 ( 91.11 ) 116.92 ( 100.54 ) 105.56 ( 90.76 ) 116.11 ( 99.84 )
38.1 106.68 ( 91.73 ) 118.11 ( 101.56 ) 106.24 ( 91.35 ) 117.23 ( 100.80 ) 105.83 ( 91.00 ) 116.42 ( 100.10 )
38.2 106.96 ( 91.97 ) 118.42 ( 101.82 ) 106.52 ( 91.59 ) 117.54 ( 101.06 ) 106.11 ( 91.24 ) 116.72 ( 100.36 )
38.3 107.24 ( 92.21 ) 118.73 ( 102.09 ) 106.80 ( 91.83 ) 117.85 ( 101.33 ) 106.39 ( 91.48 ) 117.03 ( 100.63 )
38.4 107.52 ( 92.45 ) 119.04 ( 102.36 ) 107.08 ( 92.07 ) 118.15 ( 101.59 ) 106.67 ( 91.72 ) 117.33 ( 100.89 )
38.5 107.80 ( 92.69 ) 119.35 ( 102.62 ) 107.36 ( 92.31 ) 118.46 ( 101.86 ) 106.94 ( 91.96 ) 117.64 ( 101.15 )
38.6 108.08 ( 92.93 ) 119.66 ( 102.89 ) 107.63 ( 92.55 ) 118.77 ( 102.12 ) 107.22 ( 92.19 ) 117.94 ( 101.41 )
38.7 108.36 ( 93.17 ) 119.97 ( 103.16 ) 107.91 ( 92.79 ) 119.08 ( 102.39 ) 107.50 ( 92.43 ) 118.25 ( 101.68 )
38.8 108.64 ( 93.41 ) 120.28 ( 103.42 ) 108.19 ( 93.03 ) 119.38 ( 102.65 ) 107.78 ( 92.67 ) 118.56 ( 101.94 )
38.9 108.92 ( 93.65 ) 120.59 ( 103.69 ) 108.47 ( 93.27 ) 119.69 ( 102.92 ) 108.06 ( 92.91 ) 118.86 ( 102.20 )
39.0 109.20 ( 93.90 ) 120.90 ( 103.96 ) 108.75 ( 93.51 ) 120.00 ( 103.18 ) 108.33 ( 93.15 ) 119.17 ( 102.46 )
39.1 109.48 ( 94.14 ) 121.21 ( 104.22 ) 109.03 ( 93.75 ) 120.31 ( 103.45 ) 108.61 ( 93.39 ) 119.47 ( 102.73 )
39.2 109.76 ( 94.38 ) 121.52 ( 104.49 ) 109.31 ( 93.99 ) 120.62 ( 103.71 ) 108.89 ( 93.63 ) 119.78 ( 102.99 )
39.3 110.04 ( 94.62 ) 121.83 ( 104.75 ) 109.59 ( 94.23 ) 120.92 ( 103.98 ) 109.17 ( 93.87 ) 120.08 ( 103.25 )
39.4 110.32 ( 94.86 ) 122.14 ( 105.02 ) 109.87 ( 94.47 ) 121.23 ( 104.24 ) 109.44 ( 94.11 ) 120.39 ( 103.52 )
39.5 110.60 ( 95.10 ) 122.45 ( 105.29 ) 110.14 ( 94.71 ) 121.54 ( 104.50 ) 109.72 ( 94.34 ) 120.69 ( 103.78 )
39.6 110.88 ( 95.34 ) 122.76 ( 105.55 ) 110.42 ( 94.95 ) 121.85 ( 104.77 ) 110.00 ( 94.58 ) 121.00 ( 104.04 )
39.7 111.16 ( 95.58 ) 123.07 ( 105.82 ) 110.70 ( 95.19 ) 122.15 ( 105.03 ) 110.28 ( 94.82 ) 121.31 ( 104.30 )
39.8 111.44 ( 95.82 ) 123.38 ( 106.09 ) 110.98 ( 95.43 ) 122.46 ( 105.30 ) 110.56 ( 95.06 ) 121.61 ( 104.57 )
39.9 111.72 ( 96.06 ) 123.69 ( 106.35 ) 111.26 ( 95.67 ) 122.77 ( 105.56 ) 110.83 ( 95.30 ) 121.92 ( 104.83 )
40.0 112.00 ( 96.30 ) 124.00 ( 106.62 ) 111.54 ( 95.91 ) 123.08 ( 105.83 ) 111.11 ( 95.54 ) 122.22 ( 105.09 )
40.1 112.28 ( 96.54 ) 124.31 ( 106.89 ) 111.82 ( 96.15 ) 123.38 ( 106.09 ) 111.39 ( 95.78 ) 122.53 ( 105.35 )
40.2 112.56 ( 96.78 ) 124.62 ( 107.15 ) 112.10 ( 96.39 ) 123.69 ( 106.36 ) 111.67 ( 96.02 ) 122.83 ( 105.62 )
40.3 112.84 ( 97.02 ) 124.93 ( 107.42 ) 112.38 ( 96.63 ) 124.00 ( 106.62 ) 111.94 ( 96.25 ) 123.14 ( 105.88 )
40.4 113.12 ( 97.27 ) 125.24 ( 107.69 ) 112.65 ( 96.86 ) 124.31 ( 106.89 ) 112.22 ( 96.49 ) 123.44 ( 106.14 )
40.5 113.40 ( 97.51 ) 125.55 ( 107.95 ) 112.93 ( 97.10 ) 124.62 ( 107.15 ) 112.50 ( 96.73 ) 123.75 ( 106.41 )
40.6 113.68 ( 97.75 ) 125.86 ( 108.22 ) 113.21 ( 97.34 ) 124.92 ( 107.41 ) 112.78 ( 96.97 ) 124.06 ( 106.67 )
40.7 113.96 ( 97.99 ) 126.17 ( 108.49 ) 113.49 ( 97.58 ) 125.23 ( 107.68 ) 113.06 ( 97.21 ) 124.36 ( 106.93 )
40.8 114.24 ( 98.23 ) 126.48 ( 108.75 ) 113.77 ( 97.82 ) 125.54 ( 107.94 ) 113.33 ( 97.45 ) 124.67 ( 107.19 )
40.9 114.52 ( 98.47 ) 126.79 ( 109.02 ) 114.05 ( 98.06 ) 125.85 ( 108.21 ) 113.61 ( 97.69 ) 124.97 ( 107.46 )
41.0 114.80 ( 98.71 ) 127.10 ( 109.29 ) 114.33 ( 98.30 ) 126.15 ( 108.47 ) 113.89 ( 97.93 ) 125.28 ( 107.72 )
41.1 115.08 ( 98.95 ) 127.41 ( 109.55 ) 114.61 ( 98.54 ) 126.46 ( 108.74 ) 114.17 ( 98.17 ) 125.58 ( 107.98 )
41.2 115.36 ( 99.19 ) 127.72 ( 109.82 ) 114.88 ( 98.78 ) 126.77 ( 109.00 ) 114.44 ( 98.40 ) 125.89 ( 108.24 )
41.3 115.64 ( 99.43 ) 128.03 ( 110.09 ) 115.16 ( 99.02 ) 127.08 ( 109.27 ) 114.72 ( 98.64 ) 126.19 ( 108.51 )
41.4 115.92 ( 99.67 ) 128.34 ( 110.35 ) 115.44 ( 99.26 ) 127.38 ( 109.53 ) 115.00 ( 98.88 ) 126.50 ( 108.77 )
41.5 116.20 ( 99.91 ) 128.65 ( 110.62 ) 115.72 ( 99.50 ) 127.69 ( 109.80 ) 115.28 ( 99.12 ) 126.81 ( 109.03 )
41.6 116.48 ( 100.15 ) 128.96 ( 110.89 ) 116.00 ( 99.74 ) 128.00 ( 110.06 ) 115.56 ( 99.36 ) 127.11 ( 109.30 )
41.7 116.76 ( 100.40 ) 129.27 ( 111.15 ) 116.28 ( 99.98 ) 128.31 ( 110.32 ) 115.83 ( 99.60 ) 127.42 ( 109.56 )
41.8 117.04 ( 100.64 ) 129.58 ( 111.42 ) 116.56 ( 100.22 ) 128.62 ( 110.59 ) 116.11 ( 99.84 ) 127.72 ( 109.82 )
41.9 117.32 ( 100.88 ) 129.89 ( 111.69 ) 116.84 ( 100.46 ) 128.92 ( 110.85 ) 116.39 ( 100.08 ) 128.03 ( 110.08 )
42.0 117.60 ( 101.12 ) 130.20 ( 111.95 ) 117.12 ( 100.70 ) 129.23 ( 111.12 ) 116.67 ( 100.32 ) 128.33 ( 110.35 )
42.1 117.88 ( 101.36 ) 130.51 ( 112.22 ) 117.39 ( 100.94 ) 129.54 ( 111.38 ) 116.94 ( 100.55 ) 128.64 ( 110.61 )
42.2 118.16 ( 101.60 ) 130.82 ( 112.48 ) 117.67 ( 101.18 ) 129.85 ( 111.65 ) 117.22 ( 100.79 ) 128.94 ( 110.87 )
42.3 118.44 ( 101.84 ) 131.13 ( 112.75 ) 117.95 ( 101.42 ) 130.15 ( 111.91 ) 117.50 ( 101.03 ) 129.25 ( 111.13 )
42.4 118.72 ( 102.08 ) 131.44 ( 113.02 ) 118.23 ( 101.66 ) 130.46 ( 112.18 ) 117.78 ( 101.27 ) 129.56 ( 111.40 )
42.5 119.00 ( 102.32 ) 131.75 ( 113.28 ) 118.51 ( 101.90 ) 130.77 ( 112.44 ) 118.06 ( 101.51 ) 129.86 ( 111.66 )
42.6 119.28 ( 102.56 ) 132.06 ( 113.55 ) 118.79 ( 102.14 ) 131.08 ( 112.71 ) 118.33 ( 101.75 ) 130.17 ( 111.92 )
42.7 119.56 ( 102.80 ) 132.37 ( 113.82 ) 119.07 ( 102.38 ) 131.38 ( 112.97 ) 118.61 ( 101.99 ) 130.47 ( 112.19 )
42.8 119.84 ( 103.04 ) 132.68 ( 114.08 ) 119.35 ( 102.62 ) 131.69 ( 113.24 ) 118.89 ( 102.23 ) 130.78 ( 112.45 )
42.9 120.12 ( 103.28 ) 132.99 ( 114.35 ) 119.63 ( 102.86 ) 132.00 ( 113.50 ) 119.17 ( 102.46 ) 131.08 ( 112.71 )

1-104 FAN-2209 201709


SELECTION DATA

Table 37. Outdoor Unit Capacity (JTOR500~540VAE(U,F,R)BS1) with Total Horsepower of Combined Indoor Unit (4)
Total Outdoor Unit Capacity: kW (×1000kcal/h)
RAS-50FSXNS
JTOR500VAE(U,F,R)BS1 RAS-52FSXNS
JTOR520VAE(U,F,R)BS1 RAS-54FSXNS
JTOR540VAE(U,F,R)BS1
Cooling Heating Cooling Heating Cooling Heating
43.0 120.40 ( 103.53 ) 133.30 ( 114.62 ) 119.90 ( 103.10 ) 132.31 ( 113.76 ) 119.44 ( 102.70 ) 131.39 ( 112.97 )
43.1 120.68 ( 103.77 ) 133.61 ( 114.88 ) 120.18 ( 103.34 ) 132.62 ( 114.03 ) 119.72 ( 102.94 ) 131.69 ( 113.24 )
43.2 120.96 ( 104.01 ) 133.92 ( 115.15 ) 120.46 ( 103.58 ) 132.92 ( 114.29 ) 120.00 ( 103.18 ) 132.00 ( 113.50 )
43.3 121.24 ( 104.25 ) 134.23 ( 115.42 ) 120.74 ( 103.82 ) 133.23 ( 114.56 ) 120.28 ( 103.42 ) 132.31 ( 113.76 )
43.4 121.52 ( 104.49 ) 134.54 ( 115.68 ) 121.02 ( 104.06 ) 133.54 ( 114.82 ) 120.56 ( 103.66 ) 132.61 ( 114.03 )
43.5 121.80 ( 104.73 ) 134.85 ( 115.95 ) 121.30 ( 104.30 ) 133.85 ( 115.09 ) 120.83 ( 103.90 ) 132.92 ( 114.29 )
43.6 122.08 ( 104.97 ) 135.16 ( 116.22 ) 121.58 ( 104.54 ) 134.15 ( 115.35 ) 121.11 ( 104.14 ) 133.22 ( 114.55 )
43.7 122.36 ( 105.21 ) 135.47 ( 116.48 ) 121.86 ( 104.78 ) 134.46 ( 115.62 ) 121.39 ( 104.38 ) 133.53 ( 114.81 )
43.8 122.64 ( 105.45 ) 135.78 ( 116.75 ) 122.13 ( 105.02 ) 134.77 ( 115.88 ) 121.67 ( 104.61 ) 133.83 ( 115.08 )
43.9 122.92 ( 105.69 ) 136.09 ( 117.02 ) 122.41 ( 105.26 ) 135.08 ( 116.15 ) 121.94 ( 104.85 ) 134.14 ( 115.34 )
44.0 123.20 ( 105.93 ) 136.40 ( 117.28 ) 122.69 ( 105.50 ) 135.38 ( 116.41 ) 122.22 ( 105.09 ) 134.44 ( 115.60 )
44.1 123.48 ( 106.17 ) 136.71 ( 117.55 ) 122.97 ( 105.74 ) 135.69 ( 116.67 ) 122.50 ( 105.33 ) 134.75 ( 115.86 )
44.2 123.76 ( 106.41 ) 137.02 ( 117.82 ) 123.25 ( 105.98 ) 136.00 ( 116.94 ) 122.78 ( 105.57 ) 135.06 ( 116.13 )
44.3 124.04 ( 106.66 ) 137.33 ( 118.08 ) 123.53 ( 106.22 ) 136.31 ( 117.20 ) 123.06 ( 105.81 ) 135.36 ( 116.39 )
44.4 124.32 ( 106.90 ) 137.64 ( 118.35 ) 123.81 ( 106.46 ) 136.62 ( 117.47 ) 123.33 ( 106.05 ) 135.67 ( 116.65 )
44.5 124.60 ( 107.14 ) 137.95 ( 118.62 ) 124.09 ( 106.70 ) 136.92 ( 117.73 ) 123.61 ( 106.29 ) 135.97 ( 116.92 )
44.6 124.88 ( 107.38 ) 138.26 ( 118.88 ) 124.37 ( 106.93 ) 137.23 ( 118.00 ) 123.89 ( 106.53 ) 136.28 ( 117.18 )
44.7 125.16 ( 107.62 ) 138.57 ( 119.15 ) 124.64 ( 107.17 ) 137.54 ( 118.26 ) 124.17 ( 106.76 ) 136.58 ( 117.44 )
44.8 125.44 ( 107.86 ) 138.88 ( 119.42 ) 124.92 ( 107.41 ) 137.85 ( 118.53 ) 124.44 ( 107.00 ) 136.89 ( 117.70 )
44.9 125.72 ( 108.10 ) 139.19 ( 119.68 ) 125.20 ( 107.65 ) 138.15 ( 118.79 ) 124.72 ( 107.24 ) 137.19 ( 117.97 )
45.0 126.00 ( 108.34 ) 139.50 ( 119.95 ) 125.48 ( 107.89 ) 138.46 ( 119.06 ) 125.00 ( 107.48 ) 137.50 ( 118.23 )
45.1 126.28 ( 108.58 ) 139.81 ( 120.21 ) 125.76 ( 108.13 ) 138.77 ( 119.32 ) 125.28 ( 107.72 ) 137.81 ( 118.49 )
45.2 126.56 ( 108.82 ) 140.12 ( 120.48 ) 126.04 ( 108.37 ) 139.08 ( 119.58 ) 125.56 ( 107.96 ) 138.11 ( 118.75 )
45.3 126.84 ( 109.06 ) 140.43 ( 120.75 ) 126.32 ( 108.61 ) 139.38 ( 119.85 ) 125.83 ( 108.20 ) 138.42 ( 119.02 )
45.4 127.12 ( 109.30 ) 140.74 ( 121.01 ) 126.60 ( 108.85 ) 139.69 ( 120.11 ) 126.11 ( 108.44 ) 138.72 ( 119.28 )
45.5 127.40 ( 109.54 ) 141.05 ( 121.28 ) 126.88 ( 109.09 ) 140.00 ( 120.38 ) 126.39 ( 108.67 ) 139.03 ( 119.54 )
45.6 127.68 ( 109.79 ) 141.36 ( 121.55 ) 127.15 ( 109.33 ) 140.31 ( 120.64 ) 126.67 ( 108.91 ) 139.33 ( 119.81 )
45.7 127.96 ( 110.03 ) 141.67 ( 121.81 ) 127.43 ( 109.57 ) 140.62 ( 120.91 ) 126.94 ( 109.15 ) 139.64 ( 120.07 )
45.8 128.24 ( 110.27 ) 141.98 ( 122.08 ) 127.71 ( 109.81 ) 140.92 ( 121.17 ) 127.22 ( 109.39 ) 139.94 ( 120.33 )
45.9 128.52 ( 110.51 ) 142.29 ( 122.35 ) 127.99 ( 110.05 ) 141.23 ( 121.44 ) 127.50 ( 109.63 ) 140.25 ( 120.59 )
46.0 128.80 ( 110.75 ) 142.60 ( 122.61 ) 128.27 ( 110.29 ) 141.54 ( 121.70 ) 127.78 ( 109.87 ) 140.56 ( 120.86 )
46.1 129.08 ( 110.99 ) 142.91 ( 122.88 ) 128.55 ( 110.53 ) 141.85 ( 121.97 ) 128.06 ( 110.11 ) 140.86 ( 121.12 )
46.2 129.36 ( 111.23 ) 143.22 ( 123.15 ) 128.83 ( 110.77 ) 142.15 ( 122.23 ) 128.33 ( 110.35 ) 141.17 ( 121.38 )
46.3 129.64 ( 111.47 ) 143.53 ( 123.41 ) 129.11 ( 111.01 ) 142.46 ( 122.49 ) 128.61 ( 110.59 ) 141.47 ( 121.64 )
46.4 129.92 ( 111.71 ) 143.84 ( 123.68 ) 129.38 ( 111.25 ) 142.77 ( 122.76 ) 128.89 ( 110.82 ) 141.78 ( 121.91 )
46.5 130.20 ( 111.95 ) 144.15 ( 123.95 ) 129.66 ( 111.49 ) 143.08 ( 123.02 ) 129.17 ( 111.06 ) 142.08 ( 122.17 )
46.6 130.48 ( 112.19 ) 144.46 ( 124.21 ) 129.94 ( 111.73 ) 143.38 ( 123.29 ) 129.44 ( 111.30 ) 142.39 ( 122.43 )
46.7 130.76 ( 112.43 ) 144.77 ( 124.48 ) 130.22 ( 111.97 ) 143.69 ( 123.55 ) 129.72 ( 111.54 ) 142.69 ( 122.70 )
46.8 131.04 ( 112.67 ) 145.08 ( 124.75 ) 130.50 ( 112.21 ) 144.00 ( 123.82 ) 130.00 ( 111.78 ) 143.00 ( 122.96 )
46.9 131.32 ( 112.91 ) 145.39 ( 125.01 ) 130.78 ( 112.45 ) 144.31 ( 124.08 ) 130.28 ( 112.02 ) 143.31 ( 123.22 )
47.0 131.60 ( 113.16 ) 145.70 ( 125.28 ) 131.06 ( 112.69 ) 144.62 ( 124.35 ) 130.56 ( 112.26 ) 143.61 ( 123.48 )
47.1 131.88 ( 113.40 ) 146.01 ( 125.55 ) 131.34 ( 112.93 ) 144.92 ( 124.61 ) 130.83 ( 112.50 ) 143.92 ( 123.75 )
47.2 132.16 ( 113.64 ) 146.32 ( 125.81 ) 131.62 ( 113.17 ) 145.23 ( 124.88 ) 131.11 ( 112.74 ) 144.22 ( 124.01 )
47.3 132.44 ( 113.88 ) 146.63 ( 126.08 ) 131.89 ( 113.41 ) 145.54 ( 125.14 ) 131.39 ( 112.97 ) 144.53 ( 124.27 )
47.4 132.72 ( 114.12 ) 146.94 ( 126.35 ) 132.17 ( 113.65 ) 145.85 ( 125.41 ) 131.67 ( 113.21 ) 144.83 ( 124.53 )
47.5 133.00 ( 114.36 ) 147.25 ( 126.61 ) 132.45 ( 113.89 ) 146.15 ( 125.67 ) 131.94 ( 113.45 ) 145.14 ( 124.80 )
47.6 133.28 ( 114.60 ) 147.56 ( 126.88 ) 132.73 ( 114.13 ) 146.46 ( 125.93 ) 132.22 ( 113.69 ) 145.44 ( 125.06 )
47.7 133.56 ( 114.84 ) 147.87 ( 127.15 ) 133.01 ( 114.37 ) 146.77 ( 126.20 ) 132.50 ( 113.93 ) 145.75 ( 125.32 )
47.8 133.84 ( 115.08 ) 148.18 ( 127.41 ) 133.29 ( 114.61 ) 147.08 ( 126.46 ) 132.78 ( 114.17 ) 146.06 ( 125.59 )
47.9 134.12 ( 115.32 ) 148.49 ( 127.68 ) 133.57 ( 114.85 ) 147.38 ( 126.73 ) 133.06 ( 114.41 ) 146.36 ( 125.85 )
48.0 134.40 ( 115.56 ) 148.80 ( 127.94 ) 133.85 ( 115.09 ) 147.69 ( 126.99 ) 133.33 ( 114.65 ) 146.67 ( 126.11 )
48.1 134.68 ( 115.80 ) 149.11 ( 128.21 ) 134.13 ( 115.33 ) 148.00 ( 127.26 ) 133.61 ( 114.88 ) 146.97 ( 126.37 )
48.2 134.96 ( 116.04 ) 149.42 ( 128.48 ) 134.40 ( 115.57 ) 148.31 ( 127.52 ) 133.89 ( 115.12 ) 147.28 ( 126.64 )
48.3 135.24 ( 116.29 ) 149.73 ( 128.74 ) 134.68 ( 115.81 ) 148.62 ( 127.79 ) 134.17 ( 115.36 ) 147.58 ( 126.90 )
48.4 135.52 ( 116.53 ) 150.04 ( 129.01 ) 134.96 ( 116.05 ) 148.92 ( 128.05 ) 134.44 ( 115.60 ) 147.89 ( 127.16 )
48.5 135.80 ( 116.77 ) 150.35 ( 129.28 ) 135.24 ( 116.29 ) 149.23 ( 128.32 ) 134.72 ( 115.84 ) 148.19 ( 127.42 )
48.6 136.08 ( 117.01 ) 150.66 ( 129.54 ) 135.52 ( 116.53 ) 149.54 ( 128.58 ) 135.00 ( 116.08 ) 148.50 ( 127.69 )
48.7 136.36 ( 117.25 ) 150.97 ( 129.81 ) 135.80 ( 116.77 ) 149.85 ( 128.84 ) 135.28 ( 116.32 ) 148.81 ( 127.95 )
48.8 136.64 ( 117.49 ) 151.28 ( 130.08 ) 136.08 ( 117.01 ) 150.15 ( 129.11 ) 135.56 ( 116.56 ) 149.11 ( 128.21 )
48.9 136.92 ( 117.73 ) 151.59 ( 130.34 ) 136.36 ( 117.24 ) 150.46 ( 129.37 ) 135.83 ( 116.80 ) 149.42 ( 128.48 )

FAN-2209 201709 1-105


SELECTION DATA

Table 38. Outdoor Unit Capacity (JTOR500~540VAE(U,F,R)BS1) with Total Horsepower of Combined Indoor Unit (5)
Total Outdoor Unit Capacity: kW (×1000kcal/h)
RAS-50FSXNS
JTOR500VAE(U,F,R)BS1 RAS-52FSXNS
JTOR520VAE(U,F,R)BS1 RAS-54FSXNS
JTOR540VAE(U,F,R)BS1
Cooling Heating Cooling Heating Cooling Heating
49.0 137.20 ( 117.97 ) 151.90 ( 130.61 ) 136.63 ( 117.48 ) 150.77 ( 129.64 ) 136.11 ( 117.03 ) 149.72 ( 128.74 )
49.1 137.48 ( 118.21 ) 152.21 ( 130.88 ) 136.91 ( 117.72 ) 151.08 ( 129.90 ) 136.39 ( 117.27 ) 150.03 ( 129.00 )
49.2 137.76 ( 118.45 ) 152.52 ( 131.14 ) 137.19 ( 117.96 ) 151.38 ( 130.17 ) 136.67 ( 117.51 ) 150.33 ( 129.26 )
49.3 138.04 ( 118.69 ) 152.83 ( 131.41 ) 137.47 ( 118.20 ) 151.69 ( 130.43 ) 136.94 ( 117.75 ) 150.64 ( 129.53 )
49.4 138.32 ( 118.93 ) 153.14 ( 131.68 ) 137.75 ( 118.44 ) 152.00 ( 130.70 ) 137.22 ( 117.99 ) 150.94 ( 129.79 )
49.5 138.60 ( 119.17 ) 153.45 ( 131.94 ) 138.03 ( 118.68 ) 152.31 ( 130.96 ) 137.50 ( 118.23 ) 151.25 ( 130.05 )
49.6 138.88 ( 119.42 ) 153.76 ( 132.21 ) 138.31 ( 118.92 ) 152.62 ( 131.23 ) 137.78 ( 118.47 ) 151.56 ( 130.31 )
49.7 139.16 ( 119.66 ) 154.07 ( 132.48 ) 138.59 ( 119.16 ) 152.92 ( 131.49 ) 138.06 ( 118.71 ) 151.86 ( 130.58 )
49.8 139.44 ( 119.90 ) 154.38 ( 132.74 ) 138.87 ( 119.40 ) 153.23 ( 131.75 ) 138.33 ( 118.95 ) 152.17 ( 130.84 )
49.9 139.72 ( 120.14 ) 154.69 ( 133.01 ) 139.14 ( 119.64 ) 153.54 ( 132.02 ) 138.61 ( 119.18 ) 152.47 ( 131.10 )
50.0 140.00 ( 120.38 ) 155.00 ( 133.28 ) 139.42 ( 119.88 ) 153.85 ( 132.28 ) 138.89 ( 119.42 ) 152.78 ( 131.37 )
50.1 140.28 ( 120.62 ) 155.31 ( 133.54 ) 139.70 ( 120.12 ) 154.15 ( 132.55 ) 139.17 ( 119.66 ) 153.08 ( 131.63 )
50.2 140.56 ( 120.86 ) 155.62 ( 133.81 ) 139.98 ( 120.36 ) 154.46 ( 132.81 ) 139.44 ( 119.90 ) 153.39 ( 131.89 )
50.3 140.84 ( 121.10 ) 155.93 ( 134.08 ) 140.26 ( 120.60 ) 154.77 ( 133.08 ) 139.72 ( 120.14 ) 153.69 ( 132.15 )
50.4 141.12 ( 121.34 ) 156.24 ( 134.34 ) 140.54 ( 120.84 ) 155.08 ( 133.34 ) 140.00 ( 120.38 ) 154.00 ( 132.42 )
50.5 141.40 ( 121.58 ) 156.55 ( 134.61 ) 140.82 ( 121.08 ) 155.38 ( 133.61 ) 140.28 ( 120.62 ) 154.31 ( 132.68 )
50.6 141.68 ( 121.82 ) 156.86 ( 134.88 ) 141.10 ( 121.32 ) 155.69 ( 133.87 ) 140.56 ( 120.86 ) 154.61 ( 132.94 )
50.7 141.96 ( 122.06 ) 157.17 ( 135.14 ) 141.38 ( 121.56 ) 156.00 ( 134.14 ) 140.83 ( 121.09 ) 154.92 ( 133.20 )
50.8 142.24 ( 122.30 ) 157.48 ( 135.41 ) 141.65 ( 121.80 ) 156.31 ( 134.40 ) 141.11 ( 121.33 ) 155.22 ( 133.47 )
50.9 142.52 ( 122.55 ) 157.79 ( 135.67 ) 141.93 ( 122.04 ) 156.62 ( 134.66 ) 141.39 ( 121.57 ) 155.53 ( 133.73 )
51.0 142.80 ( 122.79 ) 158.10 ( 135.94 ) 142.21 ( 122.28 ) 156.92 ( 134.93 ) 141.67 ( 121.81 ) 155.83 ( 133.99 )
51.1 143.08 ( 123.03 ) 158.41 ( 136.21 ) 142.49 ( 122.52 ) 157.23 ( 135.19 ) 141.94 ( 122.05 ) 156.14 ( 134.26 )
51.2 143.36 ( 123.27 ) 158.72 ( 136.47 ) 142.77 ( 122.76 ) 157.54 ( 135.46 ) 142.22 ( 122.29 ) 156.44 ( 134.52 )
51.3 143.64 ( 123.51 ) 159.03 ( 136.74 ) 143.05 ( 123.00 ) 157.85 ( 135.72 ) 142.50 ( 122.53 ) 156.75 ( 134.78 )
51.4 143.92 ( 123.75 ) 159.34 ( 137.01 ) 143.33 ( 123.24 ) 158.15 ( 135.99 ) 142.78 ( 122.77 ) 157.06 ( 135.04 )
51.5 144.20 ( 123.99 ) 159.65 ( 137.27 ) 143.61 ( 123.48 ) 158.46 ( 136.25 ) 143.06 ( 123.01 ) 157.36 ( 135.31 )
51.6 144.23 ( 124.02 ) 159.66 ( 137.28 ) 143.88 ( 123.72 ) 158.77 ( 136.52 ) 143.33 ( 123.24 ) 157.67 ( 135.57 )
51.7 144.26 ( 124.04 ) 159.67 ( 137.29 ) 144.16 ( 123.96 ) 159.08 ( 136.78 ) 143.61 ( 123.48 ) 157.97 ( 135.83 )
51.8 144.29 ( 124.07 ) 159.68 ( 137.30 ) 144.44 ( 124.20 ) 159.38 ( 137.05 ) 143.89 ( 123.72 ) 158.28 ( 136.09 )
51.9 144.32 ( 124.10 ) 159.70 ( 137.31 ) 144.72 ( 124.44 ) 159.69 ( 137.31 ) 144.17 ( 123.96 ) 158.58 ( 136.36 )
52.0 144.36 ( 124.12 ) 159.71 ( 137.32 ) 145.00 ( 124.68 ) 160.00 ( 137.58 ) 144.44 ( 124.20 ) 158.89 ( 136.62 )
52.1 144.39 ( 124.15 ) 159.72 ( 137.33 ) 145.28 ( 124.92 ) 160.31 ( 137.84 ) 144.72 ( 124.44 ) 159.19 ( 136.88 )
52.2 144.42 ( 124.18 ) 159.73 ( 137.34 ) 145.56 ( 125.16 ) 160.62 ( 138.10 ) 145.00 ( 124.68 ) 159.50 ( 137.15 )
52.3 144.45 ( 124.20 ) 159.74 ( 137.35 ) 145.84 ( 125.40 ) 160.92 ( 138.37 ) 145.28 ( 124.92 ) 159.81 ( 137.41 )
52.4 144.48 ( 124.23 ) 159.75 ( 137.36 ) 146.12 ( 125.64 ) 161.23 ( 138.63 ) 145.56 ( 125.16 ) 160.11 ( 137.67 )
52.5 144.51 ( 124.26 ) 159.76 ( 137.37 ) 146.39 ( 125.88 ) 161.54 ( 138.90 ) 145.83 ( 125.39 ) 160.42 ( 137.93 )
52.6 144.54 ( 124.28 ) 159.78 ( 137.38 ) 146.67 ( 126.12 ) 161.85 ( 139.16 ) 146.11 ( 125.63 ) 160.72 ( 138.20 )
52.7 144.57 ( 124.31 ) 159.79 ( 137.39 ) 146.95 ( 126.36 ) 162.15 ( 139.43 ) 146.39 ( 125.87 ) 161.03 ( 138.46 )
52.8 144.60 ( 124.34 ) 159.80 ( 137.40 ) 147.23 ( 126.60 ) 162.46 ( 139.69 ) 146.67 ( 126.11 ) 161.33 ( 138.72 )
52.9 144.64 ( 124.36 ) 159.81 ( 137.41 ) 147.51 ( 126.84 ) 162.77 ( 139.96 ) 146.94 ( 126.35 ) 161.64 ( 138.98 )
53.0 144.67 ( 124.39 ) 159.82 ( 137.42 ) 147.79 ( 127.08 ) 163.08 ( 140.22 ) 147.22 ( 126.59 ) 161.94 ( 139.25 )
53.1 144.70 ( 124.42 ) 159.83 ( 137.43 ) 148.07 ( 127.31 ) 163.38 ( 140.49 ) 147.50 ( 126.83 ) 162.25 ( 139.51 )
53.2 144.73 ( 124.44 ) 159.85 ( 137.44 ) 148.35 ( 127.55 ) 163.69 ( 140.75 ) 147.78 ( 127.07 ) 162.56 ( 139.77 )
53.3 144.76 ( 124.47 ) 159.86 ( 137.45 ) 148.63 ( 127.79 ) 164.00 ( 141.01 ) 148.06 ( 127.30 ) 162.86 ( 140.04 )
53.4 144.79 ( 124.50 ) 159.87 ( 137.46 ) 148.90 ( 128.03 ) 164.31 ( 141.28 ) 148.33 ( 127.54 ) 163.17 ( 140.30 )
53.5 144.82 ( 124.52 ) 159.88 ( 137.47 ) 149.18 ( 128.27 ) 164.62 ( 141.54 ) 148.61 ( 127.78 ) 163.47 ( 140.56 )
53.6 144.85 ( 124.55 ) 159.89 ( 137.48 ) 149.36 ( 128.43 ) 164.80 ( 141.71 ) 148.89 ( 128.02 ) 163.78 ( 140.82 )
53.7 144.88 ( 124.58 ) 159.90 ( 137.49 ) 149.39 ( 128.46 ) 164.82 ( 141.72 ) 149.17 ( 128.26 ) 164.08 ( 141.09 )
53.8 144.92 ( 124.60 ) 159.91 ( 137.50 ) 149.42 ( 128.48 ) 164.83 ( 141.73 ) 149.44 ( 128.50 ) 164.39 ( 141.35 )
53.9 144.95 ( 124.63 ) 159.93 ( 137.51 ) 149.46 ( 128.51 ) 164.84 ( 141.74 ) 149.72 ( 128.74 ) 164.69 ( 141.61 )
54.0 144.98 ( 124.66 ) 159.94 ( 137.52 ) 149.49 ( 128.54 ) 164.85 ( 141.75 ) 150.00 ( 128.98 ) 165.00 ( 141.87 )
54.1 145.01 ( 124.69 ) 159.95 ( 137.53 ) 149.52 ( 128.56 ) 164.86 ( 141.76 ) 150.28 ( 129.22 ) 165.31 ( 142.14 )
54.2 145.04 ( 124.71 ) 159.96 ( 137.54 ) 149.55 ( 128.59 ) 164.87 ( 141.77 ) 150.56 ( 129.45 ) 165.61 ( 142.40 )
54.3 145.07 ( 124.74 ) 159.97 ( 137.55 ) 149.58 ( 128.62 ) 164.88 ( 141.78 ) 150.83 ( 129.69 ) 165.92 ( 142.66 )
54.4 145.10 ( 124.77 ) 159.98 ( 137.56 ) 149.61 ( 128.64 ) 164.90 ( 141.78 ) 151.11 ( 129.93 ) 166.22 ( 142.93 )
54.5 145.13 ( 124.79 ) 159.99 ( 137.57 ) 149.64 ( 128.67 ) 164.91 ( 141.79 ) 151.39 ( 130.17 ) 166.53 ( 143.19 )
54.6 145.16 ( 124.82 ) 160.01 ( 137.58 ) 149.67 ( 128.69 ) 164.92 ( 141.80 ) 151.67 ( 130.41 ) 166.83 ( 143.45 )
54.7 145.20 ( 124.85 ) 160.02 ( 137.59 ) 149.70 ( 128.72 ) 164.93 ( 141.81 ) 151.94 ( 130.65 ) 167.14 ( 143.71 )
54.8 145.23 ( 124.87 ) 160.03 ( 137.60 ) 149.73 ( 128.75 ) 164.94 ( 141.82 ) 152.22 ( 130.89 ) 167.44 ( 143.98 )
54.9 145.26 ( 124.90 ) 160.04 ( 137.61 ) 149.77 ( 128.77 ) 164.95 ( 141.83 ) 152.50 ( 131.13 ) 167.75 ( 144.24 )

1-106 FAN-2209 201709


SELECTION DATA

Table 39. Outdoor Unit Capacity (JTOR500~540VAE(U,F,R)BS1) with Total Horsepower of Combined Indoor Unit (6)
Total Outdoor Unit Capacity: kW (×1000kcal/h)
RAS-50FSXNS
JTOR500VAE(U,F,R)BS1 RAS-52FSXNS
JTOR520VAE(U,F,R)BS1 RAS-54FSXNS
JTOR540VAE(U,F,R)BS1
Cooling Heating Cooling Heating Cooling Heating
55.0 145.29 ( 124.93 ) 160.05 ( 137.62 ) 149.80 ( 128.80 ) 164.96 ( 141.84 ) 152.78 ( 131.37 ) 168.06 ( 144.50 )
55.1 145.32 ( 124.95 ) 160.06 ( 137.63 ) 149.83 ( 128.83 ) 164.98 ( 141.85 ) 153.06 ( 131.60 ) 168.36 ( 144.76 )
55.2 145.35 ( 124.98 ) 160.07 ( 137.64 ) 149.86 ( 128.85 ) 164.99 ( 141.86 ) 153.33 ( 131.84 ) 168.67 ( 145.03 )
55.3 145.38 ( 125.01 ) 160.09 ( 137.65 ) 149.89 ( 128.88 ) 165.00 ( 141.87 ) 153.61 ( 132.08 ) 168.97 ( 145.29 )
55.4 145.41 ( 125.03 ) 160.10 ( 137.66 ) 149.92 ( 128.91 ) 165.01 ( 141.88 ) 153.89 ( 132.32 ) 169.28 ( 145.55 )
55.5 145.44 ( 125.06 ) 160.11 ( 137.67 ) 149.95 ( 128.93 ) 165.02 ( 141.89 ) 154.17 ( 132.56 ) 169.58 ( 145.82 )
55.6 145.48 ( 125.09 ) 160.12 ( 137.68 ) 149.98 ( 128.96 ) 165.03 ( 141.90 ) 154.44 ( 132.80 ) 169.89 ( 146.08 )
55.7 145.51 ( 125.11 ) 160.13 ( 137.69 ) 150.01 ( 128.99 ) 165.04 ( 141.91 ) 154.52 ( 132.87 ) 169.96 ( 146.14 )
55.8 145.54 ( 125.14 ) 160.14 ( 137.70 ) 150.04 ( 129.01 ) 165.06 ( 141.92 ) 154.56 ( 132.89 ) 169.97 ( 146.15 )
55.9 145.57 ( 125.17 ) 160.16 ( 137.71 ) 150.08 ( 129.04 ) 165.07 ( 141.93 ) 154.59 ( 132.92 ) 169.98 ( 146.16 )
56.0 145.60 ( 125.19 ) 160.17 ( 137.72 ) 150.11 ( 129.07 ) 165.08 ( 141.94 ) 154.62 ( 132.95 ) 169.99 ( 146.17 )
56.1 145.63 ( 125.22 ) 160.18 ( 137.73 ) 150.14 ( 129.09 ) 165.09 ( 141.95 ) 154.65 ( 132.97 ) 170.00 ( 146.18 )
56.2 145.66 ( 125.25 ) 160.19 ( 137.74 ) 150.17 ( 129.12 ) 165.10 ( 141.96 ) 154.68 ( 133.00 ) 170.02 ( 146.19 )
56.3 145.69 ( 125.27 ) 160.20 ( 137.75 ) 150.20 ( 129.15 ) 165.11 ( 141.97 ) 154.71 ( 133.03 ) 170.03 ( 146.20 )
56.4 145.72 ( 125.30 ) 160.21 ( 137.76 ) 150.23 ( 129.17 ) 165.12 ( 141.98 ) 154.74 ( 133.05 ) 170.04 ( 146.21 )
56.5 145.76 ( 125.33 ) 160.22 ( 137.77 ) 150.26 ( 129.20 ) 165.14 ( 141.99 ) 154.77 ( 133.08 ) 170.05 ( 146.22 )
56.6 145.79 ( 125.35 ) 160.24 ( 137.78 ) 150.29 ( 129.23 ) 165.15 ( 142.00 ) 154.80 ( 133.11 ) 170.06 ( 146.23 )
56.7 145.82 ( 125.38 ) 160.25 ( 137.79 ) 150.32 ( 129.25 ) 165.16 ( 142.01 ) 154.83 ( 133.13 ) 170.07 ( 146.24 )
56.8 145.85 ( 125.41 ) 160.26 ( 137.80 ) 150.35 ( 129.28 ) 165.17 ( 142.02 ) 154.86 ( 133.16 ) 170.08 ( 146.25 )
56.9 145.88 ( 125.43 ) 160.27 ( 137.81 ) 150.38 ( 129.31 ) 165.18 ( 142.03 ) 154.90 ( 133.19 ) 170.09 ( 146.26 )
57.0 145.91 ( 125.46 ) 160.28 ( 137.82 ) 150.42 ( 129.33 ) 165.19 ( 142.04 ) 154.93 ( 133.21 ) 170.11 ( 146.26 )
57.1 145.94 ( 125.49 ) 160.29 ( 137.83 ) 150.45 ( 129.36 ) 165.20 ( 142.05 ) 154.96 ( 133.24 ) 170.12 ( 146.27 )
57.2 145.97 ( 125.51 ) 160.30 ( 137.84 ) 150.48 ( 129.39 ) 165.21 ( 142.06 ) 154.99 ( 133.27 ) 170.13 ( 146.28 )
57.3 146.00 ( 125.54 ) 160.32 ( 137.85 ) 150.51 ( 129.41 ) 165.23 ( 142.07 ) 155.02 ( 133.29 ) 170.14 ( 146.29 )
57.4 146.04 ( 125.57 ) 160.33 ( 137.86 ) 150.54 ( 129.44 ) 165.24 ( 142.08 ) 155.05 ( 133.32 ) 170.15 ( 146.30 )
57.5 146.07 ( 125.59 ) 160.34 ( 137.87 ) 150.57 ( 129.47 ) 165.25 ( 142.09 ) 155.08 ( 133.35 ) 170.16 ( 146.31 )
57.6 146.10 ( 125.62 ) 160.35 ( 137.88 ) 150.60 ( 129.49 ) 165.26 ( 142.10 ) 155.11 ( 133.37 ) 170.17 ( 146.32 )
57.7 146.13 ( 125.65 ) 160.36 ( 137.89 ) 150.63 ( 129.52 ) 165.27 ( 142.11 ) 155.14 ( 133.40 ) 170.19 ( 146.33 )
57.8 146.16 ( 125.67 ) 160.37 ( 137.90 ) 150.66 ( 129.55 ) 165.28 ( 142.12 ) 155.17 ( 133.42 ) 170.20 ( 146.34 )
57.9 146.19 ( 125.70 ) 160.38 ( 137.91 ) 150.69 ( 129.57 ) 165.29 ( 142.13 ) 155.20 ( 133.45 ) 170.21 ( 146.35 )
58.0 146.22 ( 125.73 ) 160.40 ( 137.92 ) 150.73 ( 129.60 ) 165.31 ( 142.14 ) 155.23 ( 133.48 ) 170.22 ( 146.36 )
58.1 146.25 ( 125.76 ) 160.41 ( 137.93 ) 150.76 ( 129.63 ) 165.32 ( 142.15 ) 155.27 ( 133.50 ) 170.23 ( 146.37 )
58.2 146.28 ( 125.78 ) 160.42 ( 137.94 ) 150.79 ( 129.65 ) 165.33 ( 142.16 ) 155.30 ( 133.53 ) 170.24 ( 146.38 )
58.3 146.32 ( 125.81 ) 160.43 ( 137.95 ) 150.82 ( 129.68 ) 165.34 ( 142.17 ) 155.33 ( 133.56 ) 170.25 ( 146.39 )
58.4 146.35 ( 125.84 ) 160.44 ( 137.96 ) 150.85 ( 129.71 ) 165.35 ( 142.18 ) 155.36 ( 133.58 ) 170.26 ( 146.40 )
58.5 146.38 ( 125.86 ) 160.45 ( 137.97 ) 150.88 ( 129.73 ) 165.36 ( 142.19 ) 155.39 ( 133.61 ) 170.28 ( 146.41 )
58.6 146.41 ( 125.89 ) 160.47 ( 137.98 ) 150.91 ( 129.76 ) 165.37 ( 142.20 ) 155.42 ( 133.64 ) 170.29 ( 146.42 )
58.7 146.44 ( 125.92 ) 160.48 ( 137.99 ) 150.94 ( 129.79 ) 165.39 ( 142.21 ) 155.45 ( 133.66 ) 170.30 ( 146.43 )
58.8 146.47 ( 125.94 ) 160.49 ( 137.99 ) 150.97 ( 129.81 ) 165.40 ( 142.22 ) 155.48 ( 133.69 ) 170.31 ( 146.44 )
58.9 146.50 ( 125.97 ) 160.50 ( 138.00 ) 151.00 ( 129.84 ) 165.41 ( 142.23 ) 155.51 ( 133.72 ) 170.32 ( 146.45 )
59.0 146.53 ( 126.00 ) 160.51 ( 138.01 ) 151.04 ( 129.87 ) 165.42 ( 142.24 ) 155.54 ( 133.74 ) 170.33 ( 146.46 )
59.1 146.56 ( 126.02 ) 160.52 ( 138.02 ) 151.07 ( 129.89 ) 165.43 ( 142.25 ) 155.57 ( 133.77 ) 170.34 ( 146.47 )
59.2 146.60 ( 126.05 ) 160.53 ( 138.03 ) 151.10 ( 129.92 ) 165.44 ( 142.26 ) 155.60 ( 133.80 ) 170.36 ( 146.48 )
59.3 146.63 ( 126.08 ) 160.55 ( 138.04 ) 151.13 ( 129.95 ) 165.45 ( 142.26 ) 155.64 ( 133.82 ) 170.37 ( 146.49 )
59.4 146.66 ( 126.10 ) 160.56 ( 138.05 ) 151.16 ( 129.97 ) 165.47 ( 142.27 ) 155.67 ( 133.85 ) 170.38 ( 146.50 )
59.5 146.69 ( 126.13 ) 160.57 ( 138.06 ) 151.19 ( 130.00 ) 165.48 ( 142.28 ) 155.70 ( 133.88 ) 170.39 ( 146.51 )
59.6 146.72 ( 126.16 ) 160.58 ( 138.07 ) 151.22 ( 130.03 ) 165.49 ( 142.29 ) 155.73 ( 133.90 ) 170.40 ( 146.52 )
59.7 146.75 ( 126.18 ) 160.59 ( 138.08 ) 151.25 ( 130.05 ) 165.50 ( 142.30 ) 155.76 ( 133.93 ) 170.41 ( 146.53 )
59.8 146.78 ( 126.21 ) 160.60 ( 138.09 ) 151.28 ( 130.08 ) 165.51 ( 142.31 ) 155.79 ( 133.96 ) 170.42 ( 146.54 )
59.9 146.81 ( 126.24 ) 160.61 ( 138.10 ) 151.31 ( 130.11 ) 165.52 ( 142.32 ) 155.82 ( 133.98 ) 170.43 ( 146.55 )
60.0 146.84 ( 126.26 ) 160.63 ( 138.11 ) 151.35 ( 130.13 ) 165.53 ( 142.33 ) 155.85 ( 134.01 ) 170.45 ( 146.56 )
60.1 146.88 ( 126.29 ) 160.64 ( 138.12 ) 151.38 ( 130.16 ) 165.55 ( 142.34 ) 155.88 ( 134.04 ) 170.46 ( 146.57 )
60.2 146.91 ( 126.32 ) 160.65 ( 138.13 ) 151.41 ( 130.19 ) 165.56 ( 142.35 ) 155.91 ( 134.06 ) 170.47 ( 146.58 )
60.3 146.94 ( 126.34 ) 160.66 ( 138.14 ) 151.44 ( 130.21 ) 165.57 ( 142.36 ) 155.94 ( 134.09 ) 170.48 ( 146.59 )
60.4 146.97 ( 126.37 ) 160.67 ( 138.15 ) 151.47 ( 130.24 ) 165.58 ( 142.37 ) 155.98 ( 134.11 ) 170.49 ( 146.60 )
60.5 147.00 ( 126.40 ) 160.68 ( 138.16 ) 151.50 ( 130.27 ) 165.59 ( 142.38 ) 156.01 ( 134.14 ) 170.50 ( 146.61 )
60.6 147.03 ( 126.42 ) 160.69 ( 138.17 ) 151.53 ( 130.29 ) 165.60 ( 142.39 ) 156.04 ( 134.17 ) 170.51 ( 146.62 )
60.7 147.06 ( 126.45 ) 160.71 ( 138.18 ) 151.56 ( 130.32 ) 165.61 ( 142.40 ) 156.07 ( 134.19 ) 170.52 ( 146.63 )
60.8 147.09 ( 126.48 ) 160.72 ( 138.19 ) 151.59 ( 130.35 ) 165.63 ( 142.41 ) 156.10 ( 134.22 ) 170.54 ( 146.63 )
60.9 147.12 ( 126.50 ) 160.73 ( 138.20 ) 151.62 ( 130.37 ) 165.64 ( 142.42 ) 156.13 ( 134.25 ) 170.55 ( 146.64 )

FAN-2209 201709 1-107


SELECTION DATA

Table 40. Outdoor Unit Capacity (JTOR500~540VAE(U,F,R)BS1) with Total Horsepower of Combined Indoor Unit (7)
Total Outdoor Unit Capacity: kW (×1000kcal/h)
RAS-50FSXNS
JTOR500VAE(U,F,R)BS1 RAS-52FSXNS
JTOR520VAE(U,F,R)BS1 RAS-54FSXNS
JTOR540VAE(U,F,R)BS1
Cooling Heating Cooling Heating Cooling Heating
61.0 147.16 ( 126.53 ) 160.74 ( 138.21 ) 151.66 ( 130.40 ) 165.65 ( 142.43 ) 156.16 ( 134.27 ) 170.56 ( 146.65 )
61.1 147.19 ( 126.56 ) 160.75 ( 138.22 ) 151.69 ( 130.43 ) 165.66 ( 142.44 ) 156.19 ( 134.30 ) 170.57 ( 146.66 )
61.2 147.22 ( 126.58 ) 160.76 ( 138.23 ) 151.72 ( 130.45 ) 165.67 ( 142.45 ) 156.22 ( 134.33 ) 170.58 ( 146.67 )
61.3 147.25 ( 126.61 ) 160.78 ( 138.24 ) 151.75 ( 130.48 ) 165.68 ( 142.46 ) 156.25 ( 134.35 ) 170.59 ( 146.68 )
61.4 147.28 ( 126.64 ) 160.79 ( 138.25 ) 151.78 ( 130.51 ) 165.69 ( 142.47 ) 156.28 ( 134.38 ) 170.60 ( 146.69 )
61.5 147.31 ( 126.66 ) 160.80 ( 138.26 ) 151.81 ( 130.53 ) 165.70 ( 142.48 ) 156.31 ( 134.41 ) 170.62 ( 146.70 )
61.6 147.34 ( 126.69 ) 160.81 ( 138.27 ) 151.84 ( 130.56 ) 165.72 ( 142.49 ) 156.35 ( 134.43 ) 170.63 ( 146.71 )
61.7 147.37 ( 126.72 ) 160.82 ( 138.28 ) 151.87 ( 130.59 ) 165.73 ( 142.50 ) 156.38 ( 134.46 ) 170.64 ( 146.72 )
61.8 147.40 ( 126.75 ) 160.83 ( 138.29 ) 151.90 ( 130.61 ) 165.74 ( 142.51 ) 156.41 ( 134.49 ) 170.65 ( 146.73 )
61.9 147.44 ( 126.77 ) 160.84 ( 138.30 ) 151.93 ( 130.64 ) 165.75 ( 142.52 ) 156.44 ( 134.51 ) 170.66 ( 146.74 )
62.0 147.47 ( 126.80 ) 160.86 ( 138.31 ) 151.96 ( 130.67 ) 165.76 ( 142.53 ) 156.47 ( 134.54 ) 170.67 ( 146.75 )
62.1 147.50 ( 126.83 ) 160.87 ( 138.32 ) 152.00 ( 130.69 ) 165.77 ( 142.54 ) 156.50 ( 134.57 ) 170.68 ( 146.76 )
62.2 147.53 ( 126.85 ) 160.88 ( 138.33 ) 152.03 ( 130.72 ) 165.78 ( 142.55 ) 156.53 ( 134.59 ) 170.69 ( 146.77 )
62.3 147.56 ( 126.88 ) 160.89 ( 138.34 ) 152.06 ( 130.75 ) 165.80 ( 142.56 ) 156.56 ( 134.62 ) 170.71 ( 146.78 )
62.4 147.59 ( 126.91 ) 160.90 ( 138.35 ) 152.09 ( 130.77 ) 165.81 ( 142.57 ) 156.59 ( 134.65 ) 170.72 ( 146.79 )
62.5 147.62 ( 126.93 ) 160.91 ( 138.36 ) 152.12 ( 130.80 ) 165.82 ( 142.58 ) 156.62 ( 134.67 ) 170.73 ( 146.80 )
62.6 147.65 ( 126.96 ) 160.92 ( 138.37 ) 152.15 ( 130.83 ) 165.83 ( 142.59 ) 156.65 ( 134.70 ) 170.74 ( 146.81 )
62.7 147.68 ( 126.99 ) 160.94 ( 138.38 ) 152.18 ( 130.85 ) 165.84 ( 142.60 ) 156.69 ( 134.73 ) 170.75 ( 146.82 )
62.8 147.72 ( 127.01 ) 160.95 ( 138.39 ) 152.21 ( 130.88 ) 165.85 ( 142.61 ) 156.72 ( 134.75 ) 170.76 ( 146.83 )
62.9 147.75 ( 127.04 ) 160.96 ( 138.40 ) 152.24 ( 130.91 ) 165.86 ( 142.62 ) 156.75 ( 134.78 ) 170.77 ( 146.84 )
63.0 147.78 ( 127.07 ) 160.97 ( 138.41 ) 152.27 ( 130.93 ) 165.88 ( 142.63 ) 156.78 ( 134.80 ) 170.79 ( 146.85 )
63.1 147.81 ( 127.09 ) 160.98 ( 138.42 ) 152.31 ( 130.96 ) 165.89 ( 142.64 ) 156.81 ( 134.83 ) 170.80 ( 146.86 )
63.2 147.84 ( 127.12 ) 160.99 ( 138.43 ) 152.34 ( 130.99 ) 165.90 ( 142.65 ) 156.84 ( 134.86 ) 170.81 ( 146.87 )
63.3 147.87 ( 127.15 ) 161.00 ( 138.44 ) 152.37 ( 131.01 ) 165.91 ( 142.66 ) 156.87 ( 134.88 ) 170.82 ( 146.88 )
63.4 147.90 ( 127.17 ) 161.02 ( 138.45 ) 152.40 ( 131.04 ) 165.92 ( 142.67 ) 156.90 ( 134.91 ) 170.83 ( 146.89 )
63.5 147.93 ( 127.20 ) 161.03 ( 138.46 ) 152.43 ( 131.07 ) 165.93 ( 142.68 ) 156.93 ( 134.94 ) 170.84 ( 146.90 )
63.6 147.96 ( 127.23 ) 161.04 ( 138.47 ) 152.46 ( 131.09 ) 165.94 ( 142.69 ) 156.96 ( 134.96 ) 170.85 ( 146.91 )
63.7 148.00 ( 127.25 ) 161.05 ( 138.48 ) 152.49 ( 131.12 ) 165.96 ( 142.70 ) 156.99 ( 134.99 ) 170.86 ( 146.92 )
63.8 148.03 ( 127.28 ) 161.06 ( 138.49 ) 152.52 ( 131.15 ) 165.97 ( 142.71 ) 157.02 ( 135.02 ) 170.88 ( 146.93 )
63.9 148.06 ( 127.31 ) 161.07 ( 138.50 ) 152.55 ( 131.17 ) 165.98 ( 142.72 ) 157.06 ( 135.04 ) 170.89 ( 146.94 )
64.0 148.09 ( 127.33 ) 161.09 ( 138.51 ) 152.58 ( 131.20 ) 165.99 ( 142.73 ) 157.09 ( 135.07 ) 170.90 ( 146.95 )
64.1 148.12 ( 127.36 ) 161.10 ( 138.52 ) 152.62 ( 131.23 ) 166.00 ( 142.74 ) 157.12 ( 135.10 ) 170.91 ( 146.96 )
64.2 148.15 ( 127.39 ) 161.11 ( 138.53 ) 152.65 ( 131.25 ) 166.01 ( 142.75 ) 157.15 ( 135.12 ) 170.92 ( 146.97 )
64.3 148.18 ( 127.41 ) 161.12 ( 138.54 ) 152.68 ( 131.28 ) 166.02 ( 142.75 ) 157.18 ( 135.15 ) 170.93 ( 146.98 )
64.4 148.21 ( 127.44 ) 161.13 ( 138.55 ) 152.71 ( 131.31 ) 166.04 ( 142.76 ) 157.21 ( 135.18 ) 170.94 ( 146.99 )
64.5 148.24 ( 127.47 ) 161.14 ( 138.56 ) 152.74 ( 131.33 ) 166.05 ( 142.77 ) 157.24 ( 135.20 ) 170.95 ( 146.99 )
64.6 148.28 ( 127.49 ) 161.15 ( 138.57 ) 152.77 ( 131.36 ) 166.06 ( 142.78 ) 157.27 ( 135.23 ) 170.97 ( 147.00 )
64.7 148.31 ( 127.52 ) 161.17 ( 138.58 ) 152.80 ( 131.39 ) 166.07 ( 142.79 ) 157.30 ( 135.26 ) 170.98 ( 147.01 )
64.8 148.34 ( 127.55 ) 161.18 ( 138.59 ) 152.83 ( 131.41 ) 166.08 ( 142.80 ) 157.33 ( 135.28 ) 170.99 ( 147.02 )
64.9 148.37 ( 127.57 ) 161.19 ( 138.60 ) 152.86 ( 131.44 ) 166.09 ( 142.81 ) 157.36 ( 135.31 ) 171.00 ( 147.03 )
65.0 148.40 ( 127.60 ) 161.20 ( 138.61 ) 152.89 ( 131.47 ) 166.10 ( 142.82 ) 157.40 ( 135.34 ) 171.01 ( 147.04 )
65.1 152.93 ( 131.49 ) 166.12 ( 142.83 ) 157.43 ( 135.36 ) 171.02 ( 147.05 )
65.2 152.96 ( 131.52 ) 166.13 ( 142.84 ) 157.46 ( 135.39 ) 171.03 ( 147.06 )
65.3 152.99 ( 131.55 ) 166.14 ( 142.85 ) 157.49 ( 135.42 ) 171.05 ( 147.07 )
65.4 153.02 ( 131.57 ) 166.15 ( 142.86 ) 157.52 ( 135.44 ) 171.06 ( 147.08 )
65.5 153.05 ( 131.60 ) 166.16 ( 142.87 ) 157.55 ( 135.47 ) 171.07 ( 147.09 )
65.6 153.08 ( 131.63 ) 166.17 ( 142.88 ) 157.58 ( 135.49 ) 171.08 ( 147.10 )
65.7 153.11 ( 131.65 ) 166.18 ( 142.89 ) 157.61 ( 135.52 ) 171.09 ( 147.11 )
65.8 153.14 ( 131.68 ) 166.19 ( 142.90 ) 157.64 ( 135.55 ) 171.10 ( 147.12 )
65.9 153.17 ( 131.71 ) 166.21 ( 142.91 ) 157.67 ( 135.57 ) 171.11 ( 147.13 )
66.0 _ 153.20 ( 131.73 ) 166.22 ( 142.92 ) 157.70 ( 135.60 ) 171.12 ( 147.14 )
66.1 153.24 ( 131.76 ) 166.23 ( 142.93 ) 157.73 ( 135.63 ) 171.14 ( 147.15 )
66.2 153.27 ( 131.79 ) 166.24 ( 142.94 ) 157.77 ( 135.65 ) 171.15 ( 147.16 )
66.3 153.30 ( 131.81 ) 166.25 ( 142.95 ) 157.80 ( 135.68 ) 171.16 ( 147.17 )
66.4 153.33 ( 131.84 ) 166.26 ( 142.96 ) 157.83 ( 135.71 ) 171.17 ( 147.18 )
66.5 153.36 ( 131.87 ) 166.27 ( 142.97 ) 157.86 ( 135.73 ) 171.18 ( 147.19 )
66.6 153.39 ( 131.89 ) 166.29 ( 142.98 ) 157.89 ( 135.76 ) 171.19 ( 147.20 )
66.7 153.42 ( 131.92 ) 166.30 ( 142.99 ) 157.92 ( 135.79 ) 171.20 ( 147.21 )
66.8 153.45 ( 131.95 ) 166.31 ( 143.00 ) 157.95 ( 135.81 ) 171.22 ( 147.22 )
66.9 153.48 ( 131.97 ) 166.32 ( 143.01 ) 157.98 ( 135.84 ) 171.23 ( 147.23 )

1-108 FAN-2209 201709


SELECTION DATA

Table 41. Outdoor Unit Capacity (JTOR500~540VAE(U,F,R)BS1) with Total Horsepower of Combined Indoor Unit (8)
Total Outdoor Unit Capacity: kW (×1000kcal/h)
RAS-50FSXNS
JTOR500VAE(U,F,R)BS1 RAS-52FSXNS
JTOR520VAE(U,F,R)BS1 RAS-54FSXNS
JTOR540VAE(U,F,R)BS1
Cooling Heating Cooling Heating Cooling Heating
67.0 153.51 ( 132.00 ) 166.33 ( 143.02 ) 158.01 ( 135.87 ) 171.24 ( 147.24 )
67.1 153.55 ( 132.03 ) 166.34 ( 143.03 ) 158.04 ( 135.89 ) 171.25 ( 147.25 )
67.2 153.58 ( 132.05 ) 166.35 ( 143.04 ) 158.07 ( 135.92 ) 171.26 ( 147.26 )
67.3 153.61 ( 132.08 ) 166.37 ( 143.05 ) 158.10 ( 135.95 ) 171.27 ( 147.27 )
67.4 153.64 ( 132.10 ) 166.38 ( 143.06 ) 158.14 ( 135.97 ) 171.28 ( 147.28 )
67.5 153.67 ( 132.13 ) 166.39 ( 143.07 ) 158.17 ( 136.00 ) 171.29 ( 147.29 )
67.6 153.70 ( 132.16 ) 166.40 ( 143.08 ) 158.20 ( 136.03 ) 171.31 ( 147.30 )
67.7 158.23 ( 136.05 ) 171.32 ( 147.31 )
67.8 158.26 ( 136.08 ) 171.33 ( 147.32 )
67.9 158.29 ( 136.11 ) 171.34 ( 147.33 )
68.0 158.32 ( 136.13 ) 171.35 ( 147.34 )
68.1 158.35 ( 136.16 ) 171.36 ( 147.35 )
68.2 158.38 ( 136.18 ) 171.37 ( 147.35 )
68.3 158.41 ( 136.21 ) 171.38 ( 147.36 )
68.4 158.44 ( 136.24 ) 171.40 ( 147.37 )
68.5 158.48 ( 136.26 ) 171.41 ( 147.38 )
68.6 _ 158.51 ( 136.29 ) 171.42 ( 147.39 )
68.7 158.54 ( 136.32 ) 171.43 ( 147.40 )
68.8 158.57 ( 136.34 ) 171.44 ( 147.41 )
68.9 158.60 ( 136.37 ) 171.45 ( 147.42 )
_
69.0 158.63 ( 136.40 ) 171.46 ( 147.43 )
69.1 158.66 ( 136.42 ) 171.48 ( 147.44 )
69.2 158.69 ( 136.45 ) 171.49 ( 147.45 )
69.3 158.72 ( 136.48 ) 171.50 ( 147.46 )
69.4 158.75 ( 136.50 ) 171.51 ( 147.47 )
69.5 158.78 ( 136.53 ) 171.52 ( 147.48 )
69.6 158.81 ( 136.56 ) 171.53 ( 147.49 )
69.7 158.85 ( 136.58 ) 171.54 ( 147.50 )
69.8 158.88 ( 136.61 ) 171.55 ( 147.51 )
69.9 158.91 ( 136.64 ) 171.57 ( 147.52 )
70.0 158.94 ( 136.66 ) 171.58 ( 147.53 )
70.1 158.97 ( 136.69 ) 171.59 ( 147.54 )
70.2 159.00 ( 136.72 ) 171.60 ( 147.55 )

FAN-2209 201709 1-109


SELECTION DATA

6.3 Outdoor Unit Capacity According to Temperature Condition and Connected IDU Capacity
Ratio (Part Load Data)

Refer to the Appendix for the detailed part load.

6.4 Correction Factor According to Piping Length

< Cooling Capacity >


Correction Factor for Cooling Capacity According to Piping Length
The cooling capacity should be corrected according to the following formula:
CCA=CCxF
CCA: Actual Corrected Cooling Capacity
CC: Cooling Capacity in the Performance Table
F: Correction Factor Based on the Equivalent Piping Length
The correction factors are shown in the following figure.
Equivalent Piping Length for
• One 90o Elbow is 0.5m.
• One 180o Bend is 1.5m.
• One Multi-Kit is 0.5m.

H: Vertical Distance Between Indoor Unit and


Outdoor Unit Indoor Unit
L
Outdoor Unit in Meters
Outdoor EL: Equivalent Total Distance Between Indoor Unit and
Unit
L Indoor Outdoor Unit in Meters (Equivalent One-Way Piping Length)
Unit -H
+H H>0: Position of Outdoor Unit Higher Than Position of Indoor Unit
L: Actual One-Way Piping Length Between Indoor Unit and
Outdoor Unit in Meters
NOTE:
If EL is more than 100m, increase both Liquid Pipe and Gas Pipe by 1 size.

Outdoor Unit: JTOR080 ~ 180VPE(U,F,R)BS1

1-110 FAN-2209 201709


SELECTION DATA

Outdoor Unit: JTOR200 ~ 240VPE(U,F,R)BS1


JTOR260 ~ 300VAE(U,F,R)BS1

Outdoor Unit: JTOR320 ~ 440VAE(U,F,R)BS1

Outdoor Unit: JTOR460 ~ 540VAE(U,F,R)BS1

FAN-2209 201709 1-111


SELECTION DATA

< Heating Capacity >


Correction Factor for Heating Capacity According to Piping Length
The heating capacity should be corrected according to the following formula:
HCA=HCxF
HCA: Actual Corrected Heating Capacity
HC: Heating Capacity in the Performance Table
F: Correction Factor Based on the Equivalent Piping Length
The correction factors are shown in the following figure.
Equivalent Piping Length for
• One 90o Elbow is 0.5m.
• One 180o Bend is 1.5m.
• One Multi-Kit is 0.5m.
H: Vertical Distance Between Indoor Unit and
Outdoor Unit Indoor Unit
L
Outdoor Unit in Meters
Outdoor EL: Equivalent Total Distance Between Indoor Unit and
Unit
L Indoor Outdoor Unit in Meters (Equivalent One-Way Piping Length)
Unit -H
+H H>0: Position of Outdoor Unit Higher Than Position of Indoor Unit
L: Actual One-Way Piping Length Between Indoor Unit and
Outdoor Unit in Meters

NOTE:
If EL is more than 100m, increase both Liquid Pipe and Gas Pipe by 1 size.

Outdoor Unit: JTOR080 ~ 180VPE(U,F,R)BS1

Outdoor Unit: JTOR200 ~ 240VPE(U,F,R)BS1


JTOR260 ~ 300VAE(U,F,R)BS1

1-112 FAN-2209 201709


SELECTION DATA

Outdoor Unit: JTOR320 ~ 440VAE(U,F,R)BS1

Outdoor Unit: JTOR460 ~ 540VAE(U,F,R)BS1

6.5 Correction Factor According to Defrosting Operation


The heating capacity in the preceding paragraph, excludes the condition of the frost or the defrosting
operation period.
In consideration of the frost or the defrosting operation, the heating capacity is corrected by the equation
below.

Corrected Heating Capacity = Correction Factor x Heating Capacity


Outdoor Inlet Air Temp. (oC DB)
-7 -5 -3 0 3 5 7
(Humidity=85% RH)
Correction Factor 0.95 0.93 0.88 0.85 0.87 0.90 1.0

NOTE:
The correction factor is not available for the special condition like a snowfall or a operation in a transitional
period.

FAN-2209 201709 1-113


SELECTION DATA

6.6 Correction Factor According to Altitude


The capacity is impacted by the altitude.
Corrected Capacity = Correction Factor × Capacity

m 0 300 600 900 1200 1500 1800 2000


Altitude
(ft) (0) (984) (1,969) (2,953) (3,937) (4,921) (5,906) (6,562)
Correction
1.00 0.97 0.93 0.90 0.87 0.84 0.81 0.81
Factor

m 2100 2400 2700 3000 3300 3600 3900 4000


Altitude
(ft) (6,890) (7,874) (8,858) (9,843) (10,827) (11,811) (12,795) (13,123)
Correction
0.78 0.75 0.72 0.70 0.67 0.64 0.62 0.61
Factor

1-114 FAN-2209 201709


ELECTRICAL DATA

7. Electrical Data

< 460V/60Hz >


Cooling Heating
Unit Main Power Applicable Voltage Maximum
Model STC Operation Operation
Current
VOL PH HZ Maximum Minimum RNC IPT RNC IPT
JTOR080VPEUBS1 8 6.0 4.30 6.5 4.68 14.0
JTOR100VPEUBS1 8 8.2 5.88 8.6 6.16 19.0
JTOR120VPEUBS1 8 9.5 6.84 10.6 7.60 21.0
JTOR140VPEUBS1 8 13.4 9.63 16.0 11.46 26.0
JTOR160VPEUBS1 19 14.1 10.09 17.0 12.19 29.5
JTOR180VPEUBS1 19 16.6 11.89 19.1 13.68 33.5
JTOR200VPEUBS1 19 21.1 15.12 22.4 16.08 39.5
JTOR220VPEUBS1 19 22.9 16.40 28.0 20.10 40.0
JTOR240VPEUBS1 19 26.3 18.87 28.2 20.19 47.5
JTOR260VAEUBS1 30 22.7 16.27 26.6 19.06 47.0
JTOR280VAEUBS1 55 23.0 16.46 29.2 20.91 50.5
JTOR300VAEUBS1 55 27.0 19.38 30.6 21.96 54.5
460 3~ 60 500 414
JTOR320VAEUBS1 55 30.0 21.52 34.3 24.62 59.5
JTOR340VAEUBS1 75 30.7 21.98 36.1 25.86 63.0
JTOR360VAEUBS1 75 33.2 23.78 38.1 27.35 67.0
JTOR380VAEUBS1 55 39.0 27.98 40.7 29.20 73.5
JTOR400VAEUBS1 75 39.9 28.58 46.6 33.44 73.5
JTOR420VAEUBS1 75 43.6 31.26 47.2 33.84 81.0
JTOR440VAEUBS1 75 44.9 32.20 57.6 41.29 80.0
JTOR460VAEUBS1 75 48.7 34.96 55.1 39.48 87.5
JTOR480VAEUBS1 75 53.5 38.39 54.3 38.93 94.5
JTOR500VAEUBS1 95 46.6 33.41 52.7 37.80 93.0
JTOR520VAEUBS1 115 47.2 33.87 53.8 38.55 96.5
JTOR540VAEUBS1 115 49.7 35.67 55.2 39.56 100.5

VOL: Rated Unit Power Supply Voltage (Plated)(V) RNC: Running Current (A)
HZ: Frequency (Hz) IPT: Input (kW)
STC: Starting Current (A)

NOTES:
1. The above compressor data is based on 100% capacity combination of the indoor units at rated operating frequency.
2. The above performance data is based on the equivalent piping length of each unit horsepower and 0m piping lift.
3. These data are based on the same conditions as the nominal heating and cooling capacities.
4. The compressor is started by an inverter, resulting in extremely low starting current.

FAN-2209 201709 1-115


ELECTRICAL DATA

< 380V/60Hz >


Cooling Heating
Unit Main Power Applicable Voltage Maximum
Model STC Operation Operation
Current
VOL PH HZ Maximum Minimum RNC IPT RNC IPT
JTOR080VPEFBS1 9 7.3 4.30 7.9 4.68 15.5
JTOR100VPEFBS1 9 9.9 5.88 10.4 6.16 21.5
JTOR120VPEFBS1 9 11.5 6.84 12.8 7.60 24.0
JTOR140VPEFBS1 9 16.3 9.63 19.3 11.46 29.5
JTOR160VPEFBS1 20 17.0 10.09 20.6 12.19 33.0
JTOR180VPEFBS1 20 20.1 11.89 23.1 13.68 37.5
JTOR200VPEFBS1 20 25.5 15.12 27.2 16.08 44.5
JTOR220VPEFBS1 20 27.7 16.40 33.9 20.10 45.0
JTOR240VPEFBS1 20 31.9 18.87 34.1 20.19 53.0
JTOR260VAEFBS1 17 27.5 16.27 32.2 19.06 53.0
JTOR280VAEFBS1 32 27.8 16.46 35.3 20.91 56.5
JTOR300VAEFBS1 32 32.7 19.38 37.1 21.96 61.0
380 3~/N 60 418 342
JTOR320VAEFBS1 32 36.3 21.52 41.6 24.62 66.5
JTOR340VAEFBS1 43 37.1 21.98 43.7 25.86 70.5
JTOR360VAEFBS1 43 40.1 23.78 46.2 27.35 75.0
JTOR380VAEFBS1 32 47.2 27.98 49.3 29.20 82.5
JTOR400VAEFBS1 43 48.2 28.58 56.4 33.44 82.0
JTOR420VAEFBS1 43 52.8 31.26 57.1 33.84 90.5
JTOR440VAEFBS1 43 54.4 32.20 69.7 41.29 89.5
JTOR460VAEFBS1 43 59.0 34.96 66.6 39.48 98.0
JTOR480VAEFBS1 43 64.8 38.39 65.7 38.93 106.0
JTOR500VAEFBS1 55 56.4 33.41 63.8 37.80 104.0
JTOR520VAEFBS1 67 57.2 33.87 65.1 38.55 107.5
JTOR540VAEFBS1 67 60.2 35.67 66.8 39.56 112.0

VOL: Rated Unit Power Supply Voltage (Plated)(V) RNC: Running Current (A)
HZ: Frequency (Hz) IPT: Input (kW)
STC: Starting Current (A)

NOTES:
1. The above compressor data is based on 100% capacity combination of the indoor units at rated operating frequency.
2. The above performance data is based on the equivalent piping length of each unit horsepower and 0m piping lift.
3. These data are based on the same conditions as the nominal heating and cooling capacities.
4. The compressor is started by an inverter, resulting in extremely low starting current.

1-116 FAN-2209 201709


ELECTRICAL DATA

< 220V/60Hz >


Cooling Heating
Unit Main Power Applicable Voltage Maximum
Model STC Operation Operation
Current
VOL PH HZ Maximum Minimum RNC IPT RNC IPT
JTOR080VPERBS1 15 12.5 4.30 13.7 4.68 25.5
JTOR100VPERBS1 15 17.1 5.88 18.0 6.16 35.0
JTOR120VPERBS1 15 19.9 6.84 22.2 7.60 39.0
JTOR140VPERBS1 15 28.1 9.63 33.4 11.46 48.0
JTOR160VPERBS1 35 29.4 10.09 35.5 12.19 54.5
JTOR180VPERBS1 35 34.7 11.89 39.9 13.68 61.5
JTOR200VPERBS1 35 44.1 15.12 46.9 16.08 72.5
JTOR220VPERBS1 35 47.8 16.40 58.6 20.10 73.5
JTOR240VPERBS1 35 55.0 18.87 58.9 20.19 87.0
JTOR260VAERBS1 30 47.4 16.27 55.6 19.06 87.0
JTOR280VAERBS1 55 48.0 16.46 61.0 20.91 93.5
JTOR300VAERBS1 55 56.5 19.38 64.0 21.96 100.5
220 3~ 60 242 198
JTOR320VAERBS1 55 62.8 21.52 71.8 24.62 109.5
JTOR340VAERBS1 75 64.1 21.98 75.4 25.86 116.0
JTOR360VAERBS1 75 69.3 23.78 79.8 27.35 123.0
JTOR380VAERBS1 55 81.6 27.98 85.1 29.20 135.0
JTOR400VAERBS1 75 83.3 28.58 97.5 33.44 135.0
JTOR420VAERBS1 75 91.2 31.26 98.7 33.84 148.5
JTOR440VAERBS1 75 93.9 32.20 120.4 41.29 147.0
JTOR460VAERBS1 75 101.9 34.96 115.1 39.48 160.5
JTOR480VAERBS1 75 111.9 38.39 113.5 38.93 174.0
JTOR500VAERBS1 95 97.4 33.41 110.2 37.80 171.0
JTOR520VAERBS1 115 98.8 33.87 112.4 38.55 177.5
JTOR540VAERBS1 115 104.0 35.67 115.4 39.56 184.5

VOL: Rated Unit Power Supply Voltage (Plated)(V) RNC: Running Current (A)
HZ: Frequency (Hz) IPT: Input (kW)
STC: Starting Current (A)

NOTES:
1. The above compressor data is based on 100% capacity combination of the indoor units at rated operating frequency.
2. The above performance data is based on the equivalent piping length of each unit horsepower and 0m piping lift.
3. These data are based on the same conditions as the nominal heating and cooling capacities.
4. The compressor is started by an inverter, resulting in extremely low starting current.

FAN-2209 201709 1-117


SOUND DATA

8. Sound Data
8.1 Outdoor Units

Model: JTOR080VPE(U,F,R)BS1 Model: JTOR100VPE(U,F,R)BS1

Model: JTOR120VPE(U,F,R)BS1 Model: JTOR140VPE(U,F,R)BS1

NOTE:
The readings were taken in an anechoic chamber. Sound in actural status may get bigger due to surrounding noise or echo.
Take noise source into consideration to look for proper installation location.
(Noise on the back surface will go up 6 to 7dB higher than the front surface.)

1-118 FAN-2209 201709


SOUND DATA

Model: JTOR160VPE(U,F,R)BS1 Model: JTOR180VPE(U,F,R)BS1

Model: JTOR200VPE(U,F,R)BS1 Model: JTOR220VPE(U,F,R)BS1

NOTE:
The readings were taken in an anechoic chamber. Sound in actural status may get bigger due to surrounding noise or echo.
Take noise source into consideration to look for proper installation location.
(Noise on the back surface will go up 6 to 7dB higher than the front surface.)

FAN-2209 201709 1-119


SOUND DATA

Model: JTOR240VPE(U,F,R)BS1 Model: JTOR260VAE(U,F,R)BS1

Model: JTOR280VAE(U,F,R)BS1 Model: JTOR300VAE(U,F,R)BS1

NOTE:
The readings were taken in an anechoic chamber. Sound in actural status may get bigger due to surrounding noise or echo.
Take noise source into consideration to look for proper installation location.
(Noise on the back surface will go up 6 to 7dB higher than the front surface.)

1-120 FAN-2209 201709


SOUND DATA

Model: JTOR320VAE(U,F,R)BS1 Model: JTOR340VAE(U,F,R)BS1

Model: JTOR360VAE(U,F,R)BS1 Model: JTOR380VAE(U,F,R)BS1

NOTE:
The readings were taken in an anechoic chamber. Sound in actural status may get bigger due to surrounding noise or echo.
Take noise source into consideration to look for proper installation location.
(Noise on the back surface will go up 6 to 7dB higher than the front surface.)

FAN-2209 201709 1-121


SOUND DATA

Model: JTOR400VAE(U,F,R)BS1 Model: JTOR420VAE(U,F,R)BS1

Model: JTOR440VAE(U,F,R)BS1 Model: JTOR460VAE(U,F,R)BS1

NOTE:
The readings were taken in an anechoic chamber. Sound in actural status may get bigger due to surrounding noise or echo.
Take noise source into consideration to look for proper installation location.
(Noise on the back surface will go up 6 to 7dB higher than the front surface.)

1-122 FAN-2209 201709


SOUND DATA

Model: JTOR480VAE(U,F,R)BS1 Model: JTOR500VAE(U,F,R)BS1

Model: JTOR520VAE(U,F,R)BS1 Model: JTOR540VAE(U,F,R)BS1

NOTE:
The readings were taken in an anechoic chamber. Sound in actural status may get bigger due to surrounding noise or echo.
Take noise source into consideration to look for proper installation location.
(Noise on the back surface will go up 6 to 7dB higher than the front surface.)

FAN-2209 201709 1-123


SOUND DATA

8.2 CH-Box

Model: JCH-AP160SSX, JCH-AP280SSX


Measurement Point: 1 Meter from the
CH-Box Bottom Surface

NOTES:
1. The readings were taken in anechoic chamber. Sound in actual status may get bigger due to surroundings noise or echo.
Take noise source into consideration to look for proper installation location.
2. CH-Box operation sound may be heard even if the indoor unit has stopped while the outdoor units are in operation and the other
indoor units are at Thermo-ON.
3. “Operation Sound” is the CH-Box operation sound when the whole system is in either cooling or heating operation.
(Not in cooling and heating operation)
4. “Maximum Sound” is the maximum value of CH-Box operation spund while the unit is in cooling and heating operation or
defrosting.
5. The maximum sound may be exceeded during transient operation such as switching to Defrosting Mode.
Ensure the installation place.
Do not install the CH-Box in a place near bedreooms or hospital rooms.
(Refer to the Installation Manual.)

1-124 FAN-2209 201709


SOUND DATA

Model: JCH-AP04MSSX Model: JCH-AP08MSSX


Measurement Point: 1 Meter from the Measurement Point: 1 Meter from the
CH-Box Bottom Surface CH-Box Bottom Surface

Model: JCH-AP12MSSX Model: JCH-AP16MSSX


Measurement Point: 1 Meter from the Measurement Point: 1 Meter from the
CH-Box Bottom Surface CH-Box Bottom Surface

NOTES:
1. The readings were taken in anechoic chamber. Sound in actual status may get bigger due to surroundings noise or echo.
Take noise source into consideration to look for proper installation location.
2. CH-Box operation sound may be heard even if the indoor unit has stopped while the outdoor units are in operation and the other
indoor units are at Thermo-ON.
3. “Operation Sound” is the CH-Box operation sound when the whole system is in either cooling or heating operation.
(Not in cooling and heating operation)
4. “Maximum Sound” is the maximum value of CH-Box operation sound while the unit is in cooling and heating operation or
defrosting.
5. The maximum sound may be exceeded during transient operation such as switching to Defrosting Mode.
Ensure the installation place.
Do not install the CH-Box in a place near bedreooms or hospital rooms.
(Refer to the Installation Manual.)

FAN-2209 201709 1-125


CENTER OF GRAVITY

9. Center of Gravity

Net Weight (kg) Center of Gravity (mm) Outer Dimensions (mm)


Outdoor Unit X Y Z
(HP) 220V 380V 460V 380V 380V 380V A B C
220V 220V 220V
460V 460V 460V
8
190 195 200 349 343 563 575
10 556 554 950 765 1675
12 210 215 220 348 342 556 568
14 266 271 276 653 652 348 344 607 615
16 309 314 319 1210 765 1675
688 687 324 320 558 596
18 310 315 320
20 350 355 360 833 331 328 582 588
22 364 369 374 830 1600 765 1675
832 323 320 570 576
24 365 370 375

1-126 FAN-2209 201709


WORKING RANGE

10. Working Range

Power Supply
Working Voltage: 90% to 110% of the Rated Voltage
Voltage Imbalance: Within a 3% Deviation from Each Voltage at the Main Terminal of Outdoor Unit
Starting Voltage: Higher than 85% of the Rated Voltage

Temperature Range
The temperature ranges are given in the following table.

Cooling Operation
55

50
48
(*1)
45
43
40
Outdoor Air Inlet Temperature (oCDB)

35
Continuous Operation Range (*2)

Heating Operation
30 20
(at Pull-down Operation)
Operation Range

25 15
Outdoor Air Inlet Temperature (oCWB)

Continuous Operation Range (*4)


20 10

15 5

10 0

5 -5

0 -10

Additional Operation Range -5 -15


with Low Ambient Setting Operation
Range (*3)
-10 -20
15 20 23 25 10 15 20 25 27 30
Indoor Air Inlet Temperature ( CWB) o
Indoor Air Inlet Temperature (oCDB)

Heat Recovery Operation


Cooling Operation Heating Operation
Cooling Operation Heating Operation
Indoor
15 to 23oC WB 15 to 27oC DB 15 to 23oC WB 15 to 27oC DB
Air Inlet Temperature
-5 to 24oC DB
-5 to 48oC DB (*1)
-6 to 15oC WB
Outdoor
with Low Ambient Setting (*6) -20 to 15oC WB with Low Ambient Setting (*6)
Air Inlet Temperature
-10 to 48oC DB -10 to 24oC DB
-11 to 15oC WB

FAN-2209 201709 1-127


WORKING RANGE

NOTES:
*1.(1) Cooling operation at maximum 48oC DB is available only if the outdoor air inlet temperature increase
temporarily caused by installation condition.
(2) If install the units to the place where continuously exceed ambient temperature 48oC, the
combination ratio must be lower than 130% and not to operate all of the indoor unit simultaneously.
(3) The cooling capacity is deteriorated at high ambient temperature. Select the larger capacity outdoor
unit than compatible building heat load.
(4) The appropriate amount (100%) of refrigerant must be charged. Excessive charging of refrigerant is
forbidden.
(5) Avoid to install the units where affected by direct sunlight reflection and short circuit. There may
be the possibility to activate protection control and alarm system if install the units to inappropriate
place. The life time of the products and parts are considerably shortened.
(6) Periodic maintenance (1/certain month) must be applied to the heat exchanger fin to avoid adhesion
of dirt and clogging of sand to the outdoor unit heat exchanger.

*2. There might be the possibility of thermo-OFF when operate the outdoor unit under the low cooling
load condition and in the low outdoor air temperature (10oC DB or lower) to prevent indoor unit heat
exchanger from frost formation.
*3. Indoor air inlet temperature at heating operation from 15oC to 27oC WB is under assumption of limited
time operation such as at the time of startup in the early morning and not suitable for long time
continuous operation.
*4. There might be the possibility of thermo-OFF when operate the outdoor unit under the low heating
load condition and in the high outdoor air temperature (higher than 15oC DB) to prevent the outdoor
unit. The outdoor unit operation stops when outdoor air inlet temperature exceed 26oC DB.
*5. Operational range is different when connect to All Fresh Air Unit, Econofresh, and other special
indoor units.
*6. In case cooling operation or simultaneous operation under the inlet air temperature -5oC or lower the
conditions listed below must be considered at the time of installation.
• Make sure to apply Snow Protection Hood (Optional Part) .
• The minimum capacity of indoor unit connectable is 2.5HP
• Set the function “Cooling Operation Under Low Load Operation” (DSW6) from the outdoor unit
(If multiple outdoor units are connected in a system set the function only for outdoor unit A).
• Make sure to apply new CH-Box (Optional Parts).
The “Low Ambient Setting” is not available if the system is connected with current CH unit.

1-128 FAN-2209 201709


OPTIONAL ACCESSORIES

11. Optional Accessories


11.1 Piping Connection Kit
Applicable Outdoor Unit
Item Connectivity Model Remarks
Outdoor Unit HP
Number
for Low Pressure Gas: 1
26 - 48 2 MC-NP21SX for High/Low Pressure Gas: 1
Piping for Liquid: 1
Connection
Kit for Low Pressure Gas: 2
50 - 54 3 MC-NP30SX for High/Low Pressure Gas: 2
for Liquid: 2
NOTE:
The old model (MC-TTA1) is not available.

● Construction Example (In Case of 50HP: 3 Units Combination)

For Piping from Front Side Piping Cover


- Perform the piping connection between
Piping Connection Kit 1 (Liquid) outdoor units according to this figure.
High/Low Pressure Gas Piping
(Field-Supplied) - Refer to “Installation & Maintenance Manual”
Accessory Pipe Indoor Unit A of the outdoor unit for the dimension and
distance between outdoor units and between
Liquid Piping piping connection kits.
(Field-Supplied) Piping Connection Kit 2 (Liquid)

Accessory
Indoor Unit B
Pipe
Indoor Unit C

Foundation

P
Low Pressure Gas Piping
(Field-Supplied)
Accessory Pipe <View from P>
Piping Connection Kit 1 (L-Shape)
(Low Pressure Gas)
Foundation
Accessory
Low Pressure Gas Piping Pipe
Piping Connection Kit 1
(Field-Supplied)
(High/Low Pressure Gas)
Accessory Pipe
High/Low Pressure Gas Piping
(L-Shape)
(Field-Supplied)
Piping Connection Kit 2
(Low Pressure Gas)
Piping Connection Kit 2 Liquid Piping
(High/Low Pressure Gas) High/Low Pressure Gas Piping
(Field-Supplied) ˃ 500mm (Field-Supplied)

For Piping from Bottom Base


- Perform the piping connection between
outdoor units according to this figure.
Piping Connection Kit 1 Outdoor Unit A
- Refer to “Installation & Maintenance Manual”
(Liquid) Accesory Pipe of the outdoor unit for the dimension and
(Z-Shape) distance between outdoor units and between
Piping Connection Kit 2
(Liquid) piping connection kits.
Liquid Piping
(Field-Supplied)

Accesory Pipe
(Z-Shape)
High/Low Pressure Gas Piping
(Field-Supplied) Outdoor Unit B
Base
Low Pressure Gas Piping (Field-Supplied)
(Field-Supplied)

Piping Connection Kit 1


(High/Low Pressure Gas)
Accesory Pipe
Piping Connection Kit 1
(L-Shape)
(Low Pressure Gas)

Piping Connection Kit 2


(High/Low Pressure Gas) Accesory Pipe
(L-Shape)
Piping Connection Kit 2
(Low Pressure Gas)
Outdoor Unit C
High/Low Pressure
Liquid Piping Gas Piping Low Pressure Gas Piping
(Field-Supplied) (Field-Supplied) (Field-Supplied)

FAN-2209 201709 1-129


OPTIONAL ACCESSORIES

11.2 CH-Box
Suspension Bolt
Models: JCH-AP160SSX
JCH-AP280SSX (M10 x 2)

Number of
Connectable Indoor Unit
Branch H xDimension Net Weight
Model Connectable
W x D (mm) (kg) Total Capacity
Indoor Unit(*1)
JCH-AP160SSX 1 191x301x214 6.0 6.0HP or less (Max. 16kW) 1-7
JCH-AP280SSX 1 191x301x214 6.0 6.1HP - 10.0HP (Max. 28kW) 1-8
( 1)
* When multiple indoor units are connected to the same CH-Box, they are controlled with the same operation
mode.
NOTE:
When switching the refrigerant flow channel at Operation ON/OFF, Thermo-ON/OFF, Defrost Operation and
Operation Mode, refrigerant flow noise may be heard from CH-Box.
Therefore, install the unit in place such as under the roof of corridor so that the sound may not be heard in
the room.

Models: JCH-AP04MSSX
JCH-AP08MSSX
JCH-AP12MSSX
JCH-AP16MSSX
Suspension Bracket
(Four Places) (M10 x 4)

W
D

Number of
Connectable Indoor Unit Connectable
Branch H xDimension Net Weight
Model W x D (mm) (kg) Total Capacity Indoor Unit
per Branch(*2)
JCH-AP04MSSX 4 260x303x352 14.0 16.0HP or less (Max. 44.8kW) 1-6
JCH-AP08MSSX 8 260x543x352 25.0 30.0HP or less (Max. 85kW) 1-6
JCH-AP12MSSX 12 260x783x352 36.0 30.0HP or less (Max. 85kW) 1-6
JCH-AP16MSSX 16 260x1023x352 47.0 30.0HP or less (Max. 85kW) 1-6
( 2)
* The indoor units connected to the same branch of the CH-Box are controlled with the same
operation mode.
NOTE:
When switching the refrigerant flow channel at Operation ON/OFF, Thermo-ON/OFF, Defrost Operation and
Operation Mode, refrigerant flow noise may be heard from CH-Box.
Therefore, install the unit in place such as under the roof of corridor so that the sound may not be heard in
the room.
1-130 FAN-2209 201709
OPTIONAL ACCESSORIES

11.3 Multi-Kit

< Line Branch >

First Branch
Outdoor Unit HP Model Remarks
5 MW-NP142X3
6 - 10 MW-NP282X3
12 - 16 MW-NP452X3
For 3 pipes
18, 20 MW-NP562X3
22, 24 MW-NP692X3
26 - 54 MW-NP902X3

Multi-Kit after First Branch


Diameter (mm)
Total Indoor Unit HP High/Low Pressure Model Remarks
Gas Pipe Liquid Pipe
Gas Pipe
<6 f15.88 f12.7 f9.52 MW-NP142X3
6 - 8.99 f19.05 f15.88 f9.52
MW-NP282X3
9 - 11.99 f22.2 f19.05 f9.52
12 - 15.99 f25.4 f22.2 f12.7
MW-NP452X3
16 - 17.99 f28.58 f22.2 f12.7 For 3 pipes
18 - 21.99 f28.58 f22.2 f15.88 MW-NP562X3
22 - 25.99 f28.58 f25.4 f15.88 MW-NP692X3
26 - 35.99 f31.75 f28.58 f19.05
MW-NP902X3
> 36 f38.1 f31.75 f19.05
<6 f15.88 f9.52
6 - 8.99 f19.05 f9.52 MW-NP282A3
9 - 11.99 f22.2 f9.52
12 - 15.99 f25.4 f12.7
- MW-NP452A3 For 2 pipes
16 - 17.99 f28.58 f12.7
18 - 25.99 f28.58 f15.88 MW-NP692A3
26 - 35.99 f31.75 f19.05
MW-NP902A3
> 36 f38.1 f19.05

< Header Branch >


Total Indoor Unit HP No. of Header Branches Model
5 - 10 8 JMH-NP288X
5-8 4 JMH-NP224A
5 - 10 8 JMH-NP288A

FAN-2209 201709 1-131


OPTIONAL ACCESSORIES

11.4 Drain Boss


The drain boss is for the drain pipe connection in order to use outdoor unit bottom base as a drain pan.
• Model Name
Name Model
Drain Boss DBS-TP10A

• Quantity
Applicable Outdoor Unit HP Q'ty
8 - 18 1
20 - 36 2
38, 40 3
42 - 48 4
50 - 54 3

< Condensate Treatment >


Condensate is discharged during heating and defrosting operation. (Rain water is also discharged.)
Pay attention to the followings.
(1) Choose a place where well drainage is available or provide a drain ditch.
(2) Do not install the unit over the walkways. Condensation water may fall on people.
In case of installing the unit in such a place, provide the additional condensate pan.
(3) Do not use drain boss in the cold area. The condensate in the condensate pipe may be frozen and then
the condensate pipe may crack.

1-132 FAN-2209 201709


OPTIONAL ACCESSORIES

11.5 Air Inlet Grille

Left Side

Air Inlet Grille


HP
1 Rear Side 2 Right Side 3 Left Side

8 - 12 PSN-TP20BA PSN-TP20R PSN-TP20L

14 - 18 PSN-TP20BB PSN-TP20R x 2

20 - 24 PSN-TP20BC PSN-TP20R x 2
Right Side Rear Side

< Installation Appearance >


Unit: mm
• Outdoor Unit: JTOR080 ~ 120VPE(U,F,R)BS1

Screws (3 pcs.)
(Accessory)
Existing Screws
(3 pcs.) Outdoor Unit

1675
with Outdoor Unit

1 3
Air Inlet Grille Air Inlet Grille
(For Rear Side (For Left Side
Installation) Installation)
2 12.5 950 12.5 765
Air Inlet Grille
(For Right Side
Installation)
< Right Side > < Rear Side > < Left Side >

• Outdoor Unit: JTOR140 ~ 180VPE(U,F,R)BS1


3
Air Inlet Grille
Screws (10 pcs.) (For Left Side
(Accessory) Installation)

Outdoor Unit
1675

1
Air Inlet Grille
2 (For Rear Side
Air Inlet Grille Installation)
(For Right Side
Installation) 12.5 1210 12.5 765

< Right Side > < Rear Side > < Left Side >

• Outdoor Unit: JTOR200 ~ 240VPE(U,F,R)BS1


3
Air Inlet Grille
(For Left Side
Screws (24 pcs.)
Installation)
(Accessory)
Rear Attachment
Plate
1675

1
Air Inlet Grille
2 (For Rear Side
Air Inlet Grille Installation)
(For Right Side
Installation) 12.5 1600 12.5 765
Outdoor Unit

< Right Side > < Rear Side > < Left Side >

FAN-2209 201709 1-133


OPTIONAL ACCESSORIES

11.6 Protection Net

Left Side

Protection Net
HP
1 Rear Side 2 Right Side 3 Left Side

8 - 12 PN-TP20BA PN-TP20R PN-TP20L

14 - 18 PN-TP20BB PN-TP20R x 2

20 - 24 PN-TP20BC PN-TP20R x 2
Right Side Rear Side

< Installation Appearance >


Unit: mm
• Outdoor Unit: JTOR080 ~ 120VPE(U,F,R)BS1
3
Protection Net
(For Left Side Installation)

Screws (10 pcs.)


(Accessory)

1675
1
2 Protection Net
Protection Net (For Rear Side
(For Right Side Installation)
Installation)
Outdoor Unit
950 765

< Right Side > < Rear Side > < Left Side >

• Outdoor Unit: JTOR140 ~ 180VPE(U,F,R)BS1 3


Protection Net
(For Left Side Installation)

Screws (10 pcs.)


(Accessory)
1675

1
2 Protection Net
Protection Net (For Rear Side
(For Right Side Installation)
Installation) Outdoor Unit
1210 765

< Right Side > < Rear Side > < Left Side >

• Outdoor Unit: JTOR200 ~ 240VPE(U,F,R)BS1 3


Protection Net
(For Left Side Installation)
Screws (10 pcs.)
(Accessory)
Rear Attachment
Plate
1675

2 1
Protection Net
Protection Net
(For Right Side
(For Rear Side
Installation) Installation)
Outdoor Unit
1600 85 765
100 100
< Right Side > < Rear Side > < Left Side >

1-134 FAN-2209 201709


CONTROL SYSTEM

12. Control System


12.1 Refrigeration Cycle
12.1.1 Outdoor Units

Model: JTOR080VPE(U,F,R)BS1 - JTOR120VPE(U,F,R)BS1

Model: JTOR140VPE(U,F,R)BS1

FAN-2209 201709 1-135


CONTROL SYSTEM

Model: JTOR160VPE(U,F,R)BS1 and JTOR180VPE(U,F,R)BS1

Model: JTOR200VPE(U,F,R)BS1 - JTOR240VPE(U,F,R)BS1

1-136 FAN-2209 201709


CONTROL SYSTEM

12.1.2 CH-Box

Model: JCH-AP160SSX, JCH-AP280SSX

Model: JCH-AP04MSSX

FAN-2209 201709 1-137


CONTROL SYSTEM

Model: JCH-AP08MSSX

Model: JCH-AP12MSSX

1-138 FAN-2209 201709


CONTROL SYSTEM

Model: JCH-AP16MSSX

FAN-2209 201709 1-139


CONTROL SYSTEM

12.2 Control System

■ Cycle Control

Control
Heating Operation
Control Device Cooling Operation * Defrosting
Cooling and Heating Operation
Control Category Purpose of Control Control Category Purpose of Control Condition
Inverter Frequency Control Inverter Frequency Control
All of the
Inverter Frequency of Total I.U. is carried out to make I.U. Total I.U. is carried out to make I.U.
compressors:
Compressor Operating Capacity air inlet temperature to Operating Capacity air inlet temperature to
ON
temperature setpoint. temperature setpoint.

PI control is carried out to


Electronic Expansion
achieve the targeted value
Valve for O.U. Capacity Control Fully open O.U. Heat Exchanger SH Fully open
of O.U. heat exchanger
Heat Exchanger
SH.

Electronic Expansion PI Control is carried out to PI Control is carried out to


Valve for Supercooling Tsc - Tchg achieve the target value of Tchg - Tsc achieve the target value of Tsc - Tchg
Heat Exchanger Tsc - Tchg. Tchg - Tsc.

Controls supercooling
Electronic Expansion PI control is carried out to I.U. Heat
of I.U. liquid thermistor
Valve for I.U. I.U. Heat Exchanger SH achieve the targeted value I.U. Heat Exchanger SC Exchanger SH
to achieve the targeted
Heat Exchanger of I.U. heat exchanger SH. Control
value.

PI control is carried out to PI control is carried out to


Outdoor Fan Pd Control achieve the targeted value Ps Control achieve the targeted value Stop
of Pd. of Ps.

1. Pd Increase Protection 1. Pd>3.6MPa 1. Pd Increase Protection 1. Pd>3.5MPa


Gas Bypass Valve (522psi): Open (508psi): Open
Closed
(SVA) 2. Ps Decrease Protection 2. Ps<0.20MPa 2. Ps Decrease Protection 2. Ps<0.1MPa
(29psi): Open (14psi): Open

(*): Dry operation is included in the cooling operation.

Pd: Discharge Pressure


Ps: Suction Pressure
SH Superheat
Tsc: Subcooler Temperature
Tchg: Liquid Stop Valve Temperature
I.U.: Indoor Unit
O.U.: Outdoor Unit

1-140 FAN-2209 201709


CONTROL SYSTEM

■ Compressor Operation Control

(1) Compressor Rotation Control


This compressor rotation control is performed in order to make the compressor operating time equal
for each outdoor unit.
This control is performed during the outdoor unit thermo-OFF or switch OFF.
When turning ON the outdoor unit, the inverter compressor with the shortest operating time (average
operating time for the outdoor unit installed two inverter compressors) will operate preferentially.
At least 2 outdoor units are required for this function.

The operating sequence of compressor rotation control is as follows.

JTOR260VAE(U,F,R)BS1

Outdoor Unit A Outdoor Unit B < Compressor Operating Sequence >


Outdoor Unit A Outdoor Unit B
Inverter Compressor
Last Time 1 2
This Time 2 1
Next Time 1 2

Inverter Compressor

JTOR280 - 320, 380VAE(U,F,R)BS1

Outdoor Unit A Outdoor Unit B < Compressor Operating Sequence >


Outdoor Unit A Outdoor Unit B
Inverter Inverter Inverter
Compressor 1 Compressor 2 Compressor
Last Time 1 3 2
This Time 2 3 1
Next Time 1 3 2

NOTE:
Inverter Compressor 1 Inverter Compressor
When turning ON the outdoor unit A, the inverter compressor 1
Inverter / Constant Compressor 2 or 2 with the shortest operating time will operate preferentially.

JTOR340, 360, 400 - 480VAE(U,F,R)BS1

< Compressor Operating Sequence >


Outdoor Unit A Outdoor Unit B
Outdoor Unit A Outdoor Unit B
Inverter Inverter Inverter Inverter
Compressor 1 Compressor 2 Compressor 1 Compressor 2
Last Time 1 3 2 3
This Time 2 3 1 3
Next Time 1 3 2 3

NOTE:
Inverter Compressor 1 Inverter Compressor 1 When turning ON the outdoor units, the inverter compressor of each
Constant Compressor 2 Constant Compressor 2 outdoor unit with the shortest operating time will operate preferentially.

FAN-2209 201709 1-141


CONTROL SYSTEM

JTOR500VAE(U,F,R)BS1

Outdoor Unit A Outdoor Unit B Outdoor Unit C

Inverter Compressor 1 Inverter Compressor 1 Inverter Compressor


Inverter Compressor 2 Inverter Compressor 2

< Compressor Operating Sequence >


Outdoor Unit A Outdoor Unit B Outdoor Unit C
Inverter Compressor 1 Inverter Compressor 2 Inverter Compressor 1 Inverter Compressor 2 Inverter Compressor
Last Time 1 4 2 4 3
This Time 2 4 1 4 2
Next Time 2 4 3 4 1

NOTE:
When turning ON the outdoor units, the inverter compressor of the outdoor unit A and B with the shortest operating time will
operate preferentially.

JTOR520, 540VAE(U,F,R)BS1

Outdoor Unit A Outdoor Unit B Outdoor Unit C

Inverter Compressor 1 Inverter Compressor 1 Inverter Compressor 1


Inverter Compressor 2 Inverter Compressor 2 Inverter Compressor 2

< Compressor Operating Sequence >


Outdoor Unit A Outdoor Unit B Outdoor Unit C
Inverter Inverter Inverter Inverter Inverter Inverter
Compressor 1 Compressor 2 Compressor 1 Compressor 2 Compressor 1 Compressor 2
Last Time 1 4 2 4 3 4
This Time 3 4 1 4 2 4
Next Time 2 4 3 4 1 4

NOTE:
When turning ON the outdoor units, the inverter compressor of each outdoor unit with the shortest operating
time will operate preferentially.

1-142 FAN-2209 201709


CONTROL SYSTEM

(2) Compressor Frequency Control


Compressor Operation Control is to adjust the output frequency of an Inverter Compressor according
to Target Frequency.
(Target Frequency is determined by capacity control according to cooling and heating loads.)
Therefore, when the load is smaller, all compressors may not operate.

■ In case of single outdoor unit with two inverter compressors installed

JTOR160 - 200VPE(U,F,R)BS1

(A) 2 (Two) Inverter Compressors


Compressor 1 (One)
Operation Inverter
Status Compressor

Each Compressor Frequency [Hz]


Target Increase Direction Decrease Direction
Frequency Comp. Comp.
 [Hz] No.1 No.2 No.1 No.2
Operation Operation
Comp. Comp. Comp. Comp.
Status Status
11.0 1 11.0 ― 1 11.0 ―

Frequency of 41.0 1 41.0 ― 1 41.0 ―


Inverter Comp. 42.0 1 42.0 ― 2 21.0 21.0
(Hz) 80.0 1 80.0 ― 2 40.0 40.0
81.0 2 40.5 40.5 2 40.5 40.5
• • • • • • •
• • • • • • •
• • • • • • •


NOTE:
 Refer to page 1-146 for the maximum frequency.

  * Max.
Frequency
Target Frequency (Hz)

JTOR220, 240VPE(U,F,R)BS1

(B)
2 (Two) Inverter Compressors
Compressor
Operation 1 (One) Inverter
Status Compressor

Each Compressor Frequency [Hz]


Target Increase Direction Decrease Direction
Frequency Comp. Comp.
 [Hz] No.1 No.2 No.1 No.2
Operation Operation
Comp. Comp. Comp. Comp.
Status Status
11.0 1 11.0 ― 1 11.0 ―
Frequency of 61.0 1 61.0 ― 1 61.0 ―
Inverter Comp.
62.0 1 62.0 ― 2 31.0 31.0
(Hz)
80.0 1 80.0 ― 2 40.0 40.0
81.0 2 40.5 40.5 2 40.5 40.5
• • • • • • •
• • • • • • •

• • • • • • •

NOTE:
 Refer to page 1-146 for the maximum frequency.

  * Max.
Frequency
Target Frequency (Hz)

FAN-2209 201709 1-143


CONTROL SYSTEM

■ In case of multiple outdoor units

JTOR260 - 480VAE(U,F,R)BS1

(C)
Outdoor Unit 2 (Two) Outdoor Units
Operation 1 (One)
Status Outdoor Unit

* Max.
Frequency



Frequency of
Inverter Comp.
(Hz)





 
Target Frequency (Hz)

Each Compressor Frequency [Hz]


Target Increase Direction Decrease Direction
Frequency Comp. Comp.
[Hz] Outdoor Outdoor Outdoor Outdoor
Operation Operation
Unit (A) Unit (B) Unit (A) Unit (B)
Status Status
11.0 1 11.0 ― 1 11.0 ―
61.0 1 61.0 ― 1 61.0 ―
62.0 1 62.0 ― 2 31.0 31.0
80.0 1 80.0 ― 2 40.0 40.0
81.0 2 40.5 40.5 2 40.5 40.5
• • • • • • •
• • • • • • •
• • • • • • •

NOTE:
Refer to page 1-146 for the maximum frequency.

1-144 FAN-2209 201709


CONTROL SYSTEM

JTOR500 - 540VAE(U,F,R)BS1

3 (Three) Outdoor Unit


(D) 2 (Two)
Outdoor Unit Outdoor Units
Operation 1 (One)
Status Outdoor Unit

* Max.
Frequency





Frequency of
Inverter Comp.
(Hz)





   
Target Frequency (Hz)

Each Compressor Frequency [Hz]


Target Increase Direction Decrease Direction
Frequency Comp. Comp.
[Hz] Outdoor Outdoor Outdoor Outdoor Outdoor Outdoor
Operation Operation
Unit (A) Unit (B) Unit (C) Unit (A) Unit (B) Unit (C)
Status Status
11.0 1 11.0 ― ― 1 11.0 ― ―
61.0 1 61.0 ― ― 1 61.0 ― ―
62.0 1 62.0 ― ― 2 31.0 31.0 ―
80.0 1 80.0 ― ― 2 40.0 40.0 ―
81.0 2 40.5 40.5 ― 2 40.5 40.5 ―
92.0 2 46.0 46.0 ― 2 46.0 46.0 ―
93.0 2 46.5 46.5 ― 3 31.0 31.0 31.0
130.0 2 65.0 65.0 ― 3 43.3 43.3 43.3
131.0 3 43.6 43.6 43.6 3 43.6 43.6 43.6
• • • • • • • • •
• • • • • • • • •
• • • • • • • • •

NOTE:
Refer to page 1-146 for the maximum frequency.

FAN-2209 201709 1-145


CONTROL SYSTEM

Combination of Base Units and Maximum Frequency

Combination of Maximum
Model
Base Units Frequency [Hz]
JTOR080VPE(U,F,R)BS1 — 75
JTOR100VPE(U,F,R)BS1 — 90
JTOR120VPE(U,F,R)BS1 — 110
JTOR140VPE(U,F,R)BS1 — 130
JTOR160VPE(U,F,R)BS1 — 175
JTOR180VPE(U,F,R)BS1 — 200
JTOR200VPE(U,F,R)BS1 — 200
JTOR220VPE(U,F,R)BS1 — 250
JTOR240VPE(U,F,R)BS1 — 260
14 130
JTOR260VAE(U,F,R)BS1
12 110
16 175
JTOR280VAE(U,F,R)BS1
12 110
18 200
JTOR300VAE(U,F,R)BS1
12 110
18 200
JTOR320VAE(U,F,R)BS1
14 130
18 200
JTOR340VAE(U,F,R)BS1
16 175
18 200
JTOR360VAE(U,F,R)BS1
18 200
24 260
JTOR380VAE(U,F,R)BS1
14 130
22 250
JTOR400VAE(U,F,R)BS1
18 200
24 260
JTOR420VAE(U,F,R)BS1
18 200
22 250
JTOR440VAE(U,F,R)BS1
22 250
24 260
JTOR460VAE(U,F,R)BS1
22 250
24 260
JTOR480VAE(U,F,R)BS1
24 260
18 200
JTOR500VAE(U,F,R)BS1 18 200
14 130
18 200
JTOR520VAE(U,F,R)BS1 18 200
16 175
18 200
JTOR540VAE(U,F,R)BS1 18 200
18 200

NOTE:
The frequency in the table above indicates the total frequency of a outdoor unit if the unit is installed two
compressors.

1-146 FAN-2209 201709


CONTROL SYSTEM

(3) Compressor Capacity Control


The operating speed of the compressor is determined according to the temperature difference (∆T)
between setting temperature and indoor unit air inlet temperature detected by each indoor unit under
cooling/heating thermo-ON operation and the variation of ∆T to control compressor frequency.

The frequency is calculated as follows:


Current Frequency × Coefficient Based on the Temperature

(for Cooling Operation)


The coefficient becomes larger when the value of ∆T (the temperature difference between setting
temperature and air inlet temperature is large) or variation of ∆T is larger.
The coefficient becomes smaller when the value of ∆T (the temperature difference between setting
temperature and air inlet temperature is small) or variation of ∆T is smaller.

(for Heating Operation)


The coefficient becomes larger when the value of ∆T (the temperature difference between setting
temperature and air inlet temperature is large) or variation of ∆T is larger.
The coefficient becomes smaller when the value of ∆T (the temperature difference between setting
temperature and air inlet temperature is small) or variation of ∆T is smaller.

NOTE:
The temperature of the thermistor in the wired controller is utilized instead of indoor unit air inlet
temperature when the thermistor in the wired controller is set by functional setting mode.

FAN-2209 201709 1-147


CONTROL SYSTEM

■ Heat Exchanger Mode Control


In accordance with the connectable indoor unit operation mode, the outdoor unit heat exchanger will be
switched as shown in the table below.

O.U. Heat Exchanger Mode at Cooling: Condenser COND


O.U. Heat Exchanger Mode at Heating: Evaporator EVAP

(1) The Number of Outdoor Unit: 1 (one)

Cooling Mode Mainly Cooling Mode Mainly Heating Mode Heating Mode Defrosting Mode
Heat Exchanger Mode
COND D1 D1-1 D4 EVAP DEF1

Heat Exchanger Condition COND COND cond EVAP EVAP COND

RVR2 OFF OFF OFF ON ON OFF


Reversing Valve
RVR1 ON OFF OFF OFF OFF ON
MV1 Fully Open Pd Pd Heat Exchanger SH Heat Exchanger SH Fully Open
Expansion Valve
MVB Tsc - Tchg Tsc - Tchg Closed Tchg - Tsc Tchg - Tsc Tsc - Tchg

(2) The Number of Outdoor Unit: 2 (two)

Cooling Mode Mainly Cooling Mode Mainly Heating Mode Heating Mode
Heat Exchanger Mode
COND D1 D2 D3 D4 EVAP

Heat Exchanger Condition COND COND COND cond EVAP EVAP


Main Outdoor Unit

RVR2 OFF OFF OFF OFF ON ON


Reversing Valve
RVR1 ON OFF OFF OFF OFF OFF
MV1 Pd Pd Pd Pd Heat Exchanger SH Heat Exchanger SH
Expansion Valve
MVB Tsc - Tchg Tsc - Tchg Tsc - Tchg Closed Tchg - Tsc Tchg - Tsc

Heat Exchanger Condition COND COND evap EVAP EVAP EVAP


Sub Outdoor Unit

RVR2 OFF OFF ON ON ON ON


Reversing Valve
RVR1 ON OFF OFF OFF OFF OFF
MV1 Pd Pd Closed Heat Exchanger SH Heat Exchanger SH Heat Exchanger SH
Expansion Valve
MVB Tsc - Tchg Tsc - Tchg Closed Tchg - Tsc Tchg - Tsc Tchg - Tsc

Defrosting Mode
Heat Exchanger Mode
DEF2 DEF1
with CH-Box without CH-Box

Heat Exchanger Condition COND / EVAP COND


Main Outdoor Unit

RVR2 ON / OFF OFF


Reversing Valve
RVR1 OFF ON
MV1 Fully Open / Heat Exchanger SH Fully Open
Expansion Valve
MVB Tsc - Tchg / Tchg - Tsc Tsc - Tchg

Heat Exchanger Condition COND / EVAP COND


Sub Outdoor Unit

RVR2 ON / OFF OFF


Reversing Valve
RVR1 OFF ON
MV1 Fully Open / Heat Exchanger SH Fully Open
Expansion Valve
MVB Tsc - Tchg / Tchg - Tsc Tsc - Tchg

1-148 FAN-2209 201709


CONTROL SYSTEM

(3) The Number of Outdoor Unit: 3 (three)

Cooling Mode Mainly Cooling Mode


Heat Exchanger Mode
COND D1 D2-1 D2-2

Heat Exchanger Condition COND COND COND COND


Main Outdoor Unit

RVR2 OFF OFF OFF OFF


Reversing Valve
RVR1 ON OFF OFF OFF
MV1 Pd Pd Pd Pd
Expansion Valve
MVB Tsc - Tchg Tsc - Tchg Tsc - Tchg Tsc - Tchg

Heat Exchanger Condition


Sub Outdoor Unit 1

COND COND evap evap

RVR2 OFF OFF ON ON


Reversing Valve
RVR1 ON OFF OFF OFF
MV1 Pd Pd Closed Closed
Expansion Valve
MVB Tsc - Tchg Tsc - Tchg Closed Closed

Heat Exchanger Condition


Sub Outdoor Unit 2

COND COND COND evap

RVR2 OFF OFF OFF OFF


Reversing Valve
RVR1 ON OFF OFF OFF
MV1 Pd Pd Pd Closed
Expansion Valve
MVB Tsc - Tchg Tsc - Tchg Tsc - Tchg Closed

Mainly Heating Mode Heating Mode


Heat Exchanger Mode
D2-3 D3-1 D3-2 D4 EVAP

Heat Exchanger Condition cond cond cond EVAP EVAP


Main Outdoor Unit

RVR2 OFF OFF OFF ON ON


Reversing Valve
RVR1 OFF OFF OFF OFF OFF
MV1 Pd Pd Pd Heat Exchanger SH Heat Exchanger SH
Expansion Valve
MVB Tchg - Tsc Tchg - Tsc Tchg - Tsc Tchg - Tsc Tchg - Tsc

Heat Exchanger Condition


Sub Outdoor Unit 1

EVAP EVAP EVAP EVAP EVAP

RVR2 ON ON ON ON ON
Reversing Valve
RVR1 OFF OFF OFF OFF OFF
MV1 Heat Exchanger SH Heat Exchanger SH Heat Exchanger SH Heat Exchanger SH Heat Exchanger SH
Expansion Valve
MVB Tchg - Tsc Tchg - Tsc Tchg - Tsc Tchg - Tsc Tchg - Tsc

Heat Exchanger Condition evap EVAP EVAP EVAP


Sub Outdoor Unit 2

EVAP

RVR2 ON ON ON ON ON
Reversing Valve
RVR1 OFF OFF OFF OFF OFF
MV1 Closed Heat Exchanger SH Heat Exchanger SH Heat Exchanger SH Heat Exchanger SH
Expansion Valve
MVB Closed Tchg - Tsc Tchg - Tsc Tchg - Tsc Tchg - Tsc

FAN-2209 201709 1-149


CONTROL SYSTEM

Defrosting Mode
Heat Exchanger Mode
DEF2 DEF1
with CH-Box without CH-Box

Heat Exchanger Condition COND / EVAP COND


Main Outdoor Unit

RVR2 OFF / ON OFF


Reversing Valve
RVR1 OFF ON
MV1 Fully Open / Heat Exchanger SH Fully Open
Expansion Valve
MVB Tsc - Tchg / Tchg - Tsc Tsc - Tchg

Heat Exchanger Condition COND / EVAP COND


Sub Outdoor Unit 1

RVR2 OFF / ON OFF


Reversing Valve
RVR1 OFF ON
MV1 Fully Open / Heat Exchanger SH Fully Open
Expansion Valve
MVB Tsc - Tchg / Tchg - Tsc Tsc - Tchg

Heat Exchanger Condition COND / EVAP COND


Sub Outdoor Unit 2

RVR2 OFF / ON OFF


Reversing Valve
RVR1 OFF ON
MV1 Fully Open / Heat Exchanger SH Fully Open
Expansion Valve
MVB Tsc - Tchg / Tchg - Tsc Tsc - Tchg

NOTES:
1. Condition of Heat Exchanger
COND : Use as Condenser
EVAP : Use as Evaporator
cond : Avoid the use of Heat Exchanger (under the high pressure condition)
evap : Avoid the use of Heat Ec\xchanger (under the low pressure condition)

2. Control Method of Expansion Valve


Pd - Normally fully open. (The opening is depending on the refrigerant cycle condition.)
PI control is performed to achieve the targeted value of discharge pressure when discharge pressure
decreases.
Tsc - Tchg and Tchg - Tsc: PI control is carried out to achieve the target value of temperature difference between
Tsc and Tchg.
Heat Exchanger SH: PI control is carried out to achieve the targeted value of outdoor heat exchanger SH.

1-150 FAN-2209 201709


CONTROL SYSTEM

The figure below is a representation of the control system.

Example: Combination of Base Units, JTOR080 - 120VPE(U,F,R)BS1 + Indoor Unit

to Transmission Circuit of
Thermistor for Inlet Air
Combination Outdoor Unit Multiple Signals
Thermistor of Outlet Air
Thermistor for Ambient Temperature “TA” (THM7) Single Signal
Thermistor for Gas Pipe
Thermistor for Liquid Pipe Discharge Gas Thermistor “TD1” (THM8) Operation Signal
Thermistor for Evaporation Liquid Line Temperature “TE” (THM10)
Wireless Remote
Control Switch Thermistor for Evaporation Gas Line Temperature “TG” (THM12)
Communication

Thermistor for Liquid Stop Valve Temperature “TCHG” (THM17)


Remote Thermistor for Subcooler Temperature “TSC” (THM23)
Control Discharge Gas Pressure Sensor (Pd)
Circuit

MOCK Suction Gas Pressure Sensor (PS)

Protection
Wireless Communication Circuit
Circuit A D A D
Communication Conversion
Circuit Circuit
Remote Control Switch
Communication

Inverter Power
Communication

Communication

Inverter Section for MC


Remote Indoor Unit Outdoor Unit
MCU Control
Control MCU
Circuit

MCU
Circuit

Circuit

MCU

Electrical Control Relay Fan Electrical Control Relay Inverter Power


Protection Expansion Valve Drive Section for
Expansion Valve Drive Control
Circuit Drive Circuit Circuit MOF MC1
Drive Circuit Circuit Circuit

MD MS MVB MV CH RVR RVR SVA


MV MIF 1 1 1 2
SVG MOF

To Communication Circuit of the next Indoor Unit


or the next Outdoor Unit (H-LINK II)

Indoor Unit Outdoor Unit

Symbol Name
THM Thermistor
MCU Microcontroller
MC1 DC Motor (for Inverter Compressor)
MOF DC Motor (for Outdoor Fan)
MIF Motor (for Indoor Fan)
MS Motor (for Auto-Louver)
MD Motor (for Drain Pump)
MV Electronic Expansion Valve (for Indoor Unit)
MV1 Electronic Expansion Valve (for Outdoor Unit)
MVB Electronic Expansion Valve for Supercooling Heat Exchanger
SVA Solenoid Valve
SVG Solenoid Valve
RVR1 Reversing Valve
RVR2 Reversing Valve
CH1 Crankcase Heater

FAN-2209 201709 1-151


CONTROL SYSTEM

12.3 Standard Operation Sequence

■ Cooling Operation
I.U.: Indoor Unit
O.U.: Outdoor Unit

Auto - louver only for Indoor Unit


0 Reset with Auto-Louver Start of Transmitting between
Power to Power to I.U. and O.U.
I.U.: ON I.U. PCB: ON Start of Transmitting between
OFF I.U. and Remote Control Switch
(Higher than
Activation Level)
Float Switch MD Operation: ON

for Unit with Drain Pump


ON
(Lower than
Activation Level)
Set
Operation Mode COOL Indication
at “COOL”.

High HIGH Indication

Press Air Flow Medium MEDIUM


FAN Switch Change Over
Indication
Switch

Low
LOW Indication

Press Switch: Increasing Set Temp.


Indication of Set Temp.
Temp. Switch Switch: Decreasing Set Temp.

RUN indicator lights.


Press
RUN/STOP
Switch
MIF Operation at Set Fan Speed

Higher than
Set Temp.
(Thermo-ON) > -5oC
Cooling I.U.
Outdoor PID Control for I.U.
Operation Air Intake
Temp. Electronic Expansion Valve
Temp.
Lower than < -5oC
Set Temp.
(Thermo-OFF)

Thermo-OFF

No
3 min.

Yes

to 1

1-152 FAN-2209 201709


CONTROL SYSTEM

■ Cooling Operation

1
I.U.: Indoor Unit

Start of
Auto-Louver
Press only for Air Panel
AUTO-LOUVER < Alternately > or Indoor Unit
Switch with Auto-Louver
Stop of
Auto-Louver

Press
RUN/STOP
Switch No
Yes
After 3 min. MD : Operation: OFF
20 sec.
for Unit with Drain Pump

MIF Operation : OFF

RUN indicator: OFF, COOL, Set Fan Speed


STOP & Set Temp. Indications: Continuously ON

Electronic Expansion Valve in I.U.:


Fixed Opening

Power to Power to I.U. PCB: OFF


I.U.: OFF LCD Indication: OFF

FAN-2209 201709 1-153


CONTROL SYSTEM

■ Dry Operation

I.U.: Indoor Unit


O.U.: Outdoor Unit

Auto - louver only for Indoor Unit


0 Reset with Auto-Louver
Start of Transmitting between
Power to I.U. and O.U.
Power to I.U. PCB: ON Start of Transmitting between
I.U.: ON I.U. and Remote Control Switch
OFF
(Higher than Activation Level)
Float Switch
MD Operation: ON
ON
for Unit with Drain Pump
(Lower than Activation Level)

Set
Operation Mode DRY Indication
at “DRY”.

Press Switch: Increasing Set Temp.


TEMP. Switch Indication of Set Temp.
Switch: Decreasing Set Temp.

Press
RUN/STOP RUN indicator lights.
Switch

Higher than
Set Temp.
(Thermo-ON)
I.U. Air > -5oC
DRY Operation Intake MIF Operation at Low Fan Speed Outdoor PID Control for I.U.
Temp. Temp. Electric Expansion Valve
< -5oC

Lower than
Set Temp.
(Thermo-OFF)
MIF Operation at SLo Fan Speed

No
3 min.

Yes

MIF Operation at Low Fan Speed

to 2

1-154 FAN-2209 201709


CONTROL SYSTEM

■ Dry Operation

2
I.U.: Indoor Unit

Start of
Auto-Louver
Press only for Air Panel
AUTO-LOUVER < Alternately > or Indoor Unit
Switch with Auto-Louver
Stop of
Auto-Louver

Press
RUN/STOP
Switch No

After 3 min.
MD Operation: OFF
20 sec.
Yes
for Unit with Drain Pump

MIF Operation: OFF

RUN Indicator: OFF, COOL, Set Fan Speed


STOP & Set Temp. Indications: Continuously ON

Electronic Expansion Valve in I.U.:


Fixed Opening

Power to
Power to I.U. PCB: OFF LCD Indication: OFF
I.U.: OFF

FAN-2209 201709 1-155


CONTROL SYSTEM

■ Freezing Protection Control during Cooling or Dry Operation

Power Supply

Cooling Operation or
Dry Operation

Is compressor operated
No for more than *15 min. or
the accumulated operation time of
compressor exceeded
30 min.?
* The judging time varies depending on indoor unit model.
Yes

Cooling Operation or
Dry Operation

Pipe Surface Temp. of > 0oC


Indoor Heat Exchanger
or Gas Pipe Surface
Temp.

< 0 oC

Is it continuous for No
more than 3 min.?

Yes

MIF Operation at Set Fan Speed (In Case


of DRY Operation MIF OFF for 6 min.)

I.U. Electronic Expansion Valve:


Completely Closed

Is it continuous
for more than 3 min.? No
(6 min. in case of DRY
Operation)

Yes

No

Pipe Surface Temp. of < 15oC Yes


Indoor Heat Exchanger After 15 min.
or Gas Pipe Surface
Temp.
> 15oC

Liquid Pipe Temp. of < 3oC


Indoor Heat Exchanger

> 3o C

1-156 FAN-2209 201709


CONTROL SYSTEM

■ Heating Operation

I.U.: Indoor Unit


O.U.: Outdoor Unit

Start of Transmitting between


Power to Power to I.U. and O.U.
I.U.: ON I.U. PCB: ON Start of Transmitting between
I.U. and Remote Control Switch
Auto - louver only for Indoor Unit
0 Reset with Auto-Louver

Set
Operation Mode HEAT Indication
at "HEAT".

High HIGH Indication

Air Flow Medium


Set MEDIUM Indication
Changeover
Fan Speed
Switch

Low LOW Indication

Press Switch: Increasing Set Temp.


Temp. Switch Indication of Set Temp.
Switch: Decreasing Set Temp.

Press
RUN/STOP RUN indicator lights.
Switch

Lower than
Setting Temp.
Heating (Thermo-ON) PID Control for I.U.
I.U. Intake
Operation Air Temp. and O.U. Electronic
Expansion Valve
Higher than
Setting Temp.
(Thermo-OFF)

MIF Operation at Cut the power to Y52H


Heating Load
SLo Fan Speed

Operate H1 auxiliary
Power to Y52H Power to 52H
electrical heater
Indoor Fan Stop
Y52H: Relay for auxiliary electrical heater
52H: Electromagnetic contactor for auxiliary electrical heater

Yes
Pd < 2.2MPa

No After 3 to 48 sec.

MIF Operation at
< 25oC > 30oC
Set Fan Speed
MIF Operation at I.U. Air
SLo Fan Speed Outlet Temp.
Permitting Downward
Air Flow by Auto-Louver
MIF Operation at 25 to less than 30oC only for Indoor Unit
Lo Fan Speed with Auto-Louver

To 3

FAN-2209 201709 1-157


CONTROL SYSTEM

■ Heating Operation

3
I.U.: Indoor Unit
O.U. Outdoor Unit
Start of
Auto-Louver
Press only for Air Panel
Auto-Louver < Alternately > or Indoor Unit
Switch with Auto-Louver
Stop of
Auto-Louver

Y52H: Relay for auxiliary electrical heater


52H: Electromagnetic contactor for auxiliary electrical heater

Cut the power to Y52H Cut the power to 52H Auxiliary electrical heater H1 : OFF
Press
RUN/STOP
Switch
I.U. Air < 50oC
Indoor Fan Motor MIF : OFF
Outlet Temp.

Heat > 50oC


Rejection
< 2 min.
Operation

I.U. Air > 40°C Operation at


MIF Operation at SLo Fan Speed SLo Fan Speed
Outlet Temp.

< 40°C after 2 min.

RUN Indicator: OFF. HEAT, Set Air Flow &


Set Temp. Indications: Continuously ON

Electronic Expansion Valve in I.U. and O.U.:


Fixed Opening

STOP

Power to Power to I.U. PCB: OFF LCD Indication: OFF


I.U.: OFF

1-158 FAN-2209 201709


CONTROL SYSTEM

■ Defrosting Operation

Heating Operation

Outdoor evaporating temperature is


Yes Outdoor evaporating temperature No lower than defrosting initiation temperature
Heating Operation Time No
is lower than defrosting initiation condition (b) and outdoor fan electrical
40 minutes or Above
temperature condition (a). power increase more than 10%.
No
Yes Yes

Defrosting Operation 1

RVR2 : OFF

Outdoor FAN MOF : OFF

Compressor Operating 1 Minute Later High Frequency


at Low Frequency Operation

Fixed Opening
Degree of Electronic
Expansion Valve

PID Control for


Super Cooling Electronic
Expansion Valve

Evaporating Temperature Discharge Gas Pressure


Pd > 3.3MPa
No (Te) at Heat Exchanger is No No is 3.1MPa or Above No
Defrosting Time is and
15°C or Above and
9 minutes or Above Defrosting Time is
and Defrosting Time is
less than 20 seconds
Pd > 1.3MPa 20 seconds or Above
Yes
Yes Yes Yes

Defrosting
Completion
1: Defrosting operation signal is
transmitted to the indoor unit during
RVR2 : ON
the defrosting operation. After the
signal is received, “DEFROST” will be
indicated on LCD of remote control
Heating Operation
switch and the indoor fan will stop.

Accumulated Heating Operation Hour Temperature Condition under


Resetting Condition Defrosting Operation
To prevent initiation of defrosting operation within Outdoor Evaporating Temperature (°C)
minimum time when start operation after long time (Pipe)
10
stoppage, reset the accumulated heating operation
hour according to outdoor temperature (Ta) and Defrosting Initiation Temp. (a)
Defrosting Initiation Temp. (b)
compressor down time when turning ON the power. 5

-15 -10 -5 5 10 15 Outdoor


Compressor Down Time (min)

1000 0 7
900 Temperature
Reset the accumulated -2 (°C)
800 operation hour
-5
700 -6
600
500 -10
400
300 -15 Defrosting Operation Area
200
-18
100 -20
0
-20 -10 0 10 20
-24
Outdoor Temperature (°C) -25

FAN-2209 201709 1-159


CONTROL SYSTEM

■ Prevention Control for Excessively High Discharge Air Temperature

Heating Operation

< 65oC I.U. Air


Outlet Temp.

> 65oC

Thermo-OFF

No Is it continuous
more than 3 min.?

Yes

> 60oC I.U. Air


Outlet Temp.

< 60oC

No Is setting temp.
lower than inlet air temp.
of Indoor Unit?

Yes

Thermo-ON

Thermo ON/OFF Control of Indoor Unit

1-160 FAN-2209 201709


CONTROL SYSTEM

■ Protection Control

• Whenever protection control sequences are activated, the corresponding code is displayed on the
7-segment LED array of the main control board.
• Protection control code is displayed when a unit protection mode has been initiated. The code will
disappear once the cause of protection has been addressed.

Indicated Contents
Indication Protection Control Contents Code During Degeneration Control
P01 Pressure Ratio Protection Control Pc1
P02 High Pressure Increase Protection Control Pc2
P03 Inverter Current Protection Control Pc3
P04 Inverter Fin Temperature Increase Protection Control Pc4
P05 Discharge Temperature Increase Protection Control Pc5
P06 Low Pressure Decrease Protection Control
P09 High Pressure Decrease Protection Control

P0A Demand Current Control
P0d Low Pressure Increase Protection Control

(1) P01: Pressure Ratio Protection Control


(a) Pressure Ratio Increase Protection Control
Pressure Ratio Increase Protection Control is performed in order to protect the compressor from an
increase of pressure ratio.

˂Details of Control˃
NOTE:
Normal Operation
1. With a combination of base units, the control in the
Pressure Ratio e ≥ 8.5 figure is performed for the entire number of outdoor
units to be connected.
Frequency Forced Decrease 2. The pressure ratio is calculated in each outdoor unit,
(1.0Hz/sec.) and this control uses the maximum value.
Pressure Ratio e < 8.2 Pressure Ratio e= (Pd [MPa]+0.1) / (Ps [MPa]+0.06)
e ≥ 8.5 e= (Pd [psi]+15) / (Ps [psi]+9)
Pd: Detected Value of High Pressure Sensor [MPa (psi)]
Prohibition of Frequency Increase
Ps: Detected Value of Low Pressure Sensor [MPa (psi)]
(Only Frequency Decrease Permitted)

Pressure Ratio e < 7.5

(b) Low Compression Ratio Protection Function


This function is activated to protect the compressor during occurrences of low compression ratio.

˂Details of Control˃

Normal Operation
Pressure Ratio e < 1.5
for 1 min.
Pressure Ratio e < 1.5 for 1 min. Abnormal Stoppage
Frequency Forced Increase
(Cause Code of I.U. Stoppage: d1 -11)
(0.25Hz/sec.)
Pressure Ratio e ≥ 1.6
Pressure Ratio
e ≤ 1.5
Prohibition of Frequency Decrease
(Only Frequency Increase Permitted) NOTE:
1. With a combination of base units, the control in the figure
is performed for the entire number of outdoor units to be
Pressure Ratio e ≥ 1.7 connected.
2. The pressure ratio is calculated in each outdoor unit, and
this control uses the minimum value.

FAN-2209 201709 1-161


CONTROL SYSTEM

(2) P02: High Pressure Increase Protection Control


High Pressure Protection Control is performed in order to prevent activation of a protection device
caused by a high pressure increase during an abnormality and to protect the compressor from an
excessive increase of discharge pressure.

˂Details of Control˃

Normal Operation
Pd ≥ P1

Frequency Forced Decrease


(1.5Hz/sec.)
Pd < P2
Pd > 3.80MPa (551psi ) for 2 sec.
Pd ≥ P1
Prohibition of Frequency Increase
(Only Frequency Decrease Permitted)
Abnormal Stoppage
(Cause Code of I.U. Stoppage: d1-13)
Pd < P3

Control Value [MPa(psi)] NOTE:


Operation Mode P1 P2 P3 1. With a combination of base units, the control in the figure
3.45 3.40 3.20 is performed for the entire number of outdoor units to be
Cooling connected.
(500) (493) (464)
3.35 3.30 3.10 2. High pressure is detected in each outdoor unit, and this
Heating control uses the maximum value.
(486) (479) (450)
Pd: Detected Value of High Pressure Sensor [MPa(pis)]

(3) P03: Inverter Current Protection Control


Inverter Current Protection Control is performed in order to prevent an inverter trip caused by an
increase of inverter secondary current value.

(a) Inverter Secondary Current Protection

˂Details of Control˃

Normal Operation Control Value


Iinv ≥ I1 (A) ˂220V˃
Outdoor Unit Model [HP] I1 I2 I3 I4 I5
8, 10, 16 to 20 35.5 36.5 37.0 38.0 38.0
Prohibition of Frequency Increase
(Only Frequency Decrease Permitted) 12, 14, 22 and 24 44.5 45.5 46.0 47.0 48.0
Iinv < I2 (A)
Iinv ≥ I3 (A) ˂380V˃
Outdoor Unit Model [HP] I1 I2 I3 I4 I5
Frequency Forced Decrease 8, 10, 16 to 20 18.0 18.5 19.0 19.5 19.5
(3.0Hz/sec.) Iinv < I4 (A) 12, 14, 22 and 24 24.5 25.0 25.5 26.0 26.0

Iinv ≥ I5 x 105% (A) for 30 sec. ˂460V˃


or totally 3 min. in 10 min. Outdoor Unit Model [HP] I1 I2 I3 I4 I5
8, 10, 16 to 20 17.5 18.0 18.5 19.0 19.0
Abnormal Stoppage 12, 14, 22 and 24 22.5 23.0 23.5 24.0 24.0
(Cause Code of Inverter Stoppage: d1-17)

NOTE:
1. With a combination of base units, the control in the figure is performed for each outdoor unit connected. When there is
outdoor unit in Prohibition of Frequency Increase, all the outdoor units in operation are prohibited to increase frequency.
When there is outdoor unit in Frequency Forced Decrease, all the outdoor units in operation are forced to decrease
frequency.
2. In case of two inverter PCB installed in an outdoor unit, the max. current value detected at each inverter PCB is utilized.
Iinv: Detected Value of Inverter Secondary Current Sensor[A]

1-162 FAN-2209 201709


CONTROL SYSTEM

(b) Primary Current Protection for each Inverter PCB

˂Details of Control˃ Control Value


˂220V˃
Normal Operation Outdoor Unit Model [HP] I1 I2 I3 I4
8, 10, 16 to 20 38.0 39.5 39.5 40.0
Isep ≦ I2 (A) Isep ≧ I1 (A)
12, 14, 22 and 24 48.0 49.5 49.5 50.0

Prohibition of Frequency Increase ˂380V˃


(Only Frequency Decrease Permitted) Outdoor Unit Model [HP] I1 I2 I3 I4
Isep ≧ I3 (A) Isep ≦ I4 (A) 8 to 24 26.5 27.5 27.5 28.0
˂460V˃
Frequency Forced Decrease Outdoor Unit Model [HP] I1 I2 I3 I4
(1.0Hz/sec.)
8 to 24 23.5 24.5 24.5 25.0

NOTE:
1. With a combination of base units, the control in the figure is performed for each outdoor unit connected. When there is
outdoor unit in Prohibition of Frequency Increase, all the outdoor units in operation are prohibited to increase frequency.
When there is outdoor unit in Frequency Forced Decrease, all the outdoor units in operation are forced to decrease
frequency.
2. In case of two inverter PCB installed in an outdoor unit, the max. current value detected at each inverter PCB is utilized.
Isep: Inverter Primary Current[A]

(c) Primary Current Protection for each Outdoor Unit

˂Details of Control˃ Control Value


˂220V˃
Normal Operation Outdoor Unit Model
I1 I2 I3 I4
[HP]
Idou ≦ I2 (A) Idou ≧ I1 (A) 8 21.9 23.4 23.4 23.9
10 31.1 32.6 32.6 33.1
Prohibition of Frequency Increase 12 34.8 36.3 36.3 36.8
(Only Frequency Decrease Permitted) 14 43.5 45.0 45.0 45.5
16 49.5 51.0 51.0 51.5
Idou ≧ I3 (A)
Idou ≦ I4 (A) 18 56.4 57.9 57.9 58.4
20 67.0 68.5 68.5 69.0
Frequency Forced Decrease 22 67.9 69.4 69.4 69.9
(1.0Hz/sec.)
24 80.8 82.3 82.3 82.8
˂380V˃
Outdoor Unit Model
I1 I2 I3 I4
[HP]
8 13.0 14.0 14.0 14.5
10 18.6 19.6 19.6 20.1
NOTE: 12 20.9 21.9 21.9 22.4
1. With a combination of base units, the control in the figure is 14 26.2 27.2 27.2 27.7
performed for each outdoor unit connected. When there is outdoor 16 29.8 30.8 30.8 31.3
unit in Prohibition of Frequency Increase, all the outdoor units 18 34.0 35.0 35.0 35.5
in operation are prohibited to increase frequency. When there is
20 40.5 41.5 41.5 42.0
outdoor unit in Frequency Forced Decrease, all the outdoor units in
operation are forced to decrease frequency. 22 41.0 42.0 42.0 42.5
24 48.9 49.9 49.9 50.4
Idou: Total Value of Primary Current of all the Inverter PCB in an
Outdoor Unit[A] ˂460V˃
Outdoor Unit Model
I1 I2 I3 I4
[HP]
8 11.5 12.5 12.5 13.0
10 16.5 17.5 17.5 18.0
12 18.5 19.5 19.5 20.0
14 23.2 24.2 24.2 24.7
16 26.5 27.5 27.5 28.0
18 30.2 31.2 31.2 31.7
20 36.0 37.0 37.0 37.5
22 36.5 37.5 37.5 38.0
24 43.5 44.5 44.5 45.0

FAN-2209 201709 1-163


CONTROL SYSTEM

(4) P04: Inverter Fin Temperature Increase Protection Control


Inverter Fin Temperature Increase Protection Control is performed in order to prevent an inverter trip
caused by a temperature increase of the inverter fin.
˂Detail of Control˃
Normal Operation Control Value
˂220V˃ [°C(°F)]
Tfin ≥ T1
Outdoor Unit Model [HP] T1 T2 T3 T4 T5
Prohibition of Frequency Increase 98 96 100 98 106
(Only Frequency Decrease Permitted) 8, 10, 16 to 20
Tfin < T2 (208) (205) (212) (208) (223)
103 101 105 103 111
Tfin ≥ T3 12, 14, 22 and 24
(217) (214) (221) (217) (232)
Frequency Forced Decrease
(0.5Hz/sec.) ˂380V˃ <460V> [°C(°F)]
Tfin < T4 Model T1 T2 T3 T4 T5
Tfin ≥ T5
102 100 104 102 110
8 to 24
Abnormal Stoppage (216) (212) (220) (216) (230)
(Cause Code of I.U. Stoppage: d1-17)

NOTE:
1. In case of combination of base units, the control in the figure is performed for each outdoor unit connected. When there is
outdoor unit in Prohibition of Frequency Increase, all the outdoor units in operation are prohibited to increase frequency.
When there is outdoor unit in Frequency Forced Decrease, all the outdoor units in operation are forced to decrease
frequency.
2. In case of two inverter PCB installed in an outdoor unit, the max. temperature detected at each inverter PCB is utilized.
Tfin: Inverter Fin Temperature Sensor Detected Value [°C(°F)]

(5) P05: Discharge Temperature Increase Protection Control


Discharge Temperature Increase Protection Control is performed in order to protect the compressor
motor coil from an increase of discharge temperature during an abnormality.
Details of Control
Normal Operation

Td ≥ 112°C(234°F)

Frequency Forced Decrease


(1.0Hz/sec.)

Td < 110°C(230°F) Td ≥ 112°C Td > 140°C(284°F) for 5 sec. or


(234°F) Td > 132°C(270°F) for 10 min.
Prohibition of Frequency Increase
(Only Frequency Decrease Permitted) Abnormal Stoppage
(Cause Code of I.U. Stoppage: d1-15)
Td < 105°C(221°F)
NOTE:
1. With a combination of base units, the control in the figure is performed for the entire number of outdoor units to be connected.
2. Discharge temperature is detected in each outdoor unit, and this control uses the maximum value.
3. In case of two inverter compressors installed in an outdoor unit, the max. temperature detected at each inverter compressor
is utilized.
Td: Detected Value of Discharge Gas Thermistor [°C(°F)]

(6) P06: Low Pressure Decrease Protection Control


Low Pressure Decrease Protection Control is performed in order to protect the compressor from a
transitional decrease of suction pressure.
˂Details of Control˃
Normal Operation

Ps < 0.10MPa (15psi)

Frequency Forced Decrease


(0.25Hz/sec.)
Ps < 0.09MPa (13psi) for 12 min.
Ps > 0.15MPa (22psi) Ps < 0.10MPa
(15pis)
Prohibition of Frequency Increase
(Only Frequency Decrease Permitted) Abnormal Stoppage
(Cause Code of I.U. Stoppage: d1-15)
Ps > 0.20MPa (29psi)
NOTE:
1. With a combination of base units, the control in the figure is performed for the entire number of outdoor units to be connected.
2. Low pressure is detected in each outdoor unit, and this control uses the minimum value.
Ps: Detected Value of Low Pressure Sensor [MPa(pis)]

1-164 FAN-2209 201709


CONTROL SYSTEM

(7) P09: High Pressure Decrease Protection Control


When decreasing high pressure, the compressor operation frequency is controlled by this protection
control for the following purposes.
• To prevent insufficient refrigerant supply to indoor units installed at different height locations.
• To keep the refrigerant oil supply in the compressor.
Details of Control
Normal Operation

Pd < 1.0MPa (145psi)

Frequency Forced Increase


(0.125Hz/sec.)
Pd < 1.0MPa (145psi) for 1 hr.
Pd > 1.2MPa (174psi) Ps < 1.0MPa
(145psi)
Prohibition of Frequency Decrease
(Only Frequency Increase Permitted) Abnormal Stoppage
(Cause Code of I.U. Stoppage: d1-26)
Pd > 1.5MPa (218psi)
NOTE:
1. With a combination of base units, the control in the figure is performed for the entire number of outdoor units to be connected.
2. High pressure is detected in each outdoor unit, and this control uses the minimum value.
Pd: Detected Value of High Pressure Sensor [MPa(psi)]

(8) P0A: Demand Current Control


The compressor operation frequency is controlled to set at the setting value of the outdoor unit inverter
primary current (40% to 100% of rated current of cooling operation). This function is detailed in the
“External Input and Output Setting”. Refer to the Service Manual for details.
Operating Conditions
The demand current control can be performed under the following conditions.
(a) The demand signal is input from the centralized operation controller.
(b) The demand signal is input at the external input terminals of the outdoor unit from external
equipment such as a building management system or a utility with a smart meter.
(c) The demand function settings are set from the outdoor unit PCB.
(d) The wave function is set from the outdoor unit PCB.
(e) The demand signal is input from the indoor unit (wired controller).
If the operation current exceeds each setting function value, the compressor operation frequency is
controlled.
Cancellation Condition
The input signal is stopped at each condition (a) to (e).
NOTE:
This function is not available when the compressor starts or during a defrosting operation.

(9) P0d: Low Pressure Increase Protection Control


The compressor operation frequency is controlled to protect the compressor from suction pressure
transitional increasing.
Details of Control
Normal Operation

Ps ≥ 1.3MPa (189psi)

Frequency Forced Increase


(0.125Hz/sec.)
Ps < 1.4MPa (203psi) for 1 min.
Ps ≤ 1.29MPa (187psi) Ps ≥ 1.3MPa
(189psi)
Prohibition of Frequency Decrease
(Only Frequency Increase Permitted) Abnormal Stoppage
(Cause Code of I.U. Stoppage: d1-12)
Ps ≤ 1.24MPa (180psi)

NOTE:
1. With a combination of base units, the control in the figure is performed for the entire number of outdoor units to be connected.
2. Low pressure is detected in each outdoor unit, and this control uses the maximum value.
Ps: Detected Value of Low Pressure Sensor [MPa(psi)]

FAN-2209 201709 1-165


CONTROL SYSTEM

(10) Priority of Protection Control


If two or more protection controls meet a condition, the protection controls perform according to
the following.

Rank Order. Indication Protection Control Performed


1 P01 Pressure Ratio Protection Control
2 P02 High Pressure Increase Protection Control
3 P03 Inverter Current Protection Control
4 P04 Inverter Fin Temperature Increase Protection Control
5 P05 Discharge Temperature Increase Protection Control
6 P06 Low Pressure Decrease Protection Control
7 P0A Demand Current Control
8 P0d Low Pressure Increase Protection Control
9 P09 High Pressure Decrease Protection Control

2 Lower Rank Order of Protection Control Function

Forced Forced Prohibition Prohibition


Decrease Increase of Increase of Decrease

Forced Decrease 1 1 1 1
1
Forced Increase 1 1 1 1
Higher Rank Order
of Protection Prohibited Increase 2 1 2 * 1
Control Function
Prohibited Decrease 2 2 2 2
*: Discharge Temperature Increase Protection Control (P05) is higher than the following protection controls.
a) Low Pressure Decrease Protection Control (P06)
b) Demand Current Control (P0A)

(11) Degeneration Control


Degeneration Control is performed to change the protection control range.
This control sequence will suppress re-occurring alarms in response to repeated equipment restarts
during protection control conditions listed below.

Related Protection Control


(1) Pressure Ratio Decrease Protection Control (P01)
(2) High Pressure Increase Protection Control (P02)
(3) Inverter Current Protection Control (P03)
(4) Inverter Fin Temperature Increase Protection Control (P04)
(5) Discharge Temperature Increase Protection Control (P05)

˂Example of Discharge Temperature Increase Protection Control˃

Normal Operation
Normal: Td > 112°C(234°F)
Degeneration: Td > 110°C(230°F) Td > 140°C(284°F) for 5 sec. or
Td > 132°C(270°F) for 10 min.
Frequency Forced Decrease
(1.0Hz/sec.)
Normal: Td < 110°C(230°F) Normal: Td > 112°C(234°F)
Degeneration: Td < 108°C(226°F) Degeneration: Td > 110°C(230°F)
Prohibition of Frequency Increase
(Except Frequency Decrease Only)
Abnormal Stoppage
(Cause Code of I.U. Stoppage: d1-15)
Normal: Td < 105°C(221°F)
Degeneration: Td < 100°C( 212°F)

1-166 FAN-2209 201709


CONTROL SYSTEM

(12) Oil Return Control


Oil return control is performed in order to avoid insufficient oil supply to the compressor caused by long
time low frequency operation. This control is utilized to return the oil flow out to the indoor unit side
from the compressor.

˂Activating Condition˃
This control function is started the compressor runs below the specified speed for 1 hour continuously
(refer to the table below).

˂Compressor Speed for Oil Return Control˃ [Hz]


Outdoor Unit Cooling Operation Heating Operation
≤ 8HP 32.0 32.0
10HP 38.0 38.0
12HP, 14HP 50.0 54.0
16HP to 24HP 66.0 72.0
26HP to 36HP 96.0 108.0
38HP ≤ 132.0 156.0

˂Detail of Control˃
Compressor:
Increase the compressor speed above the required value to return the oil to the compressor
Expansion Valve:
(In the Case of Cooling Operation) Open the expansion valve of the indoor unit under thermo-ON.
(In the Case of Heating Operation) Open the expansion valve of the outdoor unit.

˂Deactivating Condition˃
This control function is canceled when the oil return control continues for more than 60 sec. (for cooling
operation) /120sec. (for heating operation).

FAN-2209 201709 1-167


CONTROL SYSTEM

12.4 Safety and Control Device Setting

• Compressor Protection
The compressor is protected by the following devices and their combinations.
(1) High Pressure Switch: This switch cuts out the operation of the compressor when the discharge
pressure exceeds the setting.
(2) Oil Heater: This band type heater protects against oil foaming during cold starting, as it is energized
while the compressor is stopped.

JTOR080VPE JTOR100VPE JTOR120VPE JTOR140VPE JTOR160VPE


Model
(U, F, R) BS1 (U, F, R) BS1 (U, F, R) BS1 (U, F, R) BS1 (U, F, R) BS1
For Compressor Automatic Reset, Non-Adjustable
Pressure Switches (each one for each compressor)
-0.05 -0.05 -0.05 -0.05 -0.05
High Cut-Out MPa 4.15 4.15 4.15 4.15 4.15
-0.15 -0.15 -0.15 -0.15 -0.15
Cut-In MPa 3.20­+0.15 3.20+0.15 3.20+0.15 3.20+0.15 3.20+0.15
Fuse Capacity
3~, 220V, 60Hz A 70 70 80 80 70
3~, 460V, 60Hz
3N~, 380V, 60Hz A 50 50 50 50 50
Oil Heater
Capacity W 37.3 x 3 37.3 x 3 37.3 x 3 37.3 x 3 37.3 x 6
CCP Timer Non-Adjustable
Setting Time min. 3 3 3 3 3
For DC Fan Module
Fuse Capacity
3~, 220V, 60Hz A 10 10 10 10 10
3~, 460V, 60Hz
3N~, 380V, 60Hz A 5 5 5 10 5

JTOR180VPE JTOR200VPE JTOR220VPE JTOR240VPE


Model
(U, F, R) BS1 (U, F, R) BS1 (U, F, R) BS1 (U, F, R) BS1
For Compressor Automatic Reset, Non-Adjustable
Pressure Switches (each one for each compressor)
-0.05 -0.05 -0.05 -0.05
High Cut-Out MPa 4.15 4.15 4.15 4.15
-0.15 -0.15 -0.15 -0.15
Cut-In MPa 3.20­+0.15 3.20+0.15 3.20+0.15 3.20+0.15
Fuse Capacity
3~, 220V, 60Hz A 70 70 80 80
3~, 460V, 60Hz
3N~, 380V, 60Hz A 50 50 50 50
Oil Heater
Capacity W 37.3 x 6 37.3 x 6 37.3 x 6 37.3 x 6
CCP Timer Non-Adjustable
Setting Time min. 3 3 3 3
For DC Fan Module
Fuse Capacity
3~, 220V, 60Hz A 10 10 10 10
3~, 460V, 60Hz
3N~, 380V, 60Hz A 5 5 5 5

1-168 FAN-2209 201709


CONTROL SYSTEM

12.5 Electrical Wiring Diagram


12.5.1 Outdoor Units
ELECTRICAL WIRING DIAGRAM (FOR MODEL: JTOR080VPEUBS1, JTOR100VPEUBS1 and JTOR120VPEUBS1; 460V/60HZ)

FAN-2209 201709 1-169


CONTROL SYSTEM

ELECTRICAL WIRING DIAGRAM (FOR MODEL: JTOR140VPEUBS1; 460V/60HZ)

1-170 FAN-2209 201709


CONTROL SYSTEM

ELECTRICAL WIRING DIAGRAM (FOR MODEL: JTOR160VPEUBS1 and JTOR180VPEUBS1; 460V/60HZ)

FAN-2209 201709 1-171


CONTROL SYSTEM

ELECTRICAL WIRING DIAGRAM (FOR MODEL: JTOR200VPEUBS1, JTOR220VPEUBS1 and JTOR240VPEUBS1; 460V/60HZ)

1-172 FAN-2209 201709


CONTROL SYSTEM

ELECTRICAL WIRING DIAGRAM (FOR MODEL: JTOR080VPEFBS1, JTOR100VPEFBS1 and JTOR120VPEFBS1; 380V/60HZ)

FAN-2209 201709 1-173


CONTROL SYSTEM

ELECTRICAL WIRING DIAGRAM (FOR MODEL: JTOR140VPEFBS1; 380V/60HZ)

1-174 FAN-2209 201709


CONTROL SYSTEM

ELECTRICAL WIRING DIAGRAM (FOR MODEL: JTOR160VPEFBS1 and JTOR180VPEFBS1; 380V/60HZ)

FAN-2209 201709 1-175


CONTROL SYSTEM

ELECTRICAL WIRING DIAGRAM (FOR MODEL: JTOR200VPEFBS1, JTOR220VPEFBS1 and JTOR240VPEFBS1; 380V/60HZ)

1-176 FAN-2209 201709


CONTROL SYSTEM

ELECTRICAL WIRING DIAGRAM (FOR MODEL: JTOR080VPERBS1, JTOR100VPERBS1 and JTOR120VPERBS1; 220V/60HZ)

FAN-2209 201709 1-177


CONTROL SYSTEM

ELECTRICAL WIRING DIAGRAM (FOR MODEL: JTOR140VPERBS1; 220V/60HZ)

1-178 FAN-2209 201709


CONTROL SYSTEM

ELECTRICAL WIRING DIAGRAM (FOR MODEL: JTOR160VPERBS1 and JTOR180VPERBS1; 220V/60HZ)

FAN-2209 201709 1-179


CONTROL SYSTEM

ELECTRICAL WIRING DIAGRAM (FOR MODEL: JTOR200VPERBS1, JTOR220VPERBS1 and JTOR240VPERBS1; 220V/60HZ)

1-180 FAN-2209 201709


CONTROL SYSTEM

12.5.2 CH-Box

ELECTRICAL WIRING DIAGRAM (FOR MODEL: JCH-AP160SSX, JCH-AP280SSX)

This part is not


equipped for
Mexico model.

FAN-2209 201709 1-181


CONTROL SYSTEM

ELECTRICAL WIRING DIAGRAM (FOR MODEL: JCH-AP04MSSX)

This part is not


equipped for
Mexico model.

1-182 FAN-2209 201709


CONTROL SYSTEM

ELECTRICAL WIRING DIAGRAM (FOR MODEL: JCH-AP08MSSX)

* : This part is not equipped for Mexico model.

FAN-2209 201709 1-183


CONTROL SYSTEM

ELECTRICAL WIRING DIAGRAM (FOR MODEL: JCH-AP12MSSX)

* : This part is not equipped for Mexico model.

1-184 FAN-2209 201709


CONTROL SYSTEM

ELECTRICAL WIRING DIAGRAM (FOR MODEL: JCH-AP16MSSX)

* : This part is not equipped for Mexico model.

FAN-2209 201709 1-185


MISCELLANEOUS NOTES

13. Miscellaneous Notes

Special Notes
1. Provide a service access door near the unit 10. During heating operation, the outdoor heat
piping connection part on the false ceiling for the exchanger produces dew condensation or
cassette type units. melted frost water.
2. Consider the air distribution from the unit to the Install the outdoor unit where such water can
space of the room, and select a suitable location be drained, or provide a drain passage.
so that uniform air temperature in the room can 11. Heating Performance: The heating capacity
be obtained. normally decreases when outdoor temperatures
Cassette and Ceiling Types - Avoid unit decrease. Therefore, provide an auxiliary
installation in a room where the ceiling height heating unit if outdoor temperatures are very
(distance between the floor to the false ceiling) low.
exceeds three meters. If the indoor unit is 12. In the case that an outdoor temperature is
installed in a room with a ceiling more than three low and humidity is high, the outdoor heat
meters in height, it is recommended that an air exchanger will be covered with frost, resulting
circulation fan be installed separately to obtain in lower heating capacity. In order to remove
uniform air temperature in the room, especially the frost, the unit operation mode automatically
during the heating operation. changes to the defrosting mode. During
3. Check to ensure that the ceiling slab is strong this defrosting operation, the unit stops for
enough and that the false ceiling is flat and level. approximately 3 to 10 minutes.
4. Avoid obstacles which may restrict the air intake 13. As this unit is heat pump type by circulating hot
or the discharge flow. air in the whole room space, it takes some time
5. Do not install the unit in a machinery shop or to raise the room temperature.
kitchen where vapor from oil or its mist can enter 14. The operating sound data is based on an
the unit. anechoic chamber. Therefore, the actual
The oil will deposit on the heat exchanger, operating sound will be higher due to reflected
which may reduce the unit performance, cause sound from the floor and wall.
deformation, and in the worst case, break the 15. In the case that the unit is operated for
plastic parts of the unit. a long time at an indoor temperature of over
6. Pay attention to the following points when the 27oC DB, or at an indoor humidity of over 80%,
unit is installed in a hospital or other facilities dew condensation may occur on the cabinets,
where electromagnetic wave is radiated from resulting in dew drops.
medical equipment. If dew condensation occurs, it is required to
(A) Do not install the unit where the add thermal insulator on the cabinets.
electromagnetic wave is directly radiated to 16. Provide snow-protection hoods to prevent snow
the electrical box, remote control cable or from clogging the outdoor heat exchanger.
remote control switch. If the unit is operated in an area where it snows
(B) Install the unit and components as far from heavily, provide a base under the outdoor
an electromagnetic wave radiator (at least unit, which should be 50cm higher than the
three meters) as possible. presumable maximum snow height.
(C) Prepare a steel box and install the remote 17. It is recommended that periodical service and
control switch in it. Prepare a steel conduit maintenance be performed by authorized
pipe and wire the remote control cable in it. service engineers before air conditioning
And then, connect earth wire with the box seasons, in order to avoid performance
and the pipe. decrease due to dust or dirt.
(D) Install a noise filter when the power supply 18. This heat pump air conditioner has been
emits harmful noise. designed for normal air conditioning for men.
7. Do not install the units in an acid or alkaline Do not use the product for other purposes such
environment, as the heat exchanger will be as for food, animals, plants, high precision
damaged by corrosive action. In the case that machines or work of art. Also do not use the
outdoor units are installed near the sea, it is product for vehicles or vessels. It will results in
recommended that optional corrosion-resistant- water leakage or electrical leakage.
type outdoor unit be used. 19. It is recommended that the system be installed
8. Do not install the units in a flammable by authorized engineers. If not, it may cause
environment, as there is a danger of an water leakage, electric shock or fire.
explosion. 20. In a place where fibers or dusts are floating, the
9. Regarding cassette type indoor units, consider air filter or heat exchangers or the drain pipe
the direct and reflected sound level, when may be clogged, resulting in water leakage
selecting the unit for spaces where extremely from the drain pan.
low sound is required.

1-186 FAN-2209 201709


STANDARD SPECIFICATIONS

14. Standard Specifications

UNIT - The unit shall be a multi-split system OUTDOOR UNIT


inverter-driven heat pump air conditioner for
application with R410A refrigerants, and shall be CABINET - The cabinet shall be constructed of
composed of 4-way cassette type indoor units, galvanized steel sheet, baked with synthetic resin
or in-the-ceiling type indoor units, 2-way cassette paint. The service panel shall be easily removable
type indoor units, ceiling type indoor units, wall for service access to the electrical components and
type indoor units, floor type indoor units and an the compressor section.
outdoor unit, with a distributed refrigeration cycle,
electrical components and enclosing cabinets. REFRIGERATION CYCLE - Each refrigeration
Optional accessories shall also be provided cycle shall be equipped with (a) scroll
upon customer request. The indoor unit shall be compressor(s), a solenoid valve, a heat exchanger,
constructed for installation, and the outdoor unit an accumulator, a 4-Way valve and flare
shall be completely weather-proofed for outdoor connection parts.
installation. Both indoor unit and the outdoor unit
shall be properly assembled, internally piped and COMPRESSOR PROTECTION - The compressor
wired, throughly tested, and charged with R410A shall be protected against breakdown by a quick
refrigerant at the factory and shall comply with response overcurrent relay, a high pressure switch,
Japanese Industrial Standards and other Japanese a wrap-around type oil heater and a discharge gas
standardization statues. thermistor.

CAPACITY - The total capacity of the multi-split OUTDOOR FAN AND FAN MOTOR - The
system inverter-driven heat pump air conditioner outdoor fan(s) shall be the plastic propeller type,
o
shall be kW or greater with C air dynamically balanced, and the fan shall be directly
o o
inlet dry bulb, C air inlet wet bulb, C driven by a W motor for vertical-flow air
3
outdoor air inlet temperature and m /min. discharge. The fan motor shall be permanently
indoor air flow. The total compressor power inputs lubricated and be protected from ingress of water.
shall not exceed kW. The total heating
capacity of the split-type air conditioners shall be OUTDOOR HEAT EXCHANGER - The heat
o
kW or greater, with C indoor heat exchanger shall be the multi-pass, cross-finned
o
exchanger air inlet dry bulb, C outdoor heat tube type, equipped with highly-efficient aluminum
o
exchanger air inlet dry bulb, C outdoor heat fins, mechanically bonded to oxygen-free copper
exchanger air inlet wet bulb, and m3/min. tubes. The coil shall be cleaned, dehydrated and
indoor air flow. tested for leakage at the factory.
The total compressor power input shall not exceed
kW. CONTROL - All electrical control devices, shall be
enclosed in the indoor and outdoor units.

In addition to the compressor protection devices,


the indoor fan motor shall be equipped with an
internal thermostat. The outdoor fan motor shall
be protected by an internal thermostat. The indoor
fan motor shall be directly supplied with the power
source from the control circuit. The functions of
these control devices shall compose an electrical
sequence of manual starting and stopping,
automatic continuous operation whenever the room
thermostat requires, and the protection devices
allow the operation.

CABINET - The cabinet shall be constructed of


galvanized steel sheet.

REFRIGERATION CYCLE - The refrigeration cycle


shall be equipped with solenoid valves and flare
connections to changeover the cycle in mediating
between outdoor unit and indoor unit.

FAN-2209 201709 1-187


CAUTION

15. Caution on Refrigerant Leakage

The room where the packaged air conditioner is installed, the refrigerant gas should be controlled not to
exceed the limit concentration in case of the refrigerant leakage.

15.1 Maximum Permissible Concentration of HFC Gas


The refrigerant R410A of incombustible and non-toxic is adopted with this unit. If by any chance the
refrigerant gas is leaked and filled in the room, the possibility of suffocation may occur.
Especially for the YORK VRF system, the outdoor unit is multi-type air conditioner by connecting multiple
indoor units with long distance piping. Accordingly, the refrigerant charging quantity is larger than general
individual unit. Before the indoor unit installation, confirm that the room can keep the lower gas concentration
than the limit value in order to take the emergency countermeasures even if the gas leakage is occurred.

15.2 Calculation of Refrigerant Concentration


(1) Calculate the total quantity of refrigerant R (kg) charged in the system connecting all the indoor units
of rooms to be air-conditioned.
(2) Calculate the room Volume V (m3) of each room.
(3) Calculate the refrigerant concentration C (kg/m3) of the room according to the following equation.
R: Total Quantity of Charged Refrigerant (kg)
= C: Refrigerant Concentration
V: Room Space for each Indoor Unit (m3) 3

< 0.42 (kg/m ) for R410A

The refrigerant R410A is non-toxic and inflammable in its original state.


However, in consideration of a state where the refrigerant leaks into the room, measures against
refrigerant leaks must be taken in small rooms where the tolerable level could be exceeded.
Take countermeasures by installing ventilation devices,etc.

250

Range below the


200 density
limit of 0.42kg/m3
Room Volume (m3)

(Countermeasures
Not Needed)
150

Range above the limit of


100 0.42kg/m3
(Countermeasures Needed)

50

0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150

Total Quantity Charged of Refrigerant (kg)

1-188 FAN-2209 201709


CAUTION

After calculation, the room to install this unit is proved not to keep the gas concentration lower than the limit
value. However, the air conditioner should be installed in this room from unavoidable circumstances, each
of the following countermeasures should be taken.

Outdoor Unit

Refrigerant Flow
Refrigerant Cycle

Indoor Unit

Room where the refrigerant leakage occurs


(Whole refrigerant in the cycle flows out.)

1) The gas leakage detector & alarm system and interlocking mechanical ventilation equipment (with
ventilation capacity over 0.42m3/min per refrigerating ton) should be installed. Refer to the following
figure.

Outdoor Unit Refrigerating Outdoor Unit Refrigerating


(HP) Ton (HP) Ton
8 3.08 32 12.31
10 3.69 34 13.12
12 4.52 36 13.94
14 5.34 38 14.38
16 6.15 40 15.60
18 6.97 42 16.01
20 7.59 44 17.26
22 8.63 46 17.67
24 9.04 48 18.08
26 9.86 50 19.28
28 10.67 52 19.61
30 11.49 54 19.93

2) Provide the opening for ventilation between rooms* in order not to exceed the permissible
concentration.
* It is opening without door or opening at the top or bottom of door with floor space more than 0.15%.

● Example Refrigerant Piping


Refrigerant Charge: 60kg

Outdoor Unit

Indoor Unit
The Smallest
Room

Medium-sized
Small Room Room Large Room

Mechanical Ventilation Equipment + Gas Leakage Detector & Alarm System

NOTES:
1. The quantity of refrigerant gas leakage against each room should be calculated as 60kg each.
2. The refrigerant concentration must be below 0.42 kg/m3 for each room.

The installer and system specialist shall secure against leakage according to local regulations or
standards. The following standards may be applicable, if local regulations are not available.
International Organization for Standardization, ISO5149 or European Standard, EN378 or Japan
Standard, KHKS0010.

FAN-2209 201709 1-189


Installation and Maintenance

- CONTENTS -

● Outdoor Units (FAN-2208 201709)............................................................................................................. 2-3


● Piping Connection Kit <3 pipes>: MC-NP20 - 30SX (P5417030)............................................................... 2-95
● Multi-Kit (Line Branch) <3 pipes>: MW-NP142 - 902X3 (P5416979).......................................................... 2-100
● Multi-Kit (Line Branch) <2 pipes>: MW-NP282 - 902A3 (P5416978).......................................................... 2-106
● Multi-Kit (Header Branch) <3 pipes>: JMH-NP288X (FAN-1593 201607 <P5416738>)............................ 2-111
● Multi-Kit (Header Branch) <2 pipes>: JMH-NP224A, 280A (FAN-1591 201607 <P5416736>).................. 2-115
● Drain Boss: DBS-TP10A (P5414717)......................................................................................................... 2-119
● Air Inlet Grille: PSN-TP20** (P5416988 - P5416991)................................................................................. 2-121
● Protection Net: PN-TP20** (P5416992 - P5416995).................................................................................. 2-133
● CH-Box <Single Branch Type> (FAN-2212 201711 <P5417023>)............................................................. 2-146
● CH-Box <Multiple Branch Type> (FAN-2213 201711 <P5417025>)........................................................... 2-173

FAN-2209 201709 2-1


2-2 FAN-2209 201709
OUTDOOR UNIT

VRF OUTDOOR UNITS


INSTALLATION AND
New Release Form FAN-2207 201709
MAINTENANCE MANUAL

INVERTER-DRIVEN
MULTI-SPLIT SYSTEM HEAT RECOVERY
AIR CONDITIONERS

Models:
< 3~, 460V/60Hz > < 3~/N, 380V/60Hz > < 3~, 220V/60Hz >
< Base Unit > < Base Unit > < Base Unit >
JTOR080VPEUBS1 JTOR080VPEFBS1 JTOR080VPERBS1
JTOR100VPEUBS1 JTOR100VPEFBS1 JTOR100VPERBS1
JTOR120VPEUBS1 JTOR120VPEFBS1 JTOR120VPERBS1
JTOR140VPEUBS1 JTOR140VPEFBS1 JTOR140VPERBS1
JTOR160VPEUBS1 JTOR160VPEFBS1 JTOR160VPERBS1
JTOR180VPEUBS1 JTOR180VPEFBS1 JTOR180VPERBS1
JTOR200VPEUBS1 JTOR200VPEFBS1 JTOR200VPERBS1
JTOR220VPEUBS1 JTOR220VPEFBS1 JTOR220VPERBS1
JTOR240VPEUBS1 JTOR240VPEFBS1 JTOR240VPERBS1

< Combination Unit > < Combination Unit > < Combination Unit >
JTOR260VAEUBS1 JTOR260VAEFBS1 JTOR260VAERBS1
JTOR280VAEUBS1 JTOR280VAEFBS1 JTOR280VAERBS1
JTOR300VAEUBS1 JTOR300VAEFBS1 JTOR300VAERBS1
JTOR320VAEUBS1 JTOR320VAEFBS1 JTOR320VAERBS1
JTOR340VAEUBS1 JTOR340VAEFBS1 JTOR340VAERBS1
JTOR360VAEUBS1 JTOR360VAEFBS1 JTOR360VAERBS1
JTOR380VAEUBS1 JTOR380VAEFBS1 JTOR380VAERBS1
JTOR400VAEUBS1 JTOR400VAEFBS1 JTOR400VAERBS1
JTOR420VAEUBS1 JTOR420VAEFBS1 JTOR420VAERBS1
JTOR440VAEUBS1 JTOR440VAEFBS1 JTOR440VAERBS1
JTOR460VAEUBS1 JTOR460VAEFBS1 JTOR460VAERBS1
JTOR480VAEUBS1 JTOR480VAEFBS1 JTOR480VAERBS1
JTOR500VAEUBS1 JTOR500VAEFBS1 JTOR500VAERBS1
JTOR520VAEUBS1 JTOR520VAEFBS1 JTOR520VAERBS1
JTOR540VAEUBS1 JTOR540VAEFBS1 JTOR540VAERBS1

Issue Date:
15. Dec. 2017

FAN-2209 201709 2-3


OUTDOOR UNIT

IMPORTANT NOTICE

l YORK pursues a policy of continuing improvement in design and performance of products.


The right is therefore reserved to vary specifications without notice.
l YORK cannot anticipate every possible circumstance that might involve a potential hazard.
l This heat pump air conditioner is designed for standard air conditioning only. Do not use this heat pump
air conditioner for other purpose such as drying clothes, refrigerating foods or for any other cooling or
heating process.
l Do not install the unit in the following places. It may cause a fire, deformation, corrosion or failure.
* Places where oil (including machinery oil).
* Places where a lot of sulfide gas drifts such as in hot spring.
* Places where inflammable gas may generate or flow.
* Places where strong salty wind blows such as coast regions.
* Places with an atmosphere of acidity or alkalinity.
l Do not install the unit in the place where silicon gas drifts. If the silicon gas attaches to the surface of heat
exchanger, the fin surface repels water. As a result, drain water splashes outside of the drain pan and
splashed water runs inside of electrical box. In the end, water leakage or electrical devices failure may
occur.
l Pay attention to the following points when the unit is installed in a hospital or other facilities where
electromagnetic wave generates from medical equipment.
* Do not install the unit in the place where the electromagnetic wave is directly radiated to the electrical
box, controller cable or wired controller.
* Install the unit at least 3 meters away from electromagnetic wave such as a radio.
l Do not install the unit in the place where the breeze directly catches the animals and plants. It could
adversely affect the animals and plants.
l We strongly suggest to select the units with considering performance deterioration, as well as servicing,
maintenance and periodic electrical parts replacement if install the units to the altitude above 2,000m. We
also would like to request announcement of the fact to dealers.
l The installer and system specialist shall secure against leakage according to local regulations or
standards. The following standards may be applicable, if local regulations are not available.
International Organization for Standardization, ISO5149 or European Standard, EN378 or Japan Standard,
KHKS0010.
l No part of this manual may be reproduced without written permission.
l It is assumed that this heat pump air conditioner will be operated and serviced by English speaking people.
If this is not the case, the customer should be add safety, caution and operating signs in the native
language.
l If you have any questions, contact your distributor or dealer of YORK.
l This manual gives a common description and information for this heat pump air conditioner which you
operate as well for other models.

FAN-2207 201709 i

2-4 FAN-2209 201709


OUTDOOR UNIT

l This heat recovery air conditioner has been designed for the following temperatures. Operate the heat
recovery air conditioner within this range.
l This system can provide Heat Recovery System.

Temperature (°C)
Cooling and Heating Operation
Cooling Operation Heating Operation
Cooling Heating
Indoor Air Inlet
15 to 23°C WB 15 to 27°C DB 15 to 23°C WB 15 to 27°C DB
Temperature

-5 to 24°C DB
-5 to 48°C DB
-6 to 15°C WB
Outdoor Air Inlet
With Low Ambient Setting* -20 to 15°C WB With Low Ambient Setting*
Temperature
-10 to 24°C DB
-10 to 48°C DB
-11 to 15°C WB
DB: Dry Bulb, WB: Wet Bulb

(*) NOTES:
1. Cooling operation at maximum 48°C DB should be available only if the outdoor air inlet temperature
increase temporarily according to the installation condition.
2. If install the units to the place where exceed ambient temperature 48°C DB continuously, the combination
ratio must be lower 130%, and not to operate all of the indoor unit simultaneously.
3. The cooling capacity is deteriorated at high ambient temperature. Select the larger capacity outdoor unit
than compatible building heat load.
4. The appropriate amount (100%) of refrigerant must be charged. Excessive charging of refrigerant is
forbidden.
5. It must be avoided to install the units where affected by direct sunlight reflection and short circuit. There may
be the possibility to activate protection control and alarm system if install the units to inappropriate place.
Also the life time of the products and parts must be considerably shortened.
6. Periodic maintenance (1/certain month) must be applied to the heat exchanger fin to avoid adhesion of dirt
and clogging of sand to the outdoor unit heat exchanger.
7. Refer to the technical catalog for the detail.

* In case cooling operation or simultaneous operation under the inlet air temperature -5°C or lower the conditions
below must be considered at the time of installation.
● Make sure to apply Snow Protection Hood (Optional Parts).
● The minimum capacity of connectable indoor unit is 2.5HP.
● Set the function “Cooling Operation under Low Load Operation” (DSW6) from the outdoor unit
(If multiple outdoor units are connected in a system, set the function only for outdoor unit A).
● Make sure to apply new CH-Box (Optional Parts). The “Low Ambient Setting” is not available if the system is
connected with current CH unit.

This manual should be considered as a permanent part of the air conditioning equipment and should
remain with the air conditioning equipment.

ii FAN-2207 201709

FAN-2209 201709 2-5


OUTDOOR UNIT

CHECKING PRODUCT RECEIVED

l Upon receiving this product, inspect it for any shipping damage.


Claims for damage, either apparent or concealed, should be filed immediately with the shipping
company.
l Check the model number, electrical characteristics (power supply, voltage and frequency) and
accessories to determine if they are correct.

The standard utilization of the unit shall be explained in these instructions.


Therefore, the utilization of the unit other than those indicated in these instructions is not recommended.
Please contact your local agent, as the occasion arises.
YORK’s liability shall not cover defects arising from the alteration performed by a customer without YORK’s
consent in a written form.

FAN-2207 201709 iii

2-6 FAN-2209 201709


OUTDOOR UNIT

TABLE OF CONTENTS

1. Safety Summary ................................................................................................................................................... 1


2. Structure ............................................................................................................................................................... 6
2.1 Outdoor Unit & Refrigerant Cycle ................................................................................................................. 6
2.2 Necessary Tools and Instrument List for Installation .................................................................................... 6
3. Before Installation ................................................................................................................................................. 8
3.1 Line-Up of Outdoor Unit ............................................................................................................................... 8
3.1.1 CH-Box ..............................................................................................................................................11
3.2 Combination of Indoor Unit and Outdoor Unit ............................................................................................ 12
4. Transportation and Handling ............................................................................................................................... 14
4.1 Transportation ............................................................................................................................................ 14
4.2 Handling of Outdoor Unit ............................................................................................................................ 17
5. Outdoor Unit Installation ..................................................................................................................................... 18
5.1 Factory-Supplied Accessories .................................................................................................................... 18
5.2 Installation .................................................................................................................................................. 19
5.3 Service Space ............................................................................................................................................ 20
5.4 Foundation ................................................................................................................................................. 23
5.5 Drain Water Treatment ............................................................................................................................... 25
6. Refrigerant Piping Work ...................................................................................................................................... 27
6.1 Piping Materials .......................................................................................................................................... 28
6.2 Flaring and Joint ......................................................................................................................................... 32
6.3 Caution about Outdoor Unit Installation ..................................................................................................... 33
6.4 Piping Work between Outdoor Units .......................................................................................................... 34
6.5 Piping Connection ...................................................................................................................................... 36
6.5.1 Piping Size between Outdoor Units (Base Unit) ............................................................................... 38
6.5.2 Piping Size between Outdoor Units (2 Units Combination) .............................................................. 39
6.5.3 Piping Size between Outdoor Units (3 Units Combination) .............................................................. 40
6.5.4 Stop Valve......................................................................................................................................... 41
6.5.5 Piping Connection............................................................................................................................. 43
7. Electrical Wiring .................................................................................................................................................. 54
7.1 General Check ........................................................................................................................................... 55
7.2 Electrical Wiring Connection ...................................................................................................................... 55
7.3 Electrical Wiring for Outdoor Unit ............................................................................................................... 60
7.4 Electrical Wiring Connection of Indoor Unit, Outdoor Unit ......................................................................... 63
7.5 Accessing Switches on Printed Circuit Board ............................................................................................ 65
7.6 Dip Switch Setting of Outdoor Unit ............................................................................................................. 66
8. Additional Refrigerant Charge............................................................................................................................. 70
8.1 Air-Tight Test .............................................................................................................................................. 70
8.2 Vacuuming .................................................................................................................................................. 72
8.3 Additional Refrigerant Charge Calculation ................................................................................................. 73
8.4 Charging Work ........................................................................................................................................... 75
9. Test Run .............................................................................................................................................................. 79
9.1 Before Test Run .......................................................................................................................................... 79
9.2 Test Run ..................................................................................................................................................... 81
10. Safety and Control Device Setting ...................................................................................................................... 87

iv FAN-2207 201709

FAN-2209 201709 2-7


OUTDOOR UNIT

1. Safety Summary

< Signal Words >


l Signal words are used to identify levels of hazard seriousness.
Definitions for identifying hazard levels are provided below with their respective signal words.

DANGER : DANGER indicates a hazardous situation which, if not avoided,


will result in death or serious injury.

WARNING : WARNING indicates a hazardous situation which, if not avoided,


could result in death or serious injury.

CAUTION : CAUTION, used with the safety alert symbol, indicates a hazardous situation which,
if not avoided, could result in minor or moderate injury.

NOTICE : NOTICE is used to address practices not related to personal injury.

NOTE : NOTE is useful information for operation and/or maintenance.

FAN-2207 201709 1

2-8 FAN-2209 201709


OUTDOOR UNIT

DANGER
l Do not perform installation work, refrigerant piping work, drain pump, drain piping and electrical wiring
connection without referring to our installation manual. If the instructions are not followed, it may result in
a water leakage, electric shock or a fire.
l Provide a sufficiently strong foundation. If not, the unit may fall down and it may lead to injuries.
l Be sure to use Nitrogen Gas for air-tight test. If other gases such as oxygen gas, acetylene gas or
fluorocarbon gas are accidentally used, it may cause explosion or gas intoxication.
l Do not install the outdoor unit where there is high level of oil mist, flammable gases, salty air or harmful
gases such as sulfur.
l Do not install the outdoor unit to a space where the flammable gases may occur or leak. It may cause fire.
l If the indoor unit is installed in a small room and the refrigerant gas leakage occurs, the leaked refrigerant
gas fills the room and it may cause suffocation. Do not exceed the maximum permissible concentration of
the refrigerant gas in the room. Consult with distributor for countermeasure such a ventilation system, etc.
l Make sure that the refrigerant leakage test should be performed.
Refrigerant (Fluorocarbon) for this unit is incombustible, non-toxic and odorless.
However if the refrigerant is leaked and is contacted with fire, toxic gas will generate.
Also because the fluorocarbon is heavier than air, the floor surface will be filled with it, which could cause
suffocation.
l Use the specified non-flammable refrigerant (R410A) to the outdoor unit in the refrigerant cycle.
Do not charge material other than R410A into the unit such as hydrocarbon refrigerants (propane or etc.),
oxygen, flammable gases (acetylene or etc.) or poisonous gases when installing, maintaining and moving.
These flammables are extremely dangerous and may cause an explosion, a fire, and injury.
l The installer and system specialist shall secure safety against refrigerant leakage according to local
regulations or standards.
l Refrigerant leakage can cause difficulty with breathing due to insufficient air. Turn OFF the main switch,
extinguish any naked flames and contact your service contractor, if refrigerant leakage occurs.
l For installation, firmly connect the refrigerant pipe before the compressor starts operating.
For maintenance, relocation and disposal, remove the refrigerant pipe after the compressor stops.
If the compressor is operated under the condition that the stop valves are opened without refrigerant pipe,
it may cause abnormal high pressure in refrigerant cycle and may cause explosion, fire or injury.
l Remove gas inside the closing pipe when the brazing work is performed.
If the brazing filler metal is melted with remaining gas inside, the pipes will be blown off and it may cause
injury.
l Do not expose surrounding parts and the oil return pipe of the compressor to the fire when a burner is
used. If the oil return pipe is exposed to the fire, high temperature oil will spurt and it will cause a fire or
injury.
l Do not pour water into the indoor or outdoor unit. These products are equipped with electrical parts.
If poured, it will cause a serious electrical shock.
l Do not touch or adjust safety devices inside the indoor unit or outdoor units. If these devices are touched
or readjusted, it may cause a serious accident.
l Do not perform a short-circuit of the protection device such as a pressure switch when operating.
It may cause a fire and explosion.
l The electrical wiring work must be performed by authorized installers. If not performing the electrical work
completely or a capacity shortage of the power circuit, it may cause an electric shock or fire.
l Perform electrical work according to Installation Manual and all the relevant regulation and standards.
If the instructions are not followed, an electrical shock and fire may occur due to insufficient capacity and
inadequate performance.
l Use specified cables between units and choose the cables correctly. If not, an electrical shock or fire may
occur.
l Ensure that the wiring terminals are tightened securely with the specified torques. If not, generating fire or
electrical shock at the terminal connection part may occur.
2 FAN-2207 201709

FAN-2209 201709 2-9


OUTDOOR UNIT

DANGER
l Clamp wires adequately by the cord clamp after the wiring is connected to the terminal block. In addition,
run securely wires through the wiring hole. If not completed, it may cause fire by biting wires.
l Fix the cables securely. External forces on the terminals could lead to a fire.
l Turn OFF the power source completely when handling the service connector.
It may cause an electric shock.
l Do not open the service cover or access panel for the indoor or outdoor units without turning OFF the main
power supply.
l An electrical shock will occur by residual voltage.
Disconnect the power source completely before starting the maintenance for electrical parts.
Check to ensure that no residual voltage is existed after disconnecting the power source.
l In some cases, the packaged air conditioner may not be operated normally under the following cases.
* In case that electrical power for the packaged air conditioner is supplied from the same power
transformer as the device*.
* In case that the power source wires for the device* and the packaged air conditioner are located close to
each other.
Device*: (Ex) Lift, container crane, rectifier for electric railway, inverter power device, arc furnace,
electric furnace, large-sized induction motor and large-sized switch.
It consumes a large quantity of electrical power.

Regarding the cases mentioned above, surge voltage may be inducted in the power supply wiring for the
packaged air conditioner due to a rapid change in power consumption of the device and an activation of
switch.
Therefore, check the field regulations and standards before performing electrical work in order to protect
the power supply for the packaged air conditioner.
l Check that the ground wire is securely connected. If the unit is not correctly grounded, it lead electric
shock. Do not connect the ground wiring to gas piping, water piping, lighting conductor or ground wiring
for telephone.
l Use an ELB (Earth Leakage Breaker).
In the event of fault, there is danger of an electric shock or a fire if it is not used.

FAN-2207 201709 3

2-10 FAN-2209 201709


OUTDOOR UNIT

WARNING
l Do not install the unit in a place where oil, vapor, organic solvent and corrosive gas (ammonia, sulfur
compound and acid) may be present in quantities.
It may cause refrigerant leakage due to corrosion, electrical shock, deteriorated performance and
breakage.
l Do not use any sprays such as insecticide, lacquer, hair spray or other flammable gases within
approximately one (1) meter from the system.
l If circuit breaker or fuse is often activated, stop the system and contact your service contractor.
l Connect the fuse of specified capacity.
l Protect the wires, electrical parts, etc. from rats or other small animals.
If not protected, rats may gnaw at unprotected parts and which may lead to a fire.
l Before performing any brazing work, check to ensure that there is no flammable material around.
l Do not apply excessive force to the flare nut when tightening. If applied, the flare nut may crack due to
aged degradation and refrigerant leakage may occur. Use the specified tightening torque.

CAUTION
l Do not put any foreign material on the unit or inside the unit.
l Do not step or put any material on the product.
It may cause injury by falling down.
l Provide a strong and correct foundation so that;
a. The outdoor unit is not on an incline.
b. Abnormal sound dose not occur.
c. The outdoor unit will not fall down due to a strong wind or earthquake.
l When using refrigerant be sure to wear leather gloves to prevent cold injuries.
l Do not handle the unit by one person. Do not use the PP band to transport the unit although the unit is
packed by PP band. Additionally, do not handle by bare hands. The fin of heat exchanger may cause
injuries.

4 FAN-2207 201709

FAN-2209 201709 2-11


OUTDOOR UNIT

NOTICE
l Do not install the indoor unit, outdoor unit, wired controller and cable within approximately 3 meters from
strong electromagnetic wave radiators such as medical equipment.
l Supply electrical power to the system to energize the oil heater for 12 hours before startup after a long
shutdown.
l Make sure that the outdoor unit is not covered with snow or ice, before operation.
l The piping connection kit may be damaged if its slope exceeds +15o.
l Do not apply an excessive force to the spindle valve at the end of opening. Otherwise, the spindle valve
flies out by refrigerant pressure. At the test run, fully open the gas and liquid valves, otherwise, the
devices will be damaged. (It is closed before shipment.)
l In the case that the pipes are pulled out from the piping cover, after the insulation work is completed, cover
the gap between the piping cover and pipes by a packing (field-supplied). If the gap is not covered, the
unit may be damaged if snow, rain water or small animals enter the unit.
l Check to ensure that each wire is correctly connected at the power source. If it is incorrectly connected,
the unit will not be operated and the alarm code is indicated. In this case, connect the wires correctly.

NOTE
l It is recommended that the room will be ventilated every 3 to 4 hours.
l The heating capacity of the heat recovery unit is decreased according to the outdoor air temperature.
Therefore, it is recommended that auxiliary heating equipment be used in the field when the units is
installed in a low temperature region.

FAN-2207 201709 5

2-12 FAN-2209 201709


OUTDOOR UNIT

2. Structure
2.1 Outdoor Unit & Refrigerant Cycle
Regarding structure drawings and refrigerant cycle diagram, please refer to Technical Catalogue.

2.2 Necessary Tools and Instrument List for Installation

No. Tool No. Tool No. Tool


1 Handsaw 8 Plier 16 Cutter for Wires
2 Phillips Screwdriver 9 Pipe Cutter 17 Gas Leak Detector
3 Vacuum Pump 10 Brazing Kit 18 Leveller
4 Refrigerant Gas Hose 11 Hexagon Wrench 19 Clamper for Solderless Terminals
5 Megohmmeter 12 Spanner 20 Hoist (for Indoor Unit)
6 Copper Pipe Bender 13 Weigher 21 Ammeter
Manual Water Pump 14 Charging Cylinder 22 Voltage Meter
7
(for Indoor Unit) 15 Gauge Manifold 23 Wrench

Use tools and measuring instruments only for the new refrigerant R410A which is directly touch to refrigerant.

Check the design pressure for this product is 4.15MPa.


The pressure of the refrigerant R410A is 1.4 times higher than that of the refrigerant R22. Therefore,
the refrigerant piping for R410A shall be thicker than that for R22. Make sure to use the specified
refrigerant piping. If not, the refrigerant piping may rupture due to an excessive refrigerant pressure.
Besides, pay attention to the piping thickness when using copper refrigerant piping. The thickness
of copper refrigerant piping differs depending on its material.

NOTICE
l The refrigerant R410A is adopted. The refrigerant oil tends to be affected by foreign matters such as
moisture, oxide film, or fat. Perform the installation work with care to prevent moisture, dust or different
refrigerant from entering the refrigerant cycle. Otherwise foreign materials may get mixed into the cycle
from such parts as expansion valve and the operation may be unavailable.
l To the different refrigerant or refrigerant oil from being mixed into the cycle, the sizes of the charging
connections have been changed from R407C type and R22 type.
It is necessary to prepare the following tools before performing the installation work.
l Use refrigerant pipes and joints which can be used for R410A.

6 FAN-2207 201709

FAN-2209 201709 2-13


OUTDOOR UNIT

G: Interchangeability is available with current R22 l: only for Refrigerant R410A (No Interchangeability with R22)
5: Prohibited F: only for Refrigerant R407C (No Interchangeability with R22)
Interchangeability
with R22 Reason of Non-Interchangeability and Attention
Measuring Instrument and Tool Use
(H: Strictly Required)
R410A R407C
Pipe Cutter Cutting Pipe
Chamfering G G - Removing Burrs
Reamer
Flaring Tool Gl G * The flaring tools for R407C are applicable to R22. Flaring for Tubes
* If using flaring tube, make dimension of tube larger Dimensional Control
Extrusion for R410A.
l - for Extruded Portion
Adjustment Gauge * In case of material 1/2H, flaring is not available. of Tube after Flaring
* In case of material 1/2H, bending is not available. Bending
Pipe Bender G G
Use elbow for bend and braze.
* In case of material 1/2H, expanding of tube is not Expanding Tubes
Refrigerant Expanding Tool G G
available. Use socket for connecting tube.
Pipe
l G * For f12.7, f15.88, spanner size is up 2mm. Connection of
Torque Wrench * For f6.35, f9.52, f19.05, spanner size is the Flare Nut
G G
same.
Brazing Tool G G * Perform correct brazing work. Brazing for Tubes
* Strict Control against Contamin Prevention from
Nitrogen Gas G G (Blow nitrogen during brazing.) Oxidation during
Brazing
* Use a synthetic oil which is equivalent to the oil Applying Oil to
Lubrication Oil
l F used in the refrigeration cycle. the Flared Surface
(for Flare Surface)
* Synthetic oil absorbs moisture quickly.
* Check refrigerant cylinder color. Refrigerant Charging
Refrigerant
l F H Liquid refrigerant charging is required regarding
Cylinder
zeotoropic refrigerant.
Vacuum Pump G G H The current ones are applicable. However, it is Vacuum Pumping
S required to mount a vacuum pump adapter which
Adapter for l can prevent from reverse flow when a vacuum
F
Vacuum Pump pump stops, resulting in no reverse oil flow.
* No interchangeability is available due to higher Vacuum Pumping,
Vacuum Manifold Valve l F pressures when compared with R22. Vacuum Holding,
Drying H Do not use current ones to the different refrigerant. Refrigerant Charging
l If used, mineral oil will flow into the cycle and and Check of
Refrigerant cause sludges, resulting in clogging or compressor Pressures
Charge failure.
Charging Hose l F Connection diameter is different; R410A: UNF1/2,
R407C: UNF7/16.
Charging Cylinder 5 5 * Use the weight scale. -
Measuring
Weight Scale G G - Instrument for
Refrigerant Charging
Refrigerant Gas S * The current gas leakage detector (R22) is not Gas Leakage Check
l F
Leakage Detector applicable due to different detecting method.
S: Interchangeability with R407C.

FAN-2207 201709 7

2-14 FAN-2209 201709


OUTDOOR UNIT

3. Before Installation

3.1 Line-Up of Outdoor Unit


(1) This outdoor unit series can build the capacity of 8 to 54HP by combining the outdoor units of 8 to
24HP.
(2) The outdoor unit of 26 to 54HP consists of the combination of 2 to 3 base units.
The combinations not indicated in the table below are unavailable.
(3) Refer to the item 6.3 for caution about outdoor unit installation.

J T O R 080 V P E R B S 1
Version
Factory
S: Shimizu, Japan
Generation
Power Supply
U: 3~, 460V/60Hz
F: 3~/N, 380V/60Hz
R: 3~, 220V/60Hz
Refrigerant
E: R410A
Module and Combination
A: All Inverter Combination
P: All Inverter Module
Air Discharge
V: Vertical
Capacity
HP x 10 (Example: 080 = 8HP)
Application
R: Heat Recovery
Heat Source
O: Air Source
Market Position
T: Tier-1 Commercial VRF
Brand
J: York Brand

8 FAN-2207 201709

FAN-2209 201709 2-15


OUTDOOR UNIT

■ for 3~, 460V/60Hz


< Base Unit >
HP 8 10 12 14 16
Model JTOR080VPEUBS1 JTOR100VPEUBS1 JTOR120VPEUBS1 JTOR140VPEUBS1 JTOR160VPEUBS1

HP 18 20 22 24
Model JTOR180VPEUBS1 JTOR200VPEUBS1 JTOR220VPEUBS1 JTOR240VPEUBS1
< Combination of Base Units > T
HP 26 28 30 32 34
Model JTOR260VAEUBS1 JTOR280VAEUBS1 JTOR300VAEUBS1 JTOR320VAEUBS1 JTOR340VAEUBS1
JTOR120VPEUBS1 JTOR120VPEUBS1 JTOR120VPEUBS1 JTOR140VPEUBS1 JTOR160VPEUBS1
Combination
JTOR140VPEUBS1 JTOR160VPEUBS1 JTOR180VPEUBS1 JTOR180VPEUBS1 JTOR180VPEUBS1

HP 36 38 40 42 44
Model JTOR360VAEUBS1 JTOR380VAEUBS1 JTOR400VAEUBS1 JTOR420VAEUBS1 JTOR440VAEUBS1
JTOR180VPEUBS1 JTOR140VPEUBS1 JTOR180VPEUBS1 JTOR180VPEUBS1 JTOR220VPEUBS1
Combination
JTOR180VPEUBS1 JTOR240VPEUBS1 JTOR220VPEUBS1 JTOR240VPEUBS1 JTOR220VPEUBS1

HP 46 48 50 52 54
Model JTOR460VAEUBS1 JTOR480VAEUBS1 JTOR500VAEUBS1 JTOR520VAEUBS1 JTOR540VAEUBS1
JTOR220VPEUBS1 JTOR240VPEUBS1 JTOR140VPEUBS1 JTOR160VPEUBS1 JTOR180VPEUBS1
Combination JTOR240VPEUBS1 JTOR240VPEUBS1 JTOR180VPEUBS1 JTOR180VPEUBS1 JTOR180VPEUBS1
- - JTOR180VPEUBS1 JTOR180VPEUBS1 JTOR180VPEUBS1

■ for 3~/N, 380V/60Hz


< Base Unit >
HP 8 10 12 14 16
Model JTOR080VPEFBS1 JTOR100VPEFBS1 JTOR120VPEFBS1 JTOR140VPEFBS1 JTOR160VPEFBS1

HP 18 20 22 24
Model JTOR180VPEFBS1 JTOR200VPEFBS1 JTOR220VPEFBS1 JTOR240VPEFBS1
< Combination of Base Units > T
HP 26 28 30 32 34
Model JTOR260VAEFBS1 JTOR280VAEFBS1 JTOR300VAEFBS1 JTOR320VAEFBS1 JTOR340VAEFBS1
JTOR120VPEFBS1 JTOR120VPEFBS1 JTOR120VPEFBS1 JTOR140VPEFBS1 JTOR160VPEFBS1
Combination
JTOR140VPEFBS1 JTOR160VPEFBS1 JTOR180VPEFBS1 JTOR180VPEFBS1 JTOR180VPEFBS1

HP 36 38 40 42 44
Model JTOR360VAEFBS1 JTOR380VAEFBS1 JTOR400VAEFBS1 JTOR420VAEFBS1 JTOR440VAEFBS1
JTOR180VPEFBS1 JTOR140VPEFBS1 JTOR180VPEFBS1 JTOR180VPEFBS1 JTOR220VPEFBS1
Combination
JTOR180VPEFBS1 JTOR240VPEFBS1 JTOR220VPEFBS1 JTOR240VPEFBS1 JTOR220VPEFBS1

HP 46 48 50 52 54
Model JTOR460VAEFBS1 JTOR480VAEFBS1 JTOR500VAEFBS1 JTOR520VAEFBS1 JTOR540VAEFBS1
JTOR220VPEFBS1 JTOR240VPEFBS1 JTOR140VPEFBS1 JTOR160VPEFBS1 JTOR180VPEFBS1
Combination JTOR240VPEFBS1 JTOR240VPEFBS1 JTOR180VPEFBS1 JTOR180VPEFBS1 JTOR180VPEFBS1
- - JTOR180VPEFBS1 JTOR180VPEFBS1 JTOR180VPEFBS1

FAN-2207 201709 9

2-16 FAN-2209 201709


OUTDOOR UNIT

■ for 3~, 220V/60Hz


< Base Unit >
HP 8 10 12 14 16
Model JTOR080VPERBS1 JTOR100VPERBS1 JTOR120VPERBS1 JTOR140VPERBS1 JTOR160VPERBS1

HP 18 20 22 24
Model JTOR180VPERBS1 JTOR200VPERBS1 JTOR220VPERBS1 JTOR240VPERBS1
< Combination of Base Units > T
HP 26 28 30 32 34
Model JTOR260VAERBS1 JTOR280VAERBS1 JTOR300VAERBS1 JTOR320VAERBS1 JTOR340VAERBS1
JTOR120VPERBS1 JTOR120VPERBS1 JTOR120VPERBS1 JTOR140VPERBS1 JTOR160VPERBS1
Combination
JTOR140VPERBS1 JTOR160VPERBS1 JTOR180VPERBS1 JTOR180VPERBS1 JTOR180VPERBS1

HP 36 38 40 42 44
Model JTOR360VAERBS1 JTOR380VAERBS1 JTOR400VAERBS1 JTOR420VAERBS1 JTOR440VAERBS1
JTOR180VPERBS1 JTOR140VPERBS1 JTOR180VPERBS1 JTOR180VPERBS1 JTOR220VPERBS1
Combination
JTOR180VPERBS1 JTOR240VPERBS1 JTOR220VPERBS1 JTOR240VPERBS1 JTOR220VPERBS1

HP 46 48 50 52 54
Model JTOR460VAERBS1 JTOR480VAERBS1 JTOR500VAERBS1 JTOR520VAERBS1 JTOR540VAERBS1
JTOR220VPERBS1 JTOR240VPERBS1 JTOR140VPERBS1 JTOR160VPERBS1 JTOR180VPERBS1
Combination JTOR240VPERBS1 JTOR240VPERBS1 JTOR180VPERBS1 JTOR180VPERBS1 JTOR180VPERBS1
- - JTOR180VPERBS1 JTOR180VPERBS1 JTOR180VPERBS1

T: The outdoor unit from 26 to 54HP consists of the combination of 2 to 3 base units.
The combinations other than listed in above table is prohibited.
NOTE:
Refer to the “Caution about Outdoor Unit Installation”.

10 FAN-2207 201709

FAN-2209 201709 2-17


OUTDOOR UNIT

3.1.1 CH-Box
<CH-Box>
<Single>
J CH - AP 160 SSX

Applicable System
SSX: for Heat Recovery System (3 Pipes System)
Maximum Connectable Indoor Unit Capacity (HP)
160: 6.0HP
280: 6.1HP - 10.0HP
Refrigerant Type
AP: R410A
Unit Type
CH: Cooling/Heating Change-Over Box
Brand
York Brand
Connectable Indoor Unit Number of Connectable
Model Branch
Total Capacity Indoor Unit(*1)
JCH-AP160SSX 1 6.0HP or less (Max. 16kW) 1-7
JCH-AP280SSX 1 6.1HP - 10.0HP (Max. 28kW) 1-8
( 1)
* When multiple indoor units are connected to the same CH-Box, they are controlled within
the same operation mode.

<Multiple>
J CH - AP 16 M SSX
Applicable System
SSX: for Heat Recovery System (3 Pipes System)
Multiple
Branch
04: 4 Branch
08: 8 Branch
12: 12 Branch
16: 16 Branch
Refrigerant Type
AP: R410A
Unit Type
CH: Cooling/Heating Change-Over Box
Brand
York Brand
Connectable Indoor Unit Number of Connectable
Model Branch
Total Capacity Indoor Unit per Branch(*2)
JCH-AP04MSSX 4 16.0HP or less (Max. 44.8kW) 1-6
JCH-AP08MSSX 8 30.0HP or less (Max. 85kW) 1-6
JCH-AP12MSSX 12 30.0HP or less (Max. 85kW) 1-6
JCH-AP16MSSX 16 30.0HP or less (Max. 85kW) 1-6
( 2)
* The indoor units connected to the same branch of the CH-Box are controlled within the
same operation mode.

FAN-2207 201709 11

2-18 FAN-2209 201709


OUTDOOR UNIT

3.2 Combination of Indoor Unit and Outdoor Unit


The following indoor units can be combined with the outdoor unit.

Table 3.1 Indoor Unit Type List


Nominal Capacity (HP)
Indoor Unit Type
0.6 0.8 1.0 1.3 1.5 1.8 2.0 2.3 2.5 3.0 3.3 4.0 5.0 6.0 8.0 10.0
In-the-Ceiling
4-Way Cassette
4-Way Cassette
Compact
2-Way Cassette
Wall
Floor Concealed
Ceiling
: Available

• The number of indoor units connectable to outdoor unit is as follows.


Comply with the following conditions when installing the unit.
• A maximum total capacity of 130% and a minimum total capacity of 50% against the nominal outdoor unit
capacity can be obtained by combination of the indoor units.

Table 3.2 System Combination


Min. Capacity Recommended Range of Total Length between
Outdoor Unit Max. Number of
at Individual Number of Combination Each I.U. and
(HP) Connectable I.U.
Operation Connectable I.U. Capacity Expansion Valve Kit (*)
8 13 8
40m
10 16 10
12 19 10 60m
14 23 16 70m
16 26 16
80m
18 26 16
20 33 18
22 36 20 120m
24 40 26
26 43 26
28 47 32 50 to 130% *1 150m
30 0.6HP *3 50 32 (In case the
32 (1.6kW) 53 32 combination ratio
34 56 32 exceed 130%) *2 180m
36 59 32
38 64 38
40 64 38
42 64 38
44 64 38
46 64 38 200m
48 64 38
50 64 38
52 64 38
54 64 38
*1: There might be the possibility of insufficient capacity of 130% combination ratio if the capacity of combination ratio
of indoor units exceed 100% capacity of outdoor unit. Please refer to the technical catalog.
*2: Contact your distributer or dealer if the capacity of combination ratio exceed 130%.
The system configuration exceed standard combination ratio (130%) without consultation with distributer or dealer is
not acceptable. It may cause activation of alarm and operation failure.
*3: In case of setting low ambient temperature at cooling operation, the minimum capacity of connectable indoor unit
should be 2.5 HP.

12 FAN-2207 201709

FAN-2209 201709 2-19


OUTDOOR UNIT

NOTES:
1. The connectable indoor unit capacity ratio can be calculated as follows.
Connectable Indoor Unit Capacity Ratio = Total Indoor Unit Capacity / Total Outdoor Unit Capacity
2. For the system under which all the indoor units are supposed to operate simultaneously, the total indoor unit capacity
should be less than outdoor unit capacity. Otherwise, it may cause a decrease of operating performance and operating
limit in overload operation.
3. For the system under which all the indoor units are not supposed to operate simultaneously, the total indoor unit
capacity is available up to 130% against the outdoor unit capacity.
4. Maximum number of connectable indoor units differs depending on the model, capacity, environment and installation
place of connected indoor units. Refer to “Technical Catalog” for the selection.
5. When operating the outdoor unit in cold areas with temperatures of -10oC, or under the high heating load conditions,
the total indoor unit capacity should be less than 100% against the outdoor unit capacity and the total piping length
should be less than 300m.
6. The air flow volume for indoor units of 0.6 to 1.0HP is set higher than that for indoor units of 1.5HP or more. Make sure
to select appropriate indoor units when installing indoor units where cold draft may occur during heating operation. If
installing indoor units in such places, refer to the recommended number of connectable indoor units.
7. (*): For connecting Wall Type with the Expansion Valve Kit, the number of connectable indoor unit is limited according
to the total piping length between the expansion valve and the indoor unit. The total piping length must be less than
the length indicated in the table.

The load capacity per hour or the possibility of all indoor units simultaneous operation is unknown at the design stage,
the total capacity of combined indoor units should be not over 100% against the outdoor unit capacity.

FAN-2207 201709 13

2-20 FAN-2209 201709


OUTDOOR UNIT

4. Transportation and Handling


4.1 Transportation
Transport the product as close to the installation location as practical before unpacking.
When using a crane, hang the unit according to the description of the label attached to the outdoor unit.

l Do not hang the unit with the sling belts at the wooden base.

Sling Belt Position

CORRECT INCORRECT
Sling Belt
Sling Belt

Long Hole
Apply sling belts
through long holes
Wooden Base
Wooden Base

l The unit shall not be handled by one person. Do not use the PP band to move the unit although
the unit is packed by PP band. Additionally, do not touch the heat exchanger with bare hands.
The fin of heat exchanger may cause injuries.
l Transportation and Storage
The corrugated paper frame is not sufficiently strong. Therefore follow the instructions below in
order to prevent the unit deformation.
* Do not step or put any material on the product. It may cause injury.
* Apply two sling belts onto the outdoor unit, when lifting it with a crane.
l Transportation and Wire Rope
Plastic Bands
* To protect the unit, do not remove any
Corrugated
packing. Paper Frame
* Do not stack or put any material on Attach four 15mm thick
the product. corrugated corner pads
Do not remove
* Apply wire ropes on both sides of the corrugated paper
as shown.
unit as shown in the figure. frame and plastic
bands.

Banding Wire
Wooden Base

14 FAN-2207 201709

FAN-2209 201709 2-21


OUTDOOR UNIT

Take special care when hanging or moving the outdoor unit because its center of mass is eccentric as shown
in the figure below.

• Center of Gravity

Center of Gravity

a
d

e f c
b
Front Side of Unit

(mm)
460V/60Hz
Outdoor Unit 220V/60Hz
380V/60Hz
(HP)
a b c d e f a b c d e f
8
10 1800 1030 810 700 590 370 1800 1030 810 680 600 370
12
14 1800 1290 810 730 690 370 1800 1290 810 730 690 370
16
1800 1290 810 720 730 340 1800 1290 810 710 730 350
18
20
22 1800 1680 810 710 870 350 1800 1680 810 700 870 350
24

FAN-2207 201709 15

2-22 FAN-2209 201709


OUTDOOR UNIT

• Hanging Method
(1) Hang the unit under packing condition with 2 sling belts as shown in Fig. 4.1.
(2) Do not use a wire rope.
(3) Ensure a balance of unit.
(4) Check the safety and lift up the unit gently in order not to incline the unit.

Sling Belt

Corrugated Paper Frame Min. 2.0m

Do not remove Angle of sling belt


corrugated paper frame is more than 60o.
and plastic bands.
Apply sling belt on the splints
or corrugated cardboard pads
Do not apply more than 15mm thickness.
any force to surface.
(Both Sides) Wooden Base

Apply sling belt through


the long hole.

(kg)
380V/60Hz 220V/60Hz
HP
8 10 12 14 16 18 20 22 24 8 10 12 14 16 18 20 22 24
Net Weight 195 195 215 271 314 315 355 369 370 190 190 210 266 309 310 350 364 365
Gross Weight 211 211 231 289 332 333 375 389 390 206 206 226 284 327 328 370 384 385

460V/60Hz
HP
8 10 12 14 16 18 20 22 24
Net Weight 200 200 220 276 319 320 360 374 375
Gross Weight 216 216 236 294 337 338 380 394 395

Fig. 4.1 Hanging Work for Transportation

(5) Hang the unit without wooden base with 2 sling belts as shown in Fig. 4.2.

Sling Belt

Corrugated Paper Frame Min. 2.0m


Sling Belt
Position
CORRECT

Sling Belt Angle of sling belt


Do not remove is more than 60o.
Long Hole corrugated paper frame.
Apply sling belt on the splints
or corrugated cardboard pads
Do not apply more than 15mm thickness.
INCORRECT any force to surface.
(Both Sides)
Sling Belt

Long Hole
Apply sling belt through
the long hole.

Fig. 4.2 Hanging Work without Wooden Base

16 FAN-2207 201709

FAN-2209 201709 2-23


OUTDOOR UNIT

When using forklift, do not insert forks into Do not apply excessive force to the square holes
the holes on the unit side. The unit may be with forks or other materials. The bottom of the
damaged. unit may be deformed.
* Do not push the bottom base by a fork.
* Do not use a roller.

The holes on Do not apply an excessive force.


the unit side Forks (Both Sides)

• Wooden Base Removal Method


(1) Remove the hexagon head bolt using the ratchet wrench.
(2) Suspend the unit from the wooden base in its packing with two sling belts.
(3) Ensure safety while hoisting the unit gently to prevent the unit from tipping over as shown in Fig. 4.3.

CORRECT
Ratchet
Wrench
Outdoor Unit

INCORRECT
Outdoor Unit
Wrench

Wooden Base

Wooden Base

Fig. 4.3 Wooden Base Removal Method

NOTE
In case of transportation after unpacking, protect the unit with corrugated paper boards or cloths.

Keep distance more than 50mm


Outdoor Unit between the outdoor unit and
Backrest the backrest.

Mast

Fork
Outdoor unit is Outdoor unit is NOT
Contacted to Backrest Contacted to Backrest

Prevent the outdoor unit from contacting to the backrest of forklift during transportation. If not, the heat
exchanger fin may be broken due to sudden starting or stopping.

4.2 Handling of Outdoor Unit

Do not put any foreign material into the outdoor unit and check to ensure that nothing exists in the
outdoor unit before the installation and test run. Otherwise, a fire or failure, etc. may occur.

FAN-2207 201709 17

2-24 FAN-2209 201709


OUTDOOR UNIT

5. Outdoor Unit Installation


5.1 Factory-Supplied Accessories
Check to ensure that the following accessories are packed with the outdoor unit.

Table 5.1 Factory-Supplied Accessories

Accessory 8HP 10HP 12HP 14HP 16HP 18HP 20HP 22HP 24HP Remarks

Connection for
Refrigerant
- - - - -
Low Pressure
ID22.2 ID22.2 ID25.4 ID25.4
Gas Pipe →OD19.05 →OD25.4 →OD28.58 →OD28.58
Connection for
Accessory Refrigerant
- - - - -
Pipe High / Low
ID22.2 ID22.2 ID22.2 ID22.2
Pressure Gas Pipe →OD15.88 →OD19.05 →OD25.4 →OD25.4

Connection for
Refrigerant - - - - - - -
Liquid Pipe OD9.52 OD12.7
→OD12.7 →OD15.88

Cord For Fixing Power


Clamp Source Wire

Cable For Fixing Power


×2 ×2 ×2 ×2 ×2 ×2 ×2 ×2 ×2
Clamp Source Wire

For Power Source


Wire Outlet
×2 ×2 ×2 ×2 ×2 ×2 ×2 ×2 ×2 f70
(Bottom Base,
Piping Cover)
For Transition
Rubber Wire Outlet
×2 ×2 ×2 ×2 ×2 ×2 ×2 ×2 ×2 f62
Bush (Bottom Base,
Piping Cover)
For Control
Wire Outlet
×2 ×2 ×2 ×2 ×2 ×2 ×2 ×2 ×2 f38
(Bottom Base,
Piping Cover)

for Fixing Cord


Screw ×3 ×3 ×3 ×3 ×3 ×3 ×3 ×3 ×3
Clamp and Spare

Combination For Indication of


Attach to Outdoor
Unit Model Combination Unit
Unit A (Main Unit)
Label Model

Caution Label

Open/Close
For Indication
Indication for ×3 ×3 ×3 ×3 ×3 ×3 ×3 ×3 ×3 with Fixing Band
of “Open”
Stop Valve

NOTE
If any of these accessories is not packed with the unit, please contact your contractor.

18 FAN-2207 201709

FAN-2209 201709 2-25


OUTDOOR UNIT

5.2 Installation

l Provide a sufficiently strong foundation. If not, the unit may fall down and it may lead to injuries.
l Do not install the outdoor unit where the flammable gases may occur or leak. Otherwise, it may
cause a fire.
l If the indoor unit is installed in a small room and the refrigerant gas leakage occurs, the leaked
refrigerant gas fills the room and it may cause suffocation. Do not exceed the maximum
permissible concentration of the refrigerant gas in the room. Consult with distributor for
countermeasure such as ventilation system, etc.

(1) Install the outdoor unit in a well dried, ventilated environment.


(2) Install the outdoor unit where it is in the shade or it will not be exposed to direct sunshine or direct
radiation from high temperature heat source.
(3) Install the outdoor unit where the sound or the discharge air from the outdoor unit does not affect
neighbors or surrounding ventilation. The operating sound at the rear or right/left sides is 3 to 6dB(A)
higher than the sound at the front side indicated in the technical catalog.
(4) Install the outdoor unit in a space with limited access to general public.
(5) Check to ensure that the foundation is flat, level and sufficiently strong.
(Perform the foundation work in order to fix firmly the outdoor unit to avoid inclining, abnormal sound
or falling down due to a strong wind or earthquake.)
(6) Do not install the outdoor unit where dust or other contaminations could block the outdoor heat
exchanger.
(7) When the outdoor unit is installed in snow-covered areas, mount the field-supplied snow protection
hood on the top of outdoor unit and the inlet side of heat exchanger to prevent damage or abnormal
vibration of propeller fan. Additionally, provide a base under the unit.
(8) During heating or defrosting operation, drain water is discharged. Provide adequate drainage around
the foundation. If installing the unit on a roof or a balcony, provide the additional drainage around the
foundation to prevent water dripping on a person or forming ice in winter.
(9) Do not install the outdoor unit where a seasonal wind directly blows to the outdoor heat exchanger or
where strong winds through the tall buildings directly blows to the outdoor fan.

NOTES:
1. Do not install the outdoor unit where there is a high level of oil mist, flammable gases, salty air or harmful
gases such as sulphur and an acid or alkaline environment.
2. Do not install the outdoor unit where the electromagnetic wave is radiated directly to the electrical box.
3. Install the outdoor unit as far from the electromagnetic wave radiator as possible, at least 3 meters away
from it.

Seasonal Seasonal Air Outlet


Wind Wind Hood

Air Inlet
Hood

Snow attaches directly Provide a base which has


to the heat exchanger. approximately twice the height of
forecast snow accumulation.

FAN-2207 201709 19

2-26 FAN-2209 201709


OUTDOOR UNIT

5.3 Service Space


Make the service space when outdoor unit is installed as follows.
If the service spaces for air inlet and outlet are insufficient, it may cause a performance degradation and
some abnormalities due to insufficient air intake.
Additionally, the service space is required for facilitating the maintenance.

(Unit: mm)

1500
Min.
Vent Hole

h2
Front Rear
Side Side

h1
1500

500
765

Min. 500 + h2/2 Min. 300 + h1/2

< Side View >

- In the case of no walls on the front side and the rear side, the service space is required as follows.
* Front Side: Min. 500mm
* Rear Side: Min. 300mm
* Right and Left Sides: Min. 10mm (In the case that the snow protection hood (optional part) or
the air outlet duct (field-supplied) is amounted to the unit, the spaces of
min. 50mm are required.)
- If the wall on the front side is over 1,500mm high, the space of (500 + h2/2) mm for the front side is
required.
- If the wall on the rear side is over 500mm high, the space of (300 + h1/2) mm for the rear side is required.
- When the units are surrounded by walls on more than 2 sides, the space indicated in the figure above is
required.
- For walls on more than 2 sides, secure the service space as shown in the following figures.
- If the space between the unit and an obstacle above the unit is less than 1,500mm or the space above
the unit is closed, set up the duct at the air outlet side in order to prevent short circuit.
- When there are obstacles above the unit, the four (front, rear, right and left) sides of the unit shall be
open in principle.

20 FAN-2207 201709

FAN-2209 201709 2-27


OUTDOOR UNIT

1) Walls on 2 Sides
In case that the units are installed adjacent to tall buildings and there are no walls on 2 sides, the
minimum rear side space must be 300mm.

• Single Installation • Multiple / Serial Installation (Unit: mm)


No limit for No limit for No limit for
side wall height. side wall height. side wall height.

Min. 300 Min. 300 Min. 300


(Rear Side Space) (Rear Side Space) (Rear Side Space)
*1)
Min. 10 Min. 200

Front Side Front Side Front Side Front Side Front Side
Min. 500 + h2/2
Min. 400 Min. 400
<Top View> <Top View>

*1): In the case that the field-supplied snow protection hood or <Top View>
the air outlet duct is adopted, the space of minimum 50mm is required.

“ ”
This indicates the direction of the unit
(Front Side) when installing the units.

2) Walls on 3 Sides
• Single Installation (Unit: mm)

Min. 300 + h1/2

Min. 10*1)

Front Side Min. 500 + h2/2

No limit for side wall height.


<Top View>

• Multiple / Serial Installation

< Installation in the Same Direction> < Rear to Rear Installation >

Min. 300 + h1/2 Min. 500 + h2/2


Front Side
Min.10
*1)
Min.10*1)
(Side
Space)
Front Side
Min. 500 Min. 900

*1) Front *1) Front


Min.20 Min.20 Min. 500 + h2/2 Min.20*1) Min.20*1) Min. 500 + h2/2
Side Side

No limit for side wall height. No limit for side wall height.
<Top View> <Top View>

*1): In the case that the field-supplied snow protection hood or the air outlet duct is adopted, the space of minimum 50mm is required.

FAN-2207 201709 21

2-28 FAN-2209 201709


OUTDOOR UNIT

3) Walls on 4 Sides
• Single Installation
No limit for
side wall height.
Min. 300 + h1/2 (Unit: mm)

Min. 200 Min. 200

▼ No limit for
Min. 800
*2)
Front Side side wall height.
Open
Min. 500 + h2/2
<Top View>

• Multiple / Serial Installation

< Installation in the Same Direction> < Rear to Rear Installation >

Min. 300 + h1/2 Min. 500 + h2/2


Front Side
▼ ▼ ▼
Min. 200 Min. 200 Min. 200 Min. 200
▼ ▼ ▼ (Side Space)
Front Side
Min. 900
No limit for No limit for
side wall height. side wall height. No limit for Min. 1600
side wall height. No limit for
▼ ▼ ▼ side wall height.
Min. 800
*2)
Front Side Min. 800*2)
Open Open ▼ ▼ ▼
*2)
Min. 800 Front Side Min. 800*2)
Min. 200 Min. 200 Open Open
Min. 500 + h2/2
<Top View> Min. 200 Min. 200 Min. 500 + h2/2
<Top View>

*2): Partly open a wall if the unit is surrounded by walls on four sides.

NOTES:
1. Keep the upper side open to prevent mutual interference of inlet and outlet air of each outdoor unit.
2. The figure dimensions indicate sufficient spaces around outdoor units for operation and maintenance at
typical installation conditions as follows. [ Operation Mode: Cooling Operation, Outside Temp.: 35oC ]
In case that the outdoor unit ambient temperature is higher and also the short circuit is likely to occur
compared to the installation condition, find an appropriate dimension by calculating air flow current.
3. For the multiple installation, 1 group shall consist of 6 outdoor units (max.).
Keep 1-meter interval between each unit group.

1 Group (Max. 6 Outdoor Units)


Min. 1m

22 FAN-2207 201709

FAN-2209 201709 2-29


OUTDOOR UNIT

5.4 Foundation
• Concrete Foundations
(1) The height of the foundation should be over 150mm above the ground.
(2) Provide a drainage around the foundation for smooth drainage.

Details of Anchor Bolt Installing (Example) (Unit: mm)

Min. 80 Anchor Bolt (M12) (Field-Supplied)


5 70 Nut (Field-Supplied)
Washer (Field-Supplied)
18
Vibration Proof Mat (Field-Supplied)
The corner of the outdoor unit anchoring foot
must be located on the vibration proof mat.
60

Filling Mortar
Min. 150

Hole for Mortar ( 100 x Depth 150)


18 (729) 18
Foundation
70 (625) 70
Drainage
765
Min. 100

Drainage (Example)
(Width 100 x Depth 20)

* Provide concrete foundation as shown in the figure. * Do not provide concrete foundation
as shown below. The foot of the
outdoor unit may be deformed.

Front Side Front Side Front Side


of Unit of Unit of Unit

Correct Correct Foot


Incorrect
Foundation

Min. 100mm
Foot
Foot
Foundation
Min. 100mm Foundation Min. 100mm
Min. 100mm
Min. 100mm (Center of Outdoor Unit) The concrete foundations are
installed to each corner of
The concrete foundations are The concrete foundations are the outdoor unit.
installed along the outdoor unit installed along the outdoor unit In this case, the foot of the
width direction. depth direction. outdoor unit may be deformed.

(3) Install the outdoor unit in the front-rear and right-left direction horizontally. (Use a level gauge.)
Check to ensure that the gradient in four directions (front, rear, right and left) is within 10mm.

Front Side
Right Side and Rear Side
and Left Side

FAN-2207 201709 23

2-30 FAN-2209 201709


OUTDOOR UNIT

(4) Provide a strong and correct foundation so that;


a. The outdoor unit does not incline.
b. Abnormal sound does not occur.
c. The outdoor unit will not fall down due to a strong wind or earthquake.

(5) When installing the outdoor unit, fix the unit with anchor bolts and vibration proof mat (field-supplied).
Refer to Fig. 5.1 regarding the location of fixing holes.

(Unit: mm)
Outdoor Unit Dimension

(For Anchor Bolt)


Min. 80

(For Anchor Bolt)


Min. 80

8 - 12HP
Hole for M12 Anchor Bolt
(4 - 38 x 15 Long Hole)

Vibration Proof Mat


6 Positions (Front and Rear Side)

(For Anchor Bolt)


Min. 80

(For Anchor Bolt)


Min. 100

14 - 18HP Hole for M12 Anchor Bolt


(4 - 38 x 15 Long Hole)

Vibration Proof Mat


6 Positions (Front and Rear Side)

(For Anchor Bolt) (For Anchor Bolt)


Min. 80
(For Anchor Bolt)

Min. 120

20 - 24HP
Hole for M12 Anchor Bolt
(6 - 38 x 15 Long Hole)

Vibration Proof Mat


6 Positions (Front and Rear Side)

Fig. 5.1 Position of Anchor Bolts

24 FAN-2207 201709

FAN-2209 201709 2-31


OUTDOOR UNIT

5.5 Drain Water Treatment


Drain water is discharged during heating and defrosting operation. (Rain water is also discharged.)
Comply with the following conditions.
(1) Choose a place where good drainage is available, or provide a drain ditch.
(2) Do not install the unit over the walkways. Condensation water may fall on people.
In case of installing the unit in such a place, provide the additional drain pan.
(3) When drain piping is necessary for the outdoor unit, use the drain boss set (Optional, DBS-TP10A).
Do not use drain boss and drain pan kit in the cold area. The drain water in the drain pipe may be
frozen and then the drain pipe may crack.
NOTE:
Even when the drain boss set is used, the water may drain slightly from the screw holes.
Provide a second drain pan under the outdoor unit as necessary.

(Unit: mm)
Outdoor Unit Dimension

Power Source Wiring Outlet


(φ65 Knockout Hole) Hole for Drain (φ26 x 2 Positions)
Transition Wiring Outlet Positions of Drain Boss (Optional)
(φ55 Knockout Hole)
Control Wiring Outlet
(φ33 Knockout Hole)

8 - 12HP

Refrigerant Piping Outlet


for Low Pressure Gas Pipe
(Knockout Square Hole)

Refrigerant Piping Outlet


for High/Low Pressure Gas Pipe and Liquid Pipe
(Knockout Square Hole)

Power Source Wiring Outlet


(φ65 Knockout Hole) Hole for Drain (φ26 x 2 Positions)
Transition Wiring Outlet Positions of Drain Boss (Optional)
(φ55 Knockout Hole)
Control Wiring Outlet
(φ33 Knockout Hole)

14 - 18HP

Hole for Drain (φ26 x 2 Positions)


Positions of Drain Cap (Optional)
Refrigerant Piping Outlet
for High/Low Pressure Refrigerant Piping Outlet
Gas Pipe and Liquid Pipe for Low Pressure Gas Pipe
(Knockout Square Hole) (Knockout Square Hole)

Power Source Wiring Outlet Hole for Drain (φ26 x 2 Positions)


(φ65 Knockout Hole) Positions of Drain Cap (Optional)

Transition Wiring Outlet


(φ55 Knockout Hole)
Control Wiring Outlet
(φ33 Knockout Hole) Hole for Drain (φ26 x 2 Positions)
Positions of Drain Boss (Optional)

20 - 24HP

Refrigerant Piping Outlet Refrigerant Piping Outlet


for High/Low Pressure Gas for Low Pressure Gas Pipe
Pipe and Liquid Pipe (Knockout Square Hole)
(Knockout Square Hole)

FAN-2207 201709 25

2-32 FAN-2209 201709


OUTDOOR UNIT

• Drain Boss (Optional Parts)


The drain boss is for the drain pipe connection in order to use outdoor unit bottom base as a drain pan.

Name Model
Drain Boss DBS-TP10A
Component Formation of Drain Boss
Model Parts Name Material / Color Q'ty Application
Drain Boss PP / Black 2 Connecting for Drain Piping
DBS-TP10A Drain Cap PP / Black 2 Embolization for Drain Hole
Rubber Cap CR / Black 4 Sealing for Boss and Cap

Quantity
Applicable
Q'ty
Outdoor Unit HP
8 - 18 1
20 - 36 2
38, 40 3
42 - 48 4
50 - 54 3

NOTE
1. When installing the unit above a passage way, drain water sometimes turns to ice on a cold morning.
Therefore, avoid discharging the water into places which people often pass through, because it is slippery.
2. When drain piping is necessary for the outdoor unit, use the drain boss set (Optional, DBS-TP10A).
Do not use drain boss and drain pan kit in the cold area. The drain water in the drain pipe may be frozen
and then the drain pipe may crack.

26 FAN-2207 201709

FAN-2209 201709 2-33


OUTDOOR UNIT

6. Refrigerant Piping Work

l Use the specified non-flammable refrigerant R410A to the outdoor unit in the refrigerant cycle.
Do not charge material other than R410A into the unit such as hydrocarbon refrigerants (propane
or etc.), oxygen, flammable gases (acetylene or etc.) or poisonous gases when installing,
maintaining and moving the unit. These flammables are extremely dangerous and may cause an
explosion, fire, and injury.
l Check to ensure that no pressure exists inside the stop valve before removing the flange.
l Make sure that the refrigerant leakage test is performed. The refrigerant (Fluorocarbon R410A)
for this unit is nonflammable, non-toxic and odorless. However, if the refrigerant leaks and
contacts fire, toxic gas will generate. Also because the fluorocarbon is heavier than air, the floor
surface will be filled with it, which could cause suffocation.
l For installation, firmly connect the refrigerant pipe before the compressor starts operating.
For maintenance, relocation and disposal, remove the refrigerant pipe after the compressor
stops.
If the compressor is operated under the condition that the stop valves are opened without
refrigerant pipe, it may cause abnormal high pressure in refrigerant cycle and may cause an
explosion, fire or injury.
l Before performing any brazing work, check to ensure that there is no flammable material around.
If not, it may cause a fire.
l If the indoor unit is installed in a small room and the refrigerant gas leakage occurs, the leaked
refrigerant gas fills the room and it may cause suffocation. Do not exceed the maximum
permissible concentration of the refrigerant gas in the room. Consult with distributor for an
appropriate ventilation system, etc.
l Check the design pressure for this product is 4.15MPa.
The pressure of refrigerant R410A is 1.4 times higher than that of refrigerant R407C. The
thickness of copper pipe differs depending on its materials, so use the specified piping.
If the specified materials are not used, it may cause explosion, injury, leakage, or fire.

l Ensure to connect the piping among the units in the same refrigerant cycle.
l Wear leather gloves when handling the refrigerant.
If the refrigerant splashes directly to hands, it may be the cause of frostbite.
l Do not apply an excessive force to the flare nut when tightening it. Otherwise, the flare nut may
crack due to aged degradation and refrigerant leakage may occur. Use the specified tightening
torque.

NOTICE
l The refrigerant R410A is adopted. The refrigerant R410A and the refrigerant oil tend to be
affected by foreign matters such as moisture, oxide film, or fat. Perform the installation work
with care to prevent moisture, dust or different refrigerant from entering the refrigerant cycle.
Otherwise, foreign materials may get mixed into the cycle from such parts as expansion valve
and the operation may be unavailable.
l Perform the drain piping work in order to drain water securely. If not, the drain water can flow
back to the unit and it may cause leakage to the room.

FAN-2207 201709 27

2-34 FAN-2209 201709


OUTDOOR UNIT

6.1 Piping Materials


(1) Prepare locally-supplied copper pipes.
(2) Use the phosphorus-deoxidized copper pipe for refrigerant piping, which is based on the JIS H3300
“Copper and copper alloy seamless pipes and tubes.”
(3) Select the piping size from the Table 6.1 and Table 6.2.
Pay attention to pipe selection, because the thickness of copper pipe differs depending on its material.
(4) Use clean copper pipes. Make sure there is no dust and moisture inside the pipes. Blow nitrogen or
dry air into the pipes to remove any dust or foreign materials before connecting pipes. Do not use any
tools which produce a lot of swarf such as a saw or a grinder.
(5) Take special care to prevent contaminations and moisture entering the pipe interior during the piping
work.
(6) Avoid performing the piping connection work for outdoor unit in the rain.

• Cautions for Refrigerant Pipe Ends


When installing pipe through Do not place the pipe
the wall, secure a cap at the Correct Incorrect
directly on the ground.
end of the pipe.
Correct Incorrect Correct Incorrect
Rain water
can enter.

Hole Hole

Attach a cap Attach a cap


Attach a cap or vinyl tape. or vinyl bag with
or vinyl tape. rubber band.

• Brazing Work
(1) The brazing work must be performed by a authorized installer in order to prevent any trouble.
(2) For piping connection, perform securely non-oxidation brazing with nitrogen substitution. If brazing
the pipes without the nitrogen substitution, a large amount of oxidized scale will be generated in the
pipes. This oxidized scale may cause clogging in the expansion valve, solenoid valve, accumulator
and compressor, which can prevent the unit from operating properly.
Do not use field-supplied antioxidant, etc., which may corrode pipes and deteriorate the refrigerant oil.
Pressure Reducing Valve
(Stop Valve)

Brazing Part Nitrogen Gas Pressure


< 0.02 MPa

Nitrogen Gas

Pipe Valve
Piping Connection on-site (φ6.35)
NOTE:
Do not cover the outlet. If the inner Cover the gap with
Nitrogen
pressure exceeds atmospheric pressure, taping or a rubber plug
Gas
a pinhole may generate and the refrigerant to prevent air from entering
gas will leak from the brazing part. the pipe interior.

NOTES:
1. Make sure to use nitrogen. Nitrogen gas pressure shall be 0.02 MPa or less.
DO NOT use the following gases.
Oxygen: flammable and causes oxidation degradation of the refrigerant oil.
Carbon Dioxide: may cause decrease in drier performance.
Freon Gas: emits harmful gases if exposed to fire.

2. Make sure to use the pressure reducing valve.


3. Do not use field-supplied antioxidant.

(3) Use a quality brazing filler metal specified in JIS. Select a flux whose chlorine concentration is low.
(4) Remove the flux completely after the brazing work.
NOTE:
When the brazing work is performed, perform brazing to minimum portion by appropriate temperature
to suppress generating oxidized scale.

28 FAN-2207 201709

FAN-2209 201709 2-35


OUTDOOR UNIT

● Cautions for Piping Connection Work


(1) Connect the indoor/outdoor units with refrigerant pipes. Fix the pipes and prevent the pipes from
contacting weak portions such as wall, ceiling, etc. (Otherwise, abnormal sound may be heard due to
vibration of the piping.)
NOTE:
When on-site piping with joint such as elbow or socket is buried, provide a service access door to
facilitate the check for connecting part.
(2) Check that there are no scratch, swarf, deformation, gap, etc. at the flaring part, before the connecting
work.
(3) Apply refrigerant oil slightly on the sheet surface of the pipe and flare nut before the flaring work. And
then tighten the flare nut with the specified tightening torque using two spanners. Perform the flaring
work on the liquid piping side before the gas piping side. Check that no gas leakage occurred after the
flaring work.
NOTE:
Refrigerant oil is field-supplied.
[Ethereal Oil FVC50K, FVC68D (Idemitsu Kousan Co. Ltd.)]

Apply Refrigerant Oil.

Do not apply
the refrigerant oil
to the outside of
the flaring part.

(4) Be sure to use the accessory flare nuts for indoor unit connections.
(5) In case that the temperature and humidity inside the ceiling exceed 27oC/RH80%, apply additional
insulation (approx. 10mm in thickness) to the accessory insulation. It prevents dew condensation on
the surface of the insulation (refrigerant pipe only).
(6) Perform the air-tight test (4.15MPa for the test pressure).
(7) Perform cold insulation work by insulating and taping the flare connection and reducer connection.
Also insulate all the refrigerant pipes.

● When tightening the flare nut, use two spanners.

Required Tightening Torque (JIS B8607)


Do not put two spanners here.
Pipe Size Tightening Torque Refrigerant leakage may occur.
f6.35 (1/4) 14 to 18 (N-m)
f9.52 (3/8) 34 to 42 (N-m)
f12.7 (1/2) 49 to 61 (N-m)
f15.88 (5/8) 68 to 82 (N-m)
f19.05 (3/4) 100 to 120 (N-m)
Two Spanners Work Tightening Work for Stop Valve (Liquid)

FAN-2207 201709 29

2-36 FAN-2209 201709


OUTDOOR UNIT

● When connecting the indoor unit and outdoor unit refrigerant pipes, the refrigerant pipes shall be supported
appropriately. Do not let contact them with the weak strength portion of a wall or a ceiling. If not, it may
cause abnormal sound due to piping vibration.
● Precautions during installing and fixing the pipes.

< Example of Support Direction >

CORRECT

within + 15o

Outdoor Unit

Piping Support Parts Fireproof Compartment


(to support pipes at appropriate intervals) Construction
INCORRECT

Multi-Kit
Indoor Unit
Install multi-kits horizontally.

< Fixing Liquid Piping and Gas Piping >


Piping Supporting Parts
High/Low Pressure Gas Piping

Low Pressure NOTICE:


Gas Piping Temperature changes in refrigerant during operation
of the unit can cause pipes to expand or contract.
If tying the gas piping with liquid piping together by taping,
Liquid Piping it may cause of a piping deformation.

Example: Recommended From each Indoor Unit to Multi-Kit, use hard copper pipes that bend to prevent kinking.

Hard Copper Piping will expand and contract due


to temperature changes in piping. Multi-Kit Connection Pipe
Bending Pipe NOTICE:
When on-site piping is installed using
Outdoor Unit soft or hard copper, make sure that the
Multi-Kit piping is installed to allow for movement
Install Horizontally of the piping. Temperature changes cause
Indoor Unit contraction and expansion of the piping.

NOTE
When on-site piping with joint such as elbow or socket is buried, provide a service access door to
facilitate the check for connecting part.

Do not apply an excessive force to the flare nut when tightening it. Otherwise, the flare nut may
crack due to aged deterioration and refrigerant leakage may occur. Use the specified tightening
torque.

30 FAN-2207 201709

FAN-2209 201709 2-37


OUTDOOR UNIT

Table 6.1 Piping Size of Outdoor Unit


(mm)
Gas
Outdoor Unit HP Liquid
Low Pressure High/Low Pressure
8 f19.05 (f19.05 - f22.2) f15.88 (f15.88 - f19.05) f9.52 (f9.52 - f12.7)
10 f22.2 (f22.2 - f25.4) f19.05 (f19.05 - f22.2) f9.52 (f9.52 - f12.7)
12 and 14 f25.4 (f25.4 - f28.58) f22.2 (f22.2 - f25.4) f12.7 (f12.7 - f15.88)
16 f28.58 (f28.58 - f31.75) f22.2 (f22.2 - f25.4) f12.7 (f12.7 - f15.88)
18 and 20 f28.58 (f28.58 - f31.75) f22.2 (f22.2 - f25.4) f15.88 (f15.88 - f19.05)
22 and 24 f28.58 (f28.58 - f31.75) f25.4 (f25.4 - f28.58) f15.88 (f15.88 - f19.05)
26 f31.75 (f31.75 - f34.9) f25.4 (f25.4 - f28.58) f19.05 (f19.05 - f22.2)
28 - 34 f31.75 (f31.75 - f34.9) f28.58 (f28.58 - f31.75) f19.05 (f19.05 - f22.2)
36 f38.1 (f38.1 - f41.3) f28.58 (f28.58 - f31.75) f19.05 (f19.05 - f22.2)
38 - 54 f38.1 (f38.1 - f41.3) f31.75 (f31.75 - f34.9) f19.05 (f19.05 - f22.2)

Table 6.2 Piping Size of Indoor Unit


(mm)
Indoor Unit HP Gas Liquid
1.5 or less f12.7 f6.35
2.0 f15.88 f6.35
2.5 - 6.0 f15.88 f9.52
8.0 f19.05 f9.52
10.0 f22.2 f9.52

• Piping Thickness and Material (mm)


Use the pipe as below. R410A
Outer Diameter
The thickness of refrigerant pipe differs Thickness Material
depending on design pressure. f6.35 0.8 O material
For copper pipe, pay attention to pipe selection,
f9.52 0.8 O material
because the piping thickness differs depending
f12.7 0.8 O material
on its material.
f15.88 1.0 O material
1.2 O material
f19.05
1.0 1/2H material
Do not use a thin pipe other than f22.2 1.0 1/2H material
shown in the right table.
f25.4 1.0 1/2H material
f28.58 1.0 1/2H material
f31.75 1.1 1/2H material
f38.1 1.35 1/2H material
f44.45 1.55 1/2H material

FAN-2207 201709 31

2-38 FAN-2209 201709


OUTDOOR UNIT

6.2 Flaring and Joint


• Flaring Dimension
Perform the flaring work as shown below.

90o + 2o
(mm)
+0
45 o Diameter A
+ 2o -0.4
(fd)
fA R410A
6.35 9.1
9.52 13.2
0.4 ~ 0.8R
12.7 16.6 (T) It is impossible to perform the flaring
15.88 19.7 work with 1/2H material. In this case,
fd 19.05 (T) use an accessory pipe (with a flare).

• Joint Selection
If 1/2H material is used, the flaring work cannot be performed. In this case, use a joint selected from the
table below.

< Minimum Thickness of Joint (mm) > < Flare Nut Dimension B (mm) >
Diameter R410A Diameter R410A B

f6.35 0.5 f6.35 17


f9.52 0.6 f9.52 22
f12.7 0.7 f12.7 26
f15.88 0.8 f15.88 29
f19.05 0.8 f19.05 36
f22.2 0.9
f25.4 0.95
f28.58 1.0 Flare Nut
f31.75 1.1 NOTE:
f38.1 1.35 Do not use a thin joint other than
f44.5 1.55 the ones shown in the left table.

• Processing at Brazing Connection


To prevent gas leakage at the brazing connection, refer to the table for the insertion depth and the gap for
joint pipe.
(mm)
Diameter Min. Insertion Depth Gap
(D) (B) (A - D)
B
5 <D< 8 6
0.05 - 0.35
8 < D < 12 7
φD φA 12 < D < 16 8
0.05 - 0.45
16 < D < 25 10
25 < D < 35 12
0.05 - 0.55
35 < D < 45 14

32 FAN-2207 201709

FAN-2209 201709 2-39


OUTDOOR UNIT

6.3 Caution about Outdoor Unit Installation


When the installation and piping work for the multiple outdoor units are performed, it is required that the
arrangement for outdoor units and piping length be determined. Perform securely the installation work
according to the following restrictions. If the arrangement for outdoor units is incorrect, it may cause flowback
of the refrigerant and result in failure of outdoor unit.

< Restrictions for 2 and 3 Units Combination >


(1) For 2 and 3 outdoor units combination, align the outdoor units from largest capacity to smallest as A >
B > C and outdoor unit “A” should be connected to the piping connection kit 1.
(2) The piping length between the piping connection kit 1 and the outdoor unit should be
La < Lb < Lc < 10m.
(3) For maintenance, attach “Main unit label” to the service cover (back side surface) of the outdoor unit “A”.

A > B > C C < B < A

Piping Outlet Outdoor Unit Outdoor Unit Outdoor Unit Outdoor Unit Outdoor Unit Outdoor Unit Piping Outlet
Direction A B C C B A Direction

Indoor Unit Indoor Unit


Side Piping Piping Side
Connection Kit 2 Connection Kit 2
Lb Lb
Piping La La Piping
Connection Kit 1 Lc Lc Connection Kit 1

: Keep the straight-line distance of 500mm or more for piping after the piping connection kit.

FAN-2207 201709 33

2-40 FAN-2209 201709


OUTDOOR UNIT

6.4 Piping Work between Outdoor Units


The optional piping connection kit is required for the combination unit.
It is NOT required for the base unit (8 - 24HP).
Applicable Outdoor Unit
Piping
Outdoor Unit Outdoor Unit Model Remarks
Set
HP Number
for Low Pressure Gas: 1
26 - 48 2 MC-NP21SX 1 for High/Low Pressure Gas: 1
for Liquid: 1
for Low Pressure Gas: 2
50 - 54 3 MC-NP30SX 1 for High/Low Pressure Gas: 2
for Liquid: 2
NOTES:
1. The piping connection kit (MC-NP**SX) consists of branch pipes for gas and liquid.
Connecting pipe is not included in these kits (Field-Supplied).
2. The old model (MC-NP**X1) is not available.

Select the pipe size according to the item 6.5.1 - 6.5.3 “Piping Size between Outdoor Units”.
For refrigerant piping work, the optional piping connection kit is required to branch the pipe between outdoor
units.
The arrangement for outdoor units should be determined depending on the piping direction when the
refrigerant piping work and installation work are planned. When the outdoor unit is installed, perform the
installation work according to the following restrictions.
(1) Piping length between piping connection kit 1 and each outdoor unit should be
LA < LB < LC < LD <10m.
Keep the straight-line distance of 500mm or more after the piping connection kit 1.

Upstream Side

Keep the straight-line Max. lift difference


distance of 500mm or between outdoor
Outdoor
Outdoor Outdoor Outdoor more for piping after Outdoor Outdoor units is 100mm.
Unit
Unit Unit Unit the piping connection kit. Unit Unit C
A B C A B

Indoor Unit Side


LA LB LC
Indoor Unit Side
Piping Connection Kit 1 Piping Connection Kit 2

Piping Connection Kit 1 Piping Connection Kit 2

(2) Place the piping connection kit lower than the outdoor unit piping connection.
In case that the piping connection kit is placed higher than the outdoor unit piping connection, keep
300mm (max.) between the piping connection kit and the bottom of the outdoor unit. Also, provide the
oil trap (min. 200mm) between the piping connection kit and the outdoor unit.

Indoor Unit Side

Oil Trap Oil Trap Oil Trap


Min. 200mm Min. 200mm Min. 200mm

Indoor Unit Side

Max. Max.
Max.
Indoor Unit Side 300mm 300mm
300mm
The refrigerant oil is stagnated to the unit stopped.

34 FAN-2207 201709

FAN-2209 201709 2-41


OUTDOOR UNIT

(3) In case that the piping length between outdoor units is 2m or more, the oil trap for the gas pipe should
be provided so that accumulation of refrigerant oil may not occur.

● Less than 2m ● 2m or More

Oil Trap Oil Trap


Min. 200mm Min. 200mm
Indoor Unit Side Indoor Unit Side

Less than 2m Less than 2m Less than 2m Less than 2m


2m or more 2m or more

(4) Place the outdoor unit pipe horizontally or with the pipe slanted downward towards the indoor unit side
so that accumulation of refrigerant oil may not occur in the pipe.

Indoor Unit Side Indoor Unit Side

Refrigerant oil accumulates in the pipe.

(5) For servicing, in case that the pipe is placed frontward of the outdoor unit, secure min. 500mm
between the outdoor unit and piping connection kits. (When the compressor is replaced, a space of
min. 500mm is required.)
Outdoor Unit Outdoor Unit Outdoor Unit

Min. 500mm

Piping Piping
Connection Kit Connection Kit

(6) Direction of Piping Connection Kit


Place the piping connection kit vertically to the ground (the slope must be within +15o) as shown in the
figure.

within + 15o

NOTICE
The refrigerant system may be damaged if the slope of the piping connection kit exceeds +15o.

FAN-2207 201709 35

2-42 FAN-2209 201709


OUTDOOR UNIT

6.5 Piping Connection


Perform the piping connection work for each outdoor unit.
NOTE:
Ensure that the refrigerant pipe should be connected to the same refrigerant cycle unit.

● Prepare the refrigerant pipe in the field for the piping work.
Refer to Fig. 6.1 for the position of piping connection.
(Unit: mm)

I (High/Low Pressure Gas Piping Connection)


H (Low Pressure Gas Piping Connection)
G (Liquid Piping Connection)
Control Wiring Outlet
(φ33 Knockout Hole)
Low Pressure Gas
Piping Connection A
Transition Wiring Outlet
High/Low Pressure Gas (φ55 Knockout Hole)
Piping Connection B
P 65
Liquid Piping Connection C

Piping Cover
N
Square Hole of Piping Cover
(Knockout Hole)
D
E

100
J (Liquid Piping Connection)

253
248
F
K (Low Pressure Gas Piping Connection)

92
L (High/Low Pressure Gas Piping Connection)
Power Source Wiring Outlet M 127
(φ65 Knockout Hole) Low Pressure Gas
High/Low Pressure Gas Piping and Liquid Piping Outlet Piping Outlet
* The figures illustrate the examples of a small cabinet. (Knockout Square Hole) (Knockout Square Hole)

Piping Diameter Dimension (mm)


Outdoor Unit Gas
(HP) Low High/Low Liquid A B C D E F G H I J K L M N P
Pressure Pressure
8 f19.05 f15.88 f9.52
10 f22.2 f19.05 f9.52 f22.2 f22.2 f9.52 269 331 414 268 163 163 117 131 131 240 225 305
12 f25.4 f22.2 f12.7
14 f25.4 f22.2 f12.7
16 f28.58 f22.2 f12.7 f25.4 f22.2 f12.7 178 239 322 263 160 163 112 130 131 147 132 212
18 f28.58 f22.2 f15.88
20 f28.58 f22.2 f15.88
22 f28.58 f25.4 f15.88 f28.58 f22.2 f15.88 177 239 322 259 160 163 132 152 153 147 132 212
24 f28.58 f25.4 f15.88

Fig. 6.1 Refrigerant Piping Connection

36 FAN-2207 201709

FAN-2209 201709 2-43


OUTDOOR UNIT

● Piping Direction
Fix the pipes adequately in order to avoid vibration and excessive
force to the valve.
(1) The pipes can be installed in three directions (front, rear or
bottom side) from the bottom base.
For vibration protection, properly fix the piping connection and
check that no excessive force is applied to the stop valve. Front Side

Bottom Base

Bottom Side Rear Side

(2) Operation of the stop valve should be performed according to Item 6.5.4.
(3) Connect the pipes according to Table 6.1 and 6.2.
(4) Completely seal the penetration part at the bottom of the pipes with insulation in order to prevent rain
water from entering the conduit.

● For Piping from Bottom Base ● For Piping from Front or Rear Side Piping Cover

Control Wiring Liquid Pipe Cover gaps with packings (field-supplied).


Install accessory rubber bushes to the wiring outlets.
Transition Wiring High/Low Pressure Gas Pipe
Power Source Low Pressure Gas Pipe Piping Control Wiring
Wiring Cover
Transition Wiring

Low Pressure
Gas Pipe
Power Source
Cover gaps with packings (field-supplied). Wiring Liquid High/Low Pressure
Install accessory rubber bushes to the wiring outlets. Pipe Gas Pipe

NOTICE
After removing the pipes and completing insulation work, cover the gap between the pipe cover and the
pipes with packing (field-supplied). If the gap is not covered, the unit may be damaged if snow, rain water or
animals enter the unit.

FAN-2207 201709 37

2-44 FAN-2209 201709


OUTDOOR UNIT

6.5.1 Piping Size between Outdoor Units (Base Unit)

Outdoor Unit

a
Refrigerant Piping
To Indoor Units

(fmm)
Outdoor Unit
8 10 12 14 16
(HP)
Low Pressure 19.05 22.2 25.4 25.4 28.58
Gas (19.05 - 22.2) (22.2 - 25.4) (25.4 - 28.58) (25.4 - 28.58) (28.58 - 31.75)
High/Low 15.88 19.05 22.2 22.2 22.2
Piping Size a
Pressure Gas (15.88-19.05) (19.05 - 22.2) (22.2 - 25.4) (22.2 - 25.4) (22.2 - 25.4)
9.52 9.52 12.7 12.7 12.7
Liquid
(9.52 - 12.7) (9.52 - 12.7) (12.7 - 15.88) (12.7 - 15.88) (12.7 - 15.88)

Outdoor Unit
18 20 22 24
(HP)
Low Pressure 28.58 28.58 28.58 28.58
Gas (28.58 - 31.75) (28.58 - 31.75) (28.58 - 31.75) (28.58 - 31.75)
High/Low 22.2 22.2 25.4 25.4
Piping Size a
Pressure Gas (22.2 - 25.4) (22.2 - 25.4) (25.4 - 28.58) (25.4 - 28.58)
15.88 15.88 15.88 15.88
Liquid
(15.88-19.05) (15.88-19.05) (15.88-19.05) (15.88-19.05)
If the specified main refrigerant piping on the table is not available on site, follow the allowable piping size in parentheses.
When using the main refrigerant piping indicated in parentheses, prepare an appropriate reducer on site.

38 FAN-2207 201709

FAN-2209 201709 2-45


OUTDOOR UNIT

6.5.2 Piping Size between Outdoor Units (2 Units Combination)


(Indoor Unit on Left Side) (Indoor Unit on Right Side)

Outdoor Unit A Outdoor Unit B Outdoor Unit B Outdoor Unit A

a b b a
c c

To Indoor Units Piping Connection Kit Piping Connection Kit To Indoor Units

(fmm)
Outdoor Unit
26 28 30 32 34 36
(HP)
Combination Outdoor Unit A 14 16 18 18 18 18
Unit Outdoor Unit B 12 12 12 14 16 18
Piping Connection Kit MC-NP21SX
Low Pressure 31.75 31.75 31.75 31.75 31.75 38.1
Gas (31.75-34.9) (31.75-34.9) (31.75-34.9) (31.75-34.9) (31.75-34.9) (38.1-41.3)
High/Low 25.4 28.58 28.58 28.58 28.58 28.58
a
Pressure Gas (25.4-28.58) (28.58-31.75) (28.58-31.75) (28.58-31.75) (28.58-31.75) (28.58-31.75)
19.05 19.05 19.05 19.05 19.05 19.05
Liquid
(19.05-22.2) (19.05-22.2) (19.05-22.2) (19.05-22.2) (19.05-22.2) (19.05-22.2)
Low Pressure 25.4 28.58 28.58 28.58 28.58 28.58
Gas (25.4-28.58) (28.58-31.75) (28.58-31.75) (28.58-31.75) (28.58-31.75) (28.58-31.75)
High/Low 22.2 22.2 22.2 22.2 22.2 22.2
Piping Size b
Pressure Gas (22.2-25.4) (22.2-25.4) (22.2-25.4) (22.2-25.4) (22.2-25.4) (22.2-25.4)
12.7 12.7 15.88 15.88 15.88 15.88
Liquid
(12.7-15.88) (12.7-15.88) (15.88-19.05) (15.88-19.05) (15.88-19.05) (15.88-19.05)
Low Pressure 25.4 25.4 25.4 25.4 28.58 28.58
Gas (25.4-28.58) (25.4-28.58) (25.4-28.58) (25.4-28.58) (28.58-31.75) (28.58-31.75)
High/Low 22.2 22.2 22.2 22.2 22.2 22.2
c
Pressure Gas (22.2-25.4) (22.2-25.4) (22.2-25.4) (22.2-25.4) (22.2-25.4) (22.2-25.4)
12.7 12.7 12.7 12.7 12.7 15.88
Liquid
(12.7-15.88) (12.7-15.88) (12.7-15.88) (12.7-15.88) (12.7-15.88) (15.88-19.05)

Outdoor Unit
38 40 42 44 46 48
(HP)
Combination Outdoor Unit A 24 22 24 22 24 24
Unit Outdoor Unit B 14 18 18 22 22 24
Piping Connection Kit MC-NP21SX
Low Pressure 38.1 38.1 38.1 38.1 38.1 38.1
Gas (38.1-41.3) (38.1-41.3) (38.1-41.3) (38.1-41.3) (38.1-41.3) (38.1-41.3)
High/Low 31.75 31.75 31.75 31.75 31.75 31.75
a
Pressure Gas (31.75-34.9) (31.75-34.9) (31.75-34.9) (31.75-34.9) (31.75-34.9) (31.75-34.9)
19.05 19.05 19.05 19.05 19.05 19.05
Liquid
(19.05-22.2) (19.05-22.2) (19.05-22.2) (19.05-22.2) (19.05-22.2) (19.05-22.2)
Low Pressure 28.58 28.58 28.58 28.58 28.58 28.58
Gas (28.58-31.75) (28.58-31.75) (28.58-31.75) (28.58-31.75) (28.58-31.75) (28.58-31.75)
High/Low 25.4 25.4 25.4 25.4 25.4 25.4
Piping Size b
Pressure Gas (25.4-28.58) (25.4-28.58) (25.4-28.58) (25.4-28.58) (25.4-28.58) (25.4-28.58)
15.88 15.88 15.88 15.88 15.88 15.88
Liquid
(15.88-19.05) (15.88-19.05) (15.88-19.05) (15.88-19.05) (15.88-19.05) (15.88-19.05)
Low Pressure 25.4 28.58 28.58 28.58 28.58 28.58
Gas (25.4-28.58) (28.58-31.75) (28.58-31.75) (28.58-31.75) (28.58-31.75) (28.58-31.75)
High/Low 22.2 22.2 22.2 25.4 25.4 25.4
c
Pressure Gas (22.2-25.4) (22.2-25.4) (22.2-25.4) (25.4-28.58) (25.4-28.58) (25.4-28.58)
12.7 15.88 15.88 15.88 15.88 15.88
Liquid
(12.7-15.88) (15.88-19.05) (15.88-19.05) (15.88-19.05) (15.88-19.05) (15.88-19.05)
* Perform the installation of the outdoor unit and piping connection according to the figure.
Refer to the table for the outdoor unit model, the piping connection kit model and the piping diameter.
* If the specified main refrigerant piping on the table is not available on site, follow the allowable piping size in parentheses.
When using the main refrigerant piping indicated in parentheses, prepare an appropriate reducer on site.

FAN-2207 201709 39

2-46 FAN-2209 201709


OUTDOOR UNIT

6.5.3 Piping Size between Outdoor Units (3 Units Combination)

(Indoor Unit on Left Side) (Indoor Unit on Right Side)


Outdoor Unit A Outdoor Unit B Outdoor Unit C Outdoor Unit C Outdoor Unit B Outdoor Unit A

a c d d c a
b e e b

Piping Connection Kit 1 Piping Connection Kit 2 Piping Connection Kit 2 Piping Connection Kit 1
To Indoor Units To Indoor Units

(fmm)
Model 50 52 54
Outdoor Unit A 18 18 18
Combination
Outdoor Unit B 18 18 18
Unit
Outdoor Unit C 14 16 18
Piping Connection Kit MC-NP30SX
Low Pressure 38.1 38.1 38.1
Gas (38.1-41.3) (38.1-41.3) (38.1-41.3)
High/Low 31.75 31.75 31.75
a
Pressure Gas (31.75-34.9) (31.75-34.9) (31.75-34.9)
19.05 19.05 19.05
Liquid
(19.05-22.2) (19.05-22.2) (19.05-22.2)
Low Pressure 31.75 31.75 31.75
Gas (31.75-34.9) (31.75-34.9) (31.75-34.9)
High/Low 28.58 28.58 28.58
b
Pressure Gas (28.58-31.75) (28.58-31.75) (28.58-31.75)
19.05 19.05 19.05
Liquid
(19.05-22.2) (19.05-22.2) (19.05-22.2)
Low Pressure 28.58 28.58 28.58
Gas (28.58-31.75) (28.58-31.75) (28.58-31.75)
High/Low 22.2 22.2 22.2
Piping Size c
Pressure Gas (22.2-25.4) (22.2-25.4) (22.2-25.4)
15.88 15.88 15.88
Liquid
(15.88-19.05) (15.88-19.05) (15.88-19.05)
Low Pressure 28.58 28.58 28.58
Gas (28.58-31.75) (28.58-31.75) (28.58-31.75)
High/Low 22.2 22.2 22.2
d
Pressure Gas (22.2-25.4) (22.2-25.4) (22.2-25.4)
15.88 15.88 15.88
Liquid
(15.88-19.05) (15.88-19.05) (15.88-19.05)
Low Pressure 25.4 28.58 28.58
Gas (25.4-28.58) (28.58-31.75) (28.58-31.75)
High/Low 22.2 22.2 22.2
e
Pressure Gas (22.2-25.4) (22.2-25.4) (22.2-25.4)
12.7 12.7 15.88
Liquid
(12.7-15.88) (12.7-15.88) (15.88-19.05)
* Perform the installation of the outdoor unit and piping connection according to the figure.
Refer to the table for the outdoor unit model, the piping connection kit model and the piping diameter.
* If the specified main refrigerant piping on the table is not available on site, follow the allowable piping size in parentheses.
When using the main refrigerant piping indicated in parentheses, prepare an appropriate reducer on site.

40 FAN-2207 201709

FAN-2209 201709 2-47


OUTDOOR UNIT

6.5.4 Stop Valve


Comply with the restrictions for refrigerant piping (permissible length, height difference) in the item 6.5.5
“Piping Connection”. If not, the outdoor unit may be damaged or fail.
The stop valves shall be closed completely (factory setting) when the refrigerant piping connection is
performed. Do not open the stop valves until all the refrigerant piping connections, air-tight test and
vacuuming have been completed.
< Gas Valve >
(1) Make sure that all the spindles are closed completely.
(2) Connect the charging hose to the service port and release the gas inside the piping from the gas pipe.
(3) Cut the end of the closing pipe and check that no gas exists inside the gas pipe.
(4) Remove the stop valve cover.
(5) Remove the closing pipe from the brazing portion with a burner.
Pay attention to the flame from the burner not to burn the stop valve body.

Service Port
Stop Valve for Gas Valve
(High/Low Pressure)
Stop Valve for Liquid Valve
Stop Valve for Stop Valve for Gas Pipe (Body)
Liquid Valve (High/Low Pressure)
Stop Valve for Gas Valve
(Low Pressure) Heat Exchanger Fin
Heat Stop Valve for Gas Pipe (Body)
Exchanger (Low Pressure)
Stop Valve Cover
(Read the precautions.)
Field-Work Side

Metal Plate for


Protection
End of Closing Pipe (φ6.35) Valve Stay
Closing Pipe
Torch
Cutting Portion
(φ6.35 Pipe)
Cut Here Closing Pipe
Fig. 6.2

l Ensure that there is no gas inside the pipe when removing the closing pipe.
Otherwise, the pipe may be blown out and it may lead to injury.
l Do not expose surrounding parts and the oil return pipe of the compressor to flames when torch
is used. If the oil return piping is exposed to the fire, high temperature oil will spurt and cause a
fire or injury.

< Liquid Valve > Outdoor


Tighten the flare nut for liquid stop valve according Unit Tightening Torque (N-m) Valve Type
(HP)
to the following torque. If an excessive force is 8 - 12 33 - 42 A
applied to the flare nut, the refrigerant leakage may 14 - 18 50 - 62 B
occur from the spindle part. (Put two spanners at the
20 - 24 68 - 84 C
positions indicated in the figure when removing and
connecting the piping. If not, the refrigerant leakage
may occur.)
Do not put two spanners here.

Do not put two spanners here.


Refrigerant leakage may occur.
A B C

Flare Nut

Flare Nut Flare Nut


Two Spanners Work Tightening Work for Stop Valve (Liquid) Put two spanners here.

l Do not apply an excessive force to the spindle valve after fully opening the spindle.
The back seat construction is not provided.
l At the test run, fully open the spindle. If it is not fully opened, the devices will be damaged.

FAN-2207 201709 41

2-48 FAN-2209 201709


OUTDOOR UNIT

● The details of stop valves is as follows.

< High/Low Pressure, Low Pressure Gas Valve >


Hexagonal Wrench Check Joint for Service Port
Wrench Size:10mm Tightening Torque: 9.0 - 14.0 N-m

Refrigerant Pressure

Cap
Tightening Torque: 49.0 - 58.0 N-m
Spindle Valve
Counterclockwise...Open
Clockwise...............Close Tightening Torque (N-m)
Tightening Torque: (a) N-m
Spindle Valve (a)
Outdoor Unit
(HP) High/Low Low Pressure
Pressure Gas Gas
8 - 12 18.0 - 22.0 18.0 - 22.0
14 - 24 18.0 - 22.0 25.0 - 31.0

< Liquid Valve >


Check Joint for Service Port
Only the charging hose
can be connected.
Tightening Torque: 14.0 - 18.0 N-m

Cap
Tightening Torque: (b) N-m
O-ring
Hexagonal Wrench Refrigerant Pressure
To open or close
spindle valve
Wrench Size: (e)

Spindle Valve
Counterclockwise...Open
Clockwise...............Close
Tightening Torque: (c) N-m
Flare Nut
Tightening Torque: (d) N-m
Refrigerant Piping

Tightening Torque (N-m)


Outdoor Unit Wrench Size
(HP) Cap Spindle Valve Flare Nut (e) (mm)
(b) (c) (d)
8 - 12 33.0 - 42.0 7.0 - 9.0 33.0 - 42.0 4
14 - 18 33.0 - 42.0 7.0 - 9.0 50.0 - 62.0 4
20 - 24 50.0 - 62.0 9.0 - 11.0 68.0 - 84.0 5

l Do not apply an excessive force to the spindle valve after fully opening the spindle.
The back seat construction is not provided.
l At the test run, fully open the spindle. If it is not fully opened, the devices will be damaged.

42 FAN-2207 201709

FAN-2209 201709 2-49


OUTDOOR UNIT

6.5.5 Piping Connection


After connecting the pipes, remove the caps of stop valves for gas and liquid.
Tighten the open-close spindle in the closing direction according to the following tightening torque.
(1) Make sure that the stop valves are closed completely.
(2) Protect the compressor and sound-proof cover with a metal plate when brazing the gas pipe as shown
in Fig. 6.2.
Pay attention to the flame from the burner not to burn the stop valve body.
(3) Connect the indoor unit and outdoor units with refrigerant piping. Fix the pipes and take special care
not to contact with weak portions such as wall, ceiling, etc. (Otherwise, abnormal sound may be heard
due to vibration of the piping.)
NOTE:
When on-site piping with joint such as elbow or socket is buried, provide a service access door to
facilitate the check for connecting part.
(4) As for the flaring work of the field pipe, use the specified tightening torque in Table 6.3.
Put nitrogen gas into the pipe when brazing the piping.
(5) Insulate the gas pipe and liquid pipe completely.
(6) Mount the piping cover equipped with the outdoor unit after the piping connection.
If not, the unit may damaged due to snow or rain water entering the piping.

Table. 6.3 Tightening Work of Flare Nut


Required Tightening Torque (JIS B8607)
Pipe Size Tightening Torque
f6.35 (1/4) 14 to 18 (N-m)
f9.52 (3/8) 34 to 42 (N-m)
f12.7 (1/2) 49 to 61 (N-m)
f15.88 (5/8) 68 to 82 (N-m)
f19.05 (3/4) 100 to 120 (N-m)

FAN-2207 201709 43

2-50 FAN-2209 201709


OUTDOOR UNIT

● Details of Stop Valve Piping Connection

JTOR080VPE(U, F, R)BS1 JTOR010VPE(U, F, R)BS1


Stop Valve Stop Valve
(High/Low Pressure Gas) (High/Low Pressure Gas)
Stop Valve Stop Valve
Stop Valve (Liquid) (Low Pressure Gas) Stop Valve (Liquid) (Low Pressure Gas)

Flaring Flaring
Liquid Pipe 90° Elbow B Liquid Pipe 90° Elbow B
(Field Supplied) (Field Supplied) (Field Supplied) (Field Supplied)
90° Elbow B 90° Elbow B
(Field Supplied) (Field Supplied)
Gas Pipe
Accessory Pipe (B) Accessory Pipe (A) Accessory Pipe (B) (Field Supplied)

JTOR120VPE(U, F, R)BS1 JTOR140VPE(U, F, R)BS1


Stop Valve Stop Valve
(High/Low Pressure Gas) (High/Low Pressure Gas)
Stop Valve Stop Valve
Stop Valve (Liquid) (Low Pressure Gas) Stop Valve (Liquid) (Low Pressure Gas)

Flaring
Flaring
Accessory Pipe (C) 90° Elbow B 90° Elbow B
Liquid Pipe
90° Elbow B (Field Supplied) (Field Supplied) (Field Supplied)
(Field Supplied)
90° Elbow B
90° Elbow A
(Field Supplied) (Field Supplied)
Gas Pipe Gas Pipe
Accessory Pipe (A) Gas Pipe
(Field Supplied) (Field Supplied)
(Field Supplied)

JTOR160VPE(U, F, R)BS1 JTOR180VPE(U, F, R)BS1


Stop Valve Stop Valve
(High/Low Pressure Gas) (High/Low Pressure Gas)
Stop Valve Stop Valve
Stop Valve (Liquid) (Low Pressure Gas) Stop Valve (Liquid) (Low Pressure Gas)

Flaring
Flaring
90° Elbow B Accessory Pipe (C) 90° Elbow B
Liquid Pipe
(Field Supplied) (Field Supplied) 90° Elbow B (Field Supplied)
(Field Supplied)
90° Elbow B
90° Elbow A
(Field Supplied) (Field Supplied)
Gas Pipe Accessory Pipe (A) Gas Pipe
Accessory Pipe (A)
(Field Supplied) (Field Supplied)

JTOR200VPE(U, F, R)BS1 JTOH220 - 240-VPE(U, F, R)BS1


Stop Valve Stop Valve
(High/Low Pressure Gas) (High/Low Pressure Gas)
Stop Valve Stop Valve
Stop Valve (Liquid) (Low Pressure Gas) Stop Valve (Liquid) (Low Pressure Gas)

Flaring Flaring
Liquid Pipe 90° Elbow B Liquid Pipe 90° Elbow B
(Field Supplied) (Field Supplied) (Field Supplied) (Field Supplied)
90° Elbow B 90° Elbow B
(Field Supplied) (Field Supplied)
Gas Pipe Gas Pipe
Gas Pipe Accessory Pipe (B)
(Field Supplied) (Field Supplied)
(Field Supplied)

NOTES:
1. Ensure that the closing pipe of the gas stop valve is removed firstly.
2. Refer to the item 6.2 for the flaring work.

NOTE
When connecting the outdoor unit gas stop valve and the field-supplied
refrigerant pipe, do not apply excessive force to the stop valve pipe as
illustrated on the right.
This may loosen the stop valve spindle.

44 FAN-2207 201709

FAN-2209 201709 2-51


OUTDOOR UNIT

● Construction Example
The following figures show the examples of 3 units combination.
Regarding the piping work for Combination Unit, refer to “Installation & Maintenance Manual” attached to
the piping connection kit.

For Piping from Front Side Piping Cover


- Perform the piping connection between
Piping Connection Kit 1 (Liquid) outdoor units according to this figure.
High/Low Pressure Gas Piping
(Field-Supplied) - Refer to “Installation & Maintenance Manual”
Accessory Pipe Indoor Unit A of the outdoor unit for the dimension and
distance between outdoor units and between
Liquid Piping piping connection kits.
(Field-Supplied) Piping Connection Kit 2 (Liquid)

Accessory
Indoor Unit B
Pipe
Indoor Unit C

Foundation

P
Low Pressure Gas Piping
(Field-Supplied)
Accessory Pipe <View from P>
Piping Connection Kit 1 (L-Shape)
(Low Pressure Gas)
Foundation
Accessory
Low Pressure Gas Piping Pipe
Piping Connection Kit 1
(Field-Supplied)
(High/Low Pressure Gas)
Accessory Pipe
High/Low Pressure Gas Piping
(L-Shape)
(Field-Supplied)
Piping Connection Kit 2
(Low Pressure Gas)
Piping Connection Kit 2 Liquid Piping
(High/Low Pressure Gas) High/Low Pressure Gas Piping
(Field-Supplied) ˃ 500mm (Field-Supplied)

For Piping from Bottom Base


- Perform the piping connection between
outdoor units according to this figure.
Piping Connection Kit 1 Outdoor Unit A
- Refer to “Installation & Maintenance Manual”
(Liquid) Accesory Pipe of the outdoor unit for the dimension and
(Z-Shape) distance between outdoor units and between
Piping Connection Kit 2
(Liquid) piping connection kits.
Liquid Piping
(Field-Supplied)

Accesory Pipe
(Z-Shape)
High/Low Pressure Gas Piping
(Field-Supplied) Outdoor Unit B
Base
Low Pressure Gas Piping (Field-Supplied)
(Field-Supplied)

Piping Connection Kit 1


(High/Low Pressure Gas)
Accesory Pipe
Piping Connection Kit 1
(L-Shape)
(Low Pressure Gas)

Piping Connection Kit 2


(High/Low Pressure Gas) Accesory Pipe
(L-Shape)
Piping Connection Kit 2
(Low Pressure Gas)
Outdoor Unit C
High/Low Pressure
Liquid Piping Gas Piping Low Pressure Gas Piping
(Field-Supplied) (Field-Supplied) (Field-Supplied)

NOTE:
The figure shows the case that the refrigerant pipes are pulled out from the front side piping cover.
They can be also pulled out from the bottom base hole.

FAN-2207 201709 45

2-52 FAN-2209 201709


OUTDOOR UNIT

● Piping Size and Multi-Kit Selection

For selecting the pipe sizes between the outdoor unit and the piping connection kit 1 , between the piping
connection kits 2 and for piping connection kit A , refer to the items from 6.5.1 to 6.5.3 “Piping Size between
Outdoor Units”.

* Maintain a straight-line distance of 500mm or more


for piping after the piping connection kit.

Outdoor Outdoor Outdoor 5 Low Pressure Three Pipes Portion


Unit Unit Unit Gas Pipe
A B C
A
5 High/Low Pressure CH
1 1 1 6 7 Liquid Pipe
* Gas Pipe

3 6 7 Gas Pipe Two Pipes Portsion


2
* A
CH-Box is not connected to liquid pipe.
B
C
4 C 4

5 5 5
E E E
CH CH CH
4
7 7 7 5 High/Low Pressure Gas Pipe
Three Pipes Portion
Indoor Indoor Indoor
Unit Unit Unit 5 Low Pressure Gas Pipe
C
5
CH-M CH-M
E 7 7 7 7 5 Liquid Pipe
Indoor Indoor Indoor Indoor 6 7 Gas Pipe
Unit Unit Unit Unit 6 7 Gas Pipe
6 7 Liquid Pipe
C 6 7 Liquid Pipe
• • • *3
5 6 6
CH Two Pipes Portsion
E D D Two Pipes Portsion
6 7 7 7
Indoor Indoor Indoor Refer to page 54 “ E CH-Box” for details of branch number
Unit Unit Unit

D
: High/Low Pressure Gas Pipe,
7 7 Low Pressure Gas Pipe, Liquid Pipe
Terminal
Indoor Indoor Unit : Gas Pipe, Liquid Pipe
Unit
: Low Pressure Gas Pipe, Liquid Pipe
(Exclusive Use of Cooling Operation)
CH : CH-Box (Single Branch Type)
CH-M : CH-Box (Multiple Branch Type)

E F

Header Branch Header Branch


4 5 6
CH

5 5 5
CH CH CH
7 7 7 7 7 7
Indoor Indoor Indoor Indoor Indoor Indoor
Unit Unit Unit Unit Unit Unit

Header branch cannot be connected to upstream or downstream piping of CH-Box (multiple branch type).

46 FAN-2207 201709

FAN-2209 201709 2-53


OUTDOOR UNIT

Refer to the figure of previous page.

Multi-Kit (Optional Parts)

< Line Branch >


B First Branch D Multi-Kit after First Branch (2 Pipes Portion)
Outdoor Unit HP Model Total
Model
8, 10 MW-NP282X3 Indoor Unit HP
12 - 16 MW-NP452X3 < 12 MW-NP282A3
18, 20 MW-NP562X3 12 - 17.99 MW-NP452A3
22, 24 MW-NP692X3 18 - 25.99 MW-NP692A3
26 - 54 MW-NP902X3 > 26.00 MW-NP902A3

C Multi-Kit after First Branch (3 Pipes Portion) E For 2 Pipes Portion < Header Branch >
Total Total No. of Header
Model Model
Indoor Unit HP Indoor Unit HP Branches
<6 MW-NP142X3 5 - 10 8 JMH-NP288X
6 - 11.99 MW-NP282X3
12 - 17.99 MW-NP452X3
18 - 21.99 MW-NP562X3 F For 3 Pipes Portion < Header Branch >
22 - 25.99 MW-NP692X3 Total No. of Header
Model
> 26 MW-NP902X3 Indoor Unit HP Branches
5-8 4 JMH-NP224A
5 - 10 8 JMH-NP288A

FAN-2207 201709 47

2-54 FAN-2209 201709


OUTDOOR UNIT

Piping Size (fmm)

3 Main Pipe Diameter 4 [Pipe Diameter after First Branch] (3 Pipes)


(Base Unit or Piping Connection Kit 1 to First Branch) Low High/Low
[Multi-Kit of First Branch] (3 Pipes) Total Indoor Unit
Pressure Pressure Liquid
HP
Low High/Low Gas Gas
Outdoor Unit Pressure Pressure Liquid
HP <6 15.88 12.7 9.52
Gas Gas
6 - 8.99 19.05 15.88 9.52
8 19.05 15.88 9.52
9 - 11.99 22.2 19.05 9.52
10 22.2 19.05 9.52
12 - 15.99 25.4 22.2 12.7
12, 14 25.4 22.2 12.7
16 - 17.99 28.58 22.2 12.7
16 28.58 22.2 12.7
18 - 21.99 28.58 22.2 15.88
18, 20 28.58 22.2 15.88
22 - 25.99 28.58 25.4 15.88
22, 24 28.58 25.4 15.88
26 - 35.99 31.75 28.58 19.05
26 31.75 25.4 19.05
> 36 38.1 31.75 19.05
28 - 34 31.75 28.58 19.05
36 38.1 28.58 19.05 NOTE:
Even if the equivalent refrigerant piping length is more
38 - 54 38.1 31.75 19.05 than 100m, no need to increase the pipe size after first
NOTE: branch. If the multi-kit size is larger than the first branch,
When the maximum length of the equivalent refrigerant adjust the multi-kit size to the first branch. In case that
pipe (L1) from the piping connection kit 1 to the indoor the selected pipe size after the first branch is larger than
unit is over 100m, the pipe size of liquid line from the pipe size before the first branch, use the same pipe
the piping connection kit 1 to first branch should be size as before the branch.
increased by one size with reducers (field-supplied).

5 [Pipe Diameter between CH-Box to Multi-Kit]


Number of Available Combination
of Indoor Unit Capacity Low High/Low
Connectable
Type JCH-Box Model Branch (HP) Pressure Pressure Liquid
Indoor Unit
Gas Gas
per Branch per CH-Box per Branch
0.8 - 4.0 15.88 12.7 9.52
JCH-AP160SSX 1 1-7 *1
6.0
4.1 - 6.0 19.05 15.88 9.52
Single
6.1 - 8.0 19.05 15.88 9.52
JCH-AP280SSX 1 1-8 *1
10.0
8.1 - 10.0 22.2 19.05 9.52
JCH-AP04MSSX 4 1-6 *2
16.0 6.0 or less
JCH-AP08MSSX 8 1-6 *2
30.0 6.0 or less Refer to the 4 [Pipe Diameter after
Multiple
JCH-AP12MSSX 12 1-6 *2
30.0 6.0 or less First Branch] (3 Pipes).
JCH-AP16MSSX 16 1-6 *2
30.0 6.0 or less
NOTE:
*1: When multiple indoor units are connected to the same CH-Box, they are controlled with the same operation mode.
*2: The indoor units connected to the same branch of the CH-Box are controlled with the same operation mode.
* The liquid pipe is not required to connect to the CH-Box.
* In case that the number of connectable indoor unit exceeds four, the high/low pressure gas pipe, gas pipe and liquid
pipe 5 6 7 need to increase one size respectively.

6 [Pipe Diameter for 2 Pipes and Multi-Kit] 7 [Pipe Diameter between Multi-Kit and Indoor Unit]
Total Indoor Unit Indoor Unit HP Gas Liquid
Gas Liquid
HP 1.5 or less 12.7 6.35 (*)
<6 15.88 9.52 2.0 15.88 6.35 (*)
6 - 8.99 19.05 9.52 2.5 to 6.0 15.88 9.52
9 - 11.99 22.2 9.52 8.0 19.05 9.52
12 - 15.99 25.4 12.7 10.0 22.2 9.52
16 - 17.99 28.58 12.7 16.0 28.58 12.7
18 - 25.99 28.58 15.88 20.0 28.58 15.88
(*): When the liquid piping length is longer than 15m, use
f9.52 pipe and reducer (field-supplied).
NOTE:
The pipe diameter should be the same as the indoor unit
piping connection size.

48 FAN-2207 201709

FAN-2209 201709 2-55


OUTDOOR UNIT

Term Symbol Description


Example 1 a+b+c
Total Piping Length Total length of all liquid pipes (sum)
Example 2 d+e+f+g+h
Example 1 a+c Actual length of the liquid pipe from outdoor unit stop
Maximum Piping Length
Example 2 f+h valve or piping connecting kit to the terminal unit.
Actual length of liquid pipe out of consideration of local
Piping Length -
resistance, such as bent or elbow.
This length is obtained by converting local resistance,
Equivalent Length -
such as bent or elbow, to straight pipe length.

< Example 1 > Line Branch (Including Main Pipe Branch) < Example 2 > Using Piping Connection Kit

Outdoor Outdoor Outdoor


Unit A Unit B Unit A

a c e d f h

First Branch
b Piping Connection Kit
g
Indoor Terminal Indoor Terminal
Multi-Kit Unit Indoor Unit First Branch Unit Indoor Unit
Multi-Kit
A B A B

NOTE:
The main pipe branch is the piping branch method where
Multi-Kits are connected to the pipes both after the first branch.

a b
c Indoor Unit
Main Pipe d e
Branch
f

FAN-2207 201709 49

2-56 FAN-2209 201709


OUTDOOR UNIT

● Piping Work Conditions


Comply with the following when installing the unit.

Indicate what installer must comply with. This is not an example of compliance. Describe the limitation
shown in the drawing.

< For two and three units combination > Upstream Side

* Maintain a straight-line distance of


500mm or more for piping after Outdoor
Outdoor Outdoor
the piping connection kit. Unit
Unit Unit H5
C
A B
Indoor Unit Side
La Lb Lc
* *
Piping Piping
Connection Kit 1 Connection Kit 2

First Branch

L3
CH-M CH
L3
H6 H6
Indoor Indoor Indoor Indoor
Unit Unit Unit Unit

L3
e f
H4 g h i H1
Indoor Indoor Indoor
Unit Unit Unit
H2

e f
CH L1
i L2
g h L3
L3
Indoor Indoor
Indoor Unit Unit H3
Unit

(Exclusive Use of
Cooling Operation) Terminal
Indoor Unit
Header Branch Header Branch (CH-Box in Common Use)

CH
e

L3 CH CH CH f g h
L4 Indoor Indoor Indoor
Indoor Indoor Indoor Unit Unit Unit
Unit Unit Unit

: High/Low Pressure Gas Pipe, Low Pressure Gas Pipe, Liquid Pipe
: Gas Pipe, Liquid Pipe
: Low Pressure Gas Pipe, Liquid Pipe
CH : CH-Box (Single Branch Type)
CH-M : CH-Box (Multiple Branch Type)

50 FAN-2207 201709

FAN-2209 201709 2-57


OUTDOOR UNIT

Allowable Piping Length


Item Mark < the recommended > the recommended
connectable number connectable number
of Indoor Unit of Indoor Unit
Total Liquid Piping
Total Piping Length < 1,000m < 300m
Actual Length
Actual Length < 165m < 165m
Maximum Piping Length L1
Equivalent Length < 190m < 190m
Maximum Piping Length between
L2 < 90m < 40m
Multi-kit of 1st Branch and Each Indoor Unit
Maximum Piping Length between
L3 < 40m < 30m
Each Multi-kit and Each Indoor Unit
Total Piping Length between
e+f+g+h+i < 40m < 40m
CH-Box and Each Indoor Unit per Branch
Piping Length between Piping Connection Kit 1 and
La, Lb, Lc < 10m < 10m
Each Outdoor Unit
Height Difference between O.U. is Higher < 50m (*) < 50m (*)
H1
Outdoor Units and Indoor Units O.U. is Lower < 40m < 40m
Height Difference between Indoor Units H2 < 15m < 15m
Height Difference between
H3 < 4m < 4m
Indoor Units using the Same CH-Box
Height Difference between CH-Boxes H4 < 15m < 15m
Height Difference between Outdoor Units H5 < 0.1m < 0.1m
Height Difference between CH-Box and Indoor Units H6 < 15m < 15m
(*): Longer piping (up to 110m) is available all models.
Contact your distributer or dealer if the height difference is over 50m.

NOTES:
1. For 2 and 3 outdoor unit combination, the outdoor unit “A” should be connected to the piping connection kit 1.
(Refer to the items 6.5.2 for the outdoor unit models.)
The details of piping connection kit shall be referred to the installation manual of itself.
2. The piping length between outdoor units should be La < Lb < Lc < 10m.
(If the piping length is incorrect, it may cause failure of outdoor unit due to flowing back the refrigerant.)
3. Keep the straight line distance of 500mm or more after the piping connection kit.
4. For the exclusive cooling operation, connect indoor units with low pressure gas pipe and liquid pipe (without CH-
Box). The total capacity of the exclusive cooling operation should be smaller than 50% of the total indoor unit
capacity.
5. The condition of refrigerant piping installation is different depending on the connected indoor unit quantities.
Refer to the table 3.2 “System Combination” in item 3.2 for details.
6. Allowable total piping length may become shorter than 1,000m due to the limitation of maximum additional refrigerant
amount as following table.
HP 8, 10 12 14 - 18 20, 22 24 26 - 54
Max. Additional Refrigerant Charge (kg) 28 36 40 51 52 63

7. If the piping length (L3) between each multi-kit and indoor unit is considerably longer than other indoor unit,
refrigerant may not flow well and also performance may be deteriorated compared to other models.
(Recommended Piping Length: within 15m)
8. For the maximum pipe length of 100m or more, the liquid pipe size of the main pipe (the piping connection kit 1 to the
first branch) should be increased by one size with reducer (field-supplied).
9. In the case that the pipe length between the first branch and the terminal indoor unit is more than 40m, make sure to
follow “Piping Branch Restriction“ when installing.
10. Install the bent pipe or (horizontal) loop pipe to the on-site installed pipe in order to absorb the stretch of the
refrigerant pipe caused by the temperature change.
11. (*) in the table above is optional.
12. In the case that the height difference between the CH-Box and the indoor unit is large, performance may be
deteriorated.
13. The header branch cannot be connected to either before or after the multiple branch type CH-Box.

FAN-2207 201709 51

2-58 FAN-2209 201709


OUTDOOR UNIT

● Piping Branch Restriction


The number of the main piping branches is not limited under the following restrictions.
In the case that the piping length L2 from the Multi-Kit at the first branch to the farthest indoor unit is over
40m, follow the instructions below when performing the field-supplied piping work.

(Example 1) : Installation with Main Piping Branch (T)


Piping length from the Multi-Kit at the first branch to the terminal indoor unit is within 40~90m.

(1) In the case that the piping length L2 is over 40m, the size of gas and liquid lines “b and c” or “g and h”
should be increased by one size with reducers (field-supplied).
*If (a) is smaller than (b, g) after increasing the size, increase the size of (a) to the same size as (b, g).

(2) The difference between the piping length from the first branch to the farthest indoor unit and the piping
length from the first branch to the closest indoor unit must be within 40m.
*(g+h+j)-(b+d)<40m
Piping Length from the Multi-Kit at the first branch
to the terminal Indoor Unit is within 40 ~ 90m
L2

a b c e
d f
First Branch Terminal
Multi-Kit The Closest Indoor Unit Indoor Unit
from the First Branch‫ޓ‬
L2
g
j Terminal
h Indoor Unit
i k

The Farthest Indoor Unit


from the First Branch‫ޓ‬

(Example 2): Installation without Main Piping Branch (T)


Piping length from the Multi-Kit at the first branch to the terminal indoor unit is within 40~90m.

(1) In the case that L2 is over 40m, the size of gas and liquid lines “b, d and f” should be increased by one
size with reducers (field-supplied).
*If (a) is smaller than (b) after increasing the size, increase the size of (a) to the same size as (b).

Piping Length from the Multi-Kit at the first branch


to the terminal Indoor Unit is within 40 ~ 90m
L2

b d f h
a
c e g i Terminal
First Branch Indoor Unit
Multi-Kit
The Closest Indoor Unit The Farthest Indoor Unit
from the First Branch from the First Branch

(T): Main Piping Branch: Both of the pipes branched from a Multi-Kit are connected to the next Multi-Kits.

Header branch can be used with line branch. Header branch can also be used after the second branch.
Do not connect a line branch to a header branch. When using header branch, make sure that the piping
length L2 from the Multi-Kit at the first branch to the farthest indoor unit is within 40m.

Within 40m
Line Branch

Line Branch Line Branch

Header Branch

Header Branch
Indoor Unit
Within 40m

52 FAN-2207 201709

FAN-2209 201709 2-59


OUTDOOR UNIT

● Indoor Unit Installation


The number of connectable indoor unit with outdoor unit is as follows.
Comply with the condition as follows when installation.

Maximum Number of Connectable Indoor Units and Rang of Combination Capacity


Outdoor Unit Capacity
5 6 8 10 12 14 16, 18 20 22 24 26 28 30 32 34 36 38 - 54
(HP)
Range of Combination
50 to 130% (In case the combination ratio exceed 130%) *
Capacity
Connectable
8 9 13 16 19 23 26 33 36 40 43 47 50 53 56 59 64
Indoor Units Q’ty
Recommended Connectable
5 8 10 16 18 20 26 32 38
Indoor Units Q’ty

NOTES:
1. The connectable indoor unit capacity ratio can be calculated as follows.
Connectable Indoor Unit Capacity Ratio = Total Indoor Unit Capacity / Total Outdoor Unit Capacity
2. For the system under which all the indoor units are supposed to operate simultaneously, the total
indoor unit capacity should be less than outdoor unit capacity. Otherwise, it may cause a decrease of
operating performance and operating limit in overload operation.
3. For the system under which all the indoor units are not supposed to operate simultaneously, the total
indoor unit capacity is available up to 130% against the outdoor unit capacity.
4. When operating the outdoor unit in cold areas with temperatures of -10oC, or under the high heating
load conditions, the total indoor unit capacity should be less than 100% against the outdoor unit
capacity and the total piping length should be less than 300m.
5. The air flow volume for indoor units of 0.8 and 1.0HP is set higher than that for indoor units of
1.5HP or more. Make sure to select appropriate indoor units when installing indoor units where
cold draft may occur during heating operation. If installing indoor units in such places, refer to the
recommended number of connectable indoor units.
6. For connecting Tempclean Indoor Unit and Outdoor Air Processing Air Conditioner, the number of the
indoor units should be within recommended connectable indoor units number.
7. If combination capacity of indoor units exceed 100% of outdoor unit capacity, there might be the
possibility of insufficient capacity of 130% combination ratio. Refer to the technical catalog for the
detail. If combination capacity exceed 130% contact your distributer or dealer.
* Contact your distributer or dealer if the capacity of combination ratio exceed 130%.
The system configuration exceed combination ratio of 130% without consultation with distributer or
dealer is not acceptable. It may cause activation of alarm and operation failure.

The load capacity per hour or the possibility of all indoor units simultaneous operation is unknown at the design
stage, the total capacity of combined indoor units should be not over 100% against the outdoor unit capacity.

FAN-2207 201709 53

2-60 FAN-2209 201709


OUTDOOR UNIT

7. Electrical Wiring

l Turn OFF the main power switch of the indoor unit and the outdoor unit and wait for more than
3 minutes before electrical wiring work or a periodical check is performed.
l Check to ensure that the indoor fan and the outdoor fan have stopped before electrical wiring work
or a periodical check is performed.
l Protect the wires, electrical parts, etc. from rats or other small animals.
If not, rats may gnaw at unprotected parts, which may lead to a fire.
l Avoid the wirings from touching the refrigerant pipes, plate edges and electrical parts inside the
unit. If not, the wires will be damaged and at the worst, a fire will occur.
l Use a medium sensing speed type ELB (Earth Leakage Breaker, activation speed of 0.1 sec. or
less). If not, it will cause an electric shock or a fire.
l Fix the cables securely. External forces on the terminals could lead to a fire.
l Tighten screws according to the following torque.
M4: 1.0 to 1.3 N-m
M5: 2.0 to 2.5 N-m
M6: 4.0 to 5.0 N-m
M8: 9.0 to 11.0 N-m
M10: 18.0 to 23.0 N-m
l Set DSW7 on the PCB1 according to each power supply shown in the figure below.

DSW7 (PCB1) Power Supply Voltage and SystemSetting

No setting is required.
220V Unit: 220V Setting Before Shipment
380V Unit: 380V Setting Before Shipment
400V Unit: 400V Setting Before Shipment
460V Unit: 460V Setting Before Shipment

Setting is required.
380-415V Unit: 415V Setting Before Shipment

Power Supply Voltage and System Setting

220V 380V 460V

Heat Pump ON ON ON
(2 Pipes) OFF OFF OFF
1 2 3 4 1 2 3 4 1 2 3 4

l The electrical wiring work must be performed by authorized installers in order to prevent an electric
shock or a fire.
l Perform the electrical work according to the regulation of each region and “Installation &
Maintenance Manual”, and the dedicated electrical circuit must be used. If the electrical wiring
work is performed incorrectly or there is a capacity shortage of the power circuit, it will cause an
electric shock or a fire.
l Use the specified cables for wiring between the outdoor unit and indoor units. Selecting incorrect
cables will cause an electric shock or a fire.
l Tightly secure the wirings to the terminal block according to the specified torque. If tightening the
terminals is not completed, heat generation, an electric shock or a fire will occur at the terminal
connections.
l Tightly clamp the wires with a cord clamp after the wiring to the terminal block has been completed.
In addition, run securely the wires through the wiring hole. If not, the wires will be pinched and it
may cause a fire.
l Turn OFF the power source when handling the service connector. Otherwise, it may cause an
electric shock.

54 FAN-2207 201709

FAN-2209 201709 2-61


OUTDOOR UNIT

7.1 General Check


(1) Make sure that the field-selected electrical components (main power switches, circuit breakers, wires,
conduit connectors and wire terminals) have been properly selected according to the electrical data
indicated in Table 7.1 and 7.2. Make sure that the components comply with National Electrical Code
(NEC).
• Supply electrical power to each outdoor unit. ELB, fuse and main switch should be installed for each
outdoor unit. If not, it will cause a fire or an electrical shock.
• The power sources for the indoor unit and outdoor unit should be supplied respectively.
Connect the power supply wiring to each indoor unit group connected to the same outdoor unit.
(Max. capacity of one indoor unit group is 26HP.) ELB, fuse and main switch should be installed for
each indoor unit group. Refer to “Installation & Maintenance Manual” attached to the indoor unit.
(2) Check to ensure that the power supply voltage is within ±10% of the rated voltage.
If the power supply voltage is too low, the system cannot start due to the voltage drop.
(3) Check the size of the electrical wires.
(4) The packaged air conditioner may not operate normally in the following cases.
• In case that the power source for the packaged air conditioner is supplied from the same power
transformer as the device with high electricity consumption*
• In case that the power supply wiring for the device* and for the packaged air conditioner are located
close to each other.
* (ex) Lift, container crane, rectifier for electric railway, inverter power device, arc furnace,
electric furnace, large-sized induction motor and large-sized switch.
In the cases mentioned above, induction surge of the power supply wiring for the packaged air
conditioner could occur due to a rapid change in electricity consumption of the device and activation of
switch. Therefore check the field regulations and standards before performing electrical work in order
to protect the power supply wiring for the packaged air conditioner.
(5) Check to ensure that the earth wire of the outdoor unit, indoor unit are connected.

7.2 Electrical Wiring Connection

l The ELB (earth leakage breaker), FUSE and S (main switch) must be installed for each outdoor unit
and also for each indoor unit group. If not, it may cause an electrical shock or fire.
l Perform the electrical work according to the regulation of each region and “Installation &
Maintenance Manual”, and the dedicated electrical circuit must be used. If the electrical wiring
work is performed incorrectly or there is a capacity shortage of the power circuit, it will cause an
electric shock or a fire.
l Check that the ground wire is securely connected. If the unit is not correctly grounded, it may lead
to an electrical shock.
Do not connect the ground wiring to a gas piping, water piping, lighting conductor or ground wiring
for telephone.
l The power sources for the indoor unit and outdoor unit should be supplied respectively.
l The power source for each indoor unit group should be supplied respectively.

FAN-2207 201709 55

2-62 FAN-2209 201709


OUTDOOR UNIT

(1) Power Source Wiring


Supply the power sources to each outdoor unit and indoor unit group respectively.
Power source wiring is fundamentally according to this method.

1 ELB (Earth Leakage Breaker)


2 FUSE
Outdoor Unit Power Source
3~, 460V/60Hz 3 S (Main Switch)
3~/N, 380V/60Hz 4 Power Source Wiring (O.U.)
3~, 220V/60Hz
5 Earth Wiring (O.U.)
6 Transmission Wiring (O.U. ~ I.U.)
1 ELB 1 ELB 1 ELB 7 Transmission Wiring (O.U. ~ O.U.)
8 Transmission Wiring (CH-Box ~ CH-Box)
2 FUSE 2 FUSE 2 FUSE
9 Transmission Wiring (I.U. ~ CH-Box)
3 S 3 S 3 S
10 Power Source Wiring (I.U. ~ CH-Box)
11 Earth Wiring (I.U., CH-Box)
4 4 4

Indoor Unit Side


Outdoor Outdoor Outdoor
Unit Unit Unit 6 8 8
C 5 B 5 A 5
9 9
CH 11 CH 11
7 7 10 10 10

10 10 10
S
FUSE
Indoor Indoor
ELB Unit 11 Unit 11

Indoor Unit, CH-Box


Power Source
1N~ 230V/50Hz
1N~ 220-240V/50Hz
1N~ 220V/60Hz
1~ 220V/60Hz

(2) The recommended wire size and main switch( 1 ~ 8 ) are shown in Table 7.1.
Please refer to the indoor units and CH-Box installation manual for other cables ( 9 ~ 11 ).
• Select the capacity of power transformer according to the maximum running current.
• When the power supply wiring is too long, select the minimum wiring size whose voltage drop is within
2%.
• Power supply voltage should comply with the following requirements.
Supply Voltage: Rated Voltage within ±10%
Starting Voltage: Rated Voltage within -15%
Operating Voltage: Rated Voltage within ±10%
Imbalance between Phases: within 3%
• Calculate short-circuit current from the power transformer and electrical wiring length and size, and
select the appropriate rated capacity for ELB (earth leakage breaker).
• Select ELB which can be used for the high harmonic wave.

l Do not connect the earth wire to the gas pipe, water pipe or lightening conductor.
Gas Pipe: An explosion and ignition may occur when gas leaks.
Water Pipe: Earth wire becomes ineffective when a hard vinyl pipe is used.
Lightning Conductor: The earth electric potential abnormally increases
when a lightening conductor is used.

56 FAN-2207 201709

FAN-2209 201709 2-63


OUTDOOR UNIT

(3) The recommended wiring, ELB, breaker size are shown in Table 7.1 and 7.2.
Table 7.1 Electrical Data and Recommended Wiring, Breaker Size/1 Outdoor Unit

3
1 ELB
Maximum Main Switch
Power
Running Nominal
Model Power Supply Supply Line Nominal Nominal 2 Fuse
Current Sensitive
Current Current
Current
(A) (fmm) (A) (mA) (A) (A)
JTOR080VPEUBS1 14.0 MLFC 2.0SQ 20 30 20 20
JTOR100VPEUBS1 19.0 MLFC 3.5SQ 30 30 25 25
JTOR120VPEUBS1 21.0 MLFC 3.5SQ 30 30 25 25
JTOR140VPEUBS1 26.0 MLFC 5.5SQ 30 30 32 32
JTOR160VPEUBS1 460V/60Hz 29.5 MLFC 5.5SQ 40 30 40 40
JTOR180VPEUBS1 33.5 MLFC 5.5SQ 40 30 40 40
JTOR200VPEUBS1 39.5 MLFC 8.0SQ 50 30 50 50
JTOR220VPEUBS1 40.0 MLFC 8.0SQ 50 30 50 50
JTOR240VPEUBS1 47.5 MLFC 14.0SQ 60 30 63 63
JTOR080VPEFBS1 15.5 MLFC 2.0SQ 20 30 20 20
JTOR100VPEFBS1 21.5 MLFC 3.5SQ 30 30 25 25
JTOR120VPEFBS1 24.0 MLFC 3.5SQ 30 30 25 25
JTOR140VPEFBS1 29.5 MLFC 5.5SQ 30 30 32 32
JTOR160VPEFBS1 380V/60Hz 33.0 MLFC 5.5SQ 40 30 40 40
JTOR180VPEFBS1 37.5 MLFC 5.5SQ 40 30 40 40
JTOR200VPEFBS1 44.5 MLFC 8.0SQ 50 30 50 50
JTOR220VPEFBS1 45.0 MLFC 8.0SQ 50 30 50 50
JTOR240VPEFBS1 53.0 MLFC 14.0SQ 60 30 63 63
JTOR080VPERBS1 25.5 MLFC 3.5SQ 30 30 30 30
JTOR100VPERBS1 35.0 MLFC 5.5SQ 40 30 60 40
JTOR120VPERBS1 39.0 MLFC 8.0SQ 40 30 60 40
JTOR140VPERBS1 48.0 MLFC 14.0SQ 50 30 60 50
JTOR160VPERBS1 220V/60Hz 54.5 MLFC 14.0SQ 60 30 60 60
JTOR180VPERBS1 61.5 MLFC 14.0SQ 75 30 75 75
JTOR200VPERBS1 72.5 MLFC 22.0SQ 75 30 75 75
JTOR220VPERBS1 73.5 MLFC 22.0SQ 75 30 75 75
JTOR240VPERBS1 87.0 MLFC 22.0SQ 100 30 100 100
ELB: Earthleakage Breaker, MLFC: Flame Retardant Polyflex Wire
Install main switch and ELB for each system separately. Select the high response type of ELB that acts
within 0.1 second.

FAN-2207 201709 57

2-64 FAN-2209 201709


OUTDOOR UNIT

n Field Minimum Wire Sizes for Power Source and Transmission


4 Power Source Cable 6 7 8 Transmitting Cable
Maximum 5
Size Size
Running Earth Wire
Model Power Supply EN60 335-1 MLFC EN60 335-1 MLFC
Current Size
*1 *2 *1 *2
(A) (mm2) (mm2) (mm2) (mm2) (mm2)
JTOR080VPEUBS1 14.0 2.5 2.0 0.75 0.75 2.0
JTOR100VPEUBS1 19.0 2.5 3.5 0.75 0.75 2.0
JTOR120VPEUBS1 21.0 2.5 3.5 0.75 0.75 2.0
JTOR140VPEUBS1 26.0 4.0 5.5 0.75 0.75 3.5
JTOR160VPEUBS1 460V/60Hz 29.5 6.0 5.5 0.75 0.75 3.5
JTOR180VPEUBS1 33.5 6.0 5.5 0.75 0.75 3.5
JTOR200VPEUBS1 39.5 10.0 8.0 0.75 0.75 3.5
JTOR220VPEUBS1 40.0 10.0 8.0 0.75 0.75 3.5
JTOR240VPEUBS1 47.5 10.0 14.0 0.75 0.75 3.5
JTOR080VPEFBS1 15.5 2.5 2.0 0.75 0.75 2.0
JTOR100VPEFBS1 21.5 2.5 3.5 0.75 0.75 2.0
JTOR120VPEFBS1 24.0 2.5 3.5 0.75 0.75 2.0
JTOR140VPEFBS1 29.5 4.0 5.5 0.75 0.75 3.5
JTOR160VPEFBS1 380V/60Hz 33.0 6.0 5.5 0.75 0.75 3.5
JTOR180VPEFBS1 37.5 6.0 5.5 0.75 0.75 3.5
JTOR200VPEFBS1 44.5 10.0 8.0 0.75 0.75 3.5
JTOR220VPEFBS1 45.0 10.0 8.0 0.75 0.75 3.5
JTOR240VPEFBS1 53.0 10.0 14.0 0.75 0.75 3.5
JTOR080VPERBS1 25.5 4.0 3.5 0.75 0.75 2.0
JTOR100VPERBS1 35.0 6.0 5.5 0.75 0.75 3.5
JTOR120VPERBS1 39.0 6.0 8.0 0.75 0.75 3.5
JTOR140VPERBS1 48.0 10.0 14.0 0.75 0.75 3.5
JTOR160VPERBS1 220V/60Hz 54.5 - 14.0 0.75 0.75 5.5
JTOR180VPERBS1 61.5 - 14.0 0.75 0.75 5.5
JTOR200VPERBS1 72.5 - 22.0 0.75 0.75 5.5
JTOR220VPERBS1 73.5 - 22.0 0.75 0.75 5.5
JTOR240VPERBS1 87.0 - 22.0 0.75 0.75 5.5
* Refer to the NOTES for selection of the power source cable size.

58 FAN-2207 201709

FAN-2209 201709 2-65


OUTDOOR UNIT

NOTES:
1) Follow the local codes and regulations when selecting field wires.
2) The wire sizes marked with *1 in the table of the previous page are selected at the maximum current of the unit
according to the European Standard, EN60 335-1. Use the wires which are not lighter than the ordinary tough
rubber sheathed flexible cord (code designation H05RN-F) or ordinary polychloroprene sheathed flexible cord (code
designation H05RN-F).
3) The wire sizes marked with *2 in the table of the previous page are selected at the maximum current of the unit
according to the wire, MLFC (Flame Retardant Polyflex Wire) manufactured by Hitachi Cable Ltd., Japan.
4) Use a shielded cable for the transmitting circuit and connect it to the ground.
5) In the case that power cables are connected in series, add apply maximum current to each unit and select appropriate
wires in the table below.

Selection According to MLFC (at Cable Temperature of 90oC,


Selection According to EN60 335-1
Field Ambient Temperature 52oC and Cables are Tied Together)
Current i (A) Wire Size (mm2) Current i (A) Wire Size (mm2)
i< 6 0.75 i < 11 0.75 *3: In the case that
6 < i < 10 1 11 < i < 14 1.25 current exceeds 63A,
10 < i < 16 1.5 14 < i < 20 2 use MLFC cables.
16 < i < 25 2.5 20 < i < 28 3.5
25 < i < 32 4 28 < i < 38 5.5
32 < i < 40 6 38 < i < 47 8
40 < i < 63 10 47 < i < 68 14
63 < i *3 68 < i < 90 22
90 < i < 108 30

NOTE:
Use 2-core cable (equivalent to following cables: VCTF, VCT, CVV, MVVS, VVR or VVF, size: 0.75mm2 to 1.25mm2
(manufactured by HITACHI Cable Co. Ltd.)) or 2-core twist pair cable (equivalent to following cables: KPEV or KPEV-S
(manufactured by HITACHI Cable Co. Ltd.)) for the control cable between the outdoor unit and the indoor unit.
The total transition wiring length between the indoor unit and the outdoor unit should be less than 1000m and the total
transition wiring length between outdoor units should be less than 30m.

Install a multi-pole main switch with a space of 3.5mm or more between each phase.

FAN-2207 201709 59

2-66 FAN-2209 201709


OUTDOOR UNIT

7.3 Electrical Wiring for Outdoor Unit


Connect the electrical wirings according to the following figures.
(1) Connect the power supply wires to L1, L2, L3, and N (for 380V, 460V) for the three phase power
source on the terminal block TB1 and earth wire to the terminal in the electrical box.
Connect the power supply wires to R, S, T (for 220V) for the three phase power source on the terminal
block TB1 and earth wire to the terminal in the electrical box.
(2) Connect the transmission wires between the outdoor and indoor units to the TB2 terminals 1 and 2 on
the PCB1. As for the transmission wires between outdoor units in the same refrigerant cycle, connect
them to the TB2 terminals 3 and 4 on the PCB1.
(3) Tighten screws for the terminal block according to the following table.
< Required Tightening Torque >
Size Tightening Torque
M3.5 0.7 to 1.1 N-m
M4 1.0 to 1.3 N-m
M5 2.0 to 2.4 N-m
M6 4.0 to 5.0 N-m
M8 9.0 to 11.0 N-m
M10 18.0 to 23.0 N-m

60 FAN-2207 201709

FAN-2209 201709 2-67


OUTDOOR UNIT

(1) Detail of Electrical Box Terminal


< 460V 60Hz > < 380V/60Hz >
Terminal Block for
Screw (M5 or M6) Power Source (TB1)
Terminal Block for
Power Supply Wiring (TB1)

Earth Terminal
(Connect
Attach securely cable.)
Attach insulation sleeve.
insulation sleeve.
Earth Wire
Ground Wiring Terminal
(Connect cable securely) Rubber Bush
Ground Wiring Cable Clamp
Cable Band (Accessory)

< 220V/60Hz >


Screw (M8) Terminal Block for
Power Source (TB1)
Electrical Box

(1) Terminal Block (5) Transition Wiring Outlet


for Power Source (Rubber Bush) Earth Terminal
(Connect
securely cable.)
Printed Circuit Board Attach
(PCB1) insulation
(5) Power Source Wiring sleeve.
Outlet (Rubber Bush) TB1
TB2 Rubber Bush Earth Wire
(2) Terminal Block Cable Clamp
for Control Circuit (Accessory)
Not used
Fix the control wiring Power Source Wiring
using a clamp.

Control Wiring
(2) Detail of Terminal Block for Control Circuit
Power Source Wiring
Screw (M3.5) PCB1 Terminal Block
for Control Circuit

Outdoor to Outdoor Terminal


Cord Clamp (Communication wiring between
(for fixing power outdoor units used in combination.)
source wiring) (5) Control Wiring Outlet H-LINK Terminal
(Rubber Bush) (Communication wiring between the
Cord Clamp (Accessory) outdoor unit and indoor unit, or
NOTE: between the outdoor unit and outdoor
Fix by accessory screw (for fixing control wiring). unit of other refrigerant system.)

This terminal is used only for combination outdoor units (26-54HP)


and not used for single units (8-24HP).

(4) Details of Piping Cover Wiring Outlet


(3) Details of Bottom Base Wiring Outlet For Power Source Wiring (Unit: mm)
(φ65 Knockout Hole)
(Unit: mm)

For Power Source Wiring For Control Wiring


(φ65 Knockout Hole) (φ33 Knockout Hole)
For Transition Wiring
(φ55 Knockout Hole)
For Transition Wiring NOTES:
(φ55 Knockout Hole) 1. Install accessory rubber bushes
to the wiring outlets. NOTES:
2. Seal hermetically the end of conduit 1. Install accessory rubber bushes to the wiring outlets.
For Control Wiring pipe by using putty, etc. 2. Seal hermetically the end of conduit pipe by using putty, etc.
(φ33 Knockout Hole) (for water protection) (for water protection)

(5) Details of Wiring Outlets inside the Electrical Box (Rubber Bush Section)
Rubber Bush (Wiring Outlet)
Using a cutter knife, cut
an X in the rubber bush
Correct Incorrect on site as shown below. Make sure that the power source wiring
passes through the center of the rubber bush.
Correct Incorrect
Snow or water
may enter.

Rubber Bush
Rubber Bush
Electrical Box Rubber
(Metal) Make sure that the rubber bush Bush If the power source wiring does not pass through
is in place. properly, snow or water may enter in the unit.

FAN-2207 201709 61

2-68 FAN-2209 201709


OUTDOOR UNIT

Be sure to note the following points to run the cables under the unit using conduit tube.
(The pipe cover needs to be removed before performing piping and wiring works.)

NOTES:
1. Do not run the power supply wiring and transmission wiring through the same conduit tube.
Moreover, keep at least 5cm between the power supply wiring and transmission wiring.
2. Pull out each wiring from each corresponding knockout hole. Cut can “X” in rubber bush (accessory)
and securely attach it to the knockout hole for cable protection.
Check that the rubber bush is surely attached.
3. Attach the pipe cover to prevent rats or other small animals from entering the unit.
4. Prevent the wirings from touching or rub against the refrigerant pipes, plate edges and electrical parts
inside the unit.
5. When the power source cable (cabtyre cable) whose size exceeds 38mm2 is used, peel the sheath part
of the cable put into the unit and run it. At this time, do not damage the coated insulating coated part.
6. Completely seal the end of conduit tube with sealing materials to prevent the rain from entering the
conduit tube.
7. Make a drain hole at the lowest part of the conduit tube.

Control Wiring Liquid Pipe


Transition Wiring High/Low Pressure Gas Pipe
Power Source Low Pressure Gas Pipe
Tightly secure the power source wiring using Wiring
a cord clamp inside the unit.

NOTE
Fix the rubber bushes with adhesive when conduit
Cover gaps with packings (field-supplied).
tubes to the outdoor unit are not used. Install accessory rubber bushes to the wiring outlets.

62 FAN-2207 201709

FAN-2209 201709 2-69


OUTDOOR UNIT

7.4 Electrical Wiring Connection of Indoor Unit, Outdoor Unit


(1) Connect a power supply wiring to each outdoor unit. Connect an ELB, fuse and main switch (S) to
each outdoor unit.
(2) Connect a power supply wiring to each indoor unit group connected to the same outdoor unit.
(Max. capacity of one indoor unit group is 26HP.)
Connect an ELB, fuse and main switch (S) to each indoor unit group.
(3) Connect the transmission wiring between indoor units and outdoor units, as shown in Fig. 7.1.
(4) Connect the transmission wiring in the same refrigerant cycle unit. (In the case that the refrigerant
piping of indoor unit is connected to the outdoor unit, also connect the transmission wiring to the same
indoor unit.) Connecting the refrigerant piping and transmission wiring to the different refrigerant cycle
systems may lead to malfunction.
(5) Use 2-Core lead wires such as shielded twist pair cable for the transmission wiring.
(Do not use 3-Core or over.)
(6) Use the same kind of cables in the same H-LINK system.
(7) The transmission wiring is required to be separated from the power supply wiring when installed
parallel to the power supply wiring.
Keep at least 5cm between the transmission wiring and the power supply wiring, and also min. 1.5m
between the transmission wiring and power supply wiring for other electrical device. If the above is
not secured, put the power supply wiring into the metal conduit tube to separate it from other wirings.
Make sure to ground the end of the power supply wiring.
(8) Connect the following transmission wiring to the terminals 1 and 2 of TB2 in the outdoor unit A (main
unit).
• between outdoor unit and indoor unit
• between outdoor unit and outdoor unit in other refrigerant cycles
(9) Do not connect the power supply wiring to the terminal block for transmission wiring (TB2).
All the printed circuit boards in the same refrigerant cycle will be damaged.
(10) Connect the earth wire to the outdoor/indoor units. The earth wiring work under the condition of 100W
(max.) ground resistance must be performed by a qualified person.
(11) Connect the transition wiring between outdoor units in the same refrigerant cycle to the terminals 3 and
4 on the terminal block (TB2).

• Transmission Wiring
Refrigerant Group 1 (Heat Pump System) Refrigerant Group 2 (Heat Recovery System)

Outdoor Unit Outdoor Unit Outdoor Unit Outdoor Unit


(Main) (Sub) (Main) (Sub)
TB1 TB2 TB1 TB2 TB1 TB2 TB1 TB2
L 1 L2 L3 N 1 2 3 4 L1 L2 L3 N 1 2 3 4 L1 L2 L3 N 1 2 3 4 L1 L 2 L 3 N 1 2 3 4

Transmission Wire
for Main ~ Sub
Transmission Wire
for H-LINK System CH-Box No.1 CH-Box No.2
TB1 TB2 TB1 TB2
L1 L N 1 2 3 4
2
L1 L N 1 2 3 4
2

2 1 B A N L 2 L1 2 1 B A N L2 L1 2 1 B A N L2 L1 2 1 B A N L2 L1 2 1 B A N L2 L1 2 1 B A N L2 L1
TB2 TB1 TB2 TB1 TB2 TB1 TB2 TB1 TB2 TB1 TB2 TB1
Unit No. 0 Unit No.1 Unit No. 2 Unit No. 0 Unit No.1 Unit No. 2
Indoor Unit Indoor Unit Indoor Unit Indoor Unit Indoor Unit Indoor Unit

Transmisson Wire for CH-Box ~ Indoor Unit

NOTES:
1. For the combination units (26-54HP), DSW settings of Main and Sub are required.
2. Alarm occurs if the transmission wires between main outdoor unit and sub outdoor units are connected to
the terminals 1 and 2 for H-LINK system.
3. In case that alarm is indicated on the LCD of Main outdoor unit, follow the "7-segment" indication of the Main
outdoor unit for checking.
4. Perform function setting at Main outdoor unit.
5. Maximum number of refrigerant groups with one central controller is 64 (for H-LINK II).
Maximum number of indoor units to be connected is 160 (for H-LINK II).

FAN-2207 201709 63

2-70 FAN-2209 201709


OUTDOOR UNIT

< 380V/60Hz >

Outdoor Unit A (Main) Outdoor Unit B (Sub)

TB1 TB2 TB1 TB2


L1 L2 L3 N 1 2 3 4 L1 L2 L3 N 1 2 3 4
TB : Terminal Block
PCB : Printed Circuit Board
Earth Earth : Field Wiring
: Transmission Line (Shielded Twist Pair Cable)
Main Switch DC5V (Non-Pole Transmission H-LINK System)
: Field Supplied
FUSE : Optional Accessory

ELB ELB
Main
Switch
3N CH-Box 1 CH-Box 2 CH-Box 3
380V/60Hz FUSE
TB1 TB2 TB1 TB2 TB1 TB2
L1 N 1 2 3 4 L1 N 1 2 3 4 L1 N 1 2 3 4
ELB ELB

3N
380V/60Hz
Distribution Box
or Pull Box

Main Distribution Box Distribution Box Distribution Box Distribution Box


Switch or Pull Box or Pull Box or Pull Box or Pull Box

FUSE L1 L2 N L1 L2 N L1 L2 N L1 L2 N L1 L2 N
TB1 TB1 TB1 TB1 TB1
ELB ELB No. 0 No. 1 No. 2 No. 3 No. 4
Indoor Unit Indoor Unit Indoor Unit Indoor Unit Indoor Unit
1 TB2 TB2 TB2 TB2 TB2
220-240V/50Hz A B 1 2 A B 1 2 A B 1 2 A B 1 2 A B 1 2
220V/60Hz

Controller Controller Controller Controller


Cable Wired Cable Wired Wired Cable Wired Cable Wired
(Shielded Controller (Shielded Controller Controller (Shielded Controller (Shielded Controller
Twist Twist Twist Pair Twist
Pair Cable) Pair Cable) Cable) Pair Cable)

Indoor Unit Group For Cooling Operation Only

< 460V/60Hz, 220V/60Hz >

Outdoor Unit A (Main) Outdoor Unit B (Sub)

TB1 TB1 TB2 TB1 TB2


L1 L2 L3 R S T 1 2 3 4 R S T 1 2 3 4
TB : Terminal Block
PCB : Printed Circuit Board
For 460V For 220V Earth For 220V
Earth : Field Wiring
: Transmission Line (Shielded Twist Pair Cable)
Main Switch DC5V (Non-Pole Transmission H-LINK System)
: Field Supplied
FUSE : Optional Accessory

ELB ELB
Main
Switch For Mexico model For Mexico model
3 Except for Mexico model
CH-Box 1 CH-Box 2 CH-Box 3
220V/60Hz FUSE
TB1 TB2 TB1 TB2 TB1 TB2 TB1
460V/60Hz R S R S R S R S
L1 L2 1 2 3 4 L1 L2 1 2 3 4 L1 L2 1 2 3 4 L1 N
ELB ELB

3
220V/60Hz
460V/60Hz Distribution Box
or Pull Box

Distribution Box Distribution Box Distribution Box Distribution Box


Main or Pull Box or Pull Box or Pull Box or Pull Box
Switch

FUSE R S Mp R S Mp R S Mp R S Mp R S Mp
TB1 TB1 TB1 TB1 TB1
ELB ELB No. 0 No. 1 No. 2 No. 3 No. 4
Indoor Unit Indoor Unit Indoor Unit Indoor Unit Indoor Unit
TB2 TB2 TB2 TB2 TB2
1 A B 1 2 A B 1 2 A B 1 2 A B 1 2 A B 1 2
220V/60Hz

Controller Controller Controller


Controller
Cable Cable Wired Cable Wired
Wired Wired Wired Cable
(Shielded (Shielded Controller (Shielded Controller
Controller Controller Controller (Shielded
Twist Pair Twist Pair Twist Pair
Twist Pair
Cable) Cable) Cable)
Cable)
Indoor Unit Group For Cooling Operation Only

Fig. 7.1 Instruction for Electrical Wiring Connection


64 FAN-2207 201709

FAN-2209 201709 2-71


OUTDOOR UNIT

7.5 Accessing Switches on Printed Circuit Board


It is not required to open the complete electrical box to access the push switches on the printed circuit board
and read out the 7-segment display(s).
To access you can remove the front cover. Now you can open the access door of the electrical box front
cover (see figure). You can see the push switches and the 7-segment displays and Dip switches.

Printed Circuit Board Electrical Box Front Cover

7-Segment
(7SEG)
Screw

Screw

Dip Switch (DSW)


Access Door Rotary Switch (RSW)
Push Switch (PSW)

Operate the switches and push switches with an insulated stick


(such as a closed ball-point pen) to avoid touching of live parts.

Make sure to re-attach the access door into the electrical box cover and to close the front cover after the job
is finished.

NOTICE
● Shut the access door after performing the service work, otherwise a malfunction may occur due to water
or foreign materials entering.
● Operate the switches and push switches with an insulated stick (such as a closed ball-point pen) to avoid
electrical shocking.

FAN-2207 201709 65

2-72 FAN-2209 201709


OUTDOOR UNIT

7.6 Dip Switch Setting of Outdoor Unit


TURN OFF all power sources before the setting.
Without turning OFF all power sources, the switches do not work and the setting are invalid.
(However, DSW4-No.1, 2, 4, 5, 6 and push switches can be operated while power source is ON.)
The mark “n” indicates the position of dip switches. Set the dip switches according to the Fig.7.2.

NOTE
l By using switch DSW4, the unit is started 10 to 20 seconds after the switch
is operated.
l For service and maintenance, number this outdoor unit to distinguish it
from the other outdoor units.
And write down the number in the box right.

Arrangement of Dip Switches (PCB1) DSW1 (PCB1) Ref. Cycle No. Setting DSW3 (PCB1) Function Setting
Display Setting is required. No setting is required.
(7SEG)
Setting Before Shipment Setting Before Shipment Setting Before Shipment
except Middle East only Middle East
SEG2 SEG1 Setting Position
ON ON
RSW1
PSW2 DSW1 0 1 2 3 4 1 2 3 4
DSW4 DSW7 9 1
ON

23
78
PSW5 PSW1 PSW3
DSW2 DSW3 4 56 DSW4 (PCB1) Test Run and Service Setting
Enter
1 2 3 4 5 6
PSW4 DSW5 DSW6 Setting is required. For Test Run, Function Setting
Tens Digit Last Digit
DSW8 Setting Before and External Input/Output Setting
DSW1 Set the unit number of outdoor unit at each Shipment
RSW1
refrigerant cycle. ON
DSW10 (Setting before shipment is unit 0.)

1 2 3 4 5 6
DSW2 (PCB1) Capacity Setting
Setting Item Pin No.
No setting is required. Test Cooling Operation 1
Test Heating Operation 1, 2
< Standard Type >
Compressor Forced Stop 4
Capacity 8HP 10HP 12HP 14HP 16HP
Function Setting 4, 5
ON ON ON ON ON External Input/Output Setting 4, 6
DSW2
Setting
1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6 DSW5 (PCB1) Emergency Operation
Capacity 18HP 20HP 22HP 24HP Turn ON the dip switch
No setting is required.
when use the below
ON ON ON ON Setting Before
DSW2 functions.
Setting Shipment
1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6
Setting Item Pin No.
ON Except No.1 Comp.
1
(MC1) Operation
< High Efficiency Type > 1 2 3 4 5 6 Except No.2 Comp.
Capacity 5HP 6HP 8HP 10HP 2
(MC2) Operation

ON ON ON ON
DSW2
Setting DSW8 (PCB1) High Static Pressure Mode
Setting
1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6

Capacity 12HP 14HP 16HP 18HP Setting is required. Turn ON the dip switch
when use the below functions.
ON ON ON ON Setting Before
DSW2
Shipment Setting Item Pin No.
Setting
1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6 ON HSP Setting: 30Pa 1
HSP Setting: 60Pa 2
1 2 3 HSP Setting: 80Pa 1, 2
DSW6 (PCB1) Outdoor Unit No. Setting/Function Setting

Setting is required.
IMPORTANT NOTICE
Combination Setting
Unit A Unit B Unit C Unit D When adopting the air outlet duct
Single Setting (field-supplied), make sure to set DSW8.
(Setting Before Shipment) (No.0 Unit) (No.1 Unit) (No.2 Unit) (No.3 Unit)

ON ON ON ON ON
DSW10 (PCB1) Transmission Setting
1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 Set DSW10-1 correctly
Setting is required.
for end resistance cancellation.
Turn ON the dip switch when use the below functions. Setting Before
Setting Item Pin No.
Shipment
Setting Item Pin No. IMPORTANT NOTICE End Resistance Setting *1 1
ON
The outdoor unit is not single, the combination setting Fuse Recovery *2 2
Outdoor Unit No. Setting 1, 2, 3
is necessary. Be sure to do this setting.
1 2 *1: Turn OFF No.1 pin for all of
Cooling Operation Under the outdoor units in the same H-LINK
Make sure to apply Snow Protection Hood system except one outdoor unit.
Low Load Operation 4
(Optional Parts). *2: If the fuse (EF1) is melted,
(Low Ambient Setting)
set No.2 pin to ON for recovery.

DSW7 (PCB1) Power Supply Voltage and System Setting INV No. Setting
DSW101 (INV1, 2) /Service Setting
No setting is required.
No setting is required.
220V Unit: 220V Setting Before Shipment
380V Unit: 380V Setting Before Shipment INV1 INV2
400V Unit: 400V Setting Before Shipment
Setting Before Shipment Setting Before Shipment
460V Unit: 460V Setting Before Shipment
ON ON
Setting is required.
380-415V Unit: 415V Setting Before Shipment 1 2 3 4 5 6 1 2 3 4 5 6

Power Supply Voltage and System Setting Turn ON the dip switch when
use the below functions.
220V 380V 400V 415V 460V
Setting Item Pin No.
ON ON ON ON ON
Heat Pump Cancellation of Current Detection 1
(2 Pipes)
1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4
IMPORTANT NOTICE
ON ON ON ON ON
Heat Recovery If Cancellation of Current Detection is set,
(3 Pipes) make sure to return the setting, after
1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 service works.

Fig. 7.2 DSW Setting


66 FAN-2207 201709

FAN-2209 201709 2-73


OUTDOOR UNIT

● Setting for Transmitting


It is required to set the outdoor unit No., refrigerant cycle No. and end terminal resistance for
this H-LINK system.
● Setting of Outdoor Unit No.
In case of the combination of base unit, set DSW6 as shown below.
Combination of Base Unit
Base Unit
(Before Shipment) Unit A Unit B Unit C
(No.0) (No.1) (No.2)

ON ON ON ON
OFF OFF OFF OFF
1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4

● Setting of Refrigerant Cycle No.


In the same refrigerant cycle, set the same refrigerant cycle No. for the outdoor unit and the indoor units
as shown below.
Setting outdoor unit refrigerant cycle No. is required only for the main unit.
The sub unit settings are not required.
As for setting indoor unit refrigerant cycle No., set RSW2 and DSW5 on the indoor unit PCB.

Setting Switch Ex.: In Case of Setting Refrigerant Cycle No. 25


10 digit 1 digit
Setting Position 901
ON

23
78
ON OFF
OFF 901 Set by inserting 456
1 2 3 4 5 6 slotted screwdriver 1 2 3 4 5 6
23
78

456 into the groove.


Turn ON No. 2 pin. Set Dial No.5.
Outdoor Unit DSW1 RSW1
DSW and RSW setting before shipment is 0.
Indoor Unit
DSW5 RSW2 Maximum in setting refrigerant cycle No. is 63.
(H-LINK II)

< Setting Example > No setting is required. No setting is required.

Sub Unit Sub Unit Main Unit


ON ON ON
DSW1: OFF
1 2 3 4 5 6
DSW1: OFF
1 2 3 4 5 6
DSW1: OFF
1 2 3 4 5 6

901 901 901


RSW1: RSW1: RSW1:
23

23

23
78

78

78

456 456 456 Ref. Cycle No. 25

DSW6: DSW6: DSW6:


ON ON ON
OFF OFF OFF
1 2 3 4 1 2 3 4 1 2 3 4

Setting of Setting of Setting of Main Unit (Unit A)


Sub Unit (Unit C) Sub Unit (Unit B) H-LINK II (Factory Setting)
to the Indoor Units

Set the refrigerant cycle No.


not to duplicate no. with the other outdoor units.

SET FREE
Series
Refrigerant Cycle for UTOPIA Series Maximum Number of Connectable
Outdoor Unit
This Outdoor Unit Outdoor Unit Outdoor Units and Indoor Units
(for H-LINK II)
Transmission Line Outdoor Unit 64
(No Polarity) Indoor Unit 160
H-LINK or H-LINK II
Set to the same refrigerant NOTE:
cycle No. For installing the outdoor unit
and the indoor unit on the same
transmission wire, which cannot
Indoor be used for H-LINK II, maximum
Unit number of connectable indoor units
Wired Controller Centralized Controller is 128.

FAN-2207 201709 67

2-74 FAN-2209 201709


OUTDOOR UNIT

● DSW7 Setting for Rated Voltage


DSW7 is used for setting of rated voltage for the outdoor unit as shown right.
When the site power source voltage is different from factory setting, DSW7 setting is required.
NOTE:
The same voltage setting is required to the main unit and sub unit(s).

220V Unit: 220V Setting Before Shipment


Voltage 220V 380V 460V
380V Unit: 380V Setting Before Shipment
460V Unit: 460V Setting Before Shipment
ON ON ON
DSW7 Setting OFF OFF OFF
1 2 3 4 1 2 3 4 1 2 3 4

● Setting of End Terminal Resistance


Setting of End Terminal Resistance
Before shipment, No. 1 pin of DSW10 (for the setting of end terminal DSW10
resistance) is in the “ON” position. Before Shipment Cancellation
In the case of one refrigerant cycle in the same H-LINK or H-LINK II, ON ON
set all No. 1 pins of DSW10 in the “OFF” position except the main
1 2 OFF 1 2 OFF
outdoor unit A.

In the case of one refrigerant cycle in the same H-LINK or H-LINK II, set all No. 1 pins of DSW10 in the “OFF”
position except the main outdoor unit A.

Set the end terminal.


Outdoor Unit
(Unit Combination)

DSW10 DSW10 DSW10

12 12 12

Unit A Unit B Unit C


(Main) (Sub) (Sub)

Cancel the end terminal setting.


Transmission Line
(No Polarity)
H-LINK or H-LINK II

Indoor
Unit

In the case of more than one refrigerant cycles in the same H-LINK or H-LINK II, set all No. 1 pins of
DSW10 in the “OFF” position except the main outdoor unit A.

Outdoor unit being


set end terminal Cancel the end terminal.
Cancel the end terminal. Cancel the end terminal.

Outdoor Unit Outdoor Unit Outdoor Unit Outdoor Unit


(Base Unit) (Unit Combination) Set the end terminal. (Unit Combination) (Base Unit)

DSW10 DSW10 DSW10 DSW10 DSW10 DSW10 DSW10

12 12 12 12 12 12 12

Unit A Unit B Unit C Unit A Unit B


(Main) (Sub) (Sub) (Main) (Sub)

Transmission Line
(No Polarity) Cancel the end terminal setting.
H-LINK or H-LINK II

Indoor Indoor Indoor Indoor


Unit Unit Unit Unit

Wired Controller

68 FAN-2207 201709

FAN-2209 201709 2-75


OUTDOOR UNIT

• Function Setting

External Input/Output and Function Setting


Make sure to perform external input/output and function setting while the outdoor unit is stopped.
It cannot be set while the outdoor unit is operating or check mode.
[ External Input/Output Setting ] [ Function Setting ]
Start of Setting Start of Setting
Turn ON DSW4-No.4. Turn ON DSW4-No.4.
Turn ON DSW4-No.6. Turn ON DSW4-No.5.
2 [ Function Setting ]
For the setting mode, refer to 1 below. For the setting mode, refer to 2 below.
NOTE: By pressing the push-switches PSW3 ( ) and PSW5 ( ),
Exit Setting Mode Exit Setting Mode Release “Menu Mode” after the setting can be changed.
Turn OFF DSW4-No.6 during indicated Turn OFF DSW4-No.5 during indicated the setting is completed. PSW4 ( ): forward, PSW2 ( ): backward
External Input/Output Setting Mode. Function Setting Mode. Otherwise, the air conditioner Refer to the Service Manual for more details.
Turn OFF DSW4-No.4. Turn OFF DSW4-No.4. may not operate appropriately. < Example >
Fill out the selected function setting No.
After setting, confirm DSW4 setting is same as setting before shipment. in the space of the table as shown.

Item SEG2 SEG1 SET Item SEG2 SEG1 SET


1 [ External Input/Output Setting ]
Circulator Function at
1 25 Not Prepared
Heating Thermo-OFF
By pressing the push-switches PSW3 ( ) and PSW5 ( ),
the function No. can be selected. 2
Night-Shift
26
Crankcase Heater Control
PSW4 ( ): forward, PSW2 ( ): backward (Low Noise) during Stoppage

< Example > 3


Cancellation of Outdoor
27
Indoor Fan Hot Start Period
Fill out the selected function setting No. Ambient Temperature Limit Setting
in the space of the table as shown. Defrost for Cold Area
Intermittent Operation
4 (Change of 28
of Outdoor Fan Motor
Defrost Condition)
Item SEG2 SEG1 SET
SLo (Fan Speed) Indoor Expansion Valve
Input Setting 1 5
1 Defrost Setting Control Target Value
CN17 [1-2 pin] 29 for Cooling
Cancellation of (Only for
Input Setting 2 6
2 Outdoor Unit Hot Start 4-Way Cassette Type)
CN17 [2-3 pin]
Indoor Expansion Valve
Input Setting 3 7 Priority Capacity Mode 30 Opening Lower Limit during
3 Heating SW-OFF
CN18 [1-2 pin]
Minimum Evaporating
8 Temperature Setting 31 Not Prepared
Output Setting 1
4 for Cooling
CN16 [1-2 pin] Compressor Frequency Forced Defrosting after
9 Control Target Value 32 Enforced Stoppage during
Output Setting 2
5 for Heating Defrosting Cycle
CN16 [1-3 pin] Indoor Expansion Valve
(Setting Before Shipment) 10 Control Target Value 33 Not Prepared
for Cooling
Indoor Expansion Valve
Before shipping, the input/output function settings are specified 11 Control Target Value 34 Not Prepared
to each input/output terminal according to above table. for Heating
The details of function No. and external input/output settings Indoor Expansion Valve
are as shown below. 12 Opening during Heating 35 Not Prepared
Operation Stoppage
Indoor Expansion Valve
Permit Indoor Fan Operation
13 Opening during Heating 36
Setting of External Input and Output Function Thermo-OFF
during Forced Stoppage
Function Indoor Expansion Valve
Input Output
No. 14 Initial Opening during 37 Not Prepared
1 Fixing Heating Operation Mode Operation Signal Heating Thermo-ON
2 Fixing Cooling Operation Mode Alarm Signal Indoor Expansion Valve
15 38 Not Prepared
Initial Opening for Cooling
3 Demand Stoppage Compressor ON Signal
4 Outdoor Fan Motor Start/Stop Defrost Signal Outdoor Expansion Valve
16 39 Not Prepared
5 Forced Stoppage - Initial Opening for Heating
6 Demand Current Control 40% -
17 Low Noise Setting 40 Not Prepared
7 Demand Current Control 60% -
8 Demand Current Control 70% -
9 Demand Current Control 80% - 18 Demand Function Setting 41 Not Prepared
10 Demand Current Control 100% -
11 Low Noise Setting 1 - 19 Wave Function Setting 42 Not Prepared
12 Low Noise Setting 2 - Protection of Decrease
13 Low Noise Setting 3 - 20 in Outlet Temperature 43 Not Prepared
External Abnormality Detection for Cooling
14 -
Setting Outlet Temperature Control
21 44 Not Prepared
0 No Setting No Setting (DOAS)

The same input/output function setting cannot be set to different 22


Adjustment of Fan Rotation
45 Not Prepared
input/output terminals. (for multiple installation)
If set, a setting of larger function number becomes invalid.
Example: When setting of input 1 and input 2 are same, 23 Not Prepared 46 Not Prepared
input 2 will be invalid.
Thermo-OFF Setting
24 for Outdoor Unit After 47 Not Prepared
Function No.14 is valid only when applied to Input Setting 3. Defrosting Operation

FAN-2207 201709 69

2-76 FAN-2209 201709


OUTDOOR UNIT

8. Additional Refrigerant Charge


8.1 Air-Tight Test
(1) Check to ensure that spindles of the stop valves for gas and liquid pipes are closed completely before
air-tight test.
(2) The refrigerant used for this outdoor unit is R410A. Use the manifold gauge and the charging hose for
exclusive use of R410A.
< Tightening Check of Stop Valves >
After connecting the pipe, remove the caps of stop valves for gas and liquid. Tighten the open-close
spindle in the closing direction according to the following tightening torque.
● Caution for Operation of Stop Valves
(a) Remove the stop valve caps before performing the air-tight test after connecting the refrigerant
piping. Tighten the spindle (valve) in clockwise direction according to the following tightening torque.
(b) Perform the work after warming the spindle part with a dryer etc. when controlling the stop valve in a
cold area.
(O-ring of the spindle part will harden at the low temperature and the refrigerant leakage may occur.)
(c) Do not apply an excessive force after fully opening the spindle. (Tightening Torque: < 5.0N-m)
(The back seat is not provided.)
(d) When each valve is opened, remove tags “Close” (Accessories) and attach tags “Open” instead.
(e) Tighten securely the caps according to the following tightening torque after each spindle valve is
opened.

Stop Valves for Gas Pipe Check Joint


(High/Low Pressure) Only the charging
Stop Valve for Gas Pipe Cap hose for R410A
Do NOT put two (Low Pressure) can be connected.
wrenches here. Hexagonal Refrigerant
Wrench Pressure
Stop Valve for To open
Liquid Pipe or close Spindle Valve
the spindle O-ring Counterclockwise...Open
Position both (Rubber) Clockwise...............Close
wrenches here. Flare Nut Closed before Shipment

Tightening Torque (N-m) Hexagonal


Wrench Size
Outdoor Unit Spindle (Valve) Flare Nut Cap Check Joint (mm)
(Base Unit) Low High/Low
Liquid Gas Liquid Gas Liquid Gas Liquid
Pressure Pressure Liquid
Valve Valve Valve Valve Valve Valve Valve
Gas Valve Gas Valve
8 - 12HP 18.0 - 22.0 33.0 - 42.0
7.0 - 9.0 33.0 - 42.0 4
14 - 18HP 18.0 - 22.0 50.0 - 62.0 49.0 - 58.0 9.0 - 14.0 14.0 - 18.0 10
25.0 - 31.0
20 - 24HP 9.0 - 11.0 68.0 - 84.0 50.0 - 62.0 5

70 FAN-2207 201709

FAN-2209 201709 2-77


OUTDOOR UNIT

< Air-Tight Test Method >


(1) Connect the manifold gauge to the check joints of the liquid line and the gas line stop valves using
charging hoses with a vacuum pump or a nitrogen cylinder.
Perform the air-tight test.
Do not open the stop valves. Apply nitrogen gas pressure of 4.15MPa.
For checking gas leakage, use the leak detector or forming agent. If there is any leakage, fix the
leaking part.
(2) For checking gas leakage, do not use a forming agent which generates ammonia.
Additionally, do NOT use a household detergent as forming agent whose components are not clear.
The recommended forming agent for checking gas leakage is shown below.

Procedure
Recommended
Manufacturer
Completion of Applying Check of
Pass Forming Agent
Ref. Piping Nitrogen Gas Pressure Decrease
Yokogawa
Guproflex
Repairing of & CO.,Ltd
Leakage Part

Be sure to use Nitrogen Gas for air-tight test. If other gases such as oxygen gas, acetylene gas or
fluorocarbon gas are accidentally used, it may cause an explosion or gas intoxication.

< Insulation Work >


(1) Securely insulate gas piping side and liquid piping side individually.
Make sure to insulate the union flare nut for the piping connection as well.
(2) Mount the piping cover equipped with the outdoor unit after connecting the pipe.
Completely seal the penetration part at the bottom of the pipes with insulation in order to prevent rain
water from entering the conduit.
(3) Cover the gap between the piping cover and pipes with a packing (field-supplied) after the insulation
work is completed.
NOTICE:
If the gap is not covered, the unit may be damaged if snow, rain water or animals enter the unit.

● For Piping from Bottom Base ● For Piping from Front or Rear Side Piping Cover
Control Wiring Liquid Pipe Cover gaps with packings (field-supplied).
Transition Wiring High/Low Pressure Gas Pipe Install accessory rubber bushes to the wiring outlets.
Power Source Low Pressure Gas Pipe Piping Control Wiring
Wiring Cover
Transition Wiring

Low Pressure
Gas Pipe
Power Source
Cover gaps with packings (field-supplied). Wiring
Install accessory rubber bushes to the wiring outlets. Liquid High/Low Pressure
Pipe Gas Pipe

FAN-2207 201709 71

2-78 FAN-2209 201709


OUTDOOR UNIT

8.2 Vacuuming

< Connecting >


Connect a manifold gauge, vacuum gauge and vacuum pump to the check joints (Gas Stop Valve and
Liquid Stop Valve).

< Basic Method >


If the penetration of moisture is suspected, perform “Triple Evacuation Method” that is described in the next
paragraph.
(1) Vacuum until the pressure reaches 500 microns (0.5 mmHg) or Lower for two hours.
(2) After vacuum pumping work, stop the vacuum pumping and leave the gauge for one hour.
(3) Check to ensure that the pressure in the vacuum gauge does not increase.
(4) Tighten the caps of check joint according to the specified torque after the vacuum drying work.
(5) If the pressure inside the gauge does not reach 500 microns, it is considered that there is gas leakage.
(6) Check for any gas leakage once again.
(7) If no leakage exists, it might be moisture remains inside the pipes.
Perform “Triple Evacuation Method”.

< Triple Evacuation Method >


According to the following [Step 1] [Step 2] [Step 3] in order, conduct vacuum drying work.
[Step 1]
(1) Vacuum until the pressure reaches 2000 microns (2.0 mmHg).
(2) Pressurize with nitrogen up to 0.3 MPaG (50 PSIG) for 15 minutes.
(3) Release pressure to atmosphere level as less than 0.03 MPaG (5 PSIG).

[Step 2]
(1) Vacuum until the pressure reaches 1000 microns (1.0 mmHg).
(2) Pressurize with nitrogen up to 0.3 MPaG (50 PSIG) for 15 minutes.
(3) Release pressure to atmosphere level as less than 0.03 MPaG (5 PSIG).

[Step 3]
(1) Vacuum until the pressure reaches 500 microns (0.5 mmHg).
(2) Stop vacuum pump.
(3) Check that the vacuum 500 microns (0.5 mmHg) can maintain for one hour.

NOTICE
1. If tool or measuring instruments come into contact with the refrigerant, use the tools or the measuring
instruments exclusively for R410A.
2. Do not perform vacuuming pumping work with valves of the outdoor units open.
Otherwise, the refrigerant charged before shipment may leak and it may result in failure.
If moisture remains inside the pipes, the compressor may be damaged.

72 FAN-2207 201709

FAN-2209 201709 2-79


OUTDOOR UNIT

8.3 Additional Refrigerant Charge Calculation


Table 8.1 Additional Refrigerant Charge Calculation
Although refrigerant has been charged into this unit in advance, additional refrigerant charge is required according
to piping length.
Determine the additional refrigerant quantity according to the following procedure, and charge the system with it.
Record the additional refrigerant quantity to facilitate maintenance and servicing activities thereafter.
(1) Calculating Method of Additional Refrigerant Charge (W kg)
Additional
No. Symbol Contents
Ref. Charge
1 W1 Additional Refrigerant Charge Calculation for Liquid Piping (W1 kg)
Pipe Diameter (mm) Total Piping Length (m) Refrigerant Amount for 1m Pipe (kg/m) Additional Ref. Charge (kg)
φ28.58 × 0.67 =
φ25.4 × 0.52 =
φ22.2 × 0.36 =
φ19.05 × 0.26 =
φ15.88 × 0.17 =
φ12.7 × 0.11 =
φ9.52 × 0.056 =
φ6.35 × 0.024 =
Total Additional Ref. Charge For Liquid Piping =
NOTE:
In the case that the quantity calculated above is less than the minimum quantity indicated in the table below, adopt the quantity in the table
below as the additional refrigerant quantity for piping liquid, regardless of the piping length.
Outdoor Unit Capacity (HP) 8, 10 12 - 18 20 - 24 26 - 36 38 - 42 44 - 48 50 - 54 56 - 60 62 - 66 68 - 72 74 - 78 80 - 84 86 - 90 92 - 96
Minimum Additional Ref.
2.0 3.0 4.0 6.0 7.0 8.0 9.0 10.0 11.0 12.0 13.0 14.0 15.0 16.0
Charge of Base Unit (kg)
For combination of the units, adopt the total minimum quantity of each base unit as the minimum additional refrigerant quantity.
kg
2 W2 Additional Refrigerant Charge Calculation for Indoor Unit (W2 kg)
The additional refrigerant charge is required depending on the number of connected indoor units.
Select adequate refrigerant charge from the table below.
Maximum additional refrigerant charge must not exceed 6.0kg.
Additional Refrigerant Charge Quantity (kg)
Indoor Unit Capacity (HP) 0.4 - 1.0 1.5 - 6.0
Additional Ref. Charge (kg) 0.3 0.5

unit × 0.3kg/unit or 0.5kg/unit = kg < 6.0kg


kg
3 W3 Additional Refrigerant Charge Calculation for Indoor Unit (W3 kg)
Additional refrigerant charge is 1kg/unit of 8HP and 10HP indoor unit.
Additional refrigerant charge of less than 8HP indoor units is not needed.
8 and 10HP Total Indoor Unit Numbers Additional Ref. Charge
unit × 1.0kg/unit = kg
kg
4 W4 Additional Refrigerant Charge Quantity for Ratio of Indoor Unit Connection Capacity
(Indoor Unit Total Capacity/Outdoor Unit Capacity) (W4 kg)
Determine the ratio of indoor unit connection capacity.
Condition Additional Ref. Charge
• I.U. Capacity Ratio is less than 100%: 0.0kg
• I.U. Capacity Ratio is more than 100%: 0.5kg kg
5 W5 Depending on connection of outdoor unit model, additional refrigerant charge is required.
Select adequate refrigerant charge from the table below. (W5 kg)
Outdoor Unit Capacity (HP) 24, 38, 42, 46, 56, 60, 64, 68, 74, 78 48, 62, 66, 70, 80, 82, 84, 92 72, 86, 88, 90, 94 96
Additional Ref. Charge (kg) 1.0 2.0 3.0 4.0
kg
6 W6 Additional Refrigerant Charge Quantity for Each CH-Box (Multiple Branch Type) Connected (W6 kg)
If CH-Boxes (multiple branch type) are connected, additional refrigerant charge is required.
Select adequate refrigerant charge from the table below.
CH-Box Model JCH-AP04MSSX JCH-AP08MSSX JCH-AP12MSSX JCH-AP16MSSX
Additional Ref. Charge (kg) 0.1 0.2 0.3 0.4
kg
7 W Calculation of Additional Ref. Charge (W kg) = W1 + W2 + W3 + W4 + W5 +W6 kg

NOTES:
1. Some refrigerant charge calculations differ when installing Wall Type (RPK-FSXNSH3 Series) with the expansion
valve kit. Refer to the item “Additional Refrigerant Calculation for Wall Type (RPK-FSXNSH3 Series) with the
Expansion Valve Kit” .
2. Ensure that the total additional refrigerant charge quantity should not exceed the max. additional refrigerant charge
quantity shown below.
< Max. Additional Refrigerant Charge Quantity >
Outdoor Unit Capacity (HP) 8, 10 12 14 - 18 20, 22 24 26 - 54
Max. Additional Ref. Charge (kg) 28.0 36.0 40.0 51.0 52.0 63.0

FAN-2207 201709 73

2-80 FAN-2209 201709


OUTDOOR UNIT

(2) Charging Work


Charge the system with refrigerant R410A according to Item 8.4.
(3) Record of Additional Refrigerant Charge
Total refrigerant charge of this system is calculated in the following formula.
Total Ref. Charge = W + W0
Total Additional Ref. Charge: W kg
This System = + = kg
Total Ref. Charge: kg
Date of Ref. Charge Work: / /
< Ref. Charge Amount of O.U. Before Shipment (W0) kg >
Outdoor Unit
W0 Outdoor Unit Ref. Charge (kg)
(HP)
8 5.0
10 5.0
12 7.2
14 8.9
16 9.9
18 10.7
20 11.3
22 11.3
24 11.6
NOTE:
• W0 is outdoor unit ref. charge before shipment.
• In case of the combination of the base units, calculate the total ref. charge before shipment of the outdoor units to be
combined.

(4) Regarding the fluorocarbon, follow the specification label or refrigerant label attached to the product. After
the additional refrigerant charge, record the total refrigerant (= refrigerant before shipment + additional
refrigerant in the field) in the refrigerant label (*).
(*): In case of the combination of base units, record the total refrigerant in the main unit label.
NOTE:
When the refrigerant is recovered or charged because of repairing, operating or adjusting the unit, record the
refrigerant quantity again.

NOTICE
1. Emissions of the fluorocarbons without any reason are prohibited.
2. For disposal and maintenance of this product, collection of fluorocarbons is required.

74 FAN-2207 201709

FAN-2209 201709 2-81


OUTDOOR UNIT

8.4 Charging Work


(1) The additional refrigerant charge is required according to the total piping length. Refer to Table 8.1.
(2) After vacuum pumping work, check that the gas stop valve and liquid stop valve are fully closed.
Charge the additional refrigerant from the check joint of liquid stop valve (acceptable error must be
within 0.5 kg).
(3) After the refrigerant has been charged, fully open the liquid stop valve and the gas stop valve.
NOTE:
The gas staying at O-ring or screw part may make sound when removing the cap of the spindle.
However, it is not gas leakage.
(4) If it is impossible to charge the specified quantity of refrigerant, follow the procedure below.
(a) Fully open the stop valve for the gas line.

Do not apply an excessive force to the spindle valve after fully opening the spindle. Otherwise,
the spindle valve flies out due to refrigerant pressure. At the test run, open fully the spindle valve,
otherwise, the devices will be damaged. (It is closed before shipment.)

< Caution for Opening Stop Valve >


1. Do not apply an excessive force after fully opening the spindle. (Tightening Torque: < 5.0N-m)
(The back seat is not provided.)
2. When the valve is opened, remove the tags “Close” (Accessories) and attach the tags “Open”
(Accessories) instead.
3. Tighten securely the caps according to the tightening torque (Item 8.1-(2)-(e)) after each spindle
valve is opened.
Check Joint Hexagonal Wrench Size (mm)
(Only the charging hose for
Cap R410A can be connected.) Outdoor Unit (HP) Gas Valve Liquid Valve
8 - 12HP
4
14 - 18HP 10
Hexagonal Wrench Refrigerant Pressure 20 - 24HP 5
(To open or close spindle valve) Spindle Valve
Counterclockwise...Open
O-ring Clockwise...............Close
(Rubber) Closed before shipment

(b) Operate the compressor in the cooling mode and charge the additional refrigerant from the check
joint of the liquid stop valve (acceptable error must be within 0.5 kg). At this time, keep the liquid
stop valve slightly opened
(c) After the refrigerant is charged, fully open the liquid stop valve and the gas stop valve.
(d) Calculate securely the additional refrigerant quantity for charging. If the quantity of additional
refrigerant is not correct, it may cause compressor failure. The additional refrigerant must be
charged in a liquid condition.
(e) Refrigerant charge from check joint of gas stop valve may lead to compressor failure. Be sure to
charge refrigerant from the check joint of liquid stop valve.

FAN-2207 201709 75

2-82 FAN-2209 201709


OUTDOOR UNIT

Manifold
Outdoor Unit C Outdoor Unit B Outdoor Unit A Gauge Nitrogen Tank
Stop Valve Stop Valve Stop Valve (for Nitrogen Blow during Brazing
(for High/Low (for High/Low (for High/Low and Airtight Test)
Pressure Gas) Pressure Gas) Pressure Gas)
Stop Valve Stop Valve Stop Valve
(for Low (for Low (for Low
Pressure Gas) Pressure Gas) Pressure Gas)

Siphon Refrigerant Cylinder


Vacuum Pump (R410A)
Low Pressure Gas Line Scale
High/Low Pressure Gas Line
Stop Valve Stop Valve Stop Valve
(for Liquid) (for Liquid) (for Liquid)
Liquid Line

CH-Box Indoor Unit

Insulation
Multi-Kit [Cover the gas and liquid pipe with insulation.]

Charge the correct refrigerant Insulate the flare nut and union
quantity according to Table 8.1. of the piping connection with
If not, a compressor may be insulation.
damaged due to an excess or
insufficient refrigerant charge.
Check to ensure that there
is no gas leakage. If a large
Refrigerant charge from check refrigerant leakage occurs, it will
joint of gas stop valve may lead cause difficulty with breathing or
to compressor failure. Be sure harmful gases would occur if a
to charge refrigerant from the fire was being used in the room.
check joint of liquid stop valve.

Insulate the liquid piping and


gas piping completely to avoid
decreasing of performance and
dewing on the surface of the
pipe.

76 FAN-2207 201709

FAN-2209 201709 2-83


OUTDOOR UNIT

● Caution for Refrigerant Leakage

The room where the packaged air conditioner is installed, the refrigerant gas should be controlled not to
exceed the limit concentration in case of the refrigerant leakage.

The refrigerant R410A of incombustible and non-toxic is adopted with this unit. If by any chance the
refrigerant gas is leaked and filled in the room, the possibility of suffocation may occur.
The outdoor unit is multi-type air conditioner by connecting multiple indoor units with long distance piping.
Accordingly, the refrigerant charging quantity is larger than general individual unit. Before the indoor unit
installation, confirm that the room can keep the lower gas concentration than the limit value in order to take
the emergency countermeasures even if the gas leakage is occurred.

< Calculation of Refrigerant Concentration >


(1) Calculate the total quantity of refrigerant R (kg) charged in the system connecting all the indoor units
of rooms to be air-conditioned.
(2) Calculate the room Volume V (m3) of each room.
(3) Calculate the refrigerant concentration C (kg/m3) of the room according to the following equation.

R: Total Quantity of Charged Refrigerant (kg)


V: Room Volume (m3) = C: Refrigerant Concentration
< 0.42 (kg/m3) for R410A

The refrigerant R410A is non-toxic and inflammable in its original state.


However, in consideration of a state where the refrigerant leaks into the room, measures against
refrigerant leaks must be taken in small rooms where the tolerable level could be exceeded.
Take countermeasures by installing ventilation devices,etc.

250

Range below the


200 density
limit of 0.42kg/m3
Room Volume (m3)

(Countermeasures
Not Needed)
150

Range above the limit of


100 0.42kg/m3
(Countermeasures Needed)

50

0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150

Total Quantity Charged of Refrigerant (kg)

FAN-2207 201709 77

2-84 FAN-2209 201709


OUTDOOR UNIT

After calculation, the room to install this unit is proved not to keep the gas concentration lower than the limit
value. However, the air conditioner should be installed in this room from unavoidable circumstances, each of
the following countermeasures should be taken.

Outdoor Unit

Refrigerant Flow
Refrigerant Cycle

Indoor Unit

Room where the refrigerant leakage occurs


(Whole refrigerant in the cycle flows out.)

(1) The gas leakage detector & alarm system and interlocking mechanical ventilation equipment (with
ventilation capacity over 0.42m3/min per refrigerating ton) should be installed. Refer to the following
figure.
Outdoor Unit Refrigerating Refrigerating
Outdoor Unit
(HP) Ton Ton
8 3.08 32 12.31
10 3.69 34 13.12
12 4.52 36 13.94
14 5.34 38 14.38
16 6.15 40 15.60
18 6.97 42 16.01
20 7.59 44 17.26
22 8.63 46 17.67
24 9.04 48 18.08
26 9.86 50 19.28
28 10.67 52 19.61
30 11.49 54 19.93

(2) Provide the opening for ventilation between rooms* in order not to exceed the permissible
concentration.
* It is opening without door or opening at the top or bottom of door with floor space more than 0.15%.
< Example > Refrigerant Piping
Refrigerant Charge: 60kg

Outdoor Unit

Indoor Unit
The Smallest
Room

Medium-sized
Small Room Room Large Room

Mechanical Ventilation Equipment + Gas Leakage Detector & Alarm System

NOTES:
1. The quantity of refrigerant gas leakage against each room should be calculated as 60kg each.
2. The refrigerant concentration must be below 0.42 kg/m3 for each room.

The installer and system specialist shall secure against leakage according to local regulations or standards.
The following standards may be applicable, if local regulations are not available.
International Organization for Standardization, ISO5149 or European Standard, EN378 or Japan Standard,
KHKS0010.

78 FAN-2207 201709

FAN-2209 201709 2-85


OUTDOOR UNIT

9. Test Run
Test run should be performed according to the Item 9.2. And use the Table 9.1 for recording test run.

l An electrical shock will occur by residual voltage.


Turn OFF the power source completely before starting the maintenance for electrical parts.
Check to ensure that no residual voltage exists after turning OFF the power source.

l Check to ensure that each wire is correctly connected at each phase of power suplly. If it is
incorrectly connected, the unit will not operate and the alarm code will be indicated. In this case,
connect each wire correctly.
l Do not operate the system until all the check points have been cleared.
As for the test run of indoor unit, check “Installation & Maintenance Manual” attached to the indoor
unit.

9.1 Before Test Run


(1) Check to ensure that the refrigerant piping and transmission between outdoor unit and indoor units
are connected to the same refrigerant cycle. If not, it will cause an abnormal operation and a serious
accident.
Check that the dip switch settings of the refrigerant cycle No. (DSW1 & RSW1 [O.U.], DSW5 & RSW2
[I.U.]) and the unit number (RSW) for the indoor units apply to the system.
Confirm that the dip switch settings on the printed circuit board of the indoor units and the outdoor
units are correct. Especially, pay attention to the setting of outdoor unit No., the refrigerant cycle No.
and the end terminal resistance. Refer to the chapter “7. Electrical Wiring”.
(2) Check to ensure that the electrical resistance is more than 1 megohm, by measuring the resistance
between ground and the terminal of the electrical parts. If the electrical resistance is less than 1
megohm, do not operate the system until the electrical leakage is found and repaired (Refer to “Caution
for Insulation Resistance” for details.).
Do not impress the voltage on the terminals for transmission (Outdoor Unit: TB2 1, 2, 3, 4 /
Indoor Unit: TB2 A, B, 1, 2). Otherwise, it may cause failure.
(3) Check to ensure that each wire, L1, L2, L3 and N (R, S and T) is correctly connected to the power
source.
If it is incorrectly connected, the unit will not operate and the wired controller will indicate the alarm
code “05”. In this case, check and change the phase of the power source according to the sheet
attached to the reverse side of the service cover.
(4) Check to ensure that the switch of the main power source has been ON for more than
12 hours, to warm the compressor oil by the oil heater.
Outdoor unit does not operate for at most 4 hours after power supply (Stoppage Code d1-22).
In case of operation within 4 hours, release the protection control as follows:
1. Supply power to the outdoor unit.
2. Wait for 30 seconds.
3. Push PSW5 on the outdoor PCB for more than 3 seconds in order to release the d1-22.
In case of using wired controller for release
< For JCWB10NEWS >
* Press and hold “ ” (menu) and “ ” (return) simultaneously for at least 3 seconds. The test run
menu will be displayed.
* Press “ ” or “ ” to select “Outdoor Unit Comp. Pre-heating Indication / Cancel”. Press “OK” and
cancel the pre-heating control.
< For JCWA10NEWQ >
Push “Air Flow” and “Auto Louver” switch simultaneously for 3 seconds.
NOTE:
As for other remote controllers, refer to Installation and Maintenance Manual attached to each wired
controller.

FAN-2207 201709 79

2-86 FAN-2209 201709


OUTDOOR UNIT

(5) Be sure to close the service cover at the front lower side when the test run is performed.
(6) Combination Unit Model Label
In case of the combination of base units, attach the combination unit model label to a visible spot
of the main unit (outdoor unit A) so that the outdoor unit A can be identified easily.
Do not attach it to the sub unit (outdoor unit B and C).

Caution for Insulation Resistance


If total unit insulation resistance is lower than 1 megohm, the compressor insulation resistance may
be low due to refrigerant retained in the compressor. This may occur if the unit has not been used
for long periods.
1. Disconnect the cables to the compressor and measure the insulation resistance of the compressor
itself. If the resistance value is over 1 megohm, then insulation failure has occurred at other
electrical parts.
2. If the insulation resistance is less than 1 megohm, reconnect the compressor cables from the
inverter PCB. Then, turn on the main power to apply current to the crankcase heater.
After applying current for more than 3 hours, measure insulation resistance again. (Depending on
the air conditions, pipe length or refrigerant conditions, it may be necessary to apply the current
for a longer period of time.)
If the leakage breaker is activated, check the recommended size shown in Table 7.1 and 7.2.

NOTICE
1. Confirm that field-supplied electrical components (main switch fuse, fuse-free breaker, earth leakage
breakers, wires, conduit connectors and wire terminals) have been properly selected according to the
electrical data shown in Table 7.1 and 7.2, and ensure that the components comply with national and local
codes.
2. Use shielded wires (>0.75mm2) for field wiring to avoid electrical noise obstacle. (Total length of shielded
wire shall be less then 1000m, and size of shielded wire shall comply with local codes.)
3. Check the terminal for power source wiring (terminals “L1” to “L1” and “N” to “N” of each terminal block:
AC 400V, 380-415V, 380V, terminals “R” to “L1” and “S” to “L2” of each terminal block: AC 220V).
If not, some components will be damaged.

80 FAN-2207 201709

FAN-2209 201709 2-87


OUTDOOR UNIT

9.2 Test Run


This test run method is for the wired controller (Model: JCWB10NEWS). As for other remote controllers, refer
to Installation and Maintenance Manual attached to each wired controller.
(1) Check to ensure that stop valves for gas and liquid of the outdoor unit are fully opened.
(In the case of combined outdoor units, check to ensure that all stop valves of the outdoor units are
fully opened.)
(2) Perform the test run of indoor units one by one sequentially, and then check the accordance of the
refrigerant piping system and the electrical wiring system. (If the multiple indoor units are operated
simultaneously, the system accordance cannot be inspected.)
(3) Perform the test run according to the following procedure. Ensure that the unit operates without any
problem.
NOTE:
In the case that 2 wired controllers (main and sub) are installed to the system, perform the test run
from the main wired controller.

< For JCWB10NEWS >


(a) Press and hold “ ” (menu) and “ ” (return) simultaneously for at least 3 seconds. The test run
menu will be displayed.
(b) Select “Test Run” by pressing “ ” and press “OK”.
Test Run Screen
The test run screen will be displayed.
Test Run Setting: 2 units
l The total number of indoor units connected is indicated
MODE : COOL
on the LCD (Liquid crystal display). The twin combination
(one (1) set with two (2) indoor units) is indicated as “2 SPEED : MED
units”, and the triple combination (one (1) set with three (3)
indoor units) is indicated as “3 units”.
NOTE:
When “00 unit” is indicated, the auto-address function may SEL. ADJ RUN RTN.
be performing. Cancel “Test Run” mode and set it again.
l If the indicated number is not equal to the actual number of connected indoor units, the auto-
address function is not performed correctly due to incorrect wiring, the electric noise, etc.
Turn OFF the power supply, and correct the wiring after checking the following points (Do not
repeat turning ON and OFF within 10 seconds.)
* The power supply for the indoor unit is NOT turned ON or the incorrect wiring.
* Loose Connection between Indoor Units or Wired Controller
* Incorrect Setting of Indoor Unit Address (The indoor unit address is overlapped.)
(c) Start Test Run.
l Press “ ” (run/stop). The test run operation will start. The operation mode, the air flow volume,
the air flow direction and the test run time can be set on the test run screen. Select the item by
pressing “ ” and set the detail by pressing “ ”.
The default setting of the test run time is 2-hour OFF timer.
l Check the temperature conditions.
The unit operation cannot be performed if the conditions are out of range.
Refer to the table below for working range.
< Example >
The cooling operation is not performed if the outdoor temperature is below -5 oC DB.
Cooling Operation Heating Operation
o o
Indoor Minimum 21 C DB / 15 C WB 15oC DB
Temperature Maximum o o
32 C DB / 23 C WB 27oC DB
o
Outdoor Minimum -10 C DB (*) -20oC WB (**)
Temperature Maximum 48oC DB 15oC WB
DB: Dry Bulb, WB: Wet Bulb
NOTES:
(*) 10oC DB ~ -5oC DB, Operation Control Range
Cooling operation at minimum -10oC DB is available only for the unit up to 54HP with low ambient
setting.
The minimum cooling operation for 56HP to 96HP is -5oC DB.
(**) -12oC WB ~ -20oC WB, Operation Control Range

FAN-2207 201709 81

2-88 FAN-2209 201709


OUTDOOR UNIT

(d) Press “ ” or “ ”, select “LOUV.” and select “ ” (auto swing) by pressing “ ” or “ ”.


The auto swing operation will start. Check the operating sound at the louvers.
If abnormal sound is generated from louvers, it may be caused by deformation of the air panel due
to incorrect installation. In this case, install the air panel again without deformation. If abnormal
sound is not generated, press “ ” or “ ” again to stop the auto swing operation.
(e) Though the temperature detections by the thermistors are invalid, the protection devices are valid
during the test run. If an alarm occurs, refer to Table 9.2, Alarm Code and perform troubleshooting.
Then perform the test run again.
(f) According to the label “Checking Method by 7-Segment Display” attached to the back side of the
service cover of the outdoor unit, check the temperature, the pressure and the operation frequency
of the specified portions, and check the number of the connected indoor units on 7-segment
displays.
(g) To finish the test run, wait for 2 hours (as default setting) or press “ “ (run/stop) switch again.
l Flashing the operation lamp for 2 seconds ON and 2 seconds OFF is for abnormality of the
transmitting between the indoor unit and the wired controller (loosened or disconnected
connector, disconnected wires, or incorrect wiring etc.)
l Small sound may be heard from the outdoor unit after turning ON the power source because the
electrical expansion valve is activated to adjust the opening. Therefore, there is no abnormality
of the unit.
l Sound may be heard from the outdoor unit for seconds after running or stopping the compressor,
starting or finishing the defrosting, etc. It generates because of the pressure difference inside the
piping from the compressor. Therefore, there is no abnormality of the unit.

Do NOT operate the air conditioners to check the electrical wiring, etc until the preparation of
the test run is completed.

82 FAN-2207 201709

FAN-2209 201709 2-89


OUTDOOR UNIT

Table 9.1 Test Run and Maintenance Record

MODEL: SERIAL. No. COMPRESSOR MFG. No.

CUSTOMER'S NAME AND ADDRESS: DATE:

1. Is the rotation direction of the indoor fan correct?

2. Is the rotation direction of the outdoor fan correct?

3. Are there any abnormal compressor sounds?

4. Has the unit been operated at least twenty (20) minutes?

5. Check Room Temperature


o o o o
Inlet: No. 1 DB /WB C, No. 2 DB /WB C, No. 3 DB /WB C, No. 4 DB /WB C
o o o o
Outlet: DB /WB C, DB /WB C, DB /WB C, DB /WB C
o o o o
Inlet: No. 5 DB /WB C, No. 6 DB /WB C, No. 7 DB /WB C, No. 8 DB /WB C
o o o o
Outlet: DB /WB C, DB /WB C, DB /WB C, DB /WB C

6. Check Outdoor Ambient Temperature


o o
Inlet: DB C, WB C
o o
Outlet: DB C, WB C

7. Check Refrigerant Temperature


o
Liquid Temperature: C
o
Discharge Gas Temperature: C

8. Check Pressure
Discharge Pressure: MPa
Suction Pressure: MPa

9. Check Voltage
Rated Voltage: V
Operating Voltage: L1-L2 V, L1-L3 V, L2-L3 V
Starting Voltage: V
V
Phase Imbalance: 1- =
Vm

10. Check Compressor Input Running Current


Input: kW
Running Current: A

11. Is the refrigerant charge adequate?

12. Do the operation control devices operate correctly?

13. Do the safety devices operate correctly?

14. Has the unit been checked for refrigerant leakage?

15. Is the unit clean inside and outside?

16. Are all cabinet panels fixed?

17. Are all cabinet panels free from rattles?

18. Is the filter clean?

19. Is the heat exchanger clean?

20. Are the stop valves open?

21. Does the drain water flow smoothly from the drain pipe?

FAN-2207 201709 83

2-90 FAN-2209 201709


OUTDOOR UNIT

Table 9.2 Alarm Code

Code Category Content of Abnormality Leading Cause


Activation of Float Switch (High Water Level in Drain Pan,
01 Indoor Unit Activation of Protection Device (Float Switch)
Abnormality of Drain Pipe, Float Switch, or Drain Pan)
Activation of Protection Device Activation of PSH (Pipe Clogging, Excessive Refrigerant, Inert
02 Outdoor Unit
(High Pressure Cut) Gas Mixing)
Incorrect Wiring, Loose Terminals, Disconnected
Abnormal Communication between
03 Communication Cable, Blowout of Fuse, Indoor Unit Power
Indoor Units and Outdoor Units
Communication OFF
Abnormal Communication between Inverter PCB -Outdoor PCB Communication Failure
04
Inverter PCB and Outdoor PCB (Loose Connector, Wire Breaking, Blowout of Fuse)
Incorrect Power Supply, Connection to Reversed Phase,
05 Supply Phase Abnormality of Power Supply Phases
Open-Phase
06 Voltage Abnormal Inverter Voltage Outdoor Voltage Decrease, Insufficient Power Capacity
Excessive Refrigerant Charge, Failure of Thermistor, Incorrect
07 Decrease in Discharge Gas Superheat Wiring, Incorrect Piping Connection, Expansion Valve Locking
at Opened Position (Disconnect Connector)
Cycle Insufficient Refrigerant Charge, Pipe Clogging, Failure of
Thermistor, Incorrect Wiring, Incorrect Piping Connection,
08 Increase in Discharge Gas Temperature
Expansion Valve Locking at Closed Position (Disconnect
Connector)
Abnormal Communication between
0A Communication Incorrect Wiring, Breaking Wire, Loose Terminals
Outdoor Units
Duplication of Address Setting for Outdoor Units (Sub Units) in
0b Incorrect Outdoor Unit Address Setting
Same Refrigerant Cycle Number
Outdoor Unit
Two (or more) Outdoor Units Set as "Main Unit" Exist in Same
0C Incorrect Outdoor Unit Main Unit Setting
Refrigerant Cycle Number
11 Abnormality of Inlet Air Thermistor
12 Abnormality of Outlet Air Thermistor
13 Abnormality of Freeze Protection Thermistor
14 Sensor on Abnormality of Gas Piping Thermistor Incorrect Wiring, Disconnecting Wiring,
Indoor Unit Abnormality of Outdoor Air Thermistor Breaking Wire, Short Circuit
15
(EconoFresh)
16 Abnormality of Remote Sensor (DOAS)
Abnormality of Thermistor Built-in Remote
17
Controller (DOAS)
Abnormality of Indoor Fan Motor (Step-Out),
18 Indoor Fan Abnormality of Indoor Fan System
Indoor Fan Controller Failure
Motor
19 Activation of Protection Device for Indoor Fan Fan Motor Overheat, Lockup
Abnormality of Fin Thermistor or Fan Controller,
1A Abnormality of Fan Controller Fin Temperature
Heat Exchanger Clogging, Abnormality of Fan Motor
1b Activation of Overcurrent Protection Abnormality of Fan Motor
Indoor Fan
1C Problem with Current Sensor Abnormality of Fan Controller Current Sensor
Controller
1d Activation Fan Controller Protection Driver IC Error Signal Detection, Instantaneous Overcurrent
Indoor Voltage Decrease, Insufficient Capacity of
1E Abnormality of Indoor Fan Controller Voltage
Power Supply Wiring
21 Abnormality of High Pressure Sensor
22 Abnormality of Outdoor Air Thermistor
Abnormality of Discharge Gas Thermistor on
23
Sensor on Top of Compressor Incorrect Wiring, Disconnecting Wiring,
Outdoor Unit Abnormality of Heat Exchanger Liquid Pipe Breaking Wire, Short Circuit
24
Thermistor
Abnormality of Heat Exchanger Gas Pipe
25
Thermistor
29 Abnormality of Low Pressure Sensor
Connection of CH-Box to Heat Pump System,
Incorrect DSW Settings of Outdoor Unit for Disconnection of CH-Box to Heat Recovery System
30
CH-Box CH Unit(Generation 1 model) and CH-Box(Generation 2
model) are used in the same system together.
Incorrect Capacity Setting of Outdoor Unit and Incorrect Capacity Setting of Outdoor Unit and Indoor Unit,
31
System Indoor Unit Excessive or Insufficient Indoor Unit Total Capacity Code
Duplication of Indoor Unit No. In same Refrigerant Cycle
35 Incorrect Setting of Indoor Unit No.
Number
36 Incorrect of Indoor Unit Combination Indoor Unit is Designed for R22
Abnormality of Picking up Circuit for Protection Failure of Protection Detecting Device (Incorrect Wiring of
38
in Outdoor Unit Outdoor PCB)

84 FAN-2207 201709

FAN-2209 201709 2-91


OUTDOOR UNIT

Code Category Content of Abnormality Leading Cause


3A Abnormality of Outdoor Unit Capacity Outdoor Unit Capacity > 54HP
Incorrect Setting of Outdoor Unit Models Incorrect Setting of Main and Sub Units(s) Combination or
3b
Combination or Voltage Voltage
Outdoor Unit Abnormal Communication between Main Unit
3d Incorrect Wiring, Disconnect Wire, Breaking Wire, PCB Failure
and Sub Unit(s)
Abnormal Combination between Inverter PCB Incorrect Combination between Inverter PCB and Outdoor
3E
and Outdoor PCB PCB
Activation of Pressure Ratio Decrease Defective Compression (Failure of Compressor or Inverter,
43
Protection Loose Power Supply Connection)
Overload at Cooling, High Temperature at Heating, Expansion
44 Activation of Low Pressure Increase Protection
Valve Locking at Open Position (Loose Connector)
Protection Overload Operation (Heat Exchanger Clogging, Short Circuit
Activation of High Pressure Increase
45 Device of Airflow), Pipe Clogging, Excessive Refrigerant, Inert Gas
Protection
Mixing
Activation of Low Pressure Decrease Insufficient Refrigerant, Piping Clogging, Expansion Valve
47
Protection Locking at Close Position (Loosen Connector)
48 Activation of Inverter Overcurrent Protection Overload Operation, Compressor Failure
51 Sensor Abnormal Inverter Current Sensor Current Sensor Failure
Driver IC Error Signal Detection (Protection for Overcurrent,
53 Inverter Error Signal Detection
Voltage Decrease, Short Circuit), Instantaneous Overcurrent
Inverter Abnormal Inverter Fin Thermistor,
54 Abnormality of Inverter Fin Temperature
Heat Exchanger Clogging, Fan Motor Failure
55 Inverter Failure Inverter PCB Failure
Driver IC Error Signal Detection (Protection for Overcurrent,
57 Activation of Fan Controller Protection
Voltage Decrease, Short Circuit), Instantaneous Overcurrent
Fin Thermistor Failure, Heat Exchanger Clogging, Fan Motor
5A Abnormality of Fan Controller Fin Temperature
Failure
Fan Controller
5b Activation of Overcurrent Protection Fan Motor Failure
Failure of Current Sensor (Instantaneous Overcurrent,
5C Abnormality of Fan Controller Sensor Increase of Fin Temperature, Voltage Decrease, Grand Fault,
Step-Out)
A1 External Input Detection of External Abnormality Input Signal by External Abnormality Detection Setting
b0 Incorrect Setting of Unit Model Code Incorrect Setting of Indoor Unit Model
Incorrect Setting of Unit and Refrigerant Cycle
b1 64 or More Number is Set for Address or Refrigerant Cycle
Number
b2 Indoor Unit Abnormality of EEPROM EEPROM failure, Incorrect Data of EEPROM
There are 17 or More Non-Corresponding to H-LINK II Units
b5 Incorrect Indoor Unit No. Setting
are Connected to One System.
Abnormal Communication between Communication Failure, Disconnected Communication Cable,
b6
Indoor PCB and Indoor Fan Controller Abnormal Connection
2 or More CH-Boxes are Connected between
C1 Incorrect CH-Box Connection
Outdoor Unit and Indoor Unit
9 or More Indoor Units Connected to Single Branch Type CH-Box
C2 Incorrect Indoor Unit Connection Number 7 or More Indoor Units Connected per a Branch of Multiple
Branch Type CH-Box
CH-Box Incorrect Indoor Unit Refrigerant Number Indoor Units of Different Refrigerant Cycle Number are
C3
Setting Connected to CH-Box
Incorrect Connection between CH-Box and
C4 This Outdoor Unit is not compatible with this CH-Box.
Outdoor Units
Indoor Unit is connected to a port that is set to not used for
C5 Incorrect Connection Port Setting
Multiple Branch Type CH-Box.
This alarm code appears when the following alarms* occurs
Compressor Protection Alarm
EE Compressor three times within 6 hours.
(It can not be reset from Wired Controller)
*02, 07, 08, 39, 43 to 45, 47

FAN-2207 201709 85

2-92 FAN-2209 201709


OUTDOOR UNIT

10. Safety and Control Device Setting


• Compressor Protection
The compressor is protected by the following devices and their combinations.
(1) High Pressure Switch: This switch cuts out the operation of the compressor when the discharge
pressure exceeds the setting.
(2) Oil Heater: This band type heater protects against oil foaming during cold starting, as it is energized
while the compressor is stopped.

< FSXNS >


JTOR080VPE JTOR100VPE JTOR120VPE JTOR140VPE JTOR160VPE
Model
(U, F, R) BS1 (U, F, R) BS1 (U, F, R) BS1 (U, F, R) BS1 (U, F, R) BS1
For Compressor Automatic Reset, Non-Adjustable
Pressure Switches (each one for each compressor)
-0.05 -0.05 -0.05 -0.05 -0.05
High Cut-Out MPa 4.15 4.15 4.15 4.15 4.15
-0.15 -0.15 -0.15 -0.15 -0.15
Cut-In MPa 3.20+0.15 3.20+0.15 3.20+0.15 3.20+0.15 3.20+0.15
Fuse Capacity
3~, 220V, 60Hz A 70 70 80 80 70
3~, 460V, 60Hz
3N~, 380V, 60Hz A 50 50 50 50 50
Oil Heater
Capacity W 37.3 x 3 37.3 x 3 37.3 x 3 37.3 x 3 37.3 x 6
CCP Timer Non-Adjustable
Setting Time min. 3 3 3 3 3
For DC Fan Module
Fuse Capacity
3~, 220V, 60Hz A 10 10 10 10 10
3~, 460V, 60Hz
3N~, 380V, 60Hz A 5 5 5 10 5

JTOR180VPE JTOR200VPE JTOR220VPE JTOR240VPE


Model
(U, F, R) BS1 (U, F, R) BS1 (U, F, R) BS1 (U, F, R) BS1
For Compressor Automatic Reset, Non-Adjustable
Pressure Switches (each one for each compressor)
-0.05 -0.05 -0.05 -0.05
High Cut-Out MPa 4.15 4.15 4.15 4.15
-0.15 -0.15 -0.15 -0.15
Cut-In MPa 3.20+0.15 3.20+0.15 3.20+0.15 3.20+0.15
Fuse Capacity
3~, 220V, 60Hz A 70 70 80 80
3~, 460V, 60Hz
3N~, 380V, 60Hz A 50 50 50 50
Oil Heater
Capacity W 37.3 x 6 37.3 x 6 37.3 x 6 37.3 x 6
CCP Timer Non-Adjustable
Setting Time min. 3 3 3 3
For DC Fan Module
Fuse Capacity
3~, 220V, 60Hz A 10 10 10 10
3~, 460V, 60Hz
3N~, 380V, 60Hz A 5 5 5 5

86 FAN-2207 201709

FAN-2209 201709 2-93


OUTDOOR UNIT

© 2017 Johnson Controls, Inc. www.johnsoncontrols.com Form FAN-2207 201709

Johnson Controls reserve the right to change product features without prior notice.

P5417049

2-94 FAN-2209 201709


PIPING CONNECTION KIT

Installation Manual for Multi-Kits


Piping Connection Kit Models: MC-NP20SX, MC-NP21SX, MC-NP30SX

NOTE
Hand over this installation manual to the next installation work personal.

1. Applicable Outdoor Units


These multiple piping connection kits can be applied to the R410A VRF systems.

2. Transportation
Transport the product as close to the installation location as practical before unpacking.

Do not put any material on the product.

3. Before Installation
Confirm the number of the following parts by referring to the model printed on the package before unpacking.
Do NOT put any foreign material into the parts. Check to confirm that no foreign materials are inside the parts
before installation.
NOTICE:
If any of these parts are missing, please contact your distributor. Do not discard any foam packaging as it is
used as insulation for the joint kits after pressure testing is complete.
Model MC-NP30SX
MC-NP20SX MC-NP21SX
Piping Connection Kit 1 Piping Connection Kit 2
Name of Parts Qty. Qty. Qty. Qty.
Branch Pipe for
Low Pressure
Gas Line 1 1 1 1
Branch Pipe for
High/Low Pressure
Gas Line 1 1 1 1

Branch Pipe for


Liquid Line
1 1 1 1
Insulation for
Low Pressure
Gas Line 1 set 1 set 1 set 1 set
Insulation for
High/Low Pressure
Gas Line 1 set 1 set 1 set 1 set

Insulation for
Liquid Line
1 set 1 set 1 set 1 set

Reducer for 1 1 1 1
Low Pressure
Gas Line Connection
(For Connecting Pipe
1 1 1 1
Accessory

(Field-Supplied))
- - -
None None 1 None

Reducer for 1 1 1 1
High/Low Pressure
Gas Line Connection
(For Connecting Pipe
1 1 1 1
(Field-Supplied))

2 2 1 2

Reducer for
Liquid Line Connection 1 1 1 1
(For Connecting Pipe
(Field-Supplied)) - - -
None None 1 None

Tape
3 3 3 3
P5417030

FAN-2209 201709 2-95


PIPING CONNECTION KIT

4. Installation Work
4.1 Piping Connection Size
The ends of the multi-kits are finished as shown in the following figures. Cut the end of the pipe to correspond to
the pipe size.

Allow adequate space for elbow, angled, and irregular piping arrangements to compensate for
expansion and contraction brought on by temperature change.

Unit: inch, ID: Inner Diameter, OD: Outer Diameter


Reducer for Reducer for
Branch Pipe for Branch Pipe for
Branch Pipe for Low High/Low Reducer for
Model Low Pressure High/Low Pressure
Liquid Line Pressure Pressure Liquid Line
Gas Line Gas Line
Gas Line Gas Line

OD 25.4
ID 19.05 ID 19.05 ID 12.7 ID 9.52 ID 25.4
OD 25.4
ID 22.2 ID 22.2 ID 22.2 ID 22.2 ID 15.88 ID 22.2
ID 25.4
457 457 378 ID 19.05
ID 22.2
ID 25.4 ID 25.4 ID 25.4 ID 25.4 ID 15.88
ID 19.05
ID 19.05 OD 25.4 OD 19.05
ID 28.58 ID 28.58
ID 19.05
MC- ID 15.88
NP20SX
ID 25.4 ID 12.7
OD 25.4

80
ID 19.05 ID 22.2
84

84

ID 25.4 ID 25.4 ID 9.52


303 ID 19.05
366 366 OD 25.4 ID 22.2
(To Outdoor Unit) (To Outdoor Unit) (To Outdoor Unit)
ID 25.4
(To Indoor Unit) (To Indoor Unit) (To Indoor Unit) ID 19.05
ID 22.2
ID 25.4
(Qty.: 2)
OD 28.58
ID 22.2 ID 19.05 ID 12.7 ID 9.52 OD 28.58
ID 28.58
ID 31.75 ID 25.4 ID 25.4 ID 22.2 ID 15.88
ID 25.4
469 484 378 ID 28.58
ID 22.2
ID 38.1 ID 28.58 ID 25.4 ID 25.4
ID 15.88
ID 28.58 ID 31.75 ID 19.05 ID 22.2 ID 19.05 OD 19.05
ID 22.2
MC- ID 15.88
NP21SX OD 25.4 ID 12.7
ID 28.58 ID 22.2
95

80

ID 28.58
95

ID 19.05 ID 25.4 ID 9.52


ID 25.4
383 402 303
OD 25.4 ID 22.2
(To Outdoor Unit) (To Outdoor Unit) (To Outdoor Unit)
(To Indoor Unit) (To Indoor Unit)
(To Indoor Unit) OD 28.58 ID 19.05
ID 28.58 ID 25.4
(Qty.: 2)
OD 28.58 OD 28.58

(To Piping Connection Kit 2) (To Piping Connection Kit 2) (To Piping Connection Kit 2)
ID 28.58 ID 28.58
ID 31.75 ID 25.4 ID 31.75 ID 25.4 ID 15.88 ID 9.52 ID 25.4 ID 25.4 OD 19.05
472 472 378
Piping Connection Kit 1

ID 22.2 ID 22.2
ID 28.58 ID 28.58 ID 12.7 ID 15.88
ID 31.75 ID 31.75 ID 25.4
ID 15.88 ID 12.7
ID 38.1 ID 31.75
ID 38.1 ID 19.05 ID 28.58
ID 9.52

OD 31.75
95

OD 28.58
95

80

ID 28.58 ID 28.58 ID 19.05


382 382 303
ID 25.4 ID 22.2
(To Outdoor Unit) (To Outdoor Unit) OD 31.75 OD 15.88
(To Outdoor Unit)
ID 38.1
(To Indoor Unit) (To Indoor Unit)
(To Indoor Unit) OD 28.58
ID 19.05
ID 28.58
MC-
NP30SX
OD 25.4
ID 19.05 ID 12.7 ID 9.52 OD 28.58 ID 25.4
ID 31.75 ID 25.4 ID 22.2 ID 22.2 ID 15.88 ID 22.2
472 457 378 ID 28.58 ID 19.05
Piping Connection Kit 2

ID 28.58 ID 25.4 ID 15.88 ID 25.4


ID 31.75 ID 25.4 ID 22.2 OD 19.05
ID 19.05 ID 19.05
ID 38.1 ID 28.58
ID 22.2
ID 15.88
OD 25.4 ID 12.7
84

ID 25.4 ID 9.52
80

ID 25.4
95

ID 28.58 ID 19.05 ID 25.4


382 366 303 ID 28.58
OD 25.4 ID 22.2
(To Outdoor Unit) (To Outdoor Unit) (To Outdoor Unit)
(To Piping Connection Kit 1) (To Piping Connection Kit 1)
(To Piping Connection Kit 1) OD 28.58 ID 19.05
ID 25.4 (Qty.: 2)

2-96 FAN-2209 201709


PIPING CONNECTION KIT

4.2 Installation Position


• Horizontal Installation
Locate the branch pipes to become the “Y” union pipe section with the affixed caution label.
(Inclination within +15o)
Make the straight section a minimum of 500mm after the vertical bend.
NOTICE:
Incorrect installation can result in the failure of the outdoor unit.

Upward
Straight Section Inclination
within +15o
Min. 500mm Caution Label
o
+15
Downward Inclination
Horizontally A (View from A)
INCORRECT

4.3 Piping Connection


Perform piping connections work by referring to the figure below.
Refer to the installation and maintenance manual for outdoor units for piping length between outdoor units and
between piping connection kits.

Example: Combination of three Outdoor Units

Use the field-supplied connecting pipe in accordance with the installation and maintenance manual for the outdoor
units. If necessary, use a reducer (accessory).

Front Side Piping Connection


High/Low Pressure
Gas Piping Piping Connection Kit 1 Accessory
(Field-Supplied) (Liquid) Pipe Outdoor Unit A

Liquid Piping
(Field-Supplied) Piping Connection Kit 2
(Liquid)
Accessory Outdoor Unit B
Pipe
Outdoor Unit C

Low Pressure
Gas Piping
(Field-Supplied) Foundation

P
Piping Connection Kit 1
(Low Pressure Gas) View from P

Accessory Pipe Foundation


(L-Shape) Accessory
Low Pressure Pipe
Piping Connection Kit 1 Gas Piping
(High/Low Pressure Gas) (Field-Supplied)
High/Low Pressure
Accessory Pipe Gas Piping Min. 5-7/8 in.
Piping Connection Kit 2 (150mm)
(Low Pressure Gas) (L-Shape) (Field-Supplied)
Min. 19-11/16 in.
Piping Connection Kit 2 Liquid Piping High/Low Pressure
(500mm)
(High/Low Pressure Gas) (Field-Supplied) Gas Piping
(Field-Supplied)

Downward Piping Connection


Piping Connection Kit 1 Accessory Pipe Outdoor Unit A
(Liquid) (Z-Shape)
Piping Connection Kit 2
Liquid Piping (Liquid)
(Field-Supplied)
Accessory Pipe
High/Low Pressure (Z-Shape)
Gas Piping
(Field-Supplied) Outdoor Unit B
Base
Low Pressure Gas Piping (Field-Supplied)
(Field-Supplied)

Piping Connection Kit 1


(High/Low Pressure Gas)
Accessory Pipe
Piping Connection Kit 1 (L-Shape)
(Low Pressure Gas)

Piping Connection Kit 2


(High/Low Pressure Gas)
Accessory Pipe
Piping Connection Kit 2 (L-Shape)
(Low Pressure Gas) Outdoor Unit C
High/Low Pressure
Liquid Piping Gas Piping Low Pressure Gas Piping
(Field-Supplied) (Field-Supplied) (Field-Supplied)

FAN-2209 201709 2-97


PIPING CONNECTION KIT

4.4 Piping Work


(1) When the branched pipe size is 22.2mm or less in inner diameter, a field-supplied mini-copper tube cutter is
required.
(mm)
Recommended Mini-Copper Tube Cutter Available Cut Size Rotating Radius

(21)

(43)
f5 - 28 (50)

(70)
70 or less

(2) Use clean copper pipes without any moisture or foreign materials on inner surface of pipes. When
connecting refrigerant pipe, cut the copper pipes with a copper tube cutter as shown below. Also deburr
the cutting edge using deburring tool to ensure that no burr goes inside the pipe. Blow-out the pipes with
nitrogen or compressed air to ensure that no dust remains inside the pipe. Do NOT use a saw, a grindstone
or other tools which causes a large amount of powder residue when cutting.

Copper Tube Cutter

Pipe

Deburring
Connection
Part

(3) When cutting the pipe, allow for an adequate depth for brazing as shown in the following table.

(mm)
Diameter Min. Insertion Depth
(A) (B) B
Over 5, Below 8 6
Over 8, Below 12 7
Over 12, Below 16 8
A

Over 16, Below 25 10


Over 25, Below 35 12
Over 35, Below 45 14

● Caution for Refrigerant Piping

When installing pipe through the Do NOT place the pipe directly In case of rain attach a cap or
wall, secure a cap at the end of on the ground. put a plastic bag over the pipe end.
the pipe.
INCORRECT CORRECT INCORRECT CORRECT INCORRECT
Hole
Attach a cap Rain water
or plastic bag can enter.
Attach a cap with rubber
Attach a cap or vinyl tape. band.
or vinyl tape.
CORRECT

2-98 FAN-2209 201709


PIPING CONNECTION KIT

(4) Make sure that all stop valves for the outdoor unit are closed completely.
(5) Blow-out the inside of the pipes with nitrogen gas before brazing. Bleed nitrogen gas through piping during
brazing. Pressure not to exceed 0.02MPa.

Make sure that a test for leakage of refrigerant gases has been performed. The refrigerant used for this
unit (HFC R410A), is a non-flammable, non-toxic, and odorless gas. However if refrigerant should leak
and make contact with sparks, and catch on fire, toxic gas will be generated. Fluorocarbon, which is
heavier than air, will form on the floor surface and could cause suffocation.

(6) The airtight test pressure for this product is 4.15MPa.


(7) Install the field-supplied insulation with these multi-kits to each branch (liquid side and gas or vapor side),
with tape. Also, apply the field-supplied insulation for these units.

NOTICE
When polyethylene foam is applied, a thickness of 10mm for liquid piping and 15 to 20mm for gas piping is
recommended. (Use a grade of insulation with heat resistance of 100ºC for gas piping.)

Wrap the insultation tape without gap between


Insulation (Field-Supplied)
accessory insulation and field-supplied insulation.

Insulation for Gas and


Liquid Line (Accessory)

Do NOT leave a gap


between the insulation.

Fix the insulation with


tape (accessory) completely
after taping temporary. Insulation Tape (Field-Supplied)

● Perform insulation work only when the surface temperature of the pipe material has cooled to room
temperature. Anything done immediately after brazing can cause the insulation to melt.
● During piping work, always cover over or plug the open end to keep the inside free of dust and moisture.

After installation, it is recommended that the customer retain this manual for future reference.

© 2017 Johnson Controls-Hitachi Air Conditioning Technology (Hong Kong) Ltd.

P5417030, 2017

FAN-2209 201709 2-99


MULTI-KIT

Installation Manual for Multi-Kits


Line Branch Models: MW-NP142X3, MW-NP282X3, MW-NP452X3,
MW-NP562X3, MW-NP692X3, MW-NP902X3

NOTE
Hand over this installation manual to the next installation work personal.

1. Applicable Outdoor Units


These multiple line branches can be applied to the R410A VRF systems.

2. Transportation
Transport the product as close to the installation location as practical before unpacking.

Do not put any material on the product.

3. Before Installation
Confirm the number of the following parts by referring to the model printed on the package before unpacking.
Do NOT put any foreign material into the parts. Check to confirm that no foreign materials are inside the parts
before installation.

NOTICE:
If any of these parts are missing, please contact your distributor. Do not discard any foam packaging as it is
used as insulation for the joint kits after pressure testing is complete.
Model MW-NP142X3 MW-NP282X3 MW-NP452X3 MW-NP562X3 MW-NP692X3 MW-NP902X3
Name of Parts Qty. Qty. Qty. Qty. Qty. Qty.

Branch Pipe for


Low Pressure
Gas Line 1 1 1 1 1 1

Branch Pipe for


High/Low Pressure
Gas Line 1 1 1 1 1 1

Branch Pipe for


Liquid Line
1 1 1 1 1 1

Insulation for
Low Pressure
Gas Line 1 set 1 set 1 set 1 set 1 set 1 set
Insulation for
High/Low
Pressure
Gas Line 1 set 1 set 1 set 1 set 1 set 1 set

Insulation for
Liquid Line 1 set 1 set 1 set 1 set 1 set 1 set
Accessory

Reducer for Gas None None 1 1 2 2


Line Connection
(For Connecting
None None None None None 1
Pipe
(Field-Supplied))
None None None None None 2
Reducer for Liquid
Line Connection
(For Connecting
Pipe
(Field-Supplied)) 2 1 1 1 1 1

Tape
3 3 3 3 3 3

P5416979

2-100 FAN-2209 201709


MULTI-KIT

4. Installation Work
4.1 Piping Connection Size
The ends of the multi-kits are finished as shown in the following figures. Cut the end of the pipe to correspond to
the pipe size.

Allow adequate space for elbow, angled, and irregular piping arrangements to compensate for expansion
and contraction brought on by temperature change.

Unit: mm, ID: Inner Diameter


Branch Pipe for Branch Pipe for Branch Pipe for
Model
Low Pressure Gas Line High/Low Pressure Gas Line Liquid Line
(To Main Piping)
(To Main Piping)
ID 12.7
(To Main Piping)
ID 22.2 ID 9.52
ID 15.88
ID 12.7 ID 6.35
ID 19.05 ID 12.7
ID 19.05
ID 9.52
ID 15.88 ID 9.52
ID 22.2

MW-NP142X3 ID 12.7
ID 9.52

ID 19.05 ID 9.52 ID 6.35

ID 15.88 ID 6.35 (To Outdoor Unit)


(To Outdoor Unit) (To Outdoor Unit) (To Indoor Unit)
ID 12.7
(To Indoor Unit)
(To Indoor Unit)

(To Main Piping) (To Main Piping)


ID 12.7 ID 12.7
ID 22.2 ID 22.2 (To Main Piping)
ID 15.88 ID 15.88
ID 19.05 ID 19.05 ID 6.35
ID 19.05 ID 19.05
ID 9.52
ID 15.88 ID 22.2 ID 15.88 ID 9.52
ID 22.2

MW-NP282X3 ID 9.52

ID 19.05 ID 19.05 ID 6.35

ID 15.88 ID 15.88 (To Outdoor Unit)


(To Outdoor Unit) (To Outdoor Unit)
(To Indoor Unit)
ID 12.7 ID 12.7
(To Indoor Unit) (To Indoor Unit)

(To Main Piping)


(To Main Piping) (To Main Piping)
ID 28.58 ID 12.7
ID 28.58 ID 22.2 ID 9.52
ID 25.4 ID 15.88
ID 19.05 ID 12.7 ID 12.7
ID 22.2 ID 19.05
ID 15.88 ID 22.2

MW-NP452X3 ID 22.2 ID 12.7

(To Outdoor Unit) ID 19.05 ID 9.52


ID 19.05
ID 15.88 ID 6.35
ID 15.88 (To Outdoor Unit) (To Outdoor Unit)
ID 12.7
(To Indoor Unit) ID 12.7 (To Indoor Unit)
(To Indoor Unit)

(To Main Piping) (To Main Piping)


(To Main Piping) ID 15.88
ID 28.58 ID 12.7 ID 9.52
ID 28.58 ID 19.05
ID 25.4 ID 22.2 ID 12.7
ID 15.88
ID 19.05 ID 22.2 ID 15.88
ID 22.2 ID 19.05
ID 15.88 ID 22.2

MW-NP562X3 ID 22.2
ID 15.88
(To Outdoor Unit) ID 19.05 ID 19.05
ID 12.7
ID 15.88 ID 6.35
ID 15.88 (To Outdoor Unit) ID 9.52
ID 12.7 (To Outdoor Unit)
(To Indoor Unit) ID 12.7
(To Indoor Unit) (To Indoor Unit)

(To Main Piping)


(To Main Piping) (To Main Piping) ID 15.88
ID 28.58 ID 28.58 ID 9.52
ID 28.58 ID 28.58 ID 19.05
ID 25.4 ID 25.4 ID 12.7
ID 22.2 ID 15.88
ID 22.2 ID 22.2

MW-NP692X3 ID 22.2 ID 22.2


ID 15.88
(To Outdoor Unit) (To Outdoor Unit) ID 19.05
ID 19.05
ID 12.7
ID 6.35
ID 15.88 ID 15.88 ID 9.52
(To Outdoor Unit)
(To Indoor Unit) ID 12.7 (To Indoor Unit) ID 12.7
(To Indoor Unit)

(To Main Piping)


(To Main Piping)
ID 38.1 ID 28.58 (To Main Piping)
ID 28.58 ID 15.88 ID 9.52
ID 31.75 ID 34.93 ID 25.4
ID 19.05 ID 12.7
ID 38.1 ID 31.75 ID 22.2
ID 22.2 ID 15.88

MW-NP902X3
ID 22.2 ID 19.05
ID 15.88
(To Outdoor Unit) ID 19.05
(To Outdoor Unit) ID 22.2
ID 12.7
ID 6.35
ID 28.58 ID 15.88 ID 9.52

(To Outdoor Unit) (To Indoor Unit)


(To Indoor Unit) ID 12.7
(To Indoor Unit)

FAN-2209 201709 2-101


MULTI-KIT

Unit: mm, ID: Inner Diameter, OD: Outer Diameter


Model Reducer for Gas Line Reducer for Liquid Line

OD 6.35
MW-NP142X3
ID 9.52
(Qty. 2)

OD 6.35
MW-NP282X3
ID 9.52

OD 28.58 ID 25.4 ID 12.7


OD 6.35
MW-NP452X3 ID 15.88
ID 9.52
ID 22.2 ID 19.05

OD 28.58 ID 25.4 ID 12.7


OD 6.35
MW-NP562X3 ID 15.88
ID 9.52
ID 22.2 ID 19.05

OD 28.58 ID 25.4 ID 12.7


OD 6.35
MW-NP692X3 ID 15.88
ID 9.52
ID 22.2 ID 19.05
(Qty. 2)

OD 28.58 ID 25.4 ID 12.7 OD 31.75 ID 28.58


OD 28.58 ID 31.75 OD 6.35
MW-NP902X3 ID 15.88
ID 22.2 ID 19.05 ID 9.52
ID 25.4 ID 22.2
(Qty. 2) (Qty. 2)

4.2 Installation Position


(1) Horizontal Installation
Locate the “Y” union pipe section on the same horizontal plane. (Inclination within 30o)
Make the straight section a minimum of 500mm after the vertical bend.

Upward
Total Straight Section
Inclination
Min. 500mm within 30o

o
30
Horizontally
Downward A Inclination
(View from A)
INCORRECT

(2) Vertical Installation


Straight section of the pipe connection on the outdoor unit side is made as follows:
a) The collective pipe connection part is installed upward; the straight section must be a minimum of
500mm.
b) The collective pipe connection part is installed downward; the straight section must be a minimum of
500mm.

Upward

Total Straight Section


Min. 500mm

Total Straight Section


Min. 500mm

Downward

2-102 FAN-2209 201709


MULTI-KIT

(3) Piping from Multi-Kit to Indoor Unit

Example: Recommended From each Indoor Unit to Multi-Kit, use hard copper pipes that bend to prevent kinking.

Hard Copper Piping will expand and contract


due to temperature changes in piping. Multi-Kit Connection Pipe
Bending Pipe
NOTICE:
Outdoor Unit When on-site piping is installed using
soft or hard copper, make sure that the
piping is installed to allow for movement
Indoor Unit of the piping. Temperature changes cause
Multi-Kit contraction and expansion of the piping.
Install Horizontally

[ Fixing for Liquid Piping, Low Pressure Gas Piping and High/Low Pressure Gas Piping ]

Low Pressure
Gas Piping Installing Part for Piping

High/Low Pressure
Gas Piping NOTICE:
Due to the properties of hard copper piping,
expansion and contraction take place during
seasons of heat and cold. Do not strap gas
Liquid Piping refrigerant and piping containing liquids together
as kinks.

Example: Not Recommended

Hard Copper Piping will expand and contract due to


temperature changes in piping.
Straight piping does not allow for movement of the piping when it expands or contracts.
Outdoor Unit

4.3 Connection Procedure for Piping Joint


When connecting liquid piping for the unit with a capacity 2.0HP or smaller, and when the length of piping is 15m
or longer, use a piping diameter size of f9.52mm. Secure the connecting pipe as shown below. Use the insulation
attached to the indoor unit.

Expander for Liquid Line (Accessory)


Use the flare nut of the indoor unit. Flare the pipe after inserting the flare nut.

Insulate this part with


the attached insulation.

Fix this part with the attached


Indoor
cord band or field-supplied vinyl tape.
Unit

Field-Supplied Refrigerant Piping


Insulation Attached to Indoor Unit Brazing
Field-Supplied Insulation

4.4 Piping Work


(1) When the branched pipe size is 22.2mm or less in inner diameter, a field-supplied mini-copper tube cutter is
required.
(mm)
Recommended Mini-Copper Tube Cutter Available Cut Size Rotating Radius

(21)
(43)

f5 - 28 (50)

(70)
70 or less

FAN-2209 201709 2-103


MULTI-KIT

(2) Use clean copper pipes without any moisture or foreign materials on inner surface of pipes. When
connecting refrigerant pipe, cut the copper pipes with a copper tube cutter as shown below. Also deburr
the cutting edge using deburring tool to ensure that no burr goes inside the pipe. Blow-out the pipes with
nitrogen or compressed air to ensure that no dust remains inside the pipe. Do NOT use a saw, a grindstone
or other tools which causes a large amount of powder residue when cutting.

Copper Tube Cutter

Pipe

Deburring
Connection
Part

(3) When cutting the pipe, allow for an adequate depth for brazing as shown in the following table.

(mm)
Diameter Min. Insertion Depth
B
(A) (B)
Over 5, Below 8 6
Over 8, Below 12 7
Over 12, Below 16 8

A
Over 16, Below 25 10
Over 25, Below 35 12
Total Straight Section
Over 35, Below 45 14 Min. 500mm

● Caution for Refrigerant Piping

When installing pipe through the Do NOT place the pipe directly In case of rain attach a cap or
wall, secure a cap at the end of on the ground. put a plastic bag over the pipe end.
the pipe.
INCORRECT CORRECT INCORRECT CORRECT INCORRECT
Hole
Attach a cap Rain water
or plastic bag can enter.
Attach a cap with rubber
Attach a cap or vinyl tape. band.
or vinyl tape.
CORRECT

(4) Make sure that all stop valves for the outdoor unit are closed completely.
(5) Blow-out the inside of the pipes with nitrogen gas before brazing. Bleed nitrogen gas through piping during
brazing. Pressure not to exceed 0.02MPa.

Make sure that a test for leakage of refrigerant gases has been performed. The refrigerant used for this
unit (HFC R410A), is a non-flammable, non-toxic, and odorless gas. However if refrigerant should leak
and make contact with sparks, and catch on fire, toxic gas will be generated. Fluorocarbon, which is
heavier than air, will form on the floor surface and could cause suffocation.

(6) The airtight test pressure for this product is 4.15MPa.


(7) Install the field-supplied insulation with these multi-kits to each branch (liquid side and gas or vapor side),
with tape. Also, apply the field-supplied insulation for these units.

2-104 FAN-2209 201709


MULTI-KIT

NOTICE
When polyethylene foam is applied, a thickness of 10mm for liquid piping and 15 to 20mm for gas piping is
recommended. (Use a grade of insulation with heat resistance of 100ºC for gas piping.)

Wrap insulation tape between the accessory


Insulation insulation and the field-supplied insulation.
(Field-Supplied) There should be no gaps showing.
Insulation for Gas and
Liquid Line (Accessory)
Do not leave any gaps Insulation
between layers of insulation. (Field-Supplied)

Insulation Tape
(Field-Supplied)
After positioning all insulation with tape,
follow up and secure it permanently
with a second application of tape.

● Perform insulation work only when the surface temperature of the pipe material has cooled to room
temperature. Anything done immediately after brazing can cause insulation to melt.
● During piping work, always cover over or plug the open end to keep the inside free of dust and moisture.

After installation, it is recommended that the customer retain this manual for future reference.

© 2017 Johnson Controls-Hitachi Air Conditioning Technology (Hong Kong) Ltd.

P5416979, 2017

FAN-2209 201709 2-105


MULTI-KIT

Installation Manual for Multi-Kits


Line Branch Models: MW-NP282A3, MW-NP452A3, MW-NP692A3, MW-NP902A3

NOTE
Hand over this installation manual to the next installation work personal.

1. Applicable Outdoor Units


These multiple line branches can be applied to the R410A VRF systems.

2. Transportation
Transport the product as close to the installation location as practical before unpacking.

Do not put any material on the product.

3. Before Installation
Confirm the number of the following parts by referring to the model printed on the package before unpacking.
Do NOT put any foreign material into the parts. Check to confirm that no foreign materials are inside the parts
before installation.

NOTICE:
If any of these parts are missing, please contact your distributor. Do not discard any foam packaging as it is
used as insulation for the joint kits after pressure testing is complete.
Model MW-NP282A3 MW-NP452A3 MW-NP692A3 MW-NP902A3
Name of Parts Qty. Qty. Qty. Qty.

Branch Pipe for


High/Low Pressure
Gas Line
1 1 1 1

Branch Pipe for


Liquid Line

1 1 1 1

Insulation for
High/Low Pressure
Gas Line
1 set 1 set 1 set 1 set

Insulation for
Liquid Line
1 set 1 set 1 set 1 set
Accessory

Reducer for
High/Low Pressure Gas None 1 1 1
Line Connection
(For Connecting Pipe
(Field-Supplied))
None None None 1
Reducer for
Liquid Line Connection
(For Connecting Pipe
(Field-Supplied)) 2 1 1 1

Tape
2 2 2 2

P5416978

2-106 FAN-2209 201709


MULTI-KIT

4. Installation Work
4.1 Piping Connection Size
The ends of the multi-kits are finished as shown in the following figures. Cut the end of the pipe to correspond to
the pipe size.

Allow adequate space for elbow, angled, and irregular piping arrangements to compensate for expansion
and contraction brought on by temperature change.

Unit: mm, ID: Inner Diameter, OD: Outer Diameter


Reducer for
Branch Pipe for Branch Pipe for Reducer for
Model High/Low Pressure
High/Low Pressure Gas Line Liquid Line Liquid Line
Gas Line

(To Main Piping)


(To Main Piping)
ID 12.7
ID 22.2 ID 6.35
ID 15.88
ID 19.05 ID 9.52 ID 9.52
ID 19.05
ID 15.88 ID 22.2 ID 9.52

MW-NP282A3
ID 9.52
ID 19.05 OD 6.35
ID 6.35
ID 15.88
(To Outdoor Unit) (To Indoor Unit)
ID 12.7 (To Outdoor Unit)
(To Indoor Unit)
(Qty. 2)

(To Main Piping) (To Main Piping)


ID 28.58
ID 28.58 ID 9.52
ID 25.4
ID 12.7 ID 12.7 ID 25.4
ID 22.2
OD 28.58 ID 15.88 ID 9.52

MW-NP452A3 ID 12.7
ID 22.2
ID 22.2 ID 12.7
(To Outdoor Unit) ID 9.52
ID 19.05 OD 6.35
ID 6.35 ID 19.05

ID 15.88 (To Outdoor Unit)

ID 12.7 (To Indoor Unit)


(To Indoor Unit)

(To Main Piping) (To Main Piping)


ID 28.58 ID 15.88
ID 9.52
ID 28.58 ID 19.05
ID 25.4 ID 12.7
ID 22.2 ID 22.2 ID 15.88
ID 25.4
ID 9.52
OD 28.58 ID 15.88

MW-NP692A3 ID 22.2
ID 15.88
(To Outdoor Unit) ID 19.05 ID 22.2 ID 12.7
OD 6.35
ID 12.7
ID 6.35 ID 19.05
ID 15.88 ID 9.52

ID 12.7 (To Outdoor Unit)


(To Indoor Unit)
(To Indoor Unit)

(To Main Piping) (To Main Piping) ID 25.4


OD 31.75
ID 38.1 ID 15.88 ID 12.7 ID 22.2

ID 31.75 ID 34.93 ID 19.05 ID 15.88

ID 38.1 ID 31.75 ID 22.2 ID 19.05 ID 28.58


ID 22.2 ID 9.52

MW-NP902A3
ID 9.52 ID 25.4
(To Outdoor Unit) OD 28.58 ID 15.88 OD 6.35
(To Outdoor Unit) ID 15.88
ID 28.58 ID 12.7

ID 9.52 ID 22.2 ID 12.7


(To Indoor Unit) (To Indoor Unit) ID 6.35
ID 19.05

FAN-2209 201709 2-107


MULTI-KIT

4.2 Installation Position


(1) Horizontal Installation
Locate the “Y” union pipe section on the same horizontal plane. (Inclination within 30o)
Make the straight section a minimum of 500mm after the vertical bend.

Upward
Total Straight Section
Inclination
Min. 500mm within 30o

o
30
Horizontally
Downward A Inclination
(View from A)
INCORRECT

(2) Vertical Installation


Straight section of the pipe connection on the outdoor unit side is made as follows:
a) The collective pipe connection part is installed upward; the straight section must be a minimum of
500mm.
b) The collective pipe connection part is installed downward; the straight section must be a minimum of
500mm.

Upward

Total Straight Section


Min. 500mm

Total Straight Section


Min. 500mm

Downward

(3) Piping from Multi-Kit to Indoor Unit

Example: Recommended From each Indoor Unit to Multi-Kit, use hard copper pipes that bend to prevent kinking.

Hard Copper Piping will expand and contract due


to temperature changes in piping. Multi-Kit Connection Pipe
Bending Pipe NOTICE:
When on-site piping is installed using
Outdoor Unit soft or hard copper, make sure that the
piping is installed to allow for movement
of the piping. Temperature changes cause
Multi-Kit Indoor Unit contraction and expansion of the piping.
Install Horizontally

[ Fixing for Liquid Piping, Low Pressure Gas Piping and High/Low Pressure Gas Piping ]

High/Low Pressure
Gas Piping Installing Part for Piping

NOTICE:
Due to the properties of hard copper piping,
expansion and contraction take place during
seasons of heat and cold. Do not strap gas
Liquid Piping
refrigerant and piping containing liquids together
as kinks.

Example: Not Recommended

Hard Copper Piping will expand and contract due to


temperature changes in piping.
Straight piping does not allow for movement of the piping when it expands
or contracts.
Outdoor Unit

2-108 FAN-2209 201709


MULTI-KIT

4.3 Connection Procedure for Piping Joint


When connecting liquid piping for the unit with a capacity 2.0HP or smaller, and when the length of piping is 15m
or longer, use a piping diameter size of f9.52mm. Secure the connecting pipe as shown below. Use the insulation
attached to the indoor unit.

Expander for Liquid Line (Accessory)


Use the flare nut of the indoor unit. Flare the pipe after inserting the flare nut.

Insulate this part with


the attached insulation.

Fix this part with the attached


Indoor
cord band or field-supplied vinyl tape.
Unit

Field-Supplied Refrigerant Piping


Insulation Attached to Indoor Unit Brazing
Field-Supplied Insulation

4.4 Piping Work


(1) When the branched pipe size is 22.2mm or less in inner diameter, a field-supplied mini-copper tube cutter is
required.
(mm)
Recommended Mini-Copper Tube Cutter Available Cut Size Rotating Radius

(21)
(43)

f5 - 28 (50)

(70)
70 or less

(2) Use clean copper pipes without any moisture or foreign materials on inner surface of pipes. When
connecting refrigerant pipe, cut the copper pipes with a copper tube cutter as shown below. Also deburr
the cutting edge using deburring tool to ensure that no burr goes inside the pipe. Blow-out the pipes with
nitrogen or compressed air to ensure that no dust remains inside the pipe. Do NOT use a saw, a grindstone
or other tools which causes a large amount of powder residue when cutting.

Copper Tube Cutter

Pipe

Deburring
Connection
Part

(3) When cutting the pipe, allow for an adequate depth for brazing as shown in the following table.

(mm)
Diameter Min. Insertion Depth
(A) (B) B
Over 5, Below 8 6
Over 8, Below 12 7
Over 12, Below 16 8
A

Over 16, Below 25 10


Over 25, Below 35 12
Over 35, Below 45 14

FAN-2209 201709 2-109


MULTI-KIT

● Caution for Refrigerant Piping

When installing pipe through the Do NOT place the pipe directly In case of rain attach a cap or
wall, secure a cap at the end of on the ground. put a plastic bag over the pipe end.
the pipe.
INCORRECT CORRECT INCORRECT CORRECT INCORRECT
Hole
Attach a cap Rain water
or plastic bag can enter.
Attach a cap with rubber
Attach a cap or vinyl tape. band.
or vinyl tape.
CORRECT

(4) Make sure that all stop valves for the outdoor unit are closed completely.
(5) Blow-out the inside of the pipes with nitrogen gas before brazing. Bleed nitrogen gas through piping during
brazing. Pressure not to exceed 0.02MPa.

Make sure that a test for leakage of refrigerant gases has been performed. The refrigerant used for this
unit (HFC R410A), is a non-flammable, non-toxic, and odorless gas. However if refrigerant should leak
and make contact with sparks, and catch on fire, toxic gas will be generated. Fluorocarbon, which is
heavier than air, will form on the floor surface and could cause suffocation.

(6) The airtight test pressure for this product is 4.15MPa.


(7) Install the field-supplied insulation with these multi-kits to each branch (liquid side and gas or vapor side),
with tape. Also, apply the field-supplied insulation for these units.

NOTICE
When polyethylene foam is applied, a thickness of 10mm for liquid piping and 15 to 20mm for gas piping is
recommended. (Use a grade of insulation with heat resistance of 100ºC for gas piping.)

Wrap insulation tape between the accessory


Insulation insulation and the field-supplied insulation.
(Field-Supplied) There should be no gaps showing.
Insulation for Gas and
Liquid Line (Accessory)
Do not leave any gaps Insulation
between layers of insulation. (Field-Supplied)

Insulation Tape
(Field-Supplied)
After positioning all insulation with tape,
follow up and secure it permanently
with a second application of tape.

● Perform insulation work only when the surface temperature of the pipe material has cooled to room
temperature. Anything done immediately after brazing can cause the insulation to melt.
● During piping work, always cover over or plug the open end to keep the inside free of dust and moisture.

After installation, it is recommended that the customer retain this manual for future reference.

© 2017 Johnson Controls-Hitachi Air Conditioning Technology (Hong Kong) Ltd.

P5416978, 2017

2-110 FAN-2209 201709


MULTI-KIT

Installation Manual for Multi-Kits


Header Branch Model: JMH-NP288X

NOTE
Hand over this installation manual to the next
installation work personnel. Do not put any material on the product.

1. Applicable Outdoor Units 3. Before Installation


These multiple pipe connecting kits can be applied to Confirm the number of the following parts by
the R410A VRF systems. referring to the model printed on the package before
unpacking.
2. Transportation Do NOT put any foreign material into the parts.
Check to confirm that no foreign materials are inside
Transport the product as close to the installation
the parts before installation.
location as practical before unpacking.

Name of Parts JMH-NP288X


Q’ty

Branch Pipe for


Low Pressure Gas Line
1

Branch Pipe for


High Pressure Gas Line
1

Branch Pipe for Liquid Line


1

Insulation for
Low Pressure Gas Line
1

Insulation for
High Pressure Gas Line
1

Insulation for Liquid Line


1
For Gas Line For Liquid Line For Liquid Header
f12.7 f6.35 f9.52
Closing Pipe
12 6 1
Accessory

OD15.88 x ID19.05
Expander for
Low Pressure Gas Line 2
OD15.88 x ID12.7 OD12.7 x ID9.52
Expander for
High Pressure Gas Line 1 8
OD6.35 x ID9.52
Expander for Liquid Line
10

Insulation for Closing Pipe


12

Insulation for Liquid Pipe


8

Tape
62
Unit: mm, ID: Inner Diameter, OD: Outer Diameter

NOTE : If any of these parts is not contained, please contact your distributor.

FAN-1593 201607

FAN-2209 201709 2-111


MULTI-KIT

4. Installation Work
4.1 Piping Connection Size
The ends of the multi-kits are finished as shown in
the following figures. Cut the end of the pipe to meet Piping shall be supported with adequate space.
with the pipe size. Bent pipes and bypass piping (horizontal loop)
shall also be installed in order to absorb piping
elasticity caused by temperature changes.

Name of Parts JMH-NP288X

ID19.05
ID15.88 ID22.2 φ22.2

Low Pressure Gas Line

ID15.88 φ15.88
ID12.7

ID19.05
ID15.88 ID22.2 φ22.2

High Pressure Gas Line

ID15.88 φ15.88
ID12.7

φ19.05

ID9.52
φ9.52
Liquid Line
ID9.52 ID6.35 φ9.52
(For Closing)

(For Low Pressure Gas Line) (For High Pressure Gas Line) (For Liquid Line)

OD12.7 ID9.52

Expander Q’ty: 8 (For End of Multi-Kit Connection) OD6.35 ID9.52


OD15.88 ID19.05

OD15.88 ID12.7 Q’ty: 10


Q’ty: 2 (For End of Multi-Kit Connection)
2: For End of Multi-Kit Connection
Q’ty: 1 (For End of Multi-Kit Connection) 8: For Unit Piping Connection
(For Low Pressure Gas Line) (For High Pressure Gas Line) (For Liquid Line)

Closing Pipe
OD12.7 OD12.7 OD6.35

Q’ty: 6 Q’ty: 6 Q’ty: 6

Unit: mm, ID: Inner Diameter, OD: Outer Diameter

4.2 Installation Position


Perform to install horizontally always.
Horizontally

Gas Piping Side


Horizontally

Liquid Piping Side

2-112 FAN-2209 201709


MULTI-KIT

4.3 Connection Procedure for Piping Joint


When connecting liquid piping for the unit with a capacity 2.0HP or smaller, and with the length of piping is
15 meters or longer, apply the piping size of f9.52mm. Fix the connecting pipe as shown in the below figure.
Use the insulation attached to the indoor unit.
Expander for Liquid Line (Accessory)
Flare the pipe after inserting the flare nut.
Use the flare nut of the indoor unit. Fix this part with the attached cord
band or field-supplied vinyl tape.
Insulate this part with the
attached insulation.
Indoor
Unit
Field-Supplied Refrigerant Piping

Insulation Attached to Indoor Unit Brazing Field-Supplied Insulation

4.4 Piping Connection


(1) Use clean copper pipes without any moisture ● Caution for Refrigerant Piping
or foreign materials on inner surface of pipes.
When installing pipe through the Do NOT place the pipe directly
When connecting refrigerant pipe, cut the wall, secure a cap at the end of on the ground.
copper pipes with a pipe cutter as shown the pipe.
INCORRECT CORRECT INCORRECT
below.
Hole
Also blow the pipes with nitrogen or air to
remain no dust inside the pipe. Attach a cap
Attach a cap or vinyl tape.
Do NOT use a saw, a grindstone or others or vinyl tape.
CORRECT
which causes a large amount of cutting
powder. CORRECT INCORRECT
Attach a cap Rain water
Pipe Cutter or vinyl tape can enter.
with rubber
Pipe band.

Deburring
(3) Make sure that all stop valves of the outdoor
Connection unit are closed completely.
Part
(4) Blow the inside of the pipes with nitrogen gas
when brazing.
(2) When cutting the pipe, secure the adequate
depth for brazing as shown in the following
table.
(mm)
Check for the refrigerant leakage carefully.
A: Outer Diameter B: Minimum Depth If large amount of refrigerant leakage occurs,
Over 5, Below 8 6 it will cause to breathe with difficulty or to
Over 8, Below 12 7 generate harmful gas due to the fire.
Over 12, Below 16 8
Over 16, Below 25 10 (5) The air tight test pressure of this product is
4.15MPa.
Over 25, Below 35 12
Over 35, Below 45 14
(6) Apply the insulation supplied with this multi-kits
to each branch (liquid side and gas side) with a
B tape. Also apply the field-supplied insulation to
the field-supplied pipes.

NOTE
A

When polyethylene foam is applied, a thickness of


10mm for liquid piping and 15mm to 20mm for gas
piping is recommended. (Use the insulation with
heat resistance of 100oC for gas piping.)

FAN-2209 201709 2-113


MULTI-KIT

For Gas Side For Liquid Side


a) Cover the gas header with the insulation as shown a) Braze the closing pipe (accessory) to the connection
below. part at the reversed side against the field-piping.
Cover the liquid header with the insulation after
the pipe temperature decreases to the room
temperature.

Header for Tape


Insulation
Gas Line (Accessory)
(Accessory)
Header for Insulation Tape
Liquid Line
(Accessory) (Accessory)
Closing Pipe for Liquid Line Header

b) Seal the joint part of insulation with a tape b) Cut the insulation for liquid pipe as many as
(accessory). required to attach for the joint part.
Tape Tape
(Accessory) (Accessory)
Insulation for
Header Multi-Kit
(Accessory)

Cut off as many as


required for field Insulation for Liquid
Insulation Pipe Adjusted for
connection.
(Field-Supplied) Attaching (Accessory)

c) Attach the insulation (accessory) onto the closing c) Seal the joint part of the closing pipe with a tape
pipe. Then seal the joint part with a tape (accessory). (accessory) after attaching the liquid pipe insulation.
Insulation for Gas
Line Closing Pipe
(Accessory) Tape
(Accessory)

Closing Pipe Tape


(Accessory) (Accessory) Closing Pipe
(Accessory)

● Caution for Installation


Branch Pipe for Gas Line Branch Pipe for Liquid Line
Install the branch pipe horizontally by placing it on the Suspend the branch pipe from the ceiling so that the
platform. branch pipe port openings are horizontal.
Ceiling Ceiling
Suspension
Bracket
(Field-Supplied)
Horizontally

Horizontally

Platform (Field-Supplied)

● Perform the insulation work when the pipe surface temperature decreases to the room temperature.
If insulation work is performed immediately after brazing, insulation may melt.
● If the ends of pipe are open to the atmosphere for a while after performing piping work, securely put
caps or plastic bags over the pipe ends for avoiding moisture or dust.

After installation, it is recommended to keep this manual by a customer.

© 2016 Johnson Controls, Inc. www.johnsoncontrols.com Form FAN-1593 201607

Johnson Controls reserve the right change product features without notice. P5416738

2-114 FAN-2209 201709


MULTI-KIT

Installation Manual for Multi-Kits


Header Branch Models: JMH-NP224A, JMH-NP288A

NOTE
Hand over this installation manual to the next
installation work personnal. Do not put any material on the product.

1. Applicable Outdoor Units 3. Before Installation


These multiple pipe connecting kits can be applied to Confirm the number of the following parts by
the R410A VRF systems. referring to the model printed on the package before
unpacking.
Do NOT put any foreign material into the parts.
2. Transportation Check to confirm that no foreign materials are inside
Transport the product as close to the installation the parts before installation.
location as practical before unpacking.

Name of Parts JMH-NP224A JMH-NP288A


Q'ty Q'ty

Branch Pipe
for Gas Line
1 1

Branch Pipe
for Liquid Line
1 1
Insulation
for Gas Line
1 1

Insulation
for Liquid Line
1 1
For Gas Line For Liquid Line For Liquid Header For Gas Line For Liquid Line For Liquid Header
Closing φ12.7 φ6.35 φ9.52 φ12.7 φ6.35 φ9.52
Pipe
2 2 1 6 6 1
Accessories

Expander
for Gas Line
None 2

Expander
for Liquid Line
4 8
Insulation for
Closing Pipe
2 sets 6 sets

Insulation for
Liquid Line
4 sets 8 sets

Tape
24 48

NOTE : If any of these parts is not contained, please contact your distributor.

FAN-1591 201607

FAN-2209 201709 2-115


MULTI-KIT

4. Installation Work
4.1 Piping Connection Size
The ends of the multi-kits are finished as shown in
the following figures. Cut the end of the pipe to meet
Piping shall be supported with adequate space.
with the pipe size.
Bent pipes and bypass piping (horizontal loop)
shall also be installed in order to absorb piping
elasticity caused by temperature changes.

Models Gas Line Liquid Line Expander Closing Pipe


(For Gas Line)

φ19.05

ID15.88
OD12.7
ID19.05 φ19.05 φ9.52

φ9.52
ID9.52
Q'ty: 2
JMH-NP224A
ID6.35 (For Liquid Line) (For Liquid Line)
ID9.52
φ15.88 ID9.52
ID15.88
ID12.7
OD6.35 OD6.35
φ9.52
(For Closing)
Q'ty: 4 Q'ty: 2
(For Gas Line) (For Gas Line)

ID19.05
ID15.88 φ19.05
ID19.05
OD12.7
ID22.2 φ22.2 OD15.88
φ9.52
ID9.52
Q'ty: 2 Q'ty: 6
JMH-NP288A
ID9.52 (For Liquid Line) (For Liquid Line)
φ15.88
ID6.35
ID15.88 ID9.52
ID12.7

OD6.35 OD6.35
φ9.52
(For Closing)

Q'ty: 8 Q'ty: 6

Unit: mm, ID: Inner Diameter, OD: Outer Diameter

4.2 Installation Position


Perform to install horizontally always.
(Ex.: In Case of Model JMH-NP288A)
Horizontally

Gas Piping Side


Horizontally

Liquid Piping Side

2-116 FAN-2209 201709


MULTI-KIT

4.3 Connection Procedure for Piping Joint


When connecting liquid piping for the unit with a capacity of 2.0HP or smaller, and with the length of piping is 15
meters or longer, apply the piping size of f9.52mm. Fix the connecting pipe as shown in the below figure.
Use the insulation attached to the indoor unit.

Expander for Liquid Line (Accessory)


Flare the pipe after inserting the flare nut.
Use the flare nut of the indoor unit. Fix this part with the attached cord
band or field-supplied vinyl tape.
Insulate this part with the
attached insulation.
Indoor
Unit
Field-Supplied Refrigerant Piping

Insulation Attached to Indoor Unit Brazing Field-Supplied Insulation

4.4 Piping Connection


(1) Use clean copper pipes without any moisture ● Caution for Refrigerant Piping
or foreign materials on inner surface of pipes.
When connecting refrigerant pipe, cut the copper When installing pipe through the Do NOT place the pipe directly
wall, secure a cap at the end of on the ground.
pipes with a pipe cutter as shown below. the pipe.
Also blow the pipes with nitrogen or air to remain INCORRECT CORRECT INCORRECT
no dust inside the pipe. Hole
Do NOT use a saw, a grindstone or others which
Attach a cap
causes a large amount of cutting powder. Attach a cap
or vinyl tape.
or vinyl tape.
CORRECT

Pipe Cutter
CORRECT INCORRECT
Pipe Attach a cap Rain water
or vinyl tape can enter.
with rubber
band.

Deburring
Connection
Part
(3) Make sure that all stop valves of the outdoor unit
are closed completely.
(4) Blow the inside of the pipes with nitrogen gas
(2) When cutting the pipe, secure the adequate when brazing.
depth for brazing as shown in the following table.
(mm)
A: Outer Diameter B: Minimum Depth Check for the refrigerant leakage carefully. If
Over 5, Below 8 6 large amount of refrigerant leakage occurs, it will
Over 8, Below 12 7 cause to breathe with difficulty or to generate
Over 12, Below 16 8 harmful gas due to the fire.
Over 16, Below 25 10
Over 25, Below 35 12 (5) The air tight test pressure of this product is
Over 35, Below 45 14
4.15MPa.
(6) Apply the insulation supplied with this multi-kits
to each branch (liquid side and gas side) with a
B
tape. Also apply the field-supplied insulation to
the field-supplied pipes.

NOTE
A

When polyethylene foam is applied, a thickness of


10mm for liquid piping and 15mm to 20mm for gas
piping is recommended. (Use the insulation with
heat resistance of 100ºC for gas piping.)

FAN-2209 201709 2-117


MULTI-KIT

For Gas Side For Liquid Side


a) Cover the gas header with the insulation as shown a) Braze the closing pipe (accessory) to the connection
below. part at the reversed side against the field-piping.
Cover the liquid header with the insulation after
the pipe temperature decreases to the room
temperature.

Header for Tape


Insulation
Gas Line (Accessory)
(Accessory)
Header for Insulation Tape
Liquid Line
(Accessory) (Accessory)
Closing Pipe for Liquid Line Header

b) Seal the joint part of insulation with a tape b) Cut the insulation for liquid pipe as many as
(accessory). required to attach for the joint part.
Tape Tape
(Accessory) (Accessory)
Insulation for
Header Multi-Kit
(Accessory)

Cut off as many as


required for field Insulation for Liquid
Insulation connection. Pipe Adjusted for
(Field-Supplied) Attaching (Accessory)

c) Attach the insulation (accessory) onto the closing c) Seal the joint part of the closing pipe with a tape
pipe. Then seal the joint part with a tape (accessory). (accessory) after attaching the liquid pipe insulation.
Insulation for Gas
Line Closing Pipe
(Accessory) Tape
(Accessory)

Closing Pipe Tape


Closing Pipe
(Accessory) (Accessory)
(Accessory)

● Caution for Installation


Branch Pipe for Gas Line Branch Pipe for Liquid Line
Install the branch pipe horizontally by placing it on the Suspend the branch pipe from the ceiling so that the
platform. branch pipe port openings are horizontal.
Ceiling Ceiling
Suspension
Bracket
(Field-Supplied)
Horizontally

Horizontally

Platform (Field-Supplied)

● Perform the insulation work when the pipe surface temperature decreases to the room temperature.
If insulation work is performed immediately after brazing, insulation may melt.
● If the ends of pipe are open to the atmosphere for a while after performing piping work, securely put
caps or plastic bags over the pipe ends for avoiding moisture or dust.

After installation, it is recommended to keep this manual by a customer.

© 2016 Johnson Controls, Inc. www.johnsoncontrols.com Form FAN-1591 201607


Johnson Controls reserve the right change product features without notice.
P5416736

2-118 FAN-2209 201709


DRAIN BOSS

Installation
HITACHI Manual
Installation for Drain
Manual Boss
for Multi-Kits
Drain Model:
Boss Model: DBS-TP10A
DBS-TP10A

NOTE
This drain boss is for the drain pipe connection in order to use outdoor unit bottom base as a drain pan.

1. Applicable Outdoor Units


NOTE:
Applicable Outdoor Unit HP Make sure to check the series of the applicable
Top Flow Type 5 to 54 outdoor units as well as the specified quantity of the
drain boss in the catalog.

2. Before Installation
Confirm the number of the following parts by referring to the model printed on the package before unpacking.

No. Parts Name Q'ty Application

Drain Boss 43
1 2 Connecting for Drain Piping
(VP20 Equivalent) Outer Diameter φ 25
(Inner Diameter φ 20)

2 Rubber Cap 4 Fixing for 1 Boss and 3 Cap

3 Drain Cap 2 Embolization for Drain Hole

3. Installation Work

Place the outdoor unit on the flat foundation or block and fix it at least 100mm higher than the ground.
For smooth drainage, install the outdoor unit with slightly inclined on the drainage side (rear side).

3.1 Installation of Drain Boss


The drain boss is for the drain pipe connection in order to use Projection
Hole for Drain Boss
outdoor unit bottom base as a drain pan. 1 Drain Boss

(1) Put the 2 rubber cap in the 1 drain boss (to the upper part of Drain Boss
the drain boss projection) in the arrow direction. 2 Rubber Cap (1,2)

(2) Put the drain boss in the hole for the drain boss of the outdoor
unit bottom base until it is securely fixed. (approx. 40o)
(The drain boss in the shape of taper can be fit into the bottom base and stopped by itself.)
3.2 Installation of Drain Cap
The drain cap is a component to cover a hole.
(The hole for drain boss of the outdoor unit is not included.) Projection Hole for Drain Boss

(1) Put the 2 rubber cap in the 3 drain cap (to the upper part of 3 Drain Cap

the drain boss projection) in the arrow direction. 2 Rubber Cap Drain Cap
(2,3)
(2) Put the drain cap in the hole for the drain boss of the outdoor
o
unit bottom base until it is securely fixed. (approx. 40 )
(The drain cap in the shape of taper can be fit into the bottom base and stopped by itself.)

Use a rubber cap when fixing the drain boss and drain cap. (No rubber cap may lead to water leakage.)
After fixing, ensure that there is no water leakage from the drain cap after pouring water into the bottom
base and then draining it from the drain boss.

P5414717

FAN-2209 201709 2-119


DRAIN BOSS

< Installation Position >


Example
Model: 5HP
(169)
< Side View >
(91)

2 3 Drain Cap Position (2 places) (Rear Side)

52
(Front Side)

125
(73) Bottom Base

1 2 Drain Boss Position (1 Place) 2 3 Drain Cap


(Outdoor Unit Rear Side)
Drain Pipe 1 2 Drain Boss
(Field-Supplied)

Model: 8HP

(247) < Side View >


(91)
2 3 Drain Cap Position (2 places)
(Rear Side)
52
(Front Side)
125

Bottom Base
(73)
2 3 Drain Cap
1 2 Drain Boss Position (2 Places)
Drain Pipe
(Outdoor Unit Rear Side) 1 2 Drain Boss
(Field-Supplied)

Securely fix the drain boss, rubber cap and drain cap at the bottom base without being loosened when
connecting the drain pipe.

4. Utilization in Cold Area

Do not use drain boss kit in an area where drain water may be frozen.
(The drain water in the drain pipe may be frozen and then the drain pipe may crack.)

(1) In a snow area, water from the heat exchanger may be frozen on the surface of the bottom base. This may
lead to poor drainage. Therefore, do not use the drain boss kit in this area.
(2) In the drainage method according to this manual, some of the defrost drain water dripped from the inlet
protection grille may be flowed out over the bottom base of the product.
To prevent this, provide a drain pan larger than the bottom surface of the product. Fix the drain pan and the
discharge pipe between the bottom part of the product and the foundation prior to discharge.

P5414717

2-120 FAN-2209 201709


AIR INLET GRILLE

Installation Manual for Air Inlet Grille


(for Rear Side Installation of Outdoor Unit)
Model: PSN-TP20BA
PSN-TP20BB

This air inlet grille is to caution not to touch the outdoor unit heat exchanger reaching from air inlet. It is not
designed to prevent people reaching to the heat exchanger. Install it as instructed in this manual.

IMPORTANT NOTICE:
● Read and understand this manual before using this air inlet grille.
● Perform the test run after installation to check for abnormalities.
● Forward this information to the building owner and request that they maintain all the equipment manuals.
● Signal words are used to identify levels of hazard seriousness.
Definitions for identifying hazard levels are provided below with their respective signal words.

: Indicates a hazardous situation that, if not avoided,


could result in minor or moderate injury.

1. Applicable Unit
NOTICE:
The applicable outdoor unit may be different depending on the product series. Be sure to confirm with the
product catalog before installation.

Name Air Inlet Grille (for Rear Side Installation)


Model PSN-TP20BA PSN-TP20BB
Required Qty. 1 1
Heat RAS-8 - 12FSNS, RAS-5, 6FSNP RAS-14 - 18FSNS, RAS-8 - 14FSNP
Applicable Outdoor Unit Pump JTOH080 - 120VPE(U,F,R)BS1 JTOH140 - 180VPE(U,F,R)BS1
(Representative Model) Heat RAS-8 - 12FSXNS, RAS-5, 6FSXNP RAS-14 - 18FSXNS, RAS-8 - 14FSXNP
Recovery JTOR080 - 120VPE(U,F,R)BS1 JTOR140 - 180VPE(U,F,R)BS1

2. Installation Work
(1) Be sure to securely tighten the air inlet grille with the supplied screws (accessories).
If the screws are not securely tightened, it may cause vibration or abnormal sound.
If they are over-tightened, the screw threads may be stripped. When tightening the screws, make sure
to follow the tightening torque below.
● Tightening Torque: 2.0+0.5 N●m
(2) Secure enough service space with consideration for attaching/detaching the air inlet grille.
● Service Space with Air Inlet Grille: Service Space for Outdoor Unit + Min. 150mm
(3) The air inlet grille may accumulate ice or snow during cold weather.
(4) Apply touch-up coating to the screw fixing part on the outdoor unit to prevent rust formation (local
supply).

FAN-2209 201709 2-121


AIR INLET GRILLE

3. Before Installation
Check that all the following accessories are packed with the unit before installation.
Unit: mm
Qty.
No. Accessory Remarks
PSN-TP20BA PSN-TP20BB

852 1 -
Air Inlet Grille
1 (for Rear Side a
Installation) 1227

a
1112 - 1

( ) indicate
2
M5 x 12L 11 11
Screw the number of
(with Washer) (1) (1)
spare part

3
Self-Tapping M4 x 13L
2 2 for drilling
Screw (without Washer)

4. Installation Procedures
Before installation, confirm the outdoor unit model. If the air inlet grille is available for your model, follow the
installation procedures.

(1) Open holes on rear side the outdoor unit ( P x 2) using the self-tapping screw 3 .

Unit: mm
a 287 Outdoor Unit
a
(Representative Model)
RAS-8 - 12FSNS, RAS-5, 6FSNP
P RAS-8 - 12FSXNS, RAS-5, 6FSXNP
330
JTOH080 - 120VPE(U,F,R)BS1
119

JTOR080 - 120VPE(U,F,R)BS1
RAS-14 - 18FSNS, RAS-8 - 14FSNP
RAS-14 - 18FSXNS, RAS-8 - 14FSXNP
460
JTOH140 - 180VPE(U,F,R)BS1
JTOR140 - 180VPE(U,F,R)BS1

(2) Hook the “A” part (edges of air inlet grille) between the heat exchanger and bottom base of unit. Mount
the air inlet grille using the screws ( 2 x 10).

Enlarged View of “A”

1
Heat Exchanger
2
Air Inlet Grille

Bottom Base

Outdoor Unit
A
PSN-TP20BA: two places
PSN-TP20BB: three places

2-122 FAN-2209 201709


AIR INLET GRILLE

5. Installation Appearance

PSN-TP20BA Unit: mm

Screws
(Accessory)
Air Inlet Grille
[for Left Side
Installation]
Air Inlet Grille (Other Air Inlet

1675
[for Side Grille Option)
Installation]
(Other Air Inlet Air Inlet Grille
Grille Option) [for Rear Side
Installation]
Outdoor Unit
950 765

< Right Side > < Rear Side > < Left Side >

PSN-TP20BB

Screws
(Accessory)
Air Inlet Grille
[for Left Side
Installation]
Air Inlet Grille 1675 (Other Air Inlet
[for Side Grille Option)
Installation]
(Other Air Inlet Air Inlet Grille
Grille Option) [for Rear Side
Installation]
Outdoor Unit
1210 765

< Right Side > < Rear Side > < Left Side >

Available Combinations
Model
Heat RAS-8 - 12FSNS, RAS-5, 6FSNP RAS-14 - 18FSNS, RAS-8 - 14FSNP
Applicable Outdoor Unit
Pump JTOH080 - 120VPE(U,F,R)BS1 JTOH140 - 180VPE(U,F,R)BS1
(Representative Model)
Heat RAS-8 - 12FSXNS, RAS-5, 6FSXNP RAS-14 - 18FSXNS, RAS-8 - 14FSXNP
Recovery JTOR080 - 120VPE(U,F,R)BS1 JTOR140 - 180VPE(U,F,R)BS1

Air Inlet Grille for Rear Side PSN-TP20BA PSN-TP20BB

Air Inlet Grille for Left Side PSN-TP20L PSN-TP20R

Air Inlet Grille for Right Side PSN-TP20R

NOTICE:
● This manual applies only to the combination indicated with .
For other air inlet grille options, refer to each model’s installation manual.
● Install the required air inlet grille only if all installation requirements can be met.

© 2017 Johnson Controls-Hitachi Air Conditioning Technology (Hong Kong) Ltd.

P5416988-rev.1, 2017

FAN-2209 201709 2-123


AIR INLET GRILLE

Installation Manual for Air Inlet Grille


(for Rear Side Installation of Outdoor Unit)
Model: PSN-TP20BC

This air inlet grille is to caution not to touch the outdoor unit heat exchanger reaching from air inlet. It is not
designed to prevent people reaching to the heat exchanger. Install it as instructed in this manual.

IMPORTANT NOTICE:
● Read and understand this manual before using this air inlet grille.
● Perform the test run after installation to check for abnormalities.
● Forward this information to the building owner and request that they maintain all the equipment manuals.
● Signal words are used to identify levels of hazard seriousness.
Definitions for identifying hazard levels are provided below with their respective signal words.

: Indicates a hazardous situation that, if not avoided,


could result in minor or moderate injury.

1. Applicable Unit
NOTICE:
The applicable outdoor unit may be different depending on the product series. Be sure to confirm with the
product catalog before installation.

Name Air Inlet Grille (for Rear Side Installation)


Model PSN-TP20BC
Required Qty. 1
Heat RAS-20 - 24FSNS, RAS-16, 18FSNP
Applicable Outdoor Unit Pump JTOH200 - 240VPE(U,F,R)BS1
(Representative Model) Heat RAS-20 - 24FSXNS, RAS-16, 18FSXNP
Recovery JTOR200 - 240VPE(U,F,R)BS1

2. Installation Work
(1) Be sure to securely tighten the air inlet grille with the supplied screws (accessories).
If the screws are not securely tightened, it may cause vibration or abnormal sound.
If they are over-tightened, the screw threads may be stripped. When tightening the screws, make sure
to follow the tightening torque below.
● Tightening Torque: 2.0+0.5 N●m
(2) Secure enough service space with consideration for attaching/detaching the air inlet grille.
● Service Space with Air Inlet Grille: Service Space for Outdoor Unit + Min. 150mm
(3) The air inlet grille may accumulate ice or snow during cold weather.
(4) Apply touch-up coating to the screw fixing part on the outdoor unit to prevent rust formation (local
supply).

2-124 FAN-2209 201709


AIR INLET GRILLE

3. Before Installation
Check that all the following accessories are packed with the unit before installation.
Unit: mm
Qty.
No. Accessory Remarks
PSN-TP20BC

Air Inlet Grille


1 (for Rear Side 2
Installation) 1227

701

2 Stay 1

( ) indicate the
3
M5 x 12L 25
Screw number of spare
(with Washer) (1)
part

4
Self-Tapping M4 x 13L
3 for drilling
Screw (without Washer)

4. Installation Procedures
Before installation, confirm the outdoor unit model. If the air inlet grille is available for your model, follow the
installation procedures.

(1) Open holes on rear side the outdoor unit ( P x 6) using the self-tapping screw 4 .

Unit: mm

244 309 492 309 749 100 121


P
119

(2) Attach the Stay ( 2 ) to the outdoor unit by fixing the screws ( 3 x 4) to the middle holes (x 2) on the
top of the outdoor unit from step (1) and to the existing holes (x 2) on the bottom of the outdoor unit.

Outdoor Unit
3

FAN-2209 201709 2-125


AIR INLET GRILLE

(3) Hook the “A” part (edges of air inlet grille) between the heat exchanger and bottom base of unit. Mount
the air inlet grille using the screws ( 3 x 20).

Enlarged View of “A”

Heat Exchanger

Air Inlet Grille


3

Bottom Base

A
(each two places)

5. Installation Appearance
Unit: mm
Center Stay
Screws
(Accessory)

Air Inlet Grille Air Inlet Grille


[for Side [for Left Side
Installation] Installation]
1675

(Other Air Inlet (Other Air Inlet


Grille Option) Grille Option)

Air Inlet Grille


Outdoor Unit [for Rear Side
1600 Installation] 765

< Right Side > < Rear Side > < Left Side >

Available Combinations
Model
Heat RAS-20 - 24FSNS, RAS-16, 18FSNP
Applicable Outdoor Unit
Pump JTOH200 - 240VPE(U,F,R)BS1
(Representative Model)
Heat RAS-20 - 24FSXNS, RAS-16, 18FSXNP
Recovery JTOR200 - 240VPE(U,F,R)BS1

Air Inlet Grille for Rear Side PSN-TP20BC

Air Inlet Grille for Left Side PSN-TP20R

Air Inlet Grille for Right Side PSN-TP20R

NOTICE:
● This manual applies only to the combination indicated with .
For other air inlet grille options, refer to each model’s installation manual.
● Install the required air inlet grille only if all installation requirements can be met.

© 2017 Johnson Controls-Hitachi Air Conditioning Technology (Hong Kong) Ltd.

P5416991-rev.1, 2017

2-126 FAN-2209 201709


AIR INLET GRILLE

Installation Manual for Air Inlet Grille


(for Left Side Installation of Outdoor Unit)
Model: PSN-TP20L

This air inlet grille is to caution not to touch the outdoor unit heat exchanger reaching from air inlet. It is not
designed to prevent people reaching to the heat exchanger. Install it as instructed in this manual.

IMPORTANT NOTICE:
● Read and understand this manual before using this air inlet grille.
● Perform the test run after installation to check for abnormalities.
● Forward this information to the building owner and request that they maintain all the equipment manuals.
● Signal words are used to identify levels of hazard seriousness.
Definitions for identifying hazard levels are provided below with their respective signal words.

: Indicates a hazardous situation that, if not avoided,


could result in minor or moderate injury.

1. Applicable Unit
NOTICE:
The applicable outdoor unit may be different depending on the product series. Be sure to confirm with the
product catalog before installation.

Name Air Inlet Grille (for Left Side Installation)


Model PN-TP20L
Required Qty. 1
Heat RAS-8 - 12FSNS, RAS-5, 6FSNP
Applicable Outdoor Unit Pump JTOH080 - 120VPE(U,F,R)BS1
(Representative Model) Heat RAS-8 - 12FSXNS, RAS-5, 6FSXNP
Recovery JTOR080 - 120VPE(U,F,R)BS1

2. Installation Work
(1) Be sure to securely tighten the air inlet grille with the supplied screws (accessories).
If the screws are not securely tightened, it may cause vibration or abnormal sound.
If they are over-tightened, the screw threads may be stripped. When tightening the screws, make sure
to follow the tightening torque below.
● Tightening Torque: 2.0+0.5 N●m
(2) Secure enough service space with consideration for attaching/detaching the air inlet grille.
● Service Space with Air Inlet Grille: Service Space for Outdoor Unit + Min. 150mm
(3) The air inlet grille may accumulate ice or snow during cold weather.
(4) Apply touch-up coating to the screw fixing part on the outdoor unit to prevent rust formation (local
supply).

FAN-2209 201709 2-127


AIR INLET GRILLE

3. Before Installation
Check that all the following accessories are packed with the unit before installation.
Unit: mm
Qty.
No. Accessory Remarks
PSN-TP20L

Air Inlet Grille


1 (for Left Side 1
Installation) 1189

503

( ) indicate
2
M5 x 12L 7
Screw the number of
(with Washer) (1)
spare part

4. Installation Procedures
Before installation, confirm the outdoor unit model. If the air inlet grille is available for your model, follow the
installation procedures.

Remove three screws fixing the side cover to the the outdoor unit.
Hook the “A” part (edges of air inlet grille) between the heat exchanger and bottom base of unit. Mount the
air inlet grille using the screws ( 2 x 6).

< Rear Side >

Screws (Accessory, x3) 2


Outdoor Unit

Enlarged View of “A”

< Front Side >

Side Cover
Heat Exchanger
A
(two places) Air Inlet Grille
2 Screws (Accessory, x3)
Replace with the fixing
scres to the side cover.
Bottom Base

2-128 FAN-2209 201709


AIR INLET GRILLE

5. Installation Appearance
The following examples illustrate a small cabinet.
Unit: mm

Air Inlet Grille


[for Rear Side Screws
Installation] (Accessory)
(Other Air Inlet
Grille Option)
Air Inlet Grille

1675
Air Inlet Grille [for Left Side
[for Side Installation]
Installation]
(Other Air Inlet
Grille Option)

Outdoor Unit 765

< Right Side > < Rear Side > < Left Side >

Available Combinations
Model
RAS-8 - 12FSNS RAS-14 - 18FSNS RAS-20 - 24FSNS
Applicable Heat
RAS-5, 6FSNP RAS-8 - 14FSNP RAS-16, 18FSNP
Outdoor Unit Pump
JTOH080 - 120VPE(U,F,R)BS1 JTOH140 - 180VPE(U,F,R)BS1 JTOH200- 240VPE(U,F,R)BS1
(Representative
Model) RAS-8 - 12FSXNS RAS-14 - 18FSXNS RAS-20 - 24FSXNS
Heat
RAS-5, 6FSXNP RAS-8 - 14FSXNP RAS-16, 18FSXNP
Recovery
JTOR080 - 120VPE(U,F,R)BS1 JTOR140 - 180VPE(U,F,R)BS1 JTOR200 - 240VPE(U,F,R)BS1
Air Inlet Grille for
PSN-TP20BA PSN-TP20BB PSN-TP20BC
Rear Side
Air Inlet Grille for
PSN-TP20L PSN-TP20R
Left Side
Air Inlet Grille for
PSN-TP20R
Right Side

NOTICE:
● This manual applies only to the combination indicated with .
For other air inlet grille options, refer to each model’s installation manual.
● Install the required air inlet grille only if all installation requirements can be met.

© 2017 Johnson Controls-Hitachi Air Conditioning Technology (Hong Kong) Ltd.

P5416990-rev.1, 2017

FAN-2209 201709 2-129


AIR INLET GRILLE

Installation Manual for Air Inlet Grille


(for Side Installation of Outdoor Unit)
Model: PSN-TP20R

This air inlet grille is to caution not to touch the outdoor unit heat exchanger reaching from air inlet. It is not
designed to prevent people reaching to the heat exchanger. Install it as instructed in this manual.

IMPORTANT NOTICE:
● Read and understand this manual before using this air inlet grille.
● Perform the test run after installation to check for abnormalities.
● Forward this information to the building owner and request that they maintain all the equipment manuals.
● Signal words are used to identify levels of hazard seriousness.
Definitions for identifying hazard levels are provided below with their respective signal words.

: Indicates a hazardous situation that, if not avoided,


could result in minor or moderate injury.

1. Applicable Unit
NOTICE:
The applicable outdoor unit may be different depending on the product series. Be sure to confirm with the
product catalog before installation.

Name Air Inlet Grille (for Side Installation)


Model PSN-TP20R
Required Qty. 1 2
Heat RAS-8 - 12FSNS, RAS-5, 6FSNP RAS-14 - 24FSNS, RAS-8 - 18FSNP
Applicable Outdoor Unit Pump JTOH080 - 120VPE(U,F,R)BS1 JTOH140 - 240VPE(U,F,R)BS1
(Representative Model) Heat RAS-8 - 12FSXNS, RAS-5, 6FSXNP RAS-14 - 24FSXNS, RAS-8 - 18FSXNP
Recovery JTOR080 - 120VPE(U,F,R)BS1 JTOR140 - 240VPE(U,F,R)BS1

2. Installation Work
(1) Be sure to securely tighten the air inlet grille with the supplied screws (accessories).
If the screws are not securely tightened, it may cause vibration or abnormal sound.
If they are over-tightened, the screw threads may be stripped. When tightening the screws, make sure
to follow the tightening torque below.
● Tightening Torque: 2.0+0.5 N●m
(2) Secure enough service space with consideration for attaching/detaching the air inlet grille.
● Service Space with Air Inlet Grille: Service Space for Outdoor Unit + Min. 150mm
(3) The air inlet grille may accumulate ice or snow during cold weather.
(4) Apply touch-up coating to the screw fixing part on the outdoor unit to prevent rust formation (local
supply).

2-130 FAN-2209 201709


AIR INLET GRILLE

3. Before Installation
Check that all the following accessories are packed with the unit before installation.
Unit: mm
Qty.
No. Accessory Remarks
PSN-TP20L

Air Inlet Grille


1 (for Side 1189 1
Installation)

613

( ) indicate
2
M5 x 12L 7
Screw the number of
(with Washer) (1)
spare part

4. Installation Procedures
Before installation, confirm the outdoor unit model. If the air inlet grille is available for your model, follow the
installation procedures.

Remove three screws fixing the side cover to the outdoor unit.
Hook the “A” part (edges of air inlet grille) between the heat exchanger and bottom base of unit. Mount the
air inlet grille using the screws ( 2 x 6).

< Front Side >


2 Screws (Accessory, x3)
Replace with the fixing
scrwes to the side cover. < Rear Side >

1
Side Cover
Screws (Accessory, x3) 2

< Front Side >


< Rear Side > Outdoor Unit
A Side Cover
Outdoor Unit A
(two places)
1 (two places)
Enlarged View of “A”
2 Screws (Accessory, x3) Screws (Accessory, x3) 2
Replace with the fixing
scrwes to the side cover.
Heat Exchanger

Air Inlet Grille

Bottom Base

FAN-2209 201709 2-131


AIR INLET GRILLE

5. Installation Appearance
The following examples illustrate a small cabinet.
Unit: mm

Air Inlet Grille


[for Rear Side Screws
Installation] (Accessory)
(Other Air Inlet
Grille Option)
Air Inlet Grille

1675
Air Inlet Grille [for Left Side
[for Side Installation]
Installation] (Other Air Inlet
Grille Option)

Outdoor Unit 765

< Right Side > < Rear Side > < Left Side >

Available Combinations
Model
RAS-8 - 12FSNS RAS-14 - 18FSNS RAS-20 - 24FSNS
Applicable Heat
RAS-5, 6FSNP RAS-8 - 14FSNP RAS-16, 18FSNP
Outdoor Unit Pump
JTOH080 - 120VPE(U,F,R)BS1 JTOH140 - 180VPE(U,F,R)BS1 JTOH200- 240VPE(U,F,R)BS1
(Representative
Model) RAS-8 - 12FSXNS RAS-14 - 18FSXNS RAS-20 - 24FSXNS
Heat
RAS-5, 6FSXNP RAS-8 - 14FSXNP RAS-16, 18FSXNP
Recovery
JTOR080 - 120VPE(U,F,R)BS1 JTOR140 - 180VPE(U,F,R)BS1 JTOR200 - 240VPE(U,F,R)BS1
Air Inlet Grille for
PSN-TP20BA PSN-TP20BB PSN-TP20BC
Rear Side
Air Inlet Grille for
PSN-TP20L PSN-TP20R
Left Side
Air Inlet Grille for
PSN-TP20R
Right Side

NOTICE:
● This manual applies only to the combination indicated with .
For other air inlet grille options, refer to each model’s installation manual.
● Install the required air inlet grille only if all installation requirements can be met.

© 2017 Johnson Controls-Hitachi Air Conditioning Technology (Hong Kong) Ltd.

P5416989-rev.1, 2017

2-132 FAN-2209 201709


PROTECTION NET

Installation Manual for Protection Net


(for Rear Side Installation of Outdoor Unit)
Model: PN-TP20BA
PN-TP20BB

This protection net is to protect the outdoor unit heat exchanger from external damages such as being hit
by a ball. Install it as instructed in this manual.

IMPORTANT NOTICE:
● Read and understand this manual before using this protection net.
● Perform the test run after installation to check for abnormalities.
● Forward this information to the building owner and request that they maintain all the equipment manuals.
● Signal words are used to identify levels of hazard seriousness.
Definitions for identifying hazard levels are provided below with their respective signal words.

: Indicates a hazardous situation that, if not avoided,


could result in minor or moderate injury.

1. Applicable Unit
NOTICE:
The applicable outdoor unit may be different depending on the product series. Be sure to confirm with the
product catalog before installation.

Name Protection Net (for Rear Side Installation)


Model PN-TP20BA PN-TP20BB
Required Qty. 1 1
Heat RAS-8 - 12FSNS, RAS-5, 6FSNP RAS-14 - 18FSNS, RAS-8 - 14FSNP
Applicable Outdoor Unit Pump JTOH080 - 120VPE(U,F,R)BS1 JTOH140 - 180VPE(U,F,R)BS1
(Representative Model) Heat RAS-8 - 12FSXNS, RAS-5, 6FSXNP RAS-14 - 18FSXNS, RAS-8 - 14FSXNP
Recovery JTOR080 - 120VPE(U,F,R)BS1 JTOR140 - 180VPE(U,F,R)BS1

2. Installation Work
(1) Be sure to securely tighten the protection net with the supplied screws (accessories).
If the screws are not securely tightened, it may cause vibration or abnormal sound.
If they are over-tightened, the screw threads may be stripped. When tightening the screws, make sure
to follow the tightening torque below.
● Tightening Torque: 2.0+0.5 N●m
(2) Secure enough service space with consideration for attaching/detaching the protection net.
● Service Space with Protection Net: Service Space for Outdoor Unit + Min. 150mm
(3) Do not step on the protection net or the outdoor unit to prevent falls and injury.
(4) Fallen leaves or other debris may be caught by the protection net and cause airflow restrictions. Be
sure to check for accumulation and clean the protection net periodically.
(5) The protection net may accumulate ice or snow during cold weather.
(6) Apply touch-up coating to the screw fixing part on the outdoor unit to prevent rust formation (local
supply).

NOTICE:
Do not use the snow protection hood for the rear side inlet if the protection net is installed.

FAN-2209 201709 2-133


PROTECTION NET

3. Before Installation
Check that all the following accessories are packed with the unit before installation.
Unit: mm
Qty.
No. Accessory Remarks
PN-TP20BA PN-TP20BB

852 1 -
Protection Net
1 (for Rear Side a
1415
Installation)
1112 - 1
a

( ) indicate
2
M5 x 12L 11 11
Screw the number of
(with Washer) (1) (1)
spare part

3
Self-Tapping M4 x 13L
2 2 for drilling
Screw (without Washer)

4. Installation Procedures
Before installation, confirm the outdoor unit model. If the protection net is available for your model, follow
the installation procedures.

(1) Drill holes on rear side the outdoor unit ( P x 2) using the self-tapping screws ( 3 ).

Unit: mm
a 287 Outdoor Unit
a
(Representative Model)
P RAS-8 - 12FSNS, RAS-5, 6FSNP
RAS-8 - 12FSXNS, RAS-5, 6FSXNP
330
JTOH080 - 120VPE(U,F,R)BS1
119

JTOR080 - 120VPE(U,F,R)BS1
RAS-14 - 18FSNS, RAS-8 - 14FSNP
RAS-14 - 18FSXNS, RAS-8 - 14FSXNP
460
JTOH140 - 180VPE(U,F,R)BS1
JTOR140 - 180VPE(U,F,R)BS1

(2) Hook the “A” part (edges of protection net) between the heat exchanger and bottom base of unit.
Mount the protection net using the screws ( 2 x 10).

Enlarged View of “A”

2 Heat Exchanger

Protection Net

Outdoor Unit Bottom Base


A
(two places)

2-134 FAN-2209 201709


PROTECTION NET

5. Installation Appearance
Unit: mm
PN-TP20BA
Screws

Protection Net
[for Left Side
Installation]
Protection Net (Other Protection

1675
[for Side Net Option)
Installation]
(Other Protection Protection Net
Net Option) [for Rear Side
Installation]
Outdoor Unit
100 950 100 100 765

< Right Side > < Rear Side > < Left Side >

PN-TP20BB
Screws

Protection Net
[for Side
Installation]
Protection Net 1675 (Other Protection
[for Side Net Option)
Installation]
(Other Protection Protection Net
Net Option) [for Rear Side
Installation]
Outdoor Unit
100 1210 100 100 765

< Right Side > < Rear Side > < Left Side >

Available Combinations
Model
Heat RAS-8 - 12FSNS, RAS-5, 6FSNP RAS-14 - 18FSNS, RAS-8 - 14FSNP
Applicable Outdoor Unit
Pump JTOH080 - 120VPE(U,F,R)BS1 JTOH140 - 180VPE(U,F,R)BS1
(Representative Model)
Heat RAS-8 - 12FSXNS, RAS-5, 6FSXNP RAS-14 - 18FSXNS, RAS-8 - 14FSXNP
Recovery JTOR080 - 120VPE(U,F,R)BS1 JTOR140 - 180VPE(U,F,R)BS1

Protection Net for Rear Side PN-TP20BA PN-TP20BB

Protection Net for Left Side PN-TP20L PN-TP20R

Protection Net for Right Side PN-TP20R

NOTICE:
● This manual applies only to the combination indicated with .
For other protection net options, refer to each model’s installation manual.
● Install the required protection net only if all installation requirements can be met.

© 2017 Johnson Controls-Hitachi Air Conditioning Technology (Hong Kong) Ltd.

P5416992-rev.1, 2017

FAN-2209 201709 2-135


PROTECTION NET

Installation Manual for Protection Net


(for Rear Side Installation of Outdoor Unit)
Model: PN-TP20BC

This protection net is to protect the outdoor unit heat exchanger from external damages such as being hit
by a ball. Install it as instructed in this manual.

IMPORTANT NOTICE:
● Read and understand this manual before using this protection net.
● Perform the test run after installation to check for abnormalities.
● Forward this information to the building owner and request that they maintain all the equipment manuals.
● Signal words are used to identify levels of hazard seriousness.
Definitions for identifying hazard levels are provided below with their respective signal words.

: Indicates a hazardous situation that, if not avoided,


could result in minor or moderate injury.

1. Applicable Unit
NOTICE:
The applicable outdoor unit may be different depending on the product series. Be sure to confirm with the
product catalog before installation.

Name Protection Net (for Rear Side Installation)


Model PN-TP20BC
Required Qty. 1
Heat RAS-20 - 24FSNS, RAS-16, 18FSNP
Applicable Outdoor Unit Pump JTOH200 - 240VPE(U,F,R)BS1
(Representative Model) Heat RAS-20 - 24FSXNS, RAS-16, 18FSXNP
Recovery JTOR200 - 240VPE(U,F,R)BS1

2. Installation Work
(1) Be sure to securely tighten the protection net with the supplied screws (accessories).
If the screws are not securely tightened, it may cause vibration or abnormal sound.
If they are over-tightened, the screw threads may be stripped. When tightening the screws, make sure
to follow the tightening torque below.
● Tightening Torque: 2.0+0.5 N●m
(2) Secure enough service space with consideration for attaching/detaching the protection net.
● Service Space with Protection Net: Service Space for Outdoor Unit + Min. 150mm
(3) Do not step on the protection net or the outdoor unit to prevent falls and injury.
(4) Fallen leaves or other debris may be caught by the protection net and cause airflow restrictions. Be
sure to check for accumulation and clean the protection net periodically.
(5) The protection net may accumulate ice or snow during cold weather.
(6) Apply touch-up coating to the screw fixing part on the outdoor unit to prevent rust formation (local
supply).

NOTICE:
Do not use the snow protection hood for the rear side inlet if the protection net is installed.

2-136 FAN-2209 201709


PROTECTION NET

3. Before Installation
Check that all the following accessories are packed with the unit before installation.
Unit: mm
Qty.
No. Accessory Remarks
PN-TP20BC

Protection Net
1 (for Rear Side 2
1415
Installation)

702

2 Stay 1

( ) indicate
3
M5 x 12L 25
Screw the number of
(with Washer) (1)
spare part

4
Self-Tapping M4 x 13L
3 for drilling
Screw (without Washer)

4. Installation Procedures
Before installation, confirm the outdoor unit model. If the protection net is available for your model, follow
the installation procedures.

(1) Drill holes on rear side the outdoor unit ( P x 6) with Self-Tapping Screw ( 4 ) by using a charging
driver or etc..
Unit: mm

244 309 492 309 749 100 121


P
119

(2) Attach the stay ( 2 ) to the outdoor unit by fixing the screws ( 3 x 4) to the middle holes (x 2) on the top
of the outdoor unit from step (1) and to the existing holes (x 2) on the bottom of the outdoor unit.

Outdoor Unit
3

FAN-2209 201709 2-137


PROTECTION NET

(3) Hook the “A” part (edges of protection net) between the heat exchanger and bottom base of unit.
Mount the air protection net using the screws ( 3 x 20).

Enlarged View of “A”

Heat Exchanger

Protection Net

A Bottom Base
(each two places)

5. Installation Appearance
Unit: mm
Screws

Protection Net
Protection Net [for Side
[for Side Installation]
Installation]
1675

(Other Protection
(Other Protection Net Option)
Net Option)

Protection Net
[for Rear Side
Outdoor Unit Installation]
100 1600 100 100 765

< Right Side > < Rear Side > < Left Side >

Available Combinations
Model
Heat RAS-20 - 24FSNS, RAS-16, 18FSNP
Applicable Outdoor Unit
Pump JTOH200 - 240VPE(U,F,R)BS1
(Representative Model)
Heat RAS-20 - 24FSXNS, RAS-16, 18FSXNP
Recovery JTOR200 - 240VPE(U,F,R)BS1

Protection Net for Rear Side PN-TP20BC

Protection Net for Left Side PN-TP20R

Protection Net for Right Side PN-TP20R

NOTICE:
● This manual applies only to the combination indicated with .
For other protection net options, refer to each model’s installation manual.
● Install the required protection net only if all installation requirements can be met.

© 2017 Johnson Controls-Hitachi Air Conditioning Technology (Hong Kong) Ltd.

P5416993-rev.1, 2017

2-138 FAN-2209 201709


PROTECTION NET

Installation Manual for Protection Net


(for Left Side Installation of Outdoor Unit)
Model: PN-TP20L

This protection net is to protect the outdoor unit heat exchanger from external damages such as being hit
by a ball. Install it following the directions below.

IMPORTANT NOTICE:
● Read and understand this manual before using this protection net.
● Perform the test run after installation to check for abnormalities.
● Forward this information to the building owner and request that they maintain all the equipment manuals.
● Signal words are used to identify levels of hazard seriousness.
Definitions for identifying hazard levels are provided below with their respective signal words.

: Indicates a hazardous situation that, if not avoided,


could result in minor or moderate injury.

1. Applicable Unit
NOTICE:
The applicable outdoor unit may be different depending on the product series. Be sure to confirm with the
product catalog before installation.

Name Protection Net (for Left Side Installation)


Model PN-TP20L
Required Qty. 1
Heat RAS-8 - 12FSNS, RAS-5, 6FSNP
Applicable Outdoor Unit Pump JTOH080 - 120VPE(U,F,R)BS1
(Representative Model) Heat RAS-8 - 12FSXNS, RAS-5, 6FSXNP
Recovery JTOR080 - 120VPE(U,F,R)BS1

2. Installation Work
(1) Be sure to securely tighten the protection net with the supplied screws (accessories).
If the screws are not securely tightened, it may cause vibration or abnormal sound.
If they are over-tightened, the screw threads may be stripped. When tightening the screws, make sure
to follow the tightening torque below.
● Tightening Torque: 2.0+0.5 N●m
(2) Secure enough service space with consideration for attaching/detaching the protection net.
● Service Space with Protection Net: Service Space for Outdoor Unit + Min. 150mm
(3) Do not step on the protection net or the outdoor unit to prevent falls and injury.
(4) Fallen leaves or other debris may be caught by the protection net and cause airflow restrictions. Be
sure to check for accumulation and clean the protection net periodically.
(5) The protection net may accumulate ice or snow during cold weather.
(6) Apply touch-up coating to the screw fixing part on the outdoor unit to prevent rust formation (local
supply).

NOTICE:
Do not use the snow protection hood for the rear side inlet if the protection net is installed.

FAN-2209 201709 2-139


PROTECTION NET

3. Before Installation
Check that all the following accessories are packed with the unit before installation.
Unit: mm
Qty.
No. Accessory Remarks
PN-TP20L

Protection Net
1 (for Left Side 1
1183
Installation)

503

( ) indicate
2
M5 x 12L 7
Screw the number of
(with Washer) (1)
spare part

4. Installation Procedures
Before installation, confirm the outdoor unit model. If the protection net is available for your model, follow
the installation procedures.
Remove the three screws fixing the side cover to the the outdoor unit.
Insert the two screws 2 at the top of the outdoor unit left side but do not tighten. Hook the protection net (for
left side installation) 1 over the two screws. Securely tighten the other four screws 2 . Finally, tighten the
top two screws completely.

Outdoor Unit

< Rear Side >

Outdoor Unit Securing Screw


(Accessory)

Protection Net
(for Left Side Installation)

Screws (Accessory, x3) 2 < Front Side >

Side Cover
1
Scres (Accessory, x3) 2
Replace with the fixing
screws to the side cover.

2-140 FAN-2209 201709


PROTECTION NET

5. Installation Appearance
The following examples illustrate a small cabinet.

Unit: mm
Securing
Screw
(Accessory)

Protection Net Protection Net


[for Side [for Left Side
Installation] Installation]

1675
(Other Protection
Net Option) Protection Net
[for Rear Side
Installation]
(Other Protection
Outdoor Unit Net Option)
100 100 100 765

Right Side Rear Side Left Side

Available Combinations
Model
RAS-8 - 12FSNS RAS-14 - 18FSNS RAS-20 - 24FSNS
Applicable Heat
RAS-5, 6FSNP RAS-8 - 14FSNP RAS-16, 18FSNP
Outdoor Unit Pump
JTOH080 - 120VPE(U,F,R)BS1 JTOH140 - 180VPE(U,F,R)BS1 JTOH200- 240VPE(U,F,R)BS1
(Representative
Model) RAS-8 - 12FSXNS RAS-14 - 18FSXNS RAS-20 - 24FSXNS
Heat
RAS-5, 6FSXNP RAS-8 - 14FSXNP RAS-16, 18FSXNP
Recovery
JTOR080 - 120VPE(U,F,R)BS1 JTOR140 - 180VPE(U,F,R)BS1 JTOR200 - 240VPE(U,F,R)BS1
Protection Net for
PN-TP20BA PN-TP20BB PN-TP20BC
Rear Side
Protection Net for
PN-TP20L PN-TP20R
Left Side
Protection Net for
PN-TP20R
Right Side

NOTICE:
● This manual applies only to the combination indicated with .
For other protection net options, refer to each model’s installation manual.
● Install the required protection net only if all installation requirements can be met.

© 2017 Johnson Controls-Hitachi Air Conditioning Technology (Hong Kong) Ltd.

P5416995-rev.1, 2017

FAN-2209 201709 2-141


PROTECTION NET

Installation Manual for Protection Net


(for Side Installation of Outdoor Unit)
Model: PN-TP20R

This protection net is to protect the outdoor unit heat exchanger from external damages such as being hit
by a ball. Install it following the instructions below.

IMPORTANT NOTICE:
● Read and understand this manual before using this protection net.
● Perform the test run after installation to check for abnormalities.
● Forward this information to the building owner and request that they maintain all the equipment manuals.
● Signal words are used to identify levels of hazard seriousness.
Definitions for identifying hazard levels are provided below with their respective signal words.

: Indicates a hazardous situation that, if not avoided,


could result in minor or moderate injury.

1. Applicable Unit
NOTICE:
The applicable outdoor unit may be different depending on the product series. Be sure to confirm with the
product catalog before installation.

Name Protection Net (for Side Installation)


Model PN-TP20R
Required Qty. 1 2
Heat RAS-8 - 12FSNS, RAS-5, 6FSNP RAS-14 - 24FSNS, RAS-8 - 18FSNP
Applicable Outdoor Unit Pump JTOH080 - 120VPE(U,F,R)BS1 JTOH140 - 240VPE(U,F,R)BS1
(Representative Model) Heat RAS-8 - 12FSXNS, RAS-5, 6FSXNP RAS-14 - 24FSXNS, RAS-8 - 18FSXNP
Recovery JTOR080 - 120VPE(U,F,R)BS1 JTOR140 - 240VPE(U,F,R)BS1

2. Installation Work
(1) Be sure to securely tighten the protection net with the supplied screws (accessories).
If the screws are not securely tightened, it may cause vibration or abnormal sound.
If they are over-tightened, the screw threads may be stripped. When tightening the screws, make sure
to follow the tightening torque below.
● Tightening Torque: 2.0+0.5 N●m
(2) Secure enough service space with consideration for attaching/detaching the protection net.
● Service Space with Protection Net: Service Space for Outdoor Unit + Min. 150mm
(3) Do not step on the protection net or the outdoor unit to prevent falls and injury.
(4) Fallen leaves or other debris may be caught by the protection net and cause airflow restrictions. Be
sure to check for accumulation and clean the protection net periodically.
(5) The protection net may accumulate ice or snow during cold weather.

NOTICE:
Do not use the snow protection hood for the side inlet if the protection net is installed.

2-142 FAN-2209 201709


PROTECTION NET

3. Before Installation
Check that all the following accessories are packed with the unit before installation.
Unit: mm
Qty.
No. Accessory Remarks
PN-TP20R

1183
Protection Net
1 (for Side 1
Installation)

614

( ) indicate
2
M5 x 12L 9
Screw the number of
(with Washer) (2)
spare part

for drilling,
3
Self-Tapping M4 x 13L 2 ( ) indicate
Screw (without Washer) (1) the number of
spare part

FAN-2209 201709 2-143


PROTECTION NET

4. Installation Procedures
Before installation, confirm the outdoor unit model. If the protection net is available for your model, follow
the installation procedures.

(1) Open holes at the location shown below using the self-tapping screw 3 . Remove three screws fixing
the side cover to the outdoor unit.

Unit: mm

[For Right Side Installation] [For Left Side Installation]

Open a hole
( RAS-14
RAS-14 - 24FSXNS, RAS-8 - 18FSXNP and JTOR140 - 240VPE(U,F,R)BS1)
- 24FSNS, RAS-8 - 18FSNP and JTOH140 - 240VPE(U,F,R)BS1

191 191

< Front Side > < Rear Side > < Rear Side > < Front Side >

Open a hole
Remove the screws (x3) Remove the screws (x3)
fixing the side cover. fixing the side cover.
1311

1311
Side Cover

Side Cover

(2) Insert the screws 2 to the opened holes in step (1) but do not tighten. Loosen but do not remove one
screw attached at the top of the outdoor unit right side. Hook the protection net (for side installation) 1
over the top. Securely tighten the six screws 2 . Finally, tighten the top two screws completely.
NOTE:
Same procedure is applied when the protection net is used for left side installation.
<Applicable Model>
Heat Pump: RAS-14 - 24FSNS, RAS-8 - 18FSNP and JTOH140 - 240VPE(U,F,R)BS1
Heat Recovery: RAS-14 - 24FSXNS, RAS-8 - 18FSXNP and JTOR140 - 240VPE(U,F,R)BS1

[For Right Side Installation]

Attached
Screw

Outdoor Unit

2 2
1

Protection Net Securing Screw


(for Side Installation) (Accessory)

2-144 FAN-2209 201709


PROTECTION NET

5. Installation Appearance
The following examples illustrate a small cabinet.

Unit: mm
Securing
Screw
(Accessory)
Protection Net
Protection Net [for Left Side
[for Side Installation]
Installation] (Other Protection

1675
Net Option)

Protection Net
[for Rear Side
Installation]
Outdoor Unit (Other Protection
100 100 Net Option) 100 765

< Right Side > < Rear Side > < Left Side >

Available Combinations
Model
RAS-8 - 12FSNS RAS-14 - 18FSNS RAS-20 - 24FSNS
Applicable Heat
RAS-5, 6FSNP RAS-8 - 14FSNP RAS-16, 18FSNP
Outdoor Unit Pump
JTOH080 - 120VPE(U,F,R)BS1 JTOH140 - 180VPE(U,F,R)BS1 JTOH200- 240VPE(U,F,R)BS1
(Representative
Model) RAS-8 - 12FSXNS RAS-14 - 18FSXNS RAS-20 - 24FSXNS
Heat
RAS-5, 6FSXNP RAS-8 - 14FSXNP RAS-16, 18FSXNP
Recovery
JTOR080 - 120VPE(U,F,R)BS1 JTOR140 - 180VPE(U,F,R)BS1 JTOR200 - 240VPE(U,F,R)BS1
Protection Net for
PN-TP20BA PN-TP20BB PN-TP20BC
Rear Side
Protection Net for
PN-TP20L PN-TP20R
Left Side
Protection Net for
PN-TP20R
Right Side

NOTICE:
● This manual applies only to the combination indicated with .
For other protection net options, refer to each model’s installation manual.
● Install the required protection net only if all installation requirements can be met.

© 2017 Johnson Controls-Hitachi Air Conditioning Technology (Hong Kong) Ltd.

P5416994-rev.1, 2017

FAN-2209 201709 2-145


CH BOX

Installation
Manual
for
Cooling / Heating
Change-Over Box
CH-Box

Models:

CH-AP160SSX
CH-AP280SSX

JCH-AP160SSX
JCH-AP280SSX

IMPORTANT:

READ AND UNDERSTAND


THIS MANUAL CAREFULLY
BEFORE INSTALLING
THIS CH-BOX.
KEEP THIS MANUAL FOR
FUTURE REFERENCE. P5417023
FAN-2212 201711

2-146 FAN-2209 201709


CH BOX

Interchangeability between Current and New CH-Boxes


● New CH-Box is compatible for the new outdoor unit.
Current CH-Box is compatible for the new outdoor unit with limitation.
Refer to the Technical Manual for the outdoor unit for more details.
Current outdoor unit is compatible with current CH unit only.
(When the New CH-Box is connected to current VRF outdoor unit, the unit will not operate and the wired
controller will display the alarm code “C4“.)

4: Available
4
4
Current CH Unit Current VRF (Heat Recovery)
×: Not Available
×
4
4
New CH-Box New VRF (Heat Recovery)
4
4

● Current and new CH-Boxes can not be used in the same system together.
● Production of current CH unit shall be discontinued. However, it will be supplied for servicing and
maintenance until further notice. Contact us if there are order request for the current CH unit.

P5417023-rev.1 i

FAN-2209 201709 2-147


CH BOX

IMPORTANT NOTICE

● The applicable outdoor unit may be different depending on the product series.
Improper combination causes the unit to malfunction and an alarm will be triggered. Be sure to confirm
with the product catalogue before installation.
● The manufacturer of the product pursues a policy of continuous improvement in the design and
performance of products to meet regulatory requirements and industry standards. Therefore, the
manufacturer reserves the right to revise specifications without notice.
● The manufacturer of the product cannot anticipate every possible circumstance that might involve a
potential hazard.
● This heat pump air conditioner is designed for standard air conditioning applications only. Do not use this
heat pump air conditioner for other purposes, such as drying clothes, refrigerating foods, or for any other
cooling or heating process.
● Do not install the unit outdoors. Do not install the unit in the following places. It may cause a fire,
deformation, corrosion or failure.
* Places where there are high levels of oil mist (including machinery oil).
* Places where there are high alkalinity levels (i.e., chlorine or bromine such as over hot tubs, etc.).
* Places where flammable gases or liquids may be used or generated.
* Places with a high concentration of salts, salty mists or sprays (such as over salt-water aquariums).
* Places with an atmosphere of high nuisance dust. Places with organic solvent atmospheres, such as
painting and cleaning locations.
● Do not install a unit in the place where condensate water can leak onto the unit or electrical device failures
may occur.
● Pay attention to the following points when the unit is installed in a hospital or other facility where
electromagnetic waves generate from medical equipment.
* Do not install the unit in places where electromagnetic waves radiate to the electrical box, wired controller
cable or wired controller.
* Install the unit at least 3m (10 ft) away from electromagnetic waves or interferences such as a radio.
● The installer and system specialist shall secure against leakage according to local regulations or
standards. This system has both high and low pressure refrigerant and, as such, comprises a pressurized
system. Never loosen threaded joints while the system is under pressure and never open pressurized
system parts.
● No part of this manual may be reproduced without written permission.
● It is assumed that this heat pump air conditioner will be operated and serviced by English speaking people.
If this is not the case, the distributor or dealer can provide or add safety, caution and operating signs in the
native language.
● If you have any questions, contact your distributor.
● This manual describes the features of this heat pump air conditioner as well as for other models.
This manual should be considered as a permanent part of the air conditioning equipment and should remain
with the air conditioning equipment.

ii P5417023-rev.1

2-148 FAN-2209 201709


CH BOX

CHECKING PRODUCT RECEIVED

● Upon receiving this product, inspect it for any shipping damage.


Inspect all electrical connections. Connections must be clean and tight at the terminals.
Claims for damage either apparent or concealed, should be filed immediately with the shipping company.
NOTE: Rough handling may dislocate internal components.
● Check the model number, electrical characteristics (power supply, voltage and frequency) and accessories
to determine if they are correct with the ordering and shipping information, to ensure the correct unit has
been shipped.
To minimize the possibility of damage after inspection, the units should be installed and reassembled as
soon as possible.

The standard installation and general use of this unit is explained in this manual.
Although common processes and procedures for installing units are presented in this manual, its use for
installation of units otherwise indicated in this manual is not recommended. Please contact your local agent,
as the occasion arises.
Our liability shall not cover defects arising from the alteration performed by a customer without our consent in
a written form.

SAFETY SUMMARY

Signal Words
● Signal words are used to identify levels of hazard seriousness.
Definitions for identifying hazard levels are provided below with their respective signal words.

DANGER : DANGER indicates a hazardous situation which, if not avoided,


will result in death or serious injury.

WARNING : WARNING indicates a hazardous situation which, if not avoided,


could result in death or serious injury.

CAUTION : CAUTION used with the safety alert symbol, indicates a hazardous situation which,
if not avoided, could result in minor or moderate injury.

NOTICE : NOTICE is used to address practices not related to personal injury.

NOTE : NOTE is useful information for operation or maintenance.

P5417023-rev.1 iii

FAN-2209 201709 2-149


CH BOX

SAFETY SUMMARY

DANGER
● Do not perform installation work, refrigerant piping work, condensate pump, or condensate piping and
electrical wiring connection without referring to the installation manual. If the instructions are not followed,
it may result in a water leakage, electric shock or a fire.
● Use the specified non-flammable refrigerant (R410A) for the outdoor unit in the refrigerant cycle.
Charge only R410A into the unit. Do not charge other materials into the unit such as hydrocarbon
refrigerants (propane), oxygen, flammable gases (acetylene) or poisonous gases when installing,
maintaining and moving the unit. These flammables are extremely dangerous and may cause an
explosion, a fire, or injury. As originally manufactured, this unit contains refrigerant installed by the
manufacturer of the product. The manufacturer of the product uses only refrigerants that have been
approved for use in the unit’s intended country or market. Distributors similarly are only authorized
to provide refrigerants that have been approved for use in the countries or markets they serve. The
refrigerant used in this unit is identified on the unit’s faceplate and/or in the associated manuals. Any
additions of refrigerant into this unit must comply with the country’s requirements with regard to refrigerant
use and should be obtained from distributors. Use of unapproved refrigerant substitutes will void the
warranties and can cause injury or death.
● Do not pour water into the indoor or outdoor unit. These units are equipped with electrical parts.
Exposure to water may cause a serious electrical shock.
● Do not open the service cover or access panel for the indoor or outdoor units without turning OFF the main
power supply.
● Do not touch or adjust safety devices inside the indoor unit or outdoor units. If these devices are touched
or readjusted, it may cause a serious accident.
● Carefully check for escaping refrigerant gas. If there is significant leakage, it can cause difficulty in
breathing. Turn OFF the main switch, and contact your service contractor if refrigerant leakage occurs.
● Make sure that the refrigerant leakage test is performed.
Refrigerant (fluorocarbon) for this unit is incombustible, non-toxic and odorless.
However if the refrigerant is leaked and comes in contact with fire, toxic gas will generate.
Because fluorocarbon is heavier than air, the floor surface will be filled with it, which could cause
suffocation.
● The installer and system specialist shall secure against refrigerant leakage according to local regulations
or standards.
● Use a Earth Leakage Breaker (ELB).
In the event of fault, there is danger of an electric shock or a fire if it is not used.

iv P5417023-rev.1

2-150 FAN-2209 201709


CH BOX

SAFETY SUMMARY

WARNING
● Do not use any sprays such as insecticide, lacquer, hair spray or other flammable gases within
approximately 1.3m (4 ft) from the system.
● If the circuit breaker or fuse is often activated, stop the system and contact your service contractor.
● Check that the ground wiring is securely connected. If the unit is not correctly grounded, it may cause
electric shock. Do not connect the ground wiring to gas piping, condensate piping, lighting conductor or
ground wiring for telephones.
● Before performing any brazing work, check to ensure that there is no flammable material around.
When using refrigerant, be sure to wear leather gloves to prevent injury from cold.
● Insulate electrical wiring, condensate piping, and electrical components from threats posed by burrowing
animals and temperature extremes. Failure to do so can, over time, deteriorate system performance.
● Secure the cables. External forces on the terminals could lead to a fire.
● Tighten the flare nut with a torque wrench in the specified manner. Do not apply excessive force to the
flare nut when tightening. If you do, the flare nut can crack and refrigerant leakage may occur.
● When maintaining, relocating or disposing of the unit, dismantle the refrigerant piping after the compressor
stops.
● Highly dangerous electrical voltages are used in this system. Carefully refer to the wiring diagram and
these instructions when wiring. Improper connections and inadequate grounding can cause serious injury
or death.
● Perform all electrical work in strict accordance with this installation and maintenance manual and all
relevant regulatory standards.
● Use specified cables between units.
● Be sure to install circuit breakers (ground fault interrupter, isolating switch, molded case circuit breaker
and so on), with the specified capacity. Ensure that the wiring terminals are tightened securely to
recommended torque specifications. If a circuit breaker or fuse is frequently activated, shut down the
system and contact your service contractor.
● Clamp electrical wires securely with a cable clamp after all wiring is connected to the terminal block.
In addition, run wires securely through the wiring access channel.
● When installing the power lines, do not apply tension to the cables. Secure the suspended cables at
regular intervals, but not too tightly.
● After stopping operation, be sure to wait at least five minutes before turning off the main power switch.
Otherwise, water leakage or electrical breakdown may result. Disconnect the power supply completely
before attempting any maintenance for electrical parts. Check to ensure that no residual voltage is present
after disconnecting the power supply.
● Insulate the refrigerant pipe connection to prevent condensation.
● Be sure to attach the cover so that it fits securely on the electrical box without any gaps. Secure the cover
with screws.

P5417023-rev.1 v

FAN-2209 201709 2-151


CH BOX

CAUTION
● Do not step on the unit.
● Do not put any foreign material on the unit or inside the unit.
● Provide a strong and correct foundation so that:
● The outdoor unit is not on an incline.
● Abnormal sound does not occur.
● The outdoor unit will not fall down due to a strong wind or earthquake.

NOTICE
● Be careful that moisture, dust, or variant refrigerant compounds not enter the refrigerant system during
installation work. Foreign matter could damage internal components or cause blockages.
● Do not install the indoor unit, outdoor unit, wired controller and cable within approximately 3m (10 ft) of
strong electromagnetic wave radiators such as medical equipment.
● After a long shutdown, apply power to the outdoor unit(s) at least 12 hours prior to operation of the system
for preheating of the compressor oil.

NOTE
● It is recommended that the room is ventilated every three to four hours.
● The heating capacity of the heat pump unit is decreased according to the outdoor air temperature.
Therefore, it is recommended that auxiliary heating equipment be used in the field when the unit is
installed in a low temperature region.

vi P5417023-rev.1

2-152 FAN-2209 201709


CH BOX

TABLE OF CONTENTS

1. Safety Summary .............................................................................................................................................1

2. Structure .........................................................................................................................................................1
2.1 Dimensions.............................................................................................................................................1
2.2 Refrigeration Cycle .................................................................................................................................2
2.3 Necessary Tools and Instrument List for Installation ..............................................................................3

3. Transportation and Handling ...........................................................................................................................3


3.1 Transportation ........................................................................................................................................3
3.2 Handling of CH-Box................................................................................................................................3
3.3 Combination of CH-Box and Indoor Unit ................................................................................................3

4. CH-Box Installation .........................................................................................................................................4


4.1 Factory-Supplied Accessories ................................................................................................................4
4.2 Initial Check ............................................................................................................................................5
4.3 Suspension Bolts....................................................................................................................................6
4.4 Installation ..............................................................................................................................................7
4.4.1 Changing the Location of the Electrical Box .................................................................................7
4.4.2 Marking of the Positions of the Suspension Bolts and Wiring Connections .................................8
4.4.3 Mounting and Hanging the CH-Box ..............................................................................................8

5. Refrigerant Piping Work ..................................................................................................................................9


5.1 Refrigerant Piping...................................................................................................................................9
5.2 Refrigerant Piping Work ....................................................................................................................... 11

6. Electrical Wiring ............................................................................................................................................15


6.1 General Check .....................................................................................................................................15
6.2 Electrical Wiring Connection ................................................................................................................16
6.3 Electrical Wiring....................................................................................................................................17
6.4 Setting of DIP Switches ........................................................................................................................18

7. Test Run ........................................................................................................................................................19

8. Safety and Control Device Setting ................................................................................................................20

P5417023-rev.1 vii

FAN-2209 201709 2-153


CH BOX

1. Safety Summary

● Do not perform installation work, refrigerant Do not install the CH-Box and cable within
piping work or electrical wiring connection approximately 3m (10 ft) from strong
without referring to our installation manual. electromagnetic wave radiators such as
● Check that the ground wire is securely medical equipment.
connected.
● Connect a fuse of specified capacity.

2. Structure
2.1 Dimensions
23(7/8) 330(13) Suspension Bracket
CH-AP160SSX (For Suspension Bolt) 2×(11(7/16)×34(1-5/16)) Unit: mm(inch)
JCH-AP160SSX Slotted Hole

(1-9/16)
40
Ground Terminal (M5)
Refrigerant Gas
376(14-13/16) (in Electrical Box) Pipe Connection
Electrical Box (ϕ15.88(5/8)
38(1-1/2) 301(11-7/8) 38(1-1/2)
Refrigerant Gas (Available Flare Nut)
(Low Pressure) for both sides)
214(8-7/16) Pipe Connection
(ϕ19.05(3/4) Flare Nut)

191(7-1/2)
89(3-1/2)
180(7-1/16)

Refrigerant Gas
(1-9/16)

(high/Low Pressure)
Pipe Connection
39

(ϕ15.88(5/8) Flare Nut)


82(3-1/4) 301(11-7/8) 89(3-1/2)
25(1)
111(4-3/8)
40 54
20(13/16)

(1-9/16) (2-1/8) Indoor Unit Connecting Side


151 63(2-1/2) 40(1-9/16) 221(8-11/16)
Power Supply
(5-15/16)
38(1-1/2) Wiring Connection
(ϕ20(13/16))
Outdoor Unit Connecting Side Control Wiring
Connection
(ϕ20(13/16))
Specifications
CH-AP160SSX
Model
JCH-AP160SSX
1/N~, 230V, 50Hz
1/N~, 220-240V, 50Hz
1/N~, 220V, 60Hz
Power Supply
1~, 208-230V, 60Hz*
1~, 220V, 60Hz*
*For Mexico model only.
Power Consumption 5W
Refrigerant R410A
Net Weight 6kg
Number of Indoor Unit 6.0HP or less
Capacity (Max. 16kW)
Number of Connectable
1 to 7
Indoor Unit

Figure 2.1 Dimensions of Change-Over Box (1)

P5417023-rev.1 1

2-154 FAN-2209 201709


CH BOX

CH-AP280SSX
JCH-AP280SSX 23(7/8) 330(13)
(For Suspension Bolt)
Unit: mm(inch)

(1-9/16)
40
Suspension Bracket
2×(11(7/16)×34(1-5/16))
Slotted Hole
Ground Terminal (M5) Refrigerant Gas
376(14-13/16) (in Electrical Box) Pipe Connection
Refrigerant Gas Electrical Box (ϕ19.05(3/4)
(Low Pressure) 38(1-1/2) 301(11-7/8) 38(1-1/2)
Pipe Connection (Available Flare Nut)
8-7/16(214)
for both sides)
(ϕ19.05(3/4) Flare Nut)
Refrigerant Gas
(1-9/16)

89(3-1/2)

180(7-1/16)

191(7-1/2)
(high/Low Pressure)
Pipe Connection
39

(ϕ15.88(5/8) Flare Nut)

82(3-1/4) 301(11-7/8) 96(3-3/4)

25(1)
40 54 111(4-3/8)
20(13/16)

(1-9/16) (2-1/8)
151 63(2-1/2)
Indoor Unit Connecting Side
(5-15/16) 40(1-9/16) 221(8-11/16)
Power Supply
38(1-1/2) Wiring Connection
Outdoor Unit Connecting Side (ϕ20(13/16))
Control Wiring
Connection
(ϕ20(13/16))
Specifications
CH-AP280SSX
Model
JCH-AP280SSX
1/N~, 230V, 50Hz
1/N~, 220-240V, 50Hz
1/N~, 220V, 60Hz
Power Supply
1~, 208-230V, 60Hz*
1~ ,220V, 60Hz*
*For Mexico model only.
Power Consumption 5W
Refrigerant R410A
Net Weight 6kg
Number of Indoor Unit 6.1 to 10.0HP
Total Capacity (Max. 28kW)
Number of Connectable
1 to 8
Indoor Unit

Figure 2.2 Dimensions of Change-Over Box (2)

2.2 Refrigeration Cycle

Indoor Unit Side Outdoor Unit Side


Electronic Expansion
Valve [MVD1] Strainer
High/Low Pressure
S
Gas Pipe Connection

Electronic Expansion
Strainer Valve [MVS1] Strainer
Low Pressure
Gas Pipe Connection S S Gas Pipe Connection

: Refrigerant Pipe [Field Installation]


: Flare Nut Connection
: Brazing Connection
: CH-Box

Figure 2.3 Refrigeration Cycle Diagram

2 P5417023-rev.1

FAN-2209 201709 2-155


CH BOX

2.3 Necessary Tools and Instrument List for Installation

No. Tool No. Tool


1 Handsaw 11 Wrench
2 Phillips Screwdriver 12 Charging Cylinder
3 Vacuum Pump 13 Manifold Gauge
4 Refrigerant Gas Hose 14 Wire Cutter
5 Megohmmeter 15 Gas Leak Detector
6 Copper Pipe Bender 16 Level
7 Manual Water Pump 17 Crimper for Solderless Terminals
8 Pipe Cutter 18 Hoist (for Indoor Unit)
9 Brazing Kit 19 Ammeter
10 Hex Wrench 20 Voltage Meter
NOTE:
Use tools and measuring instruments (vacuum pump, refrigerant hose, charging cylinder, and manifold
gauge) exclusively for the refrigerant R410A.

3. Transportation and Handling

3.1 Transportation 3.2 Handling of CH-Box


Transport the product as close to the installation
location as practicable before unpacking.
Do not put any foreign material into the indoor
unit and check to ensure that none exists in
Do not put any material on the product. the CH-Box before the installation and test run.
Otherwise, a fire or failure, or something similar
may occur.

Be careful not to damage insulation materials


of unit’s surface when lifting.

3.3 Combination of CH-Box and Indoor Unit


Combination is as follows.

Table 3.1 Combination of Indoor Unit


CH-AP160SSX CH-AP280SSX
Model
JCH-AP160SSX JCH-AP280SSX
Number of Branch (for Indoor Unit) 1 1
Maximum Total Capacity of All Connected 6.0HP 10.0HP or less
Single Unit per Branch
Indoor Units (Max. 16.0kW) (Max. 28.0kW)
Maximum Number of Connected Indoor
7 8
Multiple Units per Branch Units per Branch
(*1) Maximum Total Capacity of All Connected 6.0HP 10.0HP or less
Indoor Units (Max. 16.0kW) (Max. 28.0kW)
( 1)
* When multiple indoor units are connected to the same CH-Box, they are controlled with the same
operation mode.
NOTE:
Exceeding the total capacity may cause insufficient performance and abnormal sound. Be sure to connect
the CH-Box within the allowable total capacity.

P5417023-rev.1 3

2-156 FAN-2209 201709


CH BOX

4. CH-Box Installation

4.1 Factory-Supplied Accessories


Check to ensure that the following accessories are
● Do not install the CH-Box in a flammable packed with the CH-Box.
environment to avoid fire or an explosion.

NOTE
If any of these accessories are not packed with the
unit, please contact your distributor.
● Check to ensure that the ceiling slab is strong
enough.
● Do not install the CH-Box outdoors.
If installed outdoors, an electric hazard or
electric leakage may occur.
● Installation WARNING: Ensure that all safety
features, disconnects and interlocks are
in place and functioning properly prior to
putting the equipment into operation. Never
by-pass or jump-out any safety device or
switch.

Table 4.1 Factory-Supplied Accessories


Unit: mm (inch)
CH-AP160SSX CH-AP280SSX
No. Accessory Q’ty Q’ty
JCH-AP160SSX JCH-AP280SSX

(1) Reducer ID f15.88 ID f19.05 1 - -


(5/8) (3/4)

Flaring Flaring
(2) ID f12.7 f15.88 2 ID f22.2 f19.05 2
Flare Nut
(1/2) Flare Nut (5/8) (7/8) (3/4)

Accessory Pipe Flaring Flaring


(3) ID f19.05 f19.05 1 ID f19.05 f19.05 2
(for Flare Nut)
Flare Nut
(3/4) (3/4) (3/4) (3/4)

Flaring
(4) - - ID f19.05 f15.88 1
Flare Nut
(3/4) (5/8)

ID f16
(5) 2 1
(5/8)

ID f20
(6) 1 - -
(13/16)

Insulation ID f22
(7) - - 2
Material (7/8)

ID f38
(8) 2 1
(1-1/2)

ID f43
(9) 1 2
(1-11/16)

(10) Clamp 6 6

4 P5417023-rev.1

FAN-2209 201709 2-157


CH BOX

4.2 Initial Check


● Install the CH-Box with a proper clearance ● Check to ensure that the ceiling is sufficiently
around it for maintenance working space, as strong to sustain the CH-Box. If the ceiling is
shown in Figure 4.1 below. weak, abnormal sound and vibration may occur.
● When the electronic expansion valve in the

(3-15/16)
Unit: mm (inch) CH-Box is activated, a change in the typical
refrigerant flow sounds may be heard or

100
perceived from the CH-Box. Take the following
action to minimize the sound.
Electrical Box
(A) Install the CH-Box inside the ceiling. As for
the ceiling material, select a material like a
plasterboard at least 9mm (1 inch), which
minimizes operation sound.
(B) Do not install the CH-Box in a place near
bedrooms or hospital rooms.
Service Access Door
● When the operation is changed to cooling/
heating mode, a change in the typical refrigerant
( 450 (17-11/16))
flow sounds may be heard or perceived from the
CH-Box.
2-Suspension Bolt Therefore, install the CH-Box in the ceiling of
M10 or W3/8 Upper Side the corridor so that the refrigerant flowing sound
(Field-Supplied) Min. 70 (2-3/4) may not be heard in the room.
● Do not install the CH-Box in a hot or humid
place, such as a kitchen, to prevent
condensation on the outer surface of the
CH-Box.
When installing the CH-Box in such places,
Min. A Min. A
apply additional insulation.
● Pay attention to the following points when the
Min. 2-3/4(70) CH-Box is installed in a hospital or other facility
Bottom Side where there are electronic waves from medical
equipment.
Size (A) Do not install the CH-Box where the
A
Model electromagnetic wave is directly radiated to
CH-AP160SSX
300 (11-13/16)
the electrical box or communication cable.
JCH-AP160SSX
(B) Install the CH-Box and components as far
CH-AP280SSX
JCH-AP280SSX
400 (15-3/4) as practicable or at least 3m (10 ft) from the
electromagnetic wave radiator.
Figure 4.1 Service Space (C) Install a noise filter when the power supply
emits harmful noises.
● Ensure the installation place is convenient
for the refrigerant piping or electrical wiring
connection.
● Do not drill, or drive screws into the cabinet.
Use only mounting points provided.

P5417023-rev.1 5

2-158 FAN-2209 201709


CH BOX

4.3 Suspension Bolts


Step 1 Unit: mm(inch)
(1) Select a final location and installation 23(7/8) 330(13)

40(1-9/16)
direction of the CH-Box. (For Suspension Bolt)
Pay careful attention to the space for the Suspension Bracket
piping, wiring and maintenance. 11(2-7/16) x 34(1-5/16)
Slotted Hole
(2) Mount suspension bolts.
(3) Mount the suspension bolts in the slotted
hole on the electrical box side as shown in
Figure 4.2. Electrical Box
(4) Contact a qualified contractor or carpenter
for the ceiling treatment.
Figure 4.2 Position of Suspension Bolts

Step 2
Mount suspension bolts, as shown in Figure 4.3.

 For Steel Beam  For Wooden Beam


Wooden Bar
(60 to 90mm
Antiskid Clamp Suspension Bolt (2-3/8 to 3-9/16 inch) Square)
C-shaped (Bend it) Nut Square
Clamp Wooden Washer
Beam
Nut
Suspension I Beam Nut
Square
Bolt Support Angle Washer
Suspension Bolt Suspension Bolt
Suspension Bolt (M10 or W3/8) (M10 or W3/8)
(M10 or W3/8)

 For Concrete Slab  For Reinforcing Steel


(1) Hole-In Anchor
150 to 160mm
(5-7/8 to 6-5/16 inch)
Part B Part A

Insert
100 to 150 kg
(220 to 331 lbs.)

Steal Concrete

Unit Body Use a hole saw Break a head portion Suspension Bolt
to make a hole. of anchor by using (M10 or W3/8)
a hammer.

Inserting Fixing Fixing Bolt

(2) Resin Capsule Use a suspension bolt with 30 to 45o sloping edge.
Use the resin capsule within the warranty period.
Resin capsules deteriorate over time and should be used within
six mounths of the manufacturing date.

Stiffening Glass
Agent
Stone
Epoxy Resin

Resin Capsule Use a hole saw Inserting Ambient Temp. Time


to make a hole. (with impulse rotation) 20oC (68oF) Min. 30min.
After inserting, do not rotate or put any force until resin is hardened. 15oC (59oF) Min. 1hr.
Required time is as shown in the table at right. 10oC (50oF) Min. 2hr.
5oC (41oF) Min. 4hr.
0oC (32oF) Min. 8hr.

NOTE:
 Use a suspension bolt (W3/8, Metric screw thread: M10).
 Prepare washer and nut.

Figure 4.3 Mounting of Suspension Bolts

6 P5417023-rev.1

FAN-2209 201709 2-159


CH BOX

4.4 Installation
4.4.1 Changing the Location of the Electrical Box
Depending on the installation space, changing the location of the electrical box is available.
When changing the location of the electrical box, follow the procedures below:
(1) Remove the service cover for the electrical box.
(2) Remove the service cover for the electronic expansion valve.
(3) Remove the electrical box.
(4) Remove the wiring from the wire clip and edge saddle, and move the electrical box.
After moving the electrical box, put the wiring into the edge saddle and bound with the wire clip.
(Refer to “Enlarged View of A” below.)
(5) Mount the electrical box.
(6) Rotate the service cover for the electronic expansion valve 180 degrees and mount it.
(7) Mount the service cover for the electrical box.

Service Cover for


Electronic Expansion Valve

(2) (6)

(6)
(7)
Electrical Box
(2) (6) (5)
(7)

(5)
(1) (3) A

Service Cover for (1)


Electrical Box
(3)
(4)

Enlarged View of A
Edge Saddle Wire Clip *

Wire Clip
Edge Saddle

Electrical Box

MVS1 MVS1

MVD1 MVD1

Electrical Box
Edge Saddle
Edge Saddle
(Before Change) (After Change)

* Make sure that the wiring is bound with the wire clips
in order to prevent the electrical box from entering
water.

P5417023-rev.1 7

2-160 FAN-2209 201709


CH BOX

4.4.2 Marking of the Positions of the Suspension (2) Hanging the CH-Box
Bolts and Wiring Connections (a) Hang the CH-Box by putting hands on the
(1) Mark the positions of the suspension bolts, bottom of the cabinet.
refrigerant piping connections and wiring (b) Insert the suspension bolt into the groove
connection. part of the suspension bracket as shown
(2) Installation dimensions are shown in in Figure 4.5. Ensure that the washers
Figure 2.1. are correctly affixed to the suspension
bracket.
(c) After the hanging work, the piping and
4.4.3 Mounting and Hanging the CH-Box
wiring connection work is required inside
(1) Put nuts on each of the two suspension bolts the ceiling in the gap between the roof
before hanging the CH-Box, as shown in and ceiling so it is not visible. Therefore,
Figure 4.4. determine the drawing direction of the
T Mounting washers are required in order pipe after selecting the installation location
to affix the suspension bracket to the of the CH-Box. Before doing the hanging
suspension bolt. work, carry out the piping and wiring work
up to the connecting positions.
Field-Supplied Parts (d) Keep the CH-Box level to the ceiling
* Suspension Bolt: 2-M10 or W3/8 surface. If the CH-Box is not level, a
* Nut: 6-M10 or W3/8 malfunction may occur.
* Washer: 4-M10 or W3/8 (e) Tighten the nuts of the suspension
bolt with the suspension bracket after
adjustment is completed.
Adhesive must be applied to the nuts in
Suspension Bolt (M10 or W3/8)
order to prevent them from loosening.
(Field-Supplied)

Nut (Field-Supplied) 30 to 50mm


(1-3/16 to Upper Side Suspension Bolt
Washer (Field-Supplied) 1-15/16 inch)

Suspension Bracket
(Equipped with CH-Box)

Washer (Field-Supplied)
Double-Nut (Field-Supplied)
CH-Box

Suspension Bracket

Figure 4.4 Suspension

Bottom Side

Figure 4.5 Hanging Method

8 P5417023-rev.1

FAN-2209 201709 2-161


CH BOX

5. Refrigerant Piping Work


● Flaring Dimension
Perform the flaring work as shown below.
Use the specified non-flammable refrigerant inch (mm)
90o + 2o
(R410A) for the outdoor unit in the refrigerant +0
Diameter A
cycle. Do not charge material other than 45 o
+ 2o
(ɸd)
-0.4(-0.02)
R410A into the unit such as hydrocarbon fA R410A
refrigerants (propane or something similar), 6.35 (1/4) 9.1 (0.36)
oxygen, flammable gases (acetylene or etc.) or 9.52 (3/8) 13.2 (0.52)
1/64 ~ 1/32R
poisonous gases when installing, maintaining 12.7 (1/2) 16.6 (0.65)
and moving. These flammables are extremely 15.88 (5/8) 19.7 (0.78)
dangerous and may cause an explosion, a fire, fd
19.05 (3/4) (T)
and injury.
(T) It is impossible to perform the flaring
work with 1/2H material. In this case,
5.1 Refrigerant Piping use an accessory pipe (with a flare).
(1) Prepare locally-supplied copper pipes.
(2) Select clean copper tubes making sure there
is no dust or moisture inside the tubes.
Before connecting pipes, blow the inside of
the tubes with nitrogen or dry air, to remove ● Cautions for Refrigerant Pipe Work (Example)
any dust or foreign materials. When installing pipe through Do not place the pipe
(3) Select the piping size as shown in the tables the wall, secure a cap at the
end of the pipe.
directly on the ground.
below. Furthermore, check for the flare Correct Incorrect Correct Incorrect
nut and flaring dimension according to the
following figure and table.
Hole Hole

● Joint Selection Attach a cap


Attach a cap
When using 1/2H material and the flaring work or vinyl tape.
or vinyl tape.

is not available. In this instance, use a joint


selected from the chart below. Correct Incorrect

Minimum Thickness of Joint mm(inch) Rain water can


enter.
Diameter R410A
6.35 (1/4) 0.5 (0.020)
9.52 (3/8) 0.6 (0.024) Attach a cap
or vinyl bag with
12.7 (1/2) 0.7 (0.028) rubber band.
15.88 (5/8) 0.8 (0.031)
19.05 (3/4) 0.8 (0.031)
22.2 (7/8) 0.9 (0.035)
25.4 (1) 0.95 (0.037)
28.58 (1-1/8) 1.0 (0.039)
31.75 (1-1/4) 1.1 (0.043)
38.1 (1-1/2) 1.35 (0.053)
41.28 (1-5/8) 1.45 (0.057)

Flare Nut Dimension B mm(inch)


Flare Nut
Diameter R410A
6.35 (1/4) 17 (11/16)
9.52 (3/8) 22 (7/8)
12.7 (1/2) 26 (1) B

15.88 (5/8) 29 (1-1/8)


19.05 (3/4) 36 (1-7/16)

NOTE:
Do not use a joint other than those specified in
the table above.

P5417023-rev.1 9

2-162 FAN-2209 201709


CH BOX

● Cautions for Piping Connection Work


(a) Connect the indoor/outdoor connecting
pipes. Secure the pipes and do not touch ● Do not apply excessive force to the flare
other objects, such as ceilings for example. nut when tightening. Excessive force can
(Otherwise, abnormal sound may be heard result in the flare nut cracking and refrigerant
due to the vibration of the piping.) leakage may occur. Use the specified
(b) Apply refrigerant oil slightly on the sheet tightening torque.
surface of the pipe and flare nut before the ● For more details of the refrigerant piping
flaring work. Then tighten the flare nut with work, vacuum pumping and refrigerant
the specified tightening torque using two charge, refer to the Technical Manual for the
wrenches. Always use a back-up wrench to Outdoor Unit.
prevent twisting of the copper piping within
the unit assembly. Perform the flaring work
on the liquid piping side before the gas
piping side. Check the gas leakage after the
flaring work.
NOTE:
Refrigerant oil is field-supplied.
[Ethereal Oil FVC50K, FVC68D (Idemitsu
Kousan Co. Ltd.)]
(c) When temperature and humidity inside the
ceiling exceed 27oC(80oF) /RH, relative
humidity, 80%, apply additional insulation
approximately 20mm (13/16 inch) thickness
to the accessory insulation. It prevents
condensation on the surface of the insulation
(refrigerant pipe only) and possible damage
to electronic components.
(d) Perform the air-tight leakage test 4.15MPa
(601 psi) for the test pressure. Refer to the
Technical Manual for the Outdoor Unit for
more details.
(e) Perform cold insulation work by insulating
and taping the flare connection and reducer
connection. Also insulate all the refrigerant
pipes.

Apply Refrigerant Oil.

Two wrenches required to prevent


damaging the copper piping.

Required Tightening Torque


Pipe Size Tightening Torque
6.35mm (ɸ1/4 inch) 14 to 18 N●m (10.3 to 13.3 ft.lbs)
9.52mm (ɸ3/8 inch) 34 to 42 N●m (25.1 to 31.0 ft.lbs)
12.7mm (ɸ1/2 inch) 49 to 61 N●m (36.1 to 45.0 ft.lbs)
15.88mm (ɸ5/8 inch) 68 to 82 N●m (50.2 to 60.5 ft.lbs)
19.05mm (ɸ3/4 inch) 100 to 120 N●m (73.8 to 88.5 ft.lbs)

10 P5417023-rev.1

FAN-2209 201709 2-163


CH BOX

5.2 Refrigerant Piping Work


Provide the refrigerant pipe in the field.
Make sure that the refrigerant pipe is connected to the same refrigerant cycle unit.
(1) Position of Piping Connection
Service Cover for
Unit: mm(inch)
Electronic Expansion Valve 376(14-13/16)
Electrical Box
214 Gas Pipe Connection
(8-7/16) 38 301(11-7/8) 38 (Available for
Both Sides) (φA Flare Nut)
Low Pressure (1-1/2) (1-1/2)
Gas Pipe Connection
(1-9/16)

(φ19.05(3/4) Flare Nut)

191(7-1/2)
89

(7-1/16)
180
(3-1/2)
39

Service Cover for


Electrical Box
20
(1-13/16)

High/Low Pressure 301(11-7/8) B

25(1)
82
54 Gas Pipe Connection (3-1/4) 111
(2-1/8) (φ15.88(5/8) Flare Nut) (4-3/8)
40
(1-9/16) 151 63(2-1/2) mm (inch) Indoor Unit Connecting Side
(5-15/16) Dimension
A B
Outdoor Unit Connecting Side Model
CH-AP160SSX
15.88(5/8) 89(3-1/2)
JCH-AP160SSX
CH-AP280SSX
19.05(3/4) 96(3-3/4)
JCH-AP280SSX

(2) Piping Work for CH-Box


Refer to Technical Catalogue and Installation Manual of the outdoor unit for the piping diameter and
the installation condition.
(3) Selecting Piping Size
(a) Select the size for the high/low pressure gas pipe, low pressure gas pipe and gas pipe according to
the table 5.1. The size depends on the indoor unit total capacity connected downstream of the
CH-Box.
(b) In case that the piping size from Table 5.1 and the piping connection size for CH-Box from Table 5.2
are different, use an accessory pipe according to the item 5.2(3).
(c) As for the multi-kit branch or header branch, refer to Technical Catalog for Outdoor Unit.

Table 5.1 Connected Indoor Unit Capacity and Piping Size


Connected Indoor Low Pressure High/Low
Gas Pipe
Model Unit Capacity Gas Pipe Pressure Gas Pipe
(HP) (mm) (mm) (mm)
1.5HP or less ɸ15.88 ɸ12.7 ɸ12.7 T
CH-AP160SSX
1.6 to 4.0 ɸ15.88 ɸ12.7 ɸ15.88
JCH-AP160SSX
4.1 to 6.0 ɸ19.05 ɸ15.88 ɸ15.88
CH-AP280SSX 6.1 to 8.0 ɸ19.05 ɸ15.88 ɸ19.05
JCH-AP280SSX 8.1 to 10.0 ɸ22.2 ɸ19.05 ɸ22.2
T: In case that a branch is located downstream of the CH-Box and also the connected indoor unit capacity is
1.5HP or less, use ɸ15.88 for the gas pipe.

Table 5.2 Piping Connection Size for CH Box


Low Pressure High/Low
Gas Pipe
Model Gas Pipe Pressure Gas Pipe
(mm) (mm) (mm)
CH-AP160SSX
ɸ19.05 ɸ15.88 ɸ15.88
JCH-AP160SSX
CH-AP280SSX
ɸ19.05 ɸ15.88 ɸ19.05
JCH-AP280SSX

Upstream Downstream
Multi-Kit
Low Pressure
Gas Pipe
Gas Pipe
CH-Box
High/Low Pressure
Gas Pipe Indoor Indoor
Unit Unit

P5417023-rev.1 11

2-164 FAN-2209 201709


CH BOX

● Piping Connection
Perform the piping connection according to Table 5.1.

Unit: mm (inch)
Connected Indoor
CH-AP160SSX
Unit Capacity: Q
JCH-AP160SSX
(kW)

(3) Accessory Pipe


(1) Reducer (Cut the expanded part of the pipe end.)
Low Pressure Gas Pipe *1
(2) Accessory Pipe
Q ≤ 6.3 (Field-Supplied) (φ15.88(5/8))
CH-Box
High/Low Pressure Gas Pipe (Upper Surface) Gas Pipe
(Field-Supplied) (φ12.7(1/2)) (Field-Supplied)
(2) Accessory Pipe (φ12.7(1/2))

(3) Accessory Pipe


(1) Reducer (Cut the expanded part of the pipe end.)
Low Pressure Gas Pipe *2
6.3 < Q < 16.0 (Field-Supplied) (φ15.88(5/8)) Field Flaring Work
CH-Box
High/Low Pressure Gas Pipe (Upper Surface) Gas Pipe
(Field-Supplied) (φ12.7(1/2)) (Field-Supplied)
(2) Accessory Pipe (φ15.88(5/8))

(3) Accessory Pipe


*2
Low Pressure Gas Pipe Field Flaring Work
(Field-Supplied) (φ19.05(3/4))
CH-Box
Q = 16.0 High/Low Pressure Gas Pipe (Upper Surface) Gas Pipe
(Field-Supplied) (φ15.88(5/8)) (Field-Supplied)
*2 (φ15.88(5/8))
Field Flaring Work

Unit: mm (inch)
Connected Indoor
CH-AP280SSX
Unit Capacity: Q
JCH-AP280SSX
(kW)

(2) Accessory Pipe


Low Pressure Gas Pipe (2) Accessory Pipe
(Field-Supplied) (φ19.05(3/4)) CH-Box
16.0 < Q ≤ 25.0 High/Low Pressure Gas Pipe (Upper Surface) Gas Pipe
(Field-Supplied) (φ15.88(5/8)) (Field-Supplied)
*2 (φ19.05(3/4))
Field Flaring Work

(2) Accessory Pipe


Low Pressure Gas Pipe
(2) Accessory Pipe
(Field-Supplied) (φ22.2(7/8))
CH-Box
25.0 < Q ≤ 28.0
High/Low Pressure Gas Pipe (Upper Surface) Gas Pipe
(Field-Supplied) (φ19.05(3/4)) (Field-Supplied)
(4) Accessory Pipe (φ22.2(7/8))

*1: Refer to the installation and maintenance manual for the outdoor unit for the following piping size.
• Upstream piping of CH-Box
• Downstream piping of CH-Box when the branch is located downstream of CH-Box.
*2: Refer to Section 5.1 for the flaring work.
NOTE:
The accessory numbers are listed in Table 4.1.

12 P5417023-rev.1

FAN-2209 201709 2-165


CH BOX

(4) Piping Insulation


Unit: mm(inch)

(9) Insulation
(ID 43(1-11/16)) (10) Clamp
(6) Insulation
(8) Insulation
(ID 20(13/16))
(ID 38(1-1/2))
CH-Box
CH-AP160SSX (Upper Surface)
JCH-AP160SSX
(5) Insulation
(ID 16(5/8))
(5) Insulation
(8) Insulation (10) Clamp
(ID 16(5/8))
(ID 38(1-1/2))

(9) Insulation
(ID 43(1-11/16)) (10) Clamp
(7) Insulation
(ID 22(7/8)) (9) Insulation
(ID 43(1-11/16))
CH-AP280SSX CH-Box
(Upper Surface)
JCH-AP280SSX
(5) Insulation
(ID 16(5/8))
(7) Insulation
(8) Insulation (10) Clamp
(ID 22(7/8))
(ID 38(1-1/2))

NOTES:
1. The accessory numbers are listed in Table 4.1.
2. When the humidity inside the ceiling is high, apply additional insulation to the flare nut connection.
Refer to Table 4.2 for more details.

P5417023-rev.1 13

2-166 FAN-2209 201709


CH BOX

6. Electrical Wiring

● LOCK ALL ELECTRICAL POWER SUPPLY SWITCHES IN THE OFF POSITION BEFORE INSTALLING
THE UNIT. FAILURE TO DISCONNECT POWER SUPPLY MAY RESULT IN ELECTRICAL SHOCK OR
EVEN DEATH.
● Turn off the main power switch to the CH-Box, the indoor unit and the outdoor unit before electrical
wiring work or a periodical check is performed.
● Insulate electrical wiring, condensate piping, and electrical components from threats posed by
burrowing animals and temperature extremes. Failure to do so can over time, deteriorate system
performance.
● Secure the cables. External forces on the terminals could lead to a fire.
● Tighten screws according to the following torque.
M4: 1.0 to 1.3 N●m (0.7 to 1.0 ft.lbs) (TB1, TB2)

● Wrap the field-supplied insulation around the wires, and plug the wiring connection hole with the
seal material to protect the product from any condensate water or insects.
● Tightly secure the wires with the cable clamp inside the CH-Box.
● Do not connect the ground wiring to the gas pipe, condensate pipe or lightening conductor.
Gas pipe: An explosion and ignition may occur when gas leaks.
Water pipe: There is no effect of ground wiring when a hard vinyl pipe is used.
Lightning conductor: The ground electric potential abnormally increases when a lightning
conductor is used.

6.1 General Check


(1) Make sure that the field-selected electrical components (main switches, fuses, ELB (Earth Leakage
Breaker), wires, conduit connectors and wire terminals) are properly selected according to the
electrical data indicated in Table 6.1. Make sure that the components comply with National Electrical
Code (NEC).
(2) Communication cable must be a minimum of 18-Gauge, 2-Conductor, Stranded Copper. Shielded
cable must be considered for applications and routing in areas of high EMI and other sources of
potentially excessive electrical noise to reduce the potential for communication errors. When shielded
cabling is applied, proper bonding and termination of the cable shield is required as per HITACHI
guidelines. Plenum and riser ratings for communication cables must be considered per application
and local code requirements.
(3) Use shielded communication cable for communication cable between the indoor and the outdoor unit
(Max. 1,000m (3,281 ft)), and connect the shielded part to the ground screw in the electrical box.
(4) Make sure that the power supply voltage is within ±10% of the rated voltage.
(5) Check the capacity of the electrical wiring. If the power supply capacity is too low, the system cannot
be started due to the voltage drop.
(6) Make sure that the ground wiring is connected.

14 P5417023-rev.1

FAN-2209 201709 2-167


CH BOX

6.2 Electrical Wiring Connection


(1) Perform the electrical wiring work for the CH-Boxes. Select the wire size according to the table below.
(2) Pay attention to the marks on the terminal block when connecting wires for CH-Box and
I.U./O.U. Refer to “Example of Electrical Wiring” for the wiring connection on the next page.

Table 6.1 Electrical Data and Recommended Wiring, Breaker Size


1 Earth Leakage
2 Main Switch 3 Minimum Wire Thickness [mm2]
Breaker (ELB)
Earth Maximum
Power Nominal
Model Nominal Nominal Wire 4 Power Source 5 Transmitting Current
Supply Sensitive Fuse
Current Current Size Cable Size Cable Size
Current
[A] [mA] [A] [A] [mm2] EN60 335-1 1 MLFC 2 EN60 335-1 1 MLFC 2 [A]

1~/N, 230V, 50Hz


CH-AP160SSX 1~/N, 220-240V, 50Hz
CH-AP280SSX 1~/N, 220V, 60Hz
1~, 208-230V, 60Hz* 15 30 15 15 2.0 0.75 0.5 0.75 0.5 0.1
JCH-AP160SSX 1~, 220V, 60Hz*
JCH-AP280SSX *For Mexico model
only.

NOTES:
1) Follow local codes and regulations when selecting field wires.
2) The wire sizes marked with *1 in the above table are selected at the maximum current of the unit according to the
European Standard, EN60 335-1. Use the wires which are not lighter than the ordinary tough rubber sheathed flexible
cord (code designation H05RN-F) or ordinary polychloroprene sheathed flexible cord (code designation H05RN-F).
3) The wire sizes marked with *2 in the above table are selected at the maximum current of the unit according to the
wire, MLFC (Flame Retardant Polyflex Wire) manufactured by Hitachi Cable Ltd., Japan.
4) Use a shielded cable for the transmitting circuit and connect it to ground.
5) In the case that power cables are connected in series, add each unit maximum current and select wires below.
Selection According to EN60 335-1 Selection According to MLFC (at Cable Temperature of 90oC)
Current i (A) Wire Size (mm2) Current i (A) Wire Size (mm2)
i< 6 0.75 i < 15 0.5 *3: In the case that
6 < i < 10 1 15 < i < 19 0.75 current exceeds 63A,
10 < i < 16 1.5 19 < i < 24 1.25 do not connect cables
16 < i < 25 2.5 24 < i < 34 2 in series.
25 < i < 32 4 34 < i < 47 3.5
32 < i < 40 6 47 < i < 63 5.5
40 < i < 63 10 63 < i < 78 8
63 < i *3 78 < i < 113 14
113 < i < 148 22
148 < i < 179 30

P5417023-rev.1 15

2-168 FAN-2209 201709


CH BOX

6.3 Electrical Wiring


The electrical wiring connection for the CH-Box is shown in Figure 6.1.
(1) Turn OFF the main power switch and take off the electrical box cover of CH-Box.
(2) Connect the power supply wiring to L1 and L2 on the terminal block TB1, and connect ground wiring to
the terminals in the electrical box.
(3) Connect the communication cable to “1”, “2”, “3” and “4” on the terminal block TB2 mounted on PCB1.
(4) Tightly clamp the wires using the cable clamp inside the electrical box.
(5) Attach the electrical box cover after completing the wiring work.

Terminal Block
for Communication

CN1 CN2
Terminal Block
for Power Supply

PCB1 TB1
TB2 PCN1

Ground Wiring

Power Supply Wiring

Cable Clamp

Communication Cable Communication Cable


to Outdoor Unit to Indoor Unit

Screw Size Tightning Torque

Terminal Block for


TB1 M4 1.0 - 1.3 N.m
Power Cable
Terminal Block for
TB2 M4 1.0 - 1.3 N.m
Communication Cable

Connecting Hole for


Connecting Hole for
Power Supply Wiring
Communication Cable

NOTE:
The accessory numbers are listed in Table 4.1.

Figure 6.1 Electrical Wiring Connection

16 P5417023-rev.1

FAN-2209 201709 2-169


CH BOX

• Example of Electrical Wiring

The following figure shows an example of electrical wiring around the CH-Boxes.
Outdoor Unit
Power Supply Outdoor Unit
1~/N~ 230V/50Hz Connect the operating line for
1~/N~ 220-240V/50Hz the outdoor unit to the terminal
1~/N~ 220V/60Hz “1” and “2” of TB2 on the CH-Box.
For Mexico 1~, 208-230V, 60Hz TB2
model only. 1~, 220V, 60Hz 1 2 3 4
Connect the operating line for
CH-Box CH-Box
the indoor unit (exclusive use of
ELB TB1 TB2 TB1 TB2 cooling operation) to the terminal
1 Earth Leakage 3 3 “1” and “2” of TB2 on the CH-Box.
L1 N 1 2 3 4 L1 N 1 2 3 4
Breaker
S

2 Main Switch
Wired
4 Pull Box Controller
5
Operating Line TB2 TB2 TB2 TB2
(Non-pole, DC5V)
2 1 BA 2 1BA 2 1BA 2 1 BA

Indoor Unit Wired Indoor Unit Wired Indoor Unit Indoor Unit
Controller Controller (Exclusive Use of
Cooling Operation)
In case that the multiple indoor units
are connected to the same CH-Box,
the operation mode (cooling/heating)
for the indoor units will be the same.

NOTES:
1. Do not apply excessive voltage to the communication cable DC5V (non-polarity) between the outdoor
unit and the CH-Box, between the CH-Box and the indoor unit or between CH-Boxes.
2. Use 2-Conductor shielded communication cable for the communication cable. (Do not use 3-Conductor
cable or over.)
3. Connect the communication cable for the outdoor unit to terminals “1” and “2” on TB2 in the CH-Box.
4. Connect the communication cable for the indoor unit exclusively for cooling operation to the terminal “1”
and “2” on TB2 in the CH-Box.
5. For a CH-Box in the same refrigerant cycle, an electrical power supply can be supplied by one main
switch.
6. Do not connect the power supply line (220-240V/220V/230V) to the terminal block for transmission line.
7. Connect the ground wiring for the outdoor/indoor units and CH-Box. When ground resistance is less
than 100 ohms, ground wiring work should be performed by the qualified electrician.
8. Do not run the communication cables along with power supply wiring in the CH-Box.
Separate communication cables from the power supply wirings.

6.4 Setting of DIP Switches


DSWs on the PCB1 are set before shipping as NOTE
shown below and no setting is required.
The “n” mark indicates the position of DIP
• DSW1 • DSW4 • DSW5 switches. Figures show setting before shipment.
ON ON ON

1 2 3 4 5 6 1 2 1 2 All indoor and outdoor units must be shut


down prior to attempting to make DIP Switch
adjustments, otherwise, the settings will not
● When introducing high voltage take effect.
ON
to terminals 1 and 2 of TB2,
the fuse on the PCB is open.
In such a case, first, reconnect 1 2
the wiring correctly to TB2, and OFF
then adjust the number 1 pin to
ON for DSW4 and DSW5.

P5417023-rev.1 17

2-170 FAN-2209 201709


CH BOX

7. Test Run

NOTICE
Refrigerant piping and connecting wires should be connected to the same refrigerant cycle system.
If they are connected to the dissimilar refrigerant cycle systems, a malfunction may occur.

● Special Attention Regarding Refrigerant Gas Leakage


The refrigerant R410A is non-toxic and inflammable in its original state.
However, in consideration of a state where the refrigerant leaks into the room, measures against
refrigerant leaks must be taken in small rooms where the tolerable level could be exceeded.
Take countermeasures by installing ventilation devices,etc.
< Calculation of Refrigerant Concentration >
(1) Calculate the total quantity of refrigerant R (kg) charged in the system connecting all the indoor units
of rooms to be air-conditioned.
(2) Calculate the room Volume V (m3) of each room.
(3) Calculate the refrigerant concentration C (kg/m3) of the room according to the following equation.

R: Total Quantity of Charged Refrigerant (kg)


V: Room Volume (m3) = C: Refrigerant Concentration
< 0.42 (kg/m3) for R410A

250

Range below the


200 density
limit of 0.42kg/m3
Room Volume (m3)

(Countermeasures
Not Needed)
150

Range above the limit of


100 0.42kg/m3
(Countermeasures Needed)

50

0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150

Total Quantity Charged of Refrigerant (kg)

Perform a test run according to the “Installation and Maintenance Manual” of the outdoor unit.

● Do not operate the system until all the check points are cleared.
(A) Check to ensure that the electrical resistance is more than 1 megohm by measuring the
resistance between ground and the terminal block in the electrical box. If not, do not operate
the system until the electrical leakage is found and repaired.
(B) Check to ensure that the stop valves of the outdoor unit are fully opened, and then start the
system.
(C) Apply power to the outdoor unit(s) at least 12 hours prior to operation of the system for
preheating of the compressor oil.
● Pay attention to the following items while the system is running.
(A) Do not touch any of the parts by hand at the discharge gas side, since the compressor
chamber and the pipes at the discharge side are heated higher than 90°C (194°F).

18 P5417023-rev.1

FAN-2209 201709 2-171


CH BOX

Table 7.1 Alarm Code


Code Category Content of Abnormality Leading Cause
Incorrect Wiring, Loose Terminals, Disconnected
Abnormal Communication between
03 Communication Communication Cable, Blowout of Fuse, Indoor Unit Power
Indoor Units and Outdoor Units
OFF
2 or More CH-Boxes are Connected between
C1 Incorrect CH-Box Connection
Outdoor Unit and Indoor Unit
9 or More Indoor Units Connected to Single Branch Type CH-Box
C2 Incorrect Indoor Unit Connection Number 7 or More Indoor Units Connected per a Branch of Multiple
Branch Type CH-Box
CH-Box Incorrect Indoor Unit Refrigerant Number Indoor Units of Different Refrigerant Cycle Number are
C3
Setting Connected to CH-Box
Incorrect Connection between CH-Box and
C4 This Outdoor Unit is not compatible with this CH-Box.
Outdoor Units
Indoor Unit is connected to a port that is set to not used for
C5 Incorrect Connection Port Setting
Multiple Branch Type CH-Box.

8. Safety and Control Device Setting


CH-Box
CH-AP160SSX, CH-AP280SSX
Model
JCH-AP160SSX, JCH-AP280SSX
For Control Circuit
Fuse A 5

P5417023-rev.1 19

2-172 FAN-2209 201709


CH BOX

Installation
Manual
for
Cooling / Heating
Change-Over Box
CH-Box

Models:

CH-AP04MSSX
CH-AP08MSSX
CH-AP12MSSX
CH-AP16MSSX

JCH-AP04MSSX
JCH-AP08MSSX
JCH-AP12MSSX
JCH-AP16MSSX

IMPORTANT:

READ AND UNDERSTAND


THIS MANUAL CAREFULLY
BEFORE INSTALLING
THIS CH-BOX.
KEEP THIS MANUAL FOR
FUTURE REFERENCE. P5417025
FAN-2213 201711

FAN-2209 201709 2-173


CH BOX

Interchangeability between Current and New CH-Boxes


● New CH-Box is compatible for the new outdoor unit.
Current CH-Box is compatible for the new outdoor unit with limitation.
Refer to the Technical Manual for the outdoor unit for more details.
Current outdoor unit is compatible with current CH unit only.
(When the New CH-Box is connected to current VRF outdoor unit, the unit will not operate and the wired
controller will display the alarm code “C4“.)

4: Available
4
4
Current CH Unit Current VRF (Heat Recovery)
×: Not Available
×
4
4
New CH-Box New VRF (Heat Recovery)
4
4

● Current and new CH-Boxes can not be used in the same system together.
● Production of current CH unit shall be discontinued. However, it will be supplied for servicing and
maintenance until further notice. Contact us if there are order request for the current CH unit.

P5417025-rev.1 i

2-174 FAN-2209 201709


CH BOX

IMPORTANT NOTICE

● The applicable outdoor unit may be different depending on the product series.
Improper combination causes the unit to malfunction and an alarm will be triggered. Be sure to confirm
with the product catalogue before installation.
● The manufacturer of the product pursues a policy of continuous improvement in the design and
performance of products to meet regulatory requirements and industry standards. Therefore, the
manufacturer reserves the right to revise specifications without notice.
● The manufacturer of the product cannot anticipate every possible circumstance that might involve a
potential hazard.
● This heat pump air conditioner is designed for standard air conditioning applications only. Do not use this
heat pump air conditioner for other purposes, such as drying clothes, refrigerating foods, or for any other
cooling or heating process.
● Do not install the unit outdoors. Do not install the unit in the following places. It may cause a fire,
deformation, corrosion or failure.
* Places where there are high levels of oil mist (including machinery oil).
* Places where there are high alkalinity levels (i.e., chlorine or bromine such as over hot tubs, etc.).
* Places where flammable gases or liquids may be used or generated.
* Places with a high concentration of salts, salty mists or sprays (such as over salt-water aquariums).
* Places with an atmosphere of high nuisance dust. Places with organic solvent atmospheres, such as
painting and cleaning locations.
● Do not install a unit in the place where condensate water can leak onto the unit or electrical device failures
may occur.
● Pay attention to the following points when the unit is installed in a hospital or other facility where
electromagnetic waves generate from medical equipment.
* Do not install the unit in places where electromagnetic waves radiate to the electrical box, wired controller
cable or wired controller.
* Install the unit at least 3m (10 ft) away from electromagnetic waves or interferences such as a radio.
● The installer and system specialist shall secure against leakage according to local regulations or
standards. This system has both high and low pressure refrigerant and, as such, comprises a pressurized
system. Never loosen threaded joints while the system is under pressure and never open pressurized
system parts.
● No part of this manual may be reproduced without written permission.
● It is assumed that this heat pump air conditioner will be operated and serviced by English speaking people.
If this is not the case, the distributor or dealer can provide or add safety, caution and operating signs in the
native language.
● If you have any questions, contact your distributor.
● This manual describes the features of this heat pump air conditioner as well as for other models.
This manual should be considered as a permanent part of the air conditioning equipment and should remain
with the air conditioning equipment.

ii P5417025-rev.1

FAN-2209 201709 2-175


CH BOX

CHECKING PRODUCT RECEIVED

● Upon receiving this product, inspect it for any shipping damage.


Inspect all electrical connections. Connections must be clean and tight at the terminals.
Claims for damage either apparent or concealed, should be filed immediately with the shipping company.
NOTE: Rough handling may dislocate internal components.
● Check the model number, electrical characteristics (power supply, voltage and frequency) and accessories
to determine if they are correct with the ordering and shipping information, to ensure the correct unit has
been shipped.
To minimize the possibility of damage after inspection, the units should be installed and reassembled as
soon as possible.

The standard installation and general use of this unit is explained in this manual.
Although common processes and procedures for installing units are presented in this manual, its use for
installation of units otherwise indicated in this manual is not recommended. Please contact your local agent,
as the occasion arises.
Our liability shall not cover defects arising from the alteration performed by a customer without our consent in
a written form.

SAFETY SUMMARY

Signal Words
● Signal words are used to identify levels of hazard seriousness.
Definitions for identifying hazard levels are provided below with their respective signal words.

DANGER : DANGER indicates a hazardous situation which, if not avoided,


will result in death or serious injury.

WARNING : WARNING indicates a hazardous situation which, if not avoided,


could result in death or serious injury.

CAUTION : CAUTION used with the safety alert symbol, indicates a hazardous situation which,
if not avoided, could result in minor or moderate injury.

NOTICE : NOTICE is used to address practices not related to personal injury.

NOTE : NOTE is useful information for operation or maintenance.

P5417025-rev.1 iii

2-176 FAN-2209 201709


CH BOX

SAFETY SUMMARY

DANGER
● Do not perform installation work, refrigerant piping work, condensate pump, or condensate piping and
electrical wiring connection without referring to the installation manual. If the instructions are not followed,
it may result in a water leakage, electric shock or a fire.
● Use the specified non-flammable refrigerant (R410A) for the outdoor unit in the refrigerant cycle.
Charge only R410A into the unit. Do not charge other materials into the unit such as hydrocarbon
refrigerants (propane), oxygen, flammable gases (acetylene) or poisonous gases when installing,
maintaining and moving the unit. These flammables are extremely dangerous and may cause an
explosion, a fire, or injury. As originally manufactured, this unit contains refrigerant installed by the
manufacturer of the product. The manufacturer of the product uses only refrigerants that have been
approved for use in the unit’s intended country or market. Distributors similarly are only authorized
to provide refrigerants that have been approved for use in the countries or markets they serve. The
refrigerant used in this unit is identified on the unit’s faceplate and/or in the associated manuals. Any
additions of refrigerant into this unit must comply with the country’s requirements with regard to refrigerant
use and should be obtained from distributors. Use of unapproved refrigerant substitutes will void the
warranties and can cause injury or death.
● Do not pour water into the indoor or outdoor unit. These units are equipped with electrical parts.
Exposure to water may cause a serious electrical shock.
● Do not open the service cover or access panel for the indoor or outdoor units without turning OFF the main
power supply.
● Do not touch or adjust safety devices inside the indoor unit or outdoor units. If these devices are touched
or readjusted, it may cause a serious accident.
● Carefully check for escaping refrigerant gas. If there is significant leakage, it can cause difficulty in
breathing. Turn OFF the main switch, and contact your service contractor if refrigerant leakage occurs.
● Make sure that the refrigerant leakage test is performed.
Refrigerant (fluorocarbon) for this unit is incombustible, non-toxic and odorless.
However if the refrigerant is leaked and comes in contact with fire, toxic gas will generate.
Because fluorocarbon is heavier than air, the floor surface will be filled with it, which could cause
suffocation.
● The installer and system specialist shall secure against refrigerant leakage according to local regulations
or standards.
● Use a Earth Leakage Breaker (ELB).
In the event of fault, there is danger of an electric shock or a fire if it is not used.

iv P5417025-rev.1

FAN-2209 201709 2-177


CH BOX

SAFETY SUMMARY

WARNING
● Do not use any sprays such as insecticide, lacquer, hair spray or other flammable gases within
approximately 1.3m (4 ft) from the system.
● If the circuit breaker or fuse is often activated, stop the system and contact your service contractor.
● Check that the ground wiring is securely connected. If the unit is not correctly grounded, it may cause
electric shock. Do not connect the ground wiring to gas piping, condensate piping, lighting conductor or
ground wiring for telephones.
● Before performing any brazing work, check to ensure that there is no flammable material around.
When using refrigerant, be sure to wear leather gloves to prevent injury from cold.
● Insulate electrical wiring, condensate piping, and electrical components from threats posed by burrowing
animals and temperature extremes. Failure to do so can, over time, deteriorate system performance.
● Secure the cables. External forces on the terminals could lead to a fire.
● Tighten the flare nut with a torque wrench in the specified manner. Do not apply excessive force to the
flare nut when tightening. If you do, the flare nut can crack and refrigerant leakage may occur.
● When maintaining, relocating or disposing of the unit, dismantle the refrigerant piping after the compressor
stops.
● Highly dangerous electrical voltages are used in this system. Carefully refer to the wiring diagram and
these instructions when wiring. Improper connections and inadequate grounding can cause serious injury
or death.
● Perform all electrical work in strict accordance with this installation and maintenance manual and all
relevant regulatory standards.
● Use specified cables between units.
● Be sure to install circuit breakers (ground fault interrupter, isolating switch, molded case circuit breaker
and so on), with the specified capacity. Ensure that the wiring terminals are tightened securely to
recommended torque specifications. If a circuit breaker or fuse is frequently activated, shut down the
system and contact your service contractor.
● Clamp electrical wires securely with a cable clamp after all wiring is connected to the terminal block.
In addition, run wires securely through the wiring access channel.
● When installing the power lines, do not apply tension to the cables. Secure the suspended cables at
regular intervals, but not too tightly.
● After stopping operation, be sure to wait at least five minutes before turning off the main power switch.
Otherwise, water leakage or electrical breakdown may result. Disconnect the power supply completely
before attempting any maintenance for electrical parts. Check to ensure that no residual voltage is present
after disconnecting the power supply.
● Insulate the refrigerant pipe connection to prevent condensation.
● Be sure to attach the cover so that it fits securely on the electrical box without any gaps. Secure the cover
with screws.

P5417025-rev.1 v

2-178 FAN-2209 201709


CH BOX

CAUTION
● Do not step on the unit.
● Do not put any foreign material on the unit or inside the unit.
● Provide a strong and correct foundation so that:
● The outdoor unit is not on an incline.
● Abnormal sound does not occur.
● The outdoor unit will not fall down due to a strong wind or earthquake.

NOTICE
● Be careful that moisture, dust, or variant refrigerant compounds not enter the refrigerant system during
installation work. Foreign matter could damage internal components or cause blockages.
● Do not install the indoor unit, outdoor unit, wired controller and cable within approximately 3m (10 ft) of
strong electromagnetic wave radiators such as medical equipment.
● After a long shutdown, apply power to the outdoor unit(s) at least 12 hours prior to operation of the system
for preheating of the compressor oil.

NOTE
● It is recommended that the room is ventilated every three to four hours.
● The heating capacity of the heat pump unit is decreased according to the outdoor air temperature.
Therefore, it is recommended that auxiliary heating equipment be used in the field when the unit is
installed in a low temperature region.

vi P5417025-rev.1

FAN-2209 201709 2-179


CH BOX

TABLE OF CONTENTS

1. Safety Summary .............................................................................................................................................1

2. Structure .........................................................................................................................................................1
2.1 Dimensions.............................................................................................................................................1
2.2 Refrigeration Cycle .................................................................................................................................4
2.3 Necessary Tools and Instrument List for Installation ..............................................................................5

3. Transportation and Handling ...........................................................................................................................6


3.1 Transportation ........................................................................................................................................6
3.2 Handling of CH-Box................................................................................................................................6
3.3 Combination of CH-Box and Indoor Unit ................................................................................................6

4. CH-Box Installation .........................................................................................................................................7


4.1 Factory-Supplied Accessories ................................................................................................................7
4.2 Initial Check ............................................................................................................................................8
4.3 Suspension Bolts....................................................................................................................................9
4.4 Installation ............................................................................................................................................10
4.4.1 Marking of the Positions of the Suspension Bolts and Wiring Connections ...............................10
4.4.2 Mounting and Hanging the CH-Box ............................................................................................10

5. Refrigerant Piping Work ................................................................................................................................ 11


5.1 Refrigerant Piping................................................................................................................................. 11
5.2 Refrigerant Piping Work .......................................................................................................................13

6. Electrical Wiring ............................................................................................................................................21


6.1 General Check .....................................................................................................................................21
6.2 Electrical Wiring Connection ................................................................................................................22
6.3 Electrical Wiring....................................................................................................................................24
6.4 Setting of DIP Switches ........................................................................................................................25

7. Test Run ........................................................................................................................................................26

8. Safety and Control Device Setting ................................................................................................................27

P5417025-rev.1 vii

2-180 FAN-2209 201709


CH BOX

1. Safety Summary

● Do not perform installation work, refrigerant Do not install the CH-Box and cable within
piping work or electrical wiring connection approximately 3m (10 ft) from strong
without referring to our installation manual. electromagnetic wave radiators such as
● Check that the ground wire is securely medical equipment.
connected.
● Connect a fuse of specified capacity.

2. Structure
2.1 Dimensions

CH-AP04MSSX Unit: mm
JCH-AP04MSSX Specifications
CH-AP04MSSX
Model
JCH-AP04MSSX
1/N~, 220-240V, 50Hz
View from P P 1/N~, 220V, 60Hz
1/N~, 230V, 50Hz
Power Supply
67 60 x 3 = 180 Refrigerant Liquid Pipe 1~, 208-230V, 60Hz*
Connections 20 340 1~, 220V, 60Hz*
60
A D C B (4 x ɸ9.52 Flare Nuts) (For Suspension Bolt) *For Mexico model only.
60

198 Input (W) 11.2


155

110 Refrigerant R410A


30

Refrigerant Gas Pipe Net Weight (kg) 14


Connection Connectable Indoor Unit
(For Suspension Bolt)

(4 x ɸ15.88 Flare Nuts) 16.0HP or less


Total Capacity
Indoor Unit Connecting Side Connectable Indoor Unit 6.0HP or less
256

Total Capacity per Branch (Max. 16.0kW)


551 Number of Connectable
1 to 6
Suspension Bracket Indoor Unit per Branch
199 352 4 - (12 x 32) Slotted Hole
86 67 540
Refrigerant Gas Refrigerant Liquid
38 303 38 (High/Low Pressure) Pipe Connection
Electrical Box Pipe Connection (I.D. ɸ12.9)
(I.D. ɸ22.36)
Ground Terminal (M5)
260

(in Electrical Box)


156
60

50
Power Supply Wiring 35 176
42

Control Wiring Connection


Connection (ɸ26) (ɸ26) 180
Refrigerant Gas
(Low Pressure) 244
Pipe Connection
34

(I.D. ɸ25.6)
Outdoor Unit Connecting Side

Figure 2.1 Dimensions of CH-Box

P5417025-rev.1 1

FAN-2209 201709 2-181


CH BOX

Unit: mm
CH-AP08MSSX
JCH-AP08MSSX Specifications
CH-AP08MSSX
Model
JCH-AP08MSSX
1/N~, 220-240V, 50Hz
1/N~, 220V, 60Hz
View from P P 1/N~, 230V, 50Hz
Refrigerant Liquid Pipe Power Supply
67 60 x 7 = 420 1~, 208-230V, 60Hz*
Connections 1~, 220V, 60Hz*
60 (8 x ɸ9.52 Flare Nuts) 20 580
(For Suspension Bolt)
*For Mexico model only.
198 Input (W) 22.4
A D C B E H G F
60
156

Refrigerant Gas
Pipe Connection 110 Refrigerant R410A

30
(8 x ɸ15.88 Net Weight (kg) 25
Flare Nuts)

(For Suspension Bolt)


Indoor Unit Connecting Side Connectable Indoor Unit
30.0HP or less
Total Capacity

256
Connectable Indoor Unit 6.0HP or less
Total Capacity per Branch (Max. 16.0kW)
Suspension Bracket Number of Connectable
4 - (12 x 32) Slotted Hole 1 to 6
551 Indoor Unit per Branch
199 352 780
Refrigerant Gas Refrigerant Liquid
86 67 38 543 38 (High/Low Pressure) Pipe Connection
Pipe Connection (I.D. ɸ12.9)
Electrical Box (I.D. ɸ22.36)
260

Ground Terminal (M5)

156
(in Electrical Box)

60
50

42
Power Supply Wiring 35 176 240 Control Wiring Connection
Connection (ɸ26) 180
(2 x ɸ26)
Refrigerant Gas 244
(Low Pressure)
Pipe Connection
34

(I.D. ɸ28.75)
Outdoor Unit Connecting Side

CH-AP12MSSX
JCH-AP12MSSX Specifications
CH-AP12MSSX
Model
JCH-AP12MSSX
View from P 1/N~, 220-240V, 50Hz
1/N~, 220V, 60Hz
Refrigerant Liquid Pipe Connections
(12 x ɸ9.52 Flare Nuts) P Power Supply
1/N~, 230V, 50Hz
1~, 208-230V, 60Hz*
67 60 x 11 = 660 1~, 220V, 60Hz*
60 20 820 *For Mexico model only.
A D C B E H G F I J K L (For Suspension Bolt) Input (W) 33.6
60
156

198
Refrigerant R410A
110
30

Net Weight (kg) 36


Refrigerant Gas Pipe Connection Connectable Indoor Unit
(For Suspension Bolt)

(12 x ɸ15.88 Flare Nuts) 30.0HP or less


Total Capacity
256

Indoor Unit Connecting Side Connectable Indoor Unit 6.0HP or less


Total Capacity per Branch (Max. 16.0kW)
Suspension Bracket
Number of Connectable
551 4 - (12 x 32) Slotted Hole 1 to 6
Indoor Unit per Branch
199 352
1020
Refrigerant Gas Refrigerant Liquid
86 67 38 783 38 (High/Low Pressure) Pipe Connection
Pipe Connection (I.D. ɸ16.1)
Electrical Box (I.D. ɸ25.6)
260

Ground Terminal (M5)


156

(in Electrical Box)


60

50
42

Power Supply Wiring 35 176 240 240 Control Wiring Connection 180
Connection (ɸ26) (3 x ɸ26) Refrigerant Gas
(Low Pressure) 244
Pipe Connection
34

(I.D. ɸ28.75)
Outdoor Unit Connecting Side

Figure 2.2 Dimensions of CH-Box

2 P5417025-rev.1

2-182 FAN-2209 201709


CH BOX

Unit: mm
CH-AP16MSSX
JCH-AP16MSSX Specifications
CH-AP16MSSX
Model
JCH-AP16MSSX
View from P 1/N~, 220-240V, 50Hz
Refrigerant Liquid Pipe Connections 1/N~, 220V, 60Hz
(16 x ɸ9.52 Flare Nuts) 1/N~, 230V, 50Hz
Power Supply
67 900 1~, 208-230V, 60Hz*
60 P 1~, 220V, 60Hz*
*For Mexico model only.
A D C B E H G F I J K O N M L P
Input (W) 44.8
60
156

20 1060
(For Suspension Bolt)
Refrigerant R410A
198
Refrigerant Gas Pipe Connection 110 Net Weight (kg) 47

30
(16 x ɸ15.88 Flare Nuts) Connectable Indoor Unit
30.0HP or less
Indoor Unit Connecting Side Total Capacity

(For Suspension Bolt)


256 Connectable Indoor Unit 6.0HP or less
Total Capacity per Branch (Max. 16.0kW)
Suspension Bracket Number of Connectable
551 1 to 6
4 - (12 x 32) Slotted Hole Indoor Unit per Branch
199 352
1260 Refrigerant Gas Refrigerant Liquid
86 67 38 1023 38 (High/Low Pressure) Pipe Connection
Electrical Box Pipe Connection (I.D. ɸ19.3)
(I.D. ɸ28.75)
260

Ground Terminal (M5)

156
(in Electrical Box)

60
35 176 240 240 240 50

42
Power Supply Wiring Control Wiring Connection
180
Connection (ɸ26) (4 x ɸ26) Refrigerant Gas
(Low Pressure) 244
Pipe Connection
(I.D. ɸ32)
34

Outdoor Unit Connecting Side

Figure 2.3 Dimensions of CH-Box

P5417025-rev.1 3

FAN-2209 201709 2-183


CH BOX

2.2 Refrigeration Cycle

CH-AP04MSSX CH-AP08MSSX
JCH-AP04MSSX JCH-AP08MSSX
G (High/Low Pressure) G (High/Low Pressure)
G (Low Pressure) G (Low Pressure)
L L
To Outdoor Unit Side To Outdoor Unit Side
2 2
1
S S S S

1 1
1

<MVD4>

<MVD3>

<MVD2>

<MVD1>

<MVD4>

<MVD3>

<MVD2>

<MVD1>
<MVD4>

<MVD3>

<MVD2>

<MVD1>

<MVS4>

<MVS3>

<MVS2>

<MVS1>

<MVS4>

<MVS3>

<MVS2>

<MVS1>
<MVS4>

<MVS3>

<MVS2>

<MVS1>

S S S S S S S S S S S S
2 2

L L L L L L L L L L L L
G G G G G G G G G G G G
Unit D Unit C Unit B Unit A Unit H Unit G Unit F Unit E Unit D Unit C Unit B Unit A

To Indoor Unit Side To Indoor Unit Side

CH-AP12MSSX
JCH-AP12MSSX
G (High/Low Pressure)
G (Low Pressure)
L

2 To Outdoor Unit Side

S S

1
<MVD4>

<MVD3>

<MVD2>

<MVD1>

<MVD4>

<MVD3>

<MVD2>

<MVD1>

<MVD4>

<MVD3>

<MVD2>

<MVD1>
<MVS4>

<MVS3>

<MVS2>

<MVS1>

<MVS4>

<MVS3>

<MVS2>

<MVS1>

<MVS4>

<MVS3>

<MVS2>

<MVS1>

S S S S S S S S S S S S
2

L L L L L L L L L L L L
G G G G G G G G G G G G
Unit L Unit K Unit J Unit I Unit H Unit G Unit F Unit E Unit D Unit C Unit B Unit A

To Indoor Unit Side

Mark Part Name G : Refrigerant Gas Pipe Connection


1 Electronic Expansion Valve L : Refrigerant Liquid Pipe Connection
: Field Refrigerant Piping
2 Strainer : Flare Connection
: Brazing Connection
: CH-Box

Figure 2.4 Refrigeration Cycle Diagram

4 P5417025-rev.1

2-184 FAN-2209 201709


CH BOX

CH-AP16MSSX
JCH-AP16MSSX

G (High/Low Pressure)
2 G (Low Pressure) 1
L Outdoor Unit Side

S S
<MVD4>

<MVD3>

<MVD2>

<MVD1>

<MVD4>

<MVD3>

<MVD2>

<MVD1>

<MVD4>

<MVD3>

<MVD2>

<MVD1>

<MVD4>

<MVD3>

<MVD2>

<MVD1>
<MVS4>

<MVS3>

<MVS2>

<MVS1>

<MVS4>

<MVS3>

<MVS2>

<MVS1>

<MVS4>

<MVS3>

<MVS2>

<MVS1>

<MVS4>

<MVS3>

<MVS2>

<MVS1>
S S S S S S S S S S S S S S S S

2
L L L L L L L L L L L L L L L L

G G G G G G G G G G G G G G G G
Unit P Unit O Unit N Unit M Unit L Unit K Unit J Unit I Unit H Unit G Unit F Unit E Unit D Unit C Unit B Unit A

Indoor Unit Side

G : Refrigerant Gas Pipe Connection


Mark Part Name
L : Refrigerant Liquid Pipe Connection
1 Electronic Expansion Valve : Field Refrigerant Piping
: Flare Connection
2 Strainer : Brazing Connection
: CH-Box

Figure 2.5 Refrigeration Cycle Diagram

2.3 Necessary Tools and Instrument List for Installation

No. Tool No. Tool


1 Handsaw 11 Wrench
2 Phillips Screwdriver 12 Charging Cylinder
3 Vacuum Pump 13 Manifold Gauge
4 Refrigerant Gas Hose 14 Wire Cutter
5 Megohmmeter 15 Gas Leak Detector
6 Copper Pipe Bender 16 Level
7 Manual Water Pump 17 Crimper for Solderless Terminals
8 Pipe Cutter 18 Hoist (for Indoor Unit)
9 Brazing Kit 19 Ammeter
10 Hex Wrench 20 Voltage Meter
NOTE:
Use tools and measuring instruments (vacuum pump, refrigerant hose, charging cylinder, and manifold
gauge) exclusively for the refrigerant R410A.

P5417025-rev.1 5

FAN-2209 201709 2-185


CH BOX

3. Transportation and Handling

3.1 Transportation 3.2 Handling of CH-Box


Transport the product as close to the installation
location as practicable before unpacking.
Do not put any foreign material into the indoor
unit and check to ensure that none exists in
Do not put any material on the product. the CH-Box before the installation and test run.
Otherwise, a fire or failure, or something similar
may occur.

Be careful not to damage insulation materials


of unit’s surface when lifting.

3.3 Combination of CH-Box and Indoor Unit


Combination is as follows.

Table 3.1 Combination of Indoor Unit

CH-AP04MSSX CH-AP08MSSX CH-AP12MSSX CH-AP16MSSX


Model
JCH-AP04MSSX JCH-AP08MSSX JCH-AP12MSSX JCH-AP16MSSX
Number of Branches (for Indoor Unit) 4 8 12 16

Maximum Total Capacity of 16.0HP or less 30.0HP or less 30.0HP or less 30.0HP or less
All Connected Indoor Units (Max. 44.8kW) (Max. 85.0kW) (Max. 85.0kW) (Max. 85.0kW)
Single Unit
Per Branch Maximum Total Capacity of
6.0HP or less 6.0HP or less 6.0HP or less 6.0HP or less
Connected Indoor Units Per
(Max. 16.0kW) (Max. 16.0kW) (Max. 16.0kW) (Max. 16.0kW)
Branch
Maximum Number of
Connected Indoor Units Per 6 6 6 6
Branch
Multiple Units
Maximum Total Capacity of 16.0HP or less 30.0HP or less 30.0HP or less 30.0HP or less
Per Branch
All Connected Indoor Units (Max. 44.8kW) (Max. 85.0kW) (Max. 85.0kW) (Max. 85.0kW)
(*1)
Maximum Total Capacity of
6.0HP or less 6.0HP or less 6.0HP or less 6.0HP or less
Connected Indoor Units Per
(Max. 16.0kW) (Max. 16.0kW) (Max. 16.0kW) (Max. 16.0kW)
Branch
(*1) When multiple indoor units are connected to the same branch of CH-Box, they are controlled with the
same operation mode.
NOTES:
1. Exceeding the total capacity may cause insufficient performance and abnormal sound. Be sure to
connect the CH-Box within the allowable total capacity.
2. In case of 8HP or 10HP type indoor unit connection:
Only single unit per branch is allowed to be connected.
Up to two 8HP or 10HP type indoor units can be connected to the CH-Box within the “Maximum Total
Capacity of All Connected Indoor Units” shown in above table.
Make sure to increase the pipe connection size by using the appropriate accessory pipe.

6 P5417025-rev.1

2-186 FAN-2209 201709


CH BOX

4. CH-Box Installation

4.1 Factory-Supplied Accessories


Check to ensure that the following accessories are
● Do not install the CH-Box in a flammable packed with the CH-Box.
environment to avoid fire or an explosion.

NOTE
If any of these accessories are not packed with the
● Check to ensure that the ceiling slab is strong unit, please contact your distributor.
enough.
● Do not install the CH-Box outdoors.
If installed outdoors, an electric hazard or
electric leakage may occur.
● Installation WARNING: Ensure that all safety
features, disconnects and interlocks are
in place and functioning properly prior to
putting the equipment into operation. Never
by-pass or jump-out any safety device or
switch.

Table 4.1 Factory-Supplied Accessories


Unit: mm (inch)
CH-AP04MSSX CH-AP08MSSX CH-AP12MSSX CH-AP16MSSX
No. Accessory Q’ty Q’ty Q’ty Q’ty
JCH-AP04MSSX JCH-AP08MSSX JCH-AP12MSSX JCH-AP16MSSX
ID f12.7 (1/2)

(1) 4 8 12 16
Flaring
f15.88 (5/8)
ID f6.35 (1/4)

(2) 4 8 12 16
Flaring
Accessory f9.52 (3/8)
Pipe ID f19.05 (3/4)

(3) 2 2 2 2
Flaring
Flare Nut Flare Nut Flare Nut Flare Nut
f15.88 (5/8)
ID f22.2 (7/8)

(4) 1 2 2 2
Flaring
Flare Nut Flare Nut Flare Nut Flare Nut
f15.88 (5/8)

ID f26
(5) 4 8 12 16
(1)
Insulation
Material
ID f35
(6) 4 8 12 16
(1-3/8)

(7) Clamp 17 34 51 68

P5417025-rev.1 7

FAN-2209 201709 2-187


CH BOX

4.2 Initial Check


● Install the CH-Box with a proper clearance ● Check to ensure that the ceiling is sufficiently
around it for maintenance working space, as strong to sustain the CH-Box. If the ceiling is
shown in Figure 4.1 below. weak, abnormal sound and vibration may occur.
● When the electronic expansion valve in the
Service Space Unit: mm CH-Box is activated, a change in the typical
refrigerant flow sounds may be heard or
Service Access Door 1 (*) Service Access Door 2
perceived from the CH-Box. Take the following
( 450) ( 450) action to minimize the sound.
(A) Install the CH-Box inside the ceiling. As for
the ceiling material, select a material like a
plasterboard at least 9mm (1 inch), which
50 minimizes operation sound.
50

100
100

(B) Do not install the CH-Box in a place near


bedrooms or hospital rooms.
Electrical Box
● When the operation is changed to cooling/
100

Service Access Door 3 heating mode, a change in the typical refrigerant


( 450)
Min. 300 flow sounds may be heard or perceived from the
CH-Box.
Therefore, install the CH-Box in the ceiling of
4-Suspension Bolt
M10 or W3/8 the corridor so that the refrigerant flowing sound
(Field-Supplied) may not be heard in the room.
Upper Side Min. 100 ● Do not install the CH-Box in a hot or
humid place, such as a kitchen, to prevent
condensation on the outer surface of the
CH-Box.
Min. 500 When installing the CH-Box in such places,
Bottom Side apply additional insulation.
Min. A
Min. 100 ● Pay attention to the following points when the
CH-Box is installed in a hospital or other facility
* Service access door 1 is required for models where there are electronic waves from medical
CH-AP08MSSX, CH-AP12MSSX and CH-AP16MSSX. equipment.
Size (A) Do not install the CH-Box where the
A
Model electromagnetic wave is directly radiated to
CH-AP04MSSX
100 the electrical box or communication cable.
JCH-AP04MSSX
CH-AP08MSSX (B) Install the CH-Box and components as far
JCH-AP08MSSX as practicable or at least 3m (10 ft) from the
CH-AP12MSSX
400 electromagnetic wave radiator.
JCH-AP12MSSX
CH-AP16MSSX (C) Install a noise filter when the power supply
JCH-AP16MSSX emits harmful noises.
● Ensure the installation place is convenient
Purpose of Each Service Access Door for the refrigerant piping or electrical wiring
Name Purpose connection.
Service Access Use during inspection of indoor unit ● Do not drill, or drive screws into the cabinet.
Door 1 connecting side. Use only mounting points provided.
Service Access Use during inspection of indoor unit ● In case the CH-Box is required to move from the
Door 2 connecting side. ceiling, prepare another service access door.
Service Access Use during inspection of electrical
Door 3 components inside electrical box.

Figure 4.1 Service Space

8 P5417025-rev.1

2-188 FAN-2209 201709


CH BOX

4.3 Suspension Bolts


Step 1
(1) Select a final location and installation direction of the CH-Box.
Pay careful attention to the space for the piping, wiring and maintenance.
(2) Mount suspension bolts.
(3) Contact a qualified contractor or carpenter for the ceiling treatment.
View from above Unit: mm (inch)
20 A
(13/16) (For Suspension Bolt)
198
(7-13/16) Size
(1-3/16)

A
110 Model
30

(4-5/16) CH-AP04MSSX
340 (13-3/8)
JCH-AP04MSSX
256 (10-1/16)
For Suspension

CH-AP08MSSX
580 (22-13/16)
JCH-AP08MSSX
CH-AP12MSSX
820 (32-5/16)
Bolt

JCH-AP12MSSX
Suspension Bracket CH-AP16MSSX
1060 (41-3/4)
12 (4-1/2) x 32 (1-1/4) JCH-AP16MSSX
4x
Slotted Hole
Figure 4.2 Position of Suspension Bolts
Step 2
Mount suspension bolts, as shown in Figure 4.3.
 For Steel Beam  For Wooden Beam
Wooden Bar
(60 to 90mm
Antiskid Clamp Suspension Bolt (2-3/8 to 3-9/16 inch) Square)
C-shaped (Bend it) Nut Square
Clamp Wooden Washer
Beam
Nut
Suspension I Beam Nut
Square
Bolt Support Angle Washer
Suspension Bolt Suspension Bolt
Suspension Bolt (M10 or W3/8) (M10 or W3/8)
(M10 or W3/8)

 For Concrete Slab  For Reinforcing Steel


(1) Hole-In Anchor
150 to 160mm
(5-7/8 to 6-5/16 inch)
Part B Part A

Insert
100 to 150 kg
(220 to 331 lbs.)

Steal Concrete

Unit Body Use a hole saw Break a head portion Suspension Bolt
to make a hole. of anchor by using (M10 or W3/8)
a hammer.

Inserting Fixing Fixing Bolt

(2) Resin Capsule Use a suspension bolt with 30 to 45o sloping edge.
Use the resin capsule within the warranty period.
Resin capsules deteriorate over time and should be used within
six mounths of the manufacturing date.

Stiffening Glass
Agent
Stone
Epoxy Resin

Resin Capsule Use a hole saw Inserting Ambient Temp. Time


to make a hole. (with impulse rotation) 20oC (68oF) Min. 30min.
After inserting, do not rotate or put any force until resin is hardened. 15oC (59oF) Min. 1hr.
Required time is as shown in the table at right. 10oC (50oF) Min. 2hr.
5oC (41oF) Min. 4hr.
0oC (32oF) Min. 8hr.

NOTE:
 Use a suspension bolt (W3/8, Metric screw thread: M10).
 Prepare washer and nut.

Figure 4.3 Mounting of Suspension Bolts


P5417025-rev.1 9

FAN-2209 201709 2-189


CH BOX

4.4 Installation
4.4.1 Marking of the Positions of the Suspension (2) Hanging the CH-Box
Bolts and Wiring Connections (a) Hang the CH-Box by putting hands on the
(1) Mark the positions of the suspension bolts, bottom of the cabinet.
refrigerant piping connections and wiring (b) Insert the suspension bolt into the groove
connection. part of the suspension bracket as shown
(2) Installation dimensions are shown in in Figure 4.5. Ensure that the washers
Figure 2.1 and 2.2. are correctly affixed to the suspension
bracket.
(c) After the hanging work, the piping and
4.4.2 Mounting and Hanging the CH-Box wiring connection work is required inside
(1) Place nuts and washers onto the suspension the ceiling in the gap between the roof
bolts before installing the CH-Box. and ceiling so it is not visible. Therefore,
determine the drawing direction of the
NOTE: pipe after selecting the installation location
Make sure to use washers for installing the of the CH-Box. Before doing the hanging
suspension bolts to the suspension brackets. work, carry out the piping and wiring work
Install the washer with the insulation side up to the connecting positions.
facing down for suspended installation (d) Keep the CH-Box level to the ceiling
applications. This way, the washers surface. If the CH-Box is not level, a
themselves remain in position on the malfunction may occur.
suspension bolts during the installation (e) Tighten the nuts of the suspension
phase. bolt with the suspension bracket after
adjustment is completed.
Field-Supplied Parts Adhesive must be applied to the nuts in
* Suspension Bolt: 4-M10 or W3/8 order to prevent them from loosening.
* Nut: 12-M10 or W3/8
* Washer: 4-M10 or W3/8
* Washer with Insulation: 4-M10 or W3/8 Suspension Bolt

Suspension Bolt
(Field-Supplied) Suspension Bracket
Nut (Field-Supplied) (Four Places)

Washer with Insulation


(Field-Supplied)

Suspension Bracket
(Attached Indoor Unit)
1-15/16 inch)
30 to 50mm

Washer (Field-Supplied)
(1-3/16 to

Double-Nut
(Field-Supplied)
Figure 4.5 Hanging Method

Figure 4.4 Suspension

10 P5417025-rev.1

2-190 FAN-2209 201709


CH BOX

5. Refrigerant Piping Work


● Flaring Dimension
Perform the flaring work as shown below.
Use the specified non-flammable refrigerant mm (inch)
90o + 2o
(R410A) for the outdoor unit in the refrigerant +0
Diameter A
cycle. Do not charge material other than 45 o
+ 2o -0.4(-0.02)
(ɸd)
R410A into the unit such as hydrocarbon fA R410A
refrigerants (propane or something similar), 6.35 (1/4) 9.1 (0.36)
oxygen, flammable gases (acetylene or etc.) or 9.52 (3/8) 13.2 (0.52)
1/64 ~ 1/32R
poisonous gases when installing, maintaining 12.7 (1/2) 16.6 (0.65)
and moving. These flammables are extremely 15.88 (5/8) 19.7 (0.78)
dangerous and may cause an explosion, a fire, fd
19.05 (3/4) (T)
and injury.
(T) It is impossible to perform the flaring
work with 1/2H material. In this case,
5.1 Refrigerant Piping use an accessory pipe (with a flare).
(1) Prepare locally-supplied copper pipes.
(2) Select clean copper tubes making sure there
is no dust or moisture inside the tubes.
Before connecting pipes, blow the inside of
the tubes with nitrogen or dry air, to remove ● Cautions for Refrigerant Pipe Work (Example)
any dust or foreign materials. When installing pipe through Do not place the pipe
(3) Select the piping size as shown in the tables the wall, secure a cap at the
end of the pipe.
directly on the ground.
below. Furthermore, check for the flare Correct Incorrect Correct Incorrect
nut and flaring dimension according to the
following figure and table.
Hole Hole

● Joint Selection Attach a cap


Attach a cap
When using 1/2H material and the flaring work or vinyl tape.
or vinyl tape.

is not available. In this instance, use a joint


selected from the chart below. Correct Incorrect

Minimum Thickness of Joint mm(inch) Rain water can


enter.
Diameter R410A
6.35 (1/4) 0.5 (0.020)
9.52 (3/8) 0.6 (0.024) Attach a cap
or vinyl bag with
12.7 (1/2) 0.7 (0.028) rubber band.
15.88 (5/8) 0.8 (0.031)
19.05 (3/4) 0.8 (0.031)
22.2 (7/8) 0.9 (0.035)
25.4 (1) 0.95 (0.037)
28.58 (1-1/8) 1.0 (0.039)
31.75 (1-1/4) 1.1 (0.043)
38.1 (1-1/2) 1.35 (0.053)
41.28 (1-5/8) 1.45 (0.057)

Flare Nut Dimension B mm(inch)


Flare Nut
Diameter R410A
6.35 (1/4) 17 (11/16)
9.52 (3/8) 22 (7/8)
12.7 (1/2) 26 (1) B

15.88 (5/8) 29 (1-1/8)


19.05 (3/4) 36 (1-7/16)

NOTE:
Do not use a joint other than those specified in
the table above.

P5417025-rev.1 11

FAN-2209 201709 2-191


CH BOX

● Cautions for Piping Connection Work


(a) Connect the indoor/outdoor connecting
pipes. Secure the pipes and do not touch ● Do not apply excessive force to the flare
other objects, such as ceilings for example. nut when tightening. Excessive force can
(Otherwise, abnormal sound may be heard result in the flare nut cracking and refrigerant
due to the vibration of the piping.) leakage may occur. Use the specified
(b) Apply refrigerant oil slightly on the sheet tightening torque.
surface of the pipe and flare nut before the ● For more details of the refrigerant piping
flaring work. Then tighten the flare nut with work, vacuum pumping and refrigerant
the specified tightening torque using two charge, refer to the Technical Manual for the
wrenches. Always use a back-up wrench to Outdoor Unit.
prevent twisting of the copper piping within
the unit assembly. Perform the flaring work
on the liquid piping side before the gas
piping side. Check the gas leakage after the
flaring work.
NOTE:
Refrigerant oil is field-supplied.
[Ethereal Oil FVC50K, FVC68D (Idemitsu
Kousan Co. Ltd.)]
(c) When temperature and humidity inside the
ceiling exceed 27oC(80oF) /RH, relative
humidity, 80%, apply additional insulation
approximately 20mm (13/16 inch) thickness
to the accessory insulation. It prevents
condensation on the surface of the insulation
(refrigerant pipe only) and possible damage
to electronic components.
(d) Perform the air-tight leakage test 4.15MPa
(601 psi) for the test pressure. Refer to the
Technical Manual for the Outdoor Unit for
more details.
(e) Perform cold insulation work by insulating
and taping the flare connection and reducer
connection. Also insulate all the refrigerant
pipes.

Apply Refrigerant Oil.

Two wrenches required to prevent


damaging the copper piping.

Required Tightening Torque


Pipe Size Tightening Torque
6.35mm (ɸ1/4 inch) 14 to 18 N●m (10.3 to 13.3 ft.lbs)
9.52mm (ɸ3/8 inch) 34 to 42 N●m (25.1 to 31.0 ft.lbs)
12.7mm (ɸ1/2 inch) 49 to 61 N●m (36.1 to 45.0 ft.lbs)
15.88mm (ɸ5/8 inch) 68 to 82 N●m (50.2 to 60.5 ft.lbs)
19.05mm (ɸ3/4 inch) 100 to 120 N●m (73.8 to 88.5 ft.lbs)

12 P5417025-rev.1

2-192 FAN-2209 201709


CH BOX

5.2 Refrigerant Piping Work


Provide the refrigerant pipe in the field.
Make sure that the refrigerant pipe is connected to the same refrigerant cycle unit.
(1) Position of Piping Connection

* a Unit: mm (inch)
260
(10-1/4)

198
Refrigerant Liquid Pipe
(7-13/16)

(7-13/16)

(1-15/16)
Connection for Outdoor Unit
199

110
(3-3/8)

50
I.D. φD
86

(4-5/16)

(7-1/16)
551 (21-11/16)

180
352 (13-7/8)

(9-5/8)
244
Refrigerant Gas (Low Pressure)
Pipe Connection for Outdoor Unit
Refrigerant Gas (High/Low Pressure) 42
(2-5/8)

Electrical Box I.D. φC


Pipe Connection for Outdoor Unit (1-5/8)
67

60
I.D. φB
(2-3/8)
A
156
(6-1/8)

Unit: mm (inch)
Dimension
A B C D
Model
CH-AP04MSSX
303 (11-15/16) 22.2 (7/8) 25.4 (1) 12.7 (1/2)
JCH-AP04MSSX
CH-AP08MSSX
543 (21-3/8) 22.2 (7/8) 28.58 (1/1/8) 12.7 (1/2)
JCH-AP08MSSX
CH-AP12MSSX
783 (30-13/16) 25.4 (1) 28.58 (1/1/8) 15.88 (5/8)
JCH-AP12MSSX
CH-AP16MSSX
1023 (40-9/32) 28.58 (1-1/8) 31.75 (1-1/4) 19.05 (3/4)
JCH-AP16MSSX

View of Indoor Unit Connecting Side * a

CH-AP04MSSX CH-AP12MSSX
JCH-AP04MSSX JCH-AP12MSSX
Refrigerant Gas Pipe Connection Refrigerant Gas Pipe Connection
for Indoor Unit for Indoor Unit
(2-3/8)

(12 x φ15.8 (5/8) Flare Nut)

156 (2-3/8)
(4 x φ15.8 (5/8) Flare Nut)
60

60
(6-1/8)

(6-1/8)
156


ࠉ Refrigerant Liquid Pipe
Refrigerant Liquid Pipe D C B A Connection for Indoor Unit L K J I H G F E D C B A

Connection for Indoor Unit (12 x φ9.52 (3/8) Flare Nut) 60


60
(4 x φ9.52 (3/8) Flare Nut) (2-3/8) (2-3/8)
60 x 11 = 660 67
60 x 3 = 180 67
(2-3/8 x 11 = 26) (2-5/8)
(2-3/8 x 3 = 7-1/16) (2-5/8)

CH-AP08MSSX CH-AP16MSSX
JCH-AP08MSSX JCH-AP16MSSX
Refrigerant Gas Pipe Connection Refrigerant Gas Pipe Connection
for Indoor Unit for Indoor Unit
(2-3/8)

(8 x φ15.8 (5/8) Flare Nut) (16 x φ15.8 (5/8) Flare Nut)


156 (2-3/8)
60

60
(6-1/8)

(6-1/8)
156

Refrigerant Liquid Pipe H G F E D C B A P O N M L K J I H G F E D C B A


Connection for Indoor Unit Refrigerant Liquid Pipe 60
60 Connection for Indoor Unit

(8 x φ9.52 (3/8) Flare Nut) (2-3/8) (2-3/8)
(16 x φ9.52 (3/8) Flare Nut) 60 x 15 = 900
60 x 7 = 420 67 67
(2-3/8 x 7 = 16-9/16) (2-5/8) (2-3/8 x 15 = 35-7/16) (2-5/8)

P5417025-rev.1 13

FAN-2209 201709 2-193


CH BOX

(2) Piping Work for CH-Box


Refer to Technical Catalogue and Installation Manual of the outdoor unit for the piping diameter and
the installation condition.
(3) Selecting Piping Size
● Select the size for the high/low pressure gas pipe, (a) Outdoor Unit Connecting Side
low pressure gas pipe and liquid pipe according
High/Low Pressure
to Table 5.1. The size depends on the indoor unit Gas Pipe (B)
total capacity connected downstream of the (Field-Supplied)
CH-Box.
● As for the multi-kit branch or header branch, refer Low Pressure
Gas Pipe (A)
to the Technical Catalog for the Outdoor Unit.
(Field-Supplied)
● Perform the piping connection work for the CH-Box Liquid Pipe (C)
as shown below. (Field-Supplied)

Gas Pipe (D)


(Field-Supplied)
Liquid Pipe (E)
(Field-Supplied)

(b) Indoor Unit Connecting Side

(a) Outdoor Unit Side Field Piping Size

Table 5.1 Outdoor Unit Side Field Piping Size


Connected Low Pressure High/Low Pressure
Liquid Pipe (C)
Indoor Unit Capacity: Q Gas Pipe (A) Gas Pipe (B)
kW mm (inch) mm (inch) mm (inch)
< 16.0 f15.88 (5/8) f12.7 (1/2) f9.52 (3/8)
16.0 ≤ Q < 25.0 f19.05 (3/4) f15.88 (5/8) f9.52 (3/8)
25.0 ≤ Q < 33.5 f22.2 (7/8) f19.05 (3/4) f9.52 (3/8)
33.5 ≤ Q < 45.0 f25.4 (1) f22.2 (7/8) f12.7 (1/2)
45.0 ≤ Q < 50.0 f28.58 (1-1/8) f22.2 (7/8) f12.7 (1/2)
50.0 ≤ Q < 61.5 f28.58 (1-1/8) f22.2 (7/8) f15.88 (5/8)
61.5 ≤ Q < 73.0 f28.58 (1-1/8) f25.4 (1) f15.88 (5/8)
73.0 ≤ Q ≤ 85.0 f31.75 (1-1/4) f28.58 (1-1/8) f19.05 (3/4)
NOTE:
Refer to “Position of Piping Connection” for the details of the piping connection for the CH-Box.
Use field-supplied reducer in case the field piping and CH-Box piping connection does not match.

14 P5417025-rev.1

2-194 FAN-2209 201709


CH BOX

Details of changes to the piping size for connection to the CH-Box are shown below.

CH-AP04MSSX
JCH-AP04MSSX Unit: mm (inch)
Piping Connection Required
Field-Supplied Remarks
Size for CH-Box Pipe Size
f19.05 OD25.4 ID19.05 Apply Field-Supplied Reducer

(3/4) (1) (3/4) (2 Size Down)
ɸ22.2 OD25.4 ID22.2
→ Apply Field-Supplied Reducer
Low Pressure ɸ25.4 (7/8) (1) (7/8)
Gas Pipe (A) (1) ɸ25.4
- -
(1)
ɸ28.58 OD25.4 ID28.58
→ Apply Field-Supplied Reducer
(1-1/8) (1) (1-1/8)
ɸ12.7 OD22.2 ID12.7 Apply Field-Supplied Reducer

(1/2) (7/8) (1/2) (3 Size Down)
f15.88 OD22.2 ID15.88 Apply Field-Supplied Reducer
High/Low →
ɸ22.2 (5/8) (7/8) (5/8) (2 Size Down)
Pressure
(7/8) f19.05 OD22.2 ID19.05
Gas Pipe (B) → Apply Field-Supplied Reducer
(3/4) (7/8) (3/4)
ɸ22.2
- -
(7/8)
f9.52 OD12.7 ID9.52
→ Apply Field-Supplied Reducer
ɸ12.7 (3/8) (1/2) (3/8)
Liquid Pipe (C)
(1/2) ɸ12.7
- -
(1/2)

CH-AP08MSSX
JCH-AP08MSSX Unit: mm (inch)
Piping Connection Required
Field-Supplied Remarks
Size for CH-Box Pipe Size
f19.05 OD28.58 ID19.05 Apply Field-Supplied Reducer

(3/4) (1-1/8) (3/4) (3 Size Down)
ɸ22.2 OD28.58 ID22.2 Apply Field-Supplied Reducer

(7/8) (1-1/8) (7/8) (2 Size Down)
Low Pressure ɸ28.58 ɸ25.4 OD28.58 ID25.4
→ Apply Field-Supplied Reducer
Gas Pipe (A) (1-1/8) (1) (1-1/8) (1)
ɸ28.58
- -
(1-1/8)
f34.93 OD28.58 ID34.93
→ Apply Field-Supplied Reducer
(1-3/8) (1-1/8) (1-3/8)
f15.88 OD22.2 ID15.88 Apply Field-Supplied Reducer

(5/8) (7/8) (5/8) (2 Size Down)
f19.05 OD22.2 ID19.05
→ Apply Field-Supplied Reducer
(3/4) (7/8) (3/4)
High/Low
ɸ22.2 ɸ22.2
Pressure - -
(7/8) (7/8)
Gas Pipe (B)
ɸ25.4 OD22.2 ID25.4
→ Apply Field-Supplied Reducer
(1) (7/8) (1)
ɸ28.58 OD22.2 ID28.58 Apply Field-Supplied Reducer

(1-1/8) (7/8) (1-1/8) (2 Size Up)
f9.52 OD12.7 ID9.52
→ Apply Field-Supplied Reducer
(3/8) (1/2) (3/8)
ɸ12.7
- -
ɸ12.7 (1/2)
Liquid Pipe (C)
(1/2) f15.88 OD12.7 ID15.88
→ Apply Field-Supplied Reducer
(5/8) (1/2) (5/8)
f19.05 OD12.7 ID19.05 Apply Field-Supplied Reducer

(3/4) (1/2) (3/4) (2 Size Up)

P5417025-rev.1 15

FAN-2209 201709 2-195


CH BOX

CH-AP12MSSX
JCH-AP12MSSX Unit: mm (inch)
Piping Connection Required
Field-Supplied Remarks
Size for CH-Box Pipe Size
ɸ22.2 OD28.58 ID22.2 Apply Field-Supplied Reducer

(7/8) (1-1/8) (7/8) (2 Size Down)
ɸ25.4 OD28.58 ID25.4
→ Apply Field-Supplied Reducer
Low Pressure ɸ28.58 (1) (1-1/8) (1)
Gas Pipe (A) (1-1/8) ɸ28.58
- -
(1-1/8)
f34.93 OD28.58 ID34.93
→ Apply Field-Supplied Reducer
(1-3/8) (1-1/8) (1-3/8)
f19.05 OD25.4 ID19.05 Apply Field-Supplied Reducer

(3/4) (1) (3/4) (2 Size Down)
ɸ22.2 OD25.4 ID22.2
High/Low → Apply Field-Supplied Reducer
ɸ25.4 (7/8) (1) (7/8)
Pressure
(1) ɸ25.4
Gas Pipe (B) - -
(1)
ɸ28.58 OD25.4 ID28.58
→ Apply Field-Supplied Reducer
(1-1/8) (1) (1-1/8)
f9.52 OD15.88 ID9.52 Apply Field-Supplied Reducer

(3/8) (5/8) (3/8) (2 Size Down)
ɸ12.7 OD15.88 ID12.7
→ Apply Field-Supplied Reducer
ɸ15.88 (1/2) (5/8) (1/2)
Liquid Pipe (C)
(5/8) f15.88
- -
(5/8)
f19.05 OD15.88 ID19.05
→ Apply Field-Supplied Reducer
(3/4) (5/8) (3/4)

CH-AP16MSSX
JCH-AP16MSSX Unit: mm (inch)
Piping Connection Required
Field-Supplied Remarks
Size for CH-Box Pipe Size
ɸ22.2 OD31.75 ID22.2 Apply Field-Supplied Reducer

(7/8) (1-1/4) (7/8) (3 Size Down)
ɸ25.4 OD31.75 ID25.4 Apply Field-Supplied Reducer

Low Pressure ɸ31.75 (1) (1-1/4) (1) (2 Size Down)
Gas Pipe (A) (1-1/4) ɸ28.58 OD31.75 ID28.58
→ Apply Field-Supplied Reducer
(1-1/8) (1-1/4) (1-1/8)
f31.75
- -
(1-1/4)
f19.05 OD28.58 ID19.05 Apply Field-Supplied Reducer

(3/4) (1-1/8) (3/4) (3 Size Down)
ɸ22.2 OD28.58 ID22.2 Apply Field-Supplied Reducer
High/Low →
ɸ28.58 (7/8) (1-1/8) (7/8) (2 Size Down)
Pressure
(1-1/8) ɸ25.4 OD28.58 ID25.4
Gas Pipe (B) → Apply Field-Supplied Reducer
(1) (1-1/8) (1)
ɸ28.58
- -
(1-1/8)
f9.52 OD19.05 ID9.52 Apply Field-Supplied Reducer

(3/8) (3/4) (3/8) (3 Size Down)
ɸ12.7 OD19.05 ID12.7 Apply Field-Supplied Reducer

ɸ19.05 (1/2) (3/4) (1/2) (2 Size Down)
Liquid Pipe (C)
(3/4) f15.88 OD19.05 ID15.88
→ Apply Field-Supplied Reducer
(5/8) (3/4) (5/8)
f19.05
- -
(3/4)

16 P5417025-rev.1

2-196 FAN-2209 201709


CH BOX

(b) Indoor Unit Side Field Piping Size


● When a branch is located downstream of the CH-Box
Connected Indoor Unit
Gas Pipe (D) Liquid Pipe (E)
Capacity: (Q)
kW mm (inch) mm (inch)
1 1
Q < 16.0 f15.88 (5/8) f9.52 (3/8)
1
Q = 16.0 f19.05 (3/4) f9.52 (3/8)
1. Field flaring work is required. Refer to Section 5.1 for the flaring work.

● When a branch is not located downstream of the CH-Box


Connected Indoor Unit
Gas Pipe (D) Liquid Pipe (E)
Capacity: (Q) Remarks
kW mm (inch) mm (inch)
Use accessory pipe (1) on gas pipe side
Q ≤ 6.3 f12.7 (1/2) f6.35 (1/4) and accessory pipe (2) on liquid pipe side to
decrease the pipe size.
1 1
7.1 ≤ Q ≤ 16.0 f15.88 (5/8) f9.52 (3/8) -
1 Use accessory pipe (3) on gas pipe side to
Q = 22.4 f19.05 (3/4) f9.52 (3/8)
increase the pipe size.
1 Use accessory pipe (4) on gas pipe side to
Q = 28.0 f22.2 (7/8) f9.52 (3/8)
increase the pipe size.
1. Field flaring work is required. Refer to Section 5.1 for the flaring work.

NOTES:
1. When connecting the Gas Pipe (D) and Liquid Pipe (E), reuse the flare nut attached to the
CH-Box.
2. When the connected indoor unit capacity is 6.3kW or less and the piping length exceeds 15m (49ft.),
use 9.52mm (3/8 inch) for the liquid pipe.

NOTICE
In case the piping connection is not used for the indoor unit side piping connection, it must be
sealed using the closed flare nut originally attached. These flare nuts have been tightened by
torque specifications shown below before shipping. Ensure that they are sealed completely.

P5417025-rev.1 17

FAN-2209 201709 2-197


CH BOX

● Tightening Torque for Flare Nut before shipping


Item Tightening Torque
Gas Pipe Flare Nut 75+7 N●m (55.3+5 ft●lbs)
Liquid Pipe Flare Nut 38+4 N●m (28.0+3 ft●lbs)

NOTICE
1. In case of 8 and 10HP type indoor unit connection:
Up to two 8 and 10HP type indoor units can be connected to the CH-Box within the “Maximum
Total Capacity of All Connected Indoor Units”. Make sure to increase the pipe connection size by
using the appropriate accessory pipe.
2. In case of 8 and 10HP type indoor unit connection:
Only single unit per branch is allowed to be connected.
3. In case the number of indoor unit connection is less and the piping connections are left over:
● Unused piping connections must be sealed using the
closed flare nut originally attached.
It is unnecessary to attach closed-end piping.
Refrigerant leakage is caused by loosened flare nuts. CH-Box
Ensure that they are sealed completely.
Use specified tightening torque according to the table
“Tightening Torque for Flare Nut before shipping”
above.
● Any piping connections can be left over. Example;
4. In case there is plan for additional indoor units in the Use three In case one of the
connection ports. piping connection is
future: unused, ensure the
● Do not plan the piping size for additional indoor closed flare nut originally
attached is secured.
units. Ensure to select the piping again in the future. (For gas and liquid sides)
● Additional indoor units can be connected only after Above figure illustrate the example of CH-AP04MSSX.
the refrigerant is recovered.

(4) Piping Insulation

(a) After the air-tight leakage test, perform insulation work as shown below.

Upstream (Outdoor Unit Side)


Insulation Clamp (Two each)
(Field-Supplied) (Field-Supplied)

High/Low Pressure Gas Pipe


Low Pressure Gas Pipe Clamp
CH-Box
(Accessory)
Liquid Pipe
Insulation
Insulation Insulation
(Field-Supplied) (Accessory)
Insulation
Clamp (Accessory)
(Field-Supplied)
Insulation
(Field-Supplied) Liquid Pipe
Gas Pipe

Downstream (Indoor Unit Side)

18 P5417025-rev.1

2-198 FAN-2209 201709


CH BOX

(b) Insulate gas and liquid pipe separately using the accessory insulation material.
In the event that temperature and humidity levels inside the ceiling exceed 30°C (86oF)/RH, relative
humidity 80%, apply additional insulation materials (approximately 10mm (3/8 inch) thickness) to the
surface of the accessory insulation material to avoid condensation.
(c) Perform cold insulation work by insulating and taping the flare connection and reducer connection.
Also insulate all the refrigerant pipes.

Check that there are no gaps between Check there are no gaps between insulation materials.
the CH-Box and the insulation. If the gaps are occurs, seal the gap with vinyl tape.

Apply by making Insulation Material


contact to the piping. Insulation Material
(Attached to the CH-Box) Insulation
(Attached to the CH-Box)
(Accessory (6))
Insulation
(Field-Supplied)

CH-Box Side
CH-Box Side
Insulation Insulation Material Insulation
(Field-Supplied) (Attached to the CH-Box) (Field-Supplied)
Clamp
Securely fasten cable clamps (Accessory (7))
and the vinyl tape (Field-Supplied). Securely fasten.
Insulation Work for Gas (High/Low Pressure and Low Pressure)
Pipe of Outdoor Unit Side Insulation Work for Gas Pipe of Indoor Unit Side

Check that there are no gaps between Check that there are no gaps between
the CH-Box and the insulation. the CH-Box and the insulation.

Apply by making Insulation Material


contact to the piping. (Attached to the CH-Box)
Insulation Material
Insulation (Attached to the CH-Box)
Insulation
(Field-Supplied)
(Accessory (5))
CH-Box Side

CH-Box Side

Insulation Insulation
(Field-Supplied) (Field-Supplied)
Securely fasten cable clamps Clamp
and the vinyl tape (Field-Supplied). (Accessory (7)) Securely fasten.

Insulation Work for Liquid Pipe of Outdoor Unit Side Insulation Work for Liquid Pipe of Indoor Unit Side

(d) In case there are unused piping connection, ensure Insulation


(Accessory (5), (6))
to apply accessory insulation material to the piping
and flare connections without gaps as shown on Insulate without gaps.

the right figure. (For gas and liquid sides)

Clamp
(Accessory (7)) Securely fasten.

P5417025-rev.1 19

FAN-2209 201709 2-199


CH BOX

6. Electrical Wiring

● LOCK ALL ELECTRICAL POWER SUPPLY SWITCHES IN THE OFF POSITION BEFORE INSTALLING
THE UNIT. FAILURE TO DISCONNECT POWER SUPPLY MAY RESULT IN ELECTRICAL SHOCK OR
EVEN DEATH.
● Turn off the main power switch to the CH-Box, the indoor unit and the outdoor unit before electrical
wiring work or a periodical check is performed.
● Insulate electrical wiring, condensate piping, and electrical components from threats posed by
burrowing animals and temperature extremes. Failure to do so can over time, deteriorate system
performance.
● Secure the cables. External forces on the terminals could lead to a fire.
● Be sure to attach the cover so that it fits securely on the electrical box without any gaps.
Secure the cover with screws.
● Tighten screws according to the following torque.
M4: 1.0 to 1.3 N.m (0.7 to 1.0 ft.lbs) (TB1, TB2, TB3, TB4)

● Wrap the field-supplied insulation around the wires, and plug the wiring connection hole with the
seal material to protect the product from any condensate water or insects.
● Tightly secure the wires with the cable clamp inside the CH-Box.
● Do not connect the ground wiring to the gas pipe, condensate pipe or lightening conductor.
Gas pipe: An explosion and ignition may occur when gas leaks.
Water pipe: There is no effect of ground wiring when a hard vinyl pipe is used.
Lightning conductor: The ground electric potential abnormally increases when a lightning
conductor is used.

6.1 General Check


(1) Make sure that the field-selected electrical components (main switches, fuses, ELB (Earth Leakage
Breaker), wires, conduit connectors and wire terminals) are properly selected according to the
electrical data indicated in Table 6.1. Make sure that the components comply with National Electrical
Code (NEC).
(2) Communication cable must be a minimum of 18-Gauge, 2-Conductor, Stranded Copper. Shielded
cable must be considered for applications and routing in areas of high EMI and other sources of
potentially excessive electrical noise to reduce the potential for communication errors. When shielded
cabling is applied, proper bonding and termination of the cable shield is required as per HITACHI
guidelines. Plenum and riser ratings for communication cables must be considered per application
and local code requirements.
(3) Use shielded communication cable for communication cable between the indoor and the outdoor unit
(Max. 1,000m (3,281 ft)), and connect the shielded part to the ground screw in the electrical box.
(4) Make sure that the power supply voltage is within ±10% of the rated voltage.
(5) Check the capacity of the electrical wiring. If the power supply capacity is too low, the system cannot
be started due to the voltage drop.
(6) Make sure that the ground wiring is connected.

20 P5417025-rev.1

2-200 FAN-2209 201709


CH BOX

6.2 Electrical Wiring Connection


(1) Perform the electrical wiring work for the CH-Boxes. Select the wire size according to the table below.
(2) Pay attention to the marks on the terminal block when connecting wires for CH-Box and I.U./O.U.
Refer to “Example of Electrical Wiring” for the wiring connection on the next page.

Table 6.1 Electrical Data and Recommended Wiring, Breaker Size


1 Earth Leakage
2 Main Switch 3 Minimum Wire Thickness [mm2]
Breaker (ELB)
Earth Maximum
Power Nominal
Model Nominal Nominal Wire 4 Power Source 5 Transmitting Current
Supply Sensitive Fuse
Current Current Size Cable Size Cable Size
Current
2 1 2
[A] [mA] [A] [A] [mm ] EN60 335-1 MLFC EN60 335-1 1 MLFC 2 [A]
CH-AP04MSSX
0.2
JCH-AP04MSSX 1/N~, 220-240V, 50Hz
CH-AP08MSSX 1/N~, 220V, 60Hz
1/N~, 230V, 50Hz 0.4
JCH-AP08MSSX
1~, 208-230V, 60Hz* 15 30 15 15 2.0 0.75 0.5 0.75 0.5
CH-AP12MSSX 1~, 220V, 60Hz* 0.6
JCH-AP12MSSX *For Mexico model
CH-AP16MSSX only.
0.8
JCH-AP16MSSX

NOTES:
1) Follow local codes and regulations when selecting field wires.
2) The wire sizes marked with *1 in the above table are selected at the maximum current of the unit according to the
European Standard, EN60 335-1. Use the wires which are not lighter than the ordinary tough rubber sheathed flexible
cord (code designation H05RN-F) or ordinary polychloroprene sheathed flexible cord (code designation H05RN-F).
3) The wire sizes marked with *2 in the above table are selected at the maximum current of the unit according to the
wire, MLFC (Flame Retardant Polyflex Wire) manufactured by Hitachi Cable Ltd., Japan.
4) Use a shielded cable for the transmitting circuit and connect it to ground.
5) In the case that power cables are connected in series, add each unit maximum current and select wires below.
Selection According to EN60 335-1 Selection According to MLFC (at Cable Temperature of 90oC)
Current i (A) Wire Size (mm2) Current i (A) Wire Size (mm2)
i< 6 0.75 i < 15 0.5 *3: In the case that
6 < i < 10 1 15 < i < 19 0.75 current exceeds 63A,
10 < i < 16 1.5 19 < i < 24 1.25 do not connect cables
16 < i < 25 2.5 24 < i < 34 2 in series.
25 < i < 32 4 34 < i < 47 3.5
32 < i < 40 6 47 < i < 63 5.5
40 < i < 63 10 63 < i < 78 8
63 < i *3 78 < i < 113 14
113 < i < 148 22
148 < i < 179 30

P5417025-rev.1 21

FAN-2209 201709 2-201


CH BOX

• Example of Electrical Wiring

The following figure shows an example of electrical wiring around the CH-Boxes.

Outdoor Unit

TB2
H-LINK O.U.-O.U.
1 2 3 4 Connect
communication cable
from outdoor unit
to the outdoor
terminal block (TB2)
in CH-Box.

CH-Box A to L indicate the Indoor Unit number.


CH-AP16MSSX
CH-AP12MSSX CH-Box
CH-AP08MSSX
CH-AP04MSSX PCB1
PCB1 PCB2 PCB3 PCB4 TB2 TB3 TB4
TB1 TB2 TB3 TB4 TB3 TB4 TB3 TB4 TB3 TB4 Outdoor Indoor Indoor
Power Indoor Indoor Indoor Indoor Indoor Indoor Indoor Indoor 3 A B C
3 Supply Outdoor 1 2 3 4 5 6 7 8
R/ S/
A B C D E F G H I J K L M N O P
L1 L2 1 2 3 4 5 6 7 8 9 10 3 4 5 6 7 8 9 10 3 4 5 6 7 8 9 10 3 4 5 6 7 8 9 10
Connect communication
cable from cooling only
1 indoor unit to the outdoor
Earth 2 terminal block (TB2) in
Outdoor Unit Leakage Main Switch 5 Communication Cable CH-Box.
Power Supply Breaker and Fuse (Non-Polarity)
1~/N 230V/50Hz (DC5V)
1~/N 220-240V/50Hz
ELB S
TB2 TB2 TB2 TB2 TB2
1~/N 220V/60Hz WC WC
WC B A 2 1 B A 2 1 B A 2 1 WC B A 2 1
For Mexico 1~, 208-230V/50Hz WC B A 2 1
model only. 1~, 220V/60Hz 4 Power Supply Wiring
Indoor Unit A Indoor Unit B Indoor Unit L 1 Indoor Unit L2
Communication Cable Cooling Only Indoor Unit
(Non-Polarity) When multiple indoor units are connected to the same branch of CH-Box,
(DC5V)
the operation mode (cooling/heating) for the indoor units will be the same.
WC: Wired Controller

NOTES:
1. Do not apply excessive voltage to the communication cable DC5V (non-polarity) between the outdoor
unit and the CH-Box, between the CH-Box and the indoor unit or between CH-Boxes.
2. Use 2-Conductor shielded communication cable for the communication cable. (Do not use 3-Conductor
cable or over.)
3. Connect the communication cable for the outdoor unit to terminals “1” and “2” on TB2 in the CH-Box.
4. Connect the communication cable for the indoor unit exclusively for cooling operation to the terminal “1”
and “2” on TB2 in the CH-Box.
5. For a CH-Box in the same refrigerant cycle, an electrical power supply can be supplied by one main
switch.
6. Do not connect the power supply line (220-240V/220V/230V) to the terminal block for transmission line.
7. Connect the ground wiring for the outdoor/indoor units and CH-Box. When ground resistance is less
than 100 ohms, ground wiring work should be performed by the qualified electrician.
8. Do not run the communication cables along with power supply wirings in the CH-Box.
Separate communication cables from the power supply wirings.

22 P5417025-rev.1

2-202 FAN-2209 201709


CH BOX

6.3 Electrical Wiring


The electrical wiring connection for the CH-Box is shown in Figure 6.1.
(1) Turn OFF the main power switch and take off the electrical box cover of CH-Box.
(2) Connect the power supply wiring to L1 and L2 on the terminal block TB1, and connect ground wiring to
the terminals in the electrical box.
(3) Connect the communication cable between the outdoor unit and CH-Box to TB2 of the CH-Box.
Connect the communication cable between the CH-Box and indoor unit to TB3 and TB4 of the
CH-Box.
Ensure that the communication cable between the CH-Box and indoor unit is connected to the same
letter as piping connection. (Tightening Torque: 1.0 to 1.3 N.m (0.7 to 1.0 ft.lbs))
Refer to “Example of Electrical Wiring” for the wiring connection.
(4) Tightly clamp the wires using the cable clamp inside the electrical box.
(5) Make sure the communication cables outside the electrical box does not touch sharp edges by
securing with clamp (accessory (7)).
(6) Attach the electrical box cover after completing the wiring work.

Terminal Blocks for Communication


Ground Terminal between CH-Box and Indoor Unit

Terminal Block
PCN1 PCN2 PCN1 PCN2 PCN1 PCN2

for Power Supply TB1 PCB1 PCB2 PCB3


LED10 LED10 LED10
CN1

CN1

CN1
LED11 LED11 LED11
LED2

LED2

LED2
LED12 LED12 LED12
LED1

LED1

LED1
LED13 LED13 LED13
CN2

CN2

CN2
LED14 LED14 LED14

LED15 LED4 LED5 LED6 LED7 LED15 LED4 LED5 LED6 LED7 LED15 LED4 LED5 LED6 LED7
CN3

CN3

CN3
TP DSW1 DSW2 DSW3 TP DSW1 DSW2 DSW3 TP DSW1 DSW2 DSW3
ON ON ON ON ON ON ON ON ON

LED16 1 2 3 4 5 6 1 2 3 4 1 2
LED16 1 2 3 4 5 6 1 2 3 4 1 2
LED16 1 2 3 4 5 6 1 2 3 4 1 2

TB2
CN11 CN11 CN11
LED17 LED17 LED17
LED3

LED3

LED3
Wire Clip
CN4

CN4

CN4
DSW5

DSW6

DSW7

DSW8

DSW5

DSW6

DSW7

DSW8

DSW5

DSW6

DSW7

DSW8
ON ON ON ON ON ON ON ON ON ON ON ON

1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2

(Use to
CN12 CN12 CN12
CN5

CN5

CN5
ON ON ON
DSW4

DSW4

DSW4
1 2 1 2 1 2

route wiring)
CN6

CN6

CN6
TB3 TB4 TB3 TB4 TB3 TB4
CN9 CN10 CN9 CN10 CN9 CN10

CN7 CN8 CN7 CN8 CN7 CN8

1 2 3 4 1 2 3 4 1 2 3 4

A B C D E F G H I J K L

Cable Clamp Cable Clamp Cable Clamp Cable Clamp

Clamp Clamp Clamp


(Accessory (7)) (Accessory (7)) (Accessory (7))
Communication Cable
Communication cable between
the outdoor unit and CH-Box.

Power Supply Wiring Connection Control Wiring Connection


(φ26mm [1 inch]) (3 x φ26mm [1 inch])

Screw Size Tightening Torque


TB1 Terminal Block for Power Supply Cable M4 1.0 ~ 1.3 N.m
TB2 Terminal Block for Communication Cable M3.5 0.7 ~ 0.9 N.m
TB3, TB4 Terminal Block for Communication Cable M4 1.0 ~ 1.3 N.m

Above figure illustrate the example of CH-AP12MSSX.


Number of PCBs are different depending on model number.
Refer to the following table.
PCB1 PCB2 PCB3 PCB4
CH-AP06MSSX
CH-AP08MSSX
CH-AP12MSSX
CH-AP16MSSX

NOTE:
The accessory numbers are listed in Table 4.1.
Figure 6.1 Electrical Wiring Connection

P5417025-rev.1 23

FAN-2209 201709 2-203


CH BOX

6.4 Setting of DIP Switches


DSWs on the PCB1 are set before shipping as shown below and no setting is required.

Connection Ports
for Indoor Unit
A B C D M N O P
Table 6.2 Cross reference table of DIP switch settings and connection ports for indoor unit.
CH-AP16MSSX
Models CH-AP12MSSX JCH-AP16MSSX
PCB1 PCB4
CH-AP04MSSX CH-AP08MSSX JCH-AP12MSSX
DSW1 DSW1
JCH-AP04MSSX JCH-AP08MSSX
DSW2 DSW2
DSW3 DSW3
Connection ports for indoor unit A B C D E F G H I J K L M N O P
DSW5 DSW6 DSW5 DSW6 PCB No. PCB1 PCB2 PCB3 PCB4
DSW4 DSW7 DSW4 DSW7 DSW2 Pin No. 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4
DSW8 DSW8 DSW5~8 DSW DSW DSW DSW DSW DSW DSW DSW DSW DSW DSW DSW DSW DSW DSW DSW
5 6 7 8 5 6 7 8 5 6 7 8 5 6 7 8
DSW4~8 Fuse Recover
In the case of applying high voltage to terminals of TB2, TB3 or TB4, the 0.5A
DSW1 DSW2 Connection Port Setting DSW3 fuse on the PCB is open. In such a case, first reconnect the wiring correctly
This setting is required. to the terminal block, and then set the No.1 pin to ON.
No setting is required. When the connection port is not used, turn ON No setting is required. DSW4 (for TB2) DSW5~8 (for TB3 and TB4)
the applicable pin shown in the table 6.2.
Factory Setting Fuse Recover Factory Setting Fuse Recover
ON ON (Example) ON
When connection port "D" is ON ON ON ON
123456 1234 not used, turn ON 12 12 12 12 12
DSW2-No.4 pin on PCB1.

NOTE
The “n” mark indicates the position of DIP switches. Figures show setting before shipment.

NOTICE
All indoor and outdoor units must be shut down prior to attempting to make DIP Switch adjustments,
otherwise, the settings will not take effect.

24 P5417025-rev.1

2-204 FAN-2209 201709


CH BOX

7. Test Run

NOTICE
Refrigerant piping and connecting wires should be connected to the same refrigerant cycle system.
If they are connected to the dissimilar refrigerant cycle systems, a malfunction may occur.

● Special Attention Regarding Refrigerant Gas Leakage


The refrigerant R410A is non-toxic and inflammable in its original state.
However, in consideration of a state where the refrigerant leaks into the room, measures against
refrigerant leaks must be taken in small rooms where the tolerable level could be exceeded.
Take countermeasures by installing ventilation devices,etc.
< Calculation of Refrigerant Concentration >
(1) Calculate the total quantity of refrigerant R (kg) charged in the system connecting all the indoor units
of rooms to be air-conditioned.
(2) Calculate the room Volume V (m3) of each room.
(3) Calculate the refrigerant concentration C (kg/m3) of the room according to the following equation.

R: Total Quantity of Charged Refrigerant (kg)


V: Room Volume (m3) = C: Refrigerant Concentration
< 0.42 (kg/m3) for R410A

250

Range below the


200 density
limit of 0.42kg/m3
Room Volume (m3)

(Countermeasures
Not Needed)
150

Range above the limit of


100 0.42kg/m3
(Countermeasures Needed)

50

0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150

Total Quantity Charged of Refrigerant (kg)

Perform a test run according to the “Installation and Maintenance Manual” of the outdoor unit.

● Do not operate the system until all the check points are cleared.
(A) Check to ensure that the electrical resistance is more than 1 megohm by measuring the
resistance between ground and the terminal block in the electrical box. If not, do not operate
the system until the electrical leakage is found and repaired.
(B) Check to ensure that the stop valves of the outdoor unit are fully opened, and then start the
system.
(C) Apply power to the outdoor unit(s) at least 12 hours prior to operation of the system for
preheating of the compressor oil.
● Pay attention to the following items while the system is running.
(A) Do not touch any of the parts by hand at the discharge gas side, since the compressor
chamber and the pipes at the discharge side are heated higher than 90°C (194°F).

P5417025-rev.1 25

FAN-2209 201709 2-205


CH BOX

Table 7.1 Alarm Code

Code Category Content of Abnormality Leading Cause


Incorrect Wiring, Loose Terminals, Disconnected
Abnormal Communication between
03 Communication Communication Cable, Blowout of Fuse, Indoor Unit Power
Indoor Units and Outdoor Units
OFF
2 or More CH-Boxes are Connected between
C1 Incorrect CH-Box Connection
Outdoor Unit and Indoor Unit
9 or More Indoor Units Connected to Single Branch Type CH-Box
C2 Incorrect Indoor Unit Connection Number 7 or More Indoor Units Connected per a Branch of Multiple
Branch Type CH-Box
CH-Box Incorrect Indoor Unit Refrigerant Number Indoor Units of Different Refrigerant Cycle Number are
C3
Setting Connected to CH-Box
Incorrect Connection between Ch-Box and
C4 This Outdoor Unit is not compatible with this CH-Box.
Outdoor Units
Indoor Unit is connected to a port that is set to not used for
C5 Incorrect Connection Port Setting
Multiple Branch Type CH-Box.

8. Safety and Control Device Setting


CH-Box
CH-AP04MSSX, CH-AP08MSSX,
CH-AP12MSSX, CH-AP16MSSX
Model
JCH-AP04MSSX, JCH-AP08MSSX,
JCH-AP12MSSX, JCH-AP16MSSX
For Control Circuit
Fuse A 5

26 P5417025-rev.1

2-206 FAN-2209 201709


© 2017 Johnson Controls, Inc. www.johnsoncontrols.com Form FAN-2209 201709