You are on page 1of 1

A B C D E F G H I J K

LEYENDA GENERAL:
AREA SIN INTERVENCIÓN

ESTRUCTURA EXISTENTE

1 TABIQUE EXISTENTE

TABIQUE DE DRYWALL NUEVO

10 9 8 7 6 5 SIMBOLOGIA:

#ELEV INDICADOR DE ELEVACIONES


32.80 #LAM INTERIORES
4.40 8.00 8.00 2.66 9.74

Nivel 4 #DET LLAMADO DE DETALLES


12.00

0.25
#LAM

0.81

0.81

0.81

0.81
FT−02 FT−02 FT−02
FT−01 L-01 L-01 L-01 L-01 L-01 L-01 L-01 L-01 L-01 L-01 L-01 L-01 L-01 FT−01
L-10a NOTA:

0.19

0.19
0.54
1. ES IMPORTANTE CONSIDERAR UNA MEDICION EN EL SITIO
DEBIDO A QUE EL EDIFICIO NO CUENTA CON UN
Coffee Reading LEVANTAMIENTO Y PLANOS AS BUILT.

4.00
3.75
Huddle Space Work Points Area 2. PERALTE DE VIGAS, ALTURA A FONDO DE LOSA Y
2 73pax

2.96
MAMPARAS DEL PERIMETRO EXISTENTE DEBEN SER
2.75

2.75

2.77
VERIFICADOS EN SITIO.

2.40
M−07b 3. LA ALTURA DE TODOS LOS TABIQUES NUEVOS EN EL
MRU−01 M−02 MRU−01 MRU−01 M−02 MRU−01 MRU−01 M−02 MRU−01 MRU−01 M−02 MRU−01 MRU−01 M−02 MRU−01 MRU−01 M−02 MRU−01 MRU−01 M−02 MRU−01 PROYECTO INICIAN EN PISO EXISTENTE Y TERMINA EN
LOSA SUPERIOR, ES DECIR DE PISO A TECHO. VER LÁMINA
M−17 M−17 M−17 M−17 M−17 M−17 M−17 M−17 M−17 M−17 M−17 M−17 M−17 M−17 ER−HW−DET−TAB−01.
OF 2401
8.00

0.25
FT−02
0.20 0.79

0.79

0.79

0.79
FT−02 FT−02 FT−02
FT−01 FT−01 FT−01
L-01 L-01 L-01 L-01 L-01 L-01 L-01 L-01 L-01 L-01 L-01 FT−04
FT−01

0.21

0.21
0.56

4.00
3.75
Manager Office WorkPoints
Huddle Space 64pax Tea Room
2.76

2.76

MRU−01 M−02 MRU−01 MRU−01 M−02 MRU−01 MRU−01 M−02 MRU−01 MRU−01 M−02 MRU−01 MRU−01 M−02 MRU−01 MRU−01 M−02 MRU−01 MRU−01 M−01 M−21
MRU−02 MRU−02 MO−11
3 M−17 M−17 M−17 M−17 M−17 M−17 M−17 M−17 M−17 M−17 M−17 M−17 M−17
OF 2301
4.00

0.25
0.97

1.00

1.00

1.00

1.00
FT−01 FT−02 FT−02 FT−02 FT−02 FT−01
L-10b L-10b

L-05 L-05

4.00
Work Points

3.75
Coffee Bar 69pax Manager Office
2.78

2.75

2.75

2.75

2.75

2.75
M−01 M−01 M−01

MRU−01 MRU−01 MRU−01 M−02 MRU−01 MRU−01 M−02 MRU−01 MRU−01 M−02 MRU−01 MRU−01 M−02 MRU−01 MRU−01 M−02 MRU−01 MRU−01 M−26a MRU−02MRU−02
MRU−02

0.73
0.76

0.72
M−17 M−17 M−17 M−17 M−17 M−17 M−17 M−17 M−17 M−17 M−17 M−17 M−17
OF 2201
0.00

4 Sección C
C 1 : 75

5 4 5 6 7 8 9 10 11
35.80

1.50 9.74 2.66 8.00 8.00 4.40 1.50


Nivel 4
12.00 Proyecto

0.25
FT−01 FT−01 Huawei Begonias
1.00

1.00

1.00
FT−02
FT−02

1.40
L-10aL-10a L-10a L-10a L-10a L-10a L-10a L-10a L-10a L-10a L-10a L-10a L-10a L-10a L-10a L-10a L-10a L-10a

0.35
L-04 L-04 Torre Begonias

0.00
Calle Las Begonias 415 − San Isidro.

4.00
Lima

3.75
Work Points Huddle Space
73pax PLANO FINAL PARA LICITACIÓN
2.75

Print
2.75

2.75

2.75
2.40
M−18 Título de plano
MRU−01 M−26a MRU−01 MRU−01 M−26a MRU−01 MRU−01 M−26a MRU−01 MRU−01 M−26a MRU−01 MRU−01 M−26a MRU−01 MRU−01 M−26a MRU−01 MRU−01 M−26a MRU−01 MRU−01 M−26a MRU−01
Estado reformado. Secciones
6 OF 2401
8.00 generales

0.25
0.80

0.80

0.95

FT−02
1.00

1.00

1.00
FT−01 FT−02 FT−02 FT−02
L-10a L-10a L-10a L-10a L-10a L-10a L-10a L-10a L-10a L-10a L-10a L-10b Fecha 26/10/2022

0.35

0.35
L-04 Escala 1 : 75 Formato A−1
0.19

Cod. N° ER−HW−SEC−20

4.00
L-02

3.75
Work Points Work Points
Print
16pax 58pax Small Meeting
2.95

Director LA Dibujado GC
2.80
2.76

2.76

2.75

2.75

2.75
Room 4pax

2.40
Diseño XC Control LC

2.22
MO−18
M−04
MRU−01 MRU−01 M−01 MRU−01 MRU−01 M−01 MRU−01 M−26a MRU−01 MRU−01 M−26a MRU−01 MRU−01 M−26a MRU−01 MRU−01 M−26a MRU−01 MRU−01 M−26a MRU−01 MRU−01 M−26a MRU−01 MRU−02 MRU−02 Fecha de Revisión:
0.78

M−17 M−17 M−17 M−17


OF 2301
4.00

0.25
0.90
0.97

FT−02
FT−01 L-10a
7
0.38

0.15
0.68

Cliente Arquitecto

4.00
3.75
Work Points Huawei Luis Arce García
44pax CAP 15483
2.78

2.78

2.75

2.75
2.40

2.10

M−02
MRU−01 M−02
MRU−01 M−02
MRU−01 M−02
MRU−01 M−02
MRU−01 M−26a
3g office
M−17 M−17 M−17 M−17 M−17
OF 2201 Eloy Gonzalo, 18 Alberto del Campo 409 Of. 503
0.00 28010 Madrid Magdalena del Mar−15076 Lima
Teléfono 91 296 06 00 Teléfono (+51) 399 6331
Fax 91 296 06 99
Sección D www.3g−office.com larce@3g−office.com
D 1 : 75
Los diseños gráficos, las imágenes, los planos, las fotografías, los textos, así
como la información y los contenidos que se recogen en el presente
documento están protegidos por la legislación peruana sobre los derechos de
propiedad intelectual e industrial a favor de 3g office Perú S.A.C. y no se
permite su reproducción y/o publicación, total o parcial, ni su
8 tratamiento informático, su distribución, su difusión, ni su modificación,
transformación, ni demás derechos reconocidos legalmente a su titular, sin el
permiso previo y por escrito del mismo, 3g office Perú S.A.C. Cada
documento o plano puede detallar una disciplina particular por lo que
deberá ser siempre considerado dentro del conjunto de la documentación
completa, verificando su adecuada coordinación con ésta. Asimismo el
contratista responsable deberá cotejar siempre en obra las dimensiones y
especificaciones reales de cualquier elemento con el que pudiese interferir
lo expresado en el proyecto. En el supuesto de discrepancias entre
documentos, se instará a lo que resuelva la Dirección facultativa. Las
posibles omisiones, o incoherencias detectadas entre la distinta
documentación, deberán ser motivo de inmediata consulta a la Dirección
Facultativa; de lo contrario se entenderá que la documentación aportada se
comprende y resulta suficiente para el fin al que se destina.