You are on page 1of 32

Euro Trade Price List 2023

(version 2)

Ventilation Control Products Sweden AB

Sensors, Transmitters, Switches, Detectors, Thermostats, Valves & Actuators


for Building Management Systems (BMS) and HVAC

Established 2004 - world wide deliveries to more than 75 countries

Ventilation Control Products Sweden AB • +46-31-811666 • info@vcp.se • www.vcp.se


Index by product groups and pages 2023

Product group _Page

Particle Matter
PM1.0, PM2.5, PM4.0 and PM10 3

Air Velocity 4

Carbon Monoxide (CO) 5

Pressure 6-10

Humidity 11-13

Air Quality (VOC) 14

Carbon Dioxide (CO2 ) 15-17

Temperature 18-19

Sensor Shields /
Sensor Guards 20

Water Detection 21-22

Smoke 23

Light Level 24

Flow 24

Thermostats 25

Zone Valves and


Actuators 26-27

Damper Actuators 28-30

General information 31

Shippings 32

Ventilation Control Products Sweden AB • +46-31-811666 • info@vcp.se • www.vcp.se


Room Particle Matter transmitter 2023

Features
• Particle size measurements
PM1.0, PM2.5, PM4.0 and PM10

• Concentration ranges
0 to 100 μg/m3 and 0 to 500 μg/m3

• Accuracy
10 μg/m3 for PM1.0 and PM2.5
25 μg/m3 for PM4.0 and PM10

• Maintenance-free,
fully factory calibrated laser optic sensor

• Estimated lifetime more than 10 years

PMR 51 MDR2B • Outputs


4-20 mA and 0-10 Vdc
• PM outputs 4-20 mA and 0-10 Vdc On request: 2-10 Vdc, 0-5 Vdc or 1-5 Vdc
• Modbus RS485 communication
• LCD Display • Power supply 24 Vac/dc
• 2 x relay outputs
• Buzzer

Temperature and Humidity Options

• See below type PMR C1T1H1 MDR2B

PMR 51

• PM outputs 4-20 mA and 0-10 Vdc

_______________________________________________________________________________________________________________
Type no. Description EURO
price
_______________________________________________________________________________________________________________

PMR 51 Room Particle Matter transmitter,


Two PM outputs, Output 1: 4-20 mA and Output 2: 0-10 Vdc ......................................................... 198.00

PMR 51 M Room Particle Matter transmitter,


Two PM outputs, Output 1: 4-20 mA and Output 2: 0-10 Vdc
Modbus RS485 communication …………………………………........................................................ 208.00

PMR 51 MDR2B Room Particle Matter transmitter,


Two PM outputs, Output 1: 4-20 mA and Output 2: 0-10 Vdc
Modbus RS485 communication, LCD Display, 2 x relay outputs and Buzzer ………....................... 250.00

PMR P1T1H1 MDR2B Room Particle Matter, Temperature and Humidity transmitter
PM output 0-10 Vdc
TEMP. output 0-10 Vdc
HUM. output 0-10 Vdc
Modbus RS485 communication, LCD Display, 2 x relay outputs and Buzzer ………........................ 280.00

Other PMR types in data sheet.

Ventilation Control Products Sweden AB • +46-31-811666 • info@vcp.se • www.vcp.se 3


Air Velocity Transmitters 2023

Features

• Ranges

AVT 251 and AVT 251 MDR 2B:


0-5 m/s, 0-10 m/s, 0-15 m/s or 0-20 m/s
DIP switches selectable

AVT 551 and AVT 551 MDR2B:


0-1 m/s, 0-2 m/s, 0-3 m/s or 0-5 m/s
DIP switches selectable

• Two outputs for Air Velocity


4-20 mA and 0-10 Vdc as standard
2-10 Vdc, 0-5 Vdc and 1-5 Vdc on request
AVT 251
AVT 251 • Accuracy Air Velocity

± 5 % for 0-20 m/s

• Response time 1 second or 5 seconds


DIP switches selectable

• Power supply 24 Vac/dc

• IP ratings
IP65 for enclosure
IP10 for probe

• Duct mounting flange with neoprene gasket


for good sealing into the duct and for
adjust the penetration probe depth

AVT 251 MDR2B and AVT 551 MDR2B with:

• Modbus RS485 communication


AVT 251 MDR2B
• LCD Display

• 2 x relay outputs

• Buzzer
_______________________________________________________________________________________________________________
Type no. Description EURO
price
_______________________________________________________________________________________________________________

AVT 251 Air Velocity transmitter


Ranges 0-5 m/s, 0-10 m/s, 0-15 m/s or 0-20 m/s, DIP switches selectable
Output 1 (AO1) : 4-20 mA, Output 2 (AO2) : 0-10 Vdc ...................................................................... 158.00

AVT 551 Air Velocity transmitter


Ranges 0-1 m/s, 0-2 m/s, 0-3 m/s or 0-5 m/s, DIP switches selectable
Output 1 (AO1) : 4-20 mA, Output 2 (AO2) : 0-10 Vdc ...................................................................... 158.00

AVT 251 MDR2B Air Velocity transmitter


Ranges 0-5 m/s, 0-10 m/s, 0-15 m/s or 0-20 m/s, DIP switches selectable
Output 1 (AO1) : 4-20 mA, Output 2 (AO2) : 0-10 Vdc
Modbus RS485 communication, LCD Display , 2 x Relay outputs and Buzzer ………........................ 210.00

AVT 551 MDR2B Air Velocity transmitter


Ranges 0-1 m/s, 0-2 m/s, 0-3 m/s or 0-5 m/s, DIP switches selectable
Output 1 (AO1) : 4-20 mA, Output 2 (AO2) : 0-10 Vdc
Modbus RS485 communication, LCD Display , 2 x Relay outputs and Buzzer ………........................ 210.00

Other AVT types in data sheet.

On request output number 2 (AO2) can be supplied as Temperature output instead of Air Velocity output.

Ventilation Control Products Sweden AB • +46-31-811666 • info@vcp.se • www.vcp.se 4


Carbon Monoxide (CO) Detectors
2023

Features

COW 1351 and COW 1351 MDR2B:

• Replaceable Electrochemical Cell (sensor)

• Measuring ranges
0-50 ppm, 0-100 ppm, 0-200 ppm or 0-300 ppm,
selectable ranges with DIP switch
on request 0-500 ppm and 0-1000 ppm

Price 134 Euro • Two Analogue Outputs


Output 1 : 4-20 mA
Output 2 : 0-10 Vdc

COW 1351 • Response time


1 sec, 5 sec, 30 sec or 60 sec,
selectable with DIP switch

• Zero-Span Calibration & Linear output

• Power supply 24 Vac/dc

• IP ratings
IP65 for enclosure
IP41 for probe

• Accuracy ±3 %

• t90 < 50 sec.


Price 186 Euro
• Sensor life time 6 years expected

More (extra) features for COW 1351 MDR2B:

COW 1351 MDR2B • Modbus RS485 communication

• LCD Display

• 2 x relay outputs, user can set any level


COW 1351 and COW 1351 MDR2B are standard types,
Other COW types in data sheet • Buzzer

Other gas detectors on request such:

• Nitrogen Dioxide (NO2) Gas Detectors

• Nitrogen Monoxide – Nitric Oxide (NO) detectors

• Ammonia (NH3) Gas Detectors

• Oxygen (O2) Gas Detectors

• Ozone (O3) Gas Detectors

• Hydrogen Sulfide (H2S) Gas Detectors

• Chlorine (CI2) Gas Detectors

• Methane (CH4) Gas Detectors

Ventilation Control Products Sweden AB • +46-31-811666 • info@vcp.se • www.vcp.se 6


Air Pressure Transmitters
4 to 8 selectable pressure ranges,
2 selectable outputs 0-10 Vdc or 4-20 mA in same unit 2023

Features

• 4 to 8 pressure ranges in same unit,


pressure range selectable via DIP-switches on pcb.

Pressure ranges for PAM 10VC and PAM 10VC D


0 to 50 Pa / -50 to +50 Pa
0 to 100 Pa / -100 to +100 Pa

Pressure ranges for PAM 11VC and PAM 11VC D


0 to 100 Pa / -100 to +100 Pa
0 to 300 Pa / -300 to +300 Pa
0 to 500 Pa / -500 to +500 Pa
0 to 1000 Pa / -1000 to +1000 Pa

• Selectable output 0-10 Vdc or 4-20 mA (3-wire)

• Accuracy
PAM 11VC without LCD display PAM 10VC and PAM 10VC D (100 Pa) +/-3 Pa at 25 °C
PAM 11VC and PAM 11VC D (1000 Pa) +/-10 Pa at 25 °C

• Power supply 24 Vac/dc

• IP67 protection

• With or without LCD display

• Push button for manual zero point calibration


and an adjustable offset.

• Including duct fixing kit


(2 plastic tubes with integrated mounting plate,
2 meters PVC hose and 4 screws)

PAM 11VC D with LCD display

_______________________________________________________________________________________________________________
Type no. Description EURO
price
_______________________________________________________________________________________________________________

Air Pressure Transmitter, selectable output 0-10 Vdc or 4-20 mA

PAM 10VC 0 to 50 Pa / -50 to +50 Pa


0 to 100 Pa / -100 to +100 Pa ………………………………………………………............................... 107.00

PAM 10VC D same as PAM 10VC and with LCD display ………………………….………………............................ 134.00

PAM 11VC 0 to 100 Pa / -100 to +100 Pa


0 to 300 Pa / -300 to +300 Pa
0 to 500 Pa / -500 to +500 Pa
0 to 1000 Pa / -1000 to +1000 Pa ……………………………………………………….......................... 107.00

PAM 11VC D same as PAM 11VC and with LCD display………………………….………………............................... 134.00
____________________________________________________________________________________________________________

On request: Air Pressure Transmitters PAM 15VC and PAM 15VC D with pressure ranges
0 to 1000 Pa / -1000 to +1000 Pa, 0 to 2000 Pa / -2000 to +2000 Pa
0 to 3000 Pa / -3000 to +3000 Pa, 0 to 5000 Pa / -5000 to +5000 Pa

Ventilation Control Products Sweden AB • +46-31-811666 • info@vcp.se • www.vcp.se 6


Air Differential PressureTransmitters
Flexible & Multi Functional 2023

Features
• High accuracy +/-1%

• Power Supply and Output


16-30 Vac/dc with 0-10 Vdc (3-wire) for PAT 010D
12-30 Vdc with 4-20 mA (2-wire) for PAT 420D

• LCD digital display

• Including duct fixing kit


2 plastic tubes with integrated mounting plate,
2 metres PVC hose and
4 screws

• Including mounting bracket

PAT 010D • IP54 protection

Pressure ranges
DIP-switches on PCB to select
10 pressure ranges in same unit selectable
Pressure Range, via DIP-switches on pcb.

Pressure Unit and Full range:


0 to 100 Pa, 0 to 250 Pa, 0 to 500 Pa,
Response Time 0 to 750 Pa or 0 to 1000 Pa

Bi-directional:
-50 to +50 Pa , -125 to 125 Pa, -250 to +250 Pa,
-375 to +375 Pa or -500 to +500 Pa

Pressure Units

Other pressure units than Pa are available and


selectable via DIP switches on pcb
mmHH2O, mbar, inWG, mmHG, daPa, Kpa, hPa

Response Times

Response time selectable via DIP switches on pcb


0.5 ,1.0, 2.0 or 4.0 seconds

___________________________________________________________________________________________________________
Type no. Description EURO
price
____________________________________________________________________________________________________________

PAT 010D Air Differential PressureTransmitter , Flexible & Multi Functional 0-10 Vdc output .............................. 156.00

PAT 420D Air Differential PressureTransmitter , Flexible & Multi Functional 4-20 mA output ...............................156.00

____________________________________________________________________________________________________________

On request: Air Differential PressureTransmitter with display and higher pressure ranges than 0-1000 Pa (984M.5xx114-series)

http://www.ventilationcontrolproducts.net/air-differential-pressure-transmitters

Ventilation Control Products Sweden AB • +46-31-811666 • info@vcp.se • www.vcp.se 7


Air Differential PressureTransmitters
with 0-10 Vdc or 4-20 mA output 2023

Features
• Selectable output via jumper
0-10 Vdc or 4-20 mA output, 3-wire
with power supply 24 Vac/dc

• 4-20 mA output, 2-wire


with power supply 24 Vdc

• Pressure ranges
from 0-100 Pa up to 0-250 kPa
Customized pressure ranges on request

• 2 adjoining pressure ranges in one unit,


pressure ranges selectable via jumper

• With out display as standard

• Including duct fixing kit


984M.533104
2 plastic tubes with integrated mounting plate,
2 metres PVC hose and
4 screws

__________________________________________________________________________________________________________________
Type no. Analogue Analogue Pressure Pressure EURO
output 1 output 2 range 1 range 2 price
__________________________________________________________________________________________________________________

Air Differential PressureTransmitter, power supply 24 Vac/dc, 3-wire connection and switch output

984M.523104 0-10 Vdc 4-20 mA 0 to 100 Pa 0 to 250 Pa ……………………………. 122.00


984M.533104 0-10 Vdc 4-20 mA 0 to 250 Pa 0 to 500 Pa ……………………………. 122.00
984M.543104 0-10 Vdc 4-20 mA 0 to 500 Pa 0 to 1.000 Pa ……….…………………. 122.00
984M.553104 0-10 Vdc 4-20 mA 0 to 1 kPa 0 to 2.5 kPa ……………………………. 122.00
984M.573104 0-10 Vdc 4-20 mA 0 to 5 kPa 0 to 10 kPa ……………………………. 122.00
984M.593104 0-10 Vdc 4-20 mA 0 to 25 kPa 0 to 50 kPa ……………………………. 122.00
984M.5B3104 0-10 Vdc 4-20 mA 0 to 100 kPa 0 to 250 kPa ……………………………. 122.00
____________________________________________________________________________________________________________

Air Differential PressureTransmitter, power supply 24 Vac/dc, 3-wire connection and switch output and LED display

984M.523114 0-10 Vdc 4-20 mA 0 to 100 Pa 0 to 250 Pa …………………………… 166.00


984M.533114 0-10 Vdc 4-20 mA 0 to 250 Pa 0 to 500 Pa …………………………… 166.00
984M.543114 0-10 Vdc 4-20 mA 0 to 500 Pa 0 to 1.000 Pa …………………………. 166.00
984M.553114 0-10 Vdc 4-20 mA 0 to 1 kPa 0 to 2.5 kPa …………………………… 166.00
984M.573114 0-10 Vdc 4-20 mA 0 to 5 kPa 0 to 10 kPa ……………………………. 166.00
984M.593114 0-10 Vdc 4-20 mA 0 to 25 kPa 0 to 50 kPa ……………………………. 166.00
984M.5B3114 0-10 Vdc 4-20 mA 0 to 100 kPa 0 to 250 kPa ……………………………. 166.00
____________________________________________________________________________________________________________

Air Differential PressureTransmitter, power supply 24 Vdc, 2-wire connection

984M.523204 4-20 mA 0 to 100 Pa 0 to 250 Pa ……………………………. 122.00


984M.533204 4-20 mA 0 to 250 Pa 0 to 500 Pa ……………………………. 122.00
984M.543204 4-20 mA 0 to 500 Pa 0 to 1.000 Pa ……….…………………. 122.00
984M.553204 4-20 mA 0 to 1 kPa 0 to 2.5 kPa ……………………………. 122.00
984M.573204 4-20 mA 0 to 5 kPa 0 to 10 kPa ……………………………. 122.00
984M.593204 4-20 mA 0 to 25 kPa 0 to 50 kPa ……………………………. 122.00
984M.5B3204 4-20 mA 0 to 100 kPa 0 to 250 kPa ……………………………. 122.00
____________________________________________________________________________________________________________

On request: customized pressure ranges -50 Pa to +50 Pa, -100 Pa to +100 Pa, -500 Pa to +500 Pa, 0 to -50 kPa etc.

Ventilation Control Products Sweden AB • +46-31-811666 • info@vcp.se • www.vcp.se 8


Differential PressureTransmitter PTO 500V
Liquid Static Pressure Transmitters PLTS
2023

Differential PressureTransmitter PTO 500V


• Output 0-10 Vdc

• Pressure range 0 to 500 Pa

• IP54 protection
Price PTO 500V
• Small size, diameter 66 mm, height 28 mm
84.00 Euro
• Response time, selectable 0.1 to 1.0 sec.

PTO 500V • Easy offset calibration

Duct Fixing Kit DFK 200

• To be ordered separately

• DFK 200 includes


2 plastic tubes with integrated mounting plate,
Price DFK 200 2 metres PVC hose and
4 screws
2.10 Euro
Other outputs and other pressure ranges on request
• 4-20 mA (2-wire), 4-20 mA (3-wire)

DFK 200 • 0 to 100 Pa, 0 to 250 Pa, 0 to 1 kPa , 0 to 2.5 kPa


0 to 10 kPa, 0 to 25 kPa, 0 to 50 kPa, 0 to 100 kPa

• Other PTO types than PTO 500V


supplied in 60-packs.

Liquid Static Pressure Transmitter PLTS

• 0-10 Vdc output (3-wire) and


4-20 mA output (2-wire)

• Pressure range 0 to 10 Bar,


other ranges on request

• G1/4” connection thread and


G1/2” connection thread

• Power supply
12-30 Vac/dc for 0-10 Vdc output
12-30 Vdc for 4-20 mA output.
PLTS 010 10 G12
• Protection class IP65

_________________________________________________________________________________________________________________
Type no. Output Pressure Connection EURO
range thread price
_________________________________________________________________________________________________________________

PLTS 010 10 G14 0-10 Vdc 0 to 10 Bar G1/4” …………………………………………………………. 110.00

PLTS 010 10 G12 0-10 Vdc 0 to 10 Bar G1/2” …………………………………………………………. 110.00

PLTS 420 10 G14 4-20 mA 0 to 10 Bar G1/4” …………………………………………………………. 110.00

PLTS 420 10 G12 4-20 mA 0 to 10 Bar G1/2” …………………………………………………………. 110.00

Ventilation Control Products Sweden AB • +46-31-811666 • info@vcp.se • www.vcp.se 9


Air Differential Pressure Switches
with on/off Output 2023

Features

• On/off output

• Electrical rating 250 Vac

• 7 different pressure ranges


from 20-200 Pa up to 1.000-4.000 Pa

• Switching pressure can easily be


adjusted on a scaled adjustment knob

• Static, over, differential pressure and vaccum

930.83 222511 • IP54 protection (IP65 on request)

Can be deliveried in 3 different alternatives

1. Only the pressure switch

2. The pressure switch separately packed


and the duct fixing kit separately packed.

3. The pressure switch and the duct fixing kit


packed together in one carton.

DFK 200

__________________________________________________________________________________________________________________
Type no. Adjustment Switching Output Electrical EURO
pressure range differential rating price
__________________________________________________________________________________________________________________

Air Differential Pressure Switch

930.80 222511 20–200 Pa 10 Pa on/off 250 Vac 20.00


930.80 222511N 20–300 Pa 10 Pa on/off 250 Vac 20.00
930.84 222511 30– 400 Pa 15 Pa on/off 250 Vac 20.00
930.83 222511 50– 500 Pa 20 Pa on/off 250 Vac 20.00
930.85 222511 200–1.000 Pa 100 Pa on/off 250 Vac 20.00
930.86 222511 500–2.500 Pa 150 Pa on/off 250 Vac 20.00
930.87 222511 1000–4.000 Pa 250 Pa on/off 250 Vac 20.00
_________________________________________________________________________________________________________________

DFK 200 Duct fixing kit includes


2 plastic tubes with integrated mounting plate,
2 metres PVC hose and
4 screws ............................................................................................. 2.10
________________________________________________________________________________________________________________

Air Differential Pressure Switch


with duct fixing kit (DFK 200), packed together into a carton.

930.80 222534 20–200 Pa 10 Pa on/off 250 Vac 24.00


930.80 222534N 20–300 Pa 10 Pa on/off 250 Vac 24.00
930.84 222534 30– 400 Pa 15 Pa on/off 250 Vac 24.00
930.83 222534 50– 500 Pa 20 Pa on/off 250 Vac 24.00
930.85 222534 200–1.000 Pa 100 Pa on/off 250 Vac 24.00
930.86 222534 500–2.500 Pa 150 Pa on/off 250 Vac 24.00
930.87 222534 1000–4.000 Pa 250 Pa on/off 250 Vac 24.00
________________________________________________________________________________________________________________

On request: Air Differential Pressure Switch with other pressure ranges than above.

Ventilation Control Products Sweden AB • +46-31-811666 • info@vcp.se • www.vcp.se 10


Humidity & Temperature Transmitters
For Rooom Mounting 2023

Features

• Humidity and Temperature outputs in same unit

• Humidity output 0-10 Vdc or 4-20 mA

• Temperature output 0-10 Vdc or 4-20 mA

• Passive temperature sensing element


PT1000, PT100, NTC 10K, NTC 20K, NTC 1.8K , NI1000
etc as option

• With or without display

• Humidity accuracy ± 2% at 20 to 80% rH

RHT 010 010 D with LCD display • Temperature accuracy 0,3K (+5°C to 60°C) + 1.5% f.s

• 4 selectable temperature ranges via DIP switches

• DIP switch on pcb to select:


- Relative Humidity,
- Absolute Humidity
- Dew Point or
- Enthalpy

Colored LCD display

RHT 010 010 with out LCD display

_________________________________________________________________________________________________________________
Type no. Humidity Temp. Passive temp. LCD EURO
output output sensing element Display price
__________________________________________________________________________________________________________________

RHT 010 010 0-10 Vdc 0-10 Vdc No No ....................... 118.00

RHT 010 010 D 0-10 Vdc 0-10 Vdc No Yes ...................... 158.00

RHT 420 420 4-20 mA 4-20 mA No No ....................... 118.00

RHT 420 420 D 4-20 mA 4-20 mA No Yes ...................... 158.00

RHT 010 010 XXX 0-10 Vdc 0-10 Vdc Yes No ........................ 128.00

RHT 010 010 XXX D 0-10 Vdc 0-10 Vdc Yes Yes ...................... 168.00

RHT 420 420 XXX 4-20 mA 4-20 mA Yes No ........................ 128.00

RHT 420 420 XXX D 4-20 mA 4-20 mA Yes Yes ...................... 168.00

XXX = passive temperature sensing element


PT100, PT100 1/3 DIN, PT1000, PT1000 1/3 DIN, NI1000, NI1000/TK5000, NTC 1.8K, NTC 5K, NTC 10K, NTC 20K, KTY81-210

Example:
Humidity output 0-10 Vdc, Temperature Output 0-10 Vdc PT1000 passive temperature sensing element and display,
type is : RHT 010 010 PT1000 D

Ventilation Control Products Sweden AB • +46-31-811666 • info@vcp.se • www.vcp.se 11


Humidity & Temperature Transmitters
For Duct Mounting 2023

Features

• Humidity and Temperature outputs in same unit

• Humidity output 0-10 Vdc or 4-20 mA

• Temperature output 0-10 Vdc or 4-20 mA

• Passive temperature sensing element


PT1000, PT100, NTC 10K, NTC 20K, NTC 1.8K , NI1000
etc as option

• With or without LCD display

• Humidity accuracy ± 2% at 20 to 80% rH

DHT 010 010 D with LCD display • Temperature accuracy 0,5K

• 4 selectable temperature ranges via DIP switches

• DIP switch on pcb to select:


- Relative Humidity,
- Absolute Humidity
- Dew Point or
- Enthalpy

• Including duct mounting flange

• IP65 protection

DHT 010 010 with out LCD display Colored LCD display

_________________________________________________________________________________________________________________
Type no. Humidity Temp. Passive temp. LCD EURO
output output sensing element Display price
__________________________________________________________________________________________________________________

DHT 010 010 0-10 Vdc 0-10 Vdc No No ....................... 138.00

DHT 010 010 D 0-10 Vdc 0-10 Vdc No Yes ...................... 178.00

DHT 420 420 4-20 mA 4-20 mA No No ....................... 138.00

DHT 420 420 D 4-20 mA 4-20 mA No Yes ...................... 178.00

DHT 010 010 XXX 0-10 Vdc 0-10 Vdc Yes No ........................ 148.00

DHT 010 010 XXX D 0-10 Vdc 0-10 Vdc Yes Yes ...................... 188.00

DHT 420 420 XXX 4-20 mA 4-20 mA Yes No ........................ 148.00

DHT 420 420 XXX D 4-20 mA 4-20 mA Yes Yes ...................... 188.00

XXX = passive temperature sensing element


PT100, PT100 1/3 DIN, PT1000, PT1000 1/3 DIN, NI1000, NI1000/TK5000, NTC 1.8K, NTC 5K, NTC 10K, NTC 20K, KTY81-210

Example:
Humidity output 0-10 Vdc, Temperature Output 0-10 Vdc PT1000 passive temperature sensing element and display,
type is : DHT 010 010 PT1000 D

Ventilation Control Products Sweden AB • +46-31-811666 • info@vcp.se • www.vcp.se 12


Humidity & Temperature Transmitters
For Duct Mounting 2023

Features

• Humidity and Temperature outputs in same unit

• Humidity output 0-10 Vdc or 4-20 mA

• Temperature output 0-10 Vdc or 4-20 mA

• Passive temperature sensing element


PT1000, PT100, NTC 10K, NTC 20K, NTC 1.8K , NI1000
etc as option

• With or without display

• Humidity accuracy ± 2% at 20 to 80% rH

OHT 010 010 D with LCD display • Temperature accuracy 0,3K (+5°C to 60°C) + 1.5% f.s

• 4 selectable temperature ranges via DIP switches

• DIP switch on pcb to select:


- Relative Humidity,
- Absolute Humidity
- Dew Point or
- Enthalpy
• IP65 protection

Colored LCD display

OHT 010 010 with out LCD display

_________________________________________________________________________________________________________________
Type no. Humidity Temp. Passive temp. LCD EURO
output output sensing element Display price
__________________________________________________________________________________________________________________

OHT 010 010 0-10 Vdc 0-10 Vdc No No ....................... 138.00

OHT 010 010 D 0-10 Vdc 0-10 Vdc No Yes ...................... 178.00

OHT 420 420 4-20 mA 4-20 mA No No ....................... 138.00

OHT 420 420 D 4-20 mA 4-20 mA No Yes ...................... 178.00

OHT 010 010 XXX 0-10 Vdc 0-10 Vdc Yes No ........................ 148.00

OHT 010 010 XXX D 0-10 Vdc 0-10 Vdc Yes Yes ...................... 188.00

OHT 420 420 XXX 4-20 mA 4-20 mA Yes No ........................ 148.00

OHT 420 420 XXX D 4-20 mA 4-20 mA Yes Yes ...................... 188.00

XXX = passive temperature sensing element


PT100, PT100 1/3 DIN, PT1000, PT1000 1/3 DIN, NI1000, NI1000/TK5000, NTC 1.8K, NTC 5K, NTC 10K, NTC 20K, KTY81-210

Example:
Humidity output 0-10 Vdc, Temperature Output 0-10 Vdc PT1000 passive temperature sensing element and display,
type is : OHT 010 010 PT1000 D

Ventilation Control Products Sweden AB • +46-31-811666 • info@vcp.se • www.vcp.se 13


Air Quality (VOC) transmitters
for Room and Duct Mounting 2023

VOCR 51 MDR2B (room) and VOCD 51 MDR2B (duct) VOCR 51 (room) and VOCD 51 (duct)

• VOC outputs 4-20 mA and 0-10 Vdc • VOC outputs 4-20 mA and 0-10 Vdc
• Modbus RS485 communication
• LCD Display
• 2 x relay outputs
• Buzzer

__________________________________________________________________________________________________________________
Type no. Description EURO
price
__________________________________________________________________________________________________________________

VOCR 51 Air Quality (VOC) transmitter for room mounting


VOC output 1: 4-20 mA, VOC output 2: 0-10 Vdc .......................................................................... 118.00

VOCR 51 M Air Quality (VOC) transmitter for room mounting


VOC output 1: 4-20 mA VOC output 2: 0-10 Vdc
Modbus RS485 communication ........................................................................................................ 128.00

VOCR 51 MDR2B Air Quality (VOC) transmitter for room mounting


VOC output 1: 4-20 mA, VOC output 2: 0-10 Vdc
Modbus RS485 communication, LCD Display, 2 x relay outputs and Buzzer .................................. 170.00
__________________________________________________________________________________________________________________

VOCD 51 Air Quality (VOC) transmitter for duct mounting


VOC output 1: 4-20 mA, VOC output 2: 0-10 Vdc .......................................................................... 150.00

VOCD 51 M Air Quality (VOC) transmitter for duct mounting


VOC output 1: 4-20 mA VOC output 2: 0-10 Vdc
Modbus RS485 communication ........................................................................................................ 160.00

VOCD 51 MDR2B Air Quality (VOC) transmitter for duct mounting


VOC output 1: 4-20 mA, VOC output 2: 0-10 Vdc
Modbus RS485 communication, LCD Display, 2 x relay outputs and Buzzer .................................. 202.00

Ventilation Control Products Sweden AB • +46-31-811666 • info@vcp.se • www.vcp.se 14


Carbon Dioxide (CO2) room transmitters
with Humidity and Temperature Options
2023

Features
• Maintenance free NDIR sensor

• Measuring ranges
400-2.000 ppm
0-2.000 ppm
0-5.000 ppm
0-10.000 ppm
selectable ranges with DIP switch
On request 0-1.000 ppm

• Estimated operating life 15 years

• ABC – Automatic Baseline Calculation

• Accuracy 70 ppm +3 % reading


CO2R 51 MDR2B

• CO2 outputs 0-10 Vdc and 4-20 mA


• Modbus RS485 communication
Temperature and Humidity Options
• LCD Display
• 2 x relay outputs
• See below type CO2R C1T1H1 MDR2B
• Buzzer

Other CO2R types

• See data sheet for wide range of different combinations

CO2R 51 M

• CO2 outputs 0-10 Vdc and 4-20 mA


• Modbus RS485 communication

__________________________________________________________________________________________________________________
Type no. Description EURO
price
__________________________________________________________________________________________________________________

CO2R 51 Carbon Dioxide (CO2) transmitter for room mounting


Two CO2 outputs, Output 1: 4-20 mA and Output 2: 0-10 Vdc ................................................. 178.00

CO2R 51 M Carbon Dioxide (CO2) transmitter for room mounting


Two CO2 outputs, Output 1: 4-20 mA and Output 2: 0-10 Vdc
Modbus RS485 communication ..................................................................................................... 188.00

CO2R 51 MDR2B Carbon Dioxide (CO2) transmitter for room mounting


Two CO2 outputs, Output 1: 4-20 mA and Output 2: 0-10 Vdc
Modbus RS485 communication, LCD Display, 2 x relay outputs and Buzzer ................................. 230.00

CO2R C1T1H1 MDR2B Carbon Dioxide (CO2) transmitter for room mounting
with Temperature and Humidity options,
CO2 output 0-10 Vdc
TEMP. output 0-10 Vdc
HUM. output 0-10 Vdc
Modbus RS485 communication, LCD Display, 2 x relay outputs and Buzzer ................................. 260.00

Ventilation Control Products Sweden AB • +46-31-811666 • info@vcp.se • www.vcp.se 15


Carbon Dioxide (CO2 ) Transmitters
for Room and Duct Mounting 2023

Features

• Carbon Dioxide (CO2 )


transmitters for room mounting

• CO2 measuring range 0-2.000 ppm

• CO2 output 0-10 Vdc

• CO2 accuracy +/-30 ppm plus 3% of measured value

• Enclosure material ABS Plastic


On request: Stainless steel

CDR 010N • Temperature measuring range 0 to +50°C (CDR 010T)

• Temperature output 0-10 Vdc (CDR 010T)

• Deviation temperature +/- 0.2 K at 25°C (CDR 010T)


__________________________________________________________________________________________________________________
Type no. Description EURO
price
__________________________________________________________________________________________________________________

CDR 010N Room CO2 transmitter 0-10 Vdc, 0-2000 ppm ............................................................................ 170.00

CDR 010T Room CO2 + Temperature transmitter 2 x 0-10 Vdc, 0-2000 ppm ................................................. 196.00

Features

• Carbon Dioxide (CO2 ) transmitters for duct mounting

• CO2 range 0-2000 ppm or 0-5000 ppm, jumper selectable

• Accuracy ± 30 ppm ± 3% of measured value

• Output 0-10 Vdc or 4-20 mA, jumper selectable

• Change over contact

• Optical NDIR sensor


CDK 24 (non-dispersive Infra-red technology)

• Self Calibrating

• Including duct mounting flange

• IP65 enclosure with quick locking screws

• CDK 24 with out display and CDK 24D with display

CDK 24D

__________________________________________________________________________________________________________________
Type no. Description EURO
price
__________________________________________________________________________________________________________________

CDK 24 Duct CO2 transmitter 0-10 Vdc or 4-20 mA, 0-2000 ppm or 0-5000 ppm, change over contact ....... 206.00

CDK 24D same as CDK 24 and with display ..................................................................................................... On request

Ventilation Control Products Sweden AB • +46-31-811666 • info@vcp.se • www.vcp.se 16


Carbon Dioxide (CO2) + Temperature (T) + Humidity (rH)
transmitter with colored LCD Display for room mounting
2023

Features

• Carbon Dioxide (CO2) output 0-10 Vdc

• Humidity (rH) output 0-10 Vdc

• Temperature (T) output 0-10 Vdc

• LCD display (colored)

• Carbon Dioxide (CO2) sensor


NDIR Sensor with auto calibration

• Carbon Dioxide (CO2) selectable ranges


with DIP switches
0-2000 ppm or 0-5000 ppm
RCD 010 THD
• Carbon Dioxide (CO2) accuracy
±60 ppm for range 0-2000 ppm ± 2% f.s
±150 ppm for range 0-5000 ppm ± 2% f.s

• Selectable Humidity and Temperature ranges


with DIP switches

• Temperature (T) accuracy


± 0.3°K (+5°C to +60°C) +2.5% f.s.

• Humidity (rH) accuracy


± 2% (20 to 80% rH) +2% f.s.

colored LCD Display • DIP switch on pcb to select:


to show actual value of each parameter - Relative Humidity,
CO2+T+rH
- Absolute Humidity,
- Dew Point or
- Enthalpy

__________________________________________________________________________________________________________________
Type no. Description EURO
price
__________________________________________________________________________________________________________________

RCD 010 THD Carbon Dioxide (CO2) + Temperature (T) + Humidity (rH) transmitter
with colored LCD Display for room mounting ...................................................................................... 218.00

__________________________________________________________________________________________________________________

LED display on request


RCD 010 THD is the standard type,
Green 0-800 ppm VOC sensor output on request
all other types are manufactured
Orange 800-1600 ppm
and supplied on request
Red 1600-2000 ppm

Ventilation Control Products Sweden AB • +46-31-811666 • info@vcp.se • www.vcp.se 17


Temperature sensors
NTC 10K and PT1000
2023

___________________________________________________________
Type no. Description EURO
price
___________________________________________________________

TRC NTC 10K Room temperature sensor, NTC 10K 10.00

TRC PT1000 Room temperature sensor, PT1000 10.00

TRC NTC 10K SS Room temperature sensor, NTC 10K On request

TRC PT1000 SS Room temperature sensor, PT1000 On request TRC

TRC NTC 10K SS and TRC PT1000 SS have stainless steel


(s/s) enclosure, the other TRC have ABS plastic enclosure.
___________________________________________________________

TDC NTC 10K 200 Duct temperature sensor,


NTC 10K, IP65, probe lenght 200 mm 18.00

TDC PT1000 200 Duct temperature sensor,


PT1000, IP65, probe lenght 200 mm 18.00
TDC
The TDC duct temperature sensors supplied with mounting flange,
probe length is 200mm as standard,
also 50, 100, 150, 300 and 400 mm probe lenghts available.
___________________________________________________________

TIC NTC 10K 100 Immersion temperature sensor,


NTC 10K, IP65, probe lenght 100 mm 16.00

TIC PT1000 100 Immersion temperature sensor, TIC


PT1000, IP65, probe lenght 100 mm 16.00 BRPS
SSPVA
BRPS 100 Immersion pocket,
brass, lenght 100 mm 8.00 RCD 010 THD
SSPVA 100 Immersion pocket,
stainless steel (s/s), lenght 100 mm 14.00

Probe/pocket length is 100 mm as standard,


also 50, 150, 200, 250, 300 and 400 mm probes/pockets lenghts available.
____________________________________________________________

TSE NTC 10K Strap-on temperature sensor,


NTC 10K, IP65 18.00 TSE

TSE PT1000 Strap-on temperature sensor,


PT1000, IP65 18.00

The strap-on temperature sensor TSE is included


300 mm adjustable strap-on band, for pipe diameter 32 to 50 mm.
____________________________________________________________

TSC NTC 10K 1M Strap-on temperature sensor,


NTC 10K, cable lenght 1 meter 9.00
TSC
TSC PT1000 1M Strap-on temperature sensor,
PT1000, cable lenght 1 meter 9.00

The strap-on temperature sensor TSC is included


220 mm adjustable strap-on band, for pipe diameter 32 to 50 mm.
_____________________________________________________________

TOC NTC 10K Outdoor temperature sensor,


NTC 10K, IP65 14.00

TOC PT1000 Outdoor temperature sensor,


PT1000, IP65 14.00 TOC

Ventilation Control Products Sweden AB • +46-31-811666 • info@vcp.se • www.vcp.se 18


Temperature transmitters
0-10 Vdc and 4-20 mA output
2023

________________________________________________________________________
Type no. Description Output Display EURO
price
________________________________________________________________________

TRTS 010 Room 0-10 Vdc No 88.40


TRTS 010D Room 0-10 Vdc Yes 133.80
TRTS 010 SS Room 0-10 Vdc No On request
TRTS 420 Room 4-20 mA No 88.40 TRTS
TRTS 420D Room 4-20 mA Yes 133.80
TRTS 420 SS Room 4-20 mA No On request

TRTS 010 SS and TRTS 420 SS have stainless steel (s/s) enclosure,
the other TRTS have ABS plastic enclosure.
________________________________________________________________________

TRTS
TDTH 010 200 Duct 0-10 Vdc No 111.20 s/s enclosure
TDTH 010 200D Duct 0-10 Vdc Yes 156.60
TDTH 420 200 Duct 4-20 mA No 156.60
TDTH 420 200D Duct 4-20 mA yes 145.00

The TDTH duct transmitters supplied with mounting flange,


probe length is 200mm as standard,
also 50, 100, 150, 250 and 300 mm probe lenghts available.
________________________________________________________________________
TDTH
TITB 010 100 Immersion, brass 0-10 Vdc No 110800
TITB 010 100D Immersion, brass 0-10 Vdc Yes 163.40
TITS 010 100 Immersion, s/s 0-10 Vdc No 127.00
TITS 010 100D Immersion, s/s 0-10 Vdc Yes 172.40 RCD 010 THD
TITB 420 100 Immersion, brass 4-20 mA No 118.00
TITB 420 100D Immersion, brass 4-20 mA Yes 163.40
TITS 420 100 Immersion, s/s 4-20 mA No 127.00 TITB/
TITS
TITS 420 100D Immersion, s/s 4-20 mA Yes 172.40
TITB including brass immersion pocket. TITS including stainless pocket.
Probe/pocket length is 100 mm as standard,
also 50, 150, 200, 250 and 300 mm probes/pockets lenghts available.
________________________________________________________________________

TSTH 010 Strap-on 0-10 Vdc No 111.20


TSTH 010D Strap-on 0-10 Vdc Yes 156.60
TSTH 420 Strap-on 4-20 mA No 111.20
TSTH
TSTH 420D Strap-on 4-20 mA Yes 156.60

Included 300 mm adjustable strap-on band, for pipe diameter 13 to 92 mm (1/4“ to 3“)
________________________________________________________________________

TOTP 010 Outdoor 0-10 Vdc No 102.00


TOTP 010D Outdoor 0-10 Vdc Yes 146.40
TOTP 420 Outdoor 4-20 mA No 102.00
TOTP 420D Outdoor 4-20 mA Yes 146.40 TOTP
______________________________________________________________________

Temperature transmitters TRTS, TDTH, TITB, TITS, TSTH and TOTP Other photos for TRTS, TDTH, TITB/TITS,
RCD 010 THD
have 8 different measuring temperature ranges selectable by DIP switches on pcb
-20°C to +150°C, -50°C to +50°C, -20°C to +80°C, -30°C to +60°C,
0°C to +40°C, 0°C to +50°C, 0°C to +100°C and 0°C to 150°C.
TSTH and TOTP without display can viewed on
http://www.ventilationcontrolproducts.net/temperature-transmitters

Ventilation Control Products Sweden AB • +46-31-811666 • info@vcp.se • www.vcp.se 19


Sensor Shields / Guards / Protections
2023

Features
• Weather Sensor Shield
• Protection from rain and radiated heat
Price 132 Euro
• 6 plates
• To be assemblied on wall or on pipe/mast
• Suitable on pipe/mast diameters
from 20 mm to 40 mm
• Suitable for different sensor probe diameters
• Photo show weather sensor shield RSS 100
RSS 100 assemblied together with VCP outdoor
humidity/temperature transmitter.

Features
• Sensor guard in parking garage
• Sensor guard in ball game halls
Price 58 Euro • Sunshade and weather protection
for outside wall mounted sensors
• Stainless steel
• Size 184 x 180 x 80 mm
• Simple mounting
• Photo show sensor guard SGD SS1
SGD SS1 together with VCP carbon monoxide
gas detector.

Features
• Sensor guard for room/space sensors

Price 100 Euro • Sensor guard in ball game halls


• Robust construction
• Powder coated mild steel
• Size 122 x 130 x 55 mm
• Simple mounting
• Photo show sensor guard SGD MS1
together with VCP room humidity/temperature
SGD MS1 transmitter

Features

• Stainless steel room/wall enclosure,


to be used in
ball game halls, military baracks or any room
or area where robust enclosure is required.

• Available for:
- Temperature sensors/transmitters
- Humidity/temperature transmitters
- Air Quality (VOC) transmitters
- Carbon Dioxide (CO2)transmitters

Manufactured on request.
Prices depends on sensor/transmitter type
and on the quantities.

Ventilation Control Products Sweden AB • +46-31-811666 • info@vcp.se • www.vcp.se 20


Condensation Sensors
2023

Features

• Prevents “indoor rain” condensation

• Enables optimal efficiency for


chilled beam applications

• Early detection of condensation danger

• High accuracy and long term stability

Price 60 Euro • Compact design

• Fast response time


WCS 24S
• Easy mounting and connecting

• LED status indication

Applications
• Chilled ceilings

• Heating-, ventilation- and air conditioning systems

• Switching and electronics cabinets

• In swimming pools or on shop windows around the


Price 72 Euro glazing fogging with optimized use of energy or to
keep free of ice.

WCS 24C • In water treatment plants or industrial plants to


“sweating” of cold pipeline networks to detect.

• In hangars and storage rooms to prevent condensation


on cold outside walls or steel doors and to protect the
masonry.

• In control cabinets or machines in order to detect


condensation on sensitive electronic components.

Features
• Prevents “indoor rain“ condensation

• Enabless optimal efficiency for


chilled beam applications

• Low smoke & fume flying lead cable

• Volt Free Contact or current output

• Adjustable set point

Price on request • Operates on calculated dew point

WCD 2

Ventilation Control Products Sweden AB • +46-31-811666 • info@vcp.se • www.vcp.se 21


Water Warning Detectors and
Water Detection Tape
for Detection of Water and Moisture
2023

Features

• Early detection = Early warning

• Detection of moisture and water

WLD 24, water leakage detector

• Mounting

- Directly on floor
the WLD 24 have 2 sensing parts (electrode extensions)
under the unit
WLD 24 - On the wall with external water detection tape WDT

• Switching output
Relay 60 V / 1 A, potential free changer

• Power supply 24 Vac/dc

• Sensitivity adjustable via potentiometer

• LED status indication


WDT 50

WDT, water detection tape

• WDT water detection tape is made of texturiced


stockinet-knitted polyester in which parallel
uninsulated wires of soft annealed copper are woven

• Indicates presence of
water or moisture between the wires

• The water detection tape WDT can be used with


the water leakage detector WLD 24
WDT • WDT are available in standard lengths (rolls) of
25 and 50 metres or per meter below 25 meters.

• Lengths of band can be connected by using


connection sleeves and clamping tong

__________________________________________________________________________________________________________________
Type no. Description EURO
price
__________________________________________________________________________________________________________________

WLD 24 Water leakage detector 24 Vac/dc, relay output ............................................ 96.00

WDT 25 A roll of 25 meters water detection tape .............................................................. 172.00 (6.88 Euro per meter)
WDT 50 A roll of 50 meters water detection tape ............................................................ 344.00 (6.88 Euro per meter)
WDT Water detection tape if order other lengths less than 25 meters .......................... 10.00 (10.00 Euro per meter)

Ventilation Control Products Sweden AB • +46-31-811666 • info@vcp.se • www.vcp.se 22


True Duct Smoke Detector
2023

Features

• IR-detection (obscuration)

• Outputs
Relay SPDT 1A@24Vdc, 120 Vac
Analogue2-10 Vdc

• Analogue output status levels


< 2 VdcSensor fault
< 3-7 VdcNormal operation
< 7-9 VdcOptics require cleaning
> 9,5 Vdc Smoke alarm

VSD 301 • The analogue output signal 2-10 Vdc can transmit
smoke or service alarm (dirt level) to BEMS
system

• Relay output for closing fan/damper motor


• Early warning of smoke and fire
• Damped or undamper output (jumper selection)
• Sensing smoke directly in the duct
Without help of built-in fan in the detector – • Manual or auto reset (jumper selection)
No use of sampling tubes
A True Duct Smoke Detector ! ! ! • Reset button in front of enclosure

• Power supply 24 Vac/dc

__________________________________________________________________________________________________________________
Type no. Description EURO
price
__________________________________________________________________________________________________________________

VSD 301 Duct smoke detector, 300 mm probe length ...................................................................................... 274.00
__________________________________________________________________________________________________________________

Ventilation Control Products Sweden AB • +46-31-811666 • info@vcp.se • www.vcp.se 23


Light Level Transmitters
Air Flow Paddle Switch
2023

Features

• Selectable ranges via DIP switches:

LLR: LLO:
0 to 500 Lux 0 to 500 Lux
0 to 1 kLux 0 to 1 kLux
0 to 5 kLux 0 to 2 kLux
0 to 20 kLux 0 to 5 kLux
0 to 20 kLux
LLR 010
0 to 60 kLux

• Output
0-10 Vdc for LLR 010 and LLO 010
4-20 mA for LLR 420 and LLO 420

• Accuracy < +/- 5% of final value

• Active control of artificial lighting

• Maximum energy efficiency

• Optimize light levels

LLO 010

________________________________________________________________________________________________________________
Type no. Description EURO
price
________________________________________________________________________________________________________________

LLR 010 Room light level transmitter 0-10 Vdc output ....................................................................................... 130.00

LLR 420 Room light level transmitter 4-20 mA output ........................................................................................ 130.00

LLO 010 Outdoor light level transmitter 0-10 Vdc output ................................................................................... 140.00

LLO 420 Outdoor light level transmitter 4-20 mA output ..................................................................................... 140.00

Features
• Monitoring of flow and non-agressive gaseous

• IP65 plastic housing

• Base in galvanized steel

• Moving arm in brass

• Vane in stainless steel

Price 76 Euro Min. switch on 2.5 secs


Min. switch off 1.0 sec
Max switch on 9.2 secs
Max switch off 8.2 secs

Application
Air flow paddle switch FAPS is intended to monitor
air flow and non-agressive gaseous within a duct
and provides a switched output on detection of either
FAPS a specified air velocity or flow failure.

Ventilation Control Products Sweden AB • +46-31-811666 • info@vcp.se • www.vcp.se 24


Room Thermostats
2023

Features

• Bright back-lit display with interactive touch screen

• Adjustable manual 3-speed or


automatic fan speed control,
High, Medium and Low

TST 8MV • Setting point range +10 to +30°C

• Accuracy +/-1 °C

• NTC thermistor sensing element

• Power supply 220 Vac

• Setting Turn on/off within 24 hours

• Data Memory:
If the power cut off accidentally, it could be
Production for TST 8C, TST 8E and TST 8MV continuing to work by order if the power returns
been stopped, new thermostats will be replaced
• Attractive modern styling and smart outlooking
the TST 8C, TST 8E and TST 8MV during 2023. (12 mm only for surface board)

Ask for stock sales out price for


TST 8C, TST 8E and TST 8MV. Applications

- Fan coil unit - Two-line Motorized Valve


- Three-line Motorized Valve - Solenoid Valve
- Heating Equipment - Three-speed angle fan valve

________________________________________________________________________________________________________________
Type no. Description EURO
price
________________________________________________________________________________________________________________

Touch Screen Thermostat, Heating Cooling

TST 8C 2-pipe system, controls fan coil and 3-wire motorized valve with 3 Fan Speed .................. Ask for stock sales out price

TST 8E Four-pipe systems, controls fan coil and 2-wire or 3-wire motorized valve with 3 Fan Speed. Ask for stock sales out price

TST 8MV Modulating 0-10 Vdc with 3 Fan Speed. ............................................................................. Ask for stock sales out price

Features

• Fan speed switch


- 3 speed (HIGH-MED-LOW)

• HEAT-OFF-COOL switch
Price 23.00 Euro
• Setpoint knob with range +10 to +30°C

• Power supply 220 Vac

FAPS

MRT 31A

Ventilation Control Products Sweden AB • +46-31-811666 • info@vcp.se • www.vcp.se 25


Zone Valves and Actuators
2023

AZP 1401 AZD 1404

VZ2 160 VZ4 100 VZ3 250

Zone Valves VZ-series Actuators AZ-series


• 2-way, 3-way and 3-way 4-port valves • AZ-series actuators to be used with
VZ-series DN15 and DN20 valves with
• Sizes DN15 and DN20 (1/2 inch and ¾ inch) kvs value from 0.25 up to to 6.0

• Kvs values from 0.25 up to 6.0 • Actuating force 140 N

• Brass valve body • Control Signals


On/Off , PWM (Pulse With Modulation ) or 0-10 Vdc
• Operating pressure 16 Bar (PN16)
• Normally Closed (NC)
• Stainless steel stem
• Stroke length 2.5 mm
• Stroke length 2.5 mm
• Position indicator
• Stem tight double OR ring in EPDM
• Fast and easy assembling of actuator on valve
• Seat in technopolymer with a threaded ring nut

• Threaded male collar M30x1.5 for fitting of actuator • The ring nut M30x1.50 suppiled with the actuator
Threaded ring nut for other valve brands on request
• All VZ-valves are Normally Closed (NC),
i.e. the action of the valve spring makes the plug • Supplied with 2 meter cable
move to the upper seat, even with disassembled
actuator. • Applied in hot and chilled applications

______________________________________________________ ______________________________________________________
Type no. Body Size Kvs Kvs EURO Type no Control Power Euro
zone direct angle price actuator signal supply price
valve way way
______________________________________________________ ______________________________________________________

VZ2 100 2-way 1/2" (DN15) 1.0 ............... 20.20 AZD 1404 on/off or PWM 24 Vac/dc ........... 23.08
VZ2 160 2-way 1/2" (DN15) 1.6 ................ 20.20
VZ2 250 2-way 3/4" (DN20) 2.5 ................ 21.76
VZ2 400 2-way 3/4" (DN20) 4.0 ................. 46.84 AZD 1403 on/off 230 Vac ................ 23.08
VZ2 600 2-way 3/4" (DN20) 6.0 .................. 46.84

VZ3 100 3-way 1/2" (DN15) 1.0 0.6 ........ 22.64 AZP 1401 0-10 Vdc 24 Vac ................ 77.48
VZ3 160 3-way 1/2" (DN15) 1.6 1.0 ….... 22.64 ______________________________________________________
VZ3 250 3-way 3/4" (DN20) 2.5 1.6 ........ 24.20
VZ3 400 3-way 3/4" (DN20) 4.0 2.5 …... 49.28
VZ3 600 3-way 3/4" (DN20) 6.0 4.0 ……... 49.28

Zone valves with kvs value 0.25, 0.40 and 0.60 on request
3-way 4-port valve on request.
Zone valves VZ-series
assemblied with
actuators AZ-series

Ventilation Control Products Sweden AB • +46-31-811666 • info@vcp.se • www.vcp.se 26


Thermoelectric Valve Actuators A-series
with Adaptors Suitable with
VZH Zone Valves and Other Valve Brands 2022

Features
• Control signals
on/off or Pulse Width Modulation (PWM)
or 0-10 Vdc

• Normally Closed

• Stroke lenght 4.0 mm

• Force 100 N

Adaptor to be used between actuator and valve.

Adaptors availvable to more than 50


valve brands on the market.

For examples:

Honeywell, Siemens (Landis & Staefa), Danfoss,


Johnson Controls, Sauter, Tour & Anderson,
MMA (Markaryd), Cazzaniga, Herz, Oventrop,
Heimeier and many more.

Valve adaptors can be used on new and existing valves

____________________________________________________________________________________________________________
Type no. Description Power Control EURO
supply signal price
____________________________________________________________________________________________________________

A 40405-10N00 Actuator without valve adaptor 24 Vac/dc on/off or PWM .............................. 25.40

A 20405-10N00 Actuator without valve adaptor 230 Vac on/off or PWM .............................. 25.40

APR 40405-00N00 Actuator without valve adaptor 24 Vac 0-10 Vdc ............................................ 10.00

VA 80 Valve adaptor for VCP VZH valves,


Heimeier, Tour & Andersson as of 1999, Honeywell V9050,
Johnson Controls V5210KC, V5510KC,
Sauter VXL F200 & 210, BXL F200 & 210, BUT 010 F410 ........................................................ 1.76

VA 50 Valve adaptor for Landis & Gyr, Siemens VDN 215, Watts/Cazzaniga,
Sauter VXLF220, BUT015 F410, BUT010 F400, BUT015 F210, Herz ...................................... 1.76

VA 78 Valve adaptor for Danfoss RA (RA N, RA UN) high flange ........................................................ 4.18

Adaptors for other valve brands available, see data sheet for more information.

Actuators with other features, see data sheet for more information.

Ventilation Control Products Sweden AB • +46-31-811666 • info@vcp.se • www.vcp.se 27


Non-Spring Return Damper Actuators
Torque 2 Nm
2023

Features
• Torque 2 Nm
to regulate dampers up to approx. 0.5 m²

• Control signal
RA2 24 D = on/off
RA2 220D = on/off
RA2 24V = 2-10 Vdc

• Feedback signal
2-10 Vdc for RA2 24V

RA2 24D • Power supply


RA2 24 D = 24 Vac/dc
RA2 220D = 220 Vac
RA2 24V = 24 Vac/dc

• Position indicator

• Manual override by push button

• Direction of rotation changeable


via L/R switch outside damper actuator

• Supplied with 0.9 m cable

• Rotation angle max 95°

• Auxiliary switch on request

____________________________________________________________________________________________________________
Type no. Torque For dampers Control Power Running EURO
up to approx. signal(s) supply time price
____________________________________________________________________________________________________________

RA2 24D 2 Nm 0.5 m² On/off 24 Vac/dc 30-35 sec ............. 53.00

RA2 220D 2 Nm 0.5 m² On/off 220 Vac 30-35 sec ............. 55.00

RA2 24V 2 Nm 0.5 m² 2-10 Vdc 24 Vac/dc 80-110 sec ........... 62.00

___________________________________________________________________________________________________________

Ventilation Control Products Sweden AB • +46-31-811666 • info@vcp.se • www.vcp.se 28


Non-Spring Return Damper Actuators
Torque 4, 8, 16, 24 and 32 Nm
2023

Features
• Torques 4 Nm, 8 Nm, 16 Nm, 24 Nm and 32 Nm

• Max size of damper shaft for


4 Nm damper actuators
- Round shaft 16 mm in diameter
- Square shaft 12x12 mm

• Max size of damper shaft for


8, 16, 24 and 32 Nm damper actuators
- Round shaft 20 mm in diameter
RA4 24V - Square shaft 16x16 mm

• Feedback signal 2-10 Vdc


on analogue damper actuators 8, 16, 24 and 32 Nm

• Rotation angle 0-90°

• Position indicator

• Manual override by push button

• Direction of rotation changaeble

• Anti-rotation bracket provided for stability

RA16 24VC On request


- Auxiliary switches
- Fast running time actuators

____________________________________________________________________________________________________________
Type no. Torque For dampers Control Power Running EURO
up to approx. signal(s) supply time price
____________________________________________________________________________________________________________

RA4 24D 4 Nm 1.0 m² On/off or 3-point 24 Vac/dc 35 secs 73.00

RA4 220D 4 Nm 1.0 m² On/off or 3-point 220 Vac 35 secs 77.00

RA4 24V 4 Nm 1.0 m² 0-10 Vdc 24 Vac/dc 35 secs 85.00


____________________________________________________________________________________________________________

RA8 24D 8 Nm 2.0 m² On/off or 3-point 24 Vac/dc 30 secs 95.00

RA8 220D 8 Nm 2.0 m² On/off or 3-point 220 Vac 30 secs 101.00

RA8 24VC 8 Nm 2.0 m² 2-10 Vdc or 4-20 mA 24 Vac/dc 30 secs 109.00


____________________________________________________________________________________________________________

RA16 24D 16 Nm 4.0 m² On/off or 3-point 24 Vac/dc 80 secs 102.00

RA16 220D 16 Nm 4.0 m² On/off or 3-point 220 Vac 80 secs 108.00

RA16 24VC 16 Nm 4.0 m² 2-10 Vdc or 4-20 mA 24 Vac/dc 80 secs 116.00


____________________________________________________________________________________________________________

RA24 24D 24 Nm 6.0 m² On/off or 3-point 24 Vac/dc 125 secs 108.00

RA24 220D 24 Nm 6.0 m² On/off or 3-point 220 Vac 125 secs 114.00

RA24 24VC 24 Nm 6.0 m² 2-10 Vdc or 4-20 mA 24 Vac/dc 125 secs 122.00
____________________________________________________________________________________________________________

RA32 24D 32 Nm 8.0 m² On/off or 3-point 24 Vac/dc 140 secs 128.00

RA32 220D 32 Nm 8.0 m² On/off or 3-point 220 Vac 140 secs 134.00

RA32 24VC 32 Nm 8.0 m² 2-10 Vdc or 4-20 mA 24 Vac/dc 138 secs 142.00

Ventilation Control Products Sweden AB • +46-31-811666 • info@vcp.se • www.vcp.se 29


Spring Return Damper Actuators
Torque 5, 10 and 15 Nm
2023

Features
• Torques
5 Nm for RAR5-series
RAR5 220D 10 Nm for RAR10-series
15 Nm for RAR15-series

• Suitable damper shaft dimensions

RAR5:
Round shaft 10-16 mm in diameter
Square shaft 7-11 mm

RAR10 and RAR15:


Round shaft 10-19 mm in diameter

Square shaft 10-16 mm

RAR15 220D S2 • Power supply 24 Vac/dc or 220 Vac

• Control signal on/off

• Auxiliary switches available

• Position indicator

• Anti-rotation bracket provided for stability

____________________________________________________________________________________________________________________
Type no. Torque For dampers Control Power Running Auxiliary EURO
up to approx. signal(s) supply time switch(es) price
____________________________________________________________________________________________________________________

RAR5 24D 5 Nm 1.0 m² On/off 24 Vac/dc actuator < 50-70 s No 118.00


spring < 20 s

RAR5 220D 5 Nm 1.0 m² On/off 220 Vac actuator < 50-70 s No 130.00
spring < 20 s

RAR5 24D S2 5 Nm 1.0 m² On/off 24 Vac/dc actuator < 50-70 s Yes (2) 136.00
spring < 20 s

RAR5 220D S2 5 Nm 1.0 m² On/off 220 Vac actuator < 50-70 s Yes (2) 148.00
spring < 20 s
____________________________________________________________________________________________________________________

RAR10 24D 10 Nm 2.0 m² On/off 24 Vac/dc actuator 100 s No 138.00


spring < 25 s

RAR10 220D 10 Nm 2.0 m² On/off 220 Vac actuator 100 s No 150.00


spring < 25 s

RAR10 24D S2 10 Nm 2.0 m² On/off 24 Vac/dc actuator 100 s Yes (2) 156.00
spring < 25 s

RAR10 220D S2 10 Nm 2.0 m² On/off 220 Vac actuator 100 s Yes (2) 168.00
spring < 25 s
____________________________________________________________________________________________________________________

RAR15 24D 15 Nm 3.0 m² On/off 24 Vac/dc actuator 180 s No 182.00


spring < 30 s

RAR15 220D 15 Nm 3.0 m² On/off 220 Vac actuator 180 s No 194.00


spring < 30 s

RAR15 24D S2 15 Nm 3.0 m² On/off 24 Vac/dc actuator 180 s Yes (2) 200.00
spring < 30 s

RAR15 220D S2 15 Nm 3.0 m² On/off 220 Vac actuator 180 s Yes (2) 212.00
spring < 30 s

Ventilation Control Products Sweden AB • +46-31-811666 • info@vcp.se • www.vcp.se 30


General Information
2023

Address etc.
Delivery Terms
Ventilation Control Products Sweden AB
is located in Partille on the Swedish west coast near Göteborg. Delivery term is initially Ex.works.

Ventilation Control Products Sweden AB Transport cost is extra, without transport insurance, untaxed, duty unpaid.
Brodalsvägen 7, Hus Z
433 38 Partille VCP can put transport cost (CPT) or transport cost transport insurancecost (CIP)
Sweden on the invoice to the customer. CPT is standard used from 2023 on VCP invoices
when not Ex.works.
Phone: +46(0)31-811666
Web:www.vcp.se
E-mail info@vcp.se Ordering

Orders can be placed by e-mail or fax.


Strategy
When placing orders, please specify:
Ventilation Control Products Sweden AB (VCP) is a supplier of peripherial
control products for building and industrial automation, main Invoice address.
customers are HVAC contractors, OEM and distributors. Delivery address (if other than invoice address).
Your reference.
VCP delivers to customers world-wide. Your VAT number (only required for EU-countries).
Purchase order number (PO NO).
“VCP products are designed and used as field control products Type number, description and quantities for each product.
to be integrated with HVAC control systems such Required delivery-date.
BAS = Building Automation System, BMS = Building Management System, Transport company.
BEMS = Building Energy Management System, BAMS = Building Automation,
Management Systems, DDC = Direct Digital Controls
FMS = Facility Management Systems, Some countries/companies require legalized/stamped document(s).
FMIS = Facility Management Information Systems,
HVAC controls = Heating, Ventilation and Air Conditioning controllers. Please specify if you want legalized (stamped) documents such
Certificate of Origin, Original invoice, Certificate of Conformity or
VCP delivers quality products directly to customers world-wide any other document (s)legalized (stamped) from Chamber of Commerce.
without any exclusive agent partner.
Without using exclusive agent partners, customers can buy Or if you want EUR1 or ATR document stamped of Swedish Customs.
products directly at lower cost.
Each legalized (stamped) document from Chamber of Commerce costs 60 Euro.
We ship small, medium and large orders with suitable
transport companies. Each stamped document from Swedish Customs costs 30 Euro.
We can offer several different alternatives for transports.
Customers can also use their own courier or forwarder. Advise if stamped/legalized document(s) should be sent along with AWB
when shipping is with conventional air freight, or if stamped document(s)
should be sent together with goods when shipping is with courier or if stamped document(s)
Product Documentation should be sent separately with courier or how to send the stamped/legalized document(s).

Product documentation (datasheets) of VCP standard products If you are using your own courier
are available in pdf-format to download on our web-site: www.vcp.se. DHL, Fedex, TNT UPS or any other:
Please advice your account number valid for import
Data sheets include product photo, features, description, and type of service.
applications, technical data, dimension drawing, electrical connection etc. For example:
UPS Express Saver service,
our import account number xxxx.
Prices
If you are using your own forwarder:
Prices are available in this catalogue. Road (truck) freight, air freight or sea freight.
Please advise forwarding company and phone number.

Delivery Times
Return
Delivery-time is depending on:
product-type(s), quantities, other orders in process and holiday seasons. If wrong product have been ordered or any product claim to be faulty,
and you want to return any product to us, please contact us before you return
Delivery-time is normally within 3-4 weeks, any product to us.
some orders are shipped out directly from our stock.
Shipping cost for return product to us to be bear of the shipper.
Delivery time for gas detectors is normally 5 weeks after receipt of payment.
If product return from outside European Union, please issue proforma
Delivery time can be 2 weeks longer because of holiday seasons. invoice for the customs clearing, and write on proforma invoice:
"Return of product, For customs value 10 Euro".
For non-frequent products / non-standard products, we want pre-payment
before process the order to production.
Administration surcharge
For first order from new customer,
we require pre-payment before process the order to production. Administration surcharge 25 Euro
for order with product amount less than 500 Euro.
You can ask for current delivery time. Specify: product type(s) and quantities.

Disclaimer
Payment Terms
We reserve our rights in this catalogue:
Payment term is pre-payment before shipping. For any printing error as prices, technical data etc.
For higher amounts we may use Letter of Credit. To change prices.
To make changes in our products.
For non-standard products and non-frequent products
we use pre-payment before processing the order.

We send You proforma invoices with our bank details for the pre-payment.
We cannot handle any credit card payment , cheque payment, cash payment
or Western Union payment.

Ventilation Control Products Sweden AB • +46-31-811666 • info@vcp.se • www.vcp.se 31


Shippings
2023

We deliver World Wide with courier express and courier economy to your company door

And for heavy shipments outside Europe we can ship with

air freight to your nearest airport or by sea to your nearest port.

You may courier DHL, Fedex, TNT UPS or Aramex with own account to pick up goods with
and You can also use Your own truck forwarder, air freight forwarder or sea freight shipping company to pick up goods with.

Pick up address is same as our office address:

Company: Ventilation Control Products Sweden AB Contact person: Niclas Johansson


Street address: Brodalsvagen 7, Hus Z Phone: +46(0)31-811666
Postal code: 433 38 E-mail: niclas.johansson@vcp.se
Postal address: Partille
Country: Sweden

Ventilation Control Products Sweden AB • +46-31-811666 • info@vcp.se • www.vcp.se 32

You might also like