You are on page 1of 5

Document no: HTS/ENS 34207-16

Issue number 1
Page 1 of 5

Design Appraisal Document


Lloyd's Register EMEA Date
Hamburg Technical Support Office 20 May 2016
Am Sandtorkai 41
20457 Hamburg Please quote this reference number on all future communications
Telephone +49 (0)40 328107-0 Fax +49 (0)40 328107-480 HPC 1510384/34449-16/JW/MC (ETS 34054-16/TM/JB)
E-mail: hamburg-technical-support@lr.org

MACHINERY GENERAL DESIGN APPRAISAL


ISSUED TO: TROJAN MARINEX
FOR: BALLAST WATER TREATMENT SYSTEM

VALID UNTIL 04.04.2021

The plans listed in the appendix to this Marine Design Appraisal Document supersede and
supplement the corresponding plans listed in Marine Design Appraisal Document No.
HTS/ENS 34207-16, Issue no. 0, dated 05.04.2016

1 The documents listed in the appendix have been examined for compliance with Part 5, Chapters 12,
13, 14 and 25 and Part 6, Chapters 1 and 2 of the Rules and Regulations for the Classification of
Ships, January 2016 and is/are assigned an appraisal status as indicated, in accordance with the
following conditions:-

2 Machinery
3
System Treatment Rated capacity [m /h]
TM
Trojan Marinex BWT Model 150 150
Trojan Marinex BWTTM Model 500 500
Trojan Marinex BWTTM Model 750 750

3 Details

Related to the configuration the systems consist out of following components:


- Control and Power Cabinet (CPC)
- Control Cabinet
- Auxiliary Control Cabinet
- Power Distribution Cabinet (PDC)
- Hydraulic Cabinet (HC)
- Air Cooled Lamp Driver Cabinet (LDC)
- Liquid Cooled Lamp Driver Cabinet

FINAL ACCEPTANCE OF ACTUAL ITEM(S) DEPEND(S) ON SATISFACTORY SURVEY AND TESTING

Lloyd's Register EMEA


Is a member of Lloyd’s Register group

Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause as
'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or
advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or
advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

Form 6438MARREF (2016.05)

This is a copy of an electronic document. In the event of any conflict or ambiguity between the copy and the electronic document,
which is retained and published by Lloyd's Register, the original electronic and certified version shall always prevail.
Document no: HTS/ENS 34207-16
Issue number 1
Page 2 of 5
Lloyd's Register EMEA Date
Hamburg Technical Support Office 20 May 2016
Am Sandtorkai 41
20457 Hamburg Please quote this reference number on all future communications
Telephone +49 (0)40 328107-0 Fax +49 (0)40 328107-480 HPC 1510384/34449-16/JW/MC (ETS 34054-16/TM/JB)
E-mail: hamburg-technical-support@lr.org

4 Comments from electrical department

4.1 This Document is not covering electrical aspects according Part 6, Chapter 2, Section 14. (Electrical
equipment for use in explosive gas atmospheres or in the presence of combustible dusts).

4.2 It is noted that supply cables are not scope of supply. Nevertheless the cable temperature class and
the nominal cross-section has to be in accordance with the requirements of Table 2.11.3 of the Rules
and Regulation Part 6, Chapter 2. Final arrangement is to be to the local surveyor’s satisfaction.
AQS

4.3 The utilized software version(s) needs to clearly identify in the relevant test schedule. Any changes of
software versions are to be documented as well with information to the local Surveyor. AQS

5 Comments from machinery department

5.1 Material used for the Ballast Water Treatment System is to be manufactured and tested in
accordance with the requirement of the Rules for the Manufacture, Testing and Certification of
Materials.

5.2 Installation in the ship including by-pass and isolation arrangement, fresh water supply, water drain,
flow meter, sampling points and flow control valve is to be in accordance with P&ID overview
928002 E and the Installation manual and instructions. AQS

5.3 By-pass and isolation valves are to be provided with remote means of operation and position
indicators to give remote indication of the valve position. AQS

5.4 Failure of the ballast water treatment power or control system is not to restrict by-pass or isolation
arrangements or alternatively it is to be demonstrated that the fail safe arrangement is in place to
ensure the function of by-pass and isolation arrangements. AQS

5.5 Air relief valves are to demonstrate that the risk of leakage is prevented. Vent arrangements are to
be directed to a safe location on open deck. AQS

5.6 The ship specific installation of the ballast water treatment system is to be approved on a case by
case basis by the design support office responsible for plan approval of the vessel piping systems and is
to be in compliance with Part 5, Chapter 25 of the Rules.

FINAL ACCEPTANCE OF ACTUAL ITEM(S) DEPEND(S) ON SATISFACTORY SURVEY AND TESTING

Lloyd's Register EMEA


Is a member of Lloyd’s Register group

Form 6438MARREF (2016.05)

This is a copy of an electronic document. In the event of any conflict or ambiguity between the copy and the electronic document,
which is retained and published by Lloyd's Register, the original electronic and certified version shall always prevail.
Document no: HTS/ENS 34207-16
Issue number 1
Page 3 of 5
Lloyd's Register EMEA Date
Hamburg Technical Support Office 20 May 2016
Am Sandtorkai 41
20457 Hamburg Please quote this reference number on all future communications
Telephone +49 (0)40 328107-0 Fax +49 (0)40 328107-480 HPC 1510384/34449-16/JW/MC (ETS 34054-16/TM/JB)
E-mail: hamburg-technical-support@lr.org

5.7 The pressure vessels model 150, 500 and 750 are covered by Machinery General Design Appraisal
Document No. HTS/ENS 34206-16.

Johannes Wiegel
Hamburg Technical Support Office

Lloyd's Register EMEA


LR031.1.2013.12

Johannes Wiegel
Specialist
Engineering Systems
Hamburg Technical Support Office
Lloyd's Register EMEA
T +49 (0)40 328107-462
E johannes.wiegel@lr.org

FINAL ACCEPTANCE OF ACTUAL ITEM(S) DEPEND(S) ON SATISFACTORY SURVEY AND TESTING

Lloyd's Register EMEA


Is a member of Lloyd’s Register group

Form 6438MARREF (2016.05)

This is a copy of an electronic document. In the event of any conflict or ambiguity between the copy and the electronic document,
which is retained and published by Lloyd's Register, the original electronic and certified version shall always prevail.
Document no: HTS/ENS 34207-16
Issue number 1
Page 4 of 5
Lloyd's Register EMEA Date
Hamburg Technical Support Office 20 May 2016
Am Sandtorkai 41
20457 Hamburg Please quote this reference number on all future communications
Telephone +49 (0)40 328107-0 Fax +49 (0)40 328107-480 HPC 1510384/34449-16/JW/MC (ETS 34054-16/TM/JB)
E-mail: hamburg-technical-support@lr.org

Appendix

Document No. Rev. Title Status Date

DANAK -19/15017 - DELTA Test Report SI 05/04/16


DANAK - 19/15190 - DELTA Test Report SI 05/04/16
DC280901 - TROJANUV - Risk assessment calculation SI 05/04/16
TAP000001C - MEPC.174(58) certificate (DNVGL) SI 05/04/16
Unnumbered 5.2 Technical Specification (Product overview) SI 20/05/16
DC280101-04-05 4 Operation and Maintenance User Manual SI 05/04/16
DC280301-04-05 4 Installations Manual SI 05/04/16
Unnumbered 1.5 Control Philosophy (CP) SI 05/04/16
15-1176 E Engineering Specification (ES) SI 05/04/16
Unnumbered 1.0 Engineering - Software Revision Control Standard SI 05/04/16
DS0075 A Design Specification (DS) SI 05/04/16
DC281301-004-01- - Product Drawing Package SI 05/04/16
01
MX0256 4 150/250 Vertical Treatment Overview SI 05/04/16
MX0252 4 150/250 LH Horizontal Treatment Unit Overview SI 05/04/16
MX0263 4 500‐1500 Vertical Treatment Unit Overview SI 05/04/16
MX0253 4 500‐1500 LH Horizontal Treatment Unit Overview SI 05/04/16
MX0206 2 Treatment Unit Assy, Typical SI 05/04/16
MX0172 E Lamp Assembly, Marinex SI 05/04/16
MX0211 2 Filter Element, Marinex SI 05/04/16
908041G B Sleeve, Quartz SI 05/04/16
MX0077 D Overview, Auxilary Control Cabinet Assy SI 20/05/16
MX0076 D Overview, Hydraulic Cabinet Assy SI 20/05/16
MX0067 C Overview, Lamp Driver Cabinet Assy LC Dbl SI 20/05/16
MX0066 C Overview, Lamp Driver Cabinet Assy LC SI 20/05/16
MX0087 E Overview, Lamp Driver Cabinet Assy AC SI 20/05/16
MX0009 D Overview, Control & Power Cabinet Assy 150/250 SI 20/05/16
MX0197 D Overview, Control & Power Cabinet Assy 500/750 SI 20/05/16
MX0193 C Overview, Control & Power Cabinet Assy 1000‐ SI 20/05/16
1500
MX0259 2 150 ‐ 750 Vertical Process Tie Point Locations SI 05/04/16
MX0260 2 1000 ‐ 1500 Vertical Process Tie Point Locations SI 05/04/16
MX0261 2 150 ‐ 1500 LH Horizontal Tie Point Locations SI 05/04/16
FINAL ACCEPTANCE OF ACTUAL ITEM(S) DEPEND(S) ON SATISFACTORY SURVEY AND TESTING

Lloyd's Register EMEA


Is a member of Lloyd’s Register group

Form 6438MARREF (2016.05)

This is a copy of an electronic document. In the event of any conflict or ambiguity between the copy and the electronic document,
which is retained and published by Lloyd's Register, the original electronic and certified version shall always prevail.
Document no: HTS/ENS 34207-16
Issue number 1
Page 5 of 5
Lloyd's Register EMEA Date
Hamburg Technical Support Office 20 May 2016
Am Sandtorkai 41
20457 Hamburg Please quote this reference number on all future communications
Telephone +49 (0)40 328107-0 Fax +49 (0)40 328107-480 HPC 1510384/34449-16/JW/MC (ETS 34054-16/TM/JB)
E-mail: hamburg-technical-support@lr.org

Appendix

Document No. Rev. Title Status Date

928002 E P&ID, Marinex Overview A 05/04/16


507257G C WD, MRX OVERVIEW 500‐750CB A 20/05/16
507252G B WD, MRX OVERVIEW 1000‐1500CB A 05/04/16
507306G C WD, MRX INTERCONNECT 150‐250 A 20/05/16
507256G D WD, MRX CPC INTERCON 500‐750 A 20/05/16
507253G B WD, MRX CPC INTERCON 1000‐1500 A 20/05/16
506403 P Wiring Diagram, CPC 150/250 A 20/05/16
507101 E Wiring Diagram, CPC 500/750 A 20/05/16
507248G B Wiring Diagram, CPC 1000 ‐ 1500 A 20/05/16
506015 B Switch, Level VIB G3/4 SI 05/04/16
506176 C Level Switch, VIB FK G3/4" ISO SI 05/04/16
506175 C Temperature SW & SENSOR, G1/2 MRX SI 05/04/16
794528 B Sensor, Amalgam DVGW 40 Deg SI 05/04/16
916642 A Sensor, Press Transducer G1/4 SI 05/04/16
907764G A Gauge, Press BSPP ‐1 / 1600BAR SI 05/04/16
506730 B Air Eliminator, 3/4" x 3/8" BSPT SI 05/04/16

Appraisal Status Key

A Approved - provided the arrangements are to the surveyor's satisfaction


AQS Details to be submitted by the client to the local surveyor’s Office responsible for surveying the
building and the arrangements verified in accordance with the Rule/Regulations requirements by
the surveyor.
SI Retained as supporting documentation for information only

FINAL ACCEPTANCE OF ACTUAL ITEM(S) DEPEND(S) ON SATISFACTORY SURVEY AND TESTING

Lloyd's Register EMEA


Is a member of Lloyd’s Register group

Form 6438MARREF (2016.05)

This is a copy of an electronic document. In the event of any conflict or ambiguity between the copy and the electronic document,
which is retained and published by Lloyd's Register, the original electronic and certified version shall always prevail.

You might also like