Course Outcomes: On completion of the cours’, @ student will be able to:
1. Recommend the type of footing based onload tobe transfered and soil
characteristics
2, Perform design of shallow and deep foundations and retaining wall based on
load and soil characteristics
Perform the design of water retaining structures.
Understand the concepts of pre-stressing in concrete
the materials for pre-stressing.
5, Analyze a pre-stressed concrete section and estimate losses of pre-stressing
and design of prestressed beams
structures and identify
“Answer Any Two questions
le No | Questions Marks | BL | CO | PO/PSO
(a) | Expsin the concept of load balancing with 123.455, |
| reference to prestressed beams ? 3 | ca | 4 |
\bA prestressed concrete rectangular beam 300 123,45,
| 12/123
mmx600mm is prestressed with prestressing force
of 1200 KN applied at 125 mm from soffit. The
span of the beam is 6 m and carries imposed load
(b) | of 6OKN cach at 1/3 span. Find the extreme fiber
Stress at mid span section and draw stress
distribution diagram under (i) initial prestress and
no imposed load and (ji final condition; assume
loss as of 20%.
95 | 14 | 4,5
‘What is meant by () Circular prsetrssing and (i) 12,345.
(2) | Thermo electric prestressin;
‘A post tensioned, simply supported beam 200mmx
{600 mm of span 12 m which is prestressed with a
parabolic cable that has a maximum eccentricity of
150 mm at mid span and zero eccentricity at
supports. The cable is jacked from both ends. Given
the following; (i) Cable consists of 24 wires each of
7T mam diameter (i) Initial prestress in stee! is limited
to 0.8 times the characteristic strength of steel, it)
(6) | anchorage slip = 1.5mm (jv) consider ary
atmospheric condition with RH = 509%, (¥) wite
Cables are housed in lead coated ducts (vi)
Characteristic strength of steel = 1600 N/mm (vi)
Characteristic strength of conerete = 40 ‘Nimny,
Es-200 kN/mm2, Determine the maximum
prestress and effective prestress with the giv
and using guidelines in IS 134:Explain ker of the section with proper illustration
Design section, prestressing force, eccentricity of
cable and area of steel for a pretensioned
| prestressed concrete beam carrying a live load of 20
kN/m over a span of 18 m. The permissible stress in
compression is limited to 14 N/mm? both at transfer
and working state. The member is to be designed as
Type 1. Assume 20% loss in prestress. Use M40
conerete, Characteristic strength of steel is 1800
Nimm?,