Design Guide Tables
Design Guide Tables
TYPE I Wood Construction NON-FIRE Siting of buildings/structures are permitted without OCCUPANCY REQUIRED PARKING
RESTRICTIVE fire-resistivity measures, often located in the
Wood Construction with protective fire-resistant materials country sides or rural areas Low income single detached living unit
TYPE II ZONES (Type I & II)
(1 Hour)
with individual lots not more 1 slot/10 units
Masonry and Wood Construction FIRE Siting of buildings/structures are permitted within than 100m²
TYPE III
prescribed fire-resistivity measures for exterior
RESTRICTIVE
walls of at least two-hour fire resistivity, located in
TYPE IV Steel, Iron, Concrete, or Masonry Construction (1Hour) ZONES (Types II, III, IV) suburban areas Multi-family living units regardless of
no. of stories with average living floor 1 slot / 8 units
HIGHLY FIRE area of 50m²
TYPE V Steel, Iron, Concrete, or Masonry Construction (4hours) Siting of buildings/structures are permitted within
RESTRICTIVE
prescribed fire-resistivity measures for exterior
ZONES walls of at least two-hour fire resistivity. Multi-family living units regardless of
(Types IV and V) no. of stories with average living floor 1 slot / 8 units
CLASSIFICATION OF BUILDINGS BY USE area of above 50m² to 100m²
OR OCCUPANCY (RULE VII)
PARKING REQUIREMENTS Multi-family living units regardless of
no. of stories with average living floor 1 slot/1 unit
GROUP TYPE DIVISIONS ZONES area of more than 100m²
OCCUPANCY REQUIRED PARKING
RESIDENTIAL
A A1, A2 R-1, R-2
DWELLINGS Amusement centers 1 slot/ 50m² of gross floor area Hotels 1 slot/ 10 rooms
RESIDENTIALS, Clubhouses, beach houses, etc. 1 slot/ 100m² of gross floor area Residential hotels and apartels 1 slot/ 5 units
B HOTELS AND B-1, B-2 R-3, R-4, R-5
APARTMENTS Factories, manufacturing, mercantile,
1 slot/ 1000m² of gross floor area Motels 1 slot/ 1 unit
warehouses and storage bin
EDUCATION &
C C-1, C-2 GI
RECREATION Tourist bus parking 2 bus slots/ hotel or theater restaurant Shopping centers 1 slot/ 100m²
Pedestrian Crossings Extension 0.30 m (Start / End of Ramps / Stairs) Walkway 1.20 m (Between front ends of cars)
Locations
End of walkways of a private street or access road Full Grip 30 mm to 50 mm Dropped Curbs and Cut-Outs @ Raised Walkways
Width Same width of crossing or 0.90 m (Min.) Clearance 50 mm (Walls); 40 mm (Ledges) Pavement Markings, Signs To delineate parking spaces for PWD
Slope 1:12 Towards adjoining curb, 1:20 towards Road SIGNAGES INSIDE BUILDINGS & STRUCTURES
Lowest Point 25 mm (Max.) from Road / Gutter Location Point Conveniently seen by PWD ENTRANCES
CURB CUT-OUTS Contrasting Colors and Contrasting Location Lobby Arrival & Departure Points
Color / Texture Gray Matter to make detection and
When allowed Does not obstruct a walkway or lessen its width reading easy Elevator Access 1 Entrance Level
Width 0.90 m Headroom 2.00 m Provide if Site Arrival grade is not same level as
Ramps
Entrance Level
Slope / Gradient 1:12 Height 1.60 m (Max.); 1.40 m (Min.)
WALKWAYS AND PASSAGEWAYS Raised Symbols , Letters, Numbers 1 mm; Braille Symbols Included Vestibules 1.80 m (D) x 1.50 m (W)
Slope / Gradient 1:20 or 5% Near Perpendicular to Carriageway Width (Clear) 1.20 m (Min.)
Location
Narrowest, Most Convenient Part
Cross Gradient 1:100 Gradient 1:12
Close / Contiguous with Normal
Width 1.20 m Pedestrian Desire Line Length (1:12 Gradient) 6.00 m, (if longer add 1.50 m landing)
Gratings 13 mm x 13 mm, 6.5mm (Max.) Projection Central Refuge (10.00m Carriageway) 1.50 m (Min.), 2.00 m (Preferred) Top and Bottom of Ramp 1.80 m (Level Area)
Surface Continuous, 6.5 mm (Max.) High Enough to be felt by shoe sole Handrails Both Sides @ 0.70 m and 0.90 m
Tactile Blocks / Surface Low enough not to cause tripping or
Spaces affect mobility of wheelchairs Curbs 0.10 m (Both Sides)
1.50 m (Min. Dimension)
(Busy / Lengthy
12.00 m (Max. Length)
Walkways Light Controlled Crossing having Rise >0.20 m (To Vehicular Traffic)
Most Beneficial Form Railing
Pedestrian Phases 1.80 m across the full width at lower end
To Guide the Blind Straightforward routes with Right Angle Turns
Synchronized Audible Signals
Headroom 2.0 m (Min.) , preferably higher (prolonged, distinguished, by TEC) THRESHOLDS
OPEN SPACES Flashing Green Period Based on 0.90 m/sec (Not 1.20 m/s) Maximum Height 25 mm, Ramped (Preferred)
advice must be unprejudiced; he is Control Panels 0.90 m to 1.20 m (H) 1.50 m X 1.50 m (Before & Beyond)
Clear Level Space
charged with the exercise of judicial Button Controls 20 mm Ø; 1 mm (D) with Braille-Type Signs 1.20 m if not into a corridor
functions as between client and
SAFETY Out-Swinging Doors Storage Rooms, Closets, Accessible Restrooms
contractor and must act with
FENCING FOR ROADWORKS & FOOTWORKS Door Knobs / Hardware 0.82m to 1.06 m; 0.90 m (Preferred)
entire impartiality; he has
Height (Top of Rail) 1.00 m above adjacent surface Vertical Pull Handles 1.06 m OC (Preferred)
moral responsibilities to his
Tapping Rail 0.35 m above adjacent surface Kick Plates 0.30 m to 0.40 m
professional associates and
subordinates; and he is engaged in a NO GAPS between adjoining fence lengths, STRONG enough resistance CORRIDORS
profession which carries with it grave COVERS FOR EXCAVATIONS Width (Clear) 1.20 m
Should not reduce the footway width to less than 1.20 m Turning Space 2.25 m2; 1.50 m (Min. Dimension)
EMERGENCY EXIT Number 1 / 20 WC; 2 / >20 WC
AUDIBLE & VISIBLE ALARM SYSTEM Water Closet 0.45 m (H); Flush Control @ 1.20 m (H)
Audio-Visual Alarm In all fire sections as per (PD1185) 0.80 m Height (Max.)
Lavatories 0.60 to 0.70 m Knee Recess Vertical Clearance
Vibra-Alarms Deaf or Hearing Impaired Occupants 0.50 m Depth
NOTHING FOLLOWS Urinals Elongated or Through Lip of 0.48 m (H)
NEIGHBORHOOD STRUCTURE AND ELEMENTS
FRONTAGE TYPES :
WIND EXPOSURE CATEGORY
EXPOSURE DESCRIPTION