Booster Regulator/Air Tank New

Increase factory air pressure by up to 4 times! RoHS


Air-only operation requires no power supply,
reduces heat generation, and
Boost pressure
allows easy installation. Heavy

NEW
0.3 MPa 0.6 MPa
Renewed model with
Factory line
pressure increase ratio
2 to 4 times (VBA11A)
Booster Regulator + Air Tank
0.3 MPa
0.3 MPa

Light

Compressor
0.3 MPa
Light

No power supply or wiring needed Easy installation


There is no need to Simply insert the unit
install dedicated in the air line.
electrical wiring. Requires far less
space than installing
the compressor.

Low heat generation Air-only operation


Very little heat is Operation is safe
generated because because no
no electricity is electricity is used.
used, and there is
no impact on
cylinders, solenoid
valves, etc.

Booster Regulator/Series VBA Air Tank/Series VBAT

Series VBA/VBAT
CAT.ES11-96D
Booster Regulator Series VBA

Improved Doubled
service life that of the conventional model
Reduced
noise
Reduced by 13dB (A)
compared with the conventional model
• Floating piston structure (PAT. PEND) • Metal noise reduced by a bumper on the impact part
• Grease retaining groove∗ of the switch valve
∗ Except VBA10A, 11A • Exhaust noise
Grease reduced by a high-
retaining
groove
noise reduction
silencer
Switching valve

Floating structure Bumper

Improved reliability Anti-condensation

Built-in mesh filter at IN port Integrated air-feeding tube with the


• Prevents operation failure due to foreign matter. main tube Cylinder tube
• Mitigates condensation Tie-rod guide
Mesh filter
caused by cooling during
exhaust expansion.
Air-feeding tube

VBA20A

VBA40A
NEW
Elbow silencer added∗ (Option) 1/8" gauge ports

Space saving when installed has • Allows use of standard fittings for remote
pressure monitoring, etc.
been realized. ∗ Gauge ports changed from 1/16" to 1/8" (VBA1lA, 2lA)
Elbow silencer
∗ Except VBA2lA, 4lA

Gauge port
VBA10A

Air-operated type Max. operating pressure 1.6 MPa Fourfold pressure


increase type
NEW

VBA22A

VBA11A
VBA43A

VBA42A
Features 1
P. 1
Pressure increase ratio Twice 2 to 4 times
Handle-operated type Air-operated type Handle-operated type
Operation (Direct operation) (Remote operation) (Direct operation)
Set pressure
range
0.2 to 1.0 MPa 0.2 to 1.6 MPa 0.2 to 1.0 MPa 0.2 to 2.0 MPa
Body size (2.0 MPa)

VBA10A-02 VBA11A-02
(0.2 to 2.0 MPa)

1/4"

VBA20A-03 VBA22A-03

3/8"

VBA40A-04 VBA43A-04 VBA42A-04


(0.2 to 1.6 MPa)

1/2"

Air Tank Series VBAT P. 12


Perfect fit with a booster regulator
This is an air tank to which a booster regulator can be connected
compactly. It can be used alone as a tank. The pressure vessel law is
different from country to country, so as an air tank suitable to a
country needs to be confirmed.

Extensive product lineup


To meet a variety of usage environment and pressure specifications,
models are available in two materials, stainless steel 304 and carbon
steel (SS400), and in four sizes ranging from 5 liters to 38 liters.

Model VBAT05A VBAT10A VBAT20A VBAT38A


Tank capacity (L) 5 10 20 38
Max. operating pressure (MPa) 2.0 1.0
Material Carbon steel

Model VBAT05S VBAT10S VBAT20S VBAT38S


Tank capacity (L) 5 10 20 38 Caution
Max. operating pressure (MPa) 2.0 When used as a single unit (not connected with a booster regulator) and
Material Stainless steel pressurized at over 1 MPa at normal temperatures, the air tank falls
under the scope of the “High Pressure Gas Safety Act” in Japan.
Features 2
Booster Regulator

Series VBA RoHS

Made to Order
How to Order (For details, refer to page 11.)

VBA 40A 04
Body size Semi-standard
10A 1/4", Handle-operated type Symbol Semi-standard
20A 3/8", Handle-operated type Nil Standard product
40A 1/2", Handle-operated type Pressure increase Pressure unit on the product name
Z Note) label and pressure gauge: psi
22A 3/8", Air-operated type ratio: Twice
Note) Thread type: NPT, NPTF
42A 1/2", Air-operated type
Under the new measurement law, the pressure
43A 1/2", Max. operating pressure 1.6 MPa unit of “psi” on the pressure gauges cannot be
Pressure increase used in Japan.
11A 1/4", Handle-operated type
ratio: 2 to 4 times Option
Note) Symbol Option
Thread type
Nil None
Symbol Thread type
Nil
G Pressure gauge
Symbol Rc
N Silencer
F G
S High-noise reduction silencer Note)
N NPT
GN Pressure gauge, Silencer
T NPTF
GS Pressure gauge, High-noise reduction silencer Note)
Note) Thread types apply to the IN, OUT,
and EXH ports of the VBA1lA and to LN Elbow silencer Note)
the IN, OUT, EXH, and gauge ports of LS Elbow high-noise reduction silencer Note)
the VBA2lA and VBA4lA. GLN Pressure gauge, Elbow silencer Note)
The gauge ports of the VBA1lA are GLS Pressure gauge, Elbow high-noise reduction silencer Note)
Rc thread type regardless of the
thread type indication. Note) Refer to “Combination of Thread Type and Options.”

Port size Pressure Pressure


gauge gauge
VBA10A-02 Symbol Port size Applicable series
VBA11A-02 02 1/4 VBA1lA
03 3/8 VBA2lA
04 1/2 VBA4lA

Silencer Elbow silencer

Combination of Thread Type and Options


VBA20A-03 Thread Option Semi-standard
Body size
type Nil G N S GN GS LN LS GLN GLS Nil -Z
Nil P P P P P P P P P P P —
10A F P P P P P P P P P P P —
11A N P P P — P — P — P — P P
VBA22A-03
T P P P — P — P — P — P P
Nil P P P P P P P —
20A F P P P P P P P —
22A N P P P P P P P P
T P P P P P P P P
Nil P P P P P P P —
40A
F P P P P P P P —
42A
N P P P P P P P P
43A
T P P P P P P P P
VBA40A-04 Air Tank Compatibility Chart
Booster
regulator
VBA1lA VBA2lA VBA4lA
Air tank
VBAT05A
P — —
VBAT05S
VBAT10A
P P —
VBAT10S
VBAT20A — P P
VBA42A-04 VBAT20S
VBAT38A
VBA43A-04 — P P
VBAT38S

1
Booster Regulator Series VBA

Standard Specifications
Model VBA10A-02 VBA20A-03 VBA40A-04 VBA22A-03 VBA42A-04 VBA43A-04 VBA11A-02
Fluid Compressed air
Pressure increase ratio Twice 2 to 4 times
Handle-operated with
Pressure adjustment mechanism Handle-operated with relief mechanism Note 1) Air-operated
relief mechanism Note 1)
Max. flow rate Note 2) (L/min (ANR)) 230 1000 1900 1000 1900 1600 70
Set pressure range (MPa) 0.2 to 2.0 0.2 to 1.0 0.2 to 1.0 0.2 to 1.6 0.2 to 2.0
Supply pressure range (MPa) 0.1 to 1.0
Proof pressure (MPa) 3 1.5 2.4 3
Port size (Rc)
1/4 3/8 1/2 3/8 1/2 1/4
(IN/OUT/EXH: 3 locations)
Pressure gauge port size (Rc)
1/8
(IN/OUT: 2 locations)
Ambient and fluid temperature (°C) 2 to 50 (No freezing)
Installation Horizontal
Lubrication Grease (Non-lube)
Weight (kg) 0.84 3.9 8.6 3.9 8.6 8.6 0.89
Note 1) If the OUT pressure is higher than the set pressure by the handle, excess pressure is exhausted from the back of the handle.
Note 2) Flow rate at IN= OUT= 0.5 MPa. The pressure varies depending on the operating conditions. Refer to “Flow-rate Characteristics” on pages 3 and 4.

Options/Part No.
Pressure Gauge, Silencer (When thread type is Rc or G.)
Model VBA10A-02 VBA20A-03 VBA40A-04 VBA22A-03 VBA42A-04 VBA43A-04 VBA11A-02
Description VBA10A-F02 VBA20A-F03 VBA40A-F04 VBA22A-F03 VBA42A-F04 VBA43A-F04 VBA11A-F02
Pressure gauge G G27-20-01 G36-10-01 KT-VBA22A-7 G36-10-01 G27-20-01 G27-20-01
Silencer N AN200-02 AN300-03 AN400-04 AN300-03 AN400-04 AN400-04 AN200-02
High-noise reduction silencer S ANA1-02 ANA1-03 ANA1-04 ANA1-03 ANA1-04 ANA1-04 ANA1-02
Elbow for silencer L KT-VBA10A-18 — — — — — KT-VBA10A-18
Note 1) In the case of options GN, two pressure gauges and one silencer are included in the same container as accessories.
Note 2) KT-VBA22A-7 is a pressure gauge with fitting. (Please order two units when using with IN and OUT.)

Pressure Gauge, Silencer (When thread type is NPT or NPTF.)


Model VBA10A-N02∗ VBA20A-N03∗ VBA40A-N04∗ VBA22A-N03∗ VBA42A-N04∗ VBA43A-N04∗ VBA11A-N02∗
VBA10A-T02∗ VBA20A-T03∗ VBA40A-T04∗ VBA22A-T03∗ VBA42A-T04∗ VBA43A-T04∗ VBA11A-T02∗
Description ∗: when “-Z” ∗: when “-Z” ∗: when “-Z” ∗: when “-Z” ∗: when “-Z” ∗: when “-Z” ∗: when “-Z”
Pressure gauge ∗: when Nil G27-20-01 G36-10-N01 KT-VBA22A-7N G36-10-N01 G27-20-N01 G27-20-01
G
Pressure gauge ∗: when “-Z” Note 4) G27-P20-01 G36-P10-N01 KT-VBA22A-8N G36-P10-N01 G27-P20-N01 G27-P20-01
Silencer N AN200-N02 AN300-N03 AN400-N04 AN300-N03 AN400-N04 AN400-N04 AN200-N02
High-noise reduction silencer S — ANA1-N03 ANA1-N04 ANA1-N03 ANA1-N04 ANA1-N04 —
Elbow for silencer L KT-VBA10A-18N — — — — — KT-VBA10A-18N
Note 1) In the case of options GN, two pressure gauges and one silencer are included in the same container as accessories.
Note 2) KT-VBA22A-7N, KT-VBA22A-8N are pressure gauges with fittings. (Please order two units when using with IN and OUT.)
Note 3) Under the new measurement law, the pressure unit of “psi” on the pressure gauges cannot be used in Japan.
Note 4) Pressure unit on the pressure gauge: psi

Related Products/Part No. Design


Mist Separator, Exhaust Cleaner Caution
Model For VBA40A-04 1. System configuration
For VBA10A-02 For VBA20A-03
For VBA42A-04 • The IN port of the booster regulator has metallic mesh to prevent
For VBA11A-02 For VBA22A-03
Description For VBA43A-04 dust from entering the booster regulator. However, it cannot
Mist separator AM250C-02 AM450C-04, 06 AM550C-06, 10 remove dust continuously or separate drainage. Make sure to
Exhaust cleaner AMC310-03 AMC510-06 AMC610-10 install a mist separator (AM series) on the inlet side of the
Note) Refer to page 12 for air tanks, Best Pneumatics No. 5 for mist separators
booster regulator.
and Best Pneumatics No. 6 for exhaust cleaners. • The booster regulator has a sliding part inside, and it generates
Refer to the separate operation manual for the connection method. dust. Also, install an air purification device such as an air filter or
a mist separator on the outlet side as necessary.
• Connect a lubricator to the outlet side, because the accumulated
oil in the booster regulator may result in a malfunction.
2. Exhaust air measures
• Provide a dedicated pipe to release the exhaust air from each
booster regulator. If exhaust air is converged into a pipe, the
back pressure that is created could cause improper operation.
• Depending on the necessity, install a silencer or an exhaust
cleaner on the exhaust port of the booster regulator to reduce
the exhaust noise.
3. Maintenance space
• Allow the sufficient space for maintenance and inspection.
2
Series VBA

VBA10A VBA20A, 22A VBA40A, 42A

Flow-rate Characteristics Flow-rate Characteristics Flow-rate Characteristics


2 1.0 1.0
P1
=1
.0
MP 0.8 0.8
Outlet pressure (MPa)

Outlet pressure (MPa)

Outlet pressure (MPa)


1.5 a
P1 P1 = 0.5 MPa
=0
.75
MP 0.6 0.6
a
1 P1
=0 P1 = 0.5 MPa
P1 .5 0.4 0.4
=0 MP
.4 a P1 = 0.4 MPa
P1 MP P1 = P2
=0 a P1 = 0.4 MPa
0.5 .3 P1 = 0.3 MPa
MP P1 = 0.3 MPa
a 0.2 0.2

0 100 200 300 400 0 200 400 600 800 1000 1200 0 500 1000 1500 2000
Outlet air flow rate (L/min (ANR)) Outlet air flow rate (L/min (ANR)) Outlet air flow rate (L/min (ANR))

Pressure Inlet pressure: 0.7 MPa


Outlet pressure: 1.0 MPa
(Representative Pressure Inlet pressure: 0.7 MPa
Outlet pressure: 1.0 MPa
(Representative Pressure Inlet pressure: 0.7 MPa
Outlet pressure: 1.0 MPa
(Representative
Characteristics Flow rate: 20 L/min (ANR)
value) Characteristics Flow rate: 20 L/min (ANR)
value) Characteristics Flow rate: 20 L/min (ANR)
value)

1.1 1.04 1.04

1.05 Set point


1.02 Set point 1.02 Set point
Outlet pressure (MPa)

Outlet pressure (MPa)

Outlet pressure (MPa)


1.0
1.0 1.0
0.95
0.98 0.98
0.9
0.96 0.96
0.85

0.8 0.94 0.94

0 0.4 0.5 0.6 0.7 0.8 0.9 1 0 0.4 0.5 0.6 0.7 0.8 0.9 1 0 0.4 0.5 0.6 0.7 0.8 0.9 1
Inlet pressure (MPa) Inlet pressure (MPa) Inlet pressure (MPa)

Charge Characteristics Charge Characteristics Charge Characteristics


60 12 5
11
50 10
Charge time per 10 L t (s)

Charge time per 10 L t (s)

Charge time per 10 L t (s)

4
9
40 8
7 3
30 6
5 2
20 4
3
1
10 2
1
0 0 0
1.0 1.2 1.4 1.6 1.8 2.0 1.0 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2.0 1.0 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2.0
Pressure increase ratio P2/P1 Pressure increase ratio P2/P1 Pressure increase ratio P2/P1

VBA10A VBA20A, 22A VBA40A, 42A


P The time required to charge pressure in the P The time required to charge pressure in the P The time required to charge pressure in the
tank from 0.7 MPa to 0.95 MPa at 0.5 MPa tank from 0.8 MPa to 1.0 MPa at 0.5 MPa tank from 0.8 MPa to 1.0 MPa at 0.5 MPa
supply pressure: supply pressure: supply pressure:
P2 0.7 P2 0.95 P2 0.8 P2 1.0 P2 0.8 P2 1.0
= = 1.4 = = 1.9 = = 1.6 = = 2.0 = = 1.6 = = 2.0
P1 0.5 P1 0.5 P1 0.5 P1 0.5 P1 0.5 P1 0.5
With the pressure increase ratio from 1.4 to 1.9, With the pressure increase ratio from 1.6 to 2.0, With the pressure increase ratio from 1.6 to 2.0,
the charge time of 23 – 6 = 17 sec. (t) is given the charge time of 11.5 – 3.8 = 7.7 sec. (t) is the charge time of 3.5 – 1.1 = 2.4 sec. (t) is given
by the graph. Then, the charge time (T) for a given by the graph. Then, the charge time (T) by the graph. Then, the charge time (T) for a
10 L tank: for a 100 L tank: 100 L tank:
V 10 V 100 V 100
T=tx = 17 x = 17 (s). T=tx = 7.7 x = 77 (s). T=tx = 2.4 x = 24 (s).
10 10 10 10 10 10

3
Booster Regulator Series VBA

VBA43A VBA11A Pulsation/Pulsation is decreased with a tank.


If the outlet capacity is undersized, pulsation may
occur.
Flow-rate Characteristics Flow-rate Characteristics

1.6
2 VBAT05A
0.1
1.4
Outlet pressure (MPa)

Outlet pressure (MPa)

P1

Max. pulsation range (MPa)


1.2 P1

=
=0 0.08

1.
P1
P1 .8

0
=0 MP

=
1

M
P1

Pa
.7

0.
P1 =0 a
MP

75
P1
= .6 a 1

M
0.8 0. MP 0.06

=0
P1
5

Pa
MP a

P1

.5
=0
a P1 = P2

MP
=0
0.6

.4
P1 = P2

MP
.3

a
0.04

a
0.4

Pa
0.2
0.02
VBAT05A
0 500 1000 1500 2000 2500 3000 0 50 100 150
Outlet air flow rate (L/min (ANR)) Outlet air flow rate (L/min (ANR))
0 1 2 3 4 5
Pressure Inlet pressure: 0.7 MPa
Outlet pressure: 1.0 MPa
(Representative Pressure Inlet pressure: 0.6 MPa
Outlet pressure: 2.0 MPa
(Representative Capacity (L)
Characteristics Flow rate: 20 L/min (ANR)
value) Characteristics Flow rate: 10 L/min (ANR)
value)
VBAT
1.08 2.1
Set point
1.06 2.05
VBA1lA
Outlet pressure (MPa)

Outlet pressure (MPa)

1.04
Set point 2.0
1.02
1.95
VBAT10A, 20A, 38A
1.0 0.1
1.9
0.98

Max. pulsation range (MPa)


1.85 0.08
0.96

0.94 1.8
0.06

0 0.4 0.5 0.6 0.7 0.8 0.9 1 0 0.4 0.5 0.6 0.7 0.8 0.9 1 VBAT10A
Inlet pressure (MPa) Inlet pressure (MPa) 0.04

Charge Characteristics Charge Characteristics 0.02


VBAT20A
VBAT38A
5 400
0 10 20 30 38 40
Capacity (L)
Charge time per 10 L t (s)

Charge time per 10 L t (s)

4
300
VBAT
3

200
VBA2lA
2
VBA4lA

100 Conditions:
1 Inlet pressure: 0.5 MPa
Outlet set pressure: 1 MPa
Flow rate: Between 0 and max. flow rate
0 0
1.0 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2.0
Pressure increase ratio P2/P1
1.0 2.0
Pressure increase ratio P2/P1
3.0 4.0
• Performance of air tank
• Alleviates the pulsation generated on the
outlet side.
VBA43A VBA11A
• When air consumption exceeds air supply
P The time required to charge pressure in the P The time required to charge pressure in the during intermittent operation, required air
tank from 0.8 MPa to 1.0 MPa at 0.5 MPa tank from 1.0 MPa to 1.5 MPa at 0.5 MPa will be accumulated in the tank for use.
supply pressure: supply pressure: This does not apply for continuous
P2 0.8 P2 1.0 P2 1.0 P2 1.5 operation.
= = 1.6 = = 2.0 = = 2.0 = = 3.0
P1 0.5 P1 0.5 P1 0.5 P1 0.5
With the pressure increase ratio from 1.6 to 2.0, With the pressure increase ratio from 2.0 to 3.0,
the charge time of 4.5 – 1.3 = 3.2 sec. (t) is the charge time of 147 – 58 = 89 sec. (t) is
given by the graph. Then, the charge time (T) given by the graph. Then, the charge time (T)
for a 100 L tank: for a 10 L tank:
V 100 V 10
T=tx = 3.2 x = 32 (s). T=tx = 89 x = 89 (s).
10 10 10 10

4
Series VBA

Sizing ( Sizing can be achieved with the SMC Pneumatic System Energy Saving Program Ver. 3.1
which can be downloaded from the SMC website: http://www.smcworld.com/ )
Tc Ts

Stroke
L
P1 P3 P2

øD Upper limit of pressure inside the tank P3

Pressure
Necessary supply
pressure to cylinder P2
Lower limit of pressure inside the tank P2
Inlet pressure P1

START Time
Necessary conditions: Example Other conditions:
D [mm]: Cylinder bore size 100 Q [L/min (ANR)]: Required air flow rate
L [mm]: Cylinder stroke 100 Qb [L/min (ANR)]: Outlet air flow rate of booster regulator
W [mm/s]: Cylinder operating speed Tc [s]: Cylinder operating time
200
C [pc.]: Number of cylinders K: Cylinder double-acting: 2, single-acting: 1
1
Tc [s]: Cylinder operating time P3 [MPa] Note 2): Tank charge pressure
Provide requisite Ts [s]: Cylinder stop time 0.5 T1 [s]: Time to charge (Time to charge to P2)
conditions for P1 [MPa]: Inlet pressure 30 T2 [s]: Time to charge (Time to charge to P3)
selection. P2 [MPa] Note 1): Necessary supply 0.5 T [s]: Time to charge (Time to charge from P2 to P3)
pressure to cylinder 0.8 Z: Number of booster regulators
Note 1) P2 is the necessary supply pressure to a cylinder, and set the pressure below the lower limit of pressure inside the tank
with a regulator. Adjust the pressure taking the maximum operating pressure of equipment in use into consideration.
Note 2) P3 is the output pressure of the booster regulator, which is also the upper limit of charge pressure to the tank.

π x D2 x W (P2 + 0.101)
Caution
Q [L/min (ANR)] = x x 60 x C
4 x 106 0.101 • Use the VBA11A (pressure increase ratio 4) with pressure
Calculate required increase ratio 2 to 4. Usage of pressure increase ratio below 2
air flow rate Q. π x 1002 x 200 (0.8 + 0.101) is preferred for the VBA10A (pressure increase ratio 2).
Q= x x 60 x 1 = 841 [L/min (ANR)]
4 x 106 0.101 A stable operation and increased life expectancy will result.
• Inlet supply pressure volume is {approximately twice (pressure
increase ratio 2), approx. 4 times (pressure increase ratio 4)}
Select booster regulator VBA2lA: Qb = 600 [L/min (ANR)] the volume of the outlet side. Booster regulator requires the
size from flow-rate VBA4lA: Qb = 1050 [L/min (ANR)] inlet side volume which is the sum of the flow volume running
characteristics table. Refer to “Flow-rate Characteristics” on pages 3 and 4. into the outlet side and the volume exhausted from E port (for
driving), because air is the power source.

NO: Need no tank The VBA4lA can supply necessary pressure.


Avoid
pulsation. NO
Judgement of
flow rate (Max. 0.05
MPa)

YES The VBA2lA cannot obtain necessary pressure. YES

(Q – Qb/2) x (Tc x K/60) Select the tank


V [L] =
(P3 – P2) x 9.9 from table below.
Obtain the tank
capacity V.
(841 – 600/2) x (0.5 x 2/60)
V= = 4.6 [L] Tank model Internal capacity Applicable combination model
(1.0 – 0.8) x 9.9
VBAT05l 5L VBA1lA — —
VBAT10l 10 L VBA1lA VBA2lA —
Select the tank Select the VBAT10l, which can be
directly connected to the VBA2lA. VBAT20l 20 L — VBA2lA VBA4lA
capacity over V.
VBAT38l 38 L — VBA2lA VBA4lA

Refer to “Charge Characteristics” on pages 3 and 4.


Calculate time T from
charge characteristics T [s] = ( V ) x T2 – T1
10 Z
table.

4.6 11.5 – 3.8


T=( )x = 3.5 [s]
10 1

Extend
Judgement NO stop time Ts NO Increase number of
of charge time up to charge time booster regulators (Z)
T ≤ Ts T or more. to decrease T.

YES YES YES

When running continuously for longer periods of time, confirm the life expectancy.
When the life expectancy is shorter than required, select a larger sized booster regulator.
END
5
Booster Regulator Series VBA

Working Principle

The IN air passes through the check valve to booster chambers A and B. Meanwhile, air is supplied to drive chamber B via the governor and
the switching valve. Then, the air pressure from drive chamber B and booster chamber A are applied to the piston, boosting the air in booster
chamber B. As the piston travels, the boosted air is pushed via the check valve to the OUT side. When the piston reaches to the end, the piston
causes the switching valve to switch, so that drive chamber B is in the exhaust state and drive chamber A is in the supply state respectively.
Then, the piston reverses its movement, this time, the pressures from booster chamber B and drive chamber A boosts the air in booster
chamber A and sends it to the OUT side. The process described above is repeated to continuously supply highly pressurized air from the IN to
the OUT side. The governor establishes the outlet pressure by handle operation and pressure adjustment in the drive chamber by feeding back
the outlet pressure.
Air-operated type
VBA10A, 20A, 40A, 43A Pilot pressure VBA11A
Drive Governor Governor Drive
chamber A chamber A
Booster Drive
chamber A chamber B
IN (Inlet) IN (Inlet)
Drive chamber B
VBA22A, 42A
Piston rod Piston rod
Booster
chamber A
Piston
Piston

Check valve Booster chamber B Booster Check valve


Switching valve chamber B Switching valve
E OUT (Outlet) OUT (Outlet) E

Circuit Example
• When only some of the machines in the plant require high-pressure • When the actuator output is insufficient but space limitations prohibit
air, booster regulators can be installed for only the equipment that switching to a larger cylinder diameter, a booster regulator can be
requires it. This allows the overall system to use low-pressure air used to increase the pressure. This makes it possible to boost the
while accommodating machines requiring high-pressure air. output without replacing the actuator.
General line (low pressure) Locations requiring high pressure • When a certain level of output is required but the cylinder size must
be kept small so that the driver remains compact.
VBA
Plant line (source pressure)

VBA VBA (Two-stage ø80


pressure boost)
ø100

OUT 0.8 MPa E

0.5 MPa
IN 0.5 MPa
Operating pressure: Operating pressure:
VBA 0.5 MPa Equivalent 0.8 MPa
Bore size: ø100 output Bore size: ø80
Output ≈ 3850 N Output ≈ 4000 N
• When charging a tank or the like from a source at atmospheric
pressure, a circuit with a check valve can be used to reduce the
charge time by allowing air to pass through the check valve up to • When only one side of the cylinder is used for work, booster
the inlet pressure. regulators can be installed only on the lines that require them to
reduce the overall air consumption volume.
P1
P2

Initially, inlet pressure (P1) passes through the check valve, fills P2,
and results in P1 = P2.
Outlet pressure (MPa)

Shortening time

P2

P1

Without check
valve by-pass

0 Time t (S)

6
Series VBA

Design Mounting

Warning Caution
1. Warning concerning abnormal outlet pressure 1. Transporting
• If there is a likelihood of causing an outlet pressure drop • When transporting this product, hold it lengthwise with both
due to unforeseen circumstances such as equipment hands. Never hold it by the black handle that protrudes from
malfunction, thus leading to a major problem, take safety the center because the handle could become detached
measures on the system side. from the body, causing the body to fall and leading to injury.
• Because the outlet pressure could exceed its set range if
there is a large fluctuation in the inlet pressure, leading to 2. Installation
unexpected accidents, take safety measures against abnor- • Install this product so that the silver-colored tie-rods and
mal pressures. cover are placed horizontally. If mounted vertically, it may
• Operate the equipment within its maximum operating result in a malfunction.
pressure and set pressure range. • Because the piston cycle vibration is transferred, use the
following mounting bolts (VBA1: M5; VBA2, 4: M10) and
2. Residual pressure measures tighten them with the specified torque (VBA1: 3 N·m; VBA2,
• Connect a 3-port valve to the OUT side of the booster 4: 24 N·m).
regulator if the residual pressure must be released quickly • If the transmission of vibration is not preferred, insert an
from the outlet pressure side for maintenance, etc. (Refer to isolating rubber material before installation.
the diagram below.) The residual outlet pressure side • Mount the pressure gauge with a torque of 7 to 9 N·m.
cannot be released even if the 3-port valve is connected to
the IN side because the check valve in the booster regulator
will activate. Piping

Caution
1. Flushing
• Use an air blower to flush the piping to thoroughly remove
any cutting chips, cutting oil, or debris from the piping
• After operation is finished, release the supply pressure at
inside, before connecting them. If they enter the inside of
the inlet. This stops the booster regulator from moving
the booster regulator, they could cause the booster regula-
needlessly and prevents operating malfunctions.
tor to malfunction or its durability could be affected.
2. Piping size
• To bring the booster regulator’s ability into full play, make
sure to match the piping size to the port size.

Air Supply
Selection
Caution
Caution 1. Quality of air source
1. Check the specifications. • Connect a mist separator to the inlet side near the booster
• Consider the operating conditions and operate this product regulator. If the quality of the compressed air is not
within the specification range that is described in this thoroughly controlled, the booster regulator could malfunc-
catalog. tion (without being able to boost) or its durability could be
affected.
2. Selection • If dry air (atmospheric pressure dew point: –17°C or less) is
• Based on the conditions (such as pressure, flow rate, takt
used, the life expectancy may be shortened because dry air
time) required for the outlet side of the booster regulator,
select the size of the booster regulator in accordance with will accelerate evaporation of grease inside.
the selection procedures described in this catalog or model
selection program.
• Use the VBA11A (pressure increase ratio 4) with pressure Operating Environment
increase ratio 2 to 4. Usage of pressure increase ratio
below 2 is preferred for the VBA10A (pressure increase
ratio 2). A stable operation and increased life expectancy
Caution
will result. 1. Installation location
• Inlet supply pressure volume is {approximately twice • Do not install this product in an area that is exposed to
(pressure increase ratio 2), approx. 4 times (pressure rainwater or direct sunlight.
increase ratio 4)} the volume of the outlet side. Booster • Do not install in locations influenced by vibrations. If it must
regulator requires the inlet side volume which is the sum of be used in such an area due to unavoidable circumstances,
the flow volume running into the outlet side and the volume please contact SMC beforehand.
exhausted from E port (for driving), because air is the power
source.
• When running continuously for longer periods of time,
confirm the life expectancy. The life expectancy of a booster
regulator is dependent upon the operational cycle. Thus,
when used for driving cylinders, etc. in the outlet side, life
expectancy will be reduced.
• Make sure the outlet pressure is set 0.1 MPa or higher than
the inlet pressure. A pressure difference below 0.1 MPa
makes the operation unstable and may result in a malfunc-
tion.
7
Booster Regulator Series VBA

Handling

Caution
1. Setting the pressure on the handle-operated type 3. Draining
• If air is supplied to the product in the shipped state, the air • If this product is used with a large amount of drainage
will be released. accumulated in the filter, mist separator or tank, the
Set the pressure by quickly pulling up on the governor drainage could flow out, leading to equipment malfunction.
handle, releasing the lock, and rotating the handle in the Therefore, drain the system once a day. If it is equipped
direction of the arrow (+). with an auto drain, check its operation once a day.
• There is an upper and lower limit for the handle rotation. If
over-rotating the handle even after reaching to the limit, the
4. Exhaust
• Exhausting time from E port may be longer for a booster
internal parts may be damaged. If the handle suddenly feels
regulator which is set to switch in longer hour intervals. This
heavy while being turned, stop turning the handle.
is not an abnormal phenomenon.
• Once the setting is completed, push the handle down and
lock it. 5. Maintenance
• To decrease the outlet pressure, after the pressure has • Life expectancy varies depending on the quality of air and
been set, rotate the handle in the direction of the arrow (–). the operating conditions. Signs that the unit is reaching the
The residual air will be released from the area of the end of its service life include the following:
handle, due to the relief construction of the governor. • Constant bleed from under the handle.
• To reset the pressure, first reduce the pressure so that it is • Air exhaust noise can be heard from the booster regulator
lower than the desired pressure; then, set it to the desired at 10 to 20 second intervals even when there is no air
pressure. consumption on the outlet side.
Conduct maintenance earlier than scheduled in such cases.
• When maintenance is required, confirm the model and serial
SMC number of the booster regulator, and please contact SMC
Low High
for maintenance kit.
• Conduct maintenance according to the specified mainte-
nance procedure by individuals possessing enough knowl-
2. Setting the pressure on the air-operated type edge and experiences in maintaining pneumatic equipment.
(VBA22A, 42A) • The list of replacement parts and kit number are shown on
• Connect the outlet pipe of the pilot regulator for the remote page 9, and the figure shows the position of the parts.
control to the pilot port (P). (Refer to the diagram below.)
• Refer to the graph below for the relationship between the
pilot pressure and outlet pressure.
• The AR20 and AW20 are recommended for the pilot regula-
tor.

Pilot regulator

• The outlet pressure is twice the pilot pressure.


• When the inlet pressure is 0.4 MPa:
Pilot pressure 1
0.2 MPa to 0.4 MPa 0.9
Outlet pressure 0.8
Outlet pressure MPa (Q = 0)

0.4 MPa to 0.8 MPa


0.7

0.6

0.5

0.4

0.3

0.2

0.1

0
0.1 0.2 0.3 0.4 0.5
Pilot pressure MPa

8
Series VBA

Construction/Replacement Parts
VBA10A VBA11A

q r e w t u r e w t q

VBA20A, 22A,
VBA40A, 42A, 43A Air-operated type
q

t q y r w e

VBA22A, 42A

Replacement Parts/Kit No.


Place an order with the following applicable kit number.
Model VBA10A VBA20A VBA40A VBA22A VBA42A VBA43A VBA11A
Kit no. KT-VBA10A-1 KT-VBA20A-1 KT-VBA40A-1 KT-VBA22A-1 KT-VBA42A-1 KT-VBA43A-1 KT-VBA11A-20

The kit includes the parts from q to u and a grease pack.


Model VBA10A VBA20A VBA40A VBA22A VBA42A VBA43A VBA11A
No.
Description Quantity
1 Piston seal 2 2 large 1 small 2 1 each large and small
2 Governor assembly 1
3 Check valve 4 2
4 Gasket 2
5 Rod seal 1
6 Mounting screw — 8 12 8 12 —
7 Cover C assembly — 1
— Grease pack 1 2 1 2 1
∗ The grease pack has 10 g of grease.
∗ Make sure to refer to the procedure for maintenance.

9
Booster Regulator Series VBA

Dimensions
VBA10A-02 With elbow silencer (Option)
150
Pressure gauge (Option) Elbow silencer (Option)
60
IN side OUT side
gauge port gauge port 7 28 7 28
Rc 1/8 Rc 1/8
Silencer
(Option)

113

113
IN port IN port
Rc 1/4 Rc 1/4

23

23
OUT port OUT port
Rc 1/4 Rc 1/4

27

27
22

22
40 4 x ø5.5 60 EXH port 4 x ø5.5 60
8.5

50 70 Rc 1/4 70
(When silencer installed: 125) (97)
(When high-noise reduction EXH port
silencer installed: 126)
Rc 1/4
VBA11A-02 With elbow silencer (Option)
150
Pressure gauge (Option)
33 30 Elbow silencer (Option)
IN side OUT side
gauge port gauge port 7 28 7 28
Rc 1/8 Rc 1/8
Silencer
(Option)
113

113
IN port IN port
Rc 1/4 Rc 1/4
23

23
OUT port OUT port
Rc 1/4 Rc 1/4
27

27
22

22
40 4 x ø5.5 60 EXH port 4 x ø5.5 60
8.5

50 70 Rc 1/4 70
(When silencer installed: 125) (97)
(When high-noise reduction EXH port
VBA20A-03 silencer installed: 126) Rc 1/4
300
39
Pressure gauge (Option)
28
IN side gauge port OUT side gauge port
Rc 1/8 Rc 1/8

IN port
176

Rc 3/8
43

15 Silencer (Option)
OUT port
Rc 3/8
46

21
24

53 98 EXH port
3.2

4 x ø12
73 118 Rc 3/8
(When silencer installed: 179)
VBA40A-04 (When high-noise reduction
404 silencer installed: 179)
40
Pressure gauge (Option)
43
IN side gauge port OUT side gauge port
Rc 1/8 Rc 1/8

IN port
Rc 1/2
215
62

8
OUT port Silencer (Option)
Rc 1/2
22
62.8

32

130
3.2

96 EXH port
4 x ø12
150 Rc 1/2
116
(When silencer installed: 224)
(When high-noise reduction
silencer installed: 230)
10
Series VBA

Dimensions
VBA22A-03 300
28
39 Pressure gauge (Option)

IN side gauge port OUT side gauge port


Rc 1/8 Rc 1/8

IN port
Rc 3/8

139
43
15
OUT port Silencer (Option)
Rc 3/8
21

46

24
53 98 EXH port
3.2

4 x ø12
73 118 Rc 3/8

(When silencer installed: 179)


VBA42A-04 404
(When high-noise reduction
silencer installed: 179)
Pressure gauge (Option) 43
40
IN side gauge port OUT side gauge port
Rc 1/8 Rc 1/8

IN port
Rc 1/2
62
172

8
OUT port Silencer (Option)
Rc 1/2
22
62.8

32
96 130 EXH port
3.2

4 x ø12
116 150 Rc 1/2

VBA43A-04 404
(When silencer installed: 224)
(When high-noise reduction
40 silencer installed: 230)
Pressure gauge (Option)
43
IN side gauge port OUT side gauge port
Rc 1/8 Rc 1/8

IN port
221

Rc 1/2
62

8
OUT port Silencer (Option)
Rc 1/2
22
62.8

32

96 130 EXH port


4 x ø12
3.2

116 150 Rc 1/2


(When silencer installed: 224)
(When high-noise reduction
silencer installed: 230)

For detailed dimensions, specifications


and lead times, please contact SMC.
Made to Order

1 Copper-free/Fluorine-free 2 CE explosion-proof directive (ATEX) compliant 3 Ozone resistant


The inner or outer copper parts material has Ozone resistance is strengthened through
been changed to stainless steel or 56 Standard model no. the use of fluororubber (diaphragm) and
aluminum. The fluorine resin parts has been hydrogenated NBR (valve, rod seal) for the
changed to general resin. Made to Order rubber parts of the seal material.
CE explosion-proof directive (ATEX):
20 Standard model no. Category 3GD 80 Standard model no.
Made to Order Made to Order
Copper-free/Fluorine-free Ozone resistant
∗ For booster regulator with pressure gauge, please consult SMC. ∗ Weather resistant NBR (diaphragm) and
∗ This option cannot be selected for air tank with safety valve. hydrogenated NBR (valve) are used for the rubber
parts of the standard model.
11
Air Tank

Series VBAT RoHS

Made to Order
How to Order (For details, refer to page 11.)

• Compact connections are Standard Product


possible with booster (For Japanese Market) Note) The thread type for each port is Rc.

regulators.
• It can be used alone as a tank. VBAT 10 A 1 S
• Also partially compatible with Tank internal Option
overseas standards capacity Symbol Option
Nil None
Symbol Internal capacity
05 5L
V Drain valve
10 10 L Option
20 20 L Symbol Option Applicable model
38 38 L Nil None Note) All models
Safety valve VBAT05A1, VBAT10A1
Material R (Set pressure: 1 MPa) VBAT20A1, VBAT38A1
VBAT05A1 Symbol Material
Safety valve VBAT05A1
A Carbon steel (SS400) S (Set pressure: 2 MPa) VBAT10A1
S Stainless steel 304
Note) A safety valve port is provided only when option R or S is selected.

VBAT10S1
CE Certified Product

VBAT 10 A F SV Q
Tank internal CE certified product
VBAT20S1 (Self-declaration document attached)
capacity
Symbol Internal capacity
05 5L Accessories
10 10 L Symbol Accessories Applicable model
20 20 L Safety valve (Set pressure: 1 MPa) VBAT20A
RV Drain valve VBAT38A
38 38 L
Safety valve (Set pressure: 2 MPa) VBAT05A
Material SV Drain valve VBAT10A
VBAT38A1
Symbol Material
A Carbon steel (SS400) Thread type
Symbol Thread type
Caution Nil
F
Rc
G
When used as a single unit (not
connected with a booster regulator) and Product Not Applicable
pressurized at over 1 MPa at normal to the ASME Standard
temperatures, the air tank falls under the
scope of the “High Pressure Gas Safety
Act” in Japan. VBAT 05 A N 1 SV X11
Tank internal Product not applicable
capacity to the ASME standard
Option
Symbol Internal capacity
Symbol Option
05 5L
Nil None Note 1)
10 10 L
V Drain valve Note 1)
Material S Safety valve (Set pressure: 2 MPa) Note 1)
Symbol Material Safety valve (Set pressure: 2 MPa) Note 2)
SV Drain valve
A Carbon steel (SS400)
Thread type Note 1) Customers are responsible for preparing a safety
valve.
Symbol Thread type Note 2) Safety valve does not meet ASME specifications.
Nil Rc
N NPT Note)
Note) Pressure unit of NPT products: psi. This
product is for overseas use only according
to the new Measurement Law. (The SI unit
type is provided for use in Japan.)
12
Series VBAT

Specifications Design

Standard Product (For Japanese Market) Warning


1. Operating pressure
Model VBAT05l1 VBAT10l1 VBAT20l1 VBAT38l1 • Operate this product below the maximum operat-
Fluid Compressed air ing pressure. If it is necessary, take appropriate
Tank capacity (L) 5 10 20 38 safety measures to ensure that the maximum op-
erating pressure is not exceeded.
Max. operating VBATlA1 2.0 1.0 • When the tank alone is used
pressure (MPa) VBATlS1 2.0 Use a pressure switch or a safety valve to ensure
that the maximum operating pressure is not ex-
IN port size 3/8 3/8 1/2 1/2 ceeded.
OUT port size 3/8 1/2 1/2 3/4 2. Connection
Ambient and fluid temperature (°C) 0 to 75 • Connect a filter or a mist separator to the OUT
side of the tank. Because the inner surface of the
VBATlA1 6.6 10 14 21 tank is untreated, there is a possibility of dust
Weight (kg)
VBATlS1 3.2 4.9 12 19 flowing out to the outlet side.
VBATlA1 Carbon steel (SS400) • A VBA booster regulator can be connected
Material directly with the tank accessories as indicated
VBATlS1 Stainless steel 304 combinations below.
VBATlA1 Outside: Silver paint, Inside: Rustproof paint Booster regulator
Paint
VBATlS1 None
VBA1lA VBA2lA VBA4lA
Note) The accessories and options are included in the same container. VBAT05A
VBAT05S P — —
VBAT10A
P P

Air tank
VBAT10S

CE Certified Product VBAT20A
VBAT20S
— P P
Model
VBAT05A VBAT10A VBAT20A VBAT38A VBAT38A — P P
l-SV-Q l-SV-Q l-RV-Q l-SV-Q VBAT38S
Fluid Compressed air
Tank capacity (L) 5 10 20 38 Selection
Max. operating pressure (MPa) 2.0 1.0
IN port size 3/8 1/2 3/4 3/4 Caution
OUT port size 3/8 1/2 1/2 3/4 • Consider the operating conditions and operate
this product within the specification range.
Ambient and fluid temperature (°C) 0 to 75 • When using the air tank with a booster regulator,
Weight (kg) 6.6 10 14 21 refer to “Sizing” on page 5 or SMC Pneumatic
Carbon steel (SS400) System Energy Saving Program.
Material
Paint Outside: Silver paint, Inside: Rustproof paint
Mounting
Note) The accessories and options are included in the same container.
Caution
1. Accessories
Product Not Applicable to the ASME Standard • Refer to the operation manual (VBAT-M1, M2,
M3, M4) regarding combining booster regulators
Model VBAT05Al1-l-X11 VBAT10Al1-l-X11 with older model air tanks.
Fluid Compressed air • The accessories are secured by bands to the feet
of the air tank. Once removed, make sure not to
Tank capacity (L) 5 10 lose them.
Max. operating pressure (MPa) 2.0 2. Installation
IN port size 3/8 3/8 • Install the tank away from people. It is dangerous
if the accumulated air inside the tank were to
OUT port size 3/8 1/2 seep out.
Ambient and fluid temperature (°C) 0 to 75 • Do not mount the air tank on a moving part or a
Weight (kg) 6.6 11 place with vibration.
• When connecting a booster regulator with the
Material Carbon steel (SS400) tank, refer to the operation manual first, which is
Paint Outside: Silver paint, Inside: Rustproof paint provided with the air tank before assembling.
• Refer to the operation manual regarding mount-
Note) The accessories and options are included in the same container. ing methods when using long bolts.
• To mount the air tank on a floor surface, use the
four holes to secure the tank with bolts or anchor
bolts.

Maintenance
Warning
1. Inspection
• The use of pressure vessels could lead to an un-
expected accident due to external damage or
internal corrosion caused by drainage. Therefore,
make sure to check periodically for external
damage, or the extent of internal corrosion
through the port hole. An ultrasonic thickness
indicator may also be used to check for any re-
duction in material thickness.
2. Draining
• If this product is used with a large amount of
drainage, the drainage could flow out, leading to
equipment malfunction or corrosion inside the
tank. Therefore, drain the system once a day.
13
Air Tank Series VBAT

List of Air Tank for Overseas


Exportable models
Country/Region Law Details
Material: Carbon steel Material: Stainless steel
VBAT05A-SV-X102 Product complies with ASME
Singapore, VBAT10A-SV-X102 specifications
Factory Act
Malaysia VBAT20A-RV-X102 JBA (Japan Boiler Association)
VBAT38A-RV-X102 certification attached
Thailand, Taiwan No applicable standard Standard product

Options/Accessories/Part No.
<Standard Product>
For VBATlA1 (Carbon Steel)
Model VBAT05A1-l VBAT10A1-l VBAT20A1-l VBAT38A1-l
Accessory kit VBAT5A-Y-3 VBAT10A-Y-3 VBAT20A-Y-3
Safety valve (When selecting an option) Note 1) 2) VBAT-R (Set pressure: 1 MPa), VBAT-S (Set pressure: 2 MPa) VBAT-R (Set pressure: 1 MPa)
Drain valve (When selecting an option) VBAT-V1
Note 1) The set pressure of the safety valve cannot be changed.
Note 2) The safety valve is a safety measure that protects the tank from excess pressure. The valve opens automatically when the specified pressure is reached, releasing excess
pressure inside the tank. The valve closes again when the pressure drops below a designated value. Select a pressure valve appropriate for the maximum operating
pressure specification of the tank.

For VBATlS1 (Stainless Steel)


Model VBAT05S1-l VBAT10S1-l VBAT20S1-l VBAT38S1-l
Accessory kit VBAT5S-Y-4 VBAT10S-Y-4 VBAT20A-Y-4
Drain valve (When selecting an option) VBAT-V1

<CE Certified Product>


Model VBAT05Al-SV-Q VBAT10Al-SV-Q VBAT20Al-RV-Q VBAT38Al-RV-Q
Accessory kit VBAT5A-Y-2 VBAT10A-Y-2 VBAT20A-Y-2
Safety valve VBAT-S (Set pressure: 2 MPa) VBAT-R (Set pressure: 1 MPa)
Drain valve VBAT-V1

<Product Not Applicable to the ASME Standard>


Model VBAT05A∗1-l-X11 VBAT10A∗1-l-X11
Accessory kit VBAT5A-Y-3∗ VBAT10A-Y-3∗
Safety valve (When selecting an option) VBAT-S∗ (Set pressure: 2 MPa)
Drain valve VBAT-V1∗
Note) ∗: Nil when Rc thread is selected, N when NPT thread is selected.

Drain valve VBAT-V1∗ Safety valve VBAT-R, VBAT-S∗


Safety
valve IN PORT
1/4

ø18.5
52
20
58 (CLOSE) to

65
63 (OPEN)

OUT PORT
1/8
19
3/8
Drain valve 19
ø30

For detailed dimensions, specifications


Made to Order and lead times, please contact SMC.

1 Copper-free/Fluorine-free
20 VBAT 10 A 1 V
Made to Order
Copper-free/ With drain valve
Tank internal
Fluorine-free capacity Material Note 1) The thread type for each port is Rc.
Note 2) A stainless steel fitting and a drain valve are included in the
Symbol Internal capacity Symbol Material
same container as accessories. (For detailed dimensions,
05 5L A Carbon steel (SS400)
please contact SMC.) A safety valve cannot be selected.
10 10 L S Stainless steel 304 Note 3) Since neither copper nor fluorine parts are used for the
20 20 L tank, a standard model can be used when options (safety
38 38 L valve and drain valve) are not necessary.

14
Series VBAT

Dimensions: Standard Product (For Japanese Market)


Tank IN port Booster regulator
VBAT05A1 Material: Carbon steel Rc 3/8 Spare port IN port
Rc 1/2 Rc 1/4
Connected to VBA10A, 11A
EXH: Rc 1/4
60

(370)
OUT

(307)
Tank OUT port

257
Rc 3/8 56
ø1

163
4 x ø11
32 32

200 100
338 160
Drain port
349∗ Rc 1/4 ∗ The length may be longer than the specification
if the plugs mounted on the tank are not fit to the end.

Tank IN port
VBAT10A1 Material: Carbon steel Rc 3/8 Booster regulator
IN port
Spare port
Connected to VBA10A, 11A Rc 1/4
Rc 1/2
EXH: Rc 1/4

(391)
60

(328)
OUT

278
Tank OUT port
Rc 1/2 80
ø1
170
4 x ø11
32 32

312 120
460 Drain port 180
471∗ Rc 1/4
∗ The length may be longer than the specification
if the plugs mounted on the tank are not fit to the end.

Connected to VBA20A Connected to VBA22A


Tank IN port
Rc 3/8 Booster regulator
IN port Booster regulator IN port
Spare port Rc 3/8 Rc 3/8
Rc 1/2
EXH: Rc 3/8 EXH: Rc 3/8
(454)

442
(417)

60
(367)
(367)

OUT OUT
Tank OUT port
278

0
Rc 1/2 ø18 80
ø1
170

32 32 4 x ø11 4 x ø11

312 120 120


460 Drain port 180 180
471∗ Rc 1/4
∗ The length may be longer than the specification
if the plugs mounted on the tank are not fit to the end.

VBAT20A1 Material: Carbon steel


Connected to VBA20A, 40A Tank IN port Connected to VBA22A, 42A
Rc 1/2 Booster regulator
IN port Booster regulator IN port
Tank OUT port C
Spare port
C
Rc 1/2
Rc 1/2 EXH: C EXH: C
(A)

(A)

D
(B)

(B)

OUT OUT
305

6
ø20 4 x ø13 ø20
6
180

4 x ø13
50 50

400 100 100


674 Drain port 200 200
Rc 1/4 (mm)
685∗
Booster regulator model A B C D Note)
VBA20A 481 394 Rc 3/8 —
∗ The length may be longer than the specification if the plugs mounted on the tank are not fit to the end. —
VBA40A 520 429.8 Rc 1/2
VBA22A 444 394 Rc 3/8 469
VBA42A 477 429.8 Rc 1/2 493
Note) When option G (pressure gauge) is selected
15
Air Tank Series VBAT

Dimensions: Standard Product (For Japanese Market)

VBAT38A1 Material: Carbon steel


Tank IN port
Connected to VBA20A, 40A Connected to VBA22A, 42A
Rc 1/2
Booster regulator IN port Booster regulator IN port
C C
Spare port
Rc 1/2 EXH: C EXH: C

(A)

(A)
Tank OUT port

D
(B)

(B)
Rc 3/4 OUT OUT
355

ø 256 56
4 x ø13 ø2
205

4 x ø13
50 50

500 150 150


824 Drain port 250 250
835∗ Rc 1/4 (mm)
Booster regulator model A B C D Note)
VBA20A 531 444 Rc 3/8 —
∗ The length may be longer than the specification if the plugs mounted on the tank are not fit to the end. VBA40A 570 479.8 Rc 1/2 —
VBA22A 494 444 Rc 3/8 519
VBA42A 527 479.8 Rc 1/2 543
Note) When option G (pressure gauge) is selected

Tank IN port
VBAT05S1 Material: Stainless steel 304 Rc 3/8
Booster regulator
IN port
Rc 1/4
Connected to VBA10A, 11A
EXH: Rc 1/4
60
(370)

OUT
(307)

Tank OUT port


257

Rc 3/8 60
ø1
163

32 32 4 x ø11

Drain port
100
Rc 1/4
200 160
300

VBAT10S1 Material: Stainless steel 304 Tank IN port Booster regulator


Rc 3/8 IN port
Rc 1/4
Connected to VBA10A, 11A
EXH: Rc 1/4
(391)

60
OUT
(328)

Tank OUT port


278

Rc 1/2
80
170

ø1
32 32 4 x ø11

Drain port 120


Rc 1/4 180
312
460

Connected to VBA20A Connected to VBA22A


Tank IN port
Rc 3/8 Booster regulator
IN port Booster regulator IN port
Rc 3/8 Rc 3/8

EXH: Rc 3/8 EXH: Rc 3/8


(454)

442
(417)

Tank OUT port


(367)
(367)

Rc 1/2 OUT OUT


278

ø180 80
ø1
170

32 32 4 x ø11 4 x ø11

Drain port 120 120


312 Rc 1/4 180 180

16
Series VBAT

Dimensions: Standard Product (For Japanese Market)

VBAT20S1 Material: Stainless steel 304


Connected to VBA20A, 40A Connected to VBA22A, 42A, 43A
Tank IN port
Rc 1/2 Booster regulator
IN port Booster regulator IN port
Tank OUT port C C
Rc 1/2
EXH: C EXH: C

(A)

(A)

D
(B)
(B)
OUT OUT
305

6
ø20 06
ø2 4 x ø13
180

4 x ø13
50 50

Drain port 100 100


Rc 1/4 200 200
400 (mm)
674 Booster regulator model A B C D Note)
VBA20A 481 394 Rc 3/8 —
VBA40A 520 429.8 Rc 1/2 —
VBA22A 444 394 Rc 3/8 469
VBA42A 477 429.8 Rc 1/2 493
VBA43A 526 — — —
Note) When option G (pressure gauge) is selected

VBAT38S1 Material: Stainless steel 304


Connected to VBA20A, 40A Connected to VBA22A, 42A, 43A
Tank IN port
Rc 1/2 Booster regulator
IN port Booster regulator IN port
C C

EXH: C EXH: C
(A)

Tank OUT port


(A)

D
(B)

(B)

Rc 3/4 OUT OUT


355

ø256 56
ø2
205

4 x ø13 4 x ø13
50 50

150 150
500
250 250
824
(mm)
Drain port Booster regulator model A B C D Note)
Rc 1/4 VBA20A 531 444 Rc 3/8 —
VBA40A 570 479.8 Rc 1/2 —
VBA22A 494 444 Rc 3/8 519
VBA42A 527 479.8 Rc 1/2 543
VBA43A 576 — — —
Note) When option G (pressure gauge) is selected

VBAT 05 R
10 A1- S VBAT 20 R
38 A1- S
With safety valve With safety valve

Safety valve port


Rc 3/8
Safety valve port
Rc 3/8
250
A
(mm)
Tank model A
VBAT05 60
VBAT10 130

17
Air Tank Series VBAT

Dimensions: CE Certified Product

VBAT05A-Q Material: Carbon steel


Connected to VBA10A, 11A
Safety valve port Tank IN port
Rc 3/8 Rc 3/8
Booster regulator
Spare port IN port
2 x Rc 1/2 Rc 1/4
EXH: Rc 1/4
60 60

(370)
OUT

(307)
257
Tank OUT port
56
Rc 3/8 ø1

163
4 x ø11
32 32

Drain port 100


Rc 1/4 200 160
338
360∗

∗ The length may be longer than the specification if the plugs mounted on the tank are not fit to the end.
The length of G thread type is about 6 mm longer due to plug type differences.

VBAT10A-Q Material: Carbon steel


Connected to VBA10A, 11A
Safety valve port
Rc 3/8 Tank IN port
Booster regulator
Rc 1/2 IN port
Spare port
2 x Rc 1/2 Rc 1/4
EXH: Rc 1/4

130 60
(391)

OUT
(328)
278

Tank OUT port


Rc 1/2 80
ø1
170

32 32 4 x ø11

Drain port 120


Rc 1/4 312 180
460
482∗

∗ The length may be longer than the specification if the plugs mounted on the tank are not fit to the end.
The length of G thread type is about 6 mm longer due to plug type differences.

Connected to VBA20A Connected to VBA22A


Tank IN port
Safety valve port Rc 1/2 Booster regulator
Rc 3/8 IN port Booster regulator IN port
Spare port Rc 3/8 Rc 3/8
2 x Rc 1/2
EXH: Rc 3/8 EXH: Rc 3/8
(454)

442∗

130 60
(417)

OUT OUT
(367)

(367)

Tank OUT port


278

Rc 1/2 80 80
ø1 ø1
170

4 x ø11 4 x ø11
32 32

312 120 120


Drain port 180 180
460 Rc 1/4
482∗ ∗ When option G (pressure gauge) is selected

∗ The length may be longer than the specification if the plugs mounted on the tank are not fit to the end.
The length of G thread type is about 6 mm longer due to plug type differences.
18
Series VBAT

Dimensions: CE Certified Product

VBAT20A-Q Material: Carbon steel


Connected to VBA20A, 40A Connected to VBA22A, 42A
Tank IN port
Rc 3/4
Safety valve port Booster regulator
Rc 3/8 IN port Booster regulator IN port
C C

EXH: C EXH: C

(A)
Spare port

D
(A)
250
2 x Rc 1/2 OUT OUT

(B)

(B)
305

Tank OUT port


Rc 1/2 06 06
ø2 ø2
180

4 x ø13 4 x ø13
50 Drain port 50
Rc 1/4
400 100 100
674 200
200
696∗
(mm)
∗ The length may be longer than the specification if the plugs mounted on the tank are not fit to the end.
Booster regulator model A B C D Note)
The length of G thread type is about 6 mm longer due to plug type differences. VBA20A 481 394 Rc 3/8 —
VBA40A 520 429.8 Rc 1/2 —
VBA22A 444 394 Rc 3/8 469
VBA42A 477 429.8 Rc 1/2 493
Note) When option G (pressure gauge) is selected

VBAT38A-Q Material: Carbon steel


Connected to VBA20A, 40A Connected to VBA22A, 42A
Tank IN port
Rc 3/4
Booster regulator
Safety valve port IN port Booster regulator IN port
Rc 3/8 C C
Spare port
2 x Rc 1/2
EXH: C EXH: C
(A)

250
(A)

D
(B)

(B)

OUT OUT
355

Tank OUT port


Rc 3/4 56
56 ø2
ø2
205

4 x ø13 4 x ø13
50 50
Drain port
Rc 1/4
500 150 150

824 250 250


846∗ (mm)
Booster regulator model A B C D Note)
∗ The length may be longer than the specification if the plugs mounted on the tank are not fit to the end. —
VBA20A 531 444 Rc 3/8
The length of G thread type is about 6 mm longer due to plug type differences. —
VBA40A 570 479.8 Rc 1/2
VBA22A 494 444 Rc 3/8 519
VBA42A 527 479.8 Rc 1/2 543
Note) When option G (pressure gauge) is selected

19
Air Tank Series VBAT

Dimensions: Product Not Applicable to the ASME Standard

VBAT05A1-X11 Material: Carbon steel


Connected to VBA10A, 11A
Safety valve port Tank IN port
Rc 3/8 Rc 3/8
Booster regulator
Spare port IN port
Rc 1/2 Rc 1/4
EXH: Rc 1/4

(370)
60 60
OUT

(307)
257
Tank OUT port
56
Rc 3/8 ø1
163

4 x ø11
32 32

Drain port
Rc 1/4 100

200 160

338
349∗
∗ The length may be longer than the specification if the plugs mounted on the tank are not fit to the end.

VBAT10A1-X11 Material: Carbon steel


Connected to VBA10A, 11A
Safety valve port
Rc 3/8
Tank IN port
Rc 3/8 Booster regulator
Spare port IN port
Rc 1/2 Rc 1/4
EXH: Rc 1/4
190
(364)

OUT
(301)

Tank OUT port


251

Rc 1/2 56
ø1
163

4 x ø11
32 32

Drain port 120


Rc 1/4
312 180
625
636∗
∗ The length may be longer than the specification if the plugs mounted on the tank are not fit to the end.

Connected to VBA20A Connected to VBA22A

Tank IN port
Rc 3/8 Booster regulator
Safety valve IN port Booster regulator IN port
port Spare port Rc 3/8 Rc 3/8
Rc 3/8 Rc 1/2
EXH: Rc 3/8
(427)

EXH: Rc 3/8
(390)

190
(340)

(340)

OUT OUT
Tank OUT port
251

Rc 1/2 56 56
ø1 ø1
163

32 32 4 x ø11 4 x ø11

Drain port 120 120


Rc 1/4
180 180
312
625
636∗
∗ The length may be longer than the specification if the plugs mounted on the tank are not fit to the end.

20
These safety instructions are intended to prevent hazardous situations and/or
Safety Instructions equipment damage. These instructions indicate the level of potential hazard with
the labels of “Caution,” “Warning” or “Danger.” They are all important notes for
safety and must be followed in addition to International Standards (ISO/IEC)∗1),
and other safety regulations.
∗1) ISO 4414: Pneumatic fluid power – General rules relating to systems.
Caution indicates a hazard with a low level of risk ISO 4413: Hydraulic fluid power – General rules relating to systems.
Caution: which, if not avoided, could result in minor or IEC 60204-1: Safety of machinery – Electrical equipment of machines.
moderate injury.
(Part 1: General requirements)
Warning indicates a hazard with a medium level of ISO 10218-1: Manipulating industrial robots - Safety.
Warning: risk which, if not avoided, could result in death or etc.
serious injury.
Danger indicates a hazard with a high level of risk
Danger : which, if not avoided, will result in death or serious
injury.

Warning Caution
1. The compatibility of the product is the responsibility of the 1. The product is provided for use in manufacturing industries.
person who designs the equipment or decides its specifications. The product herein described is basically provided for peaceful use in
Since the product specified here is used under various operating conditions, its manufacturing industries.
compatibility with specific equipment must be decided by the person who designs If considering using the product in other industries, consult SMC beforehand and
the equipment or decides its specifications based on necessary analysis and test
exchange specifications or a contract if necessary.
results. The expected performance and safety assurance of the equipment will be
If anything is unclear, contact your nearest sales branch.
the responsibility of the person who has determined its compatibility with the
product. This person should also continuously review all specifications of the
product referring to its latest catalog information, with a view to giving due
consideration to any possibility of equipment failure when configuring the Limited warranty and Disclaimer/
equipment.
2. Only personnel with appropriate training should operate
Compliance Requirements
machinery and equipment. The product used is subject to the following “Limited warranty and Disclaimer”
The product specified here may become unsafe if handled incorrectly. The and “Compliance Requirements”.
assembly, operation and maintenance of machines or equipment including our Read and accept them before using the product.
products must be performed by an operator who is appropriately trained and
experienced. Limited warranty and Disclaimer
3. Do not service or attempt to remove product and
machinery/equipment until safety is confirmed. 1. The warranty period of the product is 1 year in service or 1.5 years after
1. The inspection and maintenance of machinery/equipment should only be the product is delivered.∗2)
performed after measures to prevent falling or runaway of the driven objects Also, the product may have specified durability, running distance or
have been confirmed. replacement parts. Please consult your nearest sales branch.
2. When the product is to be removed, confirm that the safety measures as
mentioned above are implemented and the power from any appropriate source 2. For any failure or damage reported within the warranty period which is clearly our
is cut, and read and understand the specific product precautions of all relevant responsibility, a replacement product or necessary parts will be provided.
products carefully. This limited warranty applies only to our product independently, and not to any
3. Before machinery/equipment is restarted, take measures to prevent other damage incurred due to the failure of the product.
unexpected operation and malfunction.
4. Contact SMC beforehand and take special consideration of safety 3. Prior to using SMC products, please read and understand the warranty terms
measures if the product is to be used in any of the following and disclaimers noted in the specified catalog for the particular products.
conditions. ∗2) Vacuum pads are excluded from this 1 year warranty.
A vacuum pad is a consumable part, so it is warranted for a year after it is delivered.
1. Conditions and environments outside of the given specifications, or use
Also, even within the warranty period, the wear of a product due to the use of the vacuum pad
outdoors or in a place exposed to direct sunlight.
or failure due to the deterioration of rubber material are not covered by the limited warranty.
2. Installation on equipment in conjunction with atomic energy, railways, air
navigation, space, shipping, vehicles, military, medical treatment, combustion
and recreation, or equipment in contact with food and beverages, emergency Compliance Requirements
stop circuits, clutch and brake circuits in press applications, safety equipment
or other applications unsuitable for the standard specifications described in the 1. The use of SMC products with production equipment for the manufacture of
product catalog. weapons of mass destruction (WMD) or any other weapon is strictly prohibited.
3. An application which could have negative effects on people, property, or
animals requiring special safety analysis. 2. The exports of SMC products or technology from one country to another are
4. Use in an interlock circuit, which requires the provision of double interlock for governed by the relevant security laws and regulations of the countries involved
possible failure by using a mechanical protective function, and periodical in the transaction. Prior to the shipment of a SMC product to another country,
checks to confirm proper operation. assure that all local rules governing that export are known and followed.

Edition B ∗ Addition of booster regulators/air-operated type, VBA22A/42A Edition D ∗ Addition of booster regulator, VBA11A
∗ Addition of booster regulator with max. operating pressure of ∗ Deletion of booster regulator, VBA1111
Revision history

1.6 MPa, VBA43A ∗ Addition of air tanks, CE certified


∗ Number of pages increased from 24 to 28 MY ∗ Addition of air tanks, not applicable to the ASME standard
∗ Addition of an elbow silencer to options
Edition C ∗ Addition of booster regulator, VBA10A
∗ Number of pages increased from 20 to 24 OW
∗ Deletion of booster regulator, VBA1110
Change of accessories/part no. of air tank, VBAT series
Change of dimensions of air tank, VBAT series
∗ Number of pages decreased from 28 to 20 NY

Safety Instructions Be sure to read “Handling Precautions for SMC Products” (M-E03-3) before using.

Akihabara UDX 15F,


4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021, JAPAN
Phone: 03-5207-8249 Fax: 03-5298-5362
URL http://www.smcworld.com
© 2010 SMC Corporation All Rights Reserved