You are on page 1of 5

INTERNATIONAL INSPECTION SERVICES PVT. LTD.

(IIS Testing BD Pvt. Ltd.)


--------------------------------------------------------------------------
ANNEX NO. - IISPL/2020/1608/184/250T/001
Oriental Construction Co.
Customer Rasul View (3rd Floor) 65, Maymensing Lane, Banglamotor, Dhaka-1000

Client Ref. No. IISPL/QUOT/ID/2020/1608/184

Location of Inspection Bashundhara Food & Beverage, Keranigonj, Dhaka, Bangladesh

Date of Inspection 16-08-2020

Detail of Equipment
Name of the equipment 250 Ton Crawler Crane

Make/Manufacturer SUMITOMO, JAPAN

Type/Model SC2500

Serial No. SC250-0004

Mfg. date 2001

Max. Rated Lifting Capacity 250 ton

Visual /Observation
S Un R AR Remarks
Marking 
Load Hook & Blocks 
Wire Rope and End Connection 
Handrails, Walkways, and Ladders 
Tires condition/Crawler Condition 
Lights in front and backside 
Functioning of Horn 
Lowering and Lifting of Boom Structure 
All gauges 
Brake and Brake Lights 
Indicators Front / Back (Right , Left) 
Lubrication of Wire Rope, chain and sprocket 
Driver protector 
Load chart is displayed. 
Fire extinguisher 
Reverse warning light/alarm/cabin light 
Diesel tank cap is installed 
Condition of Crane boom 
Page 1 of 5
Bangladesh Office: House: 426 (5th Floor), Flat # K, Road: 30, Mohakhali DOHS, Dhaka-1206,Bangladesh. Tel:+88-02-48811446
Regional Head Office: Plot No. 29, # 5-6-137/6/4/2, Near Sai Baba Temple, Kukatpally, Hyderabad - 500072, India.
International Head Office: BLK 473, Choa Chukang, Avenue 3, # 13-165, Singapore – 680473
www.iispl.net
INTERNATIONAL INSPECTION SERVICES PVT. LTD.
(IIS Testing BD Pvt. Ltd.)
--------------------------------------------------------------------------
ANNEX NO. - IISPL/2020/1608/184/250T/001
Out rigger/Crawler Condition 
Safe Load Indication (SLI) 
Battery Condition 
Fastening or Securing Loads for Mechanical
Lifting such as
A: Condition of Main wire rope 
B: Pulleys / Sheaves 
C: Hook , Swivel & Link 
D: Clamps 
Cracked, deformation on corroded member 
Boom lights/other lights 
Check if the limiting switches are automatic
x
& satisfactory for
A: Hoist ( Close Condition) 
B: Max. Hoist Limit switch (Main) 
C: Max. Angle Limit 
Air and hydraulic system ( Hoses, Tubes &

Fittings)
Crane book/documentation review. 
Swing operation at 90oR/L 
Swinging Indication/ Swinging Lock 

Function Test
S Un R AR Remarks
Starting Engine 
Engine Vibration 
Engine Noise 
Engine Operation 

o S: Satisfactory
o Un: Unsatisfactory
o R: Repairable
o AR: After Repair

Load Test
Description of Test Boom Radius Test SWL
Length Load
Meter Meter Ton Ton

110% SWL Test 60.95 32.0 19.5 17.8

Load test duration: 30 minutes

Results: Accepted

Page 2 of 5
Bangladesh Office: House: 426 (5th Floor), Flat # K, Road: 30, Mohakhali DOHS, Dhaka-1206,Bangladesh. Tel:+88-02-48811446
Regional Head Office: Plot No. 29, # 5-6-137/6/4/2, Near Sai Baba Temple, Kukatpally, Hyderabad - 500072, India.
International Head Office: BLK 473, Choa Chukang, Avenue 3, # 13-165, Singapore – 680473
www.iispl.net
INTERNATIONAL INSPECTION SERVICES PVT. LTD.
(IIS Testing BD Pvt. Ltd.)
--------------------------------------------------------------------------
ANNEX NO. - IISPL/2020/1608/184/250T/001

Conclusion & Recommendation: Recommended for further use.

“This Certificate does not make any warranty/indemnity expressed or implied, relating to the above equipment. This Certificate does not
relieve seller/suppliers from their contractual responsibilities with regard to quality/quantity of this delivery nor does it discrimination
the buyer’s right of claim towards their seller/suppliers for compensation for any apparent and/or hidden defects not detected during
our inspection & testing or occurring thereafter.”

ANNEXES Yes (Total number of pages: 0) No

Issued by: Checked by:


Name: Ashis Kumar Suttradhar Name: Ripan K Prodhan

Signature: Signature:
Date of issue: August 17, 2020
Date of Validity: August 15, 2021
Inspection center: IISPL Bangladesh

Page 3 of 5
Bangladesh Office: House: 426 (5th Floor), Flat # K, Road: 30, Mohakhali DOHS, Dhaka-1206,Bangladesh. Tel:+88-02-48811446
Regional Head Office: Plot No. 29, # 5-6-137/6/4/2, Near Sai Baba Temple, Kukatpally, Hyderabad - 500072, India.
International Head Office: BLK 473, Choa Chukang, Avenue 3, # 13-165, Singapore – 680473
www.iispl.net
INTERNATIONAL INSPECTION SERVICES PVT. LTD.
(IIS Testing BD Pvt. Ltd.)
--------------------------------------------------------------------------
ANNEX NO. - IISPL/2020/1608/184/250T/001
Photographs of the equipment during inspection

General view

Name Plate Load Chart


Page 4 of 5
Bangladesh Office: House: 426 (5th Floor), Flat # K, Road: 30, Mohakhali DOHS, Dhaka-1206,Bangladesh. Tel:+88-02-48811446
Regional Head Office: Plot No. 29, # 5-6-137/6/4/2, Near Sai Baba Temple, Kukatpally, Hyderabad - 500072, India.
International Head Office: BLK 473, Choa Chukang, Avenue 3, # 13-165, Singapore – 680473
www.iispl.net
INTERNATIONAL INSPECTION SERVICES PVT. LTD.
(IIS Testing BD Pvt. Ltd.)
--------------------------------------------------------------------------
ANNEX NO. - IISPL/2020/1608/184/250T/001

SLI Overall Wire Rope Condition

Crawler Condition Battery Condition

Others
…END OF REPORT…