You are on page 1of 81
OWds40P° “HULL GMGO739" OMG INTERNATIONAL SHIPBUILDING & TRADING CO.,LTD. PNEUMATIC BULK CEMENT AND MUD HANDLING SYSTEM 1, GENERAL ‘There are four (4) bulk storage tanks installed in a forwaré compartment, each of 4,400mm diameter by 4,000mm overall height and having a net capacity of 1500 CUF. Segregated pipe lines are used such that one line is for cement (two tanks) and the other for bulk mud (two tanks), besides any material can be stored in any tank without contamination, ‘Tho system is fitted with remote control and monitoring eqaipment and is controlled from a remote control panel fitted in the wheelho.se, Compressed sir for the system is from two (2) air compressor units complete with sea water cooled air after-coolers each delivers 18.0m*/min. at 5.6kg/cm®* (80 PSI), in addition, two (2) refrigeration air dryers are provided in air supply lines. Bach tank has its own piping system for filling and discharge and its pipe lines are connected with each other in the bulk tank room on the way to deck manifolds located in the mid part of the vessel Bach cargo system, barite, bentonite and cement, has its own piping system to prevent contamination, ‘The system is arranged so that bull material discharge cant be mace from either the port or starboard side at the midships discharge manifolds. ‘The discharge lines and manifolds are also used as filling lines for loading bulk material from ashore or from other vessels. Aft discharge manifolds are also arranged at the port side at the stern part of vessel (One compressor only is normally used to unload material from each tank. When fast discharge is required, particularly for heavier materials, both ‘compressors may be used to discharge a single tank. In the case of one compressor malfunctioning, the other compressor can be used to discharge any tank. Whenever one compressor is used for the discharge of all tanks, the air by-pass valve (cross-over valve) must be always opened Besides, any two storage tanks in different material systems can also be discharged or filled at the same time, UUSLIP° ‘To unload two different materials simultaneously, it is necessary to use ‘two compressors that feed into each common air inlet Ii ‘That is the No.1 compressor is used for either the No.1 or No.2 tanks and the No.2 compressor is for either the No.3 or No.4 tanks (the air by-pass valve must be closed), and for this reason there may be considerable unbalance in the discharge rate due to different specific gravity of each ‘material from the two storage tanks, as the system is basicelly designed for the discharge of only one cargo at a time. Do not attempt to discharge two tanks simultaneously by using only one compressor, as each compressor unit is matched especially for the discharge of single tank. All discharge, external bulk loading, venting and tank cleaning operations fare controlled from the remote control console in the wheelhouse, Indicator lamps on the control panel show if the valve is open or closed, a red lamp for closed position and a green lamp for open positon. In the case of the jet purge air valves, these are capable of variable opening, control and are provided with variable controls and analogue type opening indicators on the control panel. ‘The pressure in the tanks is indicated by pressure gauges on the panel, ‘which allows the operator to monitor the working pressure and control jet purge air supply to the discharge line during discharge of the tanks, Compressors are controlled from the panel by means of stop and start buttons, If compressor should stop automatically because of some alarm condition such as “HIGH AIR TEMPERATURE”, an alarm buzzer will sound at the control panel and the condition causing the automatic stop will be indicated fon the starter panel on the compressor unit. When filling the storage tanks, and when tanks are almos: full indicators showing red lamp "HI-LEVEL" will be lit and buzzer sounded on the panel. This does not show the tank is completely full but the position in which filling line should be purged, as only sufficient capacity remains in the tank to take line's contents, Each tank has a self-cleaning device inside it, so that residue material left in the tank after discharge is reduced to an absolute minimum. ‘This cleaning device is to be used during discharge or after discharge by remote operation ‘Therefore, cleaning procedure is recommended if it is necessary to thoroughly strip the tank of bulk material for survey, or for use for another material on next voyage. OWdshde® ‘The emergency shut-down system is included in the remote control panel and on the main deck. Pressing the emergency stop will stop compressors instantly and all valves will be staying at closed position immediately, except manual valves, and should only be used in emergency situations. ‘The display will indicate “RED LAMP" on the emergency press button and an alarm buzzer will sound. After an emergency stop is released, the reset button mast be pressed. Hlalata less gil 1 PPE, 2 PES, ‘ALL PIPES TO BE COPPER SIZED 6 10mm ‘AND THE THICKNESS OF PIPE IS ‘TO BE Imm (QuNIMUW) ieman anon, | Forties sre TO SOLENOID VALVE BOX ‘| a | i] | | co | | eS | | = e—$—$— | fe L Uk - > ‘CONNECTION OF INSTRUMENT SENET aise | srwcroenaceiooes wwe Fp Sme Saas (lomaue saeaaura, ae (oPen) TO SOLENOID VALVE €0x (close) ot 10 COPPER PIPE as 0 (HAIR INLET VALVE (LARGE CYLINDER) nectth HS] CLEANING AIR VALVE (SMALL CYLINDER) ‘CONNECTION OF INSTRUMENT AIR PIPE FOR (NS) VS N3) DRAWING Ne, ‘O2iTS7A (SaETNo] JOF7 (Sloman aapaa wro, ae 2005-15-25] fsue] Now’ (toa Shim BEEge me Oy so ses cusarenon sas LN Dy eee late Vossen eee AWE 6ngi/ont LTED BY SESE meonesenmen® || oe BE Se ee a a ‘DUPTY WEI 9,600 — 3 e TT RBDET Tan ron oa one cour 7 ae sor Dera, gF pen oS RTT TE fa rae ee 3 3 HOW NEN Fat a Loca 1] 5 oe ee | i Tr ssi = eT Se vena LATE OSS ad) (2) REDD z wai Vs SIS EE oN ewes Ta paw sae no ET yee I BEF 8 es paw " |) FOUNDATION OSHEAD USHEAD. Votan aa re — i ie aE scenrmapeon i He . = Hara ‘BULK STORAGE TANK [useD Fo PNEUMATIC. CEMENT TANK uu susie so a a piste AEG pete _ beat rer Aamir amigo peoruce sae SECTIONAA © BNE eR POR vor: mm (g omnauNe aaa wa, Re PORT| ees a | | | tot one so! — ¢. FRAME NUMBER 2 © gaa a ta FORE fod. | f fos an recive NOTE: (1) FILL & DISCHARGE VALVES TO BE FITTED AS CLOSE AS POSSIBLE TO DIVERGING POWNTS AT BRANCHES. (2) THE VENT LINE IS 205mm HIGHER THAN THE FILL/DISCHARGE LINE. (3) TWO (2) STARBOARD LEGS FOR THE NO.1 TANK AND TWO (2) PORT LEGS. [ower FOR THE NO.2 TANK SHALL BE ADAUSTED IN LENGTH I ACCORDANCE HTH LEG & PIPELINES aa ‘CAMBER (SLOPE) OF TANK TOP WHEN TANKS ARE INSTALLED. ARRANGEMENT DRAWING No. (4) CHECK VALVES ON THE AIR PURGE LINE TO BE FITTED AS CLOSE AS POSSIBLE STARBOARD FOR BULK CEMENT/MUD TANK | —a7o62 SO THE MAIN FLL/OSCHARGE INE AND TO BE HORIZONTAL INSTALLATION | STARBOARD, frre 77 ATE] 2007-06-18 ae [SFlomseo> sapan ere, ext 22 | ‘STARBOARD. NO.2 TANK NO.4 TANK ORIENTATION ELEVATION NO. TANK. NOTE Wo (2) STARBOARD LECS FOR, THE NO.) TANK AND two (2) PoRT LEGS FOR THE NO.2 TANK SHALL BE ADWUSTED IN LENGTH IN ACCORDANCE WITH CAMBER (OF TANK TOP ON INSTALLATION. Snes [SPL — [Sue | — ser Ai LINE (Rae PLATE NZ IVENT UNE: Pi IReMOTE BRESS PLE NS[DISCHARGE LUNE | —P2|pRess.caUGE_(s100) | Né [AR LET LINE | ~P3_[PRESS.GAUGE PLUG NS [CLEANING AR [Ci [DRAWN PLUG N6 [SOUNDING PIPE [C2 |W-ineL SENSOR wt wana S1_[SAFETY VALVE. PLAN VIEW ORIENTATION & ee ELEVATION DRAWING He FOR NOZZLE OPENING ‘070623, [SET al YShimizd or ae or re CES — Seated) ta DETAL OF FIL, Sennen Cor tae ‘ONE REDD | : » DETAIL OF DISCHARGES 2 teray ™ nse SHEL. a oe es . Feo ” smc H| senronceuony 6 7 = # vse ts soe 26 b sca seysonay DETALOE FUL. COUPLNG {5 32 apes eee °B tb E DETAIL OF LOCAL PRESSURE GAUGE OSE TENAL 08 DETAIL OF CLEANING AIR INLET BS ‘vet RED | DETAIL DF MANWAY 5 Y ou ea fe i SE EPA OWEN D a one CRED A f 7 TANK TOP mpeg 20 DETAIL OF ARINLET EE tesa SECTION ¢_ ALR ILE fe BULK STORAGE TANK |FULL SuTa Mean) ? gq PNEUMATIC CEMENT TANK | G¥G0739 ee ousocsnn [RK osce ss. wna Ke A BRAWN Wa ig aS DETAIL OF NOZZLE & FITTING | 070624 ETAL ETAL. OF HALE COUPLING DETALOFHALFcoUPLNG = 7 ‘ fern | 07 "FOR DRAN Fa OaaL Pressure une (5) FoRLEvEL SBR . : “s 00-05-13] Wo ea RED FRR REMOTE pmeneute LeaD-cur [FT SECTION A SECTION B [lomau sapan WO. asad s1x00(ou"S0e) TE TL PSxTSRE —[RENFORCEMEN ig [Be] 1" STRAIGHT [CLEANNG AT UPE 5-4 [AG-SIDE FBR: [AERATION SHEET fa[ pele eLbow Jett —@0-Few5270 1s [24 [Tsar CPLC]HOLDER=35400 z[-1 [OONE=e10.0 SLOPE SHEET™ GDIE=A today] tyee-size _JoescRiPmon—waTERIAL i DETAL_OF NOZZLE ARRANGEMENT headed ted 3 [DRAWING No. 7 0512254 12 PCS EQUALLY SPACED @30" APART Coote Lee ‘lomo sapaa wo, 25 2 upper LOWER : 12 PCS EQUALLY SPACED @50" APART LS0x40xt6 10K~1254 FLANGE im 19 DISCHARGE MOUTH DRAWING No. (050406 [SET No] /OF7 $F omsuip yaraw wr, | 2007 7 Isa] Wo [aaa Y-Snirna 325 etree fatale Ht becom oe tae our side ara Faas a —_#0_____, it Barons — se atte a Fete z ete se tee Se peal STE eras eet Ht fine tonto fess fue al 2-11 [cover (BUND) 3$400 [126 a TH sent os asta a re FOR = BULK STORAGE TAK [SH No DRAWNG No.) 500 MANWAY: WOOOTIECC, SHEET Nae INSIDE_TANK SECTION DATE [2006-05-11 (Boma saponera, cae] now Sao Yah BULK AIR COMPRESSOR SPECIFICATION OF “AIRMAN” STATIONARY AIR COMPRESSOR MODEL : SWS75S - 57UP HOKUETSU INDUSTRIES CO., LTD. UNISLIP JAPAN LTD. 1 General Specification No, Daseiption Daa [Sit condiion Tn door ws Type z [Operation eondiion 1) Operation hour IMax. 24 hoursiday [2 Dust exists INon [5 Corrosive atmosphore oxists [Non |) Explosive thing exists [Non [ambient condition [Temperature lo- soe lalitde [Below 1000m about sea lave ltumidity IBolow 85% 7 |Applieable standards [SIS Japanose Tndustral Standards [JEM Standard of Japan Electeical ‘Manufacturers Association JJEC: Standard of Japanese Electrotechnical Committee Taspecton [According to manufacturers Inspacton standards, 2 Specification for Air Compressor Wa, [Daseription SWS SUP 0.59 MPa 1 Pischarge conditio, seharse Pressure 5.0 gem? [Temperature Cooling water tomp.+ 10°C 2 [Pico air delve 3.0 mimi 5 Preasure ‘Afmoapherie Pressure a [Suton condition RE — 5 [Compressed gas ‘Air 6 [Type Rotary twin serow, single age, ol soled 7 [Compressed RPM 6.150 rpm. ‘Gaetion por elosing + purge enteal + 8 |Untoard system Agia ae 1 [Oirenaiar Water cooled 10_[Drving syatam Direet coupling and sto-up goar T1 [Rated output Full load TSkW 12 [Power source ‘AGATBV #10% (50H) 1 Phase 13 [Air outlet size EDNG 14 [After cooler boll and tubo Type (oi cola Pipo sido ; Water Max. working pressure LO MPa (102 kgf) ab] | OU semeraion eet Hydrostatic test proasure 1.8 MPa (15.8 kyfem2) Type Spring type 16 alee valve Iprosaare TARP a (0.0kgHo BO) 17 [Dabetcation a ‘Airman long io 18 [Lubrication oi capacity e2L. ye “Totally enclosed permanent magnet synchronived motwe 8 phase OPH) (Output "75KW. 20 [Motor [No.of pole 2 Revolution 2.950 mpm [Class of insulation ‘Class F Starting Closed Star-Delta Sartor i [Dimension BOBS x 1,100 x 1,525 mm Lx WED, 7 [Dray weight 7.400 =) coe [Operation weight 1.450 kg (Air Glee Warning Lamp [Delivery aletemperatare (a eylindar hang 105) [Devry air umpernture at separate dischargo105C) [Delivry air tomperature at elindox discharge HOC) 25 Protection Ye cor Lamp & shue_ [lise airtemperature a esparirdachareo 1 mor (Over current Reverse phase [Prossuro sensor [Auto-start-stop operation 24 |Reonning moored free eect [instantaneously restarting function [Purge operation 8. Specifications for Cooling Water (Seawater) 1 [tema [Spoaiieations T[Allowable temperature forialat [Bolow 32°C 2[Required water quantity 115 Limin x 75m hoa [Allowable water pressure [oad MPa © Use good quality cooling water Teis dangerous to cause corrosion and sear in the cooling watorpipo ify use bad ‘quality coling water. Clean inside the cooling water pipe periodically because tho oceanic micros, seawoods and any kinds of shellshes may cling in the cooling wator pig. ‘They may eauso partial erosion or erosion of the cooling water pipe. Pay attention to the abnormal corrosion in soawatar including an ammonium and sulfur ion around a big city and industrial ares Ttis tobe desived thatthe P-H. value of seawater is over 65 (© Make sure to put the drain valve of the ccoling water on the inltotlet pipe. Be sure to drain the cooling water after stopping the machine ifthe marhine ‘will not be operated for long time or in wintor season like the eooling water may freeze in the pipe 4 Additional Specification 1. Discharge pressure 0.59 MPa (6.0kgtem2) 2 Free air delivery 130m8imin 3 Powersource -Maineireuit_ ACIS 50H Control circuit AC2D0V/ S0Lla 4 Selireiance stating board (with controler) * Motor stating : Closed Star-Delta Startar + With meaivar tank temp, gatge + With AC Ammetar + With cable grand (wiring) Seaveater cooling Cut off water check function Motor Seawater resist treatment + With terminal box + With space heater 8 Service air outlet type + Suitable for JISIOK 80 flange + With valve for buttery typo (0A) 9 Bonnet loss 10 Painting color: Munsell No. 7.5GY74 41 Lubrication oil: Airman long life oi 12 Instruction book & plate : English 5 MOTOR FOR COMPRESSOR 7 [MAKER TOSHIBA 2 [TYPE TIKK-FCKLE 3 [RORMENO 225M 4 fourur T5RW. [NO OF POLES, 2 6 [THPRMAL CLASS F (SPE 2550min-] 3 [FREQUENCY 50H 9 [VOLTAGE 415 10 [CURRENT 134A i Ls GACH ufpanwa — ES Sees 72 [ISOLATION T Pad ; ‘SEA WATER RESIST TREATMENT 13 [SPECIAL PROTECTION Tarr PACE ETE 6 RECOMMENDED OIL, FOR EXCHANGE BRAND. IMOBIL, RARUS 424 [SHELL CORENAOTT RZ [COMPRESSOR OIL RASZ mM oh fk ROR PARTS LIST =e 9) 2 #8) 6 &) & @ | # a] 2 = = © apa) we a MARK NAME | TYPE Pec. |oty| REMAR MARK SPEC. (9 Ty) MAKE REMAR. 52,42 |MAGNET Sm, |S-NOBTN JACZODY 2a jz |MTTSUBISI) ToROPICAL TREA - _ —L_ = soayea JDALICHE E| et acrer sw. |s-wesyn Feed |e eee eae |e 2exPANDEDSCALE a emer ee macro. lesan tpcaoor nas fy TSS roeorca Ta a0 Femaa er oo 1 pie — » ft fnew ERA Lac evs nce [wri coven [SERGE KILLER |UN-Saat laczoov fe ee [ramewo were |escs-rer —_[ACiOo~240 foment | —_| - fener [rav-a0 amen F020. 07 ——— 5:20. 220" et hao svi [esina9 1 [asa hes eas rorver fovscoo-ae |aoora 1 frasuca fore cover a _ lsooret | Parian | onan oo TREATMENT ee coat fr Jasrar Pao. 40.407 Fi rican Savor [ese-niea, —_|-0e~a06 1 fog oTT Ba 5:20, 2a = 5 la eas sumer fovscso-aeez [5:20.22 | feasca farm cover [las PS TIO SH aoe rman TY tan eae is os REATWENT | vio [tame (owee-eat-aaw [aca ware ——_[1_|ruya__| wim over = aE ess tu ite rs at — fasrereT fin — [pa op tr : ~ tas ease —[aareas i fron Fe 7 se lar jawecron ——rias6-1 Tae — [enter pasar sf — jaa —— footer TSE a 1,4, RY [RAT [re cz {5 fovea - re. [eae 20 |e : |scexer ves a | earecren [ivan [ore t Pac-at 5 lowe 7 es Se mee co Tse — 1 — en —_ ee eis a ifaw fear one eames asa asto0 ics iar —|— —joaaraario | F iw 007 some |x Jeunon | ee pe teehee fe { ss errs + joven Fuse it [accoor ak 1_jr__ | Fa poaes [foe lt 7 crs as TROPCAL T formas tau facoone fcsancsmieon |i [SRE a : Foe Te 1 5a |, remo forte WET FOF ee pax 5 frm a mont as [orceae Janos sta |v t RI RRA SH ax eles] ee lone JON ao aE — wonerau vaavsTaice 0 Oro ° ore eet = a2 SWS75S-57/67 UP 7 bs 9 7 fiver] BREE R27 ER, gay be at mu ha Ve = am Bae a co ‘ 2a eI & aa seem EEENPRRce, sw F PEpsTAnce, Pee Eson 6 a ROKK 4 BEE ese hr | 3 af Been ane vy-sieyt oa : THERMO METER EATER 1 eepsasene =p Seice nesre coh son ie oro J | one sot] aor ke Tee eH [ee eles, | ee ae meet stil ee 2eeE IE | fa ute fee ble | TEE Novas PRETO RESREOOAE 7 Be] SER a ahbe | se | SWS75S-57/67UP aie | | me fis-2-e [as] 3a eames tte [nn || ncaa eneueeneea ee até: Sue [STAR-DELTA STARTER | ?iftomene. | 46230 25321) —T3=G13 7a) os RENOTE CONTROL PANEL, ass : 8 FBine stowan Beene Frome uN Ra 2 ONAL CReMOTED SxtaUN orf st58 fee SEB stowa ¢ ates EEZunc stonat ° mssens TERE sccua E age SERRE on siowat F 6 4 1 J E = | att. | TER Sit a ne ts a en 3 ETT RENET | [BiG aaa ear] AS, won | SWS75S-57767UP ese Shute LeU] Bet tt insist | STAR-DELTA STARTER| Sattowane 03-Gi3 (a) REFRIGERATION AIR DRYER PRECAUTION FOR INSTALLATION As the dryers are air-cooled type, it would be recommended installing them in a cool place as much as possible in the room, Besides, fresh air due to draft fan shall be arranged facing cooling air inlet side for the dryers. NOTE: The cooling air suction side should be placed away from bulkhead or any wall by at least 200mm. UNISLIP JAPAN LTD. TEL No.: 81-78-361-0480 FAX No.: 81-78-361-0323 E-mail: unisiip@pearl.ocn.ne.jp ae tt tk & Retrigerated air dryer sevemeanrons | re 7 Frat Ka Tis auoaine, orm pac aN 2. ig snaton | aa conse et. cone Lr coer errs Ae pang conten | Asn n/t nance) fou we kato 2 —Lrrt—‘“Cs_O__OCSCSsS : | camel st OPERATING PANEL —— Sree Please mark (/) the option aark 31iQetion classi tieation TF] sesitiee ester FOG! syecit ied vations DW} Seeci fications Te Enel ioh O21 vs saneeiate EDK2T Air evens, snore DME Uover-tior severe TWiT conse fuse rust-sreel D0} oven 4 CVI! Conetetion ehatoeraeh [32:Vottace options E200 (Standard vadtevel 220 [O20 [0240 [O00 Wars [eso [460 [0 +00 To [ane EVEL ERGOT nT [OTOP To[AIR PRESSURE GAUGE [1 [omar LT [TRANSFORWER 1 [apron 6 te] PonER HOLE 2a 15 [CONTROL BOF i 14 [SERVICE VALVE 3 13] FAN BLADE 1 12 [FAN-WOTOR 1 TI TCONDENSER 1 To [CAPACITY CONTROL VALVE] 1 [RE TGERANT PRESSURE GAUGE [1 [aE @-[ COMPRESSOR 1 T [HEAT EXCHANGER 1 @[WATWR LeveL sensoR [1 5 | SOLENDIO VALVE 1 4 [MANUAL ORAIN_OUTLET [1 WUT 3 [ORAIN OUTLET 1 2 [AR OUTLET 1 1 TAIR-UNLET 1 Bi] 6 a 4 feeeee eal as vw |" oktr * [peat oF] Rowan lax I sreeno| | Ae [ex a4) REIGEANID ATE GNVeR evens GT GENTE BSR EWS | GF /BS/FE) | emma) Ns ide STRUCTURE DRAWING Maat | "evita | act [operon INS LE jb ‘other .tmn] Boxe [wooe | GT 70 No T.HASE| Scase [wet] S| 3/- Jet [hen | hve GKD Corporation = S00 LEVEL SEH WER FLT i,t A [TC03] TRANSFORMER Hae) ls HUGH INDICATING CANE ts \ iOs[ INDLCATING_LANP——— gue LOATFNDICATING LANP — i 8 ‘a | i108] ND LEATING LAMP Ce oP rosa Bi ' q WL06] INDICATING LAMP 1 = pT = q INLOS] INDICATING LAMP. 1 Ir a! Ie Tera Bal : | Loa] NOCATING LAMP TIRED. ! magoCmataiia | HES om ATING LANE (Preto, sang cl! AM use on 31} nf | RATURE FUSE i pate Tk oe ee i Holcise | me ! DS FUSE fo. wld 4 jo HBETHE \aenonen BE ! |fubt| TEMPERATURE FUSE [1 | 1310. 0.58 0 esa 4 | : Isani]MALN. CONTROL BOAD 1 = i oan (SH 1 | SaOR EBSEASKEY*RZEE B4, 1 y wf] tt ppeernet i, torn afNOE CHANGE 08 STEEL Bip | snsa 3 Wo WAIN SHITCH oo i 2% i if FAN CONTROLLER oun ae H | START SNITCH 1 i i A fi, | STOP SWITCH i . ramon | || ORAIH TEST SWITCH i a HGH PRESS swiTeH [1 [ SOLENT TAYE aR AT HIST 1 catare | ua i 0 TRANSFORMER. im FITY i pa _\ TRANSFORMER i Ho7iér en sauce Poche Morteteraceowracssoe—P Pee] oS a FAN-WOTOR 1 slay fara 01] ELECTRONAGNETI¢ CONDUCTOR [1 SOSH THPE ae AMORTELECTROMAGNETIC CONDUCTOR] T AOI|THERWAL RELAY phease aark (J) the option mark, riewte slat ternaat OID gor valians Tart, &D0 sot oserate-whide § siautes (HRTHERALRELAY———[-- enerivabensaa rier Set uy svitenes SMUD and SAO a2 Tullavian alter ston this dever jvai[TeMPERATURE SEWSOR | 1_[ en Pom Je shee theacer is qerted ly tenet contrat, eenvee the eastart srevention AERITEMPERATUE Senso LL we OE | Seve ates ease SHOU ON on cirevit is operated SRA HTERRAT SeeeeeraT Tt | OA seaet vet ont Te Epa \—.02 footfeareR CECE sense | foe | 1 H2! $US nameotate LGoeration sinnat is non voltage a-conlact.. rLarm ag - oe tent sansiniarnenincested — 3] #02? SeRESEIPE| Soe rei (Dperatian:03-0¢ edose, Alaen'D5-07 elcse, Dev sujet — [OX Learn TMI conser tute rust-vraet Seeley = specN} a Coattet even: 28N4/1 190 266.8307 ee TET AEITY ATE TENT Dyte S.fleactivate the dryer ianeéiatedy af ar vover wank | “eevision | pare ELECTR fant 1m fecovern If faslantaneeus poner (atlare Ta ; z aietodtune ast leas ceases lean ae Ren [hovel | G70 es Mao, reactivate the (rrer 3 ainutes tater after jae Gare [Orso [One [aes [oes over recevert if Taglaslanenvs power Hitare T.WASE| Soa 4e awe] 9 [3 |= a #40 [0460 [D480 is Hess thon 2 seconts. z FY BR weet | two | tev |e ces CKD Corporation Te VALVE AND FITTING \Vettical Down position Horizontal position Note: Butterily vaives can be installed on the pipelines at any position, In case of 5" butterfly valves, horizontal installation is highly recommended than other positions. If not available, down position is better than upright position, UNISLIP JAPAN LTD. TELNo.: 81-78-361-0480 FAX No.: 81-78-361-0323 E-mail: Unisiip@pearl.ocn.ne jp ra © so-so nce op sigs Pleo. $180 3 mae i - 7 [auro-oRaw he _ q 6 ve ea saP ee 1 [uno rare fist» [57a rar courune—[ssac0 [2 | 2 [pre 38-scr ssio0 [2 1-5 tok=so rane | 000 | 2 ESRD DRAWING No. WATER DRAIN TRAP ae FOR COMPRESSED AIR SUPPLY LINE [Than] JOE lee DATE] 2002-12-08 [yma sara ura, 2 ex J IY Shimizu eae hie [SIS SK TIS Era frenl an 4 |B ELST KL CIM IN| P [attire Pert ea aCe Pn | hy Okey 2 [50 | [9a 4 ios [-« [os [wa fico] + [19 mie ) Exel es | — [ios iso] + [as [wa]iao |< [19 mie a0 [eaaliee mil ee [7 [ia [salts aeojaecaasa| as | 4 [a5 ws [150-8 [19 [wie |“ soo | — five T reso fis fms hve bi [ue 25 zal iee zea] 90 | a6 [15 [aralie [aaa jae-i0on [200 |e [a9-ms [210 [6 | ex [neo] Tis jis] [aio [220] @ [19 [wis [eo] 6 | 25 [neo | feoo | [esa TE =“Jesole Tea [nea [eso] 12 Tes [neo Nores 1, § MARKS SHOULD REFER TO SPEC SHEET, [OPERATOR ORIENTATION 21 SUPPLY AIR INTO PORT” b", VALVE SHOULD OPEN, (PE waS=a [RSC SLOPERATING AIR PRESSURE:0. aMPs, rr 4IMAX, ALLOWABLE PRESSURE! 0, TMPa, CARRE HOLE ~. teu " Mave 1 na use ae he «OPEN? CLEANING AIR INLET [NS], eRe 10 | Tne Ton — [eae | ape SP, WASHER 1s0sa0e || WARNE Some [susa06 | —« ‘in swiTon wofrro | rar Sremtsnen——— [smuio7| =] rene HEX, HED, OUT —[s8a00 [a] wren couwecTon ——[sese [ier aes [lef anaontr sess [4 ; if aig acruaToR —faacie-[ a} | a © [opr 8400-3] rea [Col se.wnsner — sumer] a] rane | + a [Cal wax, weo, ott —[seaoa [a] wren=< [Cristea pin ——fsisa0z| a g—_—© fo. RIN ie [a GOO sf Pin usa | 1 « \ —® a) Ste suse |r 5 H a] sear fae | € af oise aaa 1 fe ‘aaa reoest |r << ____JRol pe ScRiPTioN — jure sas Rewaaes i i aI NIIGATA ENGINEERING cO., LTD) HMIAVA ke UITERFLY VALVE Nip 2-6 Sa e s A IR _ACTUATOR TYPE ASs' y [vio kee RATaO ble] JASS1—003 5 | Plea SE r ae ee pent | AL BL DEF GIHIT I} KIL IMINI P| @]R henelcrt npr pee] n | h BOL le 2 [50 | [35 [s2-| 00 [76 wos | 4 [1s [mie feo | 4 [19 mie Eia[ es] — five fee [ae [7 [es igo] [1s-[mie [ao | + [is [wie] | Ceismp—ye[s [oo [evalies [re [ae hiee|se | o2[ aril aa | re [13 [wos [eo] aaa] rsojrae-aeod ies] + [19 [mie [1S0[ 6 [19 [me] 1 4 fioo | [14s [103 | si [152 [108 65] [19 [wie [175] 8 [19 [me 3 fies [see ios [ies [4 ise [ise | sa] evzhos | 06 [18 |oos| | 2aa| aay] rovfrae-1o0H 200| 6 | 9 |wie [210] 8 | 23 [neo] 83 6 fis0 | [aio [184] 54 [16s [138 220] [19 [wie [e40]_w | 23 |we0 [200] Jese) 200] 60 jeoe]177 200] [29 [neo] 290] 12 | 23 |we20 ae I 4 Notes fe 1. { NARKS SHOULD REFER TO SPEC SHEET. St 4 OPERATOR ORIENTATION BISUPPLY AIR INTO PORT” b". VALVE SHOULD OPEN, \ WEE] mAS-a [—nas-C 3, OPERATING AIR PRESSURE: 0, 4MPa, oh 4, MAX, ALLOWABLE PRESSURE: 0. 7MPa. el ba = [ATR TO OPEN ¥ ISPRING TO GLOSE| CABLE, HOLE ra sare 3° VALVE IS TO BE USED FOR FS Ponzi” AR INLET 4 aa ToT [aoe eee = ‘ap ea i[asise Ta se, WASHER ——[o0sa04| 4 Ta [-WAGHINESeREW[sszo4| i= b To] LNT S¥VTor Fara [1 wre] (*, Ta] HE, HED BLT —|ost0n | «|urance KA | See x i ia eowecror [ssc fr a 3 - : vi [are aerunTar [were [+ a ‘op wr sb [ = [area n-BOLT a semen [svn] «wren : neWOLE [HEX HED, OT [asta «wren © $ 4 r[setnat PW —[sisa02|-=] | 49 ce 3[0.8INE ae [3] QOL SPiN suea03| 1 < 2 «STEN sus403| 1 a ; a[snat hat 2 [bise re ome | i 00" renaso g 44 S | DESCRIPTION — asa ERAS : NIIGATA ENGINEERING co. LTD HAMA a ae oe tat SUITERELY VALVE Ni5 2-6 omen : > F “AIR AGTUATOR TYPE ass’ y [Won 2 ne mses pS SS 1-004 I Ton) tea vid) - ig] Peon ad [ate et aes A i = 2 | 1] of |g comes 12 | as eas Weng Cate conector (01/2) Ceti Axeplarea 48 ~ Y2een ol toe 6-19) 8 ta-00 | = | “ta-080/100 | BoUNN Fae taco [| eas COMETOR Fics [SOTA WOON PRE x [cower Ga) wun RE ee 36 Te ear eT eons necesséo 13] FESR | sussoe a] ae Aly [Ce [ene cca Tp ve g D) PE ea sone OTS | 3) [ef eat 1 4 [aaron oe my | 7) [ef cover I Tse nora] || Te|SeSenrton | aneracs [ea] — RO STRSTR [REE] TE 1 TE SaCH Box a [wnte-e[ er | T _SraveTuRAl'/ OUTS€ prams SE (2d NIPPON VALVE CONTROLS.INC. LINTT SUITCH 80K: To BE FITTED ON EACH ATR CYLINDER [REVISION Pa PME, | Pe are [whan r-otn i@7in| oi/0s/0| tt | 8 ~ 00-08 19 =08390-N6 SEH CJSTaINLess STEEL [susaes @ ee ((59) as 165] NAME PLATE. 1 © ri = t eee (a) SL Greer ‘afeantow sTEEC oy ee scemim suewmour sieznonn alge S| oeatee ee — faa = F ci Pe ee pts © A = ss [epAceR 1 [ennaon- STEEL satan 2 so" iy eal = = | ~~ Le Ue = 4 size | [Piece or] — fer zs T BY a awe 7 | as _| 100) [is] me Tal 2 | 65.5) 5.5) 9.5] 128 | 54 fvo7.s| = THICKNESS UTE STANDAFS 20] se} 20 wu = | * 28 | 54 | FIGURE EHH = 0ST Stat ar herbs fae opp ea BE Grebe farses star] fam RG VLE (215 201-80) whal a = va me alee oe ee au va wi euecraze wre efoe aes 7 ‘apa = ate eee] fs : z é eae "845-080036 - sete Pe beste a = coy EyeSeT AETATOR SIZE & REV=-00 _ fast oaretar KITZ IsiTZ CORPORATION i in'79 oun ProgucTs, 4 i i pea rite “4 | tar eo 1 {aso Sone 1 u — option! Pace soe PAR co ott was ss ass o cette, SHUT CIMLT S¥ToH OPEN LIMET SHITCHCNON-VOLTAGE FULL OPEN StONAL> SHUT LIMIT S¥ITCHONON-VOLTAGE FULL SHUT StOMAL> ) A NoTOR AND & SPADE HEATER BECOME NON-ELECTRICLTY AT THE {RNG OF AMMUAL GPERATION ANG ACTUATOR” OVER RE (4) WEN THE VALVE WOME TO OLOSE DIRECTION, RESISTANGE VALVE BETNEEN TERMINAL AD, 14 ANO 16 HILL BF DEGREASED, [- EXTERNAL TERMINAL [ MOTOR VALVE FOR THE AIR PURGE LINE_ KITZ ELEOTRIO ACTUATOR KELMO __CIROUIT DIAGRAM aT Sa exo-oy [wwe] gos-080243 eau oYfe ter] REV-O0 (afte tar I5IT2 CORPORATION TET KITZ 4-019 24s ag 2156 i 2 [ulS 1OK—50A FLANGE | FCD&5O_ STRATAFLO CHECK VALVE | BRASS “a NAME OF PART | MATERIAL [aTY. NOTES - ORAWING No. 0007148 2” STRATAFLO TYPE NON RETURN VALVE ISHEET No| /OF7 \ATE| 2008-03-24] (SF wise aapaw ura, [s2|_von Leet (oeoo|¥. Shimizu FOR AIR PURGE LINE 1 Z “Ts Telole[rlelali |e aera OPEN [iat ee] oT WO ke 2 [se[ tig) se] fa a1 [66] Fe wala eb epfwiey 3 feats ee Livrf es ae [veal seal ise] «| is fweel cao] «re wie So se fatal est 96 [oe [zal 41a [yaa] tea) es] «vo [wel iso] Tefal | + [ieo| soo] 4slioa} si [rsa] i0g| co] tox|reof es] [refs 5] 6 Tie [mie[¢ 5 fas] 314] se]zel se isa] 22] «0 fvea{seofaoo]e | v0 mel tie | [a3 [r6| 1-7 [igo |seokeralise! se fres|s6icolior|zeolreo! etre wel feo De [as agole NOTE # MARKS SHOULD REFER TO SPEC SHEET, OPERATOR ORIENTATION Tee Nwi-e Da-e me me PIPE wo lo aN | cuosd : ha 7 = (CWARRL.— Ar ore 5 exase ev0sele ose TEE Te t= F aS aFEN [sus : N ‘OPEN Fok close “LOSE clos Twat —— Fase aI eae vane [rs wer naar — [eves ta [aee-re0-s0eT —[sse0e 13 ALAN Vise — [sgane| 1 fia|'Seueoc pin — [sear 1 Ti TaROT Toe PATE fss984 io SPRING sae] if — a] GLP coo] 4 HAADTE see [1 7p seraOL Bu — [sana a — efor a spa fovea a] sien seer [ aT SEAT ian aos reer Teor cea SPRING. BOLT “SUS ae] OeSERT ATTEN TARTS " TT fiicara encineeeing co. Ur f i pee a H “AUTTERFLY VALVE WIS 2'=f 4 a {-APTEVER HANDLE TYPE ASS! Worst fevisions eae] J M1 S| ~O lect fan uu WON eavai/ae | yl ai, REMOTE CONTROL STAND als |_ SOURCE AGZOV—5OHe aa a | ome oxaaa wo, Note: The panel is to be installed facing tonard aft. RULE | ABS [pPeROveD] A warsiah PATI TE ome [18 ane zor | EA eager ram [wore | cecxen |. suwtau DRAWING NO. 0706-031 ‘APPLIED RULES: & REGULATIONS BENT aS, JIS, eH TEMPERATURE 450 rn TV Ce] » [eam LETTERS: ENGLISH WHITE GROUND WITH ENGRAVED BLADK LETTERS) CAUTION PLATE MATERIAL + AORYLITE LETTERS ENGLISH: CITE GROUND WITH ENGRAVED RED LETTERS) CONNECTION PRINTED PAPER ENDLOSED IN PLASTIC CARD CASE DIAG, PLATE wT St TERAINAL SOLDERLESS TPE ANP ‘SPARE PARTS WAKER STANDARD ABS RULE & REGULATIONS FOR! OF LIST JER STYLE BOX : MADE OF STEEL STEEL TYPE PAINT COLOR = 2.867/2 SOURCE Ho 220V Soe 19 centacn | A 100¥ woutase | 0c tv Le 2005/13 SOV FE Uy soa TER WIRING [MAIN CIRCUIT STP CONT.CIRGUIT SYP ULIO15 REMARKS a = a a ekaet MvemeMBUrEM | Spe pie ir OusaIN eens coe SPECIFICATIONS 0706-o31-01 [os coLor DISCHARGE LINE — 10R5/14 FILL LINE — 7. 5R8/4 AIR LINE 1 B/14 VENT LINE — ByRT/12 COMPRESSOR — 106v6/6 | TANK — 1-8. 0 BACK — 41.0 EMERGENCY — 1 SRA/ TA Es a la ms eka DRAM T HANSHIN ELECTREG MFG,CO. LTD. GRAPHIC COLOR 0708-08124 co FET ® precainn) e e © BULK HANDLING SYSTEM OA BULK STORHGE TANK S | mths reg fu s7orabe sane wo] tentereore wor 192800 Gaaeen ASS lela Ll taal th pn ‘isimewacen tose Alale| lela ‘almemmeral oom Nit aldtnewee ch spy fue Ela “aireenaeesey wea wors93av03 ‘aiseemere 3) lle alala| woT1934409 ‘amawaeen were Lele lala aireetareeee woe allel ‘Darema sere lale Iclq dale lela WOTLD34409 | Wors934N09| Tiasewaeene ase wouL924n09 wor1934n00 earemaies eee = 1fleba non TeRUIAL ii agemtewe ESSRE. ous eRQATIONAL SHIPBUILDING & TRADING co Lo ‘SHIP Na HULL GNGO739 ‘SERVICE SOLENOID VALVE BOX AC1OOV-50Hz FOR BULK HANDLING SYSTEM HANSHIN ELECTRIC MFG. CO,, LTD. OmNsRI? JAPAN Ara, RULE | ABS [arPnoven] A waTsunnca PAT are | 19 ane coor | AMY | 2 sare ram |e oniro | cnecieo | ¥. shimizy DRAWING NO. 0706-032 7D a a hake | ae sn ‘Sram | ve ween Pan) a a ‘a wt 2 Te a Pe hor ca oe] ow [a a cA eRe eR Cena Ba (WHITE GROUND WITH ENGRAVED BLACK LETTERS) Ta aE wr TE ‘Ein: Coe as nor Tae |e no oes 1 TE ie Tenn |e THE Sn Tt WS wae ve a com | er ie a Fn TOMER WIRING WAIN CIRCUIT SYP CONT.CLAGUIT SYP ULIONS REURKS x x la 1a testeat maememmurrmn | TS wee ane ectnioties Goer SPECIFICATIONS o705-032-01 |as TEETH as MBIA BNTTING Sesame Roee lcle lele et Bt 00000000 00000000 00000000, NOTLO3NNOO. sas | Wo wee lal Isle TT CONNECTION aan SeRNO Tal ReRRETR lele lale BULK HANDLING SYSTEM MAKER'S RECOMMENDED SPARE PARTS UNISLIP JAPAN LTD KOBE, JAPAN TES PER SHIP WO. SPARE PARTS LIST FOR Use or ucorss Qui PENT BULK HANDLING SYSTEA 1 (UANTITY REARS ren NAME OF WORKING OUTLINE No PART en | pee [SPAR| SET | vEss| UuseD FoR 5° 1] VALE sear 5° 1 [25] 3 | acruaTep & wawan BUTTERFLY VALVE 2| vauve ose 1 fas] 3 = ditto ~ 3] norze Tee 24| 06 | 24 | OR BULK TaN CLEANING nazzLe 4 | Lever sensor 1] 4] 1 | row wi-teven sane ha 5 | Limir suites aox fe} 1} as + | FoR VALVE opeuING InoLcaTION FoR 5” BUTTERFLY VALVE WITH 6} se KIT an rfl s FOR 3” BUTTERFLY VALVE WITH ye ea ‘AIR ACTUATOR ee FoR 3° BUTTERFLY VALVE WITH 8] SEAL KIT.) gig acruaror seeing geruan) | 1 | 4 | — = | = | fosea amen aur ware a | sso wner | + BAW AS ME MFRS MANE WWISLIP JAPAN LTD Rw. HO Serer Sir no. | __SPAE PaRTS LIT FOR Use eRe fEvOTE CONT. STA corse | SBOKE com Sta & sux moun SST 1 unite ROMS pre] sas oF ‘OUTLINE: WORKING vo] pakt BER | ek [sa ai nse {== aaa 1) etemenr =H ajaye HH 2 FUSE f{E=A Ts i vet ‘ELEMENT 0. aye aA a) we “Toa se] 5] cma avi aus = I fain eee. “| a Ga fefeye] i Le [pane [aT seer 7 ¢| Sno co TLE D1 [muni Heh, 1 Wet TEL reine sawycraTon r oy uy P Thrta Ee @ Tt [1 [weer ine 10 RELAY TET [a [rusecncrocy, son in 3 aha Lr [eon 2 ry we [1 fat [ace qunon TIMER MaYH—2 8 my oe a [ef [eve ee a 7 alarle | Bune we L 8 ee) z|a|2 aie JT as a atan memanyrm | an HANSHIN ELECTRIC MFG.CO. LTD. eee o708~pai—22 | BP REET PET SEIS PER SHIP WO. SPARE PARTS LIST FOR use ihe REMOTE CONT. STAND & woos | Senor waive aor BULK HANDLING SYSTEM 1 uamity RENARAS rex] name oF — cana No.) PART wer | Pe sea Sr |vess 16} so.ero1o as[ ts 1 | svar nf o™ 44] | siezeo PRESSURE tanate 10| "aoe air}a seta te] PUL we 1 | run gees sur ever zo} PUL Le 1 erie sveen ree 21 | SPARE 80x i 1 | part. cotor rare ioe iz x JJ a a vestett meeamenmerern | TT at EUR ELereeieearcn SPARE PARTS LIST ovos-o31—23 | sp

You might also like