You are on page 1of 2
Certificate of Calibration Date of Issue 13 October 2021 Certifieate No + UTJIPIES-MM/211001476 Issued by UCAL TECH’S (M) SDN.BHDycussy) Page 1 of 2 No 8,8A Jalan Shahbandar 2, ‘Taman Ungku Tun Aminah, 81300, Johor Bahru, Johor Darul Takzim, Tel: 07-5541466 Fax : 07-5542466 Email :es@ucaltechs.com ‘Submitted by Conmax Resources Sdn Bhd Date Received 13 October 2021 Lot 343-1 Jalan Pegerang Sungai Rengit Job No 4321100312-004/211001476 81620 Kota Tinggi Johor DocumentNo 20RI7:MASO 1 A A005 Instrument Torque Wrench Model ‘STMX3100 Manufacturer Novatork Serial No. 2 ARO40983 Instrument Condition When Receive 1. Physically in good condition 2.CustomerID-—: NA Calibration Status : Calibration Date 13 October 2021 Requested Calibration Due Date 12 October 2022 Recalibration date requested by this instrument to drift out of Calibration Venue :- ‘Above Mentioned UCAL TECH'S Calibration Method : Instrument Condition When Returned : 1, Calibrated and Test Serviceable Environment Condition :~ ‘Avg Temperature Ayg Relative Humidity 235°C 554 15% customer. The user should be aware that there are a number of factors that may caused libration before that specified calibration interval has expired. ‘Address and refer to Job No. This Instrument was calibrated using the Calibration Procedure No : CWI-GM 004 (Issue No : 1-0-0 ) BS EN ISO 6789 :2003 Instrument Type Serial No. CaLDue Date Cal.Cert.No Torque Analyzer UCT-103 10.08.2022 UT21/NS-Ha024 UCALNMIM Standard Weights, UCT-020-030 24.08.2022 ‘NMIM-2954-M-20 NMIM ‘Thermohygrometer UCT-366 09.03.2022 UTHBAR/21C/006 UCAL/NMIM The Standard instruments used in this calibration are traceable to either the National Standards maintained at the National Metrology Laboratory, SIRIM Berhad or other recognized International Standard Laboratories. Calibration Sticker No. 0312-004/01476 Measurement Uncertainty Refer to calibration data, Coverage Factor k=2 ‘The uncertainty calculation is based on the ISO Guide to the Expression of Uncertainty in measurement. The expanded uncertainties are based on an estimated confidence probability of approximately 95% factor of k = 2 unless stated otherwise ~ Technical Manager > Quality Manager Approved Signatory and P Manivannan a/l Subramaniam Bhavani a/p Gopal Krishnan and have a coverage x LEE Approved Signatory Select () Zz ‘The uncertainties are for a confidence probability of approximately 95% ‘This cerca is issued in accordance with the measurement capabilly of UCAL TECHS laboratory and is Taceabiiy to recognized national standards and tothe units of measurement realized atthe corresponding national laboratory. ‘Copyright of his certificate is owned by our laboratory and may not be reproduced other than in full except withthe por mitten approval ofthe Head ofthe Laboratory. Certificate of Calibration Date of Issue 13 October 2021 Certificate No UTJIP/ES-MM/211001476 Instrument Torque Wrench Page t.2 of 2 Serial No, £ ARO40983 Calibration Data Force Measurement Verification -Clockwise Manufacturer Range: 20 N.m to 100 Nm. Calibration Range 20.N.m to 100 N.m Resolution 208 Unit : Nm ae ‘Applied ] Measured ‘Specified Limit Tnstrumental ‘Measurement - Value Value Tower Upper Error Uncertainty 20 20 20.5 160 24.0 os ca ol Nm 40 40 40.7 36.0 44.0 07 a Nm 60 60 60.9 56.0 64.0 09 eal Nm 80 80 813 76.0 84.0 13 + 1 Nm 100 100 1018 96.0 104.0 Lg. eo] Nam Note :- 1) Instrumental Error = Measured Value - Applied Value 2) ‘The specifications / tolerance provided is not regarded as being part of opinions and interpretation 3) The above result reported is only related to this item 4) Customer holds the rights to decide the usage based on their own specification / toleranc 5) Specified limit reference (s) to manufacturer specification Calibrated By : Firdaus Review By imployee No : BOSE Muhammad Syafiq Misban ‘Tho uncertainties are for a confidence probability of approximately 95% ‘Ts cortical is fesued in accordance wit the measurement capably of UCAL TECHS laboratoy and is Waceabaiy to tecognized national standards and tothe units of measurement realized at the coresponcing national laboratory. Copyright ofthis cortitcate is owned by our laboratory and may not be reproduced other than in full exoopt withthe prior writen approval ofthe Head of the Laboratory

You might also like